INSTALLATION & OPERATING INSTRUCTIONS INSTALLATION & OPERATING INSTRUCTIONS EST. 1947 1-800-226-8710 / [email protected] / www.montalvo.com Technical details subject to change without notice. IO-U-series-US-02 © Montalvo U-Series Under Pillow Block Load Cells General Description Montalvo’s U-Series are used in conjunction with pillow block mounted bearings and shaft to create a durable and precise tension roller that’s easy to install. With an IP67 rating the U-Series offers an extreme level of protection and performance for applications in harsh environments. Principals of Operation The sensing element of each load cell consists of a pair of semiconductor strain gages configured to form half of a Wheatstone bridge. The load cells are excited by a stabilized DC voltage from an external electronic control circuit. When there is no force applied on to the load cell, the bridge is in a balanced state and hence the output signal will be near zero. On applying force, due to bending stress on the sensing element, resistance on the strain gauges change. This results in a corresponding change in output signal from the load cells. This signal is amplified to suitable working levels by the external electronic amplifier. Installation 1 It is recommended that the tension sensing roller be the middle roller in a tri-idler-roll assembly. The wrap angle around the sensing roller should not change during the installation process. 2 U-Series are mounted in pairs, one at each end of a sensing roller. 3 Both load cells must face the same direction (observe cables as they exit the load cells). The label on the load cell assures proper alignment with respect to resultant force Fres (load direction). 4 Use caution when selecting and installing the bearing bolts. Bolts that are too long will damage the load cell. Make sure they are the proper length (see Dimensions). 5 Wire each load cell to the controller or amplifier using shielded 4 conductor cable. The cable will require a female 4 pin M12 connector at one end to connect to the male U-Series connector. 6 For additional wiring, calibration and tuning, refer to controller or amplifier instruction manual. Fres bearing roller web web Product label indicates allowable range that direction of load (resultant force Fres) must fall within. Guiding Rollers Load Cells (note that connectors face same direction) Sensing Roller Male M12 Load Cell Connectors Female M12 Cable Connectors Shielded 4 Conductor Cables to Conrtroller or Amplifier Pillow Block Bearing Pillow Block Bearing
4
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: U series-installation-instructions-us

INST

ALLA

TIO

N &

OPE

RAT

ING

INST

RU

CTI

ON

SIN

STAL

LATI

ON

& O

PER

ATIN

G IN

STR

UC

TIO

NS

EST. 1947

1-800-226-8710 / [email protected] / www.montalvo.comTechnical details subject to change without notice. IO-U-series-US-02 © Montalvo

U-Series Under Pillow Block Load Cells

General Description

Montalvo’s U-Series are used in conjunction with pillow block

mounted bearings and shaft to create a durable and precise

tension roller that’s easy to install. With an IP67 rating the U-Series

offers an extreme level of protection and performance for

applications in harsh environments.

Principals of Operation

The sensing element of each load cell consists of a pair of semiconductor strain gages confi gured

to form half of a Wheatstone bridge. The load cells are excited by a stabilized DC voltage from an

external electronic control circuit. When there is no force applied on to the load cell, the bridge is in a

balanced state and hence the output signal will be near zero.

On applying force, due to bending stress on the sensing element, resistance on the strain gauges

change. This results in a corresponding change in output signal from the load cells. This signal is

amplifi ed to suitable working levels by the external electronic amplifi er.

Installation

1 It is recommended that the tension sensing roller be the middle roller in a tri-idler-roll assembly.

The wrap angle around the sensing roller should not change during the installation process.

2 U-Series are mounted in pairs, one at each end of a sensing roller.

3 Both load cells must face the same direction (observe cables as they exit the load cells). The

label on the load cell assures proper alignment with respect to resultant force Fres (load direction).

4 Use caution when selecting and installing the bearing bolts. Bolts that are too long will damage

the load cell. Make sure they are the proper length (see Dimensions).

5 Wire each load cell to the controller or amplifi er using shielded 4 conductor cable. The cable

will require a female 4 pin M12 connector at one end to connect to the male U-Series connector.

6 For additional wiring, calibration and tuning, refer to controller or amplifi er instruction manual.

Fres

bearing

rollerweb

web

Product label indicates allowable range that direction of load (resultant force Fres) must fall within.

Guiding Rollers

Load Cells(note that connectors face same direction)

SensingRoller

Male M12 Load CellConnectors

Female M12 CableConnectors Shielded

4 Conductor Cablesto Conrtroller or Amplifier

Pillow Block Bearing

Pillow Block Bearing

Page 2: U series-installation-instructions-us

EST. 1947

U-Series Under Pillow Block Load CellsInstallation and Operation

1-800-226-8710 / [email protected] / www.montalvo.comTechnical details subject to change without notice. IO-U-series-US-02 © Montalvo

B

C

J

L (max. bolt insertion)

H

E

D

K

A

ØG

ØF

A B C D E ØF ØG H J K L

8.27 2.68 1.10 4.65 1.10 0.27 0.47 0.44 0.50 1/4” 0.63 (134) (44) (28) (118) (28) (7) (12) (11) (12) (M6) (16)

8.27 2.68 1.42 7.09 1.73 0.35 0.59 0.55 0.70 5/16” 0.78 (210) (68) (36) (180) (44) (9) (15) (14) (19) (M8) (20) 11.02 4.09 1.89 9.06 2.60 0.55 0.79 0.83 1.00 1/2” 1.02 (280) (104) (48) (230) (66) (14) (20) (21) (25) (M12) (26) 16.54 5.91 2.60 12.60 3.54 0.87 1.34 1.18 1.30 1/2” 1.34 (420) (150) (66) (320) (90) (22) (34) (30) (34) (M20) (34)

Size

U25

U50

U75

U120

Mounting Bolt Hole (load cell to machine frame) Bolts to be customer supplied.

SHCS - Typ.

Optional Adapter Plate

Mounting Bolt Pattern (bearing to load cell) Montalvo only will drill/tap load cell to customer supplied bearing specifications.

An optional adapter plate may be drilled/tapped by Montalvo or customer.

Note: See dimension L for maximum bolt insrtion length.

Standard Cable includes connector: total length = ~20” (500mm)

Standard Connector - M12 4 Pin Male

Dimensions

Page 3: U series-installation-instructions-us

EST. 1947

U-Series Under Pillow Block Load CellsInstallation and Operation

1-800-226-8710 / [email protected] / www.montalvo.comTechnical details subject to change without notice. IO-U-series-US-02 © Montalvo

Step 1 Determine Weight of Roll, Fg (fig. 1) :

Fg = weight of roll (lb)

Step 2 Determine Resulting Force, Fres (fig. 2) :

Fres = 2.Fweb.sinX/2

Fweb maximum web tension (lb)

X wrap angle of web (º)

lb represents pounds force (TOTAL tension)

Step 3 Determine Height Factor, d (fig. 3) :

d = (a + c) / b

a* perpendicular distance from hinge to mounting surface (in) (see table 1)

b parallel distance from hinge to center of load cell (in) (see table 1)

c center height of selected bearing housing

* add thickness of adapter plate if used ( dimension J )

Step 4 Determine Load Value, Fdim (fig. 4) :

Fdim = ½.Fres.(cosZ + d.sinZ).kdim+½.Fg.(cosY + d.sinY)

Z attacking angle of resulting force (º)

Y attacking angle of Fg

kdim dimensional factor = 1.6

Step 5 Determine Load Rating - lb (N) :

Select nearest rating equal to or greater than larger value Fg or Fdim

Fg answer to Step 1

Fdim answer to Step 4

Rating - Size 25 20 (100) / 50 (250) / 110 (500) / 225 (1000)

Rating - Size 50 110 (500) / 280 (1250) / 560 (2500) / 1120 (5000)

Rating - Size 75 1120 (5000) / 2800 (12500) / 5620 (25000)

Rating - Size 120 5620 (25000) / 11240 (50000) / 22480 (100000)

Fg

Fres

X

ab

c

Z

Y

9 0

180

270

0

Hinge End of load cell must mountso that Resulting Force Fres attacks in:

1st quadrant (0-90º) or3rd quadrant (180-270º)

F res

Gravity

fig. 1 fig. 2

WEB

fig. 3

table 1 in (mm)

fig. 4

ATTACK ANGLES Z & YMeasured counter-clockwise

from center of bearing, starting

at zero (zero perpendicular

to load cell top plate.

a

0.97(24.6)

1.18(30)

1.61(41)

2.17(55)

Size

U25

U50

U75

U120

b

1.5(38)

2.99(76)

3.74(95)

5.24(133)

Calculating Load Cell Size

Mounting AngleHear are a few examples of how the U-Series can be mounted with respect to load direction (resultant force Fres).

Need help calculating load cell size?Download Montalvo’s Pillow Block Load Cell Calculator at http://www.montalvo.com/support/tools/

Page 4: U series-installation-instructions-us

EST. 1947

ElectricalSupply voltage...........................................................................5 VDC

Output...................................................... 250 mV, nominal @ full load

Gauge: Resistance .........................................................80 - 130 Ω

Type .......................................................... semi-conductor

Non-Repeatability .......................................................±0.2% full span

Non-Linearity & hysteresis (combined) ........................±0.5% full span

Connector (standard)

Type ............................................................................Male 4 pin M12

Pin 1.....................................................................................Excitation

Pin 2.......................................................................................... Signal

Pin 3............................................................................. No connection

Pin 4.....................................................................................Excitation

Cable length (including connector) ............................... 20 in. (500mm)

Non-standard cable (optional)............................................. By request

No connector (optional) ...................................................... By request

Load Rating* lb (N)

25 .................................... 20 (100) / 50 (250) / 110 (500) / 225 (1000)

50 .......................... 110 (500) / 280 (1250) / 560 (2500) / 1120 (5000)

75 ................................... 1120 (5000) / 2800 (12500) / 5620 (25000)

120 ......................... 5620 (25000) / 11240 (50000) / 22480 (100000)

Overload Rating lb (N)

25 ......................................................................................675 (3000)

50 .................................................................................3660 (15000)

75 ...............................................................................16860 (75000)

120 ...........................................................................67440 (300000)

Overload stops ................................................... Factory set @ 110%

* Recommended that Montalvo be contacted to ensure proper sizing.

EnvironmentalEnclosure protection class...........................................................IP 67

Operating temp. °F (°C) ..................................-4 to +185 (-20 to +85)

Mechanical in (mm)

Deflection (at nominal force) ............... 0.005 to 0.010 (0.3 to 0.25) typ.

Material ......................................................................... stainless steel

Material Option (for U25 only) ...............................................aluminum

Dimensions in (mm)

25 ................................................. 5.28 x 1.73 x 1.10 (134 x 44 x 28)

50 ................................................ 8.27 x 2.68 x 1.42 (210 x 68 x 36)

75 .............................................. 11.02 x 4.09 x 1.89 (280 x 104 x 48)

120 ........................................... 16.54 x 5.91 x 2.60 (420 x 150 x 66)

Weight lb (kg) approx. (does not include bearing or optional adapter)

25 ..........................................................................................2.5 (1.1)

50 .............................................................................................6 (2.5)

75 ..............................................................................................18 (8)

120 ..........................................................................................60 (26)

BearingsSelf-aligning.................................................................Recommended

207-856-2501 / 800-226-8710+86-21-61401822+45 75 57 27 11

www.montalvo.com/contacts

U-Series Under Pillow Block Load CellsInstallation and Operation

1-800-226-8710 / [email protected] / www.montalvo.comTechnical details subject to change without notice. IO-U-series-US-02 © Montalvo

Specifi cations

Wiring

T - Tension GaugeC - Compression Gauge4

21

3 4

21

2 (white)4 (black)1 (brown or red)

2 (white)4 (black)1 (brown or red)

3 4

21

3 4

21

3

Male 4 pin M12 connector (on load cell) Pin 1.................................... Excitation Pin 2 ......................................... Signal Pin 3.............................No connection Pin 4.................................... Excitation

WEB TENSION APPLIEDTO SENSING ROLLER

(Fres)

RollerBearingLoad Cell

T C

1 4 2

T C

1 4 2

OutputSignal

Excitation5 VDC

Cable ConnectorFemale 4 pin M12x1(view of terminals)

Cable ConnectorFemale 4 pin M12x1(view of terminals)

- +- +

Standard Montalvo 4 conductor cable wiring