This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
3/4"
SUSPENSION (BY
OTHER)
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
T&G GRID CLIPS
* ACOUSTICAL BACKER RECOMMENDED
T&G GRID CLIP FOR
15
16
" HD T-GRID ONLY
6" = 1'-0"
1
TYPICAL AUDITION PLANK SECTION DETAIL
1' = 1'-0"
2
T&G GRID CLIP
1' = 1'-0"
3
T&G DIRECT ATTACH CLIP
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
AUDITION T&G CEILING SYSTEM - SECTION & CLIP OPTIONS
SHEET NUMBER
1
TONGUE SIDE
GROOVE SIDE
PERFORATIONS (DO
NOT GO THROUGH TO
FRONT SIDE OF PANEL)
PLANK FACE
TONGUE SIDE
GROOVE SIDE
PLANK FACE
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
16MM SPACING BETWEEN KERFS SHOWN. 8MM, 24MM, AND 32MM OPTIONS AVAILABLE
SHEET NUMBER
2
START PATTERN
FROM ROOM CENTER
15
16
" H.D. T-BAR GRID
MAINS BY OTHER
(2'-0" O.C. TYP)
℄
JOINTS TO LAND
ON T-GRID
JOINTS TO LAND
ON T-GRID
START PATTERN
FROM ROOM CENTER
15
16
" H.D. T-BAR GRID
MAINS BY OTHER
(2'-0" O.C. TYP)
℄
1/2" = 1'-0"
1
TYPICAL PATTERN RCP (OPTION 1 - CENTERED ON PLANK)
1/2" = 1'-0"
2
TYPICAL PATTERN RCP (OPTION 2 - CENTERED ON REVEAL)
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
AUDITION T&G CEILING SYSTEM - EDGE CONDITIONS @ WALL
SHEET NUMBER
6
8" MAXIMUM
CANTILEVER
SUSPENSION
(BY OTHER)
WALL ANGLE
(BY OTHER)
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
FIELD CUT TO ALLOW
FOR
1
2
" MIN REVEAL
FOR EXPANSION AND
CONTRACTION
T&G GRID CLIP
* ACOUSTICAL BACKER RECOMMENDED
SUSPENSION
(BY OTHER)
WALL ANGLE
(BY OTHER)
FIELD CUT TO ALLOW
FOR
1
2
" MIN REVEAL
FOR EXPANSION AND
CONTRACTION
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
T&G GRID CLIP
3" = 1'-0"
1
WALL ANGLE BELOW - SIDE SECTION
3" = 1'-0"
2
WALL ANGLE BELOW - FRONT SECTION
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
AUDITION T&G CEILING SYSTEM - EDGE CONDITIONS @ WALL
SHEET NUMBER
7
AUDITION PLANK
INDEPENDENTLY SUPPORTED
SPRINKLER: FIELD CUT
PENETRATION
IF PENETRATION EXCEEDS
2
3
BOARD WIDTH, SUPPORT
BRACKETS ARE NEEDED
(BY OTHER)
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
T&G GRID CLIP
INDEPENDENTLY SUPPORTED
SPRINKLER: FIELD CUT
PENETRATION
IF PENETRATION EXCEEDS
2
3
BOARD WIDTH, SUPPORT
BRACKETS ARE NEEDED
(BY OTHER)
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
T&G GRID CLIP
SUPPORT BRACKET
FASTENED W/ SCREWS
TO PLANKS (BY OTHER)
PIPE HANGER ANCHORED
TO BUILDING STRUCTURE
(BY OTHER)
SUSPENSION (BY OTHER)
1 1/2" = 1'-0"
1
SPRINKLER HEAD DETAIL - PLAN VIEW
1 1/2" = 1'-0"
2
SPRINKLER HEAD DETAIL - SECTION VIEW
2
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
AUDITION T&G CEILING SYSTEM - SPRINKLER HEAD DETAIL
SHEET NUMBER
8
AUDITION PLANK
INDEPENDENTLY SUPPORTED
CAN LIGHT: FIELD CUT
PENETRATION
IF PENETRATION EXCEEDS
2
3
BOARD WIDTH, SUPPORT
BRACKETS ARE NEEDED
(BY OTHER)
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
T&G GRID CLIP
INDEPENDENTLY SUPPORTED
CAN LIGHT: FIELD CUT
PENETRATION
TRIM RING (BY OTHER)
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
T&G GRID CLIP
1 1/2" = 1'-0"
1
CAN LIGHT DETAIL - PLAN VIEW
1 1/2" = 1'-0"
2
CAN LIGHT DETAIL - SECTION VIEW
2
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
AUDITION T&G CEILING SYSTEM - PENDANT LIGHT DETAIL
SHEET NUMBER
10
AUDITION PLANK
INDEPENDENTLY SUPPORTED
SPEAKER: FIELD CUT
PENETRATION
IF PENETRATION EXCEEDS
2
3
BOARD WIDTH, SUPPORT
BRACKETS ARE NEEDED
(BY OTHER)
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
T&G GRID CLIP
INDEPENDENTLY SUPPORTED
SPEAKER: FIELD CUT
PENETRATION
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
TRIM PLATE
(BY OTHER)
T&G GRID CLIP
SUSPENSION
(BY OTHER)
1 1/2" = 1'-0"
1
RECESSED SPEAKER DETAIL - PLAN VIEW
1 1/2" = 1'-0"
2
RECESSED SPEAKER DETAIL - SECTION VIEW
2
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
AUDITION T&G CEILING SYSTEM - RECESSED SPEAKER DETAIL
SHEET NUMBER
11
AUDITION PLANK
INDEPENDENTLY SUPPORTED
AUDITION LIGHT: FIELD CUT
PENETRATION
BRACKETS REQ'D
(BY OTHER)
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
T&G GRID CLIP
T&G GRID CLIP
INDEPENDENTLY SUPPORTED
AUDITION LIGHT: FIELD CUT
PENETRATION
15
16
" HEAVY DUTY
T-GRID (BY OTHER)
TRIM PLATE
(BY OTHER)
SUSPENSION
(BY OTHER)
1" = 1'-0"
1
LINEAR LIGHT DETAIL - PLAN VIEW
1 1/2" = 1'-0"
2
LINEAR LIGHT DETAIL - SECTION VIEW
2
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
AUDITION T&G WALL SYSTEM - HORIZONTAL WALL SECTION
SHEET NUMBER
16
16"
O.C. TYP
JOINTS TO LAND ON FRAMING
START PATTERN FROM BASE
BOARD (FIELD RIP TONGUE)
ACOUSTICAL BACKER
RECOMMENDED
BETWEEN FURRING
FURRING (BY OTHER)
24"
O.C. TYP JOINTS TO LAND ON FRAMING
START PATTERN FROM BASE
BOARD (FIELD RIP TONGUE)
ACOUSTICAL BACKER
RECOMMENDED
BETWEEN FURRING
FURRING (BY OTHER)
1/2" = 1'-0"
1
TYPICAL HORIZONTAL STAGGERED WALL PATTERN - 16 INCH SPACING
1/2" = 1'-0"
2
TYPICAL HORIZONTAL STAGGERED WALL PATTERN - 24 INCH SPACING
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
AUDITION T&G WALL SYSTEM - HORIZONTAL WALL PATTERN
SHEET NUMBER
17
ALL JOINTS
CENTERED
ON FURRING
TYP. WALL ASSEMBLY
(BY OTHER)
16 GA. FINISH
NAIL (BY OTHER)
T&G DIRECT
ATTACHMENT
CLIP SCREWED TO
FRAMING IN FIELD
TRIM TO COINCIDE W/
FURRING THICKNESS
FASTENED W/ FINISH
NAIL (OPTIONAL)
FURRING (BY OTHER)
FASTENED TO
STRUCTURE IN FIELD:
ACOUSTICAL BACKER
RECOMMENDED
BETWEEN FURRING
1 1/2" = 1'-0"
1
HORIZONTAL WALL SYSTEM ISOMETRIC
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
AUDITION T&G WALL SYSTEM - HORIZONTAL TRIM CONDITIONS
SHEET NUMBER
19
TYP. WALL SYSTEM
(BY OTHER)
T&G DIRECT ATTACH CLIP
SCREWED TO FRAMING
FURRING (BY OTHER)
FASTENED TO STRUCTURE
IN FIELD: ACOUSTICAL
BACKER RECOMMENDED
BETWEEN FURRING
3" = 1'-0"
1
LINEAR VERTICAL WALL SECTION
1' = 1'-0"
2
DIRECT ATTACHMENT CLIP
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
AUDITION T&G WALL SYSTEM - VERTICAL TRIM CONDITIONS
SHEET NUMBER
23
LIGHT SWITCH PENETRATION FIELD CUT
FURRING (BY OTHER)
FASTENED TO STRUCTURE
IN FIELD: ACOUSTICAL
BACKER RECOMMENDED
BETWEEN FURRING
T&G DIRECT ATTACH CLIP
SCREWED TO FRAMING
TYP. WALL SYSTEM (BY OTHER)
LIGHT SWITCH PENETRATION FIELD CUT
FURRING (BY OTHER)
FASTENED TO STRUCTURE
IN FIELD: ACOUSTICAL
BACKER RECOMMENDED
BETWEEN FURRING
3" = 1'-0"
1
LIGHT SWITCH DETAIL - ELEVATION
3" = 1'-0"
2
LIGHT SWITCH DETAIL - SECTION
2
LAST REVISED: DRAWN BY:SCALE: AS NOTED
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS
DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS