Top Banner
For Reference of NECA 2016 Boston Attendees Only 1 October 10, 2016 Enhance System Models With Real Electrical Components Enhance System Models With Real Electrical Components Judy Miller SysQue This session is eligible for 1 Contact Hour. For these hours to appear on your certificate, you must: Have your badge scanned at the door Attend 90% of this presentation Fill out the online evaluation for this session
9

TW-17_Enhance System Models with Real Electrical ...

Dec 16, 2016

Download

Documents

duonglien
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: TW-17_Enhance System Models with Real Electrical ...

ForReferenceofNECA2016BostonAttendeesOnly 1

October10,2016

Enhance System Models With Real Electrical Components

Enhance System Models With Real Electrical Components

Judy MillerSysQue

This session is eligible for 1 Contact Hour.

For these hours to appear on your certificate, you must:– Have your badge scanned at the door– Attend 90% of this presentation– Fill out the online evaluation for this session

Page 2: TW-17_Enhance System Models with Real Electrical ...

ForReferenceofNECA2016BostonAttendeesOnly 2

October10,2016

Design to Construction Revit MEP

• Real Content - Example: Electrical

Design to Construction Revit MEP

• Real Content - Example: Electrical

Page 3: TW-17_Enhance System Models with Real Electrical ...

ForReferenceofNECA2016BostonAttendeesOnly 3

October10,2016

Design to Construction Revit MEP

• Real Content - Example: Electrical

Design to Construction Revit MEP

• Real Content - Example: Electrical

Page 4: TW-17_Enhance System Models with Real Electrical ...

ForReferenceofNECA2016BostonAttendeesOnly 4

October10,2016

Design to Construction Revit MEP

Design to Construction Revit MEP

• Real Content - Example: Electrical

Page 5: TW-17_Enhance System Models with Real Electrical ...

ForReferenceofNECA2016BostonAttendeesOnly 5

October10,2016

SysQue Electrical• SysQue Electrical adds LOD

300-400 real world content to electrical BIM coordination with 3D Revit families

• Revit families based on manufacturers’ bent conduit tube, basket, cable tray, busway and rack.

• Manufacturers, such as B-Line and Allied, provide Revit BIM with accurate PDF specifications sheets, including dimensions and installation methods.

Design to Construction Revit MEP

• Real Content - Example: Electrical

Page 6: TW-17_Enhance System Models with Real Electrical ...

ForReferenceofNECA2016BostonAttendeesOnly 6

October10,2016

Converting Generic Conduit• Select the SysQue system to convert

the conduit to (material, panel/circuit, or wirefill)

• If you want to specify the Service Type and color, edit the straight length of conduit icon by right clicking and select edit

• Select all like sizes of generic conduit to be converted

• If you don’t want cut lengths and couplings to be placed during the conversion, click on “Process Fittings”

• Select “Change System”

Converting Generic Conduit• Select the SysQue system to

convert the conduit to (material, panel/circuit, or wirefill)

• If you want to specify the Service Type and color, edit the straight length of conduit icon by right clicking and select edit

• Select all like sizes of generic conduit to be converted

• If you don’t want cut lengths and couplings to be placed during the conversion, click on “Process Fittings”

• Select “Change System”

Page 7: TW-17_Enhance System Models with Real Electrical ...

ForReferenceofNECA2016BostonAttendeesOnly 7

October10,2016

Converting Generic Cable Tray• Select the SysQue system to

convert the cable tray to• If you don’t want cut lengths

and couplings to be placed during the conversion, click on “Process Fittings”

Converting Generic Conduit• If you want to specify the

Service Type and color, edit the straight length of cable tray icon by right clicking and select edit

• Select all like heights of generic tray to be converted

• Select “Change System”

Page 8: TW-17_Enhance System Models with Real Electrical ...

ForReferenceofNECA2016BostonAttendeesOnly 8

October10,2016

Common Steps for Converting Content

Select “Change System”

Step3

Select generic content

Step2

Select SysQue System

Step1

Supports for ElectricalSysQueSupportsautomaticallypopulatesyourPipes,Ducts,CableTrays,Conduitsaccordingtothehangerparts,hardware,andspecsyoudefine,andletsyoucreatedetailedhangermapsandprefabdrawings.

Page 9: TW-17_Enhance System Models with Real Electrical ...

ForReferenceofNECA2016BostonAttendeesOnly 9

October10,2016

Questions? For more Information:Visit us in Booth 1511