C-TRS9-00 PRODUCT TECHNICAL DATA The Roofing Store P: HEAD OFFICE 09 277 2717 ALBANY 09 972 0060 KATIKAIT 07 549 5190 WELLINGTON 04 974 5792 CHRISTCHURCH 03 348 6528 WEB: www.theroofingstore.co.nz Copyright ゥ The Roofing Store 2013 1:5 SCALE: DETAIL NUMBER: TITLE: TRS 9 DESCRIPTION TRS 9 profile is designed for commercial and industrial roofing. The profile is suitable for low pitch roofing as well as curved roofing. Commercial and industrial roofing G550 grade steel with minimum 0.55 BMT gives more resilience to damage. SPECIFICATION AT A GLANCE GENERAL Minimum Roof Pitch 3 Degree Effective Cover 910mm Max. Unsupported Overhang Contact "The Roofing Store" SPANS End Span 0.55 BMT 2300mm Internal Span 0.55 BMT 3200mm DRAPE CURVE 0.55mm BMT G300 Min. 90m Radius WALL CLADDING FIXINGS Cladding fixing on 20mm, 12 Gauge class 4 screws with neo washers, miss 2 pans, miss 3pans, every H 3.1 treated batterns second on ends ROOF FIXINGS Low / Medium wind Zone Timber: class 4 14 x 75mm with neo washer and embossed washer Steeltite: 12 x 65mm with neo washer and embossed washer High wind Zone Timber: class 4 14 x 75mm with neo washer and embossed washer, approved profile's metal washer and EPDM washer Steeltite: 12 x 65mm with neo washer and embossed washer, approved profile's metal washer and EPDM washer Very High Wind Zone Contact "The Roofing Store" Specific Design Wind Zone Contact "The Roofing Store" ROOF FIXING LENGTHS Dark Colour Up To 8 Meters Solid fix Light Colour Up To 12 Meters Solid fix sheet lengths Excess Above* Oversize holes required for movement *Contact The Roofing Store for further information on specific design FIXINGS, FASTENING AND UNDERLAY All fixings and fasteners are to be of an approved type, compatible with all materials, the environment and meeting the requirements of the NZ Building Code. Installation is to be in accordance with the NZ Metal Roof and Wall Cladding Code of Practice or manufacturer's instructions. Fix every crest to: Ridge, Hip, Valley, Gutter and Periphery area. Underlay as per the project specification is to be used. COATINGS AND COMPLIANCE WITH AS/NZS 2728 (CORROSION RESISTANCE) The KiwiColour brand is available in two different product lines designed specifically to suit different environmental and atmospheric conditions; KiwiColour VITOR & KiwiColour ZENEX. Independent laboratory tests have confirmed that KiwiColour VITOR complies with the corrosion resistance performance requirements of AS/NZA 2728 with regards to Product Type 4 (the corrosivity category into which most populated areas of New Zealand fall) in all aspects of salt spray performance and humidity resistance and including other product properties such as coating thickness, gloss and cross hatch adhesion(Gloss category 2 ). Independent testing demonstrated that Kiwicolour ZENEX samples met the corrosion resistance performance requirements of AS/NZS 2728:2007 for Product Types 3 and 4. Refer to Product literature for selection of suitable finishing and warranty. All kiwi colour materials are available on Master spec . 35MM 78MM 150MM 78MM 38MM THICKNESS END SPAN INTERNAL SPAN MINIMUM PITCH 0.55MM 2.30M 3.20M 3ー NTS
12
Embed
TRS 9 - Rooftech · roof pitch "e 10° very high wind zone. roof pitch < 10° 2 crests 2 crests y extra high wind zone. 2 crests 50mm 70mm z 90mm screw fixing with 12x25 type 17 tek
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
DESCRIPTIONTRS 9 profile is designed for commercial and industrial roofing. The profile is suitable for low pitch roofing as well as curvedroofing. Commercial and industrial roofing G550 grade steel with minimum 0.55 BMT gives more resilience to damage.
SPECIFICATION AT A GLANCEGENERAL Minimum Roof Pitch 3 Degree
Effective Cover 910mmMax. Unsupported Overhang Contact "The Roofing Store"
SPANS End Span 0.55 BMT 2300mmInternal Span 0.55 BMT 3200mm
DRAPE CURVE 0.55mm BMT G300 Min. 90m RadiusWALL CLADDING FIXINGS Cladding fixing on 20mm, 12 Gauge class 4 screws with neo washers, miss 2 pans, miss 3pans, every H 3.1 treated batterns
second on endsROOF FIXINGS Low / Medium wind Zone Timber: class 4 14 x 75mm with neo washer and embossed washer
Steeltite: 12 x 65mm with neo washer and embossed washerHigh wind Zone Timber: class 4 14 x 75mm with neo washer and embossed washer, approved
profile's metal washer and EPDM washerSteeltite: 12 x 65mm with neo washer and embossed washer, approvedprofile's metal washer and EPDM washer
Very High Wind Zone Contact "The Roofing Store"Specific Design Wind Zone Contact "The Roofing Store"
ROOF FIXING LENGTHS Dark Colour Up To 8 Meters Solid fixLight Colour Up To 12 Meters Solid fixsheet lengths Excess Above* Oversize holes required for movement
*Contact The Roofing Store for further information on specific designFIXINGS, FASTENING AND UNDERLAYAll fixings and fasteners are to be of an approved type, compatible with all materials, the environment and meeting the requirements of the NZ Building Code. Installation is to be inaccordance with the NZ Metal Roof and Wall Cladding Code of Practice or manufacturer's instructions. Fix every crest to: Ridge, Hip, Valley, Gutter and Periphery area. Underlay asper the project specification is to be used.COATINGS AND COMPLIANCE WITH AS/NZS 2728 (CORROSION RESISTANCE)The KiwiColour brand is available in two different product lines designed specifically to suit different environmental and atmospheric conditions; KiwiColour VITOR & KiwiColour ZENEX.Independent laboratory tests have confirmed that KiwiColour VITOR complies with the corrosion resistance performance requirements of AS/NZA 2728 with regards to Product Type 4(the corrosivity category into which most populated areas of New Zealand fall) in all aspects of salt spray performance and humidity resistance and including other product propertiessuch as coating thickness, gloss and cross hatch adhesion(Gloss category 2 ). Independent testing demonstrated that Kiwicolour ZENEX samples met the corrosion resistanceperformance requirements of AS/NZS 2728:2007 for Product Types 3 and 4. Refer to Product literature for selection of suitable finishing and warranty. All kiwi colour materials are availableon Master spec .
35MM 78MM 150MM 78MM
38MM
THICKNESS END SPAN INTERNAL SPAN MINIMUM PITCH0.55MM 2.30M 3.20M 3°
FLASHING FIXED DIAGONALLY TOROOFING PROFILE TIO MINIMISEHOLDING OF DIACHARGE WATER
MALLEABLE FLANGE, SCREW OR RIVETFIXED, AND SEALED TO ROOFING PROFILE.FIT NEOPRENE WASHERS TO ALL SCREWFIXINGS
TRS PROFILED METAL ROOFING
PIPE
EPDM FLEXIBLE CONE SLEEVE
Fall
NOTE:(1) MAX. ROOF PITCH FOR THIS FLASHING 45°, MINIMUMPITCH 10° IF BASE OF FLANGE COVERS OVE OR MORECOMPLETE TROUGHS.(2) FOR PIPES UP TO 85mm DIAMETER(3) NZMRM CODE OF PRACTICE ALLOWS LARGER THAN85mm DIAMETER PENETRATION PROVIDED THE FLASHINGDOES NOT EXTEND TO MORE THAN 50% OF PAN WIDTH(4) INSTALL ADJACENT TO PURLIN FOR SUPPORT WHEREPOSSIBLE. NO PANS TO BE FULLY BLOCKED OFF BY PIPE ORDEKTITE