1"=4' 1/4" A1.1 FLOORPLAN SCALE: I HEREBY CERTIFY THAT I HAVE REVIEWED THE ATTACHED DESIGN, AND HAVE FOUND IT TO BE IN COMPLIANCE WITH THE CODES LISTED ON PAGE N1 CUSTOMER: THE ENGINEER HAS NOT REVIEWED THE PRE-ENGINEERED TRUSS MANUFACTURER'S LAYOUT TO DETERMINE ANY LOAD BEARING CONDITIONS AND RESERVES THE RIGHT TO MAKE ANY CHANGES AFTER LOAD INFORMATION IS SUPPLIED TO THE ENGINEER. REVIEWED FOR STRUCTURE ONLY TRINITY DRAFTING LLC 813.482.2463 www.trinitydrafting.com Jody Willis...owner 713 Whitehall St. Plant City, Fl. 33563 ENGINEERS SEAL DRAW DATE: NOTE...PLAN MUST BE PERMITTED WITHIN 6 MONTHS OF DRAW DATE OR REVISION FEES MAY APPLY DATE: 03.26.19 ALL DIMENSIONS SHOWN MAY VARY SLIGHTLY DUE TO MATERIAL SIZES AND THICKNESS. STEPS THAT ARE SHOWN MAY VARY IN NUMBER OF STEPS REQUIRED. STEP SIZE: TREAD 11" MIN-RISER 7-3/4" MAX. ADDRESS: COUNTRY SARASOTA MODEL 3068 2880 HB HB HB AC 2/8 2/8 2/6 1/6 2/0 2/0 2/6 2/6 2/8 2/8 2/4 2/0 2/4 3068 2880 HB HB HB AC 2/8 2/8 2/6 1/6 2/0 2/0 2/6 2/6 2/8 2/8 2/4 2/0 2/4 WINDOW SIZES ALL SIZES ARE APPROXIMATE. REFER TO MANUFACTURER SIZE CHART FOR ACCURATE DIMENSIONS (1H5)...27"W X 63"H (24)...38"W X 50"H *(25)...38"W X 63"H * MEETS EGRESS REQUIREMENT (3014)...36"W X 16"H DOOR SIZE EXAMPLE: (3068)...36"W X 80"H (3080)...36"W X 96"H (XXXX)...WIDTH (FT) AND HEIGHT(FT) *(26)...38"W X 72"H SAMPLE ONLY NOT FOR CONSTRUCTION
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
1"=
4'
1/4
"
A1.1
FLO
OR
PLA
N
SC
ALE
:
I H
ER
EB
Y C
ER
TIF
Y T
HA
T I H
AV
E R
EV
IE
WE
D T
HE
A
TT
AC
HE
D D
ES
IG
N, A
ND
H
AV
E F
OU
ND
IT
T
O B
E IN
C
OM
PLIA
NC
E W
IT
H T
HE
C
OD
ES
LIS
TE
D O
N P
AG
E N
1
CU
ST
OM
ER
:
TH
E E
NG
IN
EE
R H
AS
N
OT
R
EV
IE
WE
D T
HE
P
RE
-E
NG
IN
EE
RE
D T
RU
SS
M
AN
UF
AC
TU
RE
R'S
LA
YO
UT
T
O D
ET
ER
MIN
E A
NY
LO
AD
B
EA
RIN
G
CO
ND
IT
IO
NS
A
ND
R
ES
ER
VE
S T
HE
R
IG
HT
T
O M
AK
E A
NY
C
HA
NG
ES
A
FT
ER
LO
AD
IN
FO
RM
AT
IO
N IS
S
UP
PLIE
D T
O T
HE
E
NG
IN
EE
R.
RE
VIE
WE
D F
OR
S
TR
UC
TU
RE
O
NLY
TRINITY DRAFTING LLC813.482.2463www.trinitydrafting.comJody Willis...owner713 Whitehall St.Plant City, Fl.33563
EN
GIN
EE
RS
S
EA
L
DRAW DATE:
NOTE...PLAN MUST BE
PERMITTED WITHIN 6
MONTHS OF DRAW DATE
OR REVISION FEES MAY
APPLY
DATE: 03.26.19
ALL DIMENSIONS SHOWN MAY VARY SLIGHTLY
DUE TO MATERIAL SIZES AND THICKNESS.
STEPS THAT ARE SHOWN MAY VARY IN NUMBER
OF STEPS REQUIRED.
STEP SIZE: TREAD 11" MIN-RISER 7-3/4" MAX.
AD
DR
ES
S:
CO
UN
TR
Y
SA
RA
SO
TA
MO
DE
L
3068
2880
HB
HB
HB
AC
2/8
2/8
2/6
1/6
2/0
2/0
2/6
2/6
2/8
2/8
2
/
4
2/0
2/4
3068
2880
HB
HB
HB
AC
2/8
2/8
2/6
1/6
2/0
2/0
2/6
2/6
2/8
2/8
2
/
4
2/0
2/4
WINDOW SIZES
ALL SIZES ARE APPROXIMATE.
REFER TO MANUFACTURER SIZE
CHART FOR ACCURATE
DIMENSIONS
(1H5)...27"W X 63"H
(24)...38"W X 50"H
*(25)...38"W X 63"H
* MEETS EGRESS
REQUIREMENT
(3014)...36"W X 16"H
DOOR SIZE EXAMPLE:
(3068)...36"W X 80"H
(3080)...36"W X 96"H
(XXXX)...WIDTH (FT) AND HEIGHT(FT)
*(26)...38"W X 72"H
SAMPLE ONLY
NOT FOR
CONSTRUCTION
A2.1
ELE
VA
TIO
NS
1"=
4'
1/4
"
SC
ALE
:
I H
ER
EB
Y C
ER
TIF
Y T
HA
T I H
AV
E R
EV
IE
WE
D T
HE
A
TT
AC
HE
D D
ES
IG
N, A
ND
H
AV
E F
OU
ND
IT
T
O B
E IN
C
OM
PL
IA
NC
E W
IT
H T
HE
C
OD
ES
L
IS
TE
D O
N P
AG
E N
1
CU
ST
OM
ER
:
TH
E E
NG
IN
EE
R H
AS
N
OT
R
EV
IE
WE
D T
HE
P
RE
-E
NG
IN
EE
RE
D T
RU
SS
M
AN
UF
AC
TU
RE
R'S
LA
YO
UT
T
O D
ET
ER
MIN
E A
NY
LO
AD
B
EA
RIN
G
CO
ND
IT
IO
NS
A
ND
R
ES
ER
VE
S T
HE
R
IG
HT
T
O M
AK
E A
NY
C
HA
NG
ES
A
FT
ER
LO
AD
IN
FO
RM
AT
IO
N IS
S
UP
PLIE
D T
O T
HE
E
NG
IN
EE
R.
RE
VIE
WE
D F
OR
S
TR
UC
TU
RE
O
NLY
TRINITY DRAFTING LLC813.482.2463www.trinitydrafting.comJody Willis...owner713 Whitehall St.Plant City, Fl.33563
EN
GIN
EE
RS
S
EA
L
DRAW DATE:
NOTE...PLAN MUST BE
PERMITTED WITHIN 6
MONTHS OF DRAW DATE
OR REVISION FEES MAY
APPLY
DATE: 03.26.19
ALL DIMENSIONS SHOWN MAY VARY SLIGHTLY
DUE TO MATERIAL SIZES AND THICKNESS.
STEPS THAT ARE SHOWN MAY VARY IN NUMBER
OF STEPS REQUIRED.
STEP SIZE: TREAD 11" MIN-RISER 7-3/4" MAX.
AD
DR
ES
S:
CO
UN
TR
Y
SA
RA
SO
TA
MO
DE
L
AC
AC
AC
DIMENSIONAL ROOF
SHINGLE
STUCCO BANDING
NOTE:
USE 1/4" SCALE FOR VENEER
SIZING AND LOCATION
SAND FINISHED STUCCO
SAMPLE ONLY
NOT FOR
CONSTRUCTION
E7.1
ELE
CT
RIC
AL
1"=
4'
1/4
"
SC
ALE
:
I H
ER
EB
Y C
ER
TIF
Y T
HA
T I H
AV
E R
EV
IE
WE
D T
HE
A
TT
AC
HE
D D
ES
IG
N, A
ND
H
AV
E F
OU
ND
IT
T
O B
E IN
C
OM
PL
IA
NC
E W
IT
H T
HE
C
OD
ES
L
IS
TE
D O
N P
AG
E N
1
CU
ST
OM
ER
:
TH
E E
NG
IN
EE
R H
AS
N
OT
R
EV
IE
WE
D T
HE
P
RE
-E
NG
IN
EE
RE
D T
RU
SS
M
AN
UF
AC
TU
RE
R'S
L
AY
OU
T T
O D
ET
ER
MIN
E A
NY
L
OA
D B
EA
RIN
G
CO
ND
IT
IO
NS
A
ND
R
ES
ER
VE
S T
HE
R
IG
HT
T
O M
AK
E A
NY
C
HA
NG
ES
A
FT
ER
L
OA
D IN
FO
RM
AT
IO
N IS
S
UP
PL
IE
D T
O T
HE
E
NG
IN
EE
R.
RE
VIE
WE
D F
OR
S
TR
UC
TU
RE
O
NLY
TRINITY DRAFTING LLC813.482.2463www.trinitydrafting.comJody Willis...owner713 Whitehall St.Plant City, Fl.33563
EN
GIN
EE
RS
S
EA
L
DRAW DATE:
NOTE...PLAN MUST BE
PERMITTED WITHIN 6
MONTHS OF DRAW DATE
OR REVISION FEES MAY
APPLY
DATE: 03.26.19
ALL DIMENSIONS SHOWN MAY VARY SLIGHTLY
DUE TO MATERIAL SIZES AND THICKNESS.
STEPS THAT ARE SHOWN MAY VARY IN NUMBER
OF STEPS REQUIRED.
STEP SIZE: TREAD 11" MIN-RISER 7-3/4" MAX.
AD
DR
ES
S:
CO
UN
TR
Y
SA
RA
SO
TA
MO
DE
L
3068
2880
HB
HB
HB
AC
2/8
2/8
2/6
1/6
2/0
2/0
2/6
2/6
2/8
2/8
2
/
4
2/0
2/4
BE
LL
P
P
P
P
TV
TV
TV
TV
TV
cc
c c
c
c
c
c
c
c c
SD
SD
SD
SS
SS
S
S
S
SSS
SS
SS
S
SSSSS
SS
SS
SS
SS
S
c
SS
S
S
SWITCHES TO BE ARC FAULT (AFCI) TYPE
ALL (NON GFI) 110V RECEPTICLES AND
TO BE GFI.
AREAS (TUBS, SHOWERS, SINKS,ETC..)
ALL RECEPTACLES WITHIN 6' OF WET
ELECTRICAL NOTES:
DISCREPANCY
OWNER/BUILDER TO VERIFY LOCATION OF
CODE SUPERSEDES PLANS IN CASE OF
ALL ELECTRICAL TO MEET ELECTRICAL (NEC)
AND FIRE CODES
INSTALLATION
ELECTRICAL PANEL/METER LOCATION
TO BE DETERMINED
ALL ELECTRICAL DEVICES BEFORE
ALL 110V RECEPTICLES MUST BE TAMPER
RESISTANT
VERIFY WITH OWNER FOR LOW
VOLTAGE (PHONE,TV, ETC) LOCATIONS
ALL RECEPTACLES ON THE EXTERIOR OF
THE HOME TO BE WEATHER RESISTANT
(COVERED) GFI
NOTE: FL STATE STATUTE 471.003(2)
ELECTRICAL, PLUMBING, AND MECHANICAL CONTRACTORS
MAY PROVIDE ALL NECESSARY INFORMATION NEEDED FOR
PERMITTING FOR A PROJECT OF THIS SIZE WITHOUT AN
ENGINEERS SEAL.
NOTE:
IT IS THE RESPONSIBILITY OF THE SUB CONTRACTOR TO
REVIEW THE PLANS FOR ACCURACY. THE SUB
CONTRACTOR HAS THE RIGHT AND RESPONSIBILITY TO
CHANGE OR CORRECT THE PLANS IN ORDER TO MEET THE
REQUIREMENTS THEIR COMPANY DEEMS NECESSARY TO
FULFILL THEIR WARRANTY. PLANS MUST ALSO MEET THE
PRESENT CODE REQUIREMENTS.
FAN/LIGHT
BATH
DETECTOR
BELL DOOR BELL
FAN
CEILING
TV
PHONE JACK
P
CAN LIGHT
LIGHT
110V RECEPTACLE
SWITCH
SMOKE SD
CEILING FAN-LIGHT
2' FLUORESCENT
RECEPTACLE
220V
BATH FAN
FLOOD-LIGHT
TV JACK WITH
RECEPTACLE
S
SWITCH(THREE WAY)S
SWITCH (FOUR WAY)S
3
4
110V RECEPTACLE
4
QUAD
4' FLUORESCENT
LEGEND
UNDER
CABINET
LIGHT
SS
S
SAMPLE ONLY
NOT FOR
CONSTRUCTION
NO
TE
S-D
ES
IG
N
LO
AD
S A
ND
PR
OD
UC
T
AP
PR
OV
AL
N1
I H
ER
EB
Y C
ER
TIF
Y T
HA
T I H
AV
E R
EV
IE
WE
D T
HE
A
TT
AC
HE
D D
ES
IG
N, A
ND
H
AV
E F
OU
ND
IT
T
O B
E IN
C
OM
PLIA
NC
E W
IT
H T
HE
C
OD
ES
LIS
TE
D O
N P
AG
E N
1
CU
ST
OM
ER
:
TH
E E
NG
IN
EE
R H
AS
N
OT
R
EV
IE
WE
D T
HE
P
RE
-E
NG
IN
EE
RE
D T
RU
SS
M
AN
UF
AC
TU
RE
R'S
LA
YO
UT
T
O D
ET
ER
MIN
E A
NY
LO
AD
B
EA
RIN
G
CO
ND
IT
IO
NS
A
ND
R
ES
ER
VE
S T
HE
R
IG
HT
T
O M
AK
E A
NY
C
HA
NG
ES
A
FT
ER
LO
AD
IN
FO
RM
AT
IO
N IS
S
UP
PLIE
D T
O T
HE
E
NG
IN
EE
R.
RE
VIE
WE
D F
OR
S
TR
UC
TU
RE
O
NLY
TRINITY DRAFTING LLC813.482.2463www.trinitydrafting.comJody Willis...owner713 Whitehall St.Plant City, Fl.33563
EN
GIN
EE
RS
S
EA
L
DRAW DATE:
NOTE...PLAN MUST BE
PERMITTED WITHIN 6
MONTHS OF DRAW DATE
OR REVISION FEES MAY
APPLY
DATE: 03.26.19
ALL DIMENSIONS SHOWN MAY VARY SLIGHTLY
DUE TO MATERIAL SIZES AND THICKNESS.
STEPS THAT ARE SHOWN MAY VARY IN NUMBER
OF STEPS REQUIRED.
STEP SIZE: TREAD 11" MIN-RISER 7-3/4" MAX.
AD
DR
ES
S:
CO
UN
TR
Y
SA
RA
SO
TA
MO
DE
L
…
SAMPLE ONLY
NOT FOR
CONSTRUCTION
PM4.1
PL
UM
BIN
G
AN
D A
C
1"=
4'
1/4
"
SC
AL
E:
I H
ER
EB
Y C
ER
TIF
Y T
HA
T I H
AV
E R
EV
IE
WE
D T
HE
A
TT
AC
HE
D D
ES
IG
N, A
ND
H
AV
E F
OU
ND
IT
T
O B
E IN
C
OM
PLIA
NC
E W
IT
H T
HE
C
OD
ES
LIS
TE
D O
N P
AG
E N
1
CU
ST
OM
ER
:
TH
E E
NG
IN
EE
R H
AS
N
OT
R
EV
IE
WE
D T
HE
P
RE
-E
NG
IN
EE
RE
D T
RU
SS
M
AN
UF
AC
TU
RE
R'S
LA
YO
UT
T
O D
ET
ER
MIN
E A
NY
LO
AD
B
EA
RIN
G
CO
ND
IT
IO
NS
A
ND
R
ES
ER
VE
S T
HE
R
IG
HT
T
O M
AK
E A
NY
C
HA
NG
ES
A
FT
ER
LO
AD
IN
FO
RM
AT
IO
N IS
S
UP
PLIE
D T
O T
HE
E
NG
IN
EE
R.
RE
VIE
WE
D F
OR
S
TR
UC
TU
RE
O
NLY
TRINITY DRAFTING LLC813.482.2463www.trinitydrafting.comJody Willis...owner713 Whitehall St.Plant City, Fl.33563
EN
GIN
EE
RS
S
EA
L
DRAW DATE:
NOTE...PLAN MUST BE
PERMITTED WITHIN 6
MONTHS OF DRAW DATE
OR REVISION FEES MAY
APPLY
DATE: 03.26.19
ALL DIMENSIONS SHOWN MAY VARY SLIGHTLY
DUE TO MATERIAL SIZES AND THICKNESS.
STEPS THAT ARE SHOWN MAY VARY IN NUMBER
OF STEPS REQUIRED.
STEP SIZE: TREAD 11" MIN-RISER 7-3/4" MAX.
AD
DR
ES
S:
CO
UN
TR
Y
SA
RA
SO
TA
MO
DE
L
3068
2880
HB
HB
HB
AC
2/8
2/8
2/6
1/6
2/0
2/0
2/6
2/6
2/8
2/8
2
/
4
2/0
2/4
PLUMBING LAYOUT TO BE SUPPLIED BY
MECHANICAL PLAN/ENGINEERING AND ENERGY
CALCS TO BE SUPPLIED BY A/C COMPANY
PLUMBING COMPANY
NOTES:
Location of shutoff valves.
Shutoff valves shall be installed in the following locations:
1. On the fixture supply to each plumbing fixture other than bathtubs and showers in one- and two-family
residential occupancies, and other than in individual sleeping units that are provided with unit shutoff valves in
hotels, motels, boarding houses and similar occupancies.
2. On the water supply pipe to each sillcock in other than one- and two-family residential occupancies.
3. On the water supply pipe to each appliance or mechanical equipment.
REQUIRED:
HOT WATER TEMPERING VALVES
AT HW FIXTURES(NOT TO EXCEED
110 DEGREES FAHRENHEIT)
Horizontal drains within buildings.
All horizontal drains shall be provided with cleanouts located not more than 100 feet apart.
Building sewers.
Building sewers shall be provided with cleanouts located not more than 100 feet apart measured from the upstream
entrance of the cleanout. For building sewers 12 inches and larger, manholes shall be provided and located not more
than 200 feet (60 960 mm) from the junction of the building drain and building sewer, at each change in direction and at
intervals of not more than 400 feet (122 m) apart. Manholes and manhole covers shall be of an approved type.
(1)
(2)
(3)
(4)
(5)
1...AC CONDENSER UNIT
2...AC (CONCRETE SLAB) POURED OR PREFAB
3...2" *BMP AC TIE DOWN ANCHOR LOCATED AT EACH CORNER) TOTAL OF (4)
4...3/16"X1" SHEET METAL SCREWS. (2) PER ANCHOR.
5...1/4"X2-1/2" TAPCON. (1) PER ANCHOR
* FLORIDA PRODUCT APPROVAL #FL14239.1
AC CONDENSER UNIT ANCHOR DETAIL
NOTE: FL STATE STATUTE 471.003(2)
ELECTRICAL, PLUMBING, AND MECHANICAL CONTRACTORS
MAY PROVIDE ALL NECESSARY INFORMATION NEEDED FOR
PERMITTING FOR A PROJECT OF THIS SIZE WITHOUT AN
ENGINEERS SEAL.
NOTE:
IT IS THE RESPONSIBILITY OF THE SUB CONTRACTOR TO
REVIEW THE PLANS FOR ACCURACY. THE SUB
CONTRACTOR HAS THE RIGHT AND RESPONSIBILITY TO
CHANGE OR CORRECT THE PLANS IN ORDER TO MEET THE
REQUIREMENTS THEIR COMPANY DEEMS NECESSARY TO
FULFILL THEIR WARRANTY. PLANS MUST ALSO MEET THE
PRESENT CODE REQUIREMENTS.
FIXTURE SCHEDULE:
LAVS...(STANDARD) WITH STANDARD LEVER FAUCET
SINKS...(STANDARD) WITH STANDARD LEVER FAUCET
TOILETS...(STANDARD) TANK TYPE (PORCELAIN)
TUBS... (STANDARD) FIBERGLASS, ACRYLIC, OR PORCELAIN VENEER
(1)...TOILET
(2)...SINK
(3)...LAVATORIE
(4)...SHOWER
(5)...TUB
(6)...DISHWASHER
(7)...WASH MACHINE
TO SEPTIC
OR SEWER
GRADE
TWO WAY
CLEAN OUT
3"
2" 3" 3" 3" 3"
3"2"
3"
3"2"
VENTS
2"
ROOF
BOOTS
2"2"2"
(1)
3"
(4)
2"
(3)(3)
2"
2"
(1)
3"
(5)
2"
(3)
2"
STUDOR
VENT
2"
(2)(2)
(6)
2"
2"
2"
(7)
2"
(1)...TOILET
(2)...SINK
(3)...LAVATORIE
(4)...SHOWER
(5)...TUB
(6)...DISHWASHER
(7)...WASH MACHINE
TO SEPTIC
OR SEWER
GRADE
TWO WAY
CLEAN OUT
3"
3"3"3"3"3"
2"
3" 3"
2"
3"
VENTS
2"
ROOF
BOOTS
2"2"2"
(1)
3"
(4)
2"
(3)(3)
2"
2"
(1)
3"
(5)
2"
(3)
2"
STUDOR
VENT
2"
(2)(2)
(6)
2"
2"
2"
(7)
2"
3"
SAMPLE ONLY
NOT FOR
CONSTRUCTION
S3.1
ST
RU
CT
UR
AL
DE
TA
ILS
I H
ER
EB
Y C
ER
TIF
Y T
HA
T I H
AV
E R
EV
IE
WE
D T
HE
A
TT
AC
HE
D D
ES
IG
N, A
ND
H
AV
E F
OU
ND
IT
T
O B
E IN
C
OM
PL
IA
NC
E W
IT
H T
HE
C
OD
ES
L
IS
TE
D O
N P
AG
E N
1
CU
ST
OM
ER
:
TH
E E
NG
IN
EE
R H
AS
N
OT
R
EV
IE
WE
D T
HE
P
RE
-E
NG
IN
EE
RE
D T
RU
SS
M
AN
UF
AC
TU
RE
R'S
LA
YO
UT
T
O D
ET
ER
MIN
E A
NY
LO
AD
B
EA
RIN
G
CO
ND
IT
IO
NS
A
ND
R
ES
ER
VE
S T
HE
R
IG
HT
T
O M
AK
E A
NY
C
HA
NG
ES
A
FT
ER
LO
AD
IN
FO
RM
AT
IO
N IS
S
UP
PLIE
D T
O T
HE
E
NG
IN
EE
R.
RE
VIE
WE
D F
OR
S
TR
UC
TU
RE
O
NLY
TRINITY DRAFTING LLC813.482.2463www.trinitydrafting.comJody Willis...owner713 Whitehall St.Plant City, Fl.33563
EN
GIN
EE
RS
S
EA
L
DRAW DATE:
NOTE...PLAN MUST BE
PERMITTED WITHIN 6
MONTHS OF DRAW DATE
OR REVISION FEES MAY
APPLY
DATE: 03.26.19
ALL DIMENSIONS SHOWN MAY VARY SLIGHTLY
DUE TO MATERIAL SIZES AND THICKNESS.
STEPS THAT ARE SHOWN MAY VARY IN NUMBER
OF STEPS REQUIRED.
STEP SIZE: TREAD 11" MIN-RISER 7-3/4" MAX.
AD
DR
ES
S:
CO
UN
TR
Y
SA
RA
SO
TA
MO
DE
L
GABLE TRUSS
7/8" STUCCO OVER LATHE OVER FELT
OVER HOUSEWRAP OVER 7/16" OSB OR
PLYWOOD SHEETING.
COMMON TRUSSES
2X4 CONTINUOS TOP RAIL BRACE.
2X4 CONTINUOUS
BOTTOM RAIL BRACE
(LAID FLAT ON BOTTOM
CHORD OF TRUSS)
2X6 "X" BRACING (APPROX. 45 DEGREES). NAIL
INTO TOP AND BOTTOM RAIL BRACES WITH (3)
16D COMMON NAILS (EACH CONNECTION)
2X6 VERTICAL BRACE AGAINST
GABLE TRUSS. NAIL INTO TOP AND
BOTTOM RAIL BRACES (OR "X"
BRACES) WITH (3) 16D COMMON
NAILS (EACH CONNECTION)
"X" BRACING MUST EXTEND AT
LEAST 10' FROM GABLE
TRUSS...MULTIPLE "X" BRACING
CAN BE USED TO ACHIEVE THE
10' DISTANCE
BLOCK WALL
PERMANENT GABLE BRACING
EMBEDDED META 20 STRAP EVERY
48"OC. BEND OVER GABLE TRUSS
BOTTOM CHORD AND TAPCON TO
BLOCK WALL WITH 3/16"X 1-3/4"
TAPCONS...UNLESS STRAP LAYS
BEHIND TRUSS WEB BRACE (THEN
ATTACH FLAT TO WEB BRACE)
2X4 BOTTOM RAIL BRACE (ON EDGE)
WEEP SCREED
PORCH BEAM AND
POST DETAIL
SEE FOUNDATION PAGE
NON BEARING FRAME
WALL TO BLOCK WALL
ATTACHMENT
BLOCK
WALL
NAIL TO BLOCK WALL
EVERY 16"OC WITH #10
CASEHARD NAILS OR
GUN NAIL
PT BACKER FURRING NOT SHOWN
NOTE: INSTALL MIDPOINT BLOCKING ON
WALLS TALLER THAN 10'
NON BEARING DOOR
FRAME AND WALL
PT SHOE
PLATE
USE 16D
COMMON NAILS
(4) PER STUD
2X TOP PLATE
DOOR JACK
STUD
2X BLOCKING 16"OC
(1) 2X
LAYING FLAT
2X
STUDS
16"OC
SECURE TO SLAB
WITH #8 CASE HARD
NAILS EVERY 16"OC
COVER BOTH SIDES
WITH 1/2"
SHEETROCK/DRYWALL
SINGLE BOND BEAM (KNOCK OUT LINTEL
BLOCK) POURED SOLID WITH 3000 PSI CONC.
WITH (1) #5 HORIZONTAL REBAR (25" MIN
LAP)...SEE PAGE S6.2 FOR AMOUNT OF REBAR
REQUIRED OVER OPENINGS
TO FOOTER
8X16 CMU BLOCK (STAGGER
STACKED) WITH 1/2" MORTAR (ASTM
C270) JOINTS
POURED CELL (3000 PSI CONC.) WITH
(1) #5 REBAR FROM FOOTER TO
LINTEL (10" MIN BEND INTO BOTH.) W/
25" LAP (MIN.)
SLAB
WIRE MESH
BARRIER UNDER
KNOCK OUT
TYPICAL CMU BLOCK WALL DETAIL
SINGLE BOND BEAM (KNOCK
OUT LINTEL BLOCK) POURED
SOLID WITH 3000 PSI CONC.
WITH (1) #5 REBAR (25" MIN
LAP)...UNLESS MARKED
TO FOOTER
8X16 CMU BLOCK (STAGGER
STACKED) WITH 1/2" MORTAR (ASTM
C270) JOINTS
POURED CELL (3000 PSI CONC.) WITH
(1) #5 REBAR FROM FOOTER TO
LINTEL (10" MIN BEND INTO BOTH.) W/
25" LAP (MIN.)
SLAB
WIRE MESH
BARRIER UNDER
KNOCK OUT
TYPICAL DOOR AND WINDOW
OPENING IN CMU BLOCK WALL
DOOR
WINDOW
PRECAST
WINDOW SILL
NOTE: DOUBLE BOND BEAM
LINTEL IN WALLS OVER 10'
UP TO 14' IN HT.
WALL FURRING REQUIREMENTS: (TYPICAL)
(1)...VERTICAL 1X2 PT FURRING EVERY 16"OC MAX.
(2)...VERTICAL 1X4 PT FURRING EACH SIDE OF WINDOW AND DOOR OPENINGS.