TrilliumSeries™ Condenser TABLE OF CONTENTS 1 TRILLIUMSERIES™ FLUID COOLER 2 BENEFITS 4 MODES OF OPERATION 5 ENGINEERING DATA 6 ECOFLEX CONTROLS TrilliumSeries™ Fluid Cooler BAC AUSTRALIA
TrilliumSeries™ CondenserT A B L E O F C O N T E N T S
1 TRILLIUMSERIES™FLUIDCOOLER
2 BENEFITS
4 MODESOFOPERATION
5 ENGINEERINGDATA
6 ECOFLEXCONTROLS
TrilliumSeries™ Fluid Cooler
B A C A U S T R A L I A
1 Q U E S T I O N S ? C A L L 1 3 0 0 . 1 3 4 . 6 2 2 O R V I S I T W W W . B A L T I M O R E A I R C O I L . C O M . A U
TheTrilliumSeries™FluidCooler
›› TheTrilliumSeries™FluidCooler›` BOOSTS THERMAL PERFORMANCE
• Upto40%improvedcapacitycomparedtodrycooling
• TrilliumSeries™coolersconsumelessenergyandachievelowerprocesstemperatures
›` REDUCES WATER CONSUMPTION
• Waterisusedonlywhentheambienttemperaturerequiresit(Upto70%savings)
• Waterfromtheunitcanbeusedforirrigation
• Watermonitoringpackageminimizeswateruse
›` NEEDS MINIMAL MAINTENANCE
• Takessametimeasaircooled
• Nowatertreatmentrequired
• On-DemandAdiabatic™Pre-CoolerMediacanbereplacedin½hour
›` TOP HYGIENE CONTROL
• MinimisingtheriskofLegionella
• Nochemicalwatertreatmentrequired
• Removingtheissuesofcompliancy(RMPsandregularaudits)
The TrilliumSeries™ Fluid Cooler features a Dry-Coil Adiabatic™ Design coupled with proprietary logic and customised Ecoflex controls. These features save water and prevent the need for any water treatment by minimising the risk of Legionella. In addition they also boost thermal performance compared to standard dry-coil products. Because of this the TrilliumSeries™ Fluid Cooler is ideal for small to medium HVAC and industrial applications or where limited water or space is available.
M A R 4 1 2 - 0 2
Benefits
›› OwnershipBenefitsIn a variety of climate conditions, the TrilliumSeries™ Fluid Cooler provides the lowest total cost of ownership compared to air cooled units.›` INSTALLATION ADVANTAGES
• Compactandlighterinweightcomparedtostandardaircooled
• Singlepointelectricalconnection
• DirectdriveVSECmotorsandWhisperQuietFansarestandard
• Nowatertreatmentrequired
›` ECONOMIC ADVANTAGES
• Booststhermalperformanceupto40%comparedtostandardaircooled
• Upto70%watersavingscomparedtoevaporativeequipment.
• Savingsduetonowatertreatment.
›› OptionalBuilt-inEnergyTracking/Alarms›` Optionalalarmsforthefans,pumpsandvalves
›` Optionalenergymonitoringmaintainsefficientoperationoverthelifeoftheproduct
›› On-DemandAdiabatic™Pre-Cooler›` WaterisusedONLYwhentheambienttemperaturerequiresit
• WaterspraysaturatesandcleanstheOn-DemandAdiabatic™Pre-Coolermediaofanydustanddebris
›` Nowatertreatmentisrequired
›` Freedrainingpreventsstagnantwater
• Waterfromthedrainandoverflowcanbeusedforirrigationorothernon-potableuses
›` CONTROLS OPTIONS
• WATER QUALITY SENSOR(OPTION) -Flushesthesumpbasedonafactorypresetconductivityleveltominimizewateruse.
• WATER MONITORING (OPTION) -Thisoptionmonitorstheamountofpurgedwaterandmaintainsefficientoperationoverthelifeoftheproduct.
›› LowSound›` WhisperQuietFansarestandard
›` DirectdriveVSECfanmotorsvarythefanspeedeliminatingsuddenstartsandstops
Average Annual Water Use Comparedto Evaporative Fluid Coolers
Bleed
Evaporation
Evaporative Fluid Cooler
TrilliumSeries™ Fluid Cooler
70% Savings
Unit
Type
Normal Conversation 60AquaVenta Operating at Full Speed 70Traffic on a busy road 80Air Cooled Condenser 84Jack Hammer 100
100
90
80
70
60
100
90
80
Noise L
evel
(dB)
70
60
Noise Level (dB)
Sound Levels
3 Q U E S T I O N S ? C A L L 1 3 0 0 . 1 3 4 . 6 2 2 O R V I S I T W W W . B A L T I M O R E A I R C O I L . C O M . A U
Benefits
›› EasyMaintenance›`Requiresthesametimetomaintainasaircooled
fluidcooler
›`Watertreatmentisnotrequired
•Wateristurnedononlywhenambienttemperaturerequiresit
•WaterspraysaturatesandcleanstheOn-DemandAdiabatic™Pre-Coolermediaofanydustanddebris
›`On-DemandAdiabatic™Pre-Coolermediaactsasafiltertopreventdebrisfromreachingthecoil
•Canberemovedwithouttoolsforeasycoilinspection
›`TheEcoFlexControlsmaintainacleansump
›`Pumpandstrainerareeasilyaccessiblefromtheaccesshatch
›› PeaceofMind›` AllunitsareequippedwithstateoftheartEcoFlexcontrols,On-DemandAdiabatic™Pre-Cooler,and
dailyautomaticsumpcleanout
›` Criticalcomponentsarestockedandshipwithin24-hours
›` Durablematerialsofconstructionextendthelifeoftheunit
›` Sumpanddrainpansdrainfreely
›` Abilitytoswitchfansfromautomatictomanualfanoverrideincaseofcontrolsignalloss
M A R 4 1 2 - 0 4
ModesofOperation
›› DryModeWhentheambientairisbelowthesetpoint,theunitrunsasadrycoolertosavewaterandenergy.Theambientaircoolsthefluidinthecoilswhichisthenreturnedtothesystem.
›› On-DemandAdiabatic™Pre-CoolerModeWhentheunitisinOn-DemandAdiabatic™Pre-Coolermode,waterisevenlysprayedoverthehighlyefficientmedia.Theairishumidifiedasitpassesthroughthemedia,coolingtemperaturesdownto1-2ºCabovewet-bulbtemperature.Suchsubstantialdepressionofthedrybulbtemperatureresultsinamajorincreaseindrycoolingcapacity.
Thecoolerairpassesoverthecoilandcoolsthefluidinsidewhichisthenreturnedtothesystem.Inthesumpthereisanindustrialdutypumpthatrecirculatesthewater.Partofthedistributedwaterisevaporated,whiletheexcesswaterassistsinrinsingtheOn-DemandAdiabatic™Pre-Coolermedia.TheEcoFlexControlsdeterminewhenthewaterispurgedfromthesump.
›` ON-DEMAND ADIABATIC™ PRE-COOLER OPERATION MODES Therearethreedifferentwaystooptimizeunitoperation.
• Standard Logic (Default):ThecontrollerwillstartthePre-CoolerModeatapresetoutsideairtemperaturetoincreasetheunit’scapacityandefficiency.
• Water Saver Logic:Thecontrollerwilloptimizetheunit’sdryefficiencyandonlyusewaterwhentheconditionsrequiretheextracoolingcapacity.Pre-CoolerModewillbeinitiatedonlywhentheoutsideairtemperatureisabovetheswitchpointandthefansarerunningat90%oraboveforover60seconds.Thismodewillrecheckconditionseverytwohours.
• Energy Saver Logic: Thecontrollerwilloptimizeitssequencesothattheleastamountofenergyisconsumedtomeetthepresentloadoftheunit.Pre-CoolerModewillbeinitiatedat5.5degreesbelowtheswitchpointandifthefanspeedisabove35%.
Dry Mode
Wet Mode
5 Q U E S T I O N S ? C A L L 1 3 0 0 . 1 3 4 . 6 2 2 O R V I S I T W W W . B A L T I M O R E A I R C O I L . C O M . A U
ModelCapacity
(kW)[1] MotorkW PumpkWAirflow(m3/s)
UnitLength(L)
Width(W)
Height(H)
ShippingWeight
(kg)
OperatingWeight
(kg)
TVFC-384 172 3 x 3.1 0.18 18.1 4000 1167 2545 1400 1900
TVFC-684 345 6 x 3.1 0.18 36.3 4000 2334 2545 2000 2500
TVFC-882 442 8 x 3.1 0.36 47.8 4900 2500 2750 2857 3486
TVFC-884 467 8 x 3.1 0.36 47.8 4900 2500 2750 2857 3486
TVFC-1082 561 10 x 3.1 0.36 59.7 5800 2500 2750 3075 3900
TVFC-1084 584 10 x 3.1 0.36 59.7 5800 2500 2750 3075 3900
TVFC-1282 679 12 x 3.1 0.36 71.7 6700 2500 2750 4286 5229
TVFC-1284 702 12 x 3.1 0.36 71.7 6700 2500 2750 4286 5229
TVFC-1482 796 14 x 3.1 0.36 83.6 7600 2500 2750 5250 6350
TVFC-1484 819 14 x 3.1 0.36 83.6 7600 2500 2750 5250 6350
NOTES:
1. Capacity is based on cooling water from 35˚C to 29˚C with dry bulb of 35˚C and wet bulb of 21˚C.
Do not use for construction. Refer to factory certified dimensions. This catalogue includes
data current at the time of publication, which should be reconfirmed at the time of purchase.
Up-to-date information can be found at www.BaltimoreAircoil.com.au
EngineeringData
M A R 4 1 2 - 0 6
EcoFlexControls
The TrilliumSeries™ Fluid Cooler is furnished standard with state of the art EcoFlex Controls that provide efficient year round performance. Each unit is shipped with custom controls logic that reduces energy consumption and optimizes water usage. The system is pre-programmed and ready to operate upon arrival from the factory.
›› EcoFlexControlsLogicFeatures›` ENERGY MONITORING–MeasurestheenergyuseoftheTrilliumSeries™FluidCoolerandverifiesefficientoperationoverthe
lifeoftheequipment.
›` WATER MONITORING –Measuresthewateruseandmaintainsefficientoperationoftheunit.
›` ALARMS –Signalsprovidedforfans,pumps,orvalves.
›` COMMUNICATIONS CARDS–AllowsforseamlessintegrationoverModbusandBACnettomonitorallsystemcomponentsinasinglelocation.
AmbientTemperature ≥
Set Point
On-Demand Adiabatic™ Pre-Cooler Mode
ON
Vary Fan Speed Basedon Fan Signal
Start Pump Sequence
On-Demand Adiabatic™ Pre-Cooler Mode
OFF
Vary Fan Speed Basedon Fan Signal
ContinueMonitoringAmbient
Temp
ControlsLogic
7 Q U E S T I O N S ? C A L L 1 3 0 0 . 1 3 4 . 6 2 2 O R V I S I T W W W . B A L T I M O R E A I R C O I L . C O M . A U
COOLING TOWERS
CLOSED CIRCUIT COOLING TOWERS
ICE THERMAL STORAGE
EVAPORATIVE CONDENSERS
HYBRIDPRODUCTS
PARTS & SERVICES
w w w . B a l t i m o r e A i r c o i l . c o m . a u
120 Wisemans Ferry Road, Somersby NSW 2250 › Telephone (Australia): 1300.134.622 › Telephone (New Zealand): 0800.225.842