101 Room name 101 1 A101 SIM DOOR TAG ROOM TAG SECTION www.gregerseninteriors.com Scale Date Drawn By Checked By Project Number 1/4" = 1'-0" 5/20/2011 9:30:27 AM A0.0 Cover Sheet Trillium Hospital Administration Building Checker Author Issue Date 12 TRILLIUM HOSPITAL ADMINISTRATION BUILDING 1518 DIVISADERO AVE SAN FRANCISCO, CA 95114 No. Description Date GENERAL NOTES: 1. PRIOR TO COMMENCING THE WORK, THE CONTRACTOR SHALL EXAMINE ALL CONTRACT DOCUMENTS, FIELD CONDITIONS, DIMENSIONS, ETC. FOR ACCURACY AND TO CONFIRM THAT THE WORK IS BUILDABLE AS SHOWN. THE CONTRACTOR SHALL PROMPTLY INFORM THE ARCHITECT, IN WRITING, OF ANY DISCREPANCIES AND SHALL OBTAIN CLARIFICATION FROM THE ARCHITECT PRIOR TO PROCEEDING WITH THE WORK IN QUESTION OR WITH ANY RELATED WORK. 2. THE CONTRACTOR SHALL VERIFY AND COORDINATE WALLS AND FRAMING THAT REQUIRE A NON-TYPICAL THICKNESS DUE TO STRUCTURAL, ELECTRICAL, MECHANICAL, EQUIPMENT, OR OTHER REQUIREMENTS. 3. ALL STUD WALLS AND PARTITION FRAMING SHALL MEET STRUCTURAL REQUIREMENTS OF THE LATEST EDITION OF THE UBC AND THE CALIFORNIA ADMENDMENTS. 5. VERIFY MOUNTING HEIGHTS OF BACKING PLATES AND SPECIAL STRUCTURAL SUPPORT REQUIREMENTS WITH EQUIPMENT MANUFACTURERS BEFORE INSTALLING BACKING PLATES AND SUPPORT. 6. ALL THROUGH-PENETRATION FIRE STOPS SHALL COMPLY WITH UBC SECTION 714. 7. WHEN INSTALLING DRILLED-IN ANCHORS AND/OR POWDER-DRIVEN PINS IN NON- PRESTRESSED REINFORCED CONCRETE, USE CARE AND CAUTION TO AVOID CUTTING OR DAMAGING THE EXISTING REINFORCING BARS. 8. ALL DOORS AND PENETRATIONS IN WALLS AND PARTITIONS SHALL MAINTAIN THE REQUIRED FIRE PROTECTION RATING OF THAT WALL OR PARTITION. WHERE A CONFLICT BETWEEN PARTITION RATING AND DOOR/FRAME RATING OCCURS NOTIFY ARCHITECT PRIOR TO PROCEEDING. 9. ALL INTERIOR FINISHES IN ONE-HOUR RATED AREAS SHALL BE CONSTRUCTED WITH CLASS 2 MATERIALS. ALL OTHER MATERIALS SHALL BE CLASS 3 FIRE-RESISTANT MATERIALS, PER THE LATEST CODES AND STATUTES. 10. TYPICAL DOOR LEG IS 4" OFF WALL ADJACENT PERPENDICULAR WALL OR PARTITION. 11. ALL DOOR HARDWARE SHALL COMPLY WITH THE CURRENT REQUIREMENTS AND GUIDELINES FOR ACCESS BY THE PHYSICALLY DISABLED (TITLE-24). 12. PROVIDE WEATHER STRIPPING FOR DOORS SEPARATING CONDITIONED AND UNCONDITIONED SPACES PER TITLE 24. 13. ALL EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A SPECIAL KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT, EXCEPTION PER UBC. PROVIDE READILY VISIBLE DURABLE SIGN ON OR ADJACENT TO THE DOOR, STATING "THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS." LETTERS SHALL BE 1" HIGH ON A CONTRASTING BACKGROUND. 14. PROVIDE EXIT SIGNS PER UBC AND CALIFORNIA ADMENDMENTS 15. A FLOOR PLAN PROVIDING EMERGENCY PROCEDURAL INFORMATION SHALL BE POSTED AT EVERY STAIRWAY AND ELEVATOR LANDING, AND IMMEDIATELY INSIDE ALL PUBLIC ENTRANCES TO THE BUILDING. INFORMATION SHALL INCLUDE BUT NOT LIMITED TO THE FOLLOWING: A. LOCATION OF EXITS AND FIRE ALARM INITIATING STATIONS. B. DESCRIPTION OF FIRE ALARM HORN AND STROBE. C. FIRE DEPARTMENT EMERGENCY TELEPHONE NUMBER 9-1-1. D. THE PROHIBITION OF THE USE OF ELEVATORS DURING EMERGENCIES. E. INSTRUCTIONS TO BE FOLLOWED BY AMBULATORY, NON-AMBULATORY, AND PHYSICALLY DISABLED PERSONS IN THE EVENT OF AN EMERGENCY. SIGN SHALL BE PRINTED WITH A MIN. OF 3/16 INCH HIGH NON-DECORATIVE LETTERING PROVIDING A SHARP CONTRAST TO THE BACKGROUND. THE INFORMATION SHALL INCLUDE THE FLOOR LEVEL AND BE POSTED SO THAT THE BOTTOM EDGE OF SUCH SIGNAGE IS LOCATED NOT MORE THAN 4' ABOVE THE FLOOR. (TITLE 19, CCR, SECTION 3.09). 16. FIRE EXTINGUISHERS ARE TO BE LOCATED AS REQUIRED BY THE GOVERNING REGULATORY AGENCIES. 17. FIRE SPRINKLERS SHALL COMPLY WITH UBC CHAPTER 9 AND UBC STD 9-1. FIRE SPRINKLER PLANS SHALL BE SUBMITTED FOR REVIEW TO THE PROPER REVIEWING AGENCY PRIOR TO CONSTRUCTION. CONCEALED SPACES SHOULD BE SPRINKLERED. 18. A COMPLEMENT OF FIRE EXTINGUISHERS WITH A MIN. CLASSIFICATION OF 2A10BC SHALL BE MOUNTED SO THAT THE MAX. TRAVEL DISTANCE TO AN EXTINGUISHER, ON A FLOOR BY FLOOR BASIS, IS 75 FEET. IN ACCORDANCE WITH THE UFC STANDARD, THE TOP OF THE FIRE EXTINGUISHERS SHALL BE MOUNTED NO HIGHER THAN FIVE FEET FROM THE FLOOR. EXTINGUISHERS WHICH ARE NOT READILY VISIBLE FROM ALL DIRECTIONS SHALL BE PROVIDED WITH SIGNAGE TO INDICATE THEIR LOCATION. (UFC 1002) 19. APPROVED STAIRWAY IDENTIFICATION SIGNS SHALL BE LOCATED AT EACH FLOOR LEVEL WITHIN ALL ENCLOSED STAIRWELLS. THE SIGN SHALL IDENTIFY THE STAIRWAY, INDICATE WHETHER THERE IS ROOF ACCESS, THE FLOOR LEVEL, AND THE LOWER AND UPPER TERMINUS OF THE STAIRWAY. THE SIGN SHALL BE PLACED APPROXIMATELY 5' ABOVE THE FLOOR LANDING IN A POSITION WHICH IS READILY VISIBLE WHEN THE DOOR IS IN THE OPEN OR CLOSED POSITION. SEE APPENDIX C OF THE UNIFORM FIRE CODE. (UFC SECTION 1210.4) 20. AS MUCH AS PRACTICAL, RE-USE ITEMS FROM ELSEWHERE IN THE BUILDING. VERIFY WITH OWNER WHICH ITEMS WILL BE RE-USED. 21. CONTRACTOR TO MAINTAIN CODE COMPLYING EXITING AND SPRINKLERS DURING CONSTRUCTION. 22. THE AUTOMATIC FIRE SPRINKLER SYSTEM IS REQUIRED TO BE MODIFIED IN THIS BUILDING. THE DESIGNER/INSTALLER SHALL SUBMIT PERMIT DRAWINGS, COMPLYING WITH THE REQUIREMENTS OF NFPA 13, INCLUDING HYDRAULIC CALCULATIONS, EARTHQUAKE BRACING AND HANGER FASTENER CALCULATIONS, TO THE DISTRICT FOR REVIEW AND PERMIT. (CFC 1001.3/1003) 23. COMPLIANCE WITH CFC ARTICLE 87 "FIRESAFETY DURING CONSTRUCTION, ALTERATION OR DEMOLITION OF A BUILDING" IS MANDATORY. 24. (E) BUILDING ENVELOPE COMPLIES WITH TITLE24 UNDER PREVIOUS SUBMITTAL. PROPOSED CHANGES DO NOT DECREASE ENVELOPE PERFORMANCE. SYMBOL LEGEND: PROJECT DATA: PROJECT TEAM: SCOPE OF WORK: DEFERRED SUBMITTALS: VICINITY MAP: BUILDING CODES: 2001 CALIFORNIA BUILDING CODE BASED ON THE 1997 EDITION OF THE UBC 2001 CALIFORNIA PLUMBING CODE, BASED ON 2000 UPC 2001 CALIFORNIA MECHANICAL CODE, BASED ON 2000 UMC 2004 CALIFORNIA ELECTRIC CODE BASED ON 2002 NEC 2005 BUILDING ENERGY EFFICIENCY STANDARDS 2001 CALIFORNIA FIRE CODE LEGAL JURISDICTION: CITY OF SAN JOSE, CA SAN JOSE FIRE DISTRICT, CA APN: 678-16-8 PLANNING ZONE: IP-B CONSTRUCTION TYPE: V-N BUILDING OCCUPANCY: B, F-1, S-2 FIRE PROTECTION: BUILDING IS PROVIDED WITH AUTOMATIC FIRE SPRINKLER SYSTEM THROUGHOUT SITE AREA: 29.88 ACRES BUILDING AREA: 125,000 SF AREA OF IMPROVEMENT: 125,000 SF PARKING PROVIDED: SEE SHEET G0.04 FOR PARKING ANALYSIS DEFERRED SUBMITTAL ITEMS SHALL BE REVIEWED AND APPROVED BY THE ARCHITECT OR THE ENGINEER OF RECORD PRIOR TO SUBMITTAL FOR THE BUILDING OFFICIAL FOR APPROVAL. DEFERRAL OF ANY ITEM SHALL HAVE APPROVAL OF THE BUILDING OFFICIAL OF THEIR DESIGN AND SUBMITTAL DOCUMENTS PRIOR TO ANY INSTALLATION. 1/ FIRE SPRINKLER SYSTEM 2/ HIGH LEVEL STOCK RACK 3/ BURN-IN CHAMBER SEISMIC ATTACHMENT 4/ TOOLS INSTALLATIONS ARE TO BE UNDER SEPARATE PERMIT. NEW WORK: TENANT IMPROVEMENT OF OFFICE, STORAGE, AND MANUFACTURING AREA. NEW TRASH ENCLOSURE, AND NEW EXTERIOR DOORS WILL BE INSTALLED. DEMOLITION: 1. INTERIOR NON-STRUCTURAL PARTITIONS, FINISHES, FIXTURES, EQUIPMENT AS INDICATED ARE TO BE REMOVED. PROJECT LOCATION CLIENT : JDFHALEFHLAEU LAIEHLAIWUEHFLWE 1901 SDF;S ROAD SAN FRANCISCO, CA. PHONE: (415) 165-7234 FAX: (415) 165-7210 CONTACT: DJFA ALKJSHFLAW STRUCTURAL ENGINEER: IRELAND ENGINEERING 43551 MISSION BLVD., STE. 110 FREMONT, CA. 94539 PHONE: 510.438.9632 FAX: 510.438.0689 CONTACT: ASDF ASDFHAJS FACILITIES DEVELOPMENT: SIGMATECH FACILITIES DEVELOPMENT 3333 BOWERS AVE., STE. 130 SANTA CLARA, CA 95050 PHONE: (408) 988-4345 FAX: (408) 748-1826 CONTACT: ASDF IOUF WU MECHANICAL ENGINEER: SILICON VALLEY MECHANICAL 980 N. 11TH ST. SAN JOSE, CA. 95112 PHONE: 408.885.0500 FAX: 408.885.0505 CONTACT: ERAE ADFHALWF ARCHITECT: ACADEMY OF ART UNITVERSITY 2900 STOCKTON STREET SAN FRANCISCO, CA. 94102 PHONE: 415.681.6453 FAX: 415.68.2632 CONTACT: UOIU NAO;NFN ELECTRICAL ENGINEER: MIDSTATE ELECTRIC, INC. 1855 KIRKMONT DR. SAN JOSE, CA. 95124 PHONE: 408.374.9077 FAX: 408.266.0565 CONTACT: ASD ALSDFA GENERAL CONTRACTOR: DEVCON CONSTRUCTION, INC. 690 GILBRALTAR DR. MILPITAS, CA 95035 PHONE: (408) 942-8200 FAX: (408) 262-2342 CONTACT: MARK JOHNSON PLUMBING ENGINEER: METRO PLUMBING 834 LENZEN AVE. SAN JOSE, CA. 95126 PHONE: 408.287.7551 FAX: 408.287.0831 CONTACT: SDFASD ALSDFKS SHEET INDEX: Sheet Number Sheet Name A0.0 Cover Sheet A1.0 Demolition Plans A2.1 Floor Plan Level 1 A2.2 Floor Plan Level 2 A3.1 Ceiling Plan Level 1 A3.2 Ceiling Plan Level 2 A4.0 Exterior Elevations and Building Sections A5.1 Interior Elevations - 1 A5.2 Interior Elevations - 2 A6.1 Finishes Plan Level 1 A6.2 Finishes Plan Level 2 A7.1 Furniture Plan Level 1 A7.2 Furniture Plan Level 2 A8.0 Door and Room/ Finishes Schedules A9.0 Interior Details
15
Embed
TRILLIUM HOSPITAL ADMINISTRATION BUILDING...CONTACT: SDFASD ALSDFKS SHEET INDEX: Sheet Number Sheet Name A0.0 Cover Sheet A1.0 Demolition Plans A2.1 Floor Plan Level 1 A2.2 Floor Plan
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
101
Room name101
1A101
SIM
DOOR TAG
ROOM TAG
SECTION
www.gregerseninteriors.com
Scale
Date
Drawn By
Checked By
Project Number
1/4" = 1'-0"
5/20
/201
1 9:
30:2
7 AM
A0.0
Cover Sheet
Trillium Hospital
AdministrationBuilding
CheckerAuthor
Issue Date12
TRILLIUM HOSPITALADMINISTRATION BUILDING
1518 DIVISADERO AVESAN FRANCISCO, CA 95114
No. Description Date
GENERAL NOTES:1. PRIOR TO COMMENCING THE WORK, THE CONTRACTOR SHALL EXAMINE ALL CONTRACTDOCUMENTS, FIELD CONDITIONS, DIMENSIONS, ETC. FOR ACCURACY AND TO CONFIRMTHAT THE WORK IS BUILDABLE AS SHOWN. THE CONTRACTOR SHALL PROMPTLY INFORMTHE ARCHITECT, IN WRITING, OF ANY DISCREPANCIES AND SHALL OBTAIN CLARIFICATIONFROM THE ARCHITECT PRIOR TO PROCEEDING WITH THE WORK IN QUESTION OR WITH ANYRELATED WORK.
2. THE CONTRACTOR SHALL VERIFY AND COORDINATE WALLS AND FRAMING THATREQUIRE A NON-TYPICAL THICKNESS DUE TO STRUCTURAL, ELECTRICAL, MECHANICAL,EQUIPMENT, OR OTHER REQUIREMENTS.
3. ALL STUD WALLS AND PARTITION FRAMING SHALL MEET STRUCTURAL REQUIREMENTS OFTHE LATEST EDITION OF THE UBC AND THE CALIFORNIA ADMENDMENTS.
5. VERIFY MOUNTING HEIGHTS OF BACKING PLATES AND SPECIAL STRUCTURAL SUPPORTREQUIREMENTS WITH EQUIPMENT MANUFACTURERS BEFORE INSTALLING BACKINGPLATES AND SUPPORT.
6. ALL THROUGH-PENETRATION FIRE STOPS SHALL COMPLY WITH UBC SECTION 714.
7. WHEN INSTALLING DRILLED-IN ANCHORS AND/OR POWDER-DRIVEN PINS IN NON-PRESTRESSED REINFORCED CONCRETE, USE CARE AND CAUTION TO AVOID CUTTING ORDAMAGING THE EXISTING REINFORCING BARS.
8. ALL DOORS AND PENETRATIONS IN WALLS AND PARTITIONS SHALL MAINTAIN THEREQUIRED FIRE PROTECTION RATING OF THAT WALL OR PARTITION. WHERE A CONFLICTBETWEEN PARTITION RATING AND DOOR/FRAME RATING OCCURS NOTIFY ARCHITECTPRIOR TO PROCEEDING.
9. ALL INTERIOR FINISHES IN ONE-HOUR RATED AREAS SHALL BE CONSTRUCTED WITHCLASS 2 MATERIALS. ALL OTHER MATERIALS SHALL BE CLASS 3 FIRE-RESISTANTMATERIALS, PER THE LATEST CODES AND STATUTES.
10. TYPICAL DOOR LEG IS 4" OFF WALL ADJACENT PERPENDICULAR WALL OR PARTITION.
11. ALL DOOR HARDWARE SHALL COMPLY WITH THE CURRENT REQUIREMENTS ANDGUIDELINES FOR ACCESS BY THE PHYSICALLY DISABLED (TITLE-24).
12. PROVIDE WEATHER STRIPPING FOR DOORS SEPARATING CONDITIONED ANDUNCONDITIONED SPACES PER TITLE 24.
13. ALL EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF ASPECIAL KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT, EXCEPTION PER UBC.PROVIDE READILY VISIBLE DURABLE SIGN ON OR ADJACENT TO THE DOOR, STATING "THISDOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS." LETTERS SHALL BE 1" HIGH ONA CONTRASTING BACKGROUND.
14. PROVIDE EXIT SIGNS PER UBC AND CALIFORNIA ADMENDMENTS
15. A FLOOR PLAN PROVIDING EMERGENCY PROCEDURAL INFORMATION SHALL BEPOSTED AT EVERY STAIRWAY AND ELEVATOR LANDING, AND IMMEDIATELY INSIDE ALLPUBLIC ENTRANCES TO THE BUILDING. INFORMATION SHALL INCLUDE BUT NOT LIMITED TOTHE FOLLOWING:
A. LOCATION OF EXITS AND FIRE ALARM INITIATING STATIONS.B. DESCRIPTION OF FIRE ALARM HORN AND STROBE.C. FIRE DEPARTMENT EMERGENCY TELEPHONE NUMBER 9-1-1.D. THE PROHIBITION OF THE USE OF ELEVATORS DURING EMERGENCIES.E. INSTRUCTIONS TO BE FOLLOWED BY AMBULATORY, NON-AMBULATORY, ANDPHYSICALLY DISABLED PERSONS IN THE EVENT OF AN EMERGENCY.
SIGN SHALL BE PRINTED WITH A MIN. OF 3/16 INCH HIGH NON-DECORATIVE LETTERINGPROVIDING A SHARP CONTRAST TO THE BACKGROUND. THE INFORMATION SHALLINCLUDE THE FLOOR LEVEL AND BE POSTED SO THAT THE BOTTOM EDGE OF SUCHSIGNAGE IS LOCATED NOT MORE THAN 4' ABOVE THE FLOOR. (TITLE 19, CCR, SECTION 3.09).
16. FIRE EXTINGUISHERS ARE TO BE LOCATED AS REQUIRED BY THE GOVERNINGREGULATORY AGENCIES.
17. FIRE SPRINKLERS SHALL COMPLY WITH UBC CHAPTER 9 AND UBC STD 9-1. FIRESPRINKLER PLANS SHALL BE SUBMITTED FOR REVIEW TO THE PROPER REVIEWINGAGENCY PRIOR TO CONSTRUCTION. CONCEALED SPACES SHOULD BE SPRINKLERED.
18. A COMPLEMENT OF FIRE EXTINGUISHERS WITH A MIN. CLASSIFICATION OF 2A10BC SHALLBE MOUNTED SO THAT THE MAX. TRAVEL DISTANCE TO AN EXTINGUISHER, ON A FLOOR BYFLOOR BASIS, IS 75 FEET. IN ACCORDANCE WITH THE UFC STANDARD, THE TOP OF THE FIREEXTINGUISHERS SHALL BE MOUNTED NO HIGHER THAN FIVE FEET FROM THE FLOOR.EXTINGUISHERS WHICH ARE NOT READILY VISIBLE FROM ALL DIRECTIONS SHALL BEPROVIDED WITH SIGNAGE TO INDICATE THEIR LOCATION. (UFC 1002)
19. APPROVED STAIRWAY IDENTIFICATION SIGNS SHALL BE LOCATED AT EACH FLOORLEVEL WITHIN ALL ENCLOSED STAIRWELLS. THE SIGN SHALL IDENTIFY THE STAIRWAY,INDICATE WHETHER THERE IS ROOF ACCESS, THE FLOOR LEVEL, AND THE LOWER ANDUPPER TERMINUS OF THE STAIRWAY. THE SIGN SHALL BE PLACED APPROXIMATELY 5'ABOVE THE FLOOR LANDING IN A POSITION WHICH IS READILY VISIBLE WHEN THE DOORIS IN THE OPEN OR CLOSED POSITION. SEE APPENDIX C OF THE UNIFORM FIRE CODE.(UFC SECTION 1210.4)
20. AS MUCH AS PRACTICAL, RE-USE ITEMS FROM ELSEWHERE IN THE BUILDING. VERIFYWITH OWNER WHICH ITEMS WILL BE RE-USED.
21. CONTRACTOR TO MAINTAIN CODE COMPLYING EXITING AND SPRINKLERS DURINGCONSTRUCTION.
22. THE AUTOMATIC FIRE SPRINKLER SYSTEM IS REQUIRED TO BE MODIFIED IN THISBUILDING. THE DESIGNER/INSTALLER SHALL SUBMIT PERMIT DRAWINGS, COMPLYING WITHTHE REQUIREMENTS OF NFPA 13, INCLUDING HYDRAULIC CALCULATIONS, EARTHQUAKEBRACING AND HANGER FASTENER CALCULATIONS, TO THE DISTRICT FOR REVIEW ANDPERMIT. (CFC 1001.3/1003)
23. COMPLIANCE WITH CFC ARTICLE 87 "FIRESAFETY DURING CONSTRUCTION, ALTERATIONOR DEMOLITION OF A BUILDING" IS MANDATORY.
24. (E) BUILDING ENVELOPE COMPLIES WITH TITLE24 UNDER PREVIOUS SUBMITTAL.PROPOSED CHANGES DO NOT DECREASE ENVELOPE PERFORMANCE.
SYMBOL LEGEND: PROJECT DATA:
PROJECT TEAM:
SCOPE OF WORK: DEFERRED SUBMITTALS:
VICINITY MAP:
BUILDING CODES:2001 CALIFORNIA BUILDING CODE BASED ON THE 1997 EDITION OF THE UBC2001 CALIFORNIA PLUMBING CODE, BASED ON 2000 UPC2001 CALIFORNIA MECHANICAL CODE, BASED ON 2000 UMC2004 CALIFORNIA ELECTRIC CODE BASED ON 2002 NEC2005 BUILDING ENERGY EFFICIENCY STANDARDS2001 CALIFORNIA FIRE CODE
LEGAL JURISDICTION: CITY OF SAN JOSE, CASAN JOSE FIRE DISTRICT, CA
APN: 678-16-8
PLANNING ZONE: IP-B
CONSTRUCTION TYPE: V-N
BUILDING OCCUPANCY:B, F-1, S-2
FIRE PROTECTION: BUILDING IS PROVIDED WITH AUTOMATIC FIRE SPRINKLER SYSTEMTHROUGHOUT
SITE AREA: 29.88 ACRES
BUILDING AREA: 125,000 SF
AREA OF IMPROVEMENT: 125,000 SF
PARKING PROVIDED: SEE SHEET G0.04 FOR PARKING ANALYSIS
DEFERRED SUBMITTAL ITEMS SHALL BE REVIEWED AND APPROVED BY THEARCHITECT OR THE ENGINEER OF RECORD PRIOR TO SUBMITTAL FOR THEBUILDING OFFICIAL FOR APPROVAL.DEFERRAL OF ANY ITEM SHALL HAVE APPROVAL OF THE BUILDING OFFICIAL OFTHEIR DESIGN AND SUBMITTAL DOCUMENTS PRIOR TO ANY INSTALLATION.
1/ FIRE SPRINKLER SYSTEM2/ HIGH LEVEL STOCK RACK3/ BURN-IN CHAMBER SEISMIC ATTACHMENT4/ TOOLS INSTALLATIONS ARE TO BE UNDER SEPARATE PERMIT.
NEW WORK:
TENANT IMPROVEMENT OF OFFICE, STORAGE, ANDMANUFACTURING AREA. NEW TRASH ENCLOSURE, AND NEWEXTERIOR DOORS WILL BE INSTALLED.
DEMOLITION:
1. INTERIOR NON-STRUCTURAL PARTITIONS,FINISHES, FIXTURES, EQUIPMENT AS INDICATED ARETO BE REMOVED.
A0.0 Cover SheetA1.0 Demolition PlansA2.1 Floor Plan Level 1A2.2 Floor Plan Level 2A3.1 Ceiling Plan Level 1A3.2 Ceiling Plan Level 2A4.0 Exterior Elevations and Building SectionsA5.1 Interior Elevations - 1A5.2 Interior Elevations - 2A6.1 Finishes Plan Level 1A6.2 Finishes Plan Level 2A7.1 Furniture Plan Level 1A7.2 Furniture Plan Level 2A8.0 Door and Room/ Finishes SchedulesA9.0 Interior Details