Top Banner
TRi ChloRine GeneRaToR insTRuCTion Manual and WaRRanTy CaRd
28

TRi ChloRine GeneRaToR insTRuCTion Manual and ......The Zodiac TRi chlorine generator comes with two inbuilt timers that switch the filtration and chlorination system on and off as

Oct 23, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
  • TRi ChloRine GeneRaToR

    insTRuCTion Manual and WaRRanTy CaRd

  • 1

    Part: Qty: description:

    a. 1 TRiPowerpack

    b. 1 Chlorinegeneratingcell

    c. 1 Powerpackbracket

    d. 2 Reducingbushes

    This KiT ConTains:

  • 1

    WelCoMe To ZodiaC

    CongratulationsonyourpurchaseofaproductfromtheZodiacrangeofpoolcareproducts.Zodiacproductsaredesignedtoletyouspendmoretimeenjoyingyourpoolandlessonmaintenance.

    iMPoRTanT infoRMaTion

    YOUMUSTREADTHISINFORMATIONBEFOREINSTALLATION.ALWAYSREADTHELABELANDOPERATIONMANUALBEFOREUSING.PLEASEKEEPYOURMANUALASITCONTAINSYOURWARRANTY.

  • 2 3

    ZodiaC Believes in safeTy fiRsT

    AtZodiac,wetakesafetyseriously.Alwaysexercisecautionwhenusingelectricalappliancesandfollowtheinstructions.Failuretodosocouldresultinpermanentinjury,electrocutionordrowning.

    GeneRal WaRninGs

    Zodiacsaltwaterchlorinegeneratorsaredesignedfordomesticswimmingpooluseonly.Contraryusecouldaffectperformanceandvoidwarranty.

    Operatingachlorinegeneratorwithoutwaterflowingthroughthecellmaycauseabuildupofflammablegases,resultinginfireorexplosion.

    Keepequipmentoutofreachofchildren.

    Adamagedsupplycordshouldonlybereplacedbythemanufacturer,authorizedserviceagentorelectrician.

    Wheninstallingandusingthiselectricalequipment,alwaysfollowbasicsafetyprecautions.

    Beforeperforminginstallation,disconnectallpower.

    Forswimmingpools,Australianstandardsrecommendaminimumof1PartPerMillion(ppm)offreeavailablechlorinemustbemaintainedatalltimes.

    ServicetoZodiacequipmentshouldonlybecarriedoutbyqualifiedandauthorizedpoolprofessionals.

  • 2 3

    ZodiaC Believes in safeTy fiRsT

    Child safeTy

    Childrenshouldnotbeallowedtooperateorperformmaintenanceonthisproduct.

    Noone,particularlychildren,shouldsit,step,lean,orclimbonanyofyourpool’soperationalsystem.

    Intheinterestsofchildsafety,allcomponentsofapool’soperationalsystemshouldbelocatedatleast3.5metresawayfromthepool.

    eleCTRiCal haZaRd

    Toavoidaccidentalcontactwithlawnmowersandhedgetrimmers,powercordsshouldremainwithinsightandabovegroundatalltimes.

    TheZodiacTRIPowerpackmustnotcomeintocontactwithwaterandmustbeinstalledatleast3.5metresfromtheinsidewallofyourswimmingpool.

    Shouldalackofwaterbedetected,theunit’selectronicflowswitchisdesignedtoturnoffthesystem.Interferingwiththeelectronicflowswitchcouldresultinpersonalinjuryand/ordamagetothecell.

    Onepumpperelectricalsocketonly(noancillaryequipmentshouldbeconnectedtothesameoutlet).

    Thisapplianceisnotintendedforusebypersons(includingchildren)withreducedphysical,sensoryormentalcapabilities,orlackofexperienceandknowledge,unlesstheyhavebeengivensupervisionorinstructionconcerninguseoftheappliancebyapersonresponsiblefortheirsafety.

    Childrenshouldbesupervisedtoensurethattheydonotplaywiththeappliance.

    TheinstallationofthechlorinatorshouldbecarriedoutbyaqualifiedpersoninaccordancewiththeAustralianwiringrulesAS/NZS3000.

    Thechlorinatorpowerpackshouldbelocatedinthecorrectpoolzoneandconnectedtosupplyviaapoweroutletthatisprotectedbyaresidualcurrentdevice(RCD)havingaratedresidualoperatingcurrentnotexceeding30mA.ThepoweroutletshouldhaveadegreeofprotectionsuitableforthepoolzoneEnsurethatequipotentialbondingofallpartsofthepoolinstallationiscarriedout.

  • 4 5

    insTallaTion Guide

    ThefollowingstepswillhelpyougetupandrunningwithyournewZodiacTRiChlorinegenerator.

    PosiTioninG The PoWeR PaCK

    1. Locateasuitablespaceforthepowerpackbracket.Itshouldbeinstallednofurtherthan1.8metresawayfromthecell-ideallyinafiltrationshedorclosetothefiltrationequipment.

    PLEASENOTE:iffixingtoapostitmusthaveawaterproofpanelfitted(behindtheunit),atleast450mmwideand470mmhigh.

    2. Usingscrewsprovided,fastenthebracketsecurelytothewallandpositionthepowerpackonthebracket.Plugintopowerpoint,butdon’tturnonthepower.

    PosiTioninG The ChloRine GeneRaTinG Cell

    PLEASENOTE:Thecellshouldalwaysbethelastdeviceplacedonthewaterpipe(Inthereturnlinetothepool).

    3. Ensurethecellisplacedhorizontally,withtheInletpipeconnectingtothefittingclosesttothecelllead.

    4. Usingscrewbarrelfittings(supplied),attachthecelltothepipe.Ifusing40mmpipe,youwillneedtofitthecellusingthereducingbushes(alsosupplied).

    5. Whenconnectingtheleadfromthepowerpacktothecellmatchupthecorrespondingcoloursandpins,thenfittheendcap.

    (Note:EitherREDwirecanbeconnectedtoeitherREDpinontheelectrode.)

    6. PlugyourpoolpumpintotheoutletsocketinthebottomoftheTRi(thiswillallowtheTRitimertocontrolthefiltrationtimes)

    7. OnceallconnectionsaretogetherpressthemainspowerswitchtoON.

  • 4 5

    naviGaTion BuTTons

    UsethefollowingUIbuttonstoaccessandselectallmenusandcommands:

    on/off

    TurnUIpoweron/off.

    uP/doWn

    Scrollup/downwithincurrentmenutohighlightaspecificmenucommand.

    Menu/BaCK

    Entersintothemainmenu,andusedtogobacktopreviousmenu.

    seleCT/enTeR

    Select/enterscurrenthighlightedmenucommand.Displaythenextrelatedcommandoractivatetheselectedfunction

  • 6 7

    usinG inBuilT CloCK and TiMeRs

    Whenitcomestochlorination,everypoolisdifferent.Togetwhat’srightforyou,youwillneedtosettheunit’sclockandtimers.

    seTTinG The CloCK

    1. Switchpoweron.

    2. Waitforthestart-upsequencetocomplete.

    3. Pressthe buttontoentertheMAINMENU.

    4. Use / buttonsandscrolltoSETCLOCK.

    5. Press .

    6. Use / buttonstosetthehours.

    7. Press tosavethehours.

    8. Usethe / buttonstosettheminutes.

    9. Press tosavetheminutes.

    TRiwillthenreturntotheMAINMENU.

    10.Press toreturntotheoperatingscreen.

    NOTE:Thetimeisdisplayedin24Hourformat

  • 6 7

    TuRninG ChloRine GeneRaTion on

    ThechlorinegenerationoftheTRicanbecontrolledinanumberofways:

    1. Manuallysettoanoutputlevel,withtheoperatingtimesdeterminedbyanexternaltimer.

    2. Usingthein-builttimersontheTRiunit(referto‘TheTimers’)

    3. Usingaconnectiontoanexternalcontroller(referto‘Connectingtoacontroller’).

    Toturnthechlorinegenerationonmanually,presstheON/OFFbutton.Theoutputlevelcanbesetasdescribedin‘SettingtheChlorineOutput.’NOTE:Forsafetyreasons,theTRichlorinegeneratorwillcontinuallydosechlorineforamaximumof30hoursifleftrunningwithno‘OFF’time–unlessconnectedtoenexternalcontroller.Afterthistime

    theTRiwillswitchto‘OFF’.

    The TiMeRs

    TheZodiacTRichlorinegeneratorcomeswithtwoinbuilttimersthatswitchthefiltrationandchlorinationsystemonandoffasrequired.

    Duringswimmingseason,considerrunningthesystemforaround8hoursaday.Thiscanbeincreasedto10hoursduringperiodsofveryhotweather.

    Inwinter,itmayonlybenecessarytorunyourpool’sfiltrationsystemfor4hoursaday.Theseshorterperiodsofactivitywilllengthenthelifeoftheunit’selectrode.

    Forbestyearroundresults,settheunittooperateduringthecoolerhoursoftheearlymorning,eveningorwhenswimmersareusingthepool.

    PRoGRaMMinG The TiMeRs

    Toactivatethetimer,youwillneedtoenterbothanONandOFFtime.IfnoOFFtimeisentered,thechlorinegeneratorwillswitchoffatthedefaulttimeof12:00am(0:00).

    Youwillknowthatavalidtimehasbeenenteredwhena“T”SymbolisdisplayedinthetoprighthandcorneroftheLCDdisplaywhentheunitisdisplayingthe‘operatingscreen’.

    usinG inBuilT CloCK and TiMeRs

  • 8 9

    usinG inBuilT CloCK and TiMeRs

    Toprogramthetimer:

    1. Pressthe button.

    2. Press buttontomovearrowto‘SETTIMERS’.

    3. Press toenterthe‘SETTIMERS’menu.

    4. Press / toselectthetimeryouwishtoset.(Timer1orTimer2)

    5. Press .

    6. Press / tosetthehours(ontime).

    7. Press tosavethehours.

    8. Press / tosettheminutes(ontime).

    9. Press tosavetheminutes.

    10.Press / tosetthehours(offtime).

    11.Press tosavethehours.

    12.Press / tosettheminutes(offtime).

    13.Press tosavetheminutes.

    TRiwillreturntothe‘SETTIMERS’menu.

  • 8 9

    CleaRinG The TiMeRs

    Toclearthetimer:

    1. Pressthe button.

    2. Press / buttontoscrollto‘SETTIMERS’.

    3. Press toenterthe‘SETTIMERS’menu.

    4. Press / toscrollto‘CLEARTIMERS’.

    5. Press .

    Aconfirmationmessagewillappearonthescreen.

    exTeRnal TiMe CloCK

    Attimes,itmaybedesirabletocontrolchlorinegenerationusinganexternaltimeswitch.IfthechlorinegeneratoristurnedON,andtheexternaltimerfailstoswitchthemainspoweroffwithin30hours,theZodiacTRiwillautomaticallystopchlorinatinginordertopreventoverchlorination.

    Tosetthechlorinegeneratortorunfromanexternalclock:

    1. CleartheTimerbyfollowingtheprocedureoutlinedin‘ClearingtheTimers’.

    2. Pressthe buttontoturnthechlorinegeneratoron.

    usinG inBuilT CloCK and TiMeRs

  • 10 11

    seTTinG The ChloRine ouTPuT

    Theamountofchlorinerequiredbyyourpoolisdependentonanumberoffactorsincludingthesizeofthepool,thenumberofusersandtheclimate.

    Outputwillappearasapercentageonthescreenreadout,monitorthelevelaccordingtothereadingovertimewillhelpensureoptimumoutput.

    ForuserswhoupgradetotheTRi-PROmodel,chlorineoutputwillbecontrolledautomatically.

    TosetChlorineOutputlevels:

    1. Pressthe buttontoturnthechlorinegeneratoron.

    2. Pressthe / buttonstosetthedesiredoutputlevel.

    PLEASENOTE:ifusingapoolcoveryouwillneedtoreducethechlorineproductionsubstantially,pleaseuseLOWmodeifyouuseacover.SimplypressLOWbutton.

    ChloRine ouTPuT levels

  • 10 11

    CoRReCT seTTinGs foR youR TRi ConTRolled Pool

    fre

    e

    Ch

    lori

    ne

    (p

    pm

    )

    ph

    To

    tal

    alk

    alin

    ity

    (pp

    m)

    Cal

    ciu

    m

    hard

    ne

    ss

    (pp

    m)

    Cyan

    uri

    c a

    cid

    (p

    pm

    )

    sal

    t l

    eve

    l (p

    pm

    ) s

    en

    sors

    au

    stra

    lian

    sta

    nd

    ard

    1–3

    7.2–7.8

    80–300

    90–300

    30–50

    4000-7000

    ide

    al r

    ead

    ing/

    ran

    ge

    1–3

    7.5

    80–140

    90–300

    504000ppm

    at27ºC**

    To

    in

    cre

    ase

    *

    Add

    chlorine

    orincrease

    outputof

    equipm

    ent

    Addbuffer

    orsodaash

    (sodium

    carbonate)

    Add

    sodium

    bicarbonate

    Add

    calcium

    chloride

    Add

    Cyanuric

    acid

    AddSalt

    To

    de

    cre

    ase

    *

    Add

    muriatic

    acid

    Add

    muriatic

    acidor

    dryacid

    Partially

    drain

    &refillpool

    Partially

    drain

    &refillpool

    Partially

    drain

    &refillpool

    fre

    qu

    en

    cy o

    f te

    stin

    g (i

    n p

    eak

    se

    aso

    n)

    Weekly

    Weekly

    Weekly

    Weekly

    Weekly

    Monthly

    Quarterly

    Co

    RR

    eC

    T s

    eT

    Tin

    Gs

    fo

    R y

    ou

    R T

    Ri

    Co

    nT

    Ro

    ll

    ed

    Po

    ol

  • 12 13

    IfyouuseanautomationorcontrollersystemtocontrolyourpoolyouwillneedtoconfigureyourTRiChlorinegeneratortoallow“communication”betweenthetwo.

    you must set the controller type on the TRi before making the wiring connection.

    seTTinG The ConTRolleR (To be done before making a wiring connection)

    1. SwitchpowertotheTRiuniton.

    2. Waitforthestart-upsequencetocomplete.

    3. Pressthe button.

    4. Pressthe buttontoscrolldownto‘CONTROLLER’.

    5. Press toenterthecontrollermenu.

    6. Press / tohighlightthecontrollerbeingused.

    7. Press tosavethecontrollersetting.

    8. TRiwillreturntothemainmenu.

    9. Press toreturntotheoperatingscreen.

    ConneCTinG To a ConTRolleR

  • 12 13

    aTTenTion Jandy ‘Rev l’ oR laTeR useRs

    ItiscriticalthatthecontrollersettingbesettothecorrectZodiac,JandyorPentaircontrollerdesignation.ThereareanumberofdifferentrevisionslockedintotheTRisoftware.Pleaseseetheusermanualtodeterminethemodeland/orrevisionyouareusing.Iftheincorrectsettingisselected,damagecanbecausedtotheJandyAqualinkControlUnit.

    CauTion When WiRinG To a ConTRolleR

    IMPORTANT

    Wiringofthecontrollershouldbecompletedbyanauthorisedpoolequipmentinstaller.

    Beforeanywiringconnections/disconnectionsensuremainspowerisremovedfromboththecontrollerandtheZodiacTRiunit.

    Whenconnectedtoacontroller,theTRiChlorinegeneratoractsasthe‘slave’-respondingtorequests.Thismeanstimersettingsareignoredandtheoutputsettingscannotbechanged,althoughallother‘menu’functionsarestillaccessible,exceptforLOWandBOOSTmodes.

    WiRinG To a ConTRolleR

    ThefollowinginstructionsshouldbereadinconjunctionwiththeinstallationguideprovidedwiththeController.

    1. Removesilver‘dress’coverbypressinginatthesideswhereindicatedbelowandlift.

    2. Removethetwoscrewswhichattachthelowercovertothemainunit:

    ConneCTinG To a ConTRolleR

  • 14 15

    ConneCTinG To a ConTRolleR

    3. RemovethelowercoverfromtheTRiunit.NOTE:IfusingeitherpHupgradeorPROunit–carefullydisconnecttheribboncablefromtheTRiunit.

    4. RemovethesmallwhitebungclosesttothecentreofthelowerpaneloftheTRiunit.

    5. Threadthecontrollercablethroughthehole(agrommetmaybenecessarydependingonthesizeofthecablebeingused).

    6. Attachacabletietothecontrollercableasshowninthediagram.Thewiringcolourcodesareoutlinedbelow:

    DependingonthemakeoftheController,makethefollowingwiringconnections:

    Polaris eos / Jandy / Zodiac aqualink / aqualink TRi

    Greenwire(0V)to‘0V’terminalontheTRi

    Redwiretothe(+V)‘POS’terminalontheTRi

    Yellow/White(B)wireto‘B’terminalonTRi

    Blackwire(A)to‘A’terminalonTRi

    Pentair intellitouch

    GREENwireto‘B’terminalonTRi

    Redwireto‘POS’terminalonTRi

    Yellowwireto‘A’terminalonTRi

    Blackwireto‘0V’terminalonTRi

  • 14 15

    TesTinG The WiRinG ConneCTion

    OnceaconnectionhasbeenmadebetweentheControllerandtheChlorinegenerator,itwillneedtobetested.

    1. TurnonthepowertotheControllerandtheZodiacTRi.

    2. Ifsuccessful,a‘ ’symbolwillappearinthetoprighthandcornerofthescreenafterabout20seconds.

    3. Ifthecontrollerdoesnotconnect,turnpowerofftoboththedevicesandtryagain.

    veRify The WiRinG ConneCTions

    Toverifytheconnection:

    1. SwitchtheTRiunitonandcheckthecontrollersetting(followinstructionsunder‘SETTINGCONTROLLER’.

    2. Re-testtheconnection. Note:Forsafetyreasons,theZodiacTRirevertstotheOFFsettingifthecommunication

    connectionislost.

    ConneCTion To ConTRolleR foR Pool/sPa CoMBinaTions

    ToconnectaZodiacTRiunittoPoolorSpaValves,youwillneedtomakea“splice”intothecontrollinesfromtheController,locatedinsidethecontrolleritself.

    Forfurtherinformation,consulttheinstallationmanualoftheControllerbeingused.

    ConneCTinG To a ConTRolleR

  • 16 17

    Ifyourpoolhasacover,youshouldsettheoutputlevelto“low”.Thisisalsoknownas“winter”mode.

    Reducingyourchlorineoutputwillhelppreventdamagetoyourpool’scoverandotherequipment.

    Manual seTTinG

    1. ToselectLowmodepress .

    Thiswilldropthechlorineoutputtoaround10%.

    2. ‘Low’willappearonthescreen. Note:LoworWintermodecannotbeselectedwhenTRiisbeing

    controlledbyanexternalcontroller.

    auToMaTiC seTTinG

    TheZodiacTRicanbeconnectedtothevalvesofanautomaticpool/spasystem.

    Whentheinputfromthevalvesissetto‘Low’theTRiwillautomaticallyrevertto‘Low’modeandtheoutputwillbelockedat10%

    Detailsofthewiringconnectionareoutlinedinthe‘‘ConnectiontoAutomaticPool/SpaValve”sectionofthismanual.

    for users who have upgraded to the TRi-ph or TRi-PRo, the automatic ph/aCl control function is disabled when in loW mode.

    seTTinG The Mode To loW: Important If usIng a pool cover

  • 16 17

    Attimesyourpoolmayrequirealargerthannormalapplicationofchlorine.TheBoostfunctionisusedtorapidlyaddchlorine.

    InBOOSTor“Superchlorinate”mode,outputsettingsaretemporarilyoverriddenandthechlorinegeneratorrunsfor24hoursat100%ChlorineProduction.

    In‘TIMER’mode,thecirculationpumpwillrunfor24hours,beforeautomaticallyrevertingtopreviousoutput/timersettings.

    In‘MANUAL’mode,thechlorinegeneratorwillrunat100%foracumulativetotalof24hoursbeforerevertingtothepreviousoutputsetting.

    NOTE:

    The‘BOOST’modecannotbeengagedunderthefollowingcurcumstances:

    1) IftheTRiisinthe‘OFF’operatingmode.Thechlorinatormustbe‘ON’forBOOSTtobeengaged.

    2) IfyouhaveupgradedtotheTRi-PRO

    3) OrfromthefrontpanelwhentheTRiisbeingcontrolledbyanexternalcontroller.

    InmostcasesaBOOSTfunctioncanbesetfromthecontrollermenu.

    Consultyourthirdpartycontrollermanualformoreinformation.

    seTTinG The BoosT Mode

    ToactivatetheBOOSTsetting:

    Pressthe button.

    ‘BOOST’willbedisplayedonthescreenandchlorinegenerationwillcommence.

    The BoosT seTTinG

  • 18 19

    TheZodiacTRichlorinegeneratorautomaticallyprovidesanumberofinbuiltwarningsthatcanhelpidentifyproblemsandoffersolutions.

    ToaccesstheHELPmenu:

    1. Pressthe button.

    2. Usingthe / buttons,scrolltothe‘HELP/DIAG’menu.

    3. Press toenterthe‘HELP/DIAG’menu.

    4. Onceinthe‘HELP/DIAG’menu,usethe / buttonstoscrollto

    theerror/warningthathasbeendisplayed.

    5. Press .

    Anumberofsuggestedsolutionsaremomentarilydisplayed,inorderofpriority.

    Afterdisplaying,theTRiautomaticallyrevertsbacktothe‘HELP/DIAG’menu.

    6. Toexittothedefaultoperatingscreenwait~5seconds

    ORpressthe button.

    helP and TRouBleshooTinG

  • 18 19

    TokeepyourTRiUnitinthebestpossibleconditionitisrecommendedregularmaintenanceshouldbeperformed.

    insPeCTinG and CleaninG The eleCTRode

    InareasthatexperiencecalciumhardnesstheTRielectrodewillbenefitfromcleaning.

    Tocleanyourelectrode:

    1. Switchoffthefilterpumpandchlorinegenerator,closenecessaryvalvesandunplugthecellterminalcap.

    2. Unscrewtheretainingringandremovetheelectrode.Ifcalciumbuildupispresent,immersetheelectrodeincellcleaningsolutionwithoutimmersingtheterminals.

    3. WerecommendusingZodiacSaltChlorinatorCellCleanertocleantheelectrode.Howeveryoucanmixyourownbycarefullyaddingone(1)partofHydrochloric(Muriatic)acidtoten(10)partswater.Strongersolutionswillshortenterminallife.

    4. Allowthecleaningsolutiontodissolvethecalciumdepositsforabout10minutes.DisposeofthecleaningsolutionatanapprovedCouncilDepotandneverintostormwaterorsewagedrains.

    6. Rinsetheelectrodeincleanwaterandre-fittheelectrodeinthecellhousing.

    7. Replacethecellheadandplugassemblyandresetvalvesandswitches.TurnpumpandTRion.

    8. Confirmchlorineoutputandsettingsonthepowerpack.Timersettingswillbeautomaticallyretained.

    MainTenanCe

  • 20 21

    eRRoRs and WaRninGs. WhaT They Mean.

    no floW

    Diagnosis:Insufficientwaterflowinthecell.Thiscouldmeanthecirculationpumphasceasedtofunction,orthefilterneedscleaning.Thechlorineoutputwillbeturnedoffatthistime.

    CheCK salT

    Diagnosis:Saltlevelisbetween3000and4000ppm,dependingonthewatertemperature.

    Alwaysmaintainasaltlevelabove4000ppm.ifyoudon’tknowwhatyoursaltlevelisorhowtotestit,consultyourlocalpoolcareprofessional.

    CheCK PoWeR suPPly

    Diagnosis:Therecouldbeaproblemwiththepowersupply.Turnpoweroffatthepowerpointandconsultyourlocalpoolcareprofessional.

    CleaninG

    Diagnosis:Thecellisintheprocessofreversingpolarity.Waitapproximately5minutesandchlorineproductionshouldresumeasnormal.

  • 20 21

    TRouBleshooTinG

    additional information about this product can be found at zodiac.com.au

    Forfurtherinformationandassistancepleaseconsultyourlocalpoolprofessional.

    Your Local Dealer:

  • 22 23

    express Warranty*ZodiacGroupAustralia Pty Ltd (Zodiac australia)warrants that theZodiacTRiSaltwaterChlorineGeneratorwillbefreefromdefectsinmaterialsandworkmanshipfortheperiodof3yearsfromthedateofpurchase.

    * The warranty applicable to commercial application is limited to 12 months from the date of installation.

    Conditions

    1 Thisexpresswarrantyonly applies if theProducthasbeenpurchasedfromadealerauthorisedbyZodiacAustraliatosupplyit(authorised dealer).

    PurchasefromanAuthorisedDealerensuresthattheproductisagenuineZodiacproduct,thatitistheversiondesignedforAsiaPacificconditions,and that thePurchaserhasaccess toappropriate technicalknowledgeandadvice.

    2 ZodiacAustralia’s liabilityunder thisexpresswarranty is limited, at itsoption,totherepairorreplacementoftheProductorthepaymentofthecostofhavingtheProductrepairedorreplaced.

    3 Thisexpresswarrantydoesnotapplyinthefollowingcircumstances:

    (a)if the Product has not been installed in accordancewithZodiac’sinstallationinstructions;

    (b)iftheProducthasbeenmodifiedotherthanasauthorisedbyZodiacAustraliaorifacomponentparthasbeenreplacedbyapartthatisnotagenuineZodiacproduct;

    (c)if a defect results fromuse of the Product outside recommendedoperatingconditions;or

    (d)if a defect results from damage (including damage to any internalelectronics)causedbyapowersurgeorlightningstrike.

    Zodiac chlorinators are designed and tested in accordance withInternational Standard EN 61000-6-1 immunitymeasurements. Theyaredesignedtotolerateminorfluctuations(2000volts)inpowersupplythatcanbereasonablyexpectedtooccurintheenergygrid.Theywillnottoleratepowersurgesoutsidetheselimitsnorwilltheywithstandlightningstrikes.

    ZodiaC ausTRalia - exPRess WaRRanTy and GuaRanTees

  • 22 23

    ZodiaC ausTRalia - exPRess WaRRanTy and GuaRanTees

    4 Withoutlimiting3above,productssoldbyZodiacAustraliaaredesignedforusewithswimmingpoolwaterbalancedinaccordancewithAustralianStandardAS3633-1989withapHrangeof7.0-7.8.Maximumchlorinereadingsshouldnotexceed4ppm.Wherepoolwaterisnotmaintainedwithintheseparameters,ZodiacAustraliawillnotberesponsibleunderthisexpresswarrantyforanyresultingdamage,includingdamagecausedbycorrosion,scalingorstressloading.

    5 Replacementpartssuppliedunderthisexpresswarrantyarewarrantedtobefreefromdefectsinmaterialsandworkmanshipfortheremainderofthewarrantyperiodorfor12monthsfromthesupplyofthereplacement,whicheverislonger.

    6 WarrantyclaimsrelatingtoreplacementoftheelectrodesforLMseries,Cseries,DuoClearandDserieschlorinatorsaresubjecttothefollowingpro-ratapricingprocedure.ThePurchasermustpayforthereplacementelectrodeaproportionofthecostequaltothatproportionofthewarrantyperiod duringwhich theoriginal electrode functioned effectively. Thewarrantyperiodforthereplacementelectrodeistheremainderofthewarrantyperiodfortheoriginalelectrodeor12monthsfromthesupplyofthereplacement,whicheverislonger.ThePurchasermustpayfullcostforanyreplacementelectrodesafterthefirstreplacement.

    Product warranty registration

    7 PurchasersshouldregistertheirProductsassoonasconvenientlypossibleafterpurchasebycompletingaProductWarrantyRegistrationFormandpostingittoZodiacAustraliaattheaddressshownontheFormorbyregisteringonlineatwww.zodiac.com.au.

    8 Productregistrationmustoccur,andproofofpurchasemustbereceivedbyZodiacAustralia,priortoanywarrantyworkbeingapproved.Whereapplicable,aserialnumber,installationdateandnameofinstallerisrequiredaspartoftheregistrationprocess.

  • 24 25

    ZodiaC ausTRalia - exPRess WaRRanTy and GuaRanTees

    how to make a warranty claim

    9 ThePurchasermusttelephoneoremailZodiacAustraliaCustomerServiceandobtainawarrantyIDnumberforthewarrantyclaim.

    Contactdetailsare:

    Zodiac Group australia Pty ltd 219WoodparkRoadSmithfieldNSW2164

    Customer service Telephone:1800688552Emailaddress:[email protected]

    10ZodiacAustralia reserves the right to determine, in relation to eachwarrantyclaim,whethertheProductshouldbereturnedtotheAuthorisedDealerat theaddresswhere thePurchaserpurchased theProductorwhetherwarrantyservicewillbeprovidedinthefield,repairedataZodiacworkshoporatthepremisesofanauthorizedZodiacwarrantyagent.

    11 IfitisnecessaryforthePurchasertoincurfreightchargesinmakingavalidclaimunderthiswarranty,ZodiacAustraliawillreimbursethePurchaserforchargesreasonablyincurreduponproofofthecharges.

  • 24 25

    ZodiaC ausTRalia - exPRess WaRRanTy and GuaRanTees

    additional guarantees, rights and remediesaustralian Purchasers - Guarantees under the australian Consumer law

    12Thebenefitsofthisexpresswarrantyareinadditiontootherguarantees,rights and remediesAustralian consumers have under theAustralianConsumerLaw.

    13ZodiacAustraliaproductscomewithguaranteesthatcannotbeexcludedundertheAustralianConsumerLaw.Youareentitledtoareplacementorrefundforamajorfailureandforcompensationforanyotherreasonablyforeseeablelossordamage.Youarealsoentitledtohavethegoodsrepairedorreplacedifthegoodsfailtobeofacceptablequalityandthefailuredoesnotamounttoamajorfailure.

    Purchasers in other Countries

    14ThelawsandregulationsofothercountriesmayconferonPurchasersinthosecountriesadditionalrightsandremedies.Totheextentthattheycannotbeexcludedormodified,Purchasershavethebenefitsofthoserightsandremediesinadditiontothebenefitsofthisexpresswarranty.Tothefullextentthatitispermissibletodoso,thoseadditionalrightsandremediesareexcludedormodifiedsoastobeconsistentwithZodiacAustralia’sexpresswarranty.

    inConsisTenCy WiTh WaRRanTy sTaTeMenTs in PRoduCT Manuals oR oTheR doCuMenTs aCCoMPanyinG PRoduCTs

    Ifanywarrantystatements inaZodiacAustraliaproductmanualorotherdocumentareinconsistentwiththeaboveExpressWarrantyandGuarantees,theaboveoverridesandreplacestheinconsistentstatements.

  • ZodiacisaregisteredtrademarkofZodiacGroupAustraliaPtyLtdABN87002641965

    ZodiaC CusToMeR seRviCe CenTRe

    ZodiacGroupAustralia:

    219WoodparkRd,Smithfield,NSW2164Australia

    Tel:1800688552Fax:1300781688

    Email:[email protected]

    Duetoconstantdevelopmentsandimprovements,specificationsmaychangewithoutnotice.

    Improperusecouldaffectperformanceandvoidwarranty.

    ©CopyrightZodiacAustraliaLtd2013

    W176781REV.A