Trapper II Engineered Thermoplastic Grease Trap ™ w e N fi i t r e C d e n g i s e D Wet Inlet 10 through 100 GPM Heavy Duty Polyethylene • One man installation • Won’t rust out • Thick kitchen-duty cover • Structural ribs for above or below grade Low Maintenance Cost • Large grease storage • Large sediment storage • Designed for quick cleaning Three Outlet Options • Eases unforeseen piping hassles • Built in test caps • Makes ordering easy Built In Flow Control • No external flow control needed • No flow control venting needed • Reduces installation footprint
2
Embed
Trapper II brochure 11-06 - PEP Plastic · Trapper II Engineered Thermoplastic Grease Trap ™ N D Wet Inlet 10 through 100 GPM Heavy Duty Polyethylene • One man installation •
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Trapper IIEngineered Thermoplastic Grease Trap
™weN
fiitreC
de ngiseD
Wet Inlet10 through 100 GPM
Heavy Duty Polyethylene• One man installation• Won’t rust out• Thick kitchen-duty cover• Structural ribs for above or below grade
Low Maintenance Cost• Large grease storage• Large sediment storage• Designed for quick cleaning
Three Outlet Options• Eases unforeseen piping hassles• Built in test caps• Makes ordering easy
Built In Flow Control• No external fl ow control needed• No fl ow control venting needed• Reduces installation footprint
2500 South 170th StreetNew Berlin, Wisconsin 53151tel: 1-800-827-7119fax: 1-800-827-9664www.schierproducts.com
Maintenance clearance height: Allow 8” from top of tank to remove cover and internal parts.
Trapper II™ Wet Inlet
Design Features
• Built in fl ow control • Low annual maintenance cost • Heavy duty polyethylene • Above or below grade • Unique fl ow pattern • Stainless steel cover bolts • Three outlet options • Cover gasket won’t rot or fl atten
Unique Flow Pattern
The Trapper II’s inlet and outlet diff users create a unique fl ow pattern, allowing grease to collect at the surface, sediment to drop, and gray water to pass through.A built in fl ow control is located inside the inlet diff user and is easily cleanable. It does not require an external fl ow control fi tting.
The Trapper II is provided with an internal air relief on the outlet diff user and does not require venting at the unit wall. All units are sewer gas traps.
W
L
E
H
A
C
B
D
Trapper II models PATG-2025 and PATG-3050 have been certifi ed by NSF to the ASME Standard #A112.14.3. These models are compliant with the International Plumbing Code and the Uniform Plumbing Code. Certifi cations for other models are pending.