Top Banner
Physics 401, Spring 2014. Eugene V. Colla
25

Transients and Oscillations in RLC Circuits(v2m)

Nov 23, 2015

Download

Documents

Transients and Oscillations in RLC Circuits(v2m)
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
  • Physics 401, Spring 2014.Eugene V. Colla

  • Transients and Oscillations in RLC Circuits.

    Outline

  • Main goals of this week Lab:

  • Transients. Definition.

    transient ( physics ) a short-lived oscillation in a

    system caused by a sudden change of voltage or

    current or load

    a transient response or natural response is the

    response of a system to a change from equilibrium.

    System under

    study

  • Transients in RLC circuit.

    R

    L

    C

    Vscope

    Resistance R [Ohm]

    Capacitance C [uF] (10-6F)

    Inductance L [mH] (10-3H)

  • Transients in RLC circuit.

    R

    L

    C

    V(t)scope

    VR VL

    VC

    According the Kirchhoffs law VR+VL+VC=V(t)

    -1.0 -0.5 0.0 0.5 1.00.0

    0.5

    1.0

    V(t

    )

    time

    V0

    2

    2

    d d q(t)L q(t) +R q(t) + = 0

    dt dt C*See Lab write-up for details

    *

    (1)

  • Transients in RLC circuit. Three solutions

    The solution of this differential

    equation can be found in the form ( ) estq t A

    This will convert (1) in

    quadratic equation

    Rs s

    L LC

    21

    0

    ,

    ,

    R Rs a b

    L L LC

    R Ra b

    L L LC

    2

    1 2

    2

    1

    2 2

    1

    2 2

    with solutions:

    b2>0 over-damped solution

    b2=0 critically damped solution

    b2

  • Transients in RLC circuit. Over-damped solution:

    b2>0

    ( ) e at bt btq t A e B e1 1

    In this case the solution will be aperiodic

    exponential decay function with no

    oscillations:

    ( ) ( ) ( )at bt bt at bt btdq

    i t ae A e B e be A e B e

    dt1 1 1 1

  • Transients in RLC circuit. Over-damped solution:

    b2>0

    Taken in account the initial conditions: q(0)=q0 and i(0)=0

    ( ) cosh sinhata

    q t q e bt bt

    b0

    ( )( ) a b tq a b

    i t e

    b

    2 2

    0

    2

    This is exponential decay function

    -( - )

    ( - )

    a b t

    a b t

    q ae

    b

    0

    11

    2

  • Transients in RLC circuit. Critically-damped

    solution b2=0

    For this case the general solution can be found as

    q(t)=(A2+B2t)e-at. Applying the same initial condition

    the current can be written as i=a2q0te-at

    Critical damped case shows the

    fastest decay with no oscillations

    2 2 40

    Lb R

    C

    Critically-damped

    conditions for our

    network2

    Ra

    Land

  • Transients in RLC circuit. Critically-damped

    solution. Real data analysis. b2=0

    In this experiment R=300 ohms,

    C=1mF, L=33.43mH.

    The output resistance of Wavetek is 50 ohms and

    resistance of coil was measured as 8.7 ohms, so actual

    resistance of the network is Ra=300+50+8.7=358.7

    Decay coefficient =

    =

    .

    .

  • Transients in RLC circuit. Critically-damped

    solution. Real data analysis. b2=0

    Now the experimental results:

    Calculated decay

    coefficient ~5385,

    Obtained from fitting -

    ~5820.

    Possible reason it is still slightly over damped

    Calculated b2 is

    b2=2.99e7-2.90e7>0

    Vc ~q, fiiting function: Vc=Vco(1+at)e-at

  • Transients in RLC circuit. Under-damped

    solution. If b2

  • Transients in RLC circuit. Under-damped solution.

    Log decrement. Quality factor.

    Log decrement can be defined as = (

    (+=

    += , where T1=1/f1

    Quality factor can be

    defined as =

    ,

    For RLC =

    =

    From this plot d0.67Q4.7 -1 0 1 2 3 4 5 6 7 8 9 10

    -6

    -3

    0

    3

    6

    3.529

    1.809

    0.929620.47494

    VC (

    q/C

    ) (V

    )

    time (ms)

  • Transients in RLC circuit. Data analysis. Using

    Origin software.

    1. Pick peaks

    2. Envelope

    3. Exponential term

    4. Nonlinear fitting

    -1 0 1 2 3 4 5 6 7 8 9 10-6

    -3

    0

    3

    6

    0.00115

    0.0023

    0.003460.00463

    VC (

    q/C

    ) (V

    )

    time (ms)

    f=862Hz

    -1 0 1 2 3 4 5 6 7 8 9 10-6

    -3

    0

    3

    6

    VC (

    q/C

    ) (V

    )

    time (ms)

    f=862Hz

  • Transients in RLC circuit. Under-damped solution.

    Log decrement. Quality factor.

  • Transients in RLC circuit. Data analysis. Log

    decrement. Using Origin software. Results.

    Time domain trace

    Points found using Find peaks

    Envelope curve

  • Transients in RLC circuit. Data analysis. Log

    decrement. Using Origin software. Results.

    Fitting the envelope data to exponential decay function

  • Transients in RLC circuit. Data analysis.

    (1/T)2 vs 1/C experiment.

    Zero crossing points

    0ffsetManual evaluation of the

    period of the oscillations

    in( )atq(t) Ae s t offset

    Limited accuracy

    Results can be

    effected by DC offset

  • Transients in RLC circuit. Data analysis.

    (1/T)2 vs 1/C experiment. Using Origin software.

    in( )atq(t) Ae s t

    Limited

    Use Origin standard

    function

    Category: Waveform

    Function: SineDamp

    Fitting function ; y0,A,t0 xc, w fitting parameters

  • Transients in RLC circuit. Data analysis.

    (1/T)2 vs 1/C experiment. Using Origin software.

    in( )atq(t) Ae s t

    Limited

    Data plot + fitting curve

    Residuals - criteria

    of quality of fitting

  • Transients in RLC circuit. Data analysis.

    (1/T)2 vs 1/C experiment. Using Origin software.

    in( )atq(t) Ae s t

    Final results

    Rf

    T LC L

    2 2

    21 1 1

    2 2

  • Resonance in RLC circuit.

    R2

    L

    C VCV(t)

    100 1000 100000

    2

    4

    6

    8

    10

    12

    14 1904.83204

    UC

    f (Hz)

    f=1500Hz

    =

    =

    = .

  • Origin templates for this week Lab.

    Open template

    button

    \\engr-file-03\phyinst\APL Courses\PHYCS401\Common\Origin templates

  • Origin manuals

    Very short and simple manual which covers

    only main general operations with Origin.

    Document located on server and there is a

    link from P401 WEB page

    There are also manuals from OriginLab.

    Video Tutorials at the

    site of the company

    http://www.originlab.com/index.aspx?go=SUPPORT/VideoTutorials

    Do not forget about

    Origin Help

    \\engr-file-03\phyinst\APL Courses\PHYCS401\Common\Origin manuals