TRANSFORMADORES DE CORRIENTE ENCAPSULADOS EN RESINARESIN-CASE
CURRENT TRANSFORMERS
TM TW
TRANSFORMADORES DE CORRIENTE CON CARCASA DE PLSTICOCURRENT
TRANSFORMERS WITH PLASTIC CASE
TSRSumador / Adding
TCMConvertidor incorporado
Built-in converter
Rail DIN DIN Rail
TA TASClase / Class: 0,2S
TEAdaptador impedancia
Impedance adapter Convertidor incorporado / Built-in
converter
Panel Panel
TI TP-420 TCB
TRPMMedida + Proteccin
Measuring + Protection
Rail DIN DIN Rail
TRPProteccin / Protection
TRMMedida / Measuring
Pg. / Page55
Pg. / Page15
Pg. / Page15
Pg. / Page46
Pg. / Page62
Pg. / Page59
Pg. / Page38
Autosoportante Self-fixing
WJ
Pg. / Page33
Pg. / Page16
Pg. / Page21
TPNucleo partido / Split-core
Pg. / Page35
TABClase / Class: 0,2
Pg. / Page25
TACClase / Class: 0,5S
Pg. / Page29
Pg. / Page40
Pg. / Page48
Pg. / Page44
Pg. / Page42
-
M.7 / 3
Tran
sfor
mad
ores
de
corr
ient
e. M
edid
a y
prot
ecci
nINTRODUCCINAl mismo tiempo que se iniciaba el uso de la
corriente elctrica, naca la necesidad de lostransformadores de
medida. En este catlogo nosreferiremos a los transformadores de
corriente.
Las prestaciones que debe cumplir un transformadorson las
siguientes:
- Aislar y separar los circuitos y aparatos de medida,
proteccin, etc., de las lneas de alta tensin
- Evitar perturbaciones generadas por el transporte de elevadas
corrientes
- Reducir corrientes de cortocircuito a valores admisibles en
delicados aparatos de medida y proteccin
- Obtener intensidades de corriente, o tensiones, proporcionales
(por lo menos en un determinado rango) a las que se desea medir o
vigilar, para transmitirlas a los aparatos apropiados
La experiencia demuestra queuna mala eleccin o instalacinde los
transformadores de medida / proteccin puedeprovocar situaciones de
un mal funcionamiento de lainstalacin, as como que no quede
garantizada laseguridad, tanto del personal como de la
instalacin,en los momentos crticos.
ELECCINPara la correcta eleccin de un transformador de
medida (medida o proteccin) deberemos conocer:
- La aplicacin a la que va destinado (medida o proteccin)
- Caractersticas del entorno de trabajo, o condiciones de uso
(interior o exterior, temperatura mxima de trabajo, etc.)
- La caractersticas de la lnea donde vayamos a instalarlo:
Dimensiones del cable o pletina Margen de medida de la corriente
a medir
(corriente mxima, mnima, a medir) Sobrecarga (rango y tiempo)
Tensin de la red (baja, media o alta tensin) Corriente de
cortocircuito Frecuencia de red- Caractersticas del instrumento o
rel asociado
(precisin, corriente nominal, consumo, etc.)- Distancia entre el
transformador y el instrumento,
as como la seccin de cable utilizado en la conexin
INTRODUCTION
At the same time that the use of electrical energybegan, the
need of measuring transformers arose. Inthis catalogue well refer
current transformers
Services that transformers must deliver are:- Isolation and
separation of circuits and equipment
for measuring, protection, etc, from high voltage power
lines.
- To avoid disturbances due to carrying high currents
- Reduction of short-circuit currents up to admissible values
for sensitive protection and measuring equipment
- To obtain currents and voltage values proportional to those
wanted to be measured or monitored in order to be sent to
appropriate measuring instruments
The experience demonstratesthat a bad selection orinstallation
of measuring/protective transformers canprovoke either
malfunctioningevents in the installation as well
as the impossibility of guarantying a proper operationof
protection systems at critical moments.
CHOICE
For a proper selection of a measuring transformer(measuring or
protective) we must know:
- The ending application (measuring or protection)- Main
characteristics of the working environment or
use conditions (inner or outdoor, maximum working temperature,
etc.)
- Main characteristics of the power line the transformer will be
connected to:
Dimensions of the cable or bus-bar Measuring range of the
current to be measured
(maximum, minimum current to be measured) Overload (level and
duration) Mains nominal voltage (low, medium or high
voltage) Short-circuit current Mains nominal frequency- Main
characteristics of the instrument or relay
associated to the transformer (accuracy, rated current, rated
output, etc.)
- Distance between transformer and the associated instrument, as
well as the cross-section of the cable used for the link between
both elements
-
Curr
ent
tran
sfor
mer
s. M
easu
ring
and
pro
tect
ion
M.7 / 4
INSTALACINEl transformador est formado por uno o ms
primarios (indicados como P1 / K , P2 / L), uno o mssecundarios
(S1 / k , S2 / l) y un ncleo de materialferro-magntico. (Fe-Si,
Fe-Ni, etc.).
El primario en un transformador barra pasante serla propia
pletina de la instalacin. En un transformadorprimario bobinado, el
primario ya est bobinado en eltransformador, con lo que el
transformador dispone deunas pletinas para conectarlo a la
instalacin.
En la instalacin tenemos un sentido de consumo(de acometida a
carga) y un sentido de generacin(de generador a acometida).
Con estas dos premisas, la conexin la realizaremoscolocando el
P1 del transformador hacia la acometiday el P2 hacia la carga. Los
secundarios losconectaremos respetando la indicacin S1 y S2
detransformador e instrumento.
Una instalacin donde se invierta la polaridad deltransformador,
provoca invertir 180 la fase decorriente. Los instrumentos o
analizadores de redesdonde est instalado este transformador
generarnmedidas incorrectas en las magnitudes donde influyael ngulo
de fase (potencia, energa, factor depotencia), no as para la medida
de la intensidad decorriente o tensin.
NORMATIVA APLICADA
Los transformadores estn diseados, contruidos yverificados bajo
los criterios de las siguientes normas:
- IEC 44-1 (sustituye a la IEC 185)- UNE 21088- BS 7626
Las caractersticas que definen un transformadorde corriente
son:
- Relacin de transformacin ( Ipn / Isn )- Clase de precisin /
Potencia de precisin- Tensin de red / aislamiento- Factor de
seguridad / Factor lmite de precisin- Frecuencia de trabajo-
Temperatura de trabajo ( Clase trmica )- Corriente de cortocircuito
( trmica y dinmica )- Gama extendida ( margen de medida por
encima
del 100 % )- Caractersticas de la envolvente (
autoextinguible
V0 )
CARACTERSTICAS DE UNTRANSFORMADOR
INSTALLATION
The transformer is formed by one or more primarywindings (marked
as P1 / K, P2 / L), one or moresecondary windings (marked as S1 / k
, S2 / l) and acore of ferro-magnetic material (Fe-Si, Fe-Ni,
etc.).
The primary is the own bus-bar of the installation incase of a
passing bar transformers. For woundprimary transformers, the
primary is already woundinside the own transformer, thus these
transformersare equipped with suitable holding pieces for their
finalassembly to the installation.
At any power system a consumption direction isstated (from power
utility incoming mains to loads) aswell as a generation direction
is (from generators topower utility incoming mains). According to
this basis,the P1 side of the transformer will correspond to
thepower utility incoming mains side and the P2 side ofthe
transformer will correspond to the load side. Forthe secondary
output terminals, a correspondencebetween S1 and S2 indications in
the transformer andthe associated instrument must be followed.
In case that the polarity of the transformer isinverted, the
phase angle of the current is inverted by180, therefore, measuring
instruments or networkanalyzers whose current signal is supplied by
thistransformer will give incorrect readouts for suchmagnitudes
whose calculation process depends onthe phase angle (power, energy,
power factor), butvoltage and current readouts will be correct.
RELEVANT STANDARDS
Transformers are designed, made and testedaccording to following
harmonized standards:
- IEC 44-1 (replaces IEC 185)- UNE 21088- BS 7626
MAINS FEATURES OF ATRANSFORMER
Main features that define a transformer are thesefollowing
listed:
- Transformation ratio ( Ipn / Isn )- Accuracy class / Rated
output- Highest voltage for equipment / insulation- Security factor
/ Accuracy limit factor- Working frequency- Working temperature (
Thermal class )- Short-circuit current ( Thermal and dynamical )-
Extended current rating ( measuring range over
100 % )- Case characteristics (V0 self-extinguishing)
-
M.7 / 5
Tran
sfor
mad
ores
de
corr
ient
e. M
edid
a y
prot
ecci
n
La clase de precisin define el error mximo que puedeintroducir
el transformador tanto en corriente (%) comoen ngulo (minutos) y
siempre relacionado a unapotencia nominal expresada en VA, y al
rango deintensidad de corriente de primario en el que
estemostrabajando. (ver tabla)
Las clases de precisin tpicas, para medida, son:0.2, 0.5, 1, 3,
0.2s, 0.5s (IEC 44.1)
Las clases de precisin tpicas, para proteccin,son: 5P, 10P (IEC
44.1)
The accuracy class defines the maximum errorintroduced by the
transformer either in current (%) as inangle (minutes) and related
always to a rated output inVA and to the existing primary current
rate. (see table)
Standard accuracy classes for measuring usageare: 0.2, 0.5, 1,
3, 0.2s, 0.5s (IEC 44.1)
Standard accuracy classes for protection usageare: 5P, 10P (IEC
44.1)
Clase de precisin / Accuracy class
Es la mxima potencia que es capaz de suministrar eltransformador
dentro de una determinada clase deprecisin. La unidad se expresar
en VA. La potenciaconsumida, la calcularemos como suma del consumo,
enVA, del instrumento de medida o rel de proteccin mslas prdidas en
el cable de conexin (contando recorridototal).
La potencia de precisin debe ser igual o superiora la potencia
consumida, dentro de la clase deprecisin deseada
Es aconsejable que la carga total que ve eltransformador este
comprendida entre el 25 % y el100 % de la carga nominal de
precisin.
Potencia de precisin / Rated output
This is the maximum power that the transformer candeliver within
a certain accuracy class. This power will beexpressed in VA. The
consumed burden will becalculated as the addition of the measuring
instrument orprotection relay burden in VA plus the losses in
theconnection cable (taking into account the total distance).
The rated output must be equal or higher than theconsumed burden
within the required accuracyclass.
It is highly recommended that the total burden atthe transformer
output is comprised between 25 % to100 % of the rated output.
Es la mxima tensin de red donde podemos instalar eltransformador
de corriente. La tensin de aislamiento esla tensin de pico, eficaz,
que debe soportar, durante 1minuto.
Para una tensin de red mxima de 720 V la tensinde aislamiento es
de 3 kV (IEC 44.1)
This is the maximum voltage of the mains thetransformer will be
connected to. The insulation voltageis the peak r.m.s. voltage that
the transformer mustwithstand during 1 minute.
For a maximum usage voltage of 720 V~, theinsulation voltage is
of 3 kV~ (IEC 44.1)
Tensin de red - Tensin de aislamiento / Highest voltage for
equipment - Insulation voltage
La corriente de primario (Ipn) la seleccionaremos enfuncin de la
mxima corriente permanente de la lneaque queremos medir. (1 A ...
5000 A. Es posible otrosvalores).
La corriente de secundario (Isn) la seleccionaremos enfuncin de
la corriente mxima, permanente, delinstrumento de medida asociado
(normalizados 5 A y1 A, es posible otros valores).
Para medida de corrientes de bajo nivel
necesitaremostransformadores de primario bobinado (ver
aplicacionesespeciales).
Es aconsejable utilizar el transformador dentro deun rango de
corriente entre 20 y 100 % de sucorriente nominal (para clases 0.2
s, 0.5 s entre 5 %y el 100 %, ver tabla)
Relacin de transformacin (Ipn / Isn) / Transformation ratio (Ipn
/ Isn)
The primary current (Ipn) must be selected according tothe
maximum permanent current carried along the line tobe monitored. (1
A ... 5000 A, other values are alsopossible).
The secondary current (Isn) must be selected accordingto the
maximum permanent incoming current of theinstrument the transformer
is supplying (5 A and 1 A arestandard values, other values are also
possible).
Wound primary transformers will be required for themeasurement
of low value currents (see specialapplications).
It is highly recommended to use the transformer formeasuring a
current within a 20% to 100 % of itsrated primary current (for
classes 0.2 s and 0.5 swithin 5 % to 100 %, see table)
-
Curr
ent
tran
sfor
mer
s. M
easu
ring
and
pro
tect
ion
M.7 / 6
En las aplicaciones de proteccin nos interesa detectarpuntas de
corriente, no permanentes, esto implica que elmargen de medida, en
los transformadores deproteccin, no ser del 0 100 % de la
corrientenominal, sino, entre el 100 % y el valor que defina
elfactor lmite de proteccin.
Este valor queda definido, en transformadores deproteccin despus
de la P (ejemplo 5P10).
Los valores normalizados son 5, 10, 15, 20, 30.
For protection applications, unsteady current peaks arewanted to
be detected, which implies that the measuringrange of protective
transformers will not be within 0 100% of the rated current, but,
between the 100 % and thevalue that sets the protection limit
factor.
This value is defined in the protective transformerfollowing the
P mark (example 5P10).
Standard values are 5, 10, 15, 20, 30.
Factor lmite de precisin (tranf. de proteccin) / Accuracy limit
factor (protective transformers)
Define la mxima temperatura que puede soportar eltransformador,
sin sufrir ninguna deformacin o malfuncionamiento. Esta temperatura
la obtendremos comosuma de una temperatura ambiente mxima (45 C) y
unincremento de temperatura mximo, generado por elbobinado. (ver
tabla)
La clase trmica normalizada es: A (105 C) paratransformador de
envolvente de plstico. Paraenvolvente de resina: A (105 C) o B (130
C).(IEC 44-1)
This point defines the maximum temperature that thetransformer
can withstand with suffering no electrical ormechanical damage.
This temperature will be determinedas the addition of a maximum
ambient air temperature(45 C) and a maximum temperature rise
provoked bythe inner winding (see table).
The standard thermal class for plastic casetransformers is A
(105 C). For resin casetransformers are A (105 C) or B (130 C) (as
per IEC44-1).
Clase trmica (Temperatura de trabajo) / Thermal class (Working
temperature)
El factor de seguridad define un valor de corriente deprimario,
mximo, a partir del cual el transformadorqueda saturado, es decir,
la corriente de secundario noaumentar aunque aumente la del
primario. Este valor sedefinir para la potencia nominal, y es
inversamenteproporcional a la carga del transformador.
La seguridad del instrumento alimentado por eltransformador es
tanto mayor cuanto menor sea elvalor del factor de seguridad. Para
instrumentos demedida el valor estandarizado es Fs < 5
Factor de seguridad (Fs) (transf. de medida) / Security factor
(Fs) (measuring transformers)
The security factor defines a maximum value of thecurrent at the
primary side from which the transformergets saturated, that is, at
this saturation point thesecondary current will not increase though
the primarycurrent increases. This value will be set for the
ratedoutput, and it is inversely proportional to the
transformerburden.
The safety of the instrument supplied by thetransformer is
greatest when the value of the ratedinstrument security factor is
small. The standardvalue for measuring instruments is set at Fs
< 5.
Define el comportamiento del transformador frente a losesfuerzos
dinmicos y trmicos provocados por uncortocircuito en la lnea donde
est instalado.
La corriente trmica (Ith) normalizada es 60 Ipn (80Ipn) durante
1 s, la corriente dinmica (Idyn) 2.5 Ith.
This current defines the behaviour of the transformeragainst
both thermal and dynamic forces provoked by ashort-circuit event at
the installation point.
Corriente del cortocircuito (trmica y dinmica) / Short-circuit
current (thermal and dynamic)
Es el margen de la corriente de entrada, en el que
eltransformador puede funcionar a rgimen permanente,manteniendo
todas sus caractersticas (precisin,calentamiento, aislamiento,
etc.)
Si no se especifica ningn valor de gama extendida,el valor es
100 % de Ipn. Los valores tpicos son120 %, 150 %, 200 %
The primary current range for which the transformer canoperate
in a steady state also keeping all its features(accuracy,
temperature rise, insulation, etc.)
Gama extendida (Extd.) / Extended current rating (Extd.)
The standard thermal current (Ith) is set at 60 Ipn(80 Ipn)
during 1 s, whilst the dynamic current (Idyn)is set at 2.5 Ith.
Whether no extended range value is defined, thisvalue is set at
100 % of Ipn. Other standard valuesare 120 %, 150 %, 200 %.
-
M.7 / 7
Tran
sfor
mad
ores
de
corr
ient
e. M
edid
a y
prot
ecci
nAPLICACIONES
1- Aumentar la potencia de untransformador manteniendo la clase
deprecisin.
Si queremos aumentar la potencia que suministra untransformador,
manteniendo la clase de precisin (porejemplo un TA 100B para 100/5
A da una potencia de5 VA en clase 1 y queremos que d 10 VA en
clase1), podemos conectar en serie dos o mstransformadores de igual
relacin y caractersticas,respetando las polaridades tanto de
primario como desecundario. Los bornes de salida ser el S1
delprimer transformador y el S2 del segundotransformador. (Ver
figura 1).
El resultado final es un transformador de igualrelacin, igual
clase de precisin y de potencia:la suma.
2- Medida de corrientes de bajo nivel.(transformadores primario
bobinado)
La medida de corrientes de bajo nivel (desde mAhasta 50 A) viene
limitada por dos caractersticas:
- Ventana del ncleo magntico- Prestaciones (material, calidad)
del ncleo
magntico
El material ms utilizado para transformadores demedida es de una
aleacin de Fe-Si con unascaractersticas de poca linealidad en la
parte baja dela curva magntica (correspondientes a corrientesbajas)
y un nivel alto de induccin (sobre 1.7 Teslas),antes de la
saturacin (capacidad de suministrar unaelevada potencia. Esta
caracterstica lo haceespecialmente indicado para aplicaciones
deproteccin).
Este material nos permite, a un coste relativamentebajo y unas
dimensiones reducidas, obtener unasbuenas prestaciones de potencia,
precisin ylinealidad, siempre y cuando nos alejemos de la partebaja
de la curva magntica.
APPLICATIONS
A: Instalacin / InstallationB: Aparato medida / Measuring
instrument
A
B
1- Rise of a transformer burden keepingthe accuracy class
Whether the rated output of a transformer is requiredto be
increased but also keeping the rated accuracyclass (for instance, a
TA 100B for a ratio of 100/5 Adelivers an apparent power of 5 VA in
class 1, but anapparent power of 10 VA in class 1 is required),
twoor more transformers with the same transformationratio and
characteristics can be serial connected,provided primary and
secondary polarities arerespected. Output terminals will be then
the S1 of thefirst transformer and S2 of the last one. (See figure
1).
The final result will be a transformer with the samerated ratio,
accuracy class and a rated output equal tothe addition of each
individual rated output.
2- Measuring low range currents. (woundprimary transformers)
The measurement of low range currents (from mA to50 A) is
basically limited by two features:
- Window of the magnetic core.- Properties of the magnetic core
(material, quality).
The most commonly used material for measuringtransformers is an
alley of Fe-Si that delivers a lowlinearity at the low part of the
magnetic curve(associated to low range currents) and a
highinduction level (about 1.7 T) before the saturationpoint
(ability to supply a high burden, which makes thismaterial to be
especially suitable for protectionapplications).
This material permits to get a relatively low costtogether with
reduced dimensions; as well as to obtaingood features related to
rated output, accuracy andlinearity provided the working point is
far from the lowpart of the magnetic curve.
100/5 A 5 VA 100/5 A 5 VA
100/5 A 10 VA
Fig. 1
Fig. 2
P1 P2
S1S2
-
Curr
ent
tran
sfor
mer
s. M
easu
ring
and
pro
tect
ion
M.7 / 8
Esto lo conseguimos cuando el transformador midacorrientes
elevadas o cuando el transformador es deprimario bobinado.
El primario del transformador puede ser pasante(una espira de
primario) o bobinado (n espiras deprimario), pero siempre se ha de
cumplir que:
Ns / Np = Ip / IsSiendo Np, N espiras de primario y Ns, N
espiras
de secundario, Ip corriente deprimario y Is corriente
desecundario.
El producto de Ip Np defineel nmero de amperios-vuelta alos que
est trabajando eltransformador. Este nmero deamperios-vuelta es
directamenteproporcional a la potencia y a laclase de precisin
deltransformador. Los amperios-vuelta los podemos aumentarsubiendo
la Ip o aumentando elNp.
Si queremos medir corrientesbajas y necesitamos que
eltransformador suministrepotencia elevadas con clasesde precisin
bajas,necesitaremos aumentar Np, esdecir, transformadores
deprimario bobinado. (tipos TA210,TM45).
NOTA APLICACIN:
Podemos fabricarnos nuestro propio transformadorprimario
bobinado, para la relacin que nos interese,a partir de un
transformador barra pasante,manteniendo las caractersticas de este,
bobinando eltransformador (primario) exteriormente (dibujo).
El transformador as obtenido es equivalente enpotencia y clase
de precisin al barra pasante original,pero con la relacin igual al
Ipn (del barra pasante)dividido por el nmero de espiras aplicadas
alprimario. (deberemos tener en cuenta respetar lapolaridad).
Un transformador TA 30, 300/5 (barra pasante) con2 espiras de
primario lo convertiremos en un TA 30150/5 pero con la potencia y
clase del TA 30, 300/5 A
Barra pasante / Passing bar
Primario bobinado / Wound primary
This situation will arise when the transformer ismeasuring high
currents or when the transformer is ofwound primary type.
The transformer primary can be passing type(primary formed by
one winding) or wound type(primary formed by several windings) but,
at any case,the following formula must be met:
Ns / Np = Ip / IsWhere Np = No. of primary
windings and Ns = No. ofprimary windings; Ip = currentprimary
and Is = secondarycurrent.
The product Ip Np definesthe amps-turns ratio of thetransformer.
This ratio isdirectly proportional to therated output and the
accuracyclass; and can be increasedjust raising Ip or Np value.
In case that we require tomeasure low currents butkeeping a
considerable ratedoutput at a low accuracyclass, Np should be
thenincreased, that is, the use ofwound primary transformerwill be
necessary. (typesTA210, TM45).
APPLICATION NOTE:
A wound primary transformer can be obtained froma passing bar
transformer, keeping also its features,just externally winding the
transformer (see drawing).
The obtained transformer has a rated output andaccuracy class
equivalent to the original passing typebut with a transformation
ratio equal to the division ofthe Ipn value of the passing type
transformer and thenumber of windings done at the primary
side(polarities must always be respected).
For instance, a transformer type TA 30, 300/5(passing bar) with
2 primary windings will become intoa TA 30, 150/5 but delivering
the rated output andaccuracy class of the TA 30, 300/5 A
P1
Ip S1
P2
S2
P1
Ip
S1
P2
S2IB
-
M.7 / 9
Tran
sfor
mad
ores
de
corr
ient
e. M
edid
a y
prot
ecci
n3- Transformadores de barra pasante paramedida de corriente
desde 1 mA
En el punto anterior hemos visto como, debido a lacaractersticas
magnticas de los ncleos utilizadosFe-Si, tenemos unas limitaciones:
linealidad ydimensiones (limitacin del interior en eltransformador
para corrientes bajas).
Para aplicaciones en las que necesitemos medircorrientes bajas
con elevada linealidad y precisin(alta permeabilidad)o cuando el
dimetro de loscables a medir son elevados, aunque la corriente
amedir sea baja (aplicaciones de media alta tensin),utilizaremos
ncleos magnticos de material Fe-Ni.
Estos materiales tienen la caracterstica de elevadalinealidad en
toda su curva magntica y bajainduccin (1-1,1 T) (capacidad de
entregar bajaspotencias), con la caracterstica aadida de unarpida
saturacin.
Aplicaciones:
- Medida de corrientes de fuga (transformadores WG). Esta
aplicacin necesita medir corrientes bajas (p.e 30 mA) con elevadas
ventanas de primario (ver esquema de apliacin). Estos
transformadores estn disponibles hasta 210 mm de ventana
interior
- Medida de potencia (vatmetros, analizadores de redes, en
general) en lneas de bajo nivel de corriente
- Utilizar transformadores ya instalados para la medida de los
parmetros elctricos de la lnea. Para ello conectaremos los
instrumentos en el secundario .../5 mediante un transformador barra
pasante (modelo WG). Este transformador hace las funciones de
separador, aunque su relacin no es 5/5 A
Estos transformadores se calibran con elinstrumento de medida
(DH96, convertidor,CVM-ITFEXT).
3- Passing bar transformers for measuringof currents from 1
mA
At the former section we have seen that due to themagnetic
characteristics of Fe-Si cores, somelimitations of linearity and
dimensions might appear(limitation of the inner diameter for low
currents).
For such applications with the need of measuring alow current
with high linearity and accuracy (highpermeability) or when the
diameter of the carryingcables is high although the current to be
monitored islow (applications at high-voltage), the use of
Fe-Nimagnetic cores will be then required.
This material presents a high linearity at any point ofthe
magnetic curve and also a low induction (1-1.1 T)(ability to supply
low burdens), with the addition of aquick saturation.
Applications:
- Measurement of residual (earth leakage) currents (WG type
transformer). Monitoring residual currents implies to measure very
low currents (ex. 30 mA) with high primary windows (see the
application scheme. These type of transformers are available with
an inner window up to 210 mm
- Measurement of power (wattmeter, digital power meters and
portable network analyzers) at power lines carrying low
currents
- Use of transformers already installed in the facility to
measure the electrical parameters. For this application the
measuring instrument will be connected to the secondary side.../5
of the already existing transformer through an intermediate passing
bar transformer (WG type). These transformers act as a separator
element although its transformation ratio is not 5/5 A, thus, these
must be jointly calibrated with the associated measuring instrument
(DH96, transducer, CVM- ITF-EXT)
4- Using low-voltage current transformersfor measuring at
high-voltage powersystems
Transformers of models TA, TP, WG, TRM or TRPare low-voltage
current transformers, that is, adequatefor power systems with a
maximum service voltage of720 V a.c.
At high-voltage power lines where the insulation isguaranteed by
the own primary cable, the use of low-voltage current transformers
of passing bar type canbe contemplated always noticing that the
features ofthe transformer will always be those for
low-voltagetransformers.
4- Utilizacin de transformadores decorriente, baja tensin, para
medir en lneasde media-alta tensin
Los transformares modelos TA, TP, WG, TRM oTRP son
transformadores para baja tensin, es decir,para ser aplicados en
lneas de v red mxima720 V c.a.
En lneas de media alta tensin, donde elaislamiento quede
garantizado por el mismo cable deprimario, podremos utilizar los
transformadores decorriente en baja tensin, barra pasante, teniendo
encuenta que las caractersticas del transformadorseguiran siendo de
baja tensin.
-
Curr
ent
tran
sfor
mer
s. M
easu
ring
and
pro
tect
ion
M.7 / 10
LA POTENCIA EN UNTRANSFORMADOR
Es un parmetro importante. En el transformador, lacorriente de
primario tiene que inducir en elsecundario la potencia necesaria
para poder transmitirla corriente de secundario al equipo de
medida. Lapotencia inducida tiene que ser igual o superior a
lasperdidas en la lnea ms la del propio consumo delequipo de
medida.
Prdidas en la lnea, PL :Es la potencia perdida por calentamiento
debido al
paso de la corriente por la resistencia RL de cableadodel
circuito de secundario del transformador.
Factores a tener en cuenta: Corriente de secundario. PL = RL I 2
Dimetro cable. RL es inversamente proporcional al
cuadrado del dimetro Longitud cable. RL es proporcional a la
longitud de
cableado (ida + retorno)
Potencia de precisin:La potencia nominal aparente (VA) con un
factor de
potencia especificado, que el transformador decorriente
suministra al circuito secundario con laintensidad asignada cuando
est conectado a sucarga nominal, Sc(VA) = Zc (I
sn)2
Segn normativa, para la potencia aparente mayoro igual a 5 VA,
el factor de potencia es de 0,8inductivo. Para potencias aparentes
ms pequeas elfactor de potencia es la unidad.
Ejemplo: Tenemos un trafo decorriente .../5 A que tiene en
elsecundario un Ampermetro a 10 m.
Datos:LCABLE = 2 l = 2 10 = 20 mSCABLE = 1 mm2RLINEA = 0.017241
20 / 1 = 0.35 PLINEA = 0.35 52 = 8.62 VA- Si fuera un .../1 APLINEA
= 0.35 12 = 0.35 VA, 25 veces
menos
RL = p LS
p = 0,017241 mm2
m
Material del cable: cobreCable material: copper
Impedancia de lineaLine impedance
Ip P1 P2
S1 S2
IsRL
THE TRANSFORMER RATEDOUTPUT
This is an essential parameter; the carried primarycurrent must
induce into the secondary side thenecessary power to transmit the
secondary current tothe measuring instrument, thus, the induced
powermust be equal or higher than the total losses in thecarrying
secondary line plus the own burden of themeasuring instrument.
Losses in the carrying secondary line, PL :The power loss due to
heating provoked by a current
flowing through the resistance RL of the transformersecondary
output circuit.
Factors to consider: Secondary current. PL = RL x I 2 Diameter
of the cable. RL is inversely proportional
to the diameter square Length of the cable. RL is proportional
to the wiring
length (going and back way)
Rated output:The value of the apparent power (VA) at a
specified
power factor which the transformer is intended tosupply to the
secondary circuit at the rated secondarycurrent and with the rated
burden connected to it,Sc (VA) = Zc x (I
sn) 2
According to standards, for an apparent power equalor higher
than 5 VA, the power factor is 0,8 lagged.For lower apparent
powers, the power factor is set at1.
Example: Supposing a .../5 A currenttransformer with an ammeter
connectedto its secondary at a distance of 10 m.
Data:LCABLE = 2 x l = 2 x 10 = 20 mSCABLE = 1 mm 2RLINE =
0.017241 x 20 / 1 = 0.35 PLINE = 0.35 5 2 = 8.62 VA- In case of
.../1 APLINE = 0.35 x 12 = 0.35 VA, 25 times
lower
INSTALACININSTALLATION
TRAFOTRANSFOR.
L = 2 l l (m)
-
M.7 / 11
Tran
sfor
mad
ores
de
corr
ient
e. M
edid
a y
prot
ecci
n
Nota: Con transformadores .../1 A las prdidas se reducen 25
veces
Note: With .../1 A transformers the losses are reduced 25
times
Tabla de prdidas en la lnea del secundario Table of losses in
the secondary line
Longitud de la lnea del secundario Length of the secondary
line
Aparatos DevicesConsumos tpicosTypical burdens
Instrumentos de hierro mvilInstrumentos de bobina mvilVatmetros
analgicosIndicadores de mxima demandaInstrumentos
digitalesContadores de energaInstrumentos registradoresAnalizadores
serie ARAnalizadores serie CHECK-LINEAnalizadores serie
CVMAnalizadores serie ROYALTransformador adaptador TETransformador
sumador TSRRel de corriente WIRel de armnicos WDHRel de corriente
reactiva DIR-1Reguladores de energa reactiva (series MC, MD, y
computer)
Moving iron instrumentsMoving coil instrumentsAnalog
wattmetersMaximum demand indicatorsDigital instrumentsEnergy
metersRecorder instrumentsAR series analyzersCHECK-LINE series
analyzersCVM series analyzersROYAL series analyzersAdapter
transformer TEAdder transformer TSRCurrent relay WIHarmonic relay
WDHReactive current relay DIR-1Reactive power regulator (MC, MDand
computer series)
0.3 ... 1.5 VA0.5 VA
0.2 ... 2.5 VA2.5 ... 5.0 VA0.5 ... 1.0 VA1.0 ... 1.5 VA2.0 ...
5.0 VA
1.25 VA0.7 ... 1.0 VA
0.6 VA0.25 VA2.5 VA2.5 VA1.5 VA2.5 VA0.5 VA0.5 VA
TABLA / TABLE
-
Curr
ent
tran
sfor
mer
s. M
easu
ring
and
pro
tect
ion
M.7 / 12
LA PRECISIN EN UNTRANSFORMADOR
El tipo de error producido en el transformador,establecido por
la I.E.C. 44-1. En los transformadoresde medida para el 25 % y 100
% de la potencianominal. En los de proteccin, slo al 100 % de
lapotencia nominal.
TipoType
% Error para % In
% error for % In
Desfase para % In
Phase displacement for % In
5 20 100 120Minutos / Minutes
5 20 100 120Centiradianes / Centiradians
5 20 100 120
0,10,20,51,0
0,400,751,503,00
0,200,350,751,50
0,100,200,501,00
0,100,200,501,00
153090
180
8154590
5103060
5103060
0,450,92,75,4
0,240,451,352,70
0,150,300,901,80
0,150,300,901,80
Lmites del error. Tabla 1. Clases de precisin / Limits of error.
Table 1. Accuracy class
TipoType
% Error para % In
% of error for % In
Desfase para % In
Phase displacement for % In
1 5 20 100Minutos / Minutes
1 5 20 100Centiradianes / Centiradians
1 5 20 100
0,2S0,5S
0,751,50
0,350,75
0,200,50
0,200,50
3090
1545
1030
1030
1030
0,902,70
0,451,35
0,300,90
120 120 120
0,200,50
0,300,90
0,300,90
Lmites del error. Tabla 2. Clases de precisin / Limits of error.
Table 2. Accuracy class
Lmites del error. Tabla 3. Clases de precisin / Limits of error.
Table 3. Accuracy class
Clase de precisinAccuracy class
% Error para % In
% of error for % In
% In 50 120
35
35
35
No existe error de fase No limits of phase
Para transformadores de proteccin: For protective
transformers:
TipoType
% Error para % In
% of error for % In Minutos / Minutes
5P10P
60---
13
Desfase para In
Phase displacement for In Error compuesto
Composite errorCentiradianesCentiradians
1,8---
510
THE TRANSFORMER ACCURACY
The type of error introduced by the transformer, asper IEC 44-1.
For measuring transformer at the 25 %and 100 % of the rated output.
For protectivetransformers only at the 100 % of the rated
output.
-
M.7 / 13
Tran
sfor
mad
ores
de
corr
ient
e. M
edid
a y
prot
ecci
nEL TRANSFORMADOR FRENTE ALA SATURACIN
Un transformador de corriente est saturado cuandosu corriente de
primario o su carga estn por encimade sus valores nominales.
La linealidad de la transformacin de corriente entreprimario y
secundario disminuye, de forma que elerror es elevado. Se puede
observar como lasaturacin del transformador es
inversamenteproporcional a la carga. (Fig 6)
La diferencia entre los transformadores de corrientepara medida
y proteccin es el comportamiento frentea la sobrecorriente que se
puede producir en elprimario.
Los que se aplican en medida, a partir de unasobrecorriente se
saturan para no daar al equipo delsecundario. En proteccin, no se
saturan hasta unaelevada corriente.
Un transformador de proteccin de clase 5P15indica que no se
satura hasta que pase por elprimario 15 veces la corriente
nominal.
En los transformadores para medida el parmetro deFACTOR DE
SEGURIDAD, Fs nos indica el nmerode veces de corriente primaria que
el transformadores capaz de transferir a los equipos de medida.
FIG. 6
A: Zona de corriente nominal Rated current zoneB: Zona de
sobrecorriente para
transformadores de proteccin Overcurrent zone for protection
transformersC: Zona de sobrecorriente mx. para
transformadores de medida FS < 5 Max. overcurrent zone for
measuring
transformers FS < 5
A
B
C
%
01
3
Erro
r de
corr
ient
e / C
urre
nt e
rro
r
CURVAS DE CLASECLASS CURVES
1,2 5 x Ipn
0,5 10P5 5P5Transformador de medida
Measuring transformerTransformador de medida
Measuring transformer
TRP
A current transformer is saturated when the primarycurrent or
the secondary burden exceed rated values.
The linearity of the current transformation betweenprimary and
secondary sides drops, so, the error ishigh. You can observe that
the transformer saturationis inversely proportional to the burden.
(Fig. 6)
The difference between measuring and protectivetransformer is
the behaviour in the presence of anovercurrent event at the primary
side.
Measuring transformers get saturated when a certainlevel of
primary current is reached in order to notdamage the associated
measuring instrument.Protective transformers only get saturated
when avery high primary current is reached.
A protective transformer of 5P15 class indicates thatthis is not
saturated until a current 15 times higherthan the rated primary
current is flowing through theprimary winding.
For measuring transformers, the parameter calledSECURITY FACTOR
(Fs) sets the number of timesof the primary current that the
transformer is able totransfer to the measuring instrument.
THE TRANSFORMER AGAINSTSATURATION
-
Curr
ent
tran
sfor
mer
s. M
easu
ring
and
pro
tect
ion
M.7 / 14
75/5
100/5
150/5
200/5
300/5
400/5
800/5
1000/5
3000/5
TM 45
2 26 9015/5
25/5
5/5
20/5
15/5
10/5
30/5
40/5
50/5
60/5
125/5
250/5
500/5
600/5
700/5
1500/5
2000/5
2500/5
4000/5
5000/5
2 26 90210/5
2 26 90315/5
2 26 90420/5
2 26 90525/5
2 26 90630/5
2 26 90740/5
. . .
. . .
. . .
. . .
. . .
. . .
100 x 20mm
750/5800/5
1000/5*1200/5*
TA 400
1500/5*
2000/5*
100 x 30mm
2 26 6011500/5
2 26 6022000/5
TA 500
2 26 6032500/5
2 26 6043000/5
2 26 6054000/5
120 x 60mm
2 26 6501000/5
2 26 6511500/5
TA 600
2 26 6522000/5
2 26 6532500/5
2 26 6554000/5
2 26 6543000/5
2 26 6565000/5
400/5
500/5
600/5
750/5800/5
TA 250*TA 300*TA 380*
1000/51200/51500/5
2000/5
2 26 90850/5
TW 25 M
2 26 980100/5
2 26 980125/5
2 26 980150/5
2 26 980200/5
2 26 980250/5
2 26 980300/5
25 mm
TW 25
2 26 983100/5
2 26 984125/5
2 26 985150/5
2 26 986200/5
2 26 987250/5
2 26 988300/5
25 mm
TA 210
2 26 1015/5
2 26 10210/5
2 26 10315/5
2 26 10525/5
2 26 10630/5
2 26 10740/5
2 26 10420/5
2 26 10850/5
2 26 10960/5
2 26 11075/5
2 26 111100/5
2 26 112125/5
2 26 113150/5
2 26 114200/5
2 26 115250/5
2 26 116300/5
2 26 117400/5
TA 20
20 x 5 16 mm
2 26 20140/5
2 26 20250/5
2 26 20360/5
2 26 20475/5
2 26 205100/5
2 26 206125/5
2 26 207150/5
2 26 208200/5
TA 30
30 x 10 22 mm
2 26 251150/5
2 26 252200/5
2 26 253250/5
2 26 254300/5
2 26 255400/5
2 26 256500/5
2 26 257600/5
30 x 10 22 mm
2 26 301100/5
2 26 302125/5
2 26 303150/5
2 26 304200/5
2 26 305250/5
2 26 306300/5
2 26 307400/5
TA 100 B
2 26 308500/5
40 x 10 30 mm
2 26 35150/5
2 26 35260/5
2 26 35375/5
2 26 354100/5
2 26 355125/5
TA 200
2 26 356150/5
2 26 357200/5
2 26 358250/5
2 26 359300/5
2 26 360400/5
2 26 361500/5
2 26 362600/5
2 26 363750/5
2 26 364800/5
2 26 3651000/5
A
30 x 10 22 mm
2 26 41550/5
2 26 41675/5
2 26 417100/5
2 26 419150/5
2 26 418125/5
2 26 420200/5
TA 260
ATA 250 TA 300 TA 380 TA 400
* Tipo y cdigo / Type and code
400/5500/5600/5750/5800/51000/51200/51500/52000/5
2 26 5512 26 5522 26 5532 26 5542 26 5552 26 556
2 26 4012 26 4022 26 4032 26 4042 26 4052 26 4062 26 4072 26
4082 26 40960 x 20 40 mm
2 26 4512 26 4522 26 4532 26 4542 26 4552 26 4562 26 4572 26
4582 26 45980 x 10 50 mm
2 26 5012 26 5022 26 5032 26 5042 26 5052 26 5062 26 5072 26
5082 26 50980 x 30 65 mm
DimensionesDimensions
Tipo y cdigo / Type and code
-
M.7 / 15
Tran
sfor
mad
ores
de
corr
ient
e. M
edid
a y
prot
ecci
nTRANSFORMADORES DECORRIENTE EN RAIL DIN
Sistema de fijacin: acoplable a perfil simtrico DIN 46 277 (EN
50 022)
Bornes de primario: permiten cables de hasta 16 mm2 de
seccin
DIN RAIL MOUNTING CURRENTTRANSFORMERS
Fixing on a symmetrical DIN 46 277 (EN 50 022) rail
Primary connection terminals: wire cross-section up to 16
mm2
Bajo demanda, otros valores / Other values on request
PRIMARIO BOBINADO / WOUND PRIMARY
Bajo demanda, otros valores / Other values on request
BARRA PASANTE / PASSING BAR
* Multi-ratio transformer: The same transformerhave the 6 first
ratios of the table, choosing one oranother ratio depending on the
secondary terminalsconnection.
* Transformador multi-relacin: Agrupa en unnico transformador
las 6 primeras corrientes de latabla anterior, pudiendo escoger una
o otra relacinsegn la conexin de los bornes del secundario.
WIRE: 25 mm CABLE: 25 mm
ACdigo y tipoCode and type
PesoWeight
kg
Potencia / Burden VA
0.5 1 3Clase / Class:
5/510/515/520/525/530/540/550/5
2 26 901 TM 452 26 902 TM 452 26 903 TM 452 26 904 TM 452 26 905
TM 452 26 906 TM 452 26 907 TM 452 26 908 TM 45
55555555
77777777
0.280.280.280.280.280.280.280.28
2.52.52.52.52.52.52.52.5
ACdigo y tipoCode and type
PesoWeight
kg
Potencia / Burden VA
0.5 1 3Clase / Class:
0.340.340.340.340.340.34
0.300.310.310.310.310.31
100/5125/5150/5200/5250/5300/5
100/5125/5150/5200/5250/5300/5
1.5235911
1.5235911
34581113
34581113
--
--
--
346
--
--
--
346
2 26 980 TW 25 M*
2 26 983 TW 252 26 984 TW 252 26 985 TW 252 26 986 TW 252 26 987
TW 252 26 988 TW 25
-
Curr
ent
tran
sfor
mer
s. M
easu
ring
and
pro
tect
ion
M.7 / 16
TRANSFORMADORES DECORRIENTE
CURRENT TRANSFORMERS
Bajo demanda, otros valores / Other values on request
PRIMARIO BOBINADO / WOUND PRIMARY
Tapabornes precintable y base de anclaje incluida Sealable
terminal cover and fixing base included
ACdigo y tipoCode and type
PesoWeight
kg
Potencia / Burden VA
0.5 1 3Clase / Class:
5/510/515/520/525/530/540/550/560/575/5100/5125/5150/5200/5250/5300/5400/5
2 26 101 TA 2102 26 102 TA 2102 26 103 TA 2102 26 104 TA 2102 26
105 TA 2102 26 106 TA 2102 26 107 TA 2102 26 108 TA 2102 26 109 TA
2102 26 110 TA 2102 26 111 TA 2102 26 112 TA 2102 26 113 TA 2102 26
114 TA 2102 26 115 TA 2102 26 116 TA 2102 26 117 TA 210
2020202020202020202020202020202020
3030303030303030303030303030303030
0.700.700.700.700.700.700.700.800.800.750.700.700.700.950.950.800.80
1515151515151515151515151515151515
-
M.7 / 17
Tran
sfor
mad
ores
de
corr
ient
e. M
edid
a y
prot
ecci
nTA 30, TA 30: Sujeta-pletinas y base de anclaje incluidas /
Fixing bus bar device and fixing base includedTA 100B: Tapabornes
precintable, base de anclaje y sujetapletinas incluidas Sealable
terminal cover, fixing base and device for retaining the bar
included
BARRA PASANTE / PASSING BAR
Bajo demanda, otros valores / Other values on request
PLET
INA
/ BU
S BA
R: 2
0 x
5 m
mCA
BLE:
16
mm
PLET
INA
/ BU
S BA
R: 3
0 x
10 m
mCA
BLE:
22
mm
PesoWeight
kgA
Cdigo y tipoCode and type
Potencia / Burden VA
0.5 1 3Clase / Class:
40/550/560/575/5100/5125/5150/5200/5
150/5200/5250/5300/5400/5500/5600/5
100/5125/5150/5200/5250/5300/5400/5500/5
2 26 201 TA 202 26 202 TA 202 26 203 TA 202 26 204 TA 202 26 205
TA 202 26 206 TA 202 26 207 TA 202 26 208 TA 20
2 26 251 TA 302 26 252 TA 302 26 253 TA 302 26 254 TA 302 26 255
TA 302 26 256 TA 302 26 257 TA 30
2 26 301 TA 100B2 26 302 TA 100B2 26 303 TA 100B2 26 304 TA
100B2 26 305 TA 100B2 26 306 TA 100B2 26 307 TA 100B2 26 308 TA
100B
--
--
1,251,252,53,7555
1,752,52,533,7555
57,5101520203050
1,252,52,52,53,7557,57,5
2,53,753,75457,57,5
1010152530305065
0,250,250,250,260,250,260,260,28
0,150,150,150,150,170,180,20
0.650.680.700.700.680.540.560.60
--
--
--
--
--
1,251,252,5
--
--
1,252,52,53,753,75
2551010101520
-
Curr
ent
tran
sfor
mer
s. M
easu
ring
and
pro
tect
ion
M.7 / 18
Bajo demanda, otros valores / Other values on request
BARRA PASANTE / PASSING BAR PL
ETIN
A /
BUS
BAR:
40
x 10
mm
CABL
E:
30
mm
PL
ETIN
A /
BUS
BAR:
60
x 20
mm
CABL
E:
40
mm
ACdigo y tipoCode and type
PesoWeight
kg
Potencia / Burden VA
0.5 1 3Clase / Class:
50/560/575/5100/5125/5150/5200/5250/5300/5400/5500/5600/5750/5800/51000/5
400/5500/5600/5750/5800/51000/51200/51500/52000/5
50/575/5100/5125/5150/5200/5
2 26 351 TA 2002 26 352 TA 2002 26 353 TA 2002 26 354 TA 2002 26
355 TA 2002 26 356 TA 2002 26 357 TA 2002 26 358 TA 2002 26 359 TA
2002 26 360 TA 2002 26 361 TA 2002 26 362 TA 2002 26 363 TA 2002 26
364 TA 2002 26 365 TA 200
2 26 401 TA 2502 26 402 TA 2502 26 403 TA 2502 26 404 TA 2502 26
405 TA 2502 26 406 TA 2502 26 407 TA 2502 26 408 TA 2502 26 409 TA
250
2 26 415 TA 2602 26 416 TA 2602 26 417 TA 2602 26 418 TA 2602 26
419 TA 2602 26 420 TA 260
--
--
1,5333557,57,51015151520
202020202020202020
246101515
--
--
--
--
--
--
2,53,755557,5101015
101515151515151515
--
--
--
61010
PL
ETIN
A /
BUS
BAR:
30
x 10
mm
CABL
E:
22
mm
0,450,450,480,480,500,360,360,380,380,400,400,400,410,410,45
0,720,720,720,550,550,400,400,450,50
1,211,231,241,261,271,30
Tapabornes precintable , base de anclaje y sujetapletinas
incluida Sealable terminal cover, fixing base and device for
retaining the bar included
1,51,52,555577,510101520252530
303030303030303030
57,510152020
-
M.7 / 19
Tran
sfor
mad
ores
de
corr
ient
e. M
edid
a y
prot
ecci
n
Bajo demanda, otros valores / Other values on request
BARRA PASANTE / PASSING BAR
Tapabornes precintable , base de anclaje y sujetapletinas
incluida Sealable terminal cover, fixing base and device for
retaining the bar included
PL
ETIN
A /
BUS
BAR:
80
x 30
mm
CABL
E:
65
mm
PL
ETIN
A /
BUS
BAR:
100
x 2
0 m
m PL
ETIN
A /
BUS
BAR:
80
x 10
mm
CABL
E:
50
mm
ACdigo y tipoCode and type
PesoWeight
kg
Potencia / Burden VA
0.5 1 3Clase / Class:
2 26 451 TA 3002 26 452 TA 3002 26 453 TA 3002 26 454 TA 3002 26
455 TA 3002 26 456 TA 3002 26 457 TA 3002 26 458 TA 3002 26 459 TA
300
101010151515203040
151515202025304050
303030303030405060
0,820,800,830,880,660,720,680,840,82
400/5500/5600/5750/5800/51000/51200/51500/52000/5
2 26 501 TA 3802 26 502 TA 3802 26 503 TA 3802 26 504 TA 3802 26
505 TA 3802 26 506 TA 3802 26 507 TA 3802 26 508 TA 3802 26 509 TA
380
2 26 551 TA 4002 26 552 TA 4002 26 553 TA 4002 26 554 TA 4002 26
555 TA 4002 26 556 TA 400
400/5500/5600/5750/5800/51000/51200/51500/52000/5
750/5800/51000/51200/51500/52000/5
101010151515203040
151515151520
151515202025304050
202020203040
303030303030405060
303030304050
0,820,800,830,880,660,720,680,840,82
0,800,800,760,760,760,76
-
Curr
ent
tran
sfor
mer
s. M
easu
ring
and
pro
tect
ion
M.7 / 20
PIEZA DE ANCLAJE / FIXING BASE
Bajo demanda, otros valores / Other values on request
Tapabornes precintable, base de anclaje y sujetapletinas
incluidaSealable terminal cover, fixing base and fixing bus bar
device included
PL
ETIN
A /
BUS
BAR:
100
x 3
0 m
m PL
ETIN
A /
BUS
BAR:
125
x 6
0 m
m
ACdigo y tipoCode and type
PesoWeight
kg
Potencia / Burden VA
0.5 1 3Clase / Class:
1000/51500/52000/52500/53000/54000/55000/5
20202030405060
30303040607080
0,750,830,921,011,091,211,44
15151520303540
2 26 601 TA 5002 26 602 TA 5002 26 603 TA 5002 26 604 TA 5002 26
605 TA 500
1500/52000/52500/53000/54000/5
3040404550
4050506070
0,760,820,780,900,90
1520202035
BARRA PASANTE / PASSING BAR
CdigoCode
2 99 010
Tipo / Type Peso / Weightkg
0,01PA Piezas para anclaje en RAIL DIN de los transformadores de
las series TA 20 y TA 30PA Fixing base for DIN RAIL mounting of
C.T.s TA 20 and TA 30 series.
2 26 650 TA 6002 26 651 TA 6002 26 652 TA 6002 26 653 TA 6002 26
654 TA 6002 26 655 TA 6002 26 656 TA 600
-
M.7 / 21
Tran
sfor
mad
ores
de
corr
ient
e. M
edid
a y
prot
ecci
nTRANSFORMADORES DECORRIENTE CLASE 0,2S
CURRENT TRANSFORMERS WITHCLASS 0,2S
Tipo y cdigo / Type and code
4500/5
5000/5
A
3500/5
4000/5
. . .
3000/5
2500/5
2000/5
1500/5
1400/5
1300/5
1200/5
1100/5
1000/5
900/5
800/5
700/5
600/5
500/5
400/5
300/5
. . .
250/5
200/5
150/5
100/5
40 x 10 30 mm
TAS 200
2 25 701200/5
2 25 702300/5
2 25 703400/5
2 25 704500/5
2 25 705600/5
2 25 706750/5
2 25 7071000/5
60 x 20 40 mm
TAS 250
2 25 721400/5
2 25 722500/5
2 25 723600/5
2 25 724750/5
2 25 7251000/5
2 25 7261500/5
2 25 7272000/5
30 x 10 22 mm
TAS 260
2 25 731100/5
2 25 732125/5
2 25 733150/5
2 25 734200/5
80 x 10 50 mm
TAS 300
2 25 741400/5
2 25 742500/5
2 25 743600/5
2 25 744750/5
2 25 7451000/5
2 25 7471500/5
2 25 7482000/5
2 25 7461200/5
80 x 30 65 mm
TAS 380
2 25 751400/5
2 25 752500/5
2 25 753600/5
2 25 754750/5
2 25 7551000/5
2 25 7571500/5
2 25 7582000/5
2 25 7561200/5
100 x 20
TAS 400
2 25 7711000/5
2 25 7721200/5
2 25 7731500/5
2 25 7742000/5
100 x 30
TAS 500
2 25 7811500/5
2 25 7832500/5
2 25 7843000/5
2 25 7854000/5
2 25 7822000/5
120 x 60
TAS 600
2 25 7911000/5
2 25 7932000/5
2 25 7953000/5
2 25 7964000/5
2 25 7921500/5
2 25 7942500/5
2 25 7975000/5
-
Curr
ent
tran
sfor
mer
s. M
easu
ring
and
pro
tect
ion
M.7 / 22
Bajo demanda, otros valores / Other values on request
BARRA PASANTE / PASSING BAR PL
ETIN
A /
BUS
BAR:
40
x 10
mm
CABL
E:
30
mm
PL
ETIN
A /
BUS
BAR:
60
x 20
mm
CABL
E:
40
mm
ACdigo y tipoCode and type
PesoWeight
kg
PotenciaBurden VA
ClaseClass
200/5300/5400/5500/5600/5750/51000/5... / 1
400/5500/5600/5750/51000/51500/52000/5... / 1
100/5125/5150/5200/5... / 1
2 25 701 TAS 2002 25 702 TAS 2002 25 703 TAS 2002 25 704 TAS
2002 25 705 TAS 2002 25 706 TAS 2002 25 707 TAS 2002 25 710 TAS
200
2 25 721 TAS 2502 25 722 TAS 2502 25 723 TAS 2502 25 724 TAS
2502 25 725 TAS 2502 25 726 TAS 2502 25 727 TAS 2502 25 730 TAS
250
2 25 731 TAS 2602 25 732 TAS 2602 25 733 TAS 2602 25 734 TAS
2602 25 740 TAS 260
1,251,501,5022,502,754---
1,5022,504556---
1,251,502,504---
PL
ETIN
A /
BUS
BAR:
30
x 10
mm
CABL
E:
22
mm
Tapabornes precintable , base de anclaje y sujetapletinas
incluida Sealable terminal cover, fixing base and device for
retaining the bar included
0,2S
0,2S
0,2S
0,360,380,400,400,400,410,45---
0,720,720,720,550,400,450,50---
1,241,261,271,30---
-
M.7 / 23
Tran
sfor
mad
ores
de
corr
ient
e. M
edid
a y
prot
ecci
n
Bajo demanda, otros valores / Other values on request
BARRA PASANTE / PASSING BAR
Tapabornes precintable , base de anclaje y sujetapletinas
incluida Sealable terminal cover, fixing base and device for
retaining the bar included
PL
ETIN
A /
BUS
BAR:
80
x 30
mm
CABL
E:
65
mm
PL
ETIN
A /
BUS
BAR:
100
x 2
0 m
m PL
ETIN
A /
BUS
BAR:
80
x 10
mm
CABL
E:
50
mm
ACdigo y tipoCode and type
PesoWeight
kg
PotenciaBurden VA
ClaseClass
2 25 741 TAS 3002 25 742 TAS 3002 25 743 TAS 3002 25 744 TAS
3002 25 745 TAS 3002 25 746 TAS 3002 25 747 TAS 3002 25 748 TAS
3002 25 750 TAS 300
2,503,50461012,501515---
0,2S
400/5500/5600/5750/51000/51200/51500/52000/5... / 1
400/5500/5600/5750/51000/51200/51500/52000/5... / 1
1000/51200/51500/52000/5... / 1
2,503,50461012,501515---
1,5041010---
0,2S
0,2S
0,820,800,830,880,720,680,840,82---
2 25 751 TAS 3802 25 752 TAS 3802 25 753 TAS 3802 25 754 TAS
3802 25 755 TAS 3802 25 756 TAS 3802 25 757 TAS 3802 25 758 TAS
3802 25 759 TAS 380
2 25 771 TAS 4002 25 772 TAS 4002 25 773 TAS 4002 25 774 TAS
4002 25 780 TAS 400
0,820,800,830,880,720,680,840,82---
0,760,760,760,76---
-
Curr
ent
tran
sfor
mer
s. M
easu
ring
and
pro
tect
ion
M.7 / 24
Bajo demanda, otros valores / Other values on request
Tapabornes precintable, base de anclaje y sujetapletinas
incluidaSealable terminal cover, fixing base and fixing bus bar
device included
PL
ETIN
A /
BUS
BAR:
100
x 3
0 m
m PL
ETIN
A /
BUS
BAR:
125
x 6
0 m
m
ACdigo y tipoCode and type
PesoWeight
kg
PotenciaBurden VA
ClaseClass
2 25 781 TAS 5002 25 782 TAS 5002 25 783 TAS 5002 25 784 TAS
5002 25 785 TAS 5002 25 790 TAS 500
1500/52000/52500/53000/54000/5... / 1
1010101010---
0,2S
BARRA PASANTE / PASSING BAR
0,760,820,780,900,90---
2 25 791 TAS 6002 25 792 TAS 6002 25 793 TAS 6002 25 794 TAS
6002 25 795 TAS 6002 25 796 TAS 6002 25 797 TAS 6002 25 799 TAS
600
1000/51500/52000/52500/53000/54000/55000/5... / 1
1,507,501010101010---
0,2S
0,750,830,921,011,091,211,44---
-
M.7 / 25
Tran
sfor
mad
ores
de
corr
ient
e. M
edid
a y
prot
ecci
nTRANSFORMADORES DECORRIENTE CLASE 0,2
CURRENT TRANSFORMERS WITHCLASS 0,2
Tipo y cdigo / Type and code
4500/5
5000/5
A
3500/5
4000/5
. . .
3000/5
2500/5
2000/5
1500/5
1400/5
1300/5
1200/5
1100/5
1000/5
900/5
800/5
700/5
600/5
500/5
400/5
300/5
. . .
250/5
200/5
150/5
100/5
40 x 10 30 mm
TAB 200
2 25 803400/5
2 25 804500/5
2 25 805600/5
2 25 806750/5
2 25 8071000/5
60 x 20 40 mm
TAB 250
2 25 822500/5
2 25 823600/5
2 25 824750/5
2 25 8251000/5
2 25 8261500/5
2 25 8272000/5
30 x 10 22 mm
TAB 260
2 25 833150/5
2 25 834200/5
80 x 10 50 mm
TAB 300
2 25 842500/5
2 25 843600/5
2 25 844750/5
2 25 8451000/5
2 25 8471500/5
2 25 8482000/5
2 25 8461200/5
80 x 30 65 mm
TAB 380
2 25 852500/5
2 25 853600/5
2 25 854750/5
2 25 8551000/5
2 25 8571500/5
2 25 8582000/5
2 25 8561200/5
100 x 20
TAB 400
2 25 8711000/5
2 25 8721200/5
2 25 8731500/5
2 25 8742000/5
100 x 30
TAB 500
2 25 8811500/5
2 25 8832500/5
2 25 8843000/5
2 25 8854000/5
2 25 8822000/5
120 x 60
TAB 600
2 25 8911000/5
2 25 8932000/5
2 25 8953000/5
2 25 8964000/5
2 25 8921500/5
2 25 8942500/5
2 25 8975000/5
-
Curr
ent
tran
sfor
mer
s. M
easu
ring
and
pro
tect
ion
M.7 / 26
Bajo demanda, otros valores / Other values on request
BARRA PASANTE / PASSING BAR PL
ETIN
A /
BUS
BAR:
40
x 10
mm
CABL
E:
30
mm
PL
ETIN
A /
BUS
BAR:
60
x 20
mm
CABL
E:
40
mm
ACdigo y tipoCode and type
PesoWeight
kg
PotenciaBurden VA
ClaseClass
400/5500/5600/5750/51000/5... / 1
500/5600/5750/51000/51500/52000/5... / 1
150/5200/5... / 1
2 25 803 TAB 2002 25 804 TAB 2002 25 805 TAB 2002 25 806 TAB
2002 25 807 TAB 2002 25 810 TAB 200
2 25 822 TAB 2502 25 823 TAB 2502 25 824 TAB 2502 25 825 TAB
2502 25 826 TAB 2502 25 827 TAB 2502 25 830 TAB 250
2 25 833 TAB 2602 25 834 TAB 2602 25 840 TAB 260
1,2523510---
233,506,501010---
1,252,50---
PL
ETIN
A /
BUS
BAR:
30
x 10
mm
CABL
E:
22
mm
Tapabornes precintable , base de anclaje y sujetapletinas
incluida Sealable terminal cover, fixing base and device for
retaining the bar included
0,2
0,2
0,2
0,400,400,400,410,45---
0,720,720,550,400,450,50---
1,271,30---
-
M.7 / 27
Tran
sfor
mad
ores
de
corr
ient
e. M
edid
a y
prot
ecci
n
Bajo demanda, otros valores / Other values on request
BARRA PASANTE / PASSING BAR
Tapabornes precintable , base de anclaje y sujetapletinas
incluida Sealable terminal cover, fixing base and device for
retaining the bar included
PL
ETIN
A /
BUS
BAR:
80
x 30
mm
CABL
E:
65
mm
PL
ETIN
A /
BUS
BAR:
100
x 2
0 m
m PL
ETIN
A /
BUS
BAR:
80
x 10
mm
CABL
E:
50
mm
ACdigo y tipoCode and type
PesoWeight
kg
PotenciaBurden VA
ClaseClass
2 25 842 TAB 3002 25 843 TAB 3002 25 844 TAB 3002 25 845 TAB
3002 25 846 TAB 3002 25 847 TAB 3002 25 848 TAB 3002 25 850 TAB
300
1,50447,50101515---
0,2
500/5600/5750/51000/51200/51500/52000/5... / 1
500/5600/5750/51000/51200/51500/52000/5... / 1
1000/51200/51500/52000/5... / 1
1,50447,50101515---
5101010---
0,2
0,2
0,800,830,880,720,680,840,82---
2 25 852 TAB 3802 25 853 TAB 3802 25 854 TAB 3802 25 855 TAB
3802 25 856 TAB 3802 25 857 TAB 3802 25 858 TAB 3802 25 859 TAB
380
2 25 871 TAB 4002 25 872 TAB 4002 25 873 TAB 4002 25 874 TAB
4002 25 880 TAB 400
0,800,830,880,720,680,840,82---
0,760,760,760,76---
-
Curr
ent
tran
sfor
mer
s. M
easu
ring
and
pro
tect
ion
M.7 / 28
Bajo demanda, otros valores / Other values on request
Tapabornes precintable, base de anclaje y sujetapletinas
incluidaSealable terminal cover, fixing base and fixing bus bar
device included
PL
ETIN
A /
BUS
BAR:
100
x 3
0 m
m PL
ETIN
A /
BUS
BAR:
125
x 6
0 m
m
ACdigo y tipoCode and type
PesoWeight
kg
PotenciaBurden VA
ClaseClass
2 25 881 TAB 5002 25 882 TAB 5002 25 883 TAB 5002 25 884 TAB
5002 25 885 TAB 5002 25 890 TAB 500
1500/52000/52500/53000/54000/5... / 1
1212121212---
0,2
BARRA PASANTE / PASSING BAR
0,760,820,780,900,90---
2 25 891 TAB 6002 25 892 TAB 6002 25 893 TAB 6002 25 894 TAB
6002 25 895 TAB 6002 25 896 TAB 6002 25 897 TAB 6002 25 899 TAB
600
1000/51500/52000/52500/53000/54000/55000/5... / 1
7,50101212151515---
0,2
0,750,830,921,011,091,211,44---
-
M.7 / 29
Tran
sfor
mad
ores
de
corr
ient
e. M
edid
a y
prot
ecci
nTRANSFORMADORES DECORRIENTE CLASE 0,5S
CURRENT TRANSFORMERS WITHCLASS 0,5S
Tipo y cdigo / Type and code
4500/5
5000/5
A
3500/5
4000/5
. . .
3000/5
2500/5
2000/5
1500/5
1400/5
1300/5
1200/5
1100/5
1000/5
900/5
800/5
700/5
600/5
500/5
400/5
300/5
. . .
250/5
200/5
150/5
100/5
40 x 10 30 mm
TAC 200
2 25 903400/5
2 25 904500/5
2 25 905600/5
2 25 906750/5
2 25 9071000/5
60 x 20 40 mm
TAC 250
2 25 922500/5
2 25 923600/5
2 25 924750/5
2 25 9251000/5
2 25 9261500/5
2 25 9272000/5
30 x 10 22 mm
TAC 260
2 25 932125/5
80 x 10 50 mm
TAC 300
2 25 942500/5
2 25 943600/5
2 25 944750/5
2 25 9451000/5
2 25 9471500/5
2 25 9482000/5
2 25 9461200/5
80 x 30 65 mm
TAC 380
2 25 952500/5
2 25 953600/5
2 25 954750/5
2 25 9551000/5
2 25 9571500/5
2 25 9582000/5
2 25 9561200/5
100 x 20
TAC 400
2 25 9711000/5
2 25 9721200/5
2 25 9731500/5
2 25 9742000/5
100 x 30
TAC 500
2 25 9811500/5
2 25 9832500/5
2 25 9843000/5
2 25 9854000/5
2 25 9822000/5
120 x 60
TAC 600
2 25 9911000/5
2 25 9932000/5
2 25 9953000/5
2 25 9964000/5
2 25 9921500/5
2 25 902300/5
2 25 901200/5
2 25 921400/5
2 25 9942500/5
2 25 9975000/5
-
Curr
ent
tran
sfor
mer
s. M
easu
ring
and
pro
tect
ion
M.7 / 30
Bajo demanda, otros valores / Other values on request
BARRA PASANTE / PASSING BAR PL
ETIN
A /
BUS
BAR:
40
x 10
mm
CABL
E:
30
mm
PL
ETIN
A /
BUS
BAR:
60
x 20
mm
CABL
E:
40
mm
ACdigo y tipoCode and type
PesoWeight
kg
PotenciaBurden VA
ClaseClass
200/5300/5400/5500/5600/5750/51000/5... / 1
400/5500/5600/5750/51000/51500/52000/5... / 1
125/5... / 1
2 25 901 TAC 2002 25 902 TAC 2002 25 903 TAC 2002 25 904 TAC
2002 25 905 TAC 2002 25 906 TAC 2002 25 907 TAC 2002 25 910 TAC
200
2 25 921 TAC 2502 25 922 TAC 2502 25 923 TAC 2502 25 924 TAC
2502 25 925 TAC 2502 25 926 TAC 2502 25 927 TAC 2502 25 930 TAC
250
2 25 932 TAC 2602 25 940 TAC 260
23557,501015---
3,5057,508,501012,515---
0,75---
PL
ETIN
A /
BUS
BAR:
30
x 10
mm
CABL
E:
22
mm
Tapabornes precintable , base de anclaje y sujetapletinas
incluida Sealable terminal cover, fixing base and device for
retaining the bar included
0,5S
0,5S
0,360,380,400,400,400,410,45---
0,720,720,720,550,400,450,50---
1,26---
0,5S
-
M.7 / 31
Tran
sfor
mad
ores
de
corr
ient
e. M
edid
a y
prot
ecci
n
Bajo demanda, otros valores / Other values on request
BARRA PASANTE / PASSING BAR
Tapabornes precintable , base de anclaje y sujetapletinas
incluida Sealable terminal cover, fixing base and device for
retaining the bar included
PL
ETIN
A /
BUS
BAR:
80
x 30
mm
CABL
E:
65
mm
PL
ETIN
A /
BUS
BAR:
100
x 2
0 m
m PL
ETIN
A /
BUS
BAR:
80
x 10
mm
CABL
E:
50
mm
ACdigo y tipoCode and type
PesoWeight
kg
PotenciaBurden VA
ClaseClass
2 25 942 TAC 3002 25 943 TAC 3002 25 944 TAC 3002 25 945 TAC
3002 25 946 TAC 3002 25 947 TAC 3002 25 948 TAC 3002 25 950 TAC
300
57,507,5012,5012,501520---
0,5S
500/5600/5750/51000/51200/51500/52000/5... / 1
500/5600/5750/51000/51200/51500/52000/5... / 1
1000/51200/51500/52000/5... / 1
57,507,5012,5012,501520---
7,5012,5012,5012,50---
0,5S
0,5S
0,800,830,880,720,680,840,82---
2 25 952 TAC 3802 25 953 TAC 3802 25 954 TAC 3802 25 955 TAC
3802 25 956 TAC 3802 25 957 TAC 3802 25 958 TAC 3802 25 959 TAC
380
2 25 971 TAC 4002 25 972 TAC 4002 25 973 TAC 4002 25 974 TAC
4002 25 980 TAC 400
0,800,830,880,720,680,840,82---
0,760,760,760,76---
-
Curr
ent
tran
sfor
mer
s. M
easu
ring
and
pro
tect
ion
M.7 / 32
Bajo demanda, otros valores / Other values on request
Tapabornes precintable, base de anclaje y sujetapletinas
incluidaSealable terminal cover, fixing base and fixing bus bar
device included
PL
ETIN
A /
BUS
BAR:
100
x 3
0 m
m PL
ETIN
A /
BUS
BAR:
125
x 6
0 m
m
ACdigo y tipoCode and type
PesoWeight
kg
PotenciaBurden VA
ClaseClass
2 25 981 TAC 5002 25 982 TAC 5002 25 983 TAC 5002 25 984 TAC
5002 25 985 TAC 5002 25 990 TAC 500
1500/52000/52500/53000/54000/5... / 1
12,5012,5012,5012,5012,50---
0,5S
BARRA PASANTE / PASSING BAR
0,760,820,780,900,90---
2 25 991 TAC 6002 25 992 TAC 6002 25 993 TAC 6002 25 994 TAC
6002 25 995 TAC 6002 25 996 TAC 6002 25 997 TAC 6002 25 999 TAC
600
1000/51500/52000/52500/53000/54000/55000/5... / 1
1012,5012,5012,50152020---
0,5S
0,750,830,921,011,091,211,44---
-
M.7 / 33
Tran
sfor
mad
ores
de
corr
ient
e. M
edid
a y
prot
ecci
nTRANSFORMADORES DECORRIENTE DE
PRIMARIOPASANTEAUTOSOPORTANTES
El circuito primario es pasante y se ajusta altransformador
mediante un prensaestopas adaptablea la seccin del cable, con lo
que el transformadorqueda fijado al conductor. El transformador
nodispone de ningn borne, ya que la salida delsecundario incorpora
un cable de 1.5 m de longitudpara facilitar su instalacin.
The primary passing bar can be adjusted to thecurrent
transformer by means of a cable glandadaptable to the cross
section. This allows adaptingthe transformer to the primary cable.
The transformerdoes not have any terminal because the
secundaryoutput is a 1.5 m length cable in order to ease
theinstallation.
SELF-FIXING PASSING BARCURRENT TRANSFORMERS
ACdigo y tipoCode and type
PesoWeight
kg
Potencia / Burden VA
0.5 1 3Clase / Class:
100/5200/5300/5400/5500/5600/5
2 26 801 WJ 292 26 802 WJ 292 26 803 WJ 292 26 804 WJ 292 26 805
WJ 292 26 806 WJ 29
--
3681010
15791113
0,510,510,510,510,510,51
--
2,544,555
Bajo demanda, otros valores / Other values on request
WJ
DIMENSIONES / DIMENSIONS
-
Curr
ent
tran
sfor
mer
s. M
easu
ring
and
pro
tect
ion
M.7 / 34
Normas
CARACTERSTICAS TCNICAS TECHNICAL CHARACTERISTICS
Standards
TM, TW, TA, WJ
IEC 44-1, UNE 21 088-1, UL 94, VDE 0414
Tensin ms elevadapara el material (U
m)
Nivel de aislamiento asignadoRespuestas en frecuenciasCorriente
trmica decortocircuito asignada (Ith)Corriente dinmica asignada
(Idyn)Relacin de transformacin, potencia de precisin y clase de
precisinFactor de seguridad (FS)Clase trmicaUsoEnvolvente
Caja de bornes del secundario
DimensionesSistema de fijacinPeso
Highest voltage forequipment (U
m)
Rated insulation levelFrequency response
Rated short-timethermal current (Ith)
Rated dynamic current (Idyn)Transformer ratio, rated output
and accuracy classInstrument security factor (FS)
Thermal classUse
Coating
Secondary terminal box
DimensionsFixing system
Weight
0,72 kV c.a. / a.c.
3 kVLineal / Linear 50...60 Hz
60 /n
2,5 IthSegn tipos / Depending on types
(.../5A / or .../1A)< 5A
Interior / IndoorAutoextinguible / Self-extinguishing
( UL94VO)Segn tipo, precintable
Depending on types, sealableSegn tipos / Depending on typesSegn
tipos / Depending on typesSegn tipos / Depending on types
-
M.7 / 35
Tran
sfor
mad
ores
de
corr
ient
e. M
edid
a y
prot
ecci
n
Los transformadores de corriente tipo TP han sidoespecialmente
diseados para facilitar su colocacin,tanto en instalaciones nuevas
como en las yaexistentes. Gracias a su ncleo partido permiten
suinstalacin sin necesidad de interrumpir ningn cableo pletina.
La conexin de los transformadores de corrienteconvencionales
requiere la interrupcin del circuitoprimario para pasar cables o
pletinas por el interior delncleo o para conectarlos a los bornes
del primario.Los transformadores tipo TP permiten la apertura desu
ncleo y por tanto permiten su colocacin sin tenerque interrumpir el
suministro, con el consiguienteahorro de tiempo y coste.
Las caractersticas ms destacables de lostransformadores TP
son:
Pequeo tamao y facilidad de instalacin Amplias dimensiones de la
ventana interior,
permitiendo abrazar cables gruesos o grandes pletinas
Amplia gama de tamaos que permiten adaptarlos a cualquier
instalacin existente
Pieza de conexin para cortocircuitar el secundario durante la
instalacin
Corrientes de primario desde 100 hasta 5000 A Salidas de
secundario 5 A, 1 A 1.5 V Gran precisin y seguridad
SPLIT CORE CURRENTTRANSFORMERSTP Series
The TP series of current transformers have beenespecially
designed to facilitate their installation in newor already existing
networks. Thanks to its split corethey may be installed without
opening any cable orbus bar circuit.
The connection of conventional CTs usually requiresthe
interruption of the primary side circuit to passcables or bus bars
through the transformer core or toconnect such cables to the
primary terminals. The TPseries transformers core may be easily
opened andthey may be installed and connected without anysupply
interruption, thus saving time and installationcosts.
The main features of TP transformers are then: Small size and
easy mounting Wide inner window, allowing clamping of big
cables or bus bars Wide range of sizes to accomodate all the
existing
installations Terminal strip to short circuit the secondary
side
during the installation Primary ranges from 100 to 5000 A
Secondary output 5 A, 1 A or 1.5 V High accuracy and
reliability
PresionarPress
FijarInsert and tighten
TP
TRANSFORMADORES DECORRIENTE, DE NCLEO PARTIDOSerie TP
-
Curr
ent
tran
sfor
mer
s. M
easu
ring
and
pro
tect
ion
M.7 / 36
Bajo demanda se puede suministrar cualquier salida por
tensin
0.5 1 3A
Cdigo y tipoCode and type
Potencia / Burden VAClase / Class:
100/5150/5200/5250/5300/5400/5
250/5300/5400/5500/5600/5700/5800/51000/5
250/5300/5400/5500/5600/5750/5800/51000/5
500/5600/5750/5800/51000/51200/51250/51500/5
1000/51500/52000/52500/53000/54000/55000/5
2 22 005 TP 232 22 006 TP 232 22 007 TP 232 22 008 TP 232 22 009
TP 232 22 010 TP 23
2 22 025 TP 582 22 026 TP 582 22 027 TP 582 22 028 TP 582 22 029
TP 582 22 030 TP 582 22 031 TP 582 22 032 TP 58
2 22 035 TP 882 22 036 TP 882 22 037 TP 882 22 038 TP 882 22 039
TP 882 22 040 TP 882 22 041 TP 882 22 042 TP 88
2 22 048 TP-8122 22 049 TP-8122 22 050 TP-8122 22 051 TP-8122 22
052 TP-8122 22 053 TP-8122 22 054 TP-8122 22 055 TP-812
2 22 061 TP-8162 22 062 TP-8162 22 063 TP-8162 22 064 TP-8162 22
065 TP-8162 22 066 TP-8162 22 067 TP-816
--
--
1,5246
233556710
233556710
45679111517
15202020252525
1,522,54610
46101517,5181820
46101517,5181820
1214171820242830
20252525303030
--
--
--
--
1,52,5
11,51,52,52,5335
11,51,52,52,5335
--
--
2,535678
10151515202020
SERIE TP / TP SERIES
Any voltage output can be supplied on request
TP-58
Centradores de fijacin pletinaDevices for centring the bus-
bar fixing
NOTA: Todos los tipos llevarn centradores de fijacin excepto el
TP-23NOTE: All types will be factory delivered with devices for
centring the bus-bar fixing excepts for the TP-23
ATipoType
PesoWeight
TP-23
TP-58
TP-88
TP-812
TP-816
51
78
108
108
120
89
114
144
144
184
110
145
145
185
245
34
32
32
32
52
47
32
32
32
47
40
32
32
32
52
32
33
33
33
38
0,75 kg
0,90 kg
1,00 kg
1,20 kg
3,50 kg
20
50
80
80
80
30
80
80
120
160
B GFEDC IH
-
M.7 / 37
Tran
sfor
mad
ores
de
corr
ient
e. M
edid
a y
prot
ecci
n
Normas
CARACTERSTICAS TCNICAS TECHNICAL CHARACTERISTICS
Standards
TP
IEC 44-1, UNE 21 088-1, UL 94, VDE 0414
Highest voltage forequipment (U
m)
Rated insulation levelFrequency response
Rated short-timethermal current (Ith)
Rated dynamic current (Idyn)Transformer ratio, rated output
and accuracy classThermal class
UseCoating
Secondary terminal boxDimensions and weight
0,72 kV c.a. / a.c.
3 kVLineal / Linear 50...60 Hz
60 In
2,5 IthSegn tipos / Depending on types
(.../5 A / or .../1 A)A
Interior / IndoorAutoextinguible / Self-extinguishing
(UL94VO)Precintable / Sealable
Segn tipos / Depending on types
Tensin ms elevadapara el material (U
m)
Nivel de aislamiento asignadoRespuesta en frecuenciasCorriente
trmica decortocircuito asignada (Ith)Corriente dinmica asignada
(Idyn)Relacin de transformacin, potencia de precisin y clase de
precisinClase trmicaUsoEnvolvente
Caja de bornes del secundarioDimensiones y peso
-
Curr
ent
tran
sfor
mer
s. M
easu
ring
and
pro
tect
ion
M.7 / 38
TRANSFORMADOR SUMADORDE CORRIENTESerie TSR
Es frecuente, en instalaciones elctricas, el tenerque sumar
corrientes de diferentes lneas paraobtener una medida comn.
ISALIDA =I1 + I2 + ... + In
n
CURRENT ADDINGTRANSFORMERTSR Series
IOUTPUT =I1 + I2 + ... + In
n
It is often necessary to add up the currents ofseparate circuits
to get a response depending on thetotal consumed current.
donde n es el nmero deentradas del sumador y I1, I2, ...,In son
las corrrientes de cada
entrada.Para que puedan sumarse
corrientes procedentes de variostransformadores de corriente
y
come from transformers having the same currentratio.
Current adders for different ratio inputs can besupplied on
request.
Los transformadoressumadores de corriente ofrecenuna fcil
solucin a esteproblema; disponen dediferentes entradas de In/5 A
yuna nica salida de 5 A queequivale a la suma de dichasentradas
(ver fig. 2)
La corriente de salida deltransformador sumador seobtiene del
siguiente clculo:
la salida sea proporcional a los mismos es necesarioque la
relacin de los transformadores sea la misma.
Bajo demanda pueden suministrarsetransformadores sumadores para
entradas que notengan la misma relacin.
For this purpose, the currentadding transformers offer aneasy
solution. These deviceshave several input windings In/5and an
output winding whichgives a value proportional to thesum of the
input currents with afull of 5 A (see fig. 2).
The output current of the addertransformer is obtained bymeans
of the followingexpression:
where n is the input number ofthe transformer and I1, I2, ...,
Inare the current of each input.
The addition is only possiblewhen the input currents
TSR-2
CONEXIN Y DIMENSIONES/ CONNECTION AND DIMENSIONS
Fig. 1
Fig. 2 Fig. 3
-
M.7 / 39
Tran
sfor
mad
ores
de
corr
ient
e. M
edid
a y
prot
ecci
n
Cdigos
CARACTERSTICAS TCNICAS TECHNICAL CHARACTERISTICS
Codes
TSR
Normas StandardsIEC 44-1, UNE 21 088, UL 94, VDE 0414
2 24 0112 24 0122 24 0132 24 014
TSR-2 (2 entradas x 5 A)TSR-3 (3 entradas x 5 A)TSR-4 (4
entradas x 5 A)TSR-5 (5 entradas x 5 A)
TSR-2 (2 input circuits x 5 A)TSR-3 (2 input circuits x 5
A)TSR-4 (4 input circuits x 5 A)TSR-5 (5 input circuits x 5 A)
* Bajo demanda pueden fabricase transformadores para cualquier
nmero de entradas
* On request more input circuits are available
Nmero de circuitos a sumarPotencia de salidaPrecisinClase
trmicaCorriente circuito entradaCorriente circuito salidaCorriente
trmica decortocircuito asignada (Ith)Sistema de fijacin:Acoplable a
rail DIN 46 277 (EN 50022)ProteccinSistema de fijacin: acoplablea
perfil simtrico DIN 46277 (EN 50022)Peso
2, 3, 4, / or 5 *15 VA
Clase / Class 0,5A
In / 5 A5 A60 I
n
IP 20
0,80 kg
Number of input circuitsOutput power
AccuracyThermal class
Input circuit currentOutput circuit current
Rated short-timethermal current (Ith)
Fixing system:fixing on a DIN 46277 (EN 50022) rail
ProtectionFixing system: fixing onto as
symmentrical DIN 46277 (EN 50022) railWeight
-
Curr
ent
tran
sfor
mer
s. M
easu
ring
and
pro
tect
ion
M.7 / 40
TRANSFORMADOR ADAPTADORDE IMPEDANCIASerie TE
Es frecuente en instalaciones elctricas tener quetransportar una
seal de 5 A procedente de untransformador de corriente hasta
equipos de medidaque se encuentran a una distancia considerable.
Lasprdidas que se producen en la lnea que une eltransformador con
el equipo demedida en algunos casos, sonsuperiores a la potencia
deltransformador, producindoseimportantes errores de medida.
Los transformadores elevadores deimpedancia solucionan este
problemaal transformar la seal de 5 A en unaseal de 0.1 A, fcil de
transportarcon conductores de muy pocaseccin y prdidas
insignificantes. Para convertir denuevo la seal de 0.1 A a 5 A se
coloca al final de lalnea que transporta la seal un transformador
deidnticas caractersticas con entrada 0.1 A y salida a5 A.
IMPEDANCE ADAPTERTRANSFORMERTE Series
Currents of 5 A coming from measurements orcontrol transformers
may have to be connected atlong distances. In this case the line
losses may bevery high, even greater than the available power
fromthe measuring transformer. This will cause important
errors in the measuring or controlprocess.
In these cases the impedanceadapter transformers offer a
solutionconsisting of one currenttransformer at the beginning of
theline with a ratio 5 A / 0.1 A andanother at the end side with a
ratio0.1 A / 5 A (the same type oftransformer inverting the
input/
output connection). The current of 100 mA sentthrough the line,
which may have smaller section andwith reduced losses.
CARACTERSTICAS TCNICAS TECHNICAL CHARACTERISTICSTE
IEC 44-1, UNE 21 088, UL 94, VDE 0414
2 25 001Cdigo Code
Primary side currentSecondary side current
Output powerAccuracy
Working temperatureMaximum permanent overload
Transient overloadProtection
Weight
5 A0,1 A15 VA
Clase / Class 1-25 / +50 C
1,2 In
20 In durante / for 1s
IP 400,75 kg
Corriente primariaCorriente
secundariaPotenciaPrecisinTemperatura de trabajoCorriente mxima
permanenteCorriente mxima circuitoProteccinPeso
Normas Standards
DIMENSIONES / DIMENSIONS
-
M.7 / 41
Tran
sfor
mad
ores
de
corr
ient
e. M
edid
a y
prot
ecci
nTRANSFORMADOR DE CORRIENTECON CONVERTIDOR INCORPORADO
4...20 mA c.c.(alimentacin externa o interna)
En muchas instalaciones y procesos de control esnecesario
disponer de una seal en corriente entre 4y 20 mA. Actualmente se
consigue mediante untransformador de corriente .../5 A, ms un
convertidor5 A / 4...20 mA.
CIRCUTOR ofrece una amplia gama de equipos queincorporan
transformador-convertidor en un slomdulo, sustituyendo los sistemas
convencionales.
Estos convertidores incluyen un transformador decorriente
constituido por el conductor activo queabarca el transformador como
primario y unarrollamiento secundario bobinado en un
ncleoferromagntico. Todos los tipos disponen de unasalida de 4...20
mA con una respuesta en frecuencialineal entre 50 y 60 Hz.
La principal aplicacin de los convertidores es suconexin a
Autmatas programables. Tambinpueden usarse en cualquier proceso
industrial osistema de control que necesite una seal lineal
encorriente de 4...20 mA.
Los equipos pueden alimentarse en corrientecontinua (10...28 V
c.c.), o bien en corriente alterna(230 V c.a.) segn la serie
seleccionada.
CURRENT TRANSFORMER WITHBUILT-IN CONVERTER
4...20 mA d.c.(external or internal supply)
In many installations and control processes it isnecessary to
have a current signal between 4 and20 mA. This signal is presently
obtained by means ofa .../5 A current transformer together with a 5
A /4...20 mA converter.
CIRCUTOR offers a wide range of equipmentsincorporating the
transformer-converter single module,which that substitute the
classic systems.
These converters have a current transformerconsisting of an
active conductor as primary winding,and a secondary winding coiled
around aferromagnetic core. All of the types have a 4...20 mAoutput
with a frequency response that is linearbetween 50 and 60 Hz.
The main application of these converters is theirconnection
to