Oil Furnace ModelsCentral heating oil furnace models are designed to meetU.L.standards and are certified by ETL. Limit setting andrating data were established and approved understandard rating conditions using U.L.
Safe OperationOil furnace models ship with Beckett Burners that utilizecad cells for flame sensing and a safety lockout featureto prevent excess oil buildup in the combustionchamber if ignition fails. The burner also includes avalve delay on cycle and clean cut solenoid valve forsmooth ignition.
Quick HeatingDurable, cycle tested, hot rolled, 13 gauge steel heatexchanger quickly transfers heat to provide warmconditioned air to the structure.
BurnerModel AF Beckett Burner with valve delay on & "clean-cut" oil pump for safety and efficient combustion.
ControlsProven fan limit control for reliable operation isadjustable to avoid cold drafts. The oil furnace fancenter is rated at 40VA for use with a cooling systemand accessories.
Air DeliveryMultispeed, direct drive blower motor, has sufficientairflow for most heating and cooling requirements, willswitch from heating to cooling speeds on demand fromroom Comfort Control. Variable speed models tailor airflow for varied cooling capacities.
StylingHeavy gauge, steel cabinet construction with powderpaint for attractive appearance and durability. The heatexchanger section of the cabinet is completely lined withfoil faced fiberglass insulation and the blower compart-ment includes a sound reduction insulation. Thisresults in quiet and efficient operation due to the excel-lent acoustical and insulating qualities of fiberglass. Abottom pan is built into the blower compartment withalternate back, left side or right side return air connec-tion provision.
3Pub. No. 22-1757-08
Contents
Feature Summary
Features and Benefits
Standard Equipment
Optional Equipment
General Data
THV1M087A936SA
THV1M087A948SA
TLF1M087A936SA
TLF1M087A948SA
TLR1M087A936SA
TLR1M087A948SA
TDF1M087A936SA
TDF1M087A948SA
THV1M087A9V3SA
THV1M087A9V5SA
TLF1M087A9V3SA
TLF1M087A9V5SA
TLR1M087A9V3SA
TLR1M087A9V5SA
TDF1M087A9V3SA
TDF1M087A9V5SA
Performance Data
Electrical Data
Field Wiring
Dimensions
2
4
6
6
6
6
6
6
6
6
6
7
7
7
7
7
7
7
7
9
17
21
24
4 Pub. No. 22-1757-08
Featuresand Benefits
� Up to 85.0% Annual FuelUtilization Efficiency (AFUE)
� 13 gauge hot rolled steel wraparound heat exchanger fordurability
� Beckett Flame Retention Burneroperates cleanly and quietly
� Burner features include primarycontrol with interrupted ignitionfor reliability, pre-purge andclean cutoff solenoid valve forsmooth ignition
� Burner and controls factory wired� Dual clean out ports for quick
access and easy cleaning� Direct drive, permanently
lubricated, 4 speed blowermotor on XP models
� Variable speed blower motors onXV models
� Insulated blower compartment� Slide out blower assembly for
quick cleaning and serviceaccessibility
� Filter rack with cleanable filter(Highboy & Lowboy Models only)
� Preformed ceramic fibercombustion chamber for higherefficiencies and more completecombustion
� 40 VA control transformer foradd on cooling
� Heavy gauge, painted steelcabinet
� Recessed door handles for easyremoval of Highboy & LowboyFurnace doors
� Lowboy models available withfront or rear flue
� Highboy models with top or rightside venting
� Downflow/Horizontal model fieldconvertible from downflow toright or left horizontal
� 6” Left and Right sidefresh air knockouts(Highboy & Lowboy Models only)
� Barometric draft regulatorincluded
� Heat exchanger cabinet sectionlined with foil faced insulation
Oil Pump Pressure (PSIG): 130Burner Head Type: F3Head / Turbulator Setting: “Z” = 1.125 in.Air Band Setting: Fully-closedAir Shutter / Damper Setting: 5Overfire Draft (in. W.G.): 0.02Smoke Spot, Maximum (Bacharach Scale): # 1Carbon Dioxide, CO2, Maximum (%): 13Carbon Dioxide, CO2, Minimum (%): 12*Carbon Monoxide, CO (PPM) 0Oil Solenoid Valve Equipped: YESDelay valve on Time (sec):Postpurge Time (sec): NoneIgnition Type: Interrupted
15 sec.
Oil Burner Application and Specifications* When operating these furnaces at the lowest input rate (84,000 BTUH), the carbon dioxide (CO2) value maynot be able to be adjusted above 12%. This is normal and does not necessarily indicate a problem.
High Limit Comfort Control Setting (deg. F.):230 (highboy / lowboy models)190 (horizontal / downflow model)
Fan “On” Setting (deg. F.): 130
Fan “Off” Setting (deg. F.): 100
Standard Fan Speed as shipped Low, Orange Wire to “L” Terminal
Standard Furnace Fan / Limit Control and Speed Settings
9Pub. No. 22-1757-08
PerformanceData
Furnace Airflow (CFM) vs. External Static Pressure (in. WC)
Model Speed Tap 0.1 0.2 0.3 0.4 0.5 0.6 0.7
HighboyTHV1M087A936SA
High 1508 1468 1407 1345 1278 1202 1120
Med-High 1420 1361 1310 1242 1176 1096 1019
Med-Low 1308 1263 1220 1174 1103 1031 953
Low 1189 1150 1113 1072 1009 936 870
HighboyTHV1M087A948SA
High 1974 1913 1854 1766 1695 1621 1547
Med-High 1694 1643 1589 1534 1477 1406 1339
Med-Low 1413 1384 1348 1315 1280 1235 1184
Low 1166 1144 1127 1105 1076 1027 983
LowboyFront Flue
TLF1M087A936SA
High 1688 1648 1595 1522 1447 1373 1309
Med-High 1372 1331 1290 1246 1200 1146 1079
Med-Low 1173 1156 1134 1108 1082 1043 989
Low 999 993 975 956 931 888 807
LowboyFront Flue
TLF1M087A948SA
High 1920 1822 1730 1649 1564 1483 1397
Med-High 1620 1572 1511 1443 1376 1311 1224
Med-Low 1358 1339 1309 1264 1216 1167 1098
Low 1103 1106 1080 1056 1023 981 858
LowboyRear Flue
TLR1M087A936SA
High 1669 1599 1541 1475 1409 1329 1231
Med-High 1410 1345 1299 1246 1184 1127 1171
Med-Low 1196 1184 1149 1111 1066 1023 938
Low 1007 1004 985 963 915 845 749
LowboyRear Flue
TLR1M087A948SA
High 1844 1771 1694 1612 1538 1451 1355
Med-High 1622 1545 1484 1419 1356 1274 1172
Med-Low 1366 1330 1303 1247 1187 1124 1046
Low 1110 1107 1091 1068 1031 973 887
Downflow/HorizontalTDF1M087A936SA
High 1616 1550 1482 1406 1347 1231 1144
Med-High 1447 1397 1343 1284 1209 1127 1043
Med-Low 1320 1274 1228 1176 1111 1043 950
Low 1166 1139 1107 1064 1017 955 871
Downflow/HorizontalTDF1M087A948SA
High 1901 1837 1790 1714 1648 1584 1496
Med-High 1615 1572 1521 1468 1412 1355 1308
Med-Low 1355 1342 1311 1273 1230 1183 1133
Low 1116 1105 1084 1058 1038 1001 955
10 Pub. No. 22-1757-08
NOTES:1. **FACTORY SETTING.2. CONTINUOUS FAN SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50% OF SELECTED COOLING VALUE.3. FOR VARIABLE SPEED: LOW SPEED AIRFLOWS ARE APPROXIMATELY 30% OF LISTED VALUES.4. LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATION FOR COMFORT & HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING.
TLR/F1M087A9V5SA OIL FURNACE COOLING AND HEATING AIRFLOW AND POWER VS. EXTERNAL STATIC PRESSURE WITH FILTER
PerformanceData
NOTES:1. **FACTORY SETTING.2. CONTINUOUS FAN SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50% OF SELECTED COOLING VALUE.3. FOR VARIABLE SPEED: LOW SPEED AIRFLOWS ARE APPROXIMATELY 30% OF LISTED VALUES.4. LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATION FOR COMFORT & HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING.
THV1M087A9V3SA OIL FURNACE COOLING AND HEATING AIRFLOW AND POWER VS. EXTERNAL STATIC PRESSURE WITH FILTER
PerformanceData
NOTES:1. **FACTORY SETTING.2. CONTINUOUS FAN SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50% OF SELECTED COOLING VALUE.3. FOR VARIABLE SPEED: LOW SPEED AIRFLOWS ARE APPROXIMATELY 30% OF LISTED VALUES.4. LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATION FOR COMFORT & HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING.
THV1M087A9V5SA OIL FURNACE COOLING AND HEATING AIRFLOW AND POWER VS. EXTERNAL STATIC PRESSURE WITH FILTER
PerformanceData
NOTES:1. **FACTORY SETTING.2. CONTINUOUS FAN SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50% OF SELECTED COOLING VALUE.3. FOR VARIABLE SPEED: LOW SPEED AIRFLOWS ARE APPROXIMATELY 30% OF LISTED VALUES.4. LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATION FOR COMFORT & HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING.
TDF1M087A9V3SA OIL FURNACE COOLING AND HEATING AIRFLOW AND POWER VS. EXTERNAL STATIC PRESSURE WITH FILTER
PerformanceData
NOTES:1. **FACTORY SETTING.2. CONTINUOUS FAN SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50% OF SELECTED COOLING VALUE.3. FOR VARIABLE SPEED: LOW SPEED AIRFLOWS ARE APPROXIMATELY 30% OF LISTED VALUES.4. LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATION FOR COMFORT & HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING.
TDF1M087A9V5SA OIL FURNACE COOLING AND HEATING AIRFLOW AND POWER VS. EXTERNAL STATIC PRESSURE WITH FILTER
PerformanceData
NOTES:1. **FACTORY SETTING.2. CONTINUOUS FAN SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50% OF SELECTED COOLING VALUE.3. FOR VARIABLE SPEED: LOW SPEED AIRFLOWS ARE APPROXIMATELY 30% OF LISTED VALUES.4. LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATION FOR COMFORT & HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING.
The unshaded area is the recommended operating range for HEATING comfort
17Pub. No. 22-1757-08
ElectricalData
ELE
CT
RIC
AL
DIA
GR
AM
S F
OR
PS
C 4
SP
EE
D B
LOW
ER
DO
WN
FLO
W /
HO
RIZ
ON
TAL
FU
RN
AC
ES
18 Pub. No. 22-1757-08
ElectricalData
ELE
CT
RIC
AL
DIA
GR
AM
S F
OR
PS
C 4
SP
EE
D B
LOW
ER
HIG
HB
OY
& L
OW
BO
Y F
UR
NA
CE
S
19Pub. No. 22-1757-08
ElectricalData
20 Pub. No. 22-1757-08
ElectricalData
21Pub. No. 22-1757-08
FieldWiring
LOW VOLTAGE HOOK UP DIAGRAMS FOR OIL FURNACE & SINGLE STAGE COOLING PSC 4 SPEED MOTORS
RCRC
B/C
COMFORTCONTROL
AIRCONDITIONER
FURNACEFAN CENTER
OIL BURNER PRIMARY
R1
R1
B/C
COMFORTCONTROL
AIRCONDITIONER
FURNACEFAN CENTER
OIL BURNER PRIMARY
COMFORT CONTROL
Blower Motor Terminal Blocks and Wiring
22 Pub. No. 22-1757-08
FieldWiring
VARIABLE SPEED LOW VOLTAGE HOOK UP DIAGRAMS FOR OIL FURNACE AND SINGLE STAGE COOLING
Low VoltageTerminal BoardMAKE LOW VOLTAGECONNECTIONS HERE
Oil BurnerPrimary Control
DO NOT MAKE ANY CONNECTIONS HERE
Route electrical power circuit through outside furnace wall and into junction box and make high voltage connections inside box according to the NEC and local codes.
VARIABLE SPEED V3, V5 LOW VOLTAGE WIRINGCONNECTIONS LOCATIONS
R
G
Y/ Y1
W1
B
COMFORTCONTROL
VARIABLE SPEED OIL FURNACE SINGLE STAGE COOLING
R
G
W1
W2
Y1/YLO
B
SINGLE STAGE AIR CONDITIONER
ONE STAGE VS OIL FURNACE
BC
BK
Y/Y2 Y
W3
O
R1
R1
"R" to "O" and "R" to "BK" are Factory Installed Jumpers
R1
OIL BURNER PRIMARY
23Pub. No. 22-1757-08
FieldWiring
VARIABLE SPEED LOW VOLTAGE HOOK UP DIAGRAMS FOR OIL FURNACE AND TWO STAGE / STEP COOLING
R
G
Y/ Y1
W1
B
COMFORTCONTROL
VARIABLE SPEED OIL FURNACE TWO STAGE COOLINGWITH 24V RELAY
R
G
W1
W2
Y1/YLO
Y1
B
TWO STAGE AIR CONDITIONER
ONE STAGE VS OIL FURNACE
BC
Y2
BK
Y/Y2 Y2
R
O
W3
R1
"R" to "O" and "R" to "BK" are Factory Installed Jumpers
R1
OIL BURNER PRIMARY
R
G
Y/ Y1
W1
B
COMFORTCONTROL
VARIABLE SPEED OIL FURNACE TWO STEP COOLING WITH 24V RELAY
R
G
W1
W2
Y1/YLO
B
TWO STEPAIR CONDITIONER
ONE STAGE VSOIL FURNACE
BC
Y2 BK
Y/Y2 Y1
O
Y2
Note A - Cut/remove the factory installed "R" to "BK" jumper at the indoor unit.
W3
R1
Note A
"R" to "O" and "R" to "BK" are Factory Installed Jumpers
R1
OIL BURNER PRIMARY
24 Pub. No. 22-1757-08
Dimensions
Hig
hboy
Ver
tical
Hig
hboy
Ver
tical
16.13 16.13
14.16 14.16
25.0
025
.00
24.0
424
.04
47.13 47.13
58.00 58.00
31.0
331
.03 20
.020
.00.
100.
10
0.070.07
4.45
4.45
6.50
6.50
1.18
1.18
22.1
322
.13
20.0
320
.03
4.59 4.59
10.06 10.06
LC
6.506.50
34.25 34.25
26.00 26.00
19.00 19.00
1.00
1.00
0.88
0.88
6.00
6.00
1.00 1.00
4.54
4.54
3.75
3.75
* N
OTE
: Filt
er F
ram
e
Shi
pped
una
ssem
bled
& p
acke
d in
blo
wer
c
ompa
rtm
ent
MIN
IMU
M C
LE
AR
AN
CE
TO
CO
MB
US
TIB
LE
MA
TE
RIA
LS
Fu
rnac
e ca
sin
g s
ides
an
d r
ear
3"
Fro
nt
furn
ace
casi
ng
to
clo
set
do
or1
8"
Fu
rnac
e fl
ue
pip
e / v
ent
con
nec
tor
9"
Fu
rnac
e ca
sin
g t
op
3"
Su
pp
ly a
ir p
len
um
(an
y si
de)
3"
Su
pp
ly a
ir d
uct
s w
ith
in 6
fee
t o
f th
e fu
rnac
e.3"
THV
1M08
7A93
6, 4
8, V
3, V
5SA
OU
TLIN
E D
RA
WIN
G(A
LL D
IME
NS
ION
S A
RE
IN IN
CH
ES
)
25Pub. No. 22-1757-08
Dimensions
61.2
561
.25
11.12 11.12
29.8
229
.82
16.1
316
.13
16.13 16.13
16.1
316
.13
22.2
522
.25
Dow
nflo
w /
Hor
izon
tal -
Fro
nt F
lue
Dow
nflo
w /
Hor
izon
tal -
Fro
nt F
lue
0.75
0.75
0.75
0.75
16.13 16.13
22.25 22.25
3.23 3.23
AIRF
LOW
MIN
IMU
M C
LE
AR
AN
CE
TO
CO
MB
US
TIB
LE
MA
TE
RIA
LS
Fu
rnac
e ca
sin
g s
ides
an
d r
ear
3"
Fro
nt
furn
ace
casi
ng
to
clo
set
do
or1
8"
Fu
rnac
e fl
ue
pip
e / v
ent
con
nec
tor
9"
Fu
rnac
e ca
sin
g t
op
3"
Su
pp
ly a
ir p
len
um
(an
y si
de)
3"
Su
pp
ly a
ir d
uct
s w
ith
in 6
fee
t o
f th
e fu
rnac
e.3"
No
tes:
1 T
he
Ho
rizo
nta
l / D
ow
nfl
ow
mo
del
req
uir
es 2
2" f
rom
th
e fr
on
t ca
sin
g o
f th
e fu
rnac
e to
th
ecl
ose
t d
oo
r.2
Ad
equ
ate
clea
ran
ce f
rom
th
e su
pp
ly e
nd
su
rfac
e o
f th
e fu
rnac
e ca
sin
g t
o c
om
bu
stib
lem
ater
ials
are
pro
vid
ed b
y th
e d
esig
n o
f th
e ac
cess
ory
mo
un
tin
g b
ase
wh
en u
sed
wit
h t
he
Ho
rizo
nta
l / D
ow
nfl
ow
fu
rnac
e m
od
el a
pp
lied
in t
he
Do
wn
flo
w c
on
fig
ura
tio
n.
TDF1
M08
7A93
6, 4
8, V
3, V
5SA
OU
TLIN
E D
RA
WIN
G(A
LL D
IME
NS
ION
S A
RE
IN IN
CH
ES
)
26 Pub. No. 22-1757-08
Dimensions
4.54 4.54
1.00
1.00
10.8
810
.88
6.00
6.00
Low
boy
- Fr
ont F
lue
Low
boy
- Fr
ont F
lue
0.630.63
10.0
610
.06
10.13 10.13
47.0
047
.00
20.0
320
.03
12.5
312
.53
2.38
2.38
2.00
2.00
4.50
4.50
40.75 40.75
0.72 0.72
22.0
622
.06
20.0
320
.03
17.00 17.00
1.00 1.00
3.13 3.13
3.75
3.75
6.50
6.50
LC
MIN
IMU
M C
LE
AR
AN
CE
TO
CO
MB
US
TIB
LE
MA
TE
RIA
LS
Fu
rnac
e ca
sin
g s
ides
an
d r
ear
3"
Fro
nt
furn
ace
casi
ng
to
clo
set
do
or1
8"
Fu
rnac
e fl
ue
pip
e / v
ent
con
nec
tor
9"
Fu
rnac
e ca
sin
g t
op
3"
Su
pp
ly a
ir p
len
um
(an
y si
de)
3"
Su
pp
ly a
ir d
uct
s w
ith
in 6
fee
t o
f th
e fu
rnac
e.3"
TLF1
M08
7A93
6, 4
8, V
3, V
5SA
OU
TLIN
E D
RA
WIN
G(A
LL D
IME
NS
ION
S A
RE
IN IN
CH
ES
)
27Pub. No. 22-1757-08
Dimensions
2.05
2.05
Low
boy
Rea
r F
lue
Low
boy
Rea
r F
lue
1.00
1.000.
880.
88
6.00
6.00
0.630.63
10.0
610
.06
10.13 10.13
47.0
047
.00
20.0
320
.03
12.5
312
.53
2.38
2.38
2.00
2.00
4.50
4.50
40.75 40.75
0.72 0.72
22.0
622
.06
20.0
320
.03
17.00 17.00
1.00 1.00
3.13 3.13
3.75
3.75
29.845 29.845
MIN
IMU
M C
LE
AR
AN
CE
TO
CO
MB
US
TIB
LE
MA
TE
RIA
LS
Fu
rnac
e ca
sin
g s
ides
an
d r
ear
3"
Fro
nt
furn
ace
casi
ng
to
clo
set
do
or1
8"
Fu
rnac
e fl
ue
pip
e / v
ent
con
nec
tor
9"
Fu
rnac
e ca
sin
g t
op
3"
Su
pp
ly a
ir p
lenu
m (
any
sid
e)3"
Su
pp
ly a
ir d
uct
s w
ith
in 6
fee
t o
f th
e fu
rnac
e.3"
No
tes:
1 L
ow
boy
Rea
r F
lue
mo
del
req
uir
es 3
" fr
om
th
e fu
rnac
e fr
on
t ca
sin
g t
o t
he
clo
set
do
or.
TLR
1M08
7A93
6, 4
8, V
3, V
5SA
OU
TLIN
E D
RA
WIN
G(A
LL D
IME
NS
ION
S A
RE
IN IN
CH
ES
)
Since Trane has a policy of continuous product improvement, it reserves the right to change design andspecifications without notice.