Page 1
©TRAK Microwave Corp. Doc #FL309 01/03 1
TRAK MicrowaveIsolator and Cir culator Catalog
Intr oduction
TRAK Microwave has a long histor y in design and pr oduction of high r eliability isolators and circulatorsdating back to 1969. Thr ough these years, TRAK Microwave has developed the reputation for innovative,high quality RF and microwave components, integrated assemblies and subsystems. Even thoughdesigns, products, and applications have changed thr ough the years, our unmatched commitment tocustomers has not.
Catalog Ca pa bilitiesTRAK isolators and circulators cover a broad range offrequencies for various applications in defense, space andcommercial markets. The performance specificationsprovided are generally conservative and allow for variationswithin operating temperatur e ranges at various RFpowerlevels. Typical package drawings are shown, but do notrepresent all possibilities available.
Not included in this catalog ar e a myriad of isolator andcirculator custom designs such as waveguide to coaxialisolators and multi-junction devices. TRAK welcomes theopportunity to custom design solutions specific to yourapplications and environmental needs.
Together, these standard and custom pr oduct families makeup the TRAK portfolio of isolator and circulator products thatspan the UHF to millimeter fr equency bands operating fr omlow to high power under the most sever e environmentalconditions.
Company Ca pa bilitiesTRAK Microwave is a prominent leader in isolator andcirculator design and supply . TRAKhas expanded andstrengthened its technical capabilities and is highlyregarded for sustaining pr ogram heritage. As one ofthe largest suppliers of isolators and circulators, TRAKisequally adept in defense, space, and commercialapplications.
Isolator and circulator development teams are based inTRAK facilities located in the United States and UnitedKingdom. These locations provide customers with on-going efficient technical support and effective pr oductdevelopment. TRAK engineers use advanced design toolsand software to support design and pr ototype activities.The design team, in conjunction with the TRAK sales andnetwork of r epresentatives, interact closely with customersto ensure that performance and pr ogram objectives are met in the most efficient and effective manner possible.
コーンズ ドッドウェル株式会社 第二営業本部 デバイス営業部 東京:03-5774-9978 大阪:06-6532-1012URL:http://www.cornes-dodwell.co.jp/ e-mail:[email protected]
Page 2
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/032
TRAK MicrowaveIsolator and Circulator Catalog
Introduction
Product Capabilities TRAK products have evolved to meet or exceed each new customer demand, which has resulted in a broad range ofcompact, robust, high performance devices.
Most housings for isolators or circulators are milled fromMartensitic stainless steel and are nickel-plated to providea stable, yet cosmetically pleasing finish. Other finishes such as silver or gold are optional. TRAK devices are assembledunder compression, which improves the rigidity andbenefits performance over wide temperature ranges.With no epoxies used internal to the microwave circuit,insertion losses are also optimized.
Contributing factors to the minimized size include the use of high dielectric rings around the circumference, rare earth magnets, steel, and in the case of the coaxial range, proprietary SMA connectors. The devices will operate overconsiderably wider temperature ranges, for example(-54˚ to +95˚C). However, minor microwave performance degradation may be apparent.
All the devices offered are capable of commercial tocomplete military or space qualified standards includingshocks in excess of 150g, sinusoidal vibration in excess of25g peak from 10 - 2,000 Hz, and humidity. Each deviceoffers reliable performance over a wide temperature rangeoperating in harsh environments without compromise ofelectrical performance.
Our global defense customers rely on our capability and high volume capacity to produce parts for long-term phasedarray programs. TRAK has a Hi-Rel section devoted exclusively to military or space application programs and usesclean rooms, space approved epoxies, and other polymeric compounds. TRAK product families offer a balancebetween practicality and affordability, while optimizing reliability and performance.
For further information, visit our web site at www.trak.com, contact your local TRAK representative or contact TRAK directly at:
US Toll Free: 888.283.8444 � US Phone: 813.901.7200 � US Fax: 813.901.7491
Int’l. Phone: 44.1382.427200 � Int’l. Fax: 44.1382.833599
Email: [email protected] � www.trak.com
TRAK Microwave is an IS0 9001 registered company.
Page 3
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/03 3
Specifications subject to change without notice.
Coaxial Isolators
� Magnetically Shielded
� SMA M/F Connectors Standard
� Ideal General Purpose Device
� Military, Space, and Commercial Applications
�Wide Operating Temperature
� Compact, Rugged Construction
� Rich Design Portfolio
� Extensive Program Heritage
Broadband Coaxial Isolator SpecificationsModels in bold text are normally in stock for immediate delivery.
FREQUENCY MODEL ISOLATION INS LOSS VSWR OPERATING PWR HANDLING PACKAGE(GHz) NUMBER (dB) MIN (dB) MAX MAX TEMP(˚C) PK/FWD/REV (W) CODE
0.490 - 0.710 T049071/DB 19 0.50 1.25:1 0 to +50 1000 / 80 / 1 L1
0.950 - 1.225 T095012/DB 19 0.50 1.25:1 -25 to +85 1000 / 80 / 1 L1
1.000 - 2.000 T1020/DB 15 0.70 1.40:1 0 to +50 500 / 100 / 1 G1
2.000 - 4.000 T2040/DB 18 0.50 1.30:1 0 to +70 500 / 60 / 1 H1
2.000 - 6.000 T2060/DB 12 1.00 1.80:1 -10 to +60 500 / 10 / 1 H2
2.200 - 2.800 T2228/DB 21 0.30 1.20:1 -25 to +85 500 / 120 / 1 H1
2.600 - 5.200 T2652/DB 18 0.50 1.30:1 -25 to +85 500 / 60 / 1 H1
2.700 - 6.000 T2760/DB 16 0.60 1.45:1 -25 to +85 500 / 30 / 1 I1
2.800 - 3.800 T2838/DB 19 0.50 1.25:1 -25 to +85 500 / 80 / 1 I1
3.000 - 6.000 T3060/DB 18 0.50 1.40:1 -25 to +85 500 / 40 / 1 I1
3.000 - 6.600 T3066/DB 16 0.60 1.45:1 -25 to +85 500 / 30 / 1 I1
3.400 - 4.200 T3442/DC 21 0.30 1.20:1 -25 to +85 500 / 120 / 1 H1
3.400 - 4.200 T3442/DD 18 0.60 1.30:1 -25 to +85 500 / 60 / 1 J1
3.600 - 7.500 T3675/DB 21 0.50 1.20:1 -25 to +85 500 / 120 / 1 I1
3.700 - 8.000 T3780/DB 18 0.50 1.30:1 -25 to +85 500 / 60 / 1 I1
4.000 - 5.000 T4050/DB 21 0.40 1.20:1 0 to +70 500 / 120 / 1 I1
4.000 - 8.000 T4080/DG 18 0.50 1.30:1 -25 to +85 500 / 60 / 1 I1
5.000 - 10.000 T500100/DB 19 0.50 1.35:1 -25 to +85 500 / 50 / 1 I1
5.000 - 11.000 T500110/DB 14 0.50 1.50:1 -25 to +85 500 / 30 / 1 J1
6.000 - 12.000 T600120/DB 15 0.60 1.40:1 -25 to +85 500 / 40 / 1 I1
6.000 - 18.000 T600180/DB 12 1.10 1.70:1 -25 to +85 500 / 10 / 1 K1
6.500 - 18.000 T650180/DB 12 1.10 1.50:1 -25 to +85 500 / 30 / 1 K1
7.000 - 9.000 T7090/DB 21 0.40 1.20:1 -25 to +85 500 / 65 / 1 J1
7.000 - 10.000 T700100/DB 19 0.50 1.25:1 -25 to +85 500 / 65 / 1 J1
7.000 - 18.000 T700180/DB 12 0.90 1.65:1 -25 to +85 500 / 20 / 1 K1
7.500 - 18.000 T750180/DB 17 0.90 1.30:1 -25 to +85 500 / 60 / 1 J1
8.000 - 10.000 T800100/DD 22 0.50 1.20:1 -25 to +85 500 / 65 / 1 J1
8.000 - 12.400 T800124/DL 20 0.50 1.25:1 -25 to +85 500 / 65 / 1 J1
Page 4
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/034
Specifications subject to change without notice.
FREQUENCY MODEL ISOLATION INS LOSS VSWR OPERATING PWR HANDLING PACKAGE(GHz) NUMBER (dB) MIN (dB) MAX MAX TEMP(˚C) PK/FWD/REV (W) CODE
0.390 - 0.450 T039045/DB 18 0.40 1.30:1 0 to +50 1000 / 60 / 1 G1
0.420 - 0.450 T042045/DB 18 0.40 1.30:1 0 to +50 1000 / 60 / 1 L1
0.800 - 0.960 T080096/DB 19 0.40 1.25:1 -25 to +85 1000 / 80 / 1 L1
0.850 - 0.950 T085095/DB 19 0.50 1.30:1 -25 to +85 1000 / 60 / 1 H1
1.000 - 1.100 T1011/DB 20 0.50 1.25:1 -25 to +85 1000 / 80 / 1 H1
1.200 - 1.400 T1214/DB 22 0.40 1.20:1 -25 to +85 1000 / 80 / 1 H1
1.435 - 1.535 T1415/DB 20 0.50 1.25:1 -25 to +85 1000 / 80 / 1 H1
1.500 - 1.600 T1516/DB 21 0.30 1.20:1 -25 to +85 1000 / 120 / 1 H1
1.600 - 1.800 T1618/DB 19 0.40 1.25:1 -25 to +85 1000 / 65 / 1 I1
1.800 - 2.100 T1821/DB 18 0.50 1.35:1 -25 to +85 1000 / 125 / 1 I1
2.000 - 2.330 T2023/DB 20 0.50 1.25:1 -25 to +85 500 / 80 / 1 I1
2.100 - 2.300 T2123/DB 23 0.50 1.15:1 -25 to +85 500 / 80 / 1 I1
2.200 - 2.300 T2223/DB 20 0.40 1.25:1 -25 to +85 500 / 80 / 1 I1
2.200 - 2.500 T2225/DB 19 0.50 1.25:1 -25 to +85 500 / 80 / 1 I1
2.500 - 2.700 T2527/DB 21 0.30 1.20:1 -25 to +85 500 / 120 / 1 I1
2.700 - 3.100 T2731/DB 23 0.40 1.15:1 -25 to +85 500 / 120 / 1 I1
3.000 - 3.500 T3035/DB 20 0.50 1.25:1 -25 to +85 500 / 80 / 1 I1
3.700 - 4.200 T3742/DB 19 0.50 1.25:1 -25 to +85 500 / 65 / 1 J1
4.200 - 4.400 T4244/DB 21 0.50 1.20:1 -25 to +85 500 / 65 / 1 J1
5.150 - 5.650 T5156/DB 21 0.40 1.20:1 -25 to +85 500 / 65 / 1 J1
5.400 - 5.900 T5459/DB 19 0.50 1.25:1 -25 to +85 500 / 65 / 1 J1
5.850 - 6.650 T5866/DB 21 0.30 1.20:1 -25 to +85 500 / 65 / 1 J1
6.500 - 7.200 T6572/DB 20 0.50 1.25:1 -25 to +85 500 / 65 / 1 J1
6.700 - 7.100 T6771/DB 21 0.30 1.20:1 -25 to +85 500 / 65 / 1 J1
6.710 - 7.420 T6774/DB 19 0.50 1.25:1 -25 to +85 500 / 65 / 1 J1
7.000 - 7.700 T7077/DB 20 0.50 1.20:1 -25 to +85 500 / 65 / 1 J1
7.825 - 8.475 T7884/DB 21 0.40 1.20:1 -25 to +85 500 / 65 / 1 J1
8.500 - 9.600 T8596/DB 21 0.30 1.20:1 -25 to +85 500 / 65 / 1 J1
Broadband Coaxial Isolator SpecificationsModels in bold text are normally in stock for immediate delivery.
Coaxial Isolators
Narrowband Coaxial Isolator Specifications
FREQUENCY MODEL ISOLATION INS LOSS VSWR OPERATING PWR HANDLING PACKAGE(GHz) NUMBER (dB) MIN (dB) MAX MAX TEMP(˚C) PK/FWD/REV (W) CODE
8.000 - 16.000 T800160/DB 17 0.50 1.35:1 -25 to +85 500 / 50 / 1 J1
8.000 - 18.000 T800180/DB 14 0.50 1.50:1 -25 to +85 500 / 30 / 1 J1
8.000 - 20.000 T800200/DB 11 1.00 1.80:1 -25 to +85 500 / 10 / 1 J1
10.000 - 15.000 T100150/DB 21 0.40 1.20:1 -25 to +85 500 / 65 / 1 J1
12.000 - 15.000 T120150/DD 20 0.50 1.25:1 -25 to +85 500 / 65 / 1 J1
12.000 - 18.000 T120180/DF 19 0.50 1.25:1 -25 to +85 500 / 65 / 1 J1
12.000 - 20.000 T120200/DB 14 0.70 1.50:1 -25 to +85 500 / 30 / 1 J1
18.000 - 22.000 T180220/DB 18 0.70 1.30:1 -25 to +85 500 / 60 / 1 K2
18.000 - 26.500 T180265/DB 13 1.00 1.58:1 -25 to +85 500 / 20 / 1 K2
Page 5
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/03 5
Specifications subject to change without notice.
CENTER MODEL BANDWIDTH ISOLATION INS LOSS VSWR OPERATING PWR HANDLING PACKAGEFREQUENCY(GHz) NUMBER (%) (dB MIN) (dB MAX) MAX TEMP (˚C) PK/FWD/REV (W) CODE
0.500 - 0.700 T050070/S*D 5% 19 0.50 1.25:1 -20 to +70 1000 / 80 / 1 H1
0.700 - 1.000 T070010/S*B 5% 20 0.50 1.25:1 -25 to +85 1000 / 80 / 1 H1
1.000 - 1.300 T1013/S*B 10% 20 0.50 1.25:1 -25 to +85 1000 / 80 / 1 H1
1.300 - 1.650 T1316/S*C 10% 20 0.50 1.25:1 -25 to +85 1000 / 80 / 1 H1
1.300 - 1.650 T1316/S*D 10% 20 0.50 1.25:1 -25 to +85 1000 / 80 / 1 I1
1.650 - 2.000 T1620/S*D 10% 20 0.50 1.25:1 -25 to +85 1000 / 80 / 1 I1
2.000 - 2.500 T2025/S*D 10% 20 0.50 1.25:1 -25 to +85 500 / 80 / 1 I1
2.500 - 3.200 T2532/S*B 10% 20 0.50 1.25:1 -25 to +85 500 / 80 / 1 I1
3.000 - 3.800 T3038/S*B 10% 20 0.50 1.25:1 -25 to +85 500 / 80 / 1 I1
3.000 - 4.000 T3040/S*B 10% 20 0.50 1.25:1 -25 to +85 500 / 65 / 1 J1
3.600 - 5.000 T3650/S*B 10% 20 0.50 1.25:1 -25 to +85 500 / 65 / 1 J1
4.800 - 6.000 T4860/S*B 10% 20 0.50 1.25:1 -25 to +85 500 / 65 / 1 J1
6.000 - 8.000 T6080/S*B 15% 23 0.50 1.20:1 -25 to +85 500 / 65 / 1 J1
8.000 - 15.000 T800150/S*B 10% 23 0.50 1.20:1 -25 to +85 500 / 65 / 1 J1
15.000 - 18.000 T150180/S*B 10% 23 0.50 1.20:1 -25 to +85 500 / 65 / 1 J1
FREQUENCY MODEL ISOLATION INS LOSS VSWR OPERATING PWR HANDLING PACKAGE(GHz) NUMBER (dB) MIN (dB) MAX MAX TEMP(˚C) PK/FWD/REV (W) CODE
10.000 - 12.000 T100120/DD 20 0.50 1.25:1 -25 to +85 500 / 65 / 1 J1
10.500 - 11.300 T105113/DD 23 0.40 1.15:1 -25 to +85 500 / 65 / 1 J1
11.000 - 12.000 T110120/DB 21 0.40 1.20:1 -25 to +85 500 / 65 / 1 J1
11.000 - 12.790 T110127/DD 21 0.50 1.20:1 -25 to +85 500 / 65 / 1 J1
11.450 - 12.750 T114127/DA 23 0.30 1.15:1 -25 to +85 500 / 65 / 1 J1
12.000 - 12.800 T120128/DB 23 0.30 1.15:1 -25 to +85 500 / 65 / 1 J1
12.750 - 14.500 T127145/DB 23 0.40 1.15:1 -25 to +85 500 / 65 / 1 J1
13.000 - 15.000 T130150/DB 23 0.40 1.15:1 -25 to +85 500 / 65 / 1 J1
15.000 - 18.000 T150180/DF 20 0.50 1.20:1 -25 to +85 500 / 65 / 1 J1
19.440 - 21.500 T194215/DB 19 0.50 1.25:1 -25 to +85 500 / 65 / 1 J1
19.700 - 20.200 T197202/DE 21 0.50 1.20:1 -25 to +85 500 / 65 / 1 J1
Coaxial Isolators
Narrowband Coaxial Isolator Specifications
Select-A-Frequency Coaxial Isolator SpecificationsRefer to page 50 for Select-A-Frequency Instructions.
Page 6
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/036
Specifications subject to change without notice.
G1 - ISOLATOR
DIM = INCH MASS = 7 oz MAX
3
1 2
4X .156 THRU
2X .18
.25
3X .38
2X .33
.35
2X 1.14
1.60
2X 1.240
.751.60
2X 1.240
LCLLTERMINATION
2X .18
FEMALE CONN2X SMA
DIM = INCH MASS = 2.2 oz MAX
1
3
2
4X .080 THRU
.50
2X .09
2X .820
1.00
2X .69
.35
3X .25
2X .331.00
2X .8202X .09
.25 TERMINATION
FEMALE CONN2X SMA
CLCC
H1 - ISOLATOR
DIM = INCH MASS = 2.2 oz MAX
H2 - ISOLATOR
1
3
2
4X .080 THRU
.50
2X .09
2X .820
1.00
2X .69
.45
3X .25
2X .401.00
2X .8202X .09
.25 TERMINATION
FEMALE CONN2X SMA
CLCC
I1 - ISOLATOR
DIM = INCH MASS = 1.3 oz MAX
FEMALE CONN
2X .080 THRU
2X SMA3X .25
2X .33
.09
2X .09
.25
.75 .50
.75
.35
2X .505
.570
1
3
2
LCLL
TERMINATION
Coaxial Isolator Package Drawings
Coaxial Isolators
Page 7
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/03 7
Specifications subject to change without notice.
Coaxial Isolator Package Drawings
Coaxial Isolators
J1 - ISOLATOR
DIM = INCH MASS = .67 oz MAX
3
1 2
2X .075 THRU
2X SMAFEMALE
CONN
.50 .50
3X .25
2X .33
2X .33
2X .06
.06 .380
.35
.50
LCLL .25 TERMINATION
L1 - ISOLATOR
DIM = INCH MASS = 4.6 oz MAX
3
1 2
4X .156 THRU .25
2X 1.240
1.50
2X .13
2X .33
3X .25
.50
1.50
2X 1.09
.352X .13
2X 1.240
2X SMAFEMALE CONN
LCLLTERMINATION
K - ISOLATOR K1 K2
DIM = INCH MASS = .6 oz MAX
2X .075 THRU
.38
3X .19
.50
.20
.25
3X .19
.38
.50
.25
.35
.50 2X .33
2X .06
.380.06
2X .33
2X SMA FEMALE CONN
LCLL
TERMINATION
3
21
Page 8
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/038
Specifications subject to change without notice.
Coaxial Circulators
Broadband Coaxial Circulator SpecificationsModels in bold text are normally in stock for immediate delivery.
� Magnetically Shielded
� SMA M/F Connectors Standard
� Ideal General Purpose Device
� Military, Space, and Commercial Applications
�Wide Operating Temperature
� Compact, Rugged Construction
� Rich Design Portfolio
� Extensive Program Heritage
FREQUENCY MODEL ISOLATION INS LOSS VSWR OPERATING PWR HANDLING PACKAGE(GHz) NUMBER (dB) MIN (dB) MAX MAX TEMP(˚C) PK/AVG (W) CODE
0.490 - 0.710 C049071/DA 19 0.50 1.25:1 0 to +50 1000 / 300 L1
0.950 - 1.225 C095012/DA 18 0.50 1.30:1 -25 to +85 1000 / 300 L1
1.000 - 2.000 C1020/DA 15 0.70 1.40:1 0 to +50 500 / 100 G1
2.000 - 4.000 C2040/DA 18 0.50 1.30:1 0 to +70 500 / 125 H1
2.000 - 6.000 C2060/DA 12 1.00 1.80:1 -10 to +60 500 / 10 H2
2.200 - 2.800 C2228/DA 21 0.30 1.20:1 -25 to +85 500 / 125 H1
2.600 - 5.200 C2652/DA 20 0.50 1.30:1 -25 to +85 500 / 125 H1
2.700 - 6.000 C2760/DA 16 0.60 1.45:1 -25 to +85 500 / 125 I1
2.800 - 3.800 C2838/DA 19 0.50 1.25:1 -25 to +85 500 / 125 I1
3.000 - 6.000 C3060/DA 18 0.50 1.40:1 -25 to +85 500 / 125 I1
3.000 - 6.600 C3066/DA 16 0.60 1.45:1 -25 to +85 500 / 125 I1
3.400 - 4.200 C3442/DA 21 0.30 1.20:1 -25 to +85 500 / 125 H1
3.400 - 4.200 C3442/DB 18 0.60 1.30:1 -25 to +85 500 / 65 J1
3.600 - 7.500 C3675/DA 21 0.50 1.20:1 -25 to +85 500 / 125 I1
3.700 - 8.000 C3780/DA 18 0.50 1.30:1 -25 to +85 500 / 125 I1
4.000 - 5.000 C4050/DA 21 0.40 1.20:1 -25 to +85 500 / 125 I1
4.000 - 8.000 C4080/DF 18 0.50 1.30:1 -25 to +85 500 / 125 I1
5.000 - 10.000 C500100/DA 18 0.50 1.30:1 -25 to +85 500 / 125 I1
5.000 - 11.000 C500110/DA 14 0.50 1.50:1 -25 to +85 500 / 65 J1
6.000 - 12.000 C600120/DA 15 0.60 1.40:1 -25 to +85 500 / 75 I1
6.000 - 18.000 C600180/DA 12 1.20 1.80:1 -25 to +85 500 / 50 K1
6.500 - 18.000 C650180/DA 14 1.10 1.50:1 -25 to +85 500 / 50 K1
7.000 - 9.000 C7090/DA 21 0.40 1.20:1 -25 to +85 500 / 65 J1
7.000 - 10.000 C700100/DA 19 0.50 1.25:1 -25 to +85 500 / 65 J1
7.000 - 18.000 C700180/DA 12 0.90 1.65:1 -25 to +85 500 / 65 K1
7.500 - 18.000 C750180/DA 17 0.90 1.30:1 -25 to +85 500 / 65 J1
8.000 - 10.000 C800100/DC 22 0.50 1.20:1 -25 to +85 500 / 65 J1
8.000 - 12.400 C800124/DK 20 0.50 1.25:1 -25 to +85 500 / 65 J1
Page 9
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/03 9
Specifications subject to change without notice.
FREQUENCY MODEL ISOLATION INS LOSS VSWR OPERATING PWR HANDLING PACKAGE(GHz) NUMBER (dB) MIN (dB) MAX MAX TEMP(˚C) PK/AVG (W) CODE
0.390 - 0.450 C039045/DA 18 0.40 1.30:1 0 to +50 1000 / 300 G1
0.420 - 0.450 C042045/DA 20 0.40 1.25:1 0 to +50 1000 / 300 L1
0.800 - 0.960 C080096/DA 19 0.40 1.25:1 -25 to +85 1000 / 300 L1
0.850 - 0.950 C085095/DA 19 0.50 1.30:1 -25 to +85 1000 / 200 H1
1.000 - 1.100 C1011/DA 20 0.50 1.25:1 -25 to +85 1000 / 200 H1
1.200 - 1.400 C1214/DA 22 0.40 1.20:1 -25 to +85 1000 / 200 H1
1.435 - 1.535 C1415/DA 20 0.50 1.25:1 -25 to +85 1000 / 125 I1
1.500 - 1.600 C1516/DA 21 0.30 1.20:1 -25 to +85 1000 / 200 H1
1.600 - 1.800 C1618/DA 19 0.40 1.25:1 -25 to +85 1000 / 65 I1
1.800 - 2.100 C1821/DA 18 0.50 1.35:1 -25 to +85 1000 / 125 I1
2.000 - 2.330 C2023/DA 17 0.30 1.30:1 -25 to +85 500 / 125 I1
2.100 - 2.300 C2123/DA 23 0.50 1.15:1 -25 to +85 500 / 125 I1
2.200 - 2.300 C2223/DA 20 0.40 1.25:1 -25 to +85 500 / 125 I1
2.200 - 2.500 C2225/DA 19 0.50 1.25:1 -25 to +85 500 / 125 I1
2.500 - 2.700 C2527/DA 21 0.30 1.20:1 -25 to +85 500 / 125 I1
2.700 - 3.100 C2731/DA 23 0.40 1.15:1 -25 to +85 500 / 125 I1
3.000 - 3.500 C3035/DA 20 0.50 1.25:1 -25 to +85 500 / 125 I1
3.700 - 4.200 C3742/DA 21 0.40 1.20:1 -25 to +85 500 / 65 J1
4.200 - 4.400 C4244/DA 21 0.50 1.20:1 -25 to +85 500 / 65 J1
5.150 - 5.650 C5156/DA 21 0.40 1.20:1 -25 to +85 500 / 65 J1
5.400 - 5.900 C5459/DA 20 0.50 1.25:1 -25 to +85 500 / 65 J1
5.850 - 6.650 C5866/DA 21 0.30 1.20:1 -25 to +85 500 / 65 J1
6.500 - 7.200 C6572/DA 20 0.50 1.25:1 -25 to +85 500 / 65 J1
6.700 - 7.100 C6771/DA 21 0.30 1.20:1 -25 to +85 500 / 65 J1
6.710 - 7.420 C6774/DA 19 0.50 1.25:1 -25 to +85 500 / 65 J1
7.000 - 7.700 C7077/DA 20 0.50 1.20:1 -25 to +85 500 / 65 J1
7.825 - 8.475 C7884/DA 21 0.40 1.20:1 -25 to +85 500 / 65 J1
8.500 - 9.600 C8596/DA 21 0.30 1.20:1 -25 to +85 500 / 65 J1
Coaxial Circulators
Narrowband Coaxial Circulator Specifications
Broadband Coaxial Circulator SpecificationsModels in bold text are normally in stock for immediate delivery.
FREQUENCY MODEL ISOLATION INS LOSS VSWR OPERATING PWR HANDLING PACKAGE(GHz) NUMBER (dB) MIN (dB) MAX MAX TEMP(˚C) PK/AVG (W) CODE
8.000 - 16.000 C800160/DA 17 0.50 1.35:1 -25 to +85 500 / 65 J1
8.000 - 18.000 C800180/DA 14 0.60 1.50:1 -25 to +85 500 / 65 J1
8.000 - 20.000 C800200/DA 11 1.00 1.78:1 -25 to +85 500 / 50 K1
10.000 - 15.000 C100150/DA 21 0.40 1.20:1 -25 to +85 500 / 65 J1
12.000 - 15.000 C120150/DC 21 0.50 1.20:1 -25 to +85 500 / 65 J1
12.000 - 18.000 C120180/DE 19 0.50 1.25:1 -25 to +85 500 / 65 J1
12.000 - 20.000 C120200/DA 14 0.70 1.50:1 -25 to +85 500 / 65 J1
18.000 - 22.000 C180220/DA 18 0.70 1.30:1 -25 to +85 500 / 65 J1
18.000 - 26.500 C180265/DA 13 1.00 1.58:1 -25 to +85 500 / 50 K1
Page 10
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/0310
Specifications subject to change without notice.
CENTER MODEL BANDWIDTH ISOLATION INS LOSS VSWR OPERATING PWR HANDLING PACKAGEFREQUENCY(GHz) NUMBER (%) (dB MIN) (dB MAX) MAX TEMP (˚C) PK/AVG (W) CODE
0.500 - 0.700 C050070/S*C 5% 19 0.50 1.25:1 0 to +70 1000 / 200 H1
0.700 - 1.000 C070010/S*A 5% 19 0.50 1.25:1 -25 to +85 1000 / 200 H1
1.000 - 1.300 C1013/S*A 10% 20 0.50 1.25:1 -25 to +85 1000 / 200 H1
1.300 - 1.650 C1316/S*A 10% 20 0.50 1.25:1 -25 to +85 1000 / 200 H1
1.300 - 1.650 C1316/S*B 10% 20 0.50 1.25:1 -25 to +85 1000 / 125 I1
1.650 - 2.000 C1620/S*C 10% 20 0.50 1.25:1 -25 to +85 1000 / 125 I1
2.000 - 2.500 C2025/S*C 10% 20 0.50 1.25:1 -25 to +85 500 / 125 I1
2.500 - 3.200 C2532/S*A 10% 20 0.50 1.25:1 -25 to +85 500 / 125 I1
3.000 - 3.800 C3038/S*A 10% 20 0.50 1.25:1 -25 to +85 500 / 125 I1
3.000 - 4.000 C3040/S*A 10% 20 0.50 1.25:1 -25 to +85 500 / 65 J1
3.600 - 5.000 C3650/S*A 10% 20 0.50 1.25:1 -25 to +85 500 / 65 J1
4.800 - 6.000 C4860/S*A 10% 20 0.50 1.25:1 -25 to +85 500 / 65 J1
6.000 - 8.000 C6080/S*A 15% 23 0.50 1.20:1 -25 to +85 500 / 65 J1
8.000 - 15.000 C800150/S*A 10% 23 0.50 1.20:1 -25 to +85 500 / 65 J1
15.000 - 18.000 C150180/S*A 10% 23 0.50 1.20:1 -25 to +85 500 / 65 J1
Coaxial Circulators
Select-A-Frequency Coaxial Circulator SpecificationsRefer to page 50 for Select-A-Frequency Instructions.
FREQUENCY MODEL ISOLATION INS LOSS VSWR OPERATING PWR HANDLING PACKAGE(GHz) NUMBER (dB) MIN (dB) MAX MAX TEMP(˚C) PK/AVG (W) CODE
10.000 - 12.000 C100120/DC 20 0.50 1.25:1 -25 to +85 500 / 65 J1
10.500 - 11.300 C105113/DC 23 0.40 1.15:1 -25 to +85 500 / 65 J1
11.000 - 12.000 C110120/DA 21 0.40 1.20:1 -25 to +85 500 / 65 J1
11.000 - 12.790 C110127/DC 21 0.50 1.20:1 -25 to +85 500 / 65 J1
11.200 - 11.700 C112117/DA 23 0.30 1.15:1 -25 to +85 500 / 65 J1
12.000 - 12.800 C120128/DA 23 0.30 1.15:1 -25 to +85 500 / 65 J1
12.750 - 14.500 C127145/DA 23 0.40 1.15:1 -25 to +85 500 / 65 J1
13.000 - 15.000 C130150/DA 23 0.40 1.15:1 -25 to +85 500 / 65 J1
15.000 - 18.000 C150180/DE 21 0.50 1.20:1 -25 to +85 500 / 65 J1
19.440 - 21.500 C194215/DA 19 0.50 1.25:1 -25 to +85 500 / 65 J1
Narrowband Coaxial Circulator Specifications
Page 11
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/03 11
Specifications subject to change without notice.
DIM = INCH MASS = 7 oz MAX
4X .156 THRU
3
1 2
.75
3X .38
3X .331.60
2X 1.240
2X .18
2X 1.14
1.60
2X 1.240
3X SMA
LCLL
G1 - CIRCULATOR
DIM = INCH MASS = 2.2 oz MAX
H1 - CIRCULATOR
1
3
2
4X .080 THRU
.50
2X .09
2X .820
1.00
2X .69
3X .25
3X .331.00
2X .8202X .09FEMALE CONN3X SMA
CL
DIM = INCH MASS = 2.2 oz MAX
H2 - CIRCULATOR
1
3
2
4X .080 THRU
.50
2X .09
2X .820
1.00
2X .69
3X .25
3X .401.00
2X .8202X .09FEMALE CONN3X SMA
CLCC
Coaxial Circulator Package Drawings
Coaxial Circulators
Page 12
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/0312
Specifications subject to change without notice.
I1 - CIRCULATOR
DIM = INCH MASS = 1.3 oz MAX
3
1 2
3X SMA
2X .080 THRU
FEMALE CONN
.09 .570
.50
3X .25
.75
.75
2X .505
2X .09
3X .33
CLCC
J1 - CIRCULATOR
DIM = INCH MASS = .67 oz MAX
3
1 2
FEMALE3X SMA
2X .075 THRU
2X .06
.380.06
.50 3X .33
2X .33
.503X .25
.50
CONN
LCLL
2X .075 THRU
3X .19
.38
.50
.50 3X .33
2X .06
.380.06
2X .33
3X SMA
LCLL
FEMALE CONN
3
21
DIM = INCH MASS = .6 oz MAX
K1 - CIRCULATOR L1 - CIRCULATOR
DIM = INCH MASS = 4.6 oz MAX
3
1 2
4X .156 THRU
.501.50
2X 1.240
3X .33
2X 1.240
2X .13
1.50
2X 1.09
3X .25
2X .13
LCLL
3X SMAFEMALE
CONN
Coaxial Circulator Package Drawings
Coaxial Circulators
Page 13
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/03 13
Specifications subject to change without notice.
Drop-In Isolators
� Magnetically Shielded
� Military, Space, and Commercial Applications
�Wide Operating Temperature
� Compact, Rugged Construction
� Rich Design Portfolio
� Extensive Program Heritage
Broadband Drop-In Isolator SpecificationsModels in bold text are normally in stock for immediate delivery.
FREQUENCY MODEL ISOLATION INS LOSS VSWR OPERATING PWR HANDLING PACKAGE(GHz) NUMBER (dB) MIN (dB) MAX MAX TEMP(˚C) PK/FWD/REV (W) CODE
0.960 - 1.215 T096012/DB 18 0.50 1.30:1 -25 to +85 1000 / 60 / 1 M1
2.000 - 4.000 T2040/DD 16 0.60 1.40:1 -10 to +70 100 / 40 / 1 C1
2.600 - 5.200 T2652/DD 15 0.60 1.50:1 -25 to +85 100 / 30 / 1 C1
3.000 - 6.000 T3060/DD 16 0.60 1.40:1 -25 to +85 100 / 40 / 1 C1
3.400 - 4.200 T3442/DF 18 0.60 1.30:1 -25 to +85 100 / 60 / 1 E1
4.000 - 8.000 T4080/DI 16 0.60 1.40:1 -25 to +85 100 / 40 / 1 D2
4.700 - 10.000 T470100/DB 12 1.00 1.50:1 -25 to +85 100 / 30 / 1 D2
5.000 - 10.000 T500100/DD 16 0.60 1.40:1 -20 to +70 100 / 40 / 1 D2
6.000 - 18.000 T600180/DD 10 1.50 2.00:1 -25 to +85 100 / 10 / 1 E4
7.400 - 9.400 T7494/DA 19 0.50 1.25:1 -25 to +85 50 / 20 / 0.5 A2
7.500 - 18.000 T750180/DD 12 1.00 1.65:1 -25 to +85 100 / 20 / 1 E3
8.000 - 12.000 T800120/DH 16 0.70 1.45:1 -25 to +85 50 / 20 / 0.5 A1
8.000 - 12.000 T800120/DI 17 0.60 1.40:1 -25 to +85 100 / 40 / 1 E2
8.000 - 12.000 T800120/DJ 16 0.80 1.45:1 -25 to +85 50 / 20 / 0.5 R1
8.000 - 16.000 T800160/DD 14 0.80 1.50:1 -25 to +85 100 / 30 / 1 E2
8.000 - 18.000 T800180/DD 13 1.20 1.60:1 -25 to +85 100 / 20 / 1 E3
12.000 - 18.000 T120180/DI 17 0.90 1.50:1 -25 to +85 50 / 20 / 0.5 A2
12.000 - 18.000 T120180/DJ 17 0.90 1.50:1 -25 to +85 50 / 20 / 0.5 R2
12.000 - 18.000 T120180/DK 17 0.70 1.50:1 -25 to +85 100 / 30 / 1 E3
17.500 - 21.500 T175215/DB 19 0.50 1.25:1 -25 to +85 50 / 20 / 0.5 R2
17.600 - 21.600 T176216/DC 18 0.80 1.35:1 -25 to +85 50 / 20 / 0.5 R2
18.000 - 26.500 T180265/DD 14 1.00 1.50:1 -25 to +85 50 / 20 / 0.5 R2
Page 14
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/0314
Specifications subject to change without notice.
FREQUENCY MODEL ISOLATION INS LOSS VSWR OPERATING PWR HANDLING PACKAGE(GHz) NUMBER (dB) MIN (dB) MAX MAX TEMP(˚C) PK/FWD/REV (W) CODE
0.420 - 0.450 T042045/DD 20 0.50 1.25:1 0 to +50 1000 / 80 / 1 M1
0.980 - 1.080 T098010/DB 21 0.50 1.20:1 -25 to +85 1000 / 120 / 1 F1
1.030 - 1.090 T1010/DC 20 0.50 1.25:1 -25 to +85 1000 / 75 / 1 D1
1.080 - 1.195 T1011/DC 20 0.50 1.25:1 -25 to +85 1000 / 80 / 1 F1
1.200 - 1.400 T1214/DD 18 0.60 1.30:1 -25 to +85 1000 / 60 / 1 F1
1.435 - 1.535 T1415/DD 18 0.50 1.20:1 -25 to +85 1000 / 60 / 1 D1
1.525 - 1.559 T1515/DB 21 0.30 1.20:1 -25 to +85 1000 / 120 / 1 F1
1.960 - 2.170 T1921/DB 17 0.60 1.35:1 -25 to +85 100 / 50 / 1 D1
2.100 - 2.300 T2123/DD 18 0.05 1.30:1 -25 to +85 100 / 60 / 1 D1
2.200 - 2.300 T2223/DD 20 0.50 1.25:1 -25 to +85 1000 / 75 / 1 D1
2.500 - 2.700 T2527/DD 20 0.60 1.25:1 -25 to +85 100 / 75 / 1 D1
2.700 - 2.900 T2729/DB 20 0.60 1.25:1 -25 to +85 100 / 75 / 1 D1
2.800 - 3.300 T2833/DB 15 0.75 1.40:1 -25 to +85 100 / 40 / 1 D1
2.900 - 3.100 T2931/DB 21 0.50 1.20:1 -25 to +85 100 / 75 / 1 D1
3.000 - 3.600 T3036/DB 18 0.50 1.30:1 -25 to +85 100 / 60 / 1 E1
3.400 - 3.700 T3437/DB 20 0.50 1.20:1 -25 to +85 50 / 20 / 0.5 R1
3.600 - 4.200 T3642/DB 19 0.50 1.25:1 -25 to +85 50 / 20 / 0.5 R1
3.700 - 4.200 T3742/DE 20 0.40 1.25:1 -25 to +85 200 / 75 / 1 D1
3.700 - 4.200 T3742/DF 18 0.60 1.30:1 -25 to +85 100 / 60 / 1 E2
3.700 - 4.300 T3743/DA 15 0.60 1.45:1 -25 to +85 50 / 20 / 0.5 A1
4.200 - 4.400 T4244/DE 20 0.50 1.25:1 -25 to +85 50 / 20 / 0.5 A1
4.200 - 4.400 T4244/DF 20 0.40 1.25:1 -25 to +85 200 / 60 / 1 E1
4.200 - 4.400 T4244/DG 20 0.50 1.25:1 -25 to +85 50 / 20 / 0.5 R1
4.400 - 5.000 T4450/DB 21 0.45 1.20:1 -25 to +85 100 / 60 / 1 E1
4.500 - 4.700 T4547/DB 19 0.50 1.25:1 -25 to +85 50 / 20 / 0.5 R1
4.750 - 5.250 T4752/DA 21 0.50 1.20:1 -25 to +85 50 / 20 / 0.5 A1
5.150 - 5.650 T5156/DD 18 0.40 1.30:1 -25 to +85 100 / 60 / 1 E1
5.400 - 5.900 T5459/DE 20 0.50 1.25:1 -25 to +85 200 / 60 / 1 E1
5.400 - 5.900 T5459/DF 21 0.40 1.20:1 -25 to +85 50 / 20 / 0.5 R1
5.845 - 6.425 T5864/DB 21 0.50 1.20:1 -25 to +85 50 / 20 / 0.5 R1
5.900 - 6.400 T5964/DC 19 0.50 1.25:1 -25 to +85 200 / 60 / 1 E1
5.900 - 6.400 T5964/DD 21 0.40 1.20:1 -25 to +85 50 / 20 / 0.5 R1
6.600 - 7.300 T6673/DB 19 0.50 1.25:1 -25 to +85 50 / 20 / 0.5 R1
6.900 - 7.600 T6976/DB 18 0.60 1.30:1 -25 to +85 100 / 60 / 1 D1
7.000 - 7.500 T7075/DB 19 0.50 1.25:1 -25 to +85 100 / 60 / 1 E1
7.000 - 7.700 T7077/DC 21 0.50 1.20:1 -25 to +85 50 / 20 / 0.5 A2
7.100 - 7.700 T7177/DB 20 0.50 1.25:1 -25 to +85 50 / 20 / 0.5 R1
7.125 - 7.875 T7178/DB 18 0.60 1.30:1 -25 to +85 100 / 60 / 1 E1
7.500 - 8.400 T7584/DB 17 0.60 1.35:1 -25 to +85 100 / 50 / 1 E1
7.800 - 8.600 T7886/DB 19 0.50 1.25:1 -25 to +85 50 / 20 / 0.5 R1
8.000 - 8.500 T8085/DC 16 0.60 1.40:1 -25 to +85 100 / 40 / 1 E1
Drop-In Isolators
Narrowband Drop-In Isolator Specifications
Page 15
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/03 15
Specifications subject to change without notice.
FREQUENCY MODEL ISOLATION INS LOSS VSWR OPERATING PWR HANDLING PACKAGE(GHz) NUMBER (dB) MIN (dB) MAX MAX TEMP(˚C) PK/FWD/REV (W) CODE
8.000 - 8.500 T8085/DD 19 0.50 1.25:1 -25 to +85 50 / 20 / 0.7 R1
8.600 - 9.600 T8696/DA 20 0.50 1.20:1 -25 to +85 50 / 20 / 0.5 A2
9.000 - 10.500 T900105/DF 19 0.50 1.25:1 -25 to +85 50 / 20 / 0.5 R2
9.200 - 9.900 T9299/DA 19 0.50 1.25:1 -25 to +85 50 / 20 / 0.5 A2
9.500 - 10.500 T950105/DB 20 0.50 1.25:1 -25 to +85 50 / 20 / 0.5 A2
9.500 - 10.500 T950105/DC 20 0.50 1.25:1 -25 to +85 50 / 20 / 0.5 R2
9.700 - 11.200 T970112/DB 19 0.50 1.25:1 -25 to +85 50 / 20 / 0.5 R2
10.400 - 11.300 T104113/DB 21 0.50 1.20:1 -25 to +85 50 / 20 / 0.5 R2
10.700 - 11.950 T107119/DD 20 0.50 1.25:1 -25 to +85 50 / 20 / 0.5 R2
10.750 - 12.800 T107128/DE 20 0.50 1.25:1 -25 to +85 50 / 20 / 0.5 R2
11.500 - 12.950 T115129/DB 19 0.50 1.25:1 -25 to +85 50 / 20 / 0.5 A2
12.100 - 12.800 T121128/DB 19 0.50 1.25:1 -25 to +85 100 / 60 / 1 E1
12.500 - 14.100 T125141/DB 20 0.50 1.25:1 -25 to +85 50 / 20 / 0.5 R2
12.700 - 13.500 T127135/DB 21 0.50 1.20:1 -25 to +85 50 / 20 / 0.5 R2
12.750 - 14.500 T127145/DC 20 0.70 1.25:1 -25 to +85 50 / 20 / 0.5 R2
12.750 - 14.500 T127145/DD 21 0.50 1.20:1 -25 to +85 50 / 20 / 0.5 R2
17.200 - 17.900 T172179/DD 19 0.50 1.25:1 -25 to +85 50 / 20 / 0.5 R2
17.300 - 18.100 T173181/DB 18 0.60 1.30:1 -25 to +85 50 / 20 / 0.5 R2
19.000 - 20.000 T190200/DB 19 0.50 1.25:1 -25 to +85 50 / 20 / 0.5 R2
19.375 - 19.875 T193198/DB 17 0.60 1.30:1 -25 to +85 50 / 20 / 0.5 R2
19.550 - 20.350 T195203/DC 17 0.60 1.30:1 -25 to +85 50 / 20 / 0.5 A2
22.000 - 22.500 T220225/DB 17 0.60 1.30:1 -25 to +85 50 / 20 / 0.5 R2
22.550 - 24.050 T225240/DB 17 0.60 1.30:1 -25 to +85 50 / 20 / 0.5 R2
22.665 - 23.165 T226231/DB 17 0.60 1.30:1 -25 to +85 50 / 20 / 0.5 R2
Drop-In Isolators
Narrowband Drop-In Isolator Specifications
Page 16
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/0316
Specifications subject to change without notice.
Drop-In Isolators
Select-A-Frequency Drop-In Isolator SpecificationsRefer to page 50 for Select-A-Frequency Instructions.
CENTER MODEL BANDWIDTH ISOLATION INS LOSS VSWR OPERATING PWR HANDLING PACKAGEFREQUENCY(GHz) NUMBER (%) (dB MIN) (dB MAX) MAX TEMP (˚C) PK/FWD/REV (W) CODE
0.500 - 0.700 T050070/S*B 3% 20 0.70 1.25:1 25 to +85 1000 / 80 / 1 F1
0.700 - 1.000 T070010/S*D 5% 20 0.60 1.25:1 -25 to +85 1000 / 80 / 1 F1
1.000 - 1.300 T1013/S*D 10% 20 0.50 1.25:1 -25 to +85 1000 / 80 / 1 F1
1.300 - 1.650 T1316/S*F 10% 20 0.50 1.25:1 -25 to +85 1000 / 80 / 1 F1
1.650 - 2.000 T1620/S*B 5% 20 0.50 1.25:1 -25 to +85 1000 / 75 / 1 D1
2.000 - 2.500 T2025/S*B 5% 20 0.50 1.25:1 -25 to +85 100 / 75 / 1 D1
2.500 - 3.700 T2537/S*B 10% 20 0.60 1.25:1 -25 to +85 100 / 75 / 1 D1
3.700 - 4.600 T3746/S*B 5% 18 0.60 1.30:1 -25 to +85 200 / 60 / 1 E1
4.000 - 8.000 T4080/S*B 10% 20 0.60 1.25:1 -25 to +85 50 / 20 / 0.5 A1
4.000 - 8.000 T4080/S*C 10% 20 0.60 1.25:1 -25 to +85 50 / 20 / 0.5 R1
4.600 - 6.200 T4662/S*B 5% 18 0.60 1.30:1 -25 to +85 200 / 60 / 1 E1
6.200 - 8.000 T6280/S*B 10% 18 0.60 1.30:1 -25 to +85 200 / 60 / 1 E1
8.000 - 10.000 T800100/S*B 10% 18 0.60 1.35:1 -25 to +85 100 / 50 / 1 E1
8.000 - 12.000 T800120/S*B 10% 20 0.60 1.25:1 -25 to +85 50 / 20 / 0.5 A2
8.000 - 12.000 T800120/S*C 10% 20 0.60 1.25:1 -25 to +85 50 / 20 / 0.5 R2
10.000 - 12.000 T100120/S*B 10% 18 0.60 1.35:1 -25 to +85 100 / 50 / 1 E2
12.000 - 15.000 T120150/S*B 10% 18 0.60 1.35:1 -25 to +85 100 / 50 / 1 E2
12.000 - 18.000 T120180/S*B 10% 17 0.80 1.35:1 -25 to +85 50 / 20 / 0.5 A2
15.000 - 18.000 T150180/S*D 10% 17 0.70 1.40:1 -25 to +85 100 / 40 / 1 E3
Page 17
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/03 17
Specifications subject to change without notice.
DIM = INCH MASS = .13 oz MAX
A1 - ISOLATOR
1 2
2X .02
4X .087 THRU2X .05
2X .06
.38
2X .255
2X .34
2X .505
.62.38
.122X .06
2X .07
2X .04
.22
DIM = INCH MASS = .049 oz MAX
A2 - ISOLATOR
1 2
2X .087 THRU
.18
2X .04
2X .07
.50
.380
2X .31
.25
2X .125 2X .05
.06
2X .02
DIM = INCH MASS = .99 oz MAX
C1 - ISOLATOR
1
3
4X .080 THRU
.87
.87
2X .750 2X .62
2X .15
2X .02
2X .06
.19
.20
2
2X .07
2X .7502X .06
CLCC
TERMINATION
Drop-In Isolator Package Drawings
DIM = INCH MASS = .56 oz MAX
D - ISOLATOR D2D1
3
1 2
4X .078 THRU
.26
2X .102X .12
.26
.19
.75
2X .570
.75 2X .570
2X .50
2X .09
2X .07
2X .09
.20.20
.19
CLCC
TERMINATION
Drop-In Isolators
Tab leads are .005” +/- .001 thick beryllium copper, silver plated or solder tinned (gold plating optional).
Page 18
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/0318
Specifications subject to change without notice.
Drop-In Isolator Package Drawings
Drop-In Isolators
DIM = INCH MASS = 1.2 oz MAX
F1 - ISOLATOR
1
3
4X .080 THRU
2X .8201.00
2X .69
2X .820
1.00 2X .07
2X .09
2X .09
.20
2X .02
2X .15
.30
.19
2
TERMINATION
CLCC
DIM = INCH MASS = 4.6 oz MAX
M1 - ISOLATOR
3
1
4X .156 THRU
2
.50
2X .25
.25
1.50
2X 1.2402X .13
2X .07
2X 1.09
2X .02
2X 1.240
1.50
2X .13
TERMINATION CLCC
.20
DIM = INCH MASS = .035 oz MAX
R2 - ISOLATOR
1
.25
.17
2X .18
.25
2X .025
2X .07
2
2X .05
DIM = INCH MASS = .11 oz MAX
R1 - ISOLATOR
.22
.37
2X .07
1 2
2X .28
2X .05 .37
2X .025
DIM = INCH MASS = .25 oz MAX
E - ISOLATOR E4E3E2E1
2
3
1
4X .075 THRU .19
2X .12
.25
2X .09
.25
2X .08
.25
2X .06
.20
2X .380
2X .06
2X .07.50
2X .02
.50
2X .33
2X .06 2X .380
.20
.19
.20
.19
.20
.19
.20
CLCCTERMINATION
Tab leads are .005” +/- .001 thick beryllium copper, silver plated or solder tinned (gold plating optional).
Page 19
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/03 19
Specifications subject to change without notice.
Drop-In Circulators
Broadband Drop-In Circulator SpecificationsModels in bold text are normally in stock for immediate delivery.
� Magnetically Shielded
� Military, Space, and Commercial Applications
�Wide Operating Temperature
� Compact, Rugged Construction
� Rich Design Portfolio
� Extensive Program Heritage
FREQUENCY MODEL ISOLATION INS LOSS VSWR OPERATING PWR HANDLING PACKAGE(GHz) NUMBER (dB) MIN (dB) MAX MAX TEMP(˚C) PK/AVG (W) CODE
0.960 - 1.215 C096012/DA 19 0.50 1.30:1 -25 to +85 1000 / 200 M1
2.000 - 4.000 C2040/DC 16 0.60 1.40:1 -10 to +70 100 / 100 C1
2.600 - 5.200 C2652/DC 15 0.60 1.50:1 -25 to +85 100 / 100 C1
3.000 - 6.000 C3060/DC 16 0.60 1.40:1 -25 to +85 100 / 75 C1
3.400 - 4.200 C3442/DE 18 0.60 1.30:1 -25 to +85 100 / 65 E1
4.000 - 8.000 C4080/DH 16 0.60 1.40:1 -25 to +85 100 / 75 D2
4.200 - 5.200 C4252/DA 18 0.50 1.30:1 -25 to +85 15 / 15 R3
4.700 - 10.000 C470100/DA 12 1.00 1.65:1 -25 to +85 100 / 75 D2
5.000 - 10.000 C500100/DC 15 0.60 1.45:1 -20 to +70 100 / 75 D2
6.000 - 18.000 C600180/DC 10 1.50 2.00:1 -25 to +85 100 / 65 E4
7.500 - 18.000 C750180/DC 12 1.00 1.65:1 -40 to +80 100 / 20 E3
8.000 - 12.000 C800120/DF 16 0.60 1.40:1 -25 to +85 100 / 75 E2
8.000 - 12.000 C800120/DG 16 0.70 1.45:1 -25 to +85 50 / 20 R1
8.000 - 16.000 C800160/DC 14 0.80 1.50:1 -25 to +85 100 / 65 E2
8.000 - 18.000 C800180/DC 13 1.20 1.60:1 -25 to +85 100 / 20 E3
12.000 - 18.000 C120180/DG 17 1.00 1.50:1 -25 to +85 50 / 20 R2
12.000 - 18.000 C120180/DH 15 0.70 1.50:1 -25 to +85 100 / 50 E3
17.500 - 21.500 C175215/DA 19 0.50 1.25:1 -25 to +85 50 / 20 R2
18.000 - 26.500 C180265/DC 14 1.00 1.50:1 -25 to +85 50 / 20 R4
Page 20
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/0320
Specifications subject to change without notice.
Drop-In Circulators
FREQUENCY MODEL ISOLATION INS LOSS VSWR OPERATING PWR HANDLING PACKAGE(GHz) NUMBER (dB) MIN (dB) MAX MAX TEMP(˚C) PK/AVG (W) CODE
0.420 - 0.450 C042045/DC 20 0.50 1.30:1 0 to +50 1000 / 300 M1
0.980 - 1.080 C098010/DA 21 0.50 1.20:1 -25 to +85 1000 / 300 F1
1.030 - 1.090 C1010/DB 20 0.50 1.25:1 -25 to +85 1000 / 100 D1
1.080 - 1.195 C1011/DB 20 0.50 1.25:1 -25 to +85 1000 / 300 F1
1.200 - 1.400 C1214/DC 17 0.60 1.35:1 -25 to +85 1000 / 300 F1
1.435 - 1.535 C1415/DC 18 0.50 1.20:1 -25 to +85 1000 / 100 D1
1.525 - 1.559 C1515/DA 21 0.30 1.20:1 -25 to +85 1000 / 300 F1
1.960 - 2.170 C1921/DA 17 0.60 1.35:1 -25 to +85 100 / 75 D1
2.100 - 2.300 C2123/DC 18 0.05 1.30:1 -25 to +85 100 / 75 D1
2.200 - 2.300 C2223/DC 20 0.50 1.25:1 -25 to +85 1000 / 100 D1
2.500 - 2.700 C2527/DC 18 0.50 1.30:1 -25 to +85 100 / 65 D1
2.700 - 2.900 C2729/DA 20 0.40 1.25:1 -25 to +85 100 / 75 D1
2.800 - 3.300 C2833/DA 15 0.75 1.40:1 -25 to +85 100 / 75 D1
2.900 - 3.100 C2931/DA 21 0.50 1.20:1 -25 to +85 100 / 75 D1
3.000 - 3.600 C3036/DA 18 0.60 1.30:1 -25 to +85 100 / 65 E1
3.400 - 3.700 C3437/DA 20 0.50 1.20:1 -25 to +85 50 / 20 R1
3.600 - 4.200 C3642/DA 19 0.50 1.25:1 -25 to +85 50 / 20 R1
3.700 - 4.200 C3742/DC 20 0.40 1.25:1 -25 to +85 200 / 75 D1
3.700 - 4.200 C3742/DD 18 0.60 1.30:1 -25 to +85 100 / 65 E2
4.200 - 4.400 C4244/DC 18 0.40 1.30:1 -25 to +85 200 / 65 E1
4.200 - 4.400 C4244/DD 20 0.50 1.25:1 -25 to +85 50 / 20 R1
4.400 - 5.000 C4450/DA 21 0.45 1.20:1 -25 to +85 100 / 65 E1
4.500 - 4.700 C4547/DA 19 0.50 1.25:1 -25 to +85 50 / 20 R1
5.150 - 5.650 C5156/DC 18 0.40 1.30:1 -25 to +85 100 / 65 E1
5.400 - 5.900 C5459/DC 18 0.50 1.30:1 -25 to +85 200 / 65 E1
5.400 - 5.900 C5459/DD 21 0.40 1.20:1 -25 to +85 50 / 20 R1
5.845 - 6.425 C5864/DA 21 0.50 1.20:1 -25 to +85 50 / 20 R1
5.900 - 6.400 C5964/DA 19 0.50 1.25:1 -25 to +85 200 / 65 E1
5.900 - 6.400 C5964/DB 21 0.40 1.20:1 -25 to +85 50 / 20 R1
6.600 - 7.300 C6673/DA 19 0.50 1.25:1 -25 to +85 50 / 20 R1
6.900 - 7.600 C6976/DA 18 0.60 1.30:1 -25 to +85 100 / 75 D1
7.000 - 7.500 C7075/DA 19 0.50 1.25:1 -25 to +85 100 / 65 E1
7.100 - 7.700 C7177/DA 20 0.50 1.25:1 -25 to +85 50 / 20 R1
7.125 - 7.875 C7178/DA 18 0.60 1.30:1 -25 to +85 100 / 65 E1
7.500 - 8.400 C7584/DA 17 0.60 1.35:1 -25 to +85 100 / 65 E1
7.800 - 8.600 C7886/DA 19 0.50 1.25:1 -25 to +85 50 / 20 R1
8.000 - 8.500 C8085/DA 16 0.60 1.40:1 -25 to +85 100 / 65 E1
8.000 - 8.500 C8085/DB 19 0.50 1.25:1 -25 to +85 50 / 20 R1
9.000 - 10.500 C900105/DE 19 0.50 1.25:1 -25 to +85 50 / 20 R2
9.500 - 10.500 C950105/DA 20 0.50 1.25:1 -25 to +85 50 / 20 R2
9.700 - 11.200 C970112/DA 19 0.50 1.25:1 -25 to +85 50 / 20 R2
10.400 - 11.300 C104113/DA 21 0.50 1.20:1 -25 to +85 50 / 20 R2
Narrowband Drop-In Circulator Specifications
Page 21
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/03 21
Specifications subject to change without notice.
Drop-In Circulators
CENTER MODEL BANDWIDTH ISOLATION INS LOSS VSWR OPERATING PWR HANDLING PACKAGEFREQUENCY(GHz) NUMBER (%) (dB MIN) (dB MAX) MAX TEMP (˚C) PK/AVG (W) CODE
0.500 - 0.700 C050070/S*A 3% 20 0.70 1.25:1 -25 to +85 1000 / 300 F1
0.700 - 1.000 C070010/S*C 5% 20 0.60 1.25:1 -25 to +85 1000 / 300 F1
1.000 - 1.300 C1013/S*C 10% 20 0.50 1.25:1 -25 to +85 1000 / 300 F1
1.300 - 1.650 C1316/S*E 10% 20 0.50 1.25:1 -25 to +85 1000 / 300 F1
1.650 - 2.000 C1620/S*A 5% 20 0.50 1.25:1 -25 to +85 1000 / 100 D1
2.000 - 2.500 C2025/S*A 5% 20 0.50 1.25:1 -25 to +85 1000 / 100 D1
2.500 - 3.700 C2537/S*A 10% 20 0.60 1.25:1 -25 to +85 100 / 75 D1
3.700 - 4.600 C3746/S*A 5% 18 0.60 1.30:1 -25 to +85 100 / 65 E1
4.000 - 8.000 C4080/S*A 10% 20 0.60 1.25:1 -25 to +85 50 / 20 R1
4.600 - 6.200 C4662/S*A 5% 18 0.60 1.30:1 -25 to +85 200 / 65 E1
6.200 - 8.000 C6280/S*A 10% 18 0.60 1.30:1 -25 to +85 200 / 65 E1
8.000 - 10.000 C800100/S*A 10% 18 0.60 1.35:1 -25 to +85 100 / 65 E1
8.000 - 12.000 C800120/S*A 10% 20 0.60 1.25:1 -25 to +85 50 / 20 R2
10.000 - 12.000 C100120/S*A 10% 18 0.60 1.35:1 -25 to +85 100 / 65 E2
12.000 - 15.000 C120150/S*A 10% 18 0.60 1.35:1 -25 to +85 100 / 65 E2
12.000 - 18.000 C120180/S*A 10% 17 0.80 1.35:1 -25 to +85 50 / 20 R2
15.000 - 18.000 C150180/S*C 10% 17 0.60 1.40:1 -25 to +85 100 / 65 E3
Select-A-Frequency Drop-In Circulator SpecificationsRefer to page 50 for Select-A-Frequency Instructions.
FREQUENCY MODEL ISOLATION INS LOSS VSWR OPERATING PWR HANDLING PACKAGE(GHz) NUMBER (dB) MIN (dB) MAX MAX TEMP(˚C) PK/AVG (W) CODE
10.700 - 11.950 C107119/DC 20 0.50 1.25:1 -25 to +85 50 / 20 R2
10.750 - 12.800 C107128/DD 20 0.50 1.25:1 -25 to +85 50 / 20 R2
12.100 - 12.800 C121128/DA 19 0.50 1.25:1 -25 to +85 100 / 65 E1
12.500 - 14.100 C125141/DA 20 0.50 1.25:1 -25 to +85 50 / 20 R2
12.700 - 13.500 C127135/DA 21 0.50 1.20:1 -25 to +85 50 / 20 R2
17.200 - 17.900 C172179/DC 19 0.50 1.25:1 -25 to +85 50 / 20 R2
17.300 - 18.100 C173181/DA 18 0.60 1.30:1 -25 to +85 50 / 20 R2
19.000 - 20.000 C190200/DA 19 0.50 1.25:1 -25 to +85 50 / 20 R2
19.375 - 19.875 C193198/DA 17 0.60 1.30:1 -25 to +85 50 / 20 R2
22.000 - 22.500 C220225/DA 17 0.60 1.30:1 -25 to +85 50 / 20 R2
22.550 - 24.050 C225240/DA 17 0.60 1.30:1 -25 to +85 50 / 20 R2
22.660 - 23.165 C226231/DA 17 0.60 1.30:1 -25 to +85 50 / 20 R2
Narrowband Drop-In Circulator Specifications
Page 22
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/0322
Specifications subject to change without notice.
Drop-In Circulators
Drop-In Circulator Package Drawings
DIM = INCH MASS = .56 oz MAX
D1D - CIRCULATOR D2
3
1 2
4X .078 THRU
3X .10
.26
3X .12
.26.75
2X .570
2X .50
3X .07
2X .09
2X .570
2X .09
3X .02
.37
.75
E - CIRCULATOR E1 E2 E3 E4
DIM = INCH MASS = .25 oz MAX
2
3
1
4X .075 THRU
.50 3X .07
2X .3802X .06
3X .02
.50
2X .33
2X .380
2X .06.25
3X .12
.25 .25
3X .09 3X .08
.25 .20
3X .06
Tab leads are .005” +/- .001 thick beryllium copper, silver plated or solder tinned (gold plating optional).
DIM = INCH MASS = .99 oz MAX
C1 - CIRCULATOR
4X .080 THRU
.35
3
2
.87
.87
.43
2X .622X .750
3X .07
3X .02
3X .15
2X .06
1
2X .06 2X .750
DIM = INCH MASS = 1.2 oz MAX
F1 - CIRCULATOR
1
3
4X .080 THRU
2
3X .15
.303X .07
2X .09
3X .02
1.00
2X .820
2X .09
2X .692X .820
1.00
.50
Page 23
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/03 23
Specifications subject to change without notice.
Drop-In Circulator Package Drawings
Drop-In Circulators
DIM = INCH MASS = .035 oz MAX
R2 - CIRCULATOR
1
.25
.17
2X .18
.25
3X .025
3X .05 3X .07
2
.12
3
DIM = INCH MASS = .053 oz MAX
R3 - CIRCULATOR
.20
2X .28
3X .025
.38
3X .05 3X .05.38
.19
21
3
DIM = INCH MASS = .035 oz MAX
R4 - CIRCULATOR
2X .18
.25
.25
3X .05
3X .025
3X .12
.25
.12
21
3
DIM = INCH MASS = .11 oz MAX
R1 - CIRCULATOR
1 2
.22
.37
3X .073X .05 .37
3X .025
3
.18
2X .28
DIM = INCH MASS = 4.6 oz MAX
M1 - CIRCULATOR
3
1
4X .156 THRU
2
.50
3X .25
2X 1.09
3X .02
3X .07
2X .13
1.50
2X 1.240
2X .13
2X 1.240
1.50
.75
Tab leads are .005” +/- .001 thick beryllium copper, silver plated or solder tinned (gold plating optional).
Page 24
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/0324
Specifications subject to change without notice.
FREQUENCY MODEL ISOLATION INS LOSS VSWR OPERATING PWR HANDLING PACKAGE(GHz) NUMBER (dB) MIN (dB) MAX MAX TEMP(˚C) PK/FWD/REV (W) CODE
3.400 - 4.200 T3442/DH 17 0.60 1.30:1 -25 to +85 100 / 75 / 1 T3
10.500 - 13.000 T105130/DB 18 0.50 1.30:1 -25 to +85 50 / 20 / 0.5 T2
MICpuck™ Isolators
� Low Profile
� Low Mass
� Magnetically Shielded
� Alumina Substrate
� Military, Space, and Commercial Applications
�Wide Operating Temperature
� Compact, Rugged Construction
� Rich Design Portfolio
� Extensive Program Heritage
Broadband MICpuck™ Isolator Specifications
FREQUENCY MODEL ISOLATION INS LOSS VSWR OPERATING PWR HANDLING PACKAGE(GHz) NUMBER (dB) MIN (dB) MAX MAX TEMP(˚C) PK/FWD/REV (W) CODE
1.000 - 1.050 T1010/DB 19 0.50 1.25:1 -25 to +85 75 / 50 / 1 T4
1.525 - 1.559 T1515/DD 20 0.50 1.20:1 -25 to +85 75 / 50 / 1 T4
2.020 - 2.190 T2021/DB 20 0.40 1.22:1 -25 to +85 75 / 50 / 1 T4
2.100 - 2.300 T2123/DF 20 0.50 1.25:1 -25 to +85 75 / 50 / 1 T4
2.300 - 2.500 T2325/DB 20 0.50 1.25:1 -25 to +85 75 / 50 / 1 T3
2.400 - 2.800 T2428/DB 20 0.50 1.25:1 -25 to +85 75 / 50 / 1 T3
2.500 - 2.900 T2529/DB 20 0.50 1.25:1 -25 to +85 75 / 50 / 1 T3
2.700 - 2.950 T2729/DD 20 0.50 1.25:1 -25 to +85 75 / 50 / 1 T3
2.900 - 3.300 T2933/DB 20 0.50 1.25:1 -25 to +85 75 / 50 / 1 T3
3.100 - 3.300 T3133/DB 20 0.50 1.25:1 -25 to +85 100 / 75 / 1 T3
3.400 - 3.800 T3438/DB 20 0.50 1.25:1 -25 to +85 100 / 75 / 1 T3
3.500 - 3.700 T3537/DB 20 0.50 1.25:1 -25 to +85 100 / 75 / 1 T3
3.600 - 4.200 T3642/DD 21 0.50 1.20:1 -25 to +85 100 / 75 / 1 T1
4.300 - 4.500 T4345/DB 21 0.50 1.20:1 -25 to +85 50 / 20 / 0.7 T1
4.400 - 4.800 T4448/DB 21 0.50 1.20:1 -25 to +85 50 / 20 / 0.7 T1
4.700 - 4.900 T4749/DB 20 0.50 1.25:1 -25 to +85 50 / 20 / 0.7 T1
5.400 - 5.900 T5459/DH 20 0.50 1.25:1 -25 to +85 50 / 20 / 0.7 T1
5.850 - 6.450 T5864/DE 20 0.50 1.25:1 -25 to +85 50 / 20 / 0.7 T1
5.900 - 6.200 T5962/DB 21 0.50 1.20:1 -25 to +85 50 / 20 / 0.7 T1
6.400 - 6.700 T6467/DB 20 0.50 1.25:1 -25 to +85 50 / 20 / 0.7 T1
6.650 - 7.350 T6673/DD 20 0.50 1.25:1 -25 to +85 50 / 20 / 0.7 T1
Narrowband MICpuck™ Isolator Specifications
Page 25
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/03 25
Specifications subject to change without notice.
FREQUENCY MODEL ISOLATION INS LOSS VSWR OPERATING PWR HANDLING PACKAGE(GHz) NUMBER (dB) MIN (dB) MAX MAX TEMP(˚C) PK/FWD/REV (W) CODE
6.700 - 7.100 T6771/DD 18 0.60 1.20:1 -25 to +85 50 / 20 / 0.7 T1
7.100 - 7.300 T7173/DB 19 0.50 1.25:1 -25 to +85 50 / 20 / 0.7 T1
7.125 - 7.875 T7178/DD 18 0.50 1.30:1 -25 to +85 50 / 20 / 0.7 T1
7.200 - 7.400 T7274/DB 19 0.50 1.25:1 -25 to +85 50 / 20 / 0.7 T1
7.250 - 7.750 T7277/DB 18 0.50 1.30:1 -25 to +85 50 / 20 / 0.7 T1
7.400 - 7.600 T7476/DB 19 0.50 1.25:1 -25 to +85 50 / 20 / 0.7 T1
7.550 - 8.050 T7580/DB 19 0.50 1.25:1 -25 to +85 50 / 20 / 0.7 T1
7.825 - 8.475 T7884/DD 21 0.50 1.20:1 -25 to +85 50 / 20 / 0.5 T2
7.825 - 8.475 T7884/DF 21 0.50 1.20:1 -25 to +85 50 / 20 / 0.5 T2
8.050 - 8.250 T8082/DB 19 0.50 1.25:1 -25 to +85 50 / 20 / 0.7 T1
8.550 - 9.450 T8594/DB 18 0.60 1.30:1 -25 to +85 50 / 20 / 0.5 T2
9.400 - 9.900 T9499/DB 19 0.50 1.25:1 -25 to +85 50 / 20 / 0.5 T2
9.800 - 10.800 T980108/DB 18 0.60 1.30:1 -25 to +85 50 / 20 / 0.5 T2
10.700 - 11.700 T107117/DB 21 0.50 1.20:1 -25 to +85 50 / 20 / 0.5 T2
10.700 - 12.750 T107127/DB 20 0.50 1.20:1 -25 to +85 50 / 20 / 0.5 T2
11.000 - 13.000 T110130/DB 18 0.60 1.30:1 -25 to +85 50 / 20 / 0.5 T2
11.400 - 11.700 T114117/DC 20 0.50 1.25:1 -25 to +85 50 / 20 / 0.5 T2
11.700 - 12.700 T117127/DD 21 0.50 1.20:1 -25 to +85 50 / 20 / 0.5 T2
12.700 - 13.800 T127138/DD 21 0.50 1.20:1 -25 to +85 50 / 20 / 0.5 T2
13.100 - 14.700 T131147/DB 18 0.60 1.30:1 -25 to +85 50 / 20 / 0.5 T2
13.400 - 15.000 T134150/DB 18 0.60 1.30:1 -25 to +85 50 / 20 / 0.5 T2
14.000 - 14.500 T140145/DB 21 0.50 1.20:1 -25 to +85 50 / 20 / 0.5 T2
17.100 - 17.900 T171179/DB 17 0.80 1.40:1 -25 to +85 50 / 20 / 0.5 T2
17.300 - 18.500 T173185/DF 21 0.50 1.20:1 -25 to +85 50 / 20 / 0.5 T2
17.800 - 19.000 T178190/DB 21 0.50 1.20:1 -25 to +85 50 / 20 / 0.5 T2
18.100 - 19.100 T181191/DB 19 0.60 1.25:1 -25 to +85 50 / 20 / 0.5 T2
18.800 - 20.200 T188202/DB 20 0.60 1.20:1 -25 to +85 50 / 20 / 0.5 T2
19.500 - 20.500 T195205/DB 19 0.50 1.25:1 -25 to +85 50 / 20 / 0.5 T2
20.000 - 20.600 T200206/DB 21 0.60 1.20:1 -25 to +85 50 / 20 / 0.5 T2
20.200 - 21.200 T202212/DB 21 0.60 1.20:1 -25 to +85 50 / 20 / 0.5 T2
21.000 - 23.000 T210230/DB 19 0.60 1.25:1 -25 to +85 50 / 20 / 0.5 T2
MICpuck™ Isolators
Narrowband MICpuck™ Isolator Specifications
CENTER MODEL BANDWIDTH ISOLATION INS LOSS VSWR OPERATING PWR HANDLING PACKAGEFREQUENCY(GHz) NUMBER (%) (dB MIN) (dB MAX) MAX TEMP (˚C) PK/FWD/REV (W) CODE
4.000 - 8.000 T4080/S*E 10% 19 0.55 1.30:1 -25 to +85 50 / 20 / 0.7 T1
8.000 - 12.000 T800120/S*E 10% 19 0.70 1.25:1 -25 to +85 50 / 20 / 0.5 T2
12.000 - 18.000 T120180/S*D 10% 17 0.80 1.35:1 -25 to +85 50 / 20 / 0.5 T2
Select-A-Frequency MICpuck™ Isolator SpecificationsRefer to page 50 for Select-A-Frequency Instructions.
Page 26
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/0326
Specifications subject to change without notice.
DIM = INCH MASS = .14 oz MAX
T1 - ISOLATOR
4X .073 THRU
2X .06
.04
2X .06
2X .025
2X .06
.40.62
2X .42
.25 MAX
2X .380
.50
2X .500
21
T2 - ISOLATOR
DIM = INCH MASS = .056 oz MAX
4X .073 THRU
1 2
.04
2X .06
.27
2X .015
2X .380
2X .06
2X .31
.50
2X .230
.35
2X .06
.15 MAX
T3 - ISOLATOR
DIM = INCH MASS = .58 oz MAX
4X .090 THRU
21
3
.87
.32 MAX
.06
1.15
2X .950
2X .79
2X .950
1.15
2X .09
2X .09
2X .025
T4 - ISOLATOR
DIM = INCH MASS = .46 oz MAX
4X .080 THRU
1 2
3
1.00 .30 MAX
.042X .820
2X .09
1.00 2X .820
2X .70
.75
2X .09
2X .050
MICpuck™ Isolator Package Drawings
MICpuck™ Isolators
Page 27
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/03 27
Specifications subject to change without notice.
FREQUENCY MODEL ISOLATION INS LOSS VSWR OPERATING PWR HANDLING PACKAGE(GHz) NUMBER (dB) MIN (dB) MAX MAX TEMP(˚C) PK/AVG (W) CODE
3.400 - 4.200 C3442/DG 17 0.60 1.30:1 -25 to +85 100 / 75 T3
10.500 - 13.000 C105130/DA 18 0.50 1.30:1 -25 to +85 50 / 20 T2
MICpuck™ Circulator
Broadband MICpuck™ Circulator Specifications
FREQUENCY MODEL ISOLATION INS LOSS VSWR OPERATING PWR HANDLING PACKAGE(GHz) NUMBER (dB) MIN (dB) MAX MAX TEMP(˚C) PK/AVG (W) CODE
1.000 - 1.050 C1010/DA 19 0.50 1.25:1 -25 to +85 75 / 50 T4
1.525 - 1.559 C1515/DC 20 0.50 1.25:1 -25 to +85 75 / 50 T4
2.020 - 2.190 C2021/DA 20 0.40 1.22:1 -25 to +85 75 / 50 T4
2.100 - 2.300 C2123/DE 20 0.50 1.25:1 -25 to +85 75 / 50 T4
2.300 - 2.500 C2325/DA 20 0.50 1.25:1 -25 to +85 75 / 50 T3
2.400 - 2.800 C2428/DA 20 0.50 1.25:1 -25 to +85 75 / 50 T3
2.500 - 2.900 C2529/DA 20 0.50 1.25:1 -25 to +85 75 / 50 T3
2.700 - 2.950 C2729/DC 20 0.50 1.25:1 -25 to +85 75 / 50 T3
2.900 - 3.300 C2933/DA 20 0.50 1.25:1 -25 to +85 75 / 50 T3
3.100 - 3.300 C3133/DA 20 0.50 1.25:1 -25 to +85 50 / 20 T3
3.400 - 3.800 C3438/DA 20 0.50 1.25:1 -25 to +85 50 / 20 T3
3.500 - 3.700 C3537/DA 20 0.50 1.25:1 -25 to +85 50 / 20 T3
3.600 - 4.200 C3642/DC 21 0.50 1.20:1 -25 to +85 50 / 20 T1
4.300 - 4.500 C4345/DA 21 0.50 1.20:1 -25 to +85 50 / 20 T1
4.400 - 4.800 C4448/DA 21 0.50 1.20:1 -25 to +85 50 / 20 T1
4.700 - 4.900 C4749/DA 20 0.50 1.20:1 -25 to +85 50 / 20 T1
5.400 - 5.900 C5459/DG 20 0.50 1.20:1 -25 to +85 50 / 20 T1
5.850 - 6.450 C5864/DD 20 0.50 1.20:1 -25 to +85 50 / 20 T1
5.900 - 6.200 C5962/DA 21 0.50 1.20:1 -25 to +85 50 / 20 T1
6.400 - 6.700 C6467/DA 20 0.50 1.20:1 -25 to +85 50 / 20 T1
6.650 - 7.350 C6673/DC 20 0.50 1.20:1 -25 to +85 50 / 20 T1
Narrowband MICpuck™ Circulator Specifications
� Low Profile
� Low Mass
� Magnetically Shielded
� Alumina Substrate
� Military, Space, and Commercial Applications
�Wide Operating Temperature
� Compact, Rugged Construction
� Rich Design Portfolio
� Extensive Program Heritage
Page 28
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/0328
Specifications subject to change without notice.
MICpuck™ Circulators
CENTER MODEL BANDWIDTH ISOLATION INS LOSS VSWR OPERATING PWR HANDLING PACKAGEFREQUENCY(GHz) NUMBER (%) (dB MIN) (dB MAX) MAX TEMP (˚C) PK/AVG (W) CODE
4.000 - 8.000 C4080/S*D 10% 19 0.70 1.30:1 -25 to +85 50 / 20 T1
8.000 - 12.000 C800120/S*D 10% 17 0.70 1.25:1 -25 to +85 50 / 20 T2
12.000 - 18.000 C120180/S*C 10% 17 0.80 1.35:1 -25 to +85 50 / 20 T2
Select-A-Frequency MICpuck™ Circulator SpecificationsRefer to page 50 for Select-A-Frequency Instructions.
FREQUENCY MODEL ISOLATION INS LOSS VSWR OPERATING PWR HANDLING PACKAGE(GHz) NUMBER (dB) MIN (dB) MAX MAX TEMP(˚C) PK/AVG (W) CODE
6.700 - 7.100 C6771/DC 18 0.60 1.20:1 -25 to +85 50 / 20 T1
7.100 - 7.300 C7173/DA 19 0.50 1.20:1 -25 to +85 50 / 20 T1
7.125 - 7.875 C7178/DC 18 0.50 1.20:1 -25 to +85 50 / 20 T1
7.200 - 7.400 C7274/DA 19 0.50 1.20:1 -25 to +85 50 / 20 T1
7.250 - 7.750 C7277/DA 18 0.50 1.20:1 -25 to +85 50 / 20 T1
7.400 - 7.600 C7476/DA 19 0.50 1.20:1 -25 to +85 50 / 20 T1
7.550 - 8.050 C7580/DA 19 0.50 1.20:1 -25 to +85 50 / 20 T1
7.825 - 8.475 C7884/DC 21 0.50 1.20:1 -25 to +85 50 / 20 T2
7.825 - 8.475 C7884/DE 21 0.50 1.20:1 -25 to +85 50 / 20 T2
8.050 - 8.250 C8082/DA 19 0.50 1.20:1 -25 to +85 50 / 20 T1
8.550 - 9.450 C8594/DA 18 0.60 1.30:1 -25 to +85 50 / 20 T2
9.400 - 9.900 C9499/DA 19 0.50 1.25:1 -25 to +85 50 / 20 T2
9.800 - 10.800 C980108/DA 18 0.60 1.30:1 -25 to +85 50 / 20 T2
10.700 - 11.700 C107117/DA 21 0.50 1.20:1 -25 to +85 50 / 20 T2
10.700 - 12.750 C107127/DA 20 0.50 1.20:1 -25 to +85 50 / 20 T2
11.000 - 13.000 C110130/DA 18 0.60 1.30:1 -25 to +85 50 / 20 T2
11.400 - 11.700 C114117/DB 20 0.50 1.25:1 -25 to +85 50 / 20 T2
11.700 - 12.700 C117127/DC 21 0.50 1.20:1 -25 to +85 50 / 20 T2
12.700 - 13.800 C127138/DC 21 0.50 1.20:1 -25 to +85 50 / 20 T2
13.100 - 14.700 C131147/DA 18 0.60 1.30:1 -25 to +85 50 / 20 T2
13.400 - 15.000 C134150/DA 18 0.60 1.30:1 -25 to +85 50 / 20 T2
14.000 - 14.500 C140145/DA 21 0.50 1.20:1 -25 to +85 50 / 20 T2
17.100 - 17.900 C171179/DA 17 0.80 1.40:1 -25 to +85 50 / 20 T2
17.300 - 18.500 C173185/DE 21 0.50 1.20:1 -25 to +85 50 / 20 T2
17.800 - 19.000 C178190/DA 21 0.50 1.20:1 -25 to +85 50 / 20 T2
18.100 - 19.100 C181191/DA 19 0.60 1.25:1 -25 to +85 50 / 20 T2
18.800 - 20.200 C188202/DA 20 0.60 1.20:1 -25 to +85 50 / 20 T2
19.500 - 20.500 C195205/DA 19 0.50 1.25:1 -25 to +85 50 / 20 T2
20.000 - 20.600 C200206/DA 21 0.60 1.20:1 -25 to +85 50 / 20 T2
20.200 - 21.200 C202212/DA 21 0.60 1.20:1 -25 to +85 50 / 20 T2
21.000 - 23.000 C210230/DA 19 0.60 1.25:1 -25 to +85 50 / 20 T2
Narrowband MICpuck™ Circulator Specifications
Page 29
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/03 29
Specifications subject to change without notice.
T1 - CIRCULATOR
DIM = INCH MASS = .14 oz MAX
4X .073 THRU
1 2
32X .42
.62
2X .380
.50
2X .500 .40
.04
3X .06
.25 MAX
2X .06
3X .025
2X .06
CLCC
T2 - CIRCULATOR
DIM = INCH MASS = .056 oz MAX
4X .073 THRU
3X .06
2X .06 .04
.15 MAX
3X .015
.35
.50
2X .31
2X .230
2X .380
.27
1 2
3
CLCC
2X .06
T3 - CIRCULATOR
DIM = INCH MASS = .58 oz MAX
4X .090 THRU
1 2
3
1.15
2X .950 .06
.32 MAX
2X .950
1.15
2X .79
.87
CLCC
2X .09
2X .09
3X .025
T4 - CIRCULATOR
DIM = INCH MASS = .46 oz MAX
4X .080 THRU
2X .09
.30 MAX
.04
2X .09
1.00
2X .820
1.00
2X .820
2X .70
.75
1
3
2
CLCC
3X .050
MICpuck™ Circulators Package Drawings
MICpuck™ Circulators
Page 30
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/0330
Specifications subject to change without notice.
Microstrip Isolators
� Low Profile
� Low Mass
� Ideal for Phased Arrays
� Space Qualified for Hybrid and MIC Modules
� Military, Space, and Commercial Applications
�Wide Operating Temperature
� Compact, Rugged Construction
� Rich Design Portfolio
� Extensive Program Heritage
Broadband Microstrip Isolator SpecificationsModels in bold text are normally in stock for immediate delivery.
FREQUENCY MODEL ISOLATION INS LOSS VSWR OPERATING PWR HANDLING PACKAGE(GHz) NUMBER (dB) MIN (dB) MAX MAX TEMP(˚C) PK/FWD/REV (W) CODE
4.500 - 5.000 T4550/DB 18 0.40 1.25:1 -25 to +85 10 / 10 / 1 N2
5.200 - 5.800 T5258/DB 16 1.00 1.40:1 -25 to +85 20 / 5 / 1 N1
5.900 - 7.100 T5971/DB 16 0.60 1.40:1 -10 to +70 10 / 10 / 1 N1
7.000 - 8.500 T7085/DB 16 0.60 1.38:1 -25 to +85 10 / 10 / 1 P1
9.000 - 9.200 T9092/DB 17 0.50 1.30:1 0 to +50 5 / 5 / 1 Q2
9.000 - 10.000 T900100/DB 15 0.50 1.22:1 -25 to +85 5 / 5 / 1 Q2
10.000 - 11.000 T100110/DB 20 0.60 1.22:1 -10 to +70 20 / 10 / 1 Q3
10.000 - 11.850 T100118/DD 18 0.60 1.30:1 -10 to +70 10 / 10 / 1 Q4
12.950 - 14.500 T129145/DG 20 0.45 1.22:1 -10 to +70 5 / 5 / 1 Q1
15.000 - 18.000 T150180/DH 17 0.70 1.35:1 -25 to +85 20 / 5 / 1 U1
16.000 - 18.000 T160180/DB 17 0.70 1.33:1 0 to +50 5 / 5 / 1 V1
17.500 - 18.000 T175180/DH 20 0.70 1.25:1 -25 to +85 20 / 5 / 1 U1
17.700 - 21.200 T177212/DB 18 0.50 1.29:1 -10 to +70 5 / 5 / 1 W1
Narrowband Microstrip Isolator Specifications
FREQUENCY MODEL ISOLATION INS LOSS VSWR OPERATING PWR HANDLING PACKAGE(GHz) NUMBER (dB) MIN (dB) MAX MAX TEMP(˚C) PK/FWD/REV (W) CODE
7.100 - 8.800 T7188/DB 16 0.60 1.40:1 -10 to +70 10 / 10 / 1 N1
8.000 - 11.000 T800110/DB 16 0.50 1.50:1 -20 to +70 20 / 10 / 1 Q2
8.500 - 11.500 T850115/DB 20 0.50 1.22:1 -10 to +70 15 / 15 / 1 P2
9.000 - 11.000 T900110/DB 20 0.50 1.22:1 -10 to +70 10 / 10 / 1 P2
Page 31
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/03 31
Specifications subject to change without notice.
Microstrip Isolator Package Drawings
Microstrip Isolators
MASS = .030 oz MAXDIM = INCH MASS = .033 oz MAX
N - ISOLATOR N1 N2
21
.470
.110 MAX
.025
2X .200
.470
.025
.090 MAX
MASS = .018 oz MAXDIM = INCH MASS = .010 oz MAX
P - ISOLATOR P1 P2
.300 .033
.105 MAX
.350
1 2
.060 MAX
.0202X .060
MASS = .022 oz MAXDIM = INCH MASS = .016 oz MAXMASS = .024 oz MAXMASS = .024 oz MAX
Q - ISOLATOR Q1 Q2 Q3 Q4
1 2
.330
.130 MAX
.400
2X .070
.042 .042
.120 MAX
.042
.100 MAX
.025
.080 MAX
Page 32
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/0332
Specifications subject to change without notice.
DIM = INCH MASS = .008 oz MAX
U1 - ISOLATOR
1 2
.130 MAX
.027
2X .047
.238
.280
DIM = INCH MASS = .010 oz MAX
V1 - ISOLATOR
21
.027.200
.240
.260
.020
.090 MAX
DIM = INCH MASS = .012 oz MAX
W1 - ISOLATOR
21
.275
.130 MAX
2X .235
.305
.025
Microstrip Isolator Package Drawings
Microstrip Isolators
Page 33
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/03 33
Specifications subject to change without notice.
Microstrip Circulators
Broadband Microstrip Circulators SpecificationsModels in bold text are normally in stock for immediate delivery.
FREQUENCY MODEL ISOLATION INS LOSS VSWR OPERATING PWR HANDLING PACKAGE(GHz) NUMBER (dB) MIN (dB) MAX MAX TEMP(˚C) PK/AVG (W) CODE
4.500 - 5.000 C4550/DA 18 0.40 1.25:1 -10 to +70 10 / 10 N2
5.200 - 5.800 C5258/DA 16 1.00 1.40:1 -25 to +85 20 / 10 N1
5.900 - 7.100 C5971/DA 16 0.60 1.40:1 -10 to +70 10 / 10 N1
7.000 - 8.500 C7085/DA 16 0.60 1.38:1 -25 to +85 10 / 10 X1
9.000 - 9.200 C9092/DA 17 0.50 1.30:1 0 to +50 5 / 5 Y2
9.000 - 10.000 C900100/DA 15 0.50 1.22:1 -25 to +85 5 / 5 Y2
10.000 - 11.000 C100110/DA 20 0.60 1.22:1 -10 to +70 20 / 10 Y3
10.000 - 11.850 C100118/DC 18 0.60 1.30:1 -10 to +70 10 / 10 Y4
12.950 - 14.500 C129145/DF 20 0.45 1.22:1 -10 to +70 5 / 5 Y1
15.000 - 18.000 C150180/DG 17 0.70 1.35:1 -25 to +85 20 / 5 Z1
16.000 - 18.000 C160180/DA 17 0.70 1.33:1 0 to +50 5 / 5 Z2
17.500 - 18.000 C175180/DG 20 0.70 1.25:1 -25 to +85 20 / 5 Z1
17.700 - 21.200 C177212/DA 18 0.50 1.29:1 -10 to +70 5 / 5 W1
Narrowband Microstrip Circulators Specifications
� Low Profile
� Low Mass
� Ideal for Phased Arrays
� Space Qualified for Hybrid and MIC Modules
� Military, Space, and Commercial Applications
�Wide Operating Temperature
� Compact, Rugged Construction
� Rich Design Portfolio
� Extensive Program Heritage
FREQUENCY MODEL ISOLATION INS LOSS VSWR OPERATING PWR HANDLING PACKAGE(GHz) NUMBER (dB) MIN (dB) MAX MAX TEMP(˚C) PK/AVG (W) CODE
7.100 - 8.800 C7188/DA 16 0.60 1.40:1 -10 to +70 10 / 10 N1
8.000 - 11.000 C800110/DA 15 0.50 1.50:1 -20 to +70 20 / 10 Y2
8.500 - 11.500 C850115/DA 20 0.50 1.22:1 -10 to +70 15 / 10 V2
9.000 - 11.000 C900110/DA 20 0.50 1.22:1 -10 to +70 10 / 10 V2
Page 34
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/0334
Specifications subject to change without notice.
Microstrip Circulator Package Drawings
Microstrip Circulators
DIM = INCH MASS = .008 oz MAX
V2 - CIRCULATOR
.260
.240
.200
.200
.020.020
.060 MAX
21
3
DIM = INCH MASS = .016 oz MAX
X1 - CIRCULATOR
.300 .033 MAX
.105 MAX
2X .240
.300
.178
1
3
2
DIM = INCH MASS = .012 oz MAX
W1 - CIRCULATOR
21
.130 MAX
2X .235
.305
.275
.025
CLCC
3
MASS = .030 oz MAXDIM = INCH MASS = .033 oz MAX
N - CIRCULATOR N1 N2
21
.470
.110 MAX
.025
2X .220
.470
3
CLCC
.025
.090 MAX
Page 35
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/03 35
Specifications subject to change without notice.
Microstrip Circulator Package Drawings
Microstrip Circulators
Z - CIRCULATOR Z1 Z2
DIM = INCH MASS = .008 oz MAX MASS = .010 oz MAX
1
3
2
.161
.141
.237
.208
.130 MAX
.027.041
.090 MAX
.027
MASS = .021 oz MAXMASS = .022 oz MAXDIM = INCH MASS = .023 oz MAX MASS = .014 oz MAX
Y - CIRCULATOR Y1 Y2 Y3 Y4
2
3
1
.130 MAX
.330
.330
.042 .042
.120 MAX
.042
.100 MAX
.025
.080 MAX
2X .100
CLCC
Page 36
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/0336
Specifications subject to change without notice.
Waveguide Circulators
� High and Low Power Designs
� Isolator Designs Available
� Mass Minimized
� Low Insertion Loss
� Military, Space, and Commercial Applications
�Wide Operating Temperature
� Rich Design Portfolio
� Extensive Program Heritage
Waveguide Circulator Specifications
FREQUENCY MODEL ISOLATION INS LOSS VSWR OPERATING PWR HANDLING WAVEGUIDE(GHz) NUMBER (dB) MIN (dB) MAX MAX TEMP(˚C) PK/AVG (kW)
1.200 - 1.400 650C1214/DE 20 0.30 1.20:1 -25 to +85 100 / 5 WR650
1.200 - 1.400 650CP1214/DF 20 0.30 1.25:1 -10 to +55 210 / 5 WR650
2.375 - 2.425 340C2324/DA 20 0.20 1.20:1 -10 to +55 1.5 CW WR340
2.375 - 2.425 284C2324/DB 20 0.20 1.20:1 -10 to +55 1 CW WR284
2.700 - 3.100 284C2731/DC 23 0.30 1.15:1 -25 to +85 50 / 1.5 WR284
2.700 - 3.100 284CP2731/DD 23 0.30 1.15:1 -10 to +55 200 / 7 WR284
2.975 - 3.025 284C2930/DA 20 0.20 1.20:1 -25 to +85 2500 / 2.5 WR284
3.100 - 3.500 284C3135/DA 23 0.30 1.15:1 -25 to +85 50 / 1 WR284
3.100 - 3.500 284CP3135/DB 20 0.30 1.20:1 -10 to +55 500 / 10 WR284
3.400 - 4.200 229C3442/DI 20 0.20 1.20:1 -25 to +85 5 / 0.5 WR229
3.700 - 4.800 229C3748/DA 20 0.15 1.20:1 -25 to +85 3 / 0.15 WR229
5.200 - 5.900 187C5259/DA 23 0.25 1.15:1 -25 to +85 30 / 0.3 WR187
5.250 - 5.800 187CP5258/DA 23 0.20 1.25:1 -10 to +55 75 / 1.5 WR187
5.400 - 5.900 187C5459/DI 25 0.25 1.12:1 -25 to +85 30 / 0.3 WR187
5.850 - 6.425 137C5864/DC 25 0.15 1.12:1 -25 to +85 1 / 0.1 WR137
7.250 - 7.750 112C7277/DC 23 0.15 1.15:1 -25 to +85 1 / 0.05 WR112
7.750 - 8.250 112C7782/DA 23 0.15 1.15:1 -25 to +85 1 / 0.01 WR112
8.000 - 10.000 90C800100/DE 20 0.30 1.20:1 -25 to +85 2 / 0.02 WR90
8.500 - 9.600 90C8596/DC 23 0.20 1.15:1 -25 to +85 20 / 0.5 WR90
8.500 - 9.600 90C8596/DD 23 0.10 1.15:1 -25 to +85 100 / 0.1 WR90
9.000 - 9.500 90CP9095/DA 20 0.50 1.20:1 -25 to +85 150 / 0.15 WR90
9.000 - 10.000 90C900100/DC 23 0.20 1.15:1 -25 to +85 2 / 0.5 WR90
9.000 - 10.000 90C900100/DD 23 0.10 1.15:1 -25 to +85 100 / 0.1 WR90
9.450 - 9.950 90CP9499/DC 20 0.20 1.15:1 -25 to +70 13 / 1.3 WR90
10.750 - 12.750 75C107127/DC 23 0.20 1.15:1 -25 to +85 2 / 0.1 WR75
12.750 - 14.500 75C127145/DE 23 0.20 1.15:1 -25 to +85 2 / 0.05 WR75
13.700 - 14.500 75C137145/DA 23 0.15 1.15:1 -25 to +85 1 / 0.01 WR75
16.000 - 16.500 62C160165/DA 23 0.15 1.15:1 -25 to +85 15 / 0.5 WR62
Page 37
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/03 37
Specifications subject to change without notice.
Waveguide drawings provided upon request.
Waveguide Circulators
FREQUENCY MODEL ISOLATION INS LOSS VSWR OPERATING PWR HANDLING WAVEGUIDE(GHz) NUMBER (dB) MIN (dB) MAX MAX TEMP(˚C) PK/AVG (kW)
16.000 - 17.000 62CP160170/DA 20 0.40 1.20:1 -25 to +70 125 / 0.125 WR62
17.300 - 18.100 62CP173181/DC 20 0.40 1.20:1 0 to +55 0.8 CW WR62
17.300 - 18.300 62C173183/DD 23 0.20 1.15:1 -25 to +85 1 / 0.01 WR62
17.700 - 20.200 42C177202/DA 23 0.20 1.15:1 -25 to +85 0.05 CW / 0.01 WR42
20.200 - 21.300 51C202213/DC 23 0.20 1.15:1 -25 to +85 1 / 0.1 WR51
20.200 - 21.300 51C202213/DD 23 0.20 1.15:1 -25 to +85 0.05 / 0.001 WR51
27.500 - 30.000 34C275300/DA 23 0.15 1.15:1 -25 to +85 0.05 / 0.001 WR34
27.500 - 30.000 28CP275300/DB 20 0.50 1.20:1 0 to +55 0.5 CW WR28
27.500 - 30.500 28C275305/DC 23 0.15 1.15:1 -25 to +85 0.05 / 0.001 WR28
34.000 - 36.000 28C340360/DA 23 0.35 1.15:1 -25 to +85 1 / 0.02 WR28
34.500 - 35.500 28CP345355/DA 20 0.50 1.25:1 -10 to +55 6 / 0.2 WR28
34.500 - 35.500 28CP345355/DB 20 0.50 1.20:1 -25 to +85 70 / 0.07 WR28
43.500 - 45.500 22CP435455/DA 20 0.60 1.30:1 -10 to +55 0.1 CW WR22
Waveguide Circulator Specifications
Page 38
Typical Design Features:
� Ultra High Intermodulation Performance
� Single and Double Junction
� Integral Forward and Reverse Power Monitors
� Hybrid 2-Channel Power Combiners
� Integral Power Diode Detectors
� Integral Power Detector Circuits with TTL Output
� Reverse Power Handling Dependent on External Load
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/0338
Specifications subject to change without notice.
Wireless Coaxial Isolators and Circulators
Wireless Coaxial Isolator Specifications
FREQUENCY MODEL ISOLATION INS LOSS VSWR OPERATING PACKAGE(GHz) NUMBER (dB) MIN (dB) MAX MAX TEMP(C) CODE
0.869 - 0.894 T086089/DF 25 0.35 1.15:1 -10 to +85 AK
0.925 - 0.960 T092096/DA 28 3.50 1.15:1 -10 to +85 AH
0.925 - 0.960 T092096/DG 20 0.25 1.20:1 -10 to +85 AG
0.925 - 0.960 T092096/DH 50 0.45 1.15:1 -10 to +85 AR
0.925 - 0.960 T092096/DJ 25 0.35 1.15:1 -10 to +85 AK
0.925 - 0.960 T092096/DO 28 0.20 1.15:1 -10 to +70 AI
1.805 - 1.880 T1818/DA 28 3.50 1.15:1 -10 to +85 AH
1.805 - 1.880 T1818/DH 23 0.30 1.20:1 -10 to +80 AN
1.805 - 1.880 T1818/DJ 50 0.45 1.15:1 -10 to +85 AR
1.805 - 1.880 T1818/DK 25 0.35 1.15:1 -10 to +85 AK
1.805 - 1.880 T1818/DN 28 0.20 1.15:1 -10 to +70 AI
1.930 - 1.990 T1919/DH 50 0.45 1.20:1 -10 to +85 AR
1.930 - 1.990 T1919/DJ 25 0.35 1.15:1 -10 to +85 AK
2.070 - 2.140 T2021/DF 50 0.45 1.20:1 -10 to +85 AR
2.070 - 2.140 T2021/DG 25 0.35 1.15:1 -10 to +85 AK
Wireless Coaxial Circulator Specifications
FREQUENCY MODEL ISOLATION INS LOSS VSWR OPERATING PACKAGE(GHz) NUMBER (dB) MIN (dB) MAX MAX TEMP(C) CODE
0.869 - 0.894 C086089/DE 50 0.30 1.15:1 -10 to +70 AF
0.935 - 0.960 C093096/DA 50 0.30 1.15:1 -10 to +70 AF
1.930 - 1.990 C1919/DF 50 0.30 1.15:1 -10 to +70 AF
Page 39
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/03 39
Specifications subject to change without notice.
Wireless Coaxial Isolator and Circulator Package Drawings
Wireless Coaxial Isolators and Circulators
DIM = INCH MASS = 6.4 oz NOMINAL
AG - ISOLATOR with POWER MONITORS
2X M3.0 X .50P X .157 DEEP MIN
4X SMA FEMALE
1.57
.5
.2
.295
.5
2X .49
2.05
1.456
1.29
2X .314
.9
DIM = INCH MASS = 15.2 oz NOMINAL
AF - CIRCULATOR with POWER MONITOR
3X M3.0
1.60
.7
.200
SMBJACK
TYPE NFEMA
.680 .740
3X.512
1.025.500 2.00
2.835
TYPE N MALE
2X.160
2.05
1.06
SMAFEMALE
.240 DEEPBOTH SIDES
DIM = INCH MASS = 15.9 oz NOMINAL
AH - ISOLATOR with COMBINER
2X 1.575
2.62
2X 1.85
2X .58
4X M3.0 X 5.0 DEEP
INPUT
1.0
4X .50.6
3.00
1.10
OUTPUT
.1
4X TYPE N FEMALE
1.10
DIM = INCH MASS = 3.5 oz NOMINAL
AN - ISOLATOR with POWER MONITORS
4X .135 THRU
1.30
2X .16
2X .16
2X 2.050
2X SMB JACK
2X SMAFEMALE
12
2X .63
43
2X .985
2X1.10
2.36
4X .36
.7
DIM = INCH MASS = 6.3 oz NOMINAL
AI - ISOLATOR
2X SMAFEMALE
2X R .090
.1701.930
2X.565
2X .190
.825
.365
2.265
1.550
2X.590
2X.865
2X
1.760
Page 40
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/0340
Specifications subject to change without notice.
Wireless Coaxial Isolator and Circulator Package Drawings
Wireless Coaxial Isolators and Circulators
AK - ISOLATOR with DIODE DETECTOR
DIM = INCH MASS = 1.9 oz NOMINAL
3X .093 THRU
2X .10 TOBOTTOM OF TAB
2X.454
2X .059VOLTAGEDETECTOR
OUTPUT
.045
3X .157
2X .549
.594
.045
SMAFEMALE
.159
.320
2X .150
.1
.196
3X R .044
.688
AR - ISOLATOR with DIODE DETECTOR/TTL OUTPUT
DIM = INCH MASS = 5.1 OZ NOMINAL
.275 MAX.330
2X 1.015
.730
2.45
2X 1.865
.244
SMA FEMALE.550MAX
.37
2X .118 .2754X .138 THRU
TTL DETECTOR OUTPUT
1.735MAX
.22
3X .040
1.07
.965
3X .16
.37
3X .15
Page 41
Typical Design Features:
� Ultra High Intermodulation Performance
� Single and Double Junction
� Flow Solder, Surface Mountable
� Integral Power Diode Detectors
� Integral Power Detector Circuits with TTL Output
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/03 41
Specifications subject to change without notice.
Wireless Drop-In Isolators and Circulators
Wireless Drop-In Isolator Specifications
FREQUENCY MODEL ISOLATION INS LOSS VSWR OPERATING PACKAGE(GHz) NUMBER (dB) MIN (dB) MAX MAX TEMP(˚C) CODE
0.869 - 0.894 T086089/DA 50 0.50 1.15:1 -10 to +80 AC
0.869 - 0.894 T086089/DB 50 0.35 1.15:1 -10 to +70 AL
0.869 - 0.894 T086089/DC 22 0.30 1.20:1 -10 to +70 AE
0.869 - 0.894 T086089/DF 25 0.35 1.15:1 -10 to +85 AK
0.869 - 0.894 T086089/DH 24 0.30 1.15:1 -10 to +80 AA
0.869 - 0.894 T086089/DI 23 0.25 1.20:1 -10 to +85 AB
0.869 - 0.894 T086089/DK 21 0.25 1.20:1 -10 to +85 AV
0.869 - 0.894 T086089/DL 23 0.30 1.15:1 -10 to +80 AJ
0.925 - 0.960 T092096/DB 50 0.50 1.15:1 -10 to +80 AC
0.925 - 0.960 T092096/DC 50 0.35 1.15:1 -10 to +85 AL
0.925 - 0.960 T092096/DD 45 0.50 1.15:1 -10 to +70 AS
0.925 - 0.960 T092096/DE 22 0.30 1.20:1 -10 to +70 AE
0.925 - 0.960 T092096/DH 50 0.45 1.15:1 -10 to +85 AR
0.925 - 0.960 T092096/DJ 25 0.35 1.15:1 -10 to +85 AK
0.925 - 0.960 T092096/DL 24 0.30 1.15:1 -10 to +80 AA
0.925 - 0.960 T092096/DM 23 0.25 1.20:1 -10 to +85 AB
0.925 - 0.960 T092096/DP 21 0.25 1.20:1 -10 to +85 AV
0.925 - 0.960 T092096/DQ 23 0.30 1.15:1 -10 to +70 AJ
1.805 - 1.880 T1818/DB 50 0.50 1.15:1 -10 to +80 AC
1.805 - 1.880 T1818/DC 50 0.35 1.15:1 -10 to +85 AL
1.805 - 1.880 T1818/DD 45 0.50 1.15:1 -10 to +80 AS
1.805 - 1.880 T1818/DE 22 0.30 1.20:1 -10 to +70 AE
1.805 - 1.880 T1818/DG 24 0.30 1.15:1 -10 to +80 AA
1.805 - 1.880 T1818/DJ 50 0.45 1.15:1 -10 to +85 AR
1.805 - 1.880 T1818/DK 25 0.35 1.15:1 -10 to +85 AK
1.805 - 1.880 T1818/DM 23 0.25 1.20:1 -10 to +85 AB
1.900 - 2.030 T1920/DA 22 0.30 1.20:1 -10 to +70 AE
Page 42
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/0342
Specifications subject to change without notice.
Wireless Drop-In Isolators and Circulators
Wireless Drop-In Isolator Specifications
Wireless Drop-In Circulator Specifications
FREQUENCY MODEL ISOLATION INS LOSS VSWR OPERATING PACKAGE(GHz) NUMBER (dB) MIN (dB) MAX MAX TEMP(˚C) CODE
0.869 - 0.894 C086089/DD 22 0.30 1.20:1 -10 to +70 AP
0.869 - 0.894 C086089/DJ 23 0.35 1.15:1 -10 to +70 AD
0.925 - 0.960 C092096/DF 22 0.30 1.20:1 -10 to +70 AP
0.925 - 0.960 C092096/DN 23 0.35 1.15:1 -10 to +70 AD
1.700 - 1.900 C1719/DA 22 0.30 1.18:1 -10 to +70 AM
1.805 - 1.880 C1818/DF 22 0.30 1.20:1 -10 to +70 AP
1.805 - 1.880 C1818/DO 22 0.30 1.18:1 -10 to +70 AM
1.900 - 2.030 C1920/DB 22 0.30 1.20:1 -10 to +70 AP
1.930 - 1.990 C1919/DE 22 0.30 1.20:1 -10 to +70 AP
1.930 - 1.990 C1919/DM 22 0.30 1.18:1 -10 to +70 AM
2.070 - 2.140 C2021/DK 22 0.30 1.18:1 -10 to +70 AM
2.095 - 2.185 C2021/DO 22 0.30 1.20:1 -10 to +70 AT
FREQUENCY MODEL ISOLATION INS LOSS VSWR OPERATING PACKAGE(GHz) NUMBER (dB) MIN (dB) MAX MAX TEMP(˚C) CODE
1.930 - 1.990 T1919/DA 50 0.50 1.15:1 -10 to +80 AC
1.930 - 1.990 T1919/DB 50 0.35 1.15:1 -10 to +85 AL
1.930 - 1.990 T1919/DC 45 0.50 1.15:1 -10 to +70 AS
1.930 - 1.990 T1919/DD 22 0.30 1.20:1 -10 to +70 AE
1.930 - 1.990 T1919/DH 50 0.45 1.20:1 -10 to +85 AR
1.930 - 1.990 T1919/DJ 25 0.35 1.15:1 -10 to +85 AK
1.930 - 1.990 T1919/DK 23 0.25 1.20:1 -10 to +85 AB
1.930 - 1.990 T1919/DL 24 0.30 1.15:1 -10 to +80 AA
1.930 - 1.990 T1919/DN 21 0.25 1.20:1 -10 to +85 AV
1.930 - 1.990 T1919/DO 23 0.30 1.15:1 -10 to +70 AJ
2.070 - 2.140 T2021/DC 50 0.50 1.15:1 -10 to +80 AC
2.070 - 2.140 T2021/DD 50 0.35 1.15:1 -10 to +85 AL
2.070 - 2.140 T2021/DF 50 0.45 1.20:1 -10 to +85 AR
2.070 - 2.140 T2021/DG 25 0.35 1.15:1 -10 to +85 AK
2.070 - 2.140 T2021/DI 23 0.25 1.20:1 -10 to +85 AU
2.070 - 2.140 T2021/DJ 24 0.30 1.15:1 -10 to +80 AA
2.070 - 2.140 T2021/DL 21 0.25 1.20:1 -10 to +85 AV
2.070 - 2.140 T2021/DM 23 0.30 1.15:1 -10 to +70 AJ
2.095 - 2.185 T2021/DN 22 0.30 1.20:1 -10 to +70 AE
Page 43
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/03 43
Specifications subject to change without notice.
Wireless Drop-In Isolator and Circulator Package Drawings
Wireless Drop-In Isolators and Circulators
DIM = INCH MASS = 1.1 oz NOMINAL
AA - ISOLATOR
4X .102 THRU
1.250
2X .300
2X.820
2X .820
1.000
2X .090
2X .090
2X .120
2X .025
4X .140
2X .15 TOBOTTOMOF TAB
.315
DIM = INCH MASS = 1 oz NOMINAL
AB - ISOLATOR
4X .094 THRU
1.250
2X .305
2X .818 2X .025
1.000
2X .818
2X .090
2X .090
2X .120 .062
2X .15
.47
AC - ISOLATOR
DIM = INCH MASS = 2.3 oz NOMINAL
4X .095 THRU
6X .150
3X .15 TOBOTTOM OF TAB
2X .995
1.250
3X .090
.315MAX
.820
2X .090
2.170
2X .9952X .10
2X .30
2X .025
DIM = INCH MASS = .6 oz NOMINAL
AE - ISOLATOR
.915
.595
1.100
2X .200
2X .270
2XCONTACT PAD
.310
2X .110
DIM = INCH MASS = 1.6 oz NOMINAL
AD - CIRCULATOR
4X .130 THRU 3X .18
2X .105
.435
2X.840
1.055
2X .105
3X .160
1.055
2X .840
2X .815
3X .060
Page 44
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/0344
Specifications subject to change without notice.
Wireless Drop-In Isolator and Circulator Package Drawings
Wireless Drop-In Isolators and Circulators
AK - ISOLATOR with DIODE DETECTOR
DIM = INCH MASS = 1.9 oz NOMINAL
3X .093 THRU
2X .10 TOBOTTOM OF TAB
2X.454
2X .059VOLTAGEDETECTOR
OUTPUT
.045
3X .157
2X .549
.594
.045
SMAFEMALE
.159
.320
2X .150
.1
.196
3X R .044
.688
AL - ISOLATOR
DIM = INCH MASS = 4.4 oz NOMINAL
4X .138 THRU
2X 2.4802X .135
2X .46
2X .050 WIDE.005 - .010 THICK
2X .135
2X1.225
1.500MAX
2.750 MAX
2X .16
.063
2X .16 TOBOTTOM OF TAB
.490MAX
AJ - ISOLATOR
DIM = INCH MASS = 1.1 oz NOMINAL P3 AND P4 ARE NON-DIRECTIONAL POWER COUPLERS
4X .110 THRU
2X 1.069
4X .12 TOBOTTOM OF TAB
1.250
2X 1.069
2X .025.2
2X .185 MAXP4
2X .091
1.250
.394
P2
P3
2X .050
2X .118MAX
P1.733
2X .30 2X .091.063 REF
Page 45
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/03 45
Specifications subject to change without notice.
Wireless Drop-In Isolator and Circulator Package Drawings
Wireless Drop-In Isolators and Circulators
DIM = INCH MASS = .5 oz NOMINAL
AM - CIRCULATOR
4X THRU
2X .025
2X .090
2X.570
.750
2X .505
2X .0902X
.570
.750 3X .070
3X .12
.250
.085 .075
DIM = INCH MASS = .6 oz NOMINAL
AP - CIRCULATOR
3X .270
3X .110
.915
2X .785
1.100
3X .090CONTACTPAD
.305
AR - ISOLATOR with DIODE DETECTOR/TTL OUTPUT
DIM = INCH MASS = 5.1 OZ NOMINAL
.275 MAX.330
2X 1.015
.730
2.45
2X 1.865
.244
SMA FEMALE.550MAX
.37
2X .118 .2754X .138 THRU
TTL DETECTOR OUTPUT
1.735MAX
.22
3X .040
1.07
.965
3X .16
.37
3X .15
DIM = INCH MASS = 1.8 oz NOMINAL
AS - ISOLATOR
4X .114 THRU 2X .090
2X.819
1.00
2X .090
2X 1.750
1.930
2X.3
2X .050
.452MAX
2X .12 2X .16
.062
DIM = INCH MASS = .6 oz NOMINAL
AT - CIRCULATOR
3X .270
3X .110
.915
2X .785
1.100
3X .090CONTACTPAD
.370
Page 46
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/0346
Specifications subject to change without notice.
Wireless Drop-In Isolator and Circulator Package Drawings
Wireless Drop-In Isolators and Circulators
DIM = INCH MASS = .9 oz NOMINAL
AU - ISOLATOR
4X .095 THRU
2X .025
2X .30
2X .10
2X.820
1.250
2X .090
2X .090 2X .820
1.000
.050
2X .13
.370
DIM = INCH MASS = 2.4 oz NOMINAL
AV - ISOLATOR
4X .125 THRU
2X .120
2X1.070
1.580
2X .120
2X .35
2X 1.070
1.305
2X .16
2X .055
.560MAX
2X.050
2X .07 TOBOTTOM OF TAB
Page 47
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/03 47
Specifications subject to change without notice.
Integration by Design
TRAK Microwave’s general capability includes isolator and circulator custom-designed assemblies,multifunction assemblies, sources, and subsystems. In addition to our broad line of isolator andcirculator components, TRAK specializes in the design and manufacture of Integrated MicrowaveAssemblies (IMAs) for defense, space, and commercial applications.
Offering distinct advantages over multiple, interconnected and discrete functions, IMAs take advantage ofthe latest advances in performance and functionality to offer a form fit and function upgrade path fromexisting outdated technology. In doing so, IMAs also offer overall improved performance, reliability andare ideally suited to applications where electrical performance and mechanical constraints are often theprime considerations. TRAK integrated assemblies provide cost and time savings associated with theelimination of multiple interconnects and individual component testing.
Receiver Front End
Typical Applications:� Radar Subsystems� Receiver Subsystems� Electronic Warfare Subsystems� Communications Subsystems
Integrated Assemblies May Include:� Switches� Limiters� Filters� Couplers� Phase Shifters
Page 48
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/0348
Specifications subject to change without notice.
Integration by Design
X-Band Marine Radar Passive Front End
Features:
� Highly Integrated Structure
� Magnetically Shielded
� Model Shown Features the Optional High Power Limiter
� Low Pass Filter Designed to Eliminate MagnetronSpurious Products
Benefits:
� Cost Effective
� Superior EMC Performance
� Suitable for High Volume Production
Specifications:
� Insertion Loss:Tx - ANT 0.50 dBANT - Rx 0.25 dBANT - Rx 0.55 dB (when limiter option specified)
� Return Loss: 23 dB Min
� Forward Power: 10 kW (when limiter option specified)
LIMITER
ISOLATOR
TRANSFORMERWG
OPTIONAL
HIGH POWERTERMINATION
LPF
ANT PORT
RxWR90
TxWR90
CIRCULATOR
X - BAND MARINE RADAR PASSIVE FRONT END
Page 49
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/03 49
Specifications subject to change without notice.
Integration by Design
X-Band Microstrip Duplexer with Limiter
Features:
� Highly Integrated Structure
� Magnetically Shielded
Benefits:
� Small Size
� Integrated Limiter
� Space Qualified
� Ultra Low Mass, Ideal for Integration within Microwave Hybrid
Specifications:
� Insertion Loss:Tx - ANT 0.6 dB MaxANT - Rx (through limiter) 1.2 dB Max
�Isolation:ANT - Tx 36 dB Min
� Return Loss (All ports): 20 dB Min
� Limiter Leakage (ANT - Rx): +10 dBm with ANT = +36 dBm
PIN LIMITER
ISOLATOR
ANTTx
CIRCULATOR
Rx
TERMINATION
X - BAND MICROSTRIP DUPLEXER WITH LIMITER
Page 50
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/0350
Select-A-Frequency Instructions
If the electrical performance offered by our broadband models do not meet your minimum requirements and yourdesired model is not available in the Narrowband tables of Coaxial, Drop-in and MICpuck devices, then TRAK’sSelect-A-Frequency devices are available as a semi-custom alternative.
To determine which Select-A-Frequency device to order, follow the instructions below:
1. Select the table of Select-A-Frequency isolators or circulators in the appropriate topology (e.g. coaxial, drop-in).
2. Determine your operating center frequency and operating percentage bandwidth (BW). Select the center frequencyrange containing your operating center frequency from the table’s first column. If your operating BW is equal to or less than that stated in the % BW column, then TRAK will guarantee the performance stated.
3. To order a Select-A-Frequency device, you must generate your own model number by replacing the "*" with the center frequency code, which is created as follows.
a) The frequency code is the center frequency in GHz, multiplied by 100. Drop any fractional values(no decimal places). Add leading zeroes, if necessary, to make the frequency code four digits.
b) If counter-clockwise circulation is desired, add an "X" suffix to the model number. If clockwise is desired,add an “N”.
Example: You need a coaxial circulator operating from 6.3 to 6.8 GHz. You cannot locate this model in the narrow-band tables. Referring to the Coaxial Select-A-Frequency table, you identify that the C6080/S*A covers the range inwhich your operating center frequency (6.55 GHz) lies and your actual BW (7.7%) is considerably less than the 15%maximum that the C6080/S*A will operate over.
Having met your system demands, you generate the model number by replacing the "*" with the frequency code,6.55 GHz X 100 = 0655. The model number is C6080/S0655AN.
TRAK ships the device with a worst-case electrical performance of 23 dB minimum isolation, 0.50 dB maximum inser-tion loss, 1.20:1 maximum VSWR, power handling of 500 W peak, 65 W average, guaranteed over –25° to +85° C.
Circulator/IsolatorC = CirculatorT = Isolator
V
Choose 4 - 6 DigitFrequency Band From
Select-A-Frequency Table
V
S =Select-A-Frequency
V
S
Customer-Generated 4 Digit Center FrequencyCode: = GHz X 100� Any Fractional Values Are Dropped (No Decimal Places)� Add Leading Zeros To Make 4 Digits, If Necessary.
V
Insert SequenceCode From
Select-A-FrequencyTable
V
Customer-Generated Direction
of Circulaton:X = CCW
N = CW (Normal)
V
*
Select-A-Frequency Model Number Configuration
Page 51
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/03 51
Basic Theory
Circulators and isolators provide non-reciprocal transmission paths. In other words, microwave energy may travelthe transmission path in one direction with little loss, but will be greatly absorbed when applied from the oppositedirection.
Isolators and circulators use ferrite material in the presence of a magnetic field to achieve this non-reciprocaloperation. The magnetic field is set so that an applied RF or microwave signal interacts with the electrons withinthe ferrite material. There is a resonance frequency determined by the atomic makeup of the ferrite material andthe applied magnetic field. The non-reciprocal action of a ferrite component isdetermined by the proximity of the applied signal frequency to the resonance frequency of that component.
The junction circulator uses ferrite material in the presence of a magnetic bias fieldto provide the non-reciprocal action described above. The ideal circulator is definedas an n-port loss-less passive network in which energy introduced at one port istransferred wholly to an adjacent port while decoupling the energy from all otherports. The basic circulator building block is the three-port circulator, which isrepresented symbolically in Figure 1. A signal applied to port 1 emerges from port2, energy applied to port 2 emerges from port 3, and energy entering port 3emerges from port 1. In the idealized circulator, absolute isolation exits betweenadjacent ports opposite to the direction of flow (that is, port 3 to port 2, port 2 toport 1, and port 1 to port 3) because, theoretically, energy cannot flow opposite tothe direction of circulation.
Figure 1: Schematic representation ofthree-port circulator
Since it is impossible to achieve a loss-less or reflection-less network, the isolation between two adjacent ports is lessthan absolute and actually depends on the VSWR of the third port; the isolation is actually the return loss due to thisthird port mismatch. This is represented graphically in Figure 2. This figure assumes that the third port is terminatedwith a perfectly matched load; obviously, this is not practically achievable.
Junction isolators are a form of the junction circulator with thethird port terminated with a dummy load (termination). If port1 is the input port, energy reflected from port 2 circulates tothe termination where it is dissipated as heat. When the isolator is operated with the load removed or shorted (infiniteVSWR); nearly all the incident power will be reflected to thetermination. If the isolator is to tolerate infinite load VSWR,then the termination power rating must equal or, preferably,exceed the maximum incident power.
Figure 2: Circulator isolation as a result of thirdport VSWR (assumes perfectly matched load)
3
21
ISO
LAT
ION
VSWR
40
30
20
10
01 1.5 2 2.5 3 4 6 10 20 50
Page 52
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/0352
1 2
2
1
1
2
ConnectorsAlthough coaxial devices are indicated as generally having SMA (female) on all ports, TRAK offers SMA (male) connectors as a no cost option. The default isolator connector orientation is 180 degrees diametrically opposed; how-ever 90 degrees may be specified as a no cost option. Isolator connector orientation is shown in Figure 4. TRAKconnectors meet the dimensional interface requirements of MIL-C-39012. All connectors on these components aretorque tested at 12 inch-pounds before shipment. Since MIL-C-39012 specifies mating torque at only 7 to 10 inch-pounds, this assures that the user will have no problems with connectors rotating in the housing when a properlytorqued mating connector is engaged or disengaged.
Figure 4: Isolator Connector Orientation
Circulation
The default direction of circulation is clockwise from port 1 to port 2 when looking at the device from above. You may specify counterclockwise circulation asa no cost option. Clockwise circulation is defined on TRAK parts as the low insertion loss path found between port 1 to port 2, from port 2 to port 3 and fromport 3 to port 1, as depicted in Figure 3.
General Notes & Diagrams
ConstructionTRAK devices feature a cover that is threaded into a thick one-piece steel body to aid magnetic shielding and toreduce susceptibility to stray fields while virtually eliminating radiated fields. Parts are assembled into the housingunder high compression. This eliminates air gaps between the circuit element and the ferrite or garnet elements and between other components. The result is more uniform performance characteristics, which vary less over temperature and which exhibit a very linear phase versus frequency response plus enhanced reliability.
3
1 2
DC BlocksAvailable, please contact factory.
Electric & Magnetic ShieldingWith the exception of open structure microstrip designs, TRAK devices offer superior magnetic and electrical shieldingwith minimized radiation and susceptibility to electromagnetic fields. TRAK always recommends maximizing distancebetween any isolator and circulator device, stray magnetic fields, and ferrous materials.
Figure 3: Default Circulation
Page 53
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/03 53
General Notes & Diagrams
Test FixturesIn order to correctly measure the performance of drop-in isolators and circulators, a properly maintained test fixture is necessary. TRAK recommends that customers purchase a test fixture only if there is an unusual need for precisemeasurement of the isolator or circulator performance. In most system applications, the exact performance of thecomponent is far less critical than proper system performance.
TerminationsThe standard 1-watt termination may be configured on any port as a no cost option. Higher power terminations are available.
TestingAll models are tested at + 22˚C and at small signal levels. Inset limits ensure that all devices meet the stipulated performance over the stated operating temperature range. Additional testing can be performed at an additional cost.
Operating TemperaturePerformance is guaranteed over the specified operating range. Generally however, the devices will operate over widertemperature ranges (e.g.-54˚ to +95˚C), although minor microwave performance degradation may be apparent.
Multi-Junction DevicesConfigurations of high isolation isolators or duplexing junctions (iso-circulators) are available as standard parts.Contact the factory for information and availability of multi-junction designs.
Power HandlingA nominal power rating, which is guaranteed at the maximum rated operating temperature, is stated for all units. Thepower handling capability of an isolator and circulator is the level of power that can be safely handled provided the unitis in contact with a heat sink that is maintained at a maximum temperature of +50˚C. The specified peak powerapplies at operating pressures approximately equivalent to 10,000 feet above sea level. For space applications,multipaction can occur at lower power levels than specified.
When applied power is increased sufficiently, the circulator elements begin to heat due to insertion loss. At higher levels of heating, the performance of the circulator is degraded. In the worst case, the Curie temperature of the isolator or circulator elements can be reached and all non-reciprocal action ceases.
Tab LeadsThe tab leads on all drop-in units are extensions of the isolator and circulator center conductor. There are no solderjoints except for those at the isolator termination. Tab leads are .005" +/- .001 thick beryllium copper; silver plated orsolder tinned (gold plating optional).
Page 54
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/0354
Mounting Considerations
MountingDrop-in models require some special consideration. The tabs are preformed at the factory to provide optimum contact with the circuit and a tension free solder joint. For optimal performance, this shape should not be changedand the space between the vertical edge of the isolator and circulator housing and the user's circuit should be minimized. The unit should be mounted on the flat surface opposite the recessed cover. The bottom of the unit mustbe flush with the mounting surface to ensure a proper ground. Figures 5, 6 and 7 depict several unacceptable types ofcontact. The recommended contact is shown in Figure 8.
CAUTION: TRAK Microwave strongly advises that drop-in units not be operated in a "reverse circulation" manner byturning units "upside down", as the tab shape and location relative to the circuit may not be optimal. In some cases,especially at lower frequencies, "upside down" mounting will cause no harm; however, TRAK Microwave guaranteesperformance only when the standard mounting surface is used.
Unreliable PointContact on Endof Microstrip
TestFixture
Circ
ulat
or o
r Is
olat
or
Tab
MicrostripLine
Added Shunt CapacitanceCauses Error
Dielectric forPressureContact
TestFixture
Tab
MicrostripLine
Circ
ulat
or o
r Is
olat
or
TestFixture
♦ Short Formed "Spring" Contact
♦ Can Be Tested In Final System
Before Soldering
♦ "Tension" Free Solder Joint
Best
Tab
MicrostripLine
Circ
ulat
or o
r Is
olat
or
"Point" ContactUnreliable
TestFixture
Tab
MicrostripLine
Circ
ulat
or o
r Is
olat
or
Figure 5: Unreliable Contact Figure 6: Unreliable Contact
Figure 7: Parasitic Shunt Capacitance Figure 8: Recommended Contact
Page 55
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/03 55
Mounting Considerations
Isolators and circulators may be mounted with epoxy, fluxless solder, or screw mounted. Other than screwmounting, the following four mounting methods are routinely used successfully with TRAK devices:
� Conductive Epoxy Preform: A 0.005" or similar thick glass supported conductive film cut to the diameter ofthe unit. Use per manufacturer's instructions. This is the recommended method of mounting.
� Low Melting Point Solder: Apply small amount on both surfaces and reflow. Maximum solder temperatureis 150˚C for 30 seconds.
NOTE: Care must be taken in employing solder or epoxies to avoid solder wicking up the sides, especially in the area of the tabs. The tabs on the drop-in isolators and circulators are factory formed for optimum circuit contact. They should not be straightened and should be handled with care.
� Conductive Epoxy: Spread small amount over entire bottom surface.
� Clamping Plate: An aluminum plate with mounting holes on top of the unit. Maximum pressure should not exceed 2.2 Kg, (5 lbs.).
NOTE: Do not apply pressure to the recessed cover because the housing may distort, resulting in performance degradation.
Page 56
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/0356
Model Number Cross Reference
This cross reference is included for guidance only. Please be aware that model numbers selected from this catalog may differslightly from those ordered from previous catalogs. All older TRAK model numbers continue to be supported and can be orderedby specifying the original part number.
Old Model New Model Topology Page
10*0501 C050070/S*C COAXIAL 10
10*0601 C070010/S*A COAXIAL 10
10*1401 C1013/S*A COAXIAL 10
10*1501 C1316/S*A COAXIAL 10
10*1551 C1316/S*B COAXIAL 10
10*1601 C1620/S*C COAXIAL 10
10*2201 C150180/S*A COAXIAL 10
10*3401 C2025/S*C COAXIAL 10
10*3501 C2532/S*A COAXIAL 10
10*3551 C3038/S*A COAXIAL 10
10*3601 C3040/S*A COAXIAL 10
10*6401 C3650/S*A COAXIAL 10
10*6501 C4860/S*A COAXIAL 10
10A1431 C1214/DA COAXIAL 9
10A2441 C120150/DC COAXIAL 9
10A3641 C2023/DA COAXIAL 9
10A8021 C180220/DA COAXIAL 9
10B0051 C042045/DA COAXIAL 9
10B0151 C085095/DA COAXIAL 9
10B1031 C095012/DA COAXIAL 8
10B1401 C1011/DA COAXIAL 9
10B1551 C1415/DA COAXIAL 9
10B1601 C1618/DA COAXIAL 9
10B1631 C1821/DA COAXIAL 9
10B2201 C120180/DE COAXIAL 9
10B2441 C150180/DE COAXIAL 10
10B3401 C2223/DA COAXIAL 9
10B3602 C3742/DA COAXIAL 9
10B6401 C4244/DA COAXIAL 9
10B6501 C5459/DA COAXIAL 9
10B9201 C800124/DK COAXIAL 8
10CD320 284C2324/DB WAVEGUIDE 36
10CD330 284C2930/DA WAVEGUIDE 36
10CD334 284C3135/DA WAVEGUIDE 36
10CD39 284C2731/DC WAVEGUIDE 36
10CP103 284CP2731/DD WAVEGUIDE 36
10CP118 284CP3135/DB WAVEGUIDE 36
10H6501 C6572/DA COAXIAL 9
11ACD312 229C3442/DI WAVEGUIDE 36
11ACD314 229C3748/DA WAVEGUIDE 36
12CD319 187C5459/DI WAVEGUIDE 36
12CD325 187C5259/DA WAVEGUIDE 36
12CP406 187CP5258/DA WAVEGUIDE 36
14CD7519 137C5864/DC WAVEGUIDE 36
Old Model New Model Topology Page
15CD343 112C7277/DC WAVEGUIDE 36
15CD345 112C7782/DA WAVEGUIDE 36
16CD3104 90C8596/DD WAVEGUIDE 36
16CD3110 90C900100/DD WAVEGUIDE 36
16CD347 90C900100/DC WAVEGUIDE 36
16CD372 90C800100/DE WAVEGUIDE 36
16CD389 90C8596/DC WAVEGUIDE 36
16CP20 90CP9499/DC WAVEGUIDE 36
16CP7 90CP9095/DA WAVEGUIDE 36
17CD308 75C127145/DE WAVEGUIDE 36
17CD319 75C107127/DC WAVEGUIDE 36
17CD350 75C137145/DA WAVEGUIDE 36
18CD315 62C160165/DA WAVEGUIDE 36
18CD341 62C173183/DD WAVEGUIDE 37
18CP16 62CP173181/DC WAVEGUIDE 37
18CP17 62CP160170/DA WAVEGUIDE 37
19*0401 C050070/S*A DROP-IN 21
19*0501 C070010/S*C DROP-IN 21
19*1401 C1013/S*C DROP-IN 21
19*1501 C1316/S*E DROP-IN 21
19*1601 C1620/S*A DROP-IN 21
19*2401 C120150/S*A DROP-IN 21
19*2501 C150180/S*C DROP-IN 21
19*3401 C2025/S*A DROP-IN 21
19*3501 C2537/S*A DROP-IN 21
19*6401 C3746/S*A DROP-IN 21
19*6501 C4662/S*A DROP-IN 21
19*6601 C6280/S*A DROP-IN 21
19*9401 C800100/S*A DROP-IN 21
19*9501 C100120/S*A DROP-IN 21
19A0701 C042045/DC DROP-IN 20
19A11001 C096012/DA DROP-IN 19
19A1801 C1415/DC DROP-IN 20
19A2211 C1010/DB DROP-IN 20
19A31281 C3742/DD DROP-IN 20
19A31291 C3036/DA DROP-IN 20
19A3301 C1214/DC DROP-IN 20
19A3801 C3742/DC DROP-IN 20
19A6501 C5459/DC DROP-IN 20
19A6801 C5964/DA DROP-IN 20
19CD305 51C202213/DD WAVEGUIDE 37
19CD309 51C202213/DC WAVEGUIDE 37
19D3401 C2223/DC DROP-IN 20
19D6401 C4244/DC DROP-IN 20
Page 57
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/03 57
Model Number Cross Reference
This cross reference is included for guidance only. Please be aware that model numbers selected from this catalog may differslightly from those ordered from previous catalogs. All older TRAK model numbers continue to be supported and can be orderedby specifying the original part number.
Old Model New Model Topology Page
19K3501 C2729/DA DROP-IN 20
19N1401 C098010/DA DROP-IN 20
19Q3501 C2527/DC DROP-IN 20
20*0501 T050070/S*D COAXIAL 5
20*0601 T070010/S*B COAXIAL 5
20*1401 T1013/S*B COAXIAL 5
20*1501 T1316/S*C COAXIAL 5
20*1551 T1316/S*D COAXIAL 5
20*1601 T1620/S*D COAXIAL 5
20*2201 T150180/S*B COAXIAL 5
20*3401 T2025/S*D COAXIAL 5
20*3501 T2532/S*B COAXIAL 5
20*3551 T3038/S*B COAXIAL 5
20*3601 T3040/S*B COAXIAL 5
20*6401 T3650/S*B COAXIAL 5
20*6501 T4860/S*B COAXIAL 5
20A0001 T042045/DB COAXIAL 4
20A2441 T120150/DD COAXIAL 4
20A2541 T120200/DB COAXIAL 4
20A3851 T2760/DB COAXIAL 3
20A8021 T180220/DB COAXIAL 4
20AV3401 T2223/DB COAXIAL 4
20B0151 T085095/DB COAXIAL 4
20B1401 T1011/DB COAXIAL 4
20B1551 T1415/DB COAXIAL 4
20B1611 T1618/DB COAXIAL 4
20B2201 T120180/DF COAXIAL 4
20B2441 T150180/DF COAXIAL 5
20B3501 T2731/DB COAXIAL 4
20B3551 T3035/DB COAXIAL 4
20B3602 T3742/DB COAXIAL 4
20B6401 T4244/DB COAXIAL 4
20B6501 T5459/DB COAXIAL 4
20B9201 T800124/DL COAXIAL 3
20B9461 T7884/DB COAXIAL 4
20BC6501 T7077/DB COAXIAL 4
20BS3401 T2123/DB COAXIAL 4
20C1361 T095012/DB COAXIAL 3
20CD311 42C177202/DA WAVEGUIDE 37
20N6501 T6572/DB COAXIAL 4
21CD301 34C275300/DA WAVEGUIDE 37
22CD319 28C340360/DA WAVEGUIDE 37
22CD324 28C275305/DC WAVEGUIDE 37
22CP405 28CP345355/DB WAVEGUIDE 37
Old Model New Model Topology Page
22CP407 28CP275300/DB WAVEGUIDE 37
22CP411 28CP345355/DA WAVEGUIDE 37
23CP401 22CP435455/DA WAVEGUIDE 37
29*0401 T050070/S*B DROP-IN 16
29*0501 T070010/S*D DROP-IN 16
29*1401 T1013/S*D DROP-IN 16
29*1501 T1316/S*F DROP-IN 16
29*1601 T1620/S*B DROP-IN 16
29*2401 T120150/S*B DROP-IN 16
29*2501 T150180/S*D DROP-IN 16
29*3401 T2025/S*B DROP-IN 16
29*3501 T2537/S*B DROP-IN 16
29*6401 T3746/S*B DROP-IN 16
29*6501 T4662/S*B DROP-IN 16
29*6601 T6280/S*B DROP-IN 16
29*9401 T800100/S*B DROP-IN 16
29*9501 T100120/S*B DROP-IN 16
29A0701 T042045/DD DROP-IN 14
29A11001 T096012/DB DROP-IN 13
29A11221 T1010/DC DROP-IN 14
29A11731 T1011/DC DROP-IN 14
29A1801 T1415/DD DROP-IN 14
29A31281 T3742/DF DROP-IN 14
29A31291 T3036/DB DROP-IN 14
29A3301 T1214/DD DROP-IN 14
29A3801 T3742/DE DROP-IN 14
29A61521 T7075/DB DROP-IN 14
29AG6501 T5459/DE DROP-IN 14
29BM3501 T2729/DB DROP-IN 14
29G6601 T5964/DC DROP-IN 14
29T3401 T2223/DD DROP-IN 14
29U6401 T4244/DF DROP-IN 14
29W3501 T2527/DD DROP-IN 14
50*2001 C800150/S*A COAXIAL 10
50A1101 C1020/DA COAXIAL 8
50A2001 C800160/DA COAXIAL 9
50A2051 C800180/DA COAXIAL 9
50A2171 C700180/DA COAXIAL 8
50A2401 C800200/DA COAXIAL 9
50A2601 C600180/DA COAXIAL 8
50A2701 C650180/DA COAXIAL 8
50A3001 C2040/DA COAXIAL 8
50A3011 C2652/DA COAXIAL 8
50A3401 C2060/DA COAXIAL 8
Page 58
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/0358
Model Number Cross Reference
This cross reference is included for guidance only. Please be aware that model numbers selected from this catalog may differslightly from those ordered from previous catalogs. All older TRAK model numbers continue to be supported and can be orderedby specifying the original part number.
Old Model New Model Topology Page
50A6001 C4080/DF COAXIAL 8
50A6071 C500100/DA COAXIAL 8
50A6301 C3060/DA COAXIAL 8
50A8101 C180265/DA COAXIAL 9
50A9201 C600120/DA COAXIAL 8
50C2001 C100120/DC COAXIAL 10
50E2001 C800100/DC COAXIAL 8
59A2201 C120180/DH DROP-IN 19
59A2601 C600180/DC DROP-IN 19
59A3101 C2040/DC DROP-IN 19
59A3301 C2652/DC DROP-IN 19
59A6001 C4080/DH DROP-IN 19
59A6051 C470100/DA DROP-IN 19
59A6101 C500100/DC DROP-IN 19
59A6201 C3060/DC DROP-IN 19
59A9201 C800120/DF DROP-IN 19
59A9301 C800160/DC DROP-IN 19
60*2001 T800150/S*B COAXIAL 5
60A1101 T1020/DB COAXIAL 3
60A2001 T800160/DB COAXIAL 4
60A2051 T800180/DB COAXIAL 4
60A2171 T700180/DB COAXIAL 3
60A2241 T600180/DB COAXIAL 3
60A2261 T750180/DB COAXIAL 3
60A2401 T800200/DB COAXIAL 4
60A2411 T127145/DB COAXIAL 5
60A2701 T650180/DB COAXIAL 3
60A3001 T2040/DB COAXIAL 3
60A3011 T2652/DB COAXIAL 3
60A3401 T2060/DB COAXIAL 3
60A6001 T4080/DG COAXIAL 3
60A6071 T500100/DB COAXIAL 3
60A6221 T3066/DB COAXIAL 3
60A6301 T3060/DB COAXIAL 3
60A6431 T500110/DB COAXIAL 3
60A8101 T180265/DB COAXIAL 4
60A9201 T600120/DB COAXIAL 3
60B2001 T800100/DD COAXIAL 3
60BD2001 T110127/DD COAXIAL 5
60D2001 T100120/DD COAXIAL 5
61A2651 T100150/DB COAXIAL 4
61A6161 T3675/DB COAXIAL 3
69A2031 T800180/DD DROP-IN 13
69A2041 T750180/DD DROP-IN 13
Old Model New Model Topology Page
69A2201 T120180/DK DROP-IN 13
69A2601 T600180/DD DROP-IN 13
69A3101 T2040/DD DROP-IN 13
69A3111 T2652/DD DROP-IN 13
69A6001 T4080/DI DROP-IN 13
69A6051 T470100/DB DROP-IN 13
69A6101 T500100/DD DROP-IN 13
69A6201 T3060/DD DROP-IN 13
69A9201 T800120/DI DROP-IN 13
69A9301 T800160/DD DROP-IN 13
6CD304 650C1214/DE WAVEGUIDE 36
6CP405 650CP1214/DF WAVEGUIDE 36
9ACD301 340C2324/DA WAVEGUIDE 36
BO 10B1631 T1821/DB COAXIAL 4
C07179/A T049071/DB COAXIAL 3
C08096/A T080096/DB COAXIAL 4
C112117/A C112117/DA COAXIAL 10
C120128/A C120128/DA COAXIAL 10
C2228/A C2228/DA COAXIAL 8
C2931/B C2931/DA DROP-IN 20
C3442/B C3442/DA COAXIAL 8
C3642/A C3642/DC MICPUCK 27
C9A2021 T160180/DB MICROSTRIP 30
C9A9011 C7085/DA MICROSTRIP 33
C9A9071 C9092/DA MICROSTRIP 33
C9A9071 T9092/DB MICROSTRIP 30
C9A9A10 C850115/DA MICROSTRIP 33
C9B9051 C900100/DA MICROSTRIP 33
C9B9A03 C800110/DA MICROSTRIP 33
C9B9A10 C900110/DA MICROSTRIP 33
D9A2021 T175180/DH MICROSTRIP 30
D9A2A04 T129145/DG MICROSTRIP 30
D9A6011 T5971/DB MICROSTRIP 30
D9A6021 T5258/DB MICROSTRIP 30
D9A6A01 T7188/DB MICROSTRIP 30
D9A6A09 T4550/DB MICROSTRIP 30
D9A8A06 T177212/DB MICROSTRIP 30
D9A8A07 T150180/DH MICROSTRIP 30
D9A9A09 T100110/DB MICROSTRIP 30
D9C9A08 T100118/DD MICROSTRIP 30
ETC1011A1 C2225/DA COAXIAL 9
F9*2001 T120180/S*B DROP-IN 16
F9*6101 T4080/S*B DROP-IN 16
F9*9001 T800120/S*B DROP-IN 16
Page 59
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/03 59
Model Number Cross Reference
This cross reference is included for guidance only. Please be aware that model numbers selected from this catalog may differslightly from those ordered from previous catalogs. All older TRAK model numbers continue to be supported and can be orderedby specifying the original part number.
Old Model New Model Topology Page
F9A2201 T120180/DI DROP-IN 13
F9A2501 T115129/DB DROP-IN 15
F9A6101 T4244/DE DROP-IN 14
F9A6461 T7077/DC DROP-IN 14
F9A8011 T195203/DC DROP-IN 15
F9A9021 T9299/DA DROP-IN 15
F9A9101 T800120/DH DROP-IN 13
F9A9441 T7494/DA DROP-IN 13
F9A9611 T8696/DA DROP-IN 15
F9AE9001 T950105/DB DROP-IN 15
F9J6101 T4752/DA DROP-IN 14
FA96141 T3743/DA DROP-IN 14
G9*2001 C120180/S*A DROP-IN 21
G9*6101 C4080/S*A DROP-IN 21
G9*9001 C800120/S*A DROP-IN 21
G9A2201 C120180/DG DROP-IN 19
G9A6161 C4252/DA DROP-IN 19
G9A8021 C180265/DC DROP-IN 19
G9A9101 C800120/DG DROP-IN 19
G9B6101 C5459/DD DROP-IN 20
G9C6101 C5964/DB DROP-IN 20
G9C9001 C950105/DA DROP-IN 20
G9D6101 C4244/DD DROP-IN 20
GTD1005A1 T4450/DB DROP-IN 14
H9*6101 T4080/S*C DROP-IN 16
H9*9001 T800120/S*C DROP-IN 16
H9A2201 T120180/DJ DROP-IN 13
H9A8061 T176216/DC DROP-IN 13
H9A8071 T180265/DD DROP-IN 13
H9A8081 T193198/DB DROP-IN 15
H9A8101 T220225/DB DROP-IN 15
H9A8151 T225240/DB DROP-IN 15
H9A9101 T800120/DJ DROP-IN 13
H9B6101 T4244/DG DROP-IN 14
H9B9001 T950105/DC DROP-IN 15
H9C6101 T5459/DF DROP-IN 14
H9D6101 T5964/DD DROP-IN 14
I1011/G T1010/DB MICPUCK 24
I104113/C T104113/DB DROP-IN 15
I105113/B T105113/DD COAXIAL 5
I105130/B T105130/DB MICPUCK 24
I107117 T107117/DB MICPUCK 25
I107118/A T107119/DD DROP-IN 15
I107127/A T107127/DB MICPUCK 25
Old Model New Model Topology Page
I108128/A C107128/DD DROP-IN 21
I110130/B T110130/DB MICPUCK 25
I112120/A T110120/DB COAXIAL 5
I114118/A T114117/DC MICPUCK 25
I114128/B T114127/DA COAXIAL 5
I117127 T117127/DD MICPUCK 25
I121128/B T121128/DB DROP-IN 15
I1214/O T1214/DB COAXIAL 4
I125141/A T125141/DB DROP-IN 15
I127135/A C127135/DA DROP-IN 21
I127138 T127138/DD MICPUCK 25
I127145/A T127145/DC DROP-IN 15
I130150/A T130150/DB COAXIAL 5
I137145/A T127145/DD DROP-IN 15
I140145/O T140145/DB MICPUCK 25
I1516/K T1515/DB DROP-IN 14
I1516/M T1516/DB COAXIAL 4
I1516/U T1515/DD MICPUCK 24
I172179/A C172179/DC DROP-IN 21
I173181/C T173181/DB DROP-IN 15
I1731855/A T173185/DF MICPUCK 25
I178190/A T178190/DB MICPUCK 25
I181191/A T181191/DB MICPUCK 25
I188202/A T188202/DB MICPUCK 25
I194215/A T194215/DB COAXIAL 5
I195205/D T195205/DB MICPUCK 25
I197200/C T197202/DE COAXIAL 5
I200206/A T200206/DB MICPUCK 25
I2022/E T1921/DB DROP-IN 14
I202212/A T202212/DB MICPUCK 25
I2023/A T2023/DB COAXIAL 4
I210220/A T210230/DB MICPUCK 25
I2123/G T2123/DF MICPUCK 24
I2123/J T2123/DD DROP-IN 14
I2325/D T2325/DB MICPUCK 24
I2428/B T2428/DB MICPUCK 24
I2527/F T2527/DB COAXIAL 4
I2529/C T2529/DB MICPUCK 24
I2729/B T2729/DD MICPUCK 24
I2833/A T2833/DB DROP-IN 14
I2838/B T2838/DB COAXIAL 3
I2933/A T2933/DB MICPUCK 24
I3437/C T3437/DB DROP-IN 14
I3438/N T3438/DB MICPUCK 24
Page 60
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/0360
Model Number Cross Reference
This cross reference is included for guidance only. Please be aware that model numbers selected from this catalog may differslightly from those ordered from previous catalogs. All older TRAK model numbers continue to be supported and can be orderedby specifying the original part number.
Old Model New Model Topology Page
I3442/E T3442/DF DROP-IN 13
I3442/F T3442/DH MICPUCK 24
I3442/G T3442/DC COAXIAL 3
I3442/S T3442/DD COAXIAL 3
I3537/B T3537/DB MICPUCK 24
I3642/E C3642/DA DROP-IN 20
I4050/A T4050/DB COAXIAL 3
I4080/A T3780/DB COAXIAL 3
I4448/D T4448/DB MICPUCK 24
I4547/A T4547/DB DROP-IN 14
I4650/A T4749/DB MICPUCK 24
I5157/A T5156/DB COAXIAL 4
I5157/B T5156/DD DROP-IN 14
I5865/B T5864/DE MICPUCK 24
I5865/E T5864/DB DROP-IN 14
I5867/A T5866/DB COAXIAL 4
I5962/A T5962/DB MICPUCK 24
I6467/B T6467/DB MICPUCK 24
I6667/A T6673/DD MICPUCK 24
I6771/A T6771/DB COAXIAL 4
I6771/C T6771/DD MICPUCK 25
I6772/A C6673/DA DROP-IN 20
I6775/B T6774/DB COAXIAL 4
I6876/B T6976/DB DROP-IN 14
I70100/A T700100/DB COAXIAL 3
I7090/A T7090/DB COAXIAL 3
I7177/B T7177/DB DROP-IN 14
I7179/B T7178/DB DROP-IN 14
I7179/D T7178/DD MICPUCK 25
I7274/A T7274/DB MICPUCK 25
I7278/B T7277/DB MICPUCK 25
I7476/A T7476/DB MICPUCK 25
I7581/A T7580/DB MICPUCK 25
I7584/A T7584/DB DROP-IN 14
I7885/G T7884/DF MICPUCK 25
I7885/H T7884/DD MICPUCK 25
I7886/A T7886/DB DROP-IN 14
I8083/A T8082/DB MICPUCK 25
I8085/B C8085/DB DROP-IN 20
I8085/D T8085/DC DROP-IN 14
I8596/B T8596/DB COAXIAL 4
I90105/B T900105/DF DROP-IN 15
I9499/A T9499/DB MICPUCK 25
I97112/A T970112/DB DROP-IN 15
Old Model New Model Topology Page
L9*2001 C120180/S*C MICPUCK 28
L9*6001 C4080/S*D MICPUCK 28
L9*9001 C800120/S*D MICPUCK 28
M9*2001 T120180/S*D MICPUCK 25
M9*6001 T4080/S*E MICPUCK 25
M9*9001 T800120/S*E MICPUCK 25
M9A2361 T131147/DB MICPUCK 25
M9A3091 T2021/DB MICPUCK 24
M9A6081 T4345/DB MICPUCK 24
M9A8081 T171179/DB MICPUCK 25
M9A9291 T8594/DB MICPUCK 25
M9A9411 T980108/DB MICPUCK 25
M9B2371 T134150/DB MICPUCK 25
M9B3101 T3133/DB MICPUCK 24
M9B6121 T7173/DB MICPUCK 25
M9D6001 T5459/DH MICPUCK 24
NEW MODEL C039045/DA COAXIAL 9
NEW MODEL C049071/DA COAXIAL 8
NEW MODEL C080096/DA COAXIAL 9
NEW MODEL C086089/DD DROP-IN 42
NEW MODEL C086089/DE COAXIAL 38
NEW MODEL C086089/DJ COAXIAL 42
NEW MODEL C092096/DF DROP-IN 42
NEW MODEL C092096/DN COAXIAL 42
NEW MODEL C093096/DA COAXIAL 38
NEW MODEL C100110/DA MICROSTRIP 33
NEW MODEL C100118/DC MICROSTRIP 33
NEW MODEL C100150/DA COAXIAL 9
NEW MODEL C1010/DA MICPUCK 27
NEW MODEL C1011/DB DROP-IN 20
NEW MODEL C104113/DA DROP-IN 20
NEW MODEL C105113/DC COAXIAL 10
NEW MODEL C105130/DA MICPUCK 27
NEW MODEL C107117/DA MICPUCK 28
NEW MODEL C107119/DC DROP-IN 21
NEW MODEL C107127/DA MICPUCK 28
NEW MODEL C110120/DA COAXIAL 10
NEW MODEL C110127/DC COAXIAL 10
NEW MODEL C110130/DA MICPUCK 28
NEW MODEL C114117/DB MICPUCK 28
NEW MODEL C117127/DC MICPUCK 28
NEW MODEL C120200/DA COAXIAL 9
NEW MODEL C121128/DA DROP-IN 21
NEW MODEL C125141/DA DROP-IN 21
Page 61
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/03 61
Model Number Cross Reference
This cross reference is included for guidance only. Please be aware that model numbers selected from this catalog may differslightly from those ordered from previous catalogs. All older TRAK model numbers continue to be supported and can be orderedby specifying the original part number.
Old Model New Model Topology Page
NEW MODEL C127138/DC MICPUCK 28
NEW MODEL C127145/DA COAXIAL 10
NEW MODEL C129145/DF MICROSTRIP 33
NEW MODEL C130150/DA COAXIAL 10
NEW MODEL C131147/DA MICPUCK 28
NEW MODEL C134150/DA MICPUCK 28
NEW MODEL C140145/DA MICPUCK 28
NEW MODEL C150180/DG MICROSTRIP 33
NEW MODEL C1515/DA DROP-IN 20
NEW MODEL C1515/DC MICPUCK 27
NEW MODEL C1516/DA COAXIAL 9
NEW MODEL C160180/DA MICROSTRIP 33
NEW MODEL C171179/DA MICPUCK 28
NEW MODEL C1719/DA DROP-IN 42
NEW MODEL C173181/DA DROP-IN 21
NEW MODEL C173185/DE MICPUCK 28
NEW MODEL C175180/DG MICROSTRIP 33
NEW MODEL C175215/DA DROP-IN 19
NEW MODEL C177212/DA MICROSTRIP 33
NEW MODEL C178190/DA MICPUCK 28
NEW MODEL C181191/DA MICPUCK 28
NEW MODEL C1818/DF DROP-IN 42
NEW MODEL C1818/DO DROP-IN 42
NEW MODEL C188202/DA MICPUCK 28
NEW MODEL C190200/DA DROP-IN 21
NEW MODEL C1919/DE DROP-IN 42
NEW MODEL C1919/DF COAXIAL 38
NEW MODEL C1919/DM DROP-IN 42
NEW MODEL C1920/DB DROP-IN 42
NEW MODEL C1921/DA DROP-IN 20
NEW MODEL C193198/DA DROP-IN 21
NEW MODEL C194215/DA COAXIAL 10
NEW MODEL C195205/DA MICPUCK 28
NEW MODEL C200206/DA MICPUCK 28
NEW MODEL C2021/DA MICPUCK 27
NEW MODEL C2021/DK DROP-IN 42
NEW MODEL C2021/DO DROP-IN 42
NEW MODEL C202212/DA MICPUCK 28
NEW MODEL C210230/DA MICPUCK 28
NEW MODEL C2123/DA COAXIAL 9
NEW MODEL C2123/DC DROP-IN 20
NEW MODEL C2123/DE MICPUCK 27
NEW MODEL C220225/DA DROP-IN 21
NEW MODEL C225240/DA DROP-IN 21
Old Model New Model Topology Page
NEW MODEL C226231/DA DROP-IN 21
NEW MODEL C2325/DA MICPUCK 27
NEW MODEL C2428/DA MICPUCK 27
NEW MODEL C2527/DA COAXIAL 9
NEW MODEL C2529/DA MICPUCK 27
NEW MODEL C2729/DC MICPUCK 27
NEW MODEL C2731/DA COAXIAL 9
NEW MODEL C2760/DA COAXIAL 8
NEW MODEL C2833/DA DROP-IN 20
NEW MODEL C2838/DA COAXIAL 8
NEW MODEL C2933/DA MICPUCK 27
NEW MODEL C3035/DA COAXIAL 9
NEW MODEL C3066/DA COAXIAL 8
NEW MODEL C3133/DA MICPUCK 27
NEW MODEL C3437/DA DROP-IN 20
NEW MODEL C3438/DA MICPUCK 27
NEW MODEL C3442/DB COAXIAL 8
NEW MODEL C3442/DE DROP-IN 19
NEW MODEL C3442/DG MICPUCK 27
NEW MODEL C3537/DA MICPUCK 27
NEW MODEL C3675/DA COAXIAL 8
NEW MODEL C3780/DA COAXIAL 8
NEW MODEL C4050/DA COAXIAL 8
NEW MODEL C4345/DA MICPUCK 27
NEW MODEL C4448/DA MICPUCK 27
NEW MODEL C4450/DA DROP-IN 20
NEW MODEL C4547/DA DROP-IN 20
NEW MODEL C4550/DA MICROSTRIP 33
NEW MODEL C4749/DA MICPUCK 27
NEW MODEL C500110/DA COAXIAL 8
NEW MODEL C5156/DA COAXIAL 9
NEW MODEL C5156/DC DROP-IN 20
NEW MODEL C5258/DA MICROSTRIP 33
NEW MODEL C5459/DG MICPUCK 27
NEW MODEL C5864/DA DROP-IN 20
NEW MODEL C5864/DD MICPUCK 27
NEW MODEL C5866/DA COAXIAL 9
NEW MODEL C5962/DA MICPUCK 27
NEW MODEL C5971/DA MICROSTRIP 33
NEW MODEL C6080/S*A COAXIAL 10
NEW MODEL C6467/DA MICPUCK 27
NEW MODEL C6673/DC MICPUCK 27
NEW MODEL C6771/DA COAXIAL 9
NEW MODEL C6771/DC MICPUCK 28
Page 62
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/0362
Model Number Cross Reference
This cross reference is included for guidance only. Please be aware that model numbers selected from this catalog may differslightly from those ordered from previous catalogs. All older TRAK model numbers continue to be supported and can be orderedby specifying the original part number.
Old Model New Model Topology Page
NEW MODEL C6774/DA COAXIAL 9
NEW MODEL C6976/DA DROP-IN 20
NEW MODEL C700100/DA COAXIAL 8
NEW MODEL C7075/DA DROP-IN 20
NEW MODEL C7077/DA COAXIAL 9
NEW MODEL C7090/DA COAXIAL 8
NEW MODEL C7173/DA MICPUCK 28
NEW MODEL C7177/DA DROP-IN 20
NEW MODEL C7178/DA DROP-IN 20
NEW MODEL C7178/DC MICPUCK 28
NEW MODEL C7188/DA MICROSTRIP 33
NEW MODEL C7274/DA MICPUCK 28
NEW MODEL C7277/DA MICPUCK 28
NEW MODEL C7476/DA MICPUCK 28
NEW MODEL C750180/DA COAXIAL 8
NEW MODEL C750180/DC DROP-IN 19
NEW MODEL C7580/DA MICPUCK 28
NEW MODEL C7584/DA DROP-IN 20
NEW MODEL C7884/DA COAXIAL 9
NEW MODEL C7884/DC MICPUCK 28
NEW MODEL C7884/DE MICPUCK 28
NEW MODEL C7886/DA DROP-IN 20
NEW MODEL C800180/DC DROP-IN 19
NEW MODEL C8082/DA MICPUCK 28
NEW MODEL C8085/DA DROP-IN 20
NEW MODEL C8594/DA MICPUCK 28
NEW MODEL C8596/DA COAXIAL 9
NEW MODEL C900105/DE DROP-IN 20
NEW MODEL C9499/DA MICPUCK 28
NEW MODEL C970112/DA DROP-IN 20
NEW MODEL C980108/DA MICPUCK 28
NEW MODEL T039045/DB COAXIAL 4
NEW MODEL T086089/DA DROP-IN 41
NEW MODEL T086089/DB DROP-IN 41
NEW MODEL T086089/DC DROP-IN 41
NEW MODEL T086089/DF COAXIAL 38,41
NEW MODEL T086089/DG DROP-IN 41
NEW MODEL T086089/DH DROP-IN 41
NEW MODEL T086089/DI DROP-IN 41
NEW MODEL T086089/DK DROP-IN 41
NEW MODEL T086089/DL DROP-IN 41
NEW MODEL T092096/DA COAXIAL 38
NEW MODEL T092096/DB DROP-IN 41
NEW MODEL T092096/DC DROP-IN 41
Old Model New Model Topology Page
NEW MODEL T092096/DD DROP-IN 41
NEW MODEL T092096/DE DROP-IN 41
NEW MODEL T092096/DG COAXIAL 38
NEW MODEL T092096/DH COAXIAL 38,41
NEW MODEL T092096/DJ COAXIAL 38,41
NEW MODEL T092096/DL DROP-IN 41
NEW MODEL T092096/DM DROP-IN 41
NEW MODEL T092096/DO COAXIAL 38
NEW MODEL T092096/DP DROP-IN 41
NEW MODEL T092096/DQ COAXIAL 41
NEW MODEL T098010/DB DROP-IN 14
NEW MODEL T107128/DE DROP-IN 15
NEW MODEL T120128/DB COAXIAL 5
NEW MODEL T127135/DB DROP-IN 15
NEW MODEL T172179/DD DROP-IN 15
NEW MODEL T175215/DB DROP-IN 13
NEW MODEL T1818/DA COAXIAL 38
NEW MODEL T1818/DB DROP-IN 41
NEW MODEL T1818/DC DROP-IN 41
NEW MODEL T1818/DD DROP-IN 41
NEW MODEL T1818/DE DROP-IN 41
NEW MODEL T1818/DG DROP-IN 41
NEW MODEL T1818/DH COAXIAL 38
NEW MODEL T1818/DJ COAXIAL 38,41
NEW MODEL T1818/DK COAXIAL 38,41
NEW MODEL T1818/DM DROP-IN 41
NEW MODEL T1818/DN COAXIAL 38
NEW MODEL T190200/DB DROP-IN 15
NEW MODEL T1919/DA DROP-IN 41
NEW MODEL T1919/DB DROP-IN 42
NEW MODEL T1919/DC DROP-IN 42
NEW MODEL T1919/DD DROP-IN 42
NEW MODEL T1919/DH COAXIAL 38,42
NEW MODEL T1919/DJ COAXIAL 38,42
NEW MODEL T1919/DK DROP-IN 42
NEW MODEL T1919/DL DROP-IN 42
NEW MODEL T1919/DN DROP-IN 42
NEW MODEL T1919/DO DROP-IN 42
NEW MODEL T1920/DA DROP-IN 41
NEW MODEL T2021/DC DROP-IN 42
NEW MODEL T2021/DD DROP-IN 42
NEW MODEL T2021/DF COAXIAL 38,42
NEW MODEL T2021/DG COAXIAL 38.42
NEW MODEL T2021/DI DROP-IN 42
Page 63
TRAK MicrowaveE-mail: [email protected] � www.trak.com
4726 Eisenhower Blvd Dunsinane AvenueTampa, Florida 33634-6391 USA Dundee, DD2 3QF Scotland
Ph: 813-901-7200 � Fx: 813-901-7491 Ph: 44-1382-427200 � Fx: 44-1382-833599
©TRAK Microwave Corp. Doc #FL309 01/03 63
Model Number Cross Reference
This cross reference is included for guidance only. Please be aware that model numbers selected from this catalog may differslightly from those ordered from previous catalogs. All older TRAK model numbers continue to be supported and can be orderedby specifying the original part number.
Old Model New Model Topology Page
NEW MODEL T2021/DJ DROP-IN 42
NEW MODEL T2021/DL DROP-IN 42
NEW MODEL T2021/DM DROP-IN 42
NEW MODEL T2021/DN DROP-IN 42
NEW MODEL T2225/DB COAXIAL 4
NEW MODEL T2228/DB COAXIAL 3
NEW MODEL T226231/DB DROP-IN 15
NEW MODEL T2931/DB DROP-IN 14
NEW MODEL T3642/DB DROP-IN 14
NEW MODEL T3642/DD MICPUCK 24
NEW MODEL T6080/S*B COAXIAL 5
NEW MODEL T6673/DB DROP-IN 14
NEW MODEL T7085/DB MICROSTRIP 30
NEW MODEL T800110/DB MICROSTRIP 30
NEW MODEL T8085/DD DROP-IN 15
NEW MODEL T850115/DB MICROSTRIP 30
NEW MODEL T900100/DB MICROSTRIP 30
NEW MODEL T900110/DB MICROSTRIP 30