The TP8-28 and TP8-28 GSM systems implement the Tecnoalarm RSC technology right from the basic versions. The advantages and the performance offered by the RSC technology are now available to realize even small-sized installations with a high level of technology. Expandable serial alarm systems TP8-28 – TP8-28 GSM
6
Embed
TP8-28 ENG LR - tecnoalarm.it · The TP8-28 and TP8-28 GSM systems implement the Tecnoalarm RSC technology right from the basic versions. The advantages and the performance offered
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
The TP8-28 and TP8-28 GSM systems implement the
Tecnoalarm RSC technology right from the basic versions.
The advantages and the performance offered by the RSC
technology are now available to realize even small-sized
installations with a high level of technology.
Expandable serial alarm systems
TP8-28 – TP8-28 GSM
Zone
Configuration
System
Configuration
8
Programs
1 2 3 4 5Finger
100Acces Period
4
Key
100Yearly Calendar
2
Trasmitter
80Timer
6
Code
120
OPERATINGCODES
AUTOMATICFUNCTIONS
Wired
28
Wireless
28
Logic
Zones28
Tecnoalarm Technology
ZonesSystem configuration is entirely modular thanks to the input expansion modules.The 2 conventional and the 6 bus inputs of the CPU constitute the basic version ofthe system. They are expandable to a total of 28 zones which can be freely associatedto the hard-wired (conventional or bus) or wireless inputs of the connected hardware.The zone programming facilities allow to obtain excellent performances even fromtraditional detectors but the best results are obtained by using the Tecnoalarm RDVand RSC detectors. These detectors permit the verification and analysis of the alarmsat the very moment they are released, through the specific diagnostic tools of themonitoring software. In this way, the limitations of traditional remote managementhave been overcome and a new concept of interaction has been proposed.(RDV® and RSC® are registered trademarks and protected by international patents)
The Tecnoalarm systems which are equipped with the(Remote Sensitivity Control) technology communicate withthe monitoring station and transmit specific and detailedinformation. The Tecnoalarm monitoring station can programand constantly monitor the system from a distance and, usingsophisticated diagnostic tools, verify the smooth functioningand obtain the necessary information to maintain and improveits performance.
ProgrammingProgramming of the system’s functioning parameters can be madelocally or remotely, via telephone line, using the Tecnoalarm software.The software provides numerous programming tools which permitcustomization of the installation selecting the most appropriate amongthe options available.
Programs and control unitsThe TP8-28 and TP8-28 GSM systems manage 8 programs. A wide range of controlunits is able to satisfy any application requirements. The range comprises theLCD300/S console with voice synthesis, the new LCDPROX1 console with graphicdisplay and transponder reader, RFID card and finger print readers as well as theexclusive TSP7000 STD consoles with 7 inches touch screen and, for the STD-BIOversion, with biometric finger print reader. The users have access to the system’sfunctions through 120 codes, 100 transponders/RFID cards, 80 wireless keys and100 finger prints. Access to the protected areas can be automated and regulatedby 4 access periods and 6 timers.
TelephoneCommunication
Wireless
Controls
Remote
Advanced
Configuration
Data File
Events
Alarm
Photo
dBm level
RF Monitor
LowHigh
Bad
Timers
64
Actions
128
Phone Book
6
Counters
16
Synoptic
4
SMS DTMF
Lights Shutters
Roller
Irrigation
8 RemoteControl
VOICE RINGSMS DTMFFSK DATI
PSTNInterface
TP8-28 SYSTEMCOMMUNICATION
DEVICE
TP8-28 GSM SYSTEMCOMMUNICATION
DEVICE
156 PROTOCOLS
GSM-GPRSModule
Ethernet59 PROTOCOLS
GSM-GPRSModule
Ethernet
Event BufferCapacity
1500
Download SavePrint
Consoles
2Sirens
2Sensor
28
WIRELESSDEVICES
Event logThe event log contains all the events relating to the system’s functioning, i.e.the alarms, the diagnostics and the changes of status. A total of 1500 eventscan be recorded, in reverse chronological order, with indication of date and time. For each event, detailed information is given about the interested zones,programs and remote controls, identified by a number and a description,as well as the telephone calls. For each alarm detected by the RSC detectorsa graph showing the detector’s functioning at the moment of alarm releaseis also stored. The installer can download the event log at any time using theTecnoalarm software and extract the necessary information to verify thesystem’s smooth functioning.
Advanced programmingThe advanced programming tool is a software expansion of the programmingfacilities of the TP8-28 and TP8-28 GSM systems permitting a large extent ofcustomization extending the system’s resources and integrating homeautomation functions. It allows to offer functional solutions to particularapplication requirements making cost-expensive external devices redundantand implementing the PLC (programmable logic controller) programming logic.The conventional functionality of the inputs, outputs, channels, remote controlsetc. is redefined through a series of actions, associated to the events.The actions can be linked and scheduled by timers and counters.
Telephone sectionThe telephone section provides 8 telephone channels. The TP8-28 system uses thePSTN line and optionally the GSM or Ethernet network through respectively the externalGSM communicator TECNOCELL-PRO PL and the PROG NET2 Ethernet interface.The TP8-28 GSM system uses the GSM network through the integrated GSM/GPRSinterface or the external GSM communicator TECNOCELL PRO-PL and optionally theEthernet network through the PROG NET2 Ethernet interface. According to the system,TP8-28 or TP8-28 GSM and the vector, the telephone section uses several communicationformats: voice calls, SMS or data transmission in FSK, DTMF and TCP/IP formats.The alarm and system status messages are automatically composed by the systemusing the onboard vocabulary. The TP8-28 and TP8-28 GSM systems communicate withthe user and the central monitoring stations using respectively 156 and 59 communicationprotocols.
Wireless sectionThe expansion of the system is possible, even if cable laying is complicated,by the installation of maximum 2 wireless receivers or receiver-transmittersable to manage a total of 80 wireless keys, 28 wireless detectors as well as,respectively, 2 wireless consoles and sirens. The wireless communication,i.e. the transmissions of the alarm signal and the automatic test signal (supervision),is constantly verified and analyzed and the detected interferences, transformedinto a graph, can be consulted, locally or remotely, using the RF Monitor diagnostictool of the Tecnoalarm software. The wide range of Tecnoalarm wireless detectors,comprising indoor and outdoor detectors as well as perimeter protections, offersideal solutions for all protection requirements.
InteractionThe TP8-28 and TP8-28 GSM systems provide 8 remote controls whichallow the user to interact with the systems through telephone calls orSMS messages. The remote controls are customizable and permit the management of the system’s functions as well as the interaction with external devices such as heating, air-conditioning, lighting equipment etc.
SENSOR BUS
PROG USB PROG NET2 TSP LINK
ETHERNET
TSP7000 STD-BIOTSP7000 STD
SRA
SRINT
OUT2 OUT2
OUT1 OUT1 OUT1
SIREN BUS
SPEED ALM8 PLUS SPEED 8 PLUS SPEED 4 PLUS SPEED ALM8 PL
SAEL 2010 BUS
TP SDNTECNOCELL-PRO PL ESP32-OCNSINOTTICO 32N
+ SRA
- SIR
- OUT1
- OUT2
APR CARD APR FINGER APR FINGER-CARD
SRA
SRINT
OUT2
OUT1
OUT2
OUT1 OUT1
SPEED 8 SPEED 4 SPEED 8 STD
RX300/433868 RTX200/433868
SIREN BUS
LCD300/S LCDPROX1 SERIAL BUS
ESP4-20 TP PROX
Mar 10 GEN 12Feri. 13:46
4
8
3
7
2
6
1
5
6 DEVICES
2 DEVICES
8 DEVICES
2 DEVICES
1 DEVICE 12 DEVICES
TP8-28 – TP8-28 GSM SYSTEM CONFIGURATION
8 DEVICES
1 DEVICE
28 DEVICES
2 DEVICES
2 DEVICES
2 DEVICES
PROG INTERFACE
RSC DETECTORS
Mar 10 GEN 12Feri. 13:46
4
8
3
7
2
6
1
5
TP OUT6OCV+ -
SRE-
SRI- OUT
1 2 3 4
TP PROXLED V+L1 L2 L3 KR1L4 KR0
TP OUTRELC NO NC
TP BUSVOC+ - A B S
ESP BUSTP BUS+ - A B
SPEED ALM8 PLUS SPEED 8 PLUS SPEED 4 PLUS SPEED 8 SPEED 4