TP Calorimetry and particle ID Jaewon Park
18

TP Calorimetry and particle ID Jaewon Park. 2 Calorimetry We assumed that (dE/dx) min is constant for differe nt particles. In previous study: Hcal.

Dec 19, 2015

Download

Documents

Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: TP Calorimetry and particle ID Jaewon Park. 2 Calorimetry We assumed that (dE/dx) min is constant for differe nt particles. In previous study:  Hcal.

TP Calorimetry and particle ID

Jaewon Park

Page 2: TP Calorimetry and particle ID Jaewon Park. 2 Calorimetry We assumed that (dE/dx) min is constant for differe nt particles. In previous study:  Hcal.

2

Calorimetry

We assumed that (dE/dx)min is constant for different particles.

In previous study: Hcal calibration constant is acquired from proton beam

study. Ecal calibration constant is acquired from electron beam

study.

In TP(tracker+DS-Ecal) study, it shows we can’t use same calibration constant for proton and electron.

Page 3: TP Calorimetry and particle ID Jaewon Park. 2 Calorimetry We assumed that (dE/dx) min is constant for differe nt particles. In previous study:  Hcal.

3

Proton -- Ecal calibration constant

Old study showed Ecal calibration constant 2.5 is better than 1.75

Mean of (recoE-trueE)/trueE become constant for theta, Vz depedence

Value 1.75 is from dE/dx weighting.

Calorimetry constant 2.5 overestimates proton’s energy.K_ecal=1.5 K_ecal=1.75

K_ecal=2.5

Page 4: TP Calorimetry and particle ID Jaewon Park. 2 Calorimetry We assumed that (dE/dx) min is constant for differe nt particles. In previous study:  Hcal.

4

TP Detector – Proton

Ecal calib. constatant = 2.5

Page 5: TP Calorimetry and particle ID Jaewon Park. 2 Calorimetry We assumed that (dE/dx) min is constant for differe nt particles. In previous study:  Hcal.

5

Nu_e electron events (k_ecal=1.5)

It underestimates electron’s energy.

Page 6: TP Calorimetry and particle ID Jaewon Park. 2 Calorimetry We assumed that (dE/dx) min is constant for differe nt particles. In previous study:  Hcal.

6

Nu_e electron energy (k_ecal=2.5)

2.5 shows better energy reconstuction.

It’s consistent with previous Ecal study with electron beam.

Page 7: TP Calorimetry and particle ID Jaewon Park. 2 Calorimetry We assumed that (dE/dx) min is constant for differe nt particles. In previous study:  Hcal.

7

Nu_e electron energy (k_ecal=2.5)

When electron track is reconstructed.

Page 8: TP Calorimetry and particle ID Jaewon Park. 2 Calorimetry We assumed that (dE/dx) min is constant for differe nt particles. In previous study:  Hcal.

8

dE/dx

From graph, dE/dx (electron) is higher thatn dE/dx (proton) around 2-5GeV

scintscintmin

scintscintminiron

leadminscint

losstotalloss )(

)()(

L

LLEE

dxdE

dxdE

dxdE

Page 9: TP Calorimetry and particle ID Jaewon Park. 2 Calorimetry We assumed that (dE/dx) min is constant for differe nt particles. In previous study:  Hcal.

9

dE/dx of reconstructed tracks

Particle beam is shot perpendicular to scintillator planes in semi-infinite tracker.

To localize only beginning of track, it process dE variable until: slope>1, dr>1, and nStrips>3

Also required track length > 10cm. Examined two variables:

dE variable in track ntuple. Sum of dE / track length

Page 10: TP Calorimetry and particle ID Jaewon Park. 2 Calorimetry We assumed that (dE/dx) min is constant for differe nt particles. In previous study:  Hcal.

10

dE/dx of reconstructed tracks

Upper two plots shows mean values of distribution

Bottom two plots shows Gaussian fit values of distribution.

Fit value Fit value

Mean value Mean value

Page 11: TP Calorimetry and particle ID Jaewon Park. 2 Calorimetry We assumed that (dE/dx) min is constant for differe nt particles. In previous study:  Hcal.

11

dE sum / track length

dE sum/ trk length > 0.18

Low energy proton dE/dx looks like electron or gamma.

Page 12: TP Calorimetry and particle ID Jaewon Park. 2 Calorimetry We assumed that (dE/dx) min is constant for differe nt particles. In previous study:  Hcal.

12

dE sum / track length

Page 13: TP Calorimetry and particle ID Jaewon Park. 2 Calorimetry We assumed that (dE/dx) min is constant for differe nt particles. In previous study:  Hcal.

13

(Backup slides)

dE sum/track length – individual plots

Page 14: TP Calorimetry and particle ID Jaewon Park. 2 Calorimetry We assumed that (dE/dx) min is constant for differe nt particles. In previous study:  Hcal.

14

Gamma

Page 15: TP Calorimetry and particle ID Jaewon Park. 2 Calorimetry We assumed that (dE/dx) min is constant for differe nt particles. In previous study:  Hcal.

15

Gamma

Page 16: TP Calorimetry and particle ID Jaewon Park. 2 Calorimetry We assumed that (dE/dx) min is constant for differe nt particles. In previous study:  Hcal.

16

Electron

Page 17: TP Calorimetry and particle ID Jaewon Park. 2 Calorimetry We assumed that (dE/dx) min is constant for differe nt particles. In previous study:  Hcal.

17

Electron

Page 18: TP Calorimetry and particle ID Jaewon Park. 2 Calorimetry We assumed that (dE/dx) min is constant for differe nt particles. In previous study:  Hcal.

18

Proton