Personal Wireless Monitor For Toxic Gases and Oxygen
The ToxiRAE Pro is the world’s first wireless personal monitor for toxic gases and oxygen1. The ToxiRAE Pro can detect a broad range of gases—from carbon monoxide, hydrogen sulfide, and oxygen to ammonia, chlorine, and formaldehyde2. The ToxiRAE Pro provides safety professionals wireless remote access to real-time instrument readings and alarm status for better visibility and faster incident response. The ToxiRAE Pro’s intelligent interchangeable sensors store calibration data, which allows users to monitor for one gas one day and another gas the next, by simply swapping the sensors in the ToxiRAE Pro3.
• Wirelesselevatessafetytothenextlevel
• Over20intelligentinterchangeablesensoroptionstocoverawidevarietyofgases
• ManDownAlarmwithreal-timeremotewirelessnotification
• Easytomaintainwithreplaceablesensor,filter,andLi-ionbattery
• Fully-automaticbumptestingandcalibrationwithAutoRAE22
KEyFEAtuREs
Wireless. Personal. Proven.
•Wirelessaccesstoreal-timeinstrumentreadingsandalarmstatusfromanylocation
•Unmistakablefive-waylocalandremotewirelessnotificationofalarmconditions
• Intelligentsensorsstorecalibrationdata,sotheycanbeswappedinthefield
•MostelectrochemicalsensorsaresharedwithMultiRAEfamilyinstruments
•Largestdisplayinitsclass
•Continuousdatalogging
•Easytouse
•Reliable,rugged,andintrinsicallysafe
AppLicAtiOns
•Agriculture
•Chemical
•Fireservice/HazMat
•Foodandbeverage
•Oilandgas
•Pharmaceutical
•Pulpandpaper
•Steelmanufacturing
•Waterandwastewaterindustries
The world’s first personal wireless monitor protects workers from toxic gases without getting in the way
ToxiRAE Pro
R
USC
Page 2
spEciFicAtiOns
ToxiRAE ProPersonal Wireless Monitor for Toxic Gases and Oxygen
DS-1064-05
tOxiRAEpROcOMEsWith:• ToxiRAEPromonitorwithsensorasspecified,alligatorclip,protectiverubberboot,andrechargeablebatteryinstalled
• ChargingandPCcommunicationcradle• PCcommunicationcable• ACadapter(100to240V,50/60HzACto12VDC)• Calibrationadapters• QuickStartGuide• CDwithdocumentation• ProRAEStudioIIsoftwareforPC-basedinstrumentconfigurationanddatamanagement
• Calibrationcard,qualitycertificate,andwarranty/registrationcard
OptiOnALAccEssORiEs• AutoRAE2AutomaticTestandCalibrationSystem• Multi-unitchargingstationforuptofivemonitors
ORDERinginFORMAtiOn(MODEL:pgM-1860)• Wirelessornon-wirelessversionsareavailable1
• Bulkpackagesof10unitsareavailableforselectconfigurations• RefertothePortablesPricingGuideforpartnumbersformonitors,accessories,maintenancekits,gas,sensors,andreplacementparts
instrumentspecifications4
Size 4.6"Hx2.4"Wx1.2"D(118x60x30mm)
Weight 7.76oz.(220g)
Sensor Over20intelligentinterchangeablefield-replaceableelectrochemicalsensors
BatteryRechargeableLi-ionbattery-Operatingtime:>30hours(normaloperation,non-wireless)-Rechargetime:<4hoursthroughchargingcradle
DisplayGraphicalLCDdisplaywithwhiteLEDbacklighting(activatedwhenmonitorisinalarmorwithabuttonpress)
DisplayReadout-Real-timereadingofgasconcentrationsinpartspermillion(ppm)ormg/m3;batterystatus;dataloggingon/off;wirelesson/offandreceptionquality
-STEL,TWA,andpeakvalues
Keypad 2buttonsforoperationandprogramming
Sampling Diffusion
Calibration AutomaticwithAutoRAE2TestandCalibrationSystem2ormanual
AlarmModes-Wirelessremotealarmnotification;audible(95dB@30cm),vibration,visiblealarm(flashingbrightredLEDs),andon-screenindicationofalarmconditions.
-ManDownAlarmwithpre-alarmandreal-timeremotewirelessnotification
Datalogging-Continuousdataloggingwithathree-monthcapacity(atone-minuteintervals)-User-configurabledatalogginginterval(from1to3,600seconds)
CommunicationandDataDownload
-Datadownloadandinstrumentset-uponPCviachargingandPCcomm.cradle
-DatadownloadviaAutoRAE2AutomaticTestandCalibrationSystem
-Wirelessdataandstatustransmission1viabuilt-inRFmodem(optional)
WirelessNetworkProRAEGuardianReal-TimeWirelessSafetySystemorClosed-LoopNetworkwiththeEchoViewHost
WirelessFrequency ISMlicense-freebands
WirelessRange(Typical)ToxiRAEProtoMeshRouter,EchoViewHost,orMeshReader2~330feet(100meters)ToxiRAEProtoRAELink3MeshorRAELink3Z1Meshmodems~33feet(10meters)
OperatingTemperature -4°to131°F(-20°to55°C)
Humidity 0%to95%relativehumidity(non-condensing)
DustandWaterResistanceIP-65ratingfordustandwateringressprotection(validatedbyanindependenttestlaboratory)
HazardousLocationApprovals
CSA: ClassI,Division1,GroupsA,B,CandD.T-codeT4 ClassI,Zone0A/ExiaIICT4ATEX: , II1G,ExiaIICGaT4IECEx: ExiaIICGaT4ChinaEx: ExiaIICT4
CECompliance(EuropeanConformity) EMCdirective:2004/108/EC.R&TTEdirective:1999/5/EC.ATEXdirective:94/9/EC
Warranty-Twoyearsonnon-consumablecomponentsandCO,H2S,andO2sensors-Oneyearonallothersensors,battery,andotherconsumableparts
1 WirelessunitshaveafunctioningRFmodemandarereadyforwirelessdeployments;non-wirelessunitscannotbeupgradedtowireless.Additionalequipmentand/orsoftwarelicensesmayberequiredtoenableremotewirelessmonitoringandalarmtransmission.
2 ContactRAESystemsforavailability.3 RAESystemsrecommendscalibratingsensorsoninstallation.4 Specificationsaresubjecttochange.
sensorspecifications4sensor Range Resolution
Ammonia(NH3) 0to100ppm 1ppm
CarbonMonoxide(CO)CarbonMonoxide(CO),Ext.RangeCarbonMonoxide(CO),H2-comp.
0to500ppm0to2,000ppm0to2,000ppm
1ppm10ppm10ppm
Chlorine(Cl2) 0to50ppm 0.1ppm
ChlorineDioxide(ClO2) 0to1ppm 0.03ppm
EthyleneOxide(EtO-A)EthyleneOxide(EtO-B)EthyleneOxide(EtO-C),Ext.Range
0to100ppm0to10ppm0to500ppm
1ppm0.1ppm10ppm
Formaldehyde(HCHO) 0to10ppm 0.05ppm
Hydrogen(H2) 0to1,000ppm 2ppm
HydrogenCyanide(HCN) 0to50ppm 0.5ppm
HydrogenSulfide(H2S)HydrogenSulfide(H2S),Ext.Range
0to100ppm0to1,000ppm
0.1ppm1ppm
MethylMercaptan(CH3-SH) 0to10ppm 0.1ppm
NitricOxide(NO) 0to250ppm 0.5ppm
NitrogenDioxide(NO2) 0to20ppm 0.1ppm
Oxygen(O2) 0to30%Vol. 0.1%Vol.
Phosphine(PH3)Phosphine(PH3),Ext.Range
0to20ppm0to1,000ppm
0.1ppm1ppm
SulfurDioxide(SO2) 0to20ppm 0.1ppm
www.raesystems.com
cORpORAtEhEADquARtERsRAEsystems,inc.3775NorthFirstStreetSanJose,[email protected]
WORLDWiDEsALEsOFFicEsusA/canada 1.877.723.2878Europe +45.86.52.51.55MiddleEast +00971.4.440.5949china +86.10.5885.8788-3000Asiapacific +852.2669.0828
Page 3
Personal Wireless Monitor For Combustible Gases and Vapors
The ToxiRAE Pro LEL is the world’s first personal wireless combustible gas monitor. The ToxiRAE Pro LEL provides safety professionals with wireless remote access to real-time instrument readings and alarm status for better visibility and faster incident response1. The ToxiRAE Pro LEL quickly detects and accurately monitors combustibles in concentrations from 0 to 100% of the lower explosive limit (LEL). With the most extensive onboard gas library in its class, the ToxiRAE Pro LEL can be programmed to automatically read in %LEL of the specified compound.
• Wirelesselevatessafetytothenextlevel
• ManDownAlarmwithreal-timeremotewirelessnotification
• Easytomaintainwithreplaceablesensor,filter,andLi-ionbattery
• Fully-automaticbumptestingandcalibrationwithAutoRAE22
KEyFEAtuREs
Wireless. Personal. Proven.
•Wirelessaccesstoreal-timeinstrumentreadingsandalarmstatusfromanylocation
•Unmistakablefive-waylocalandremotewirelessnotificationofalarmconditions
•55built-inLELcorrectionfactors
•Largestdisplayinitsclass
•Reliable,rugged,andintrinsicallysafe
•Continuousdatalogging
•Easytouse
AppLicAtions
•Construction
•Foundries
•Oilandgas
•Pharmaceutical
•Steelmills
•Utilities
•Waterandwastewater
•Welding/hotwork
The world’s first personal wireless combustible gas monitor protects workers without getting in the way
ToxiRAE Pro LEL
R
USC
Page 4
oRDERinginFoRMAtion(MoDEL:pgM-1820)• Wirelessornon-wirelessversionsareavailable1
• Bulkpackagesof10unitsareavailable• RefertothePortablesPricingGuideforpartnumbersformonitors,accessories,maintenancekits,gas,sensors,andreplacementparts
spEciFicAtions3
ToxiRAE ProPersonal Wireless Monitor for Combustible Gases and Vapors
DS-1065-04
toxiRAEpRoLELsingLE-pAcKcoMEsWith:• ToxiRAEProLELmonitorwithsensor,alligatorclip,
protectiverubberboot,andrechargeablebatteryinstalled• ChargingandPCcommunicationcradle• PCcommunicationcable• ACadapter(100to240V,50/60HzACto12VDC)• Calibrationadapters• QuickStartGuide• CDwithdocumentation• ProRAEStudioIIsoftwareforPC-basedinstrumentconfigurationanddatamanagement
• Calibrationcard,qualitycertificate,andwarranty/registrationcard
optionALAccEssoRiEs• AutoRAE2AutomaticTestandCalibrationSystem• Multi-unitchargingstationforuptofivemonitors
Size 4.6"Hx2.4"Wx1.2"D(118x60x30mm)
Weight 8.29oz.(235g.)
SensorCatalyticbeadLELsensorwith0to100%LELrangeand1%LELresolution.Responsetime(T90)<15seconds
DetectableGasesCombustiblegasesandvaporsfrompaints,coatings,fuels,degreasers,adhesives,solvents,resins,etchers,inks,pesticides,herbicides,etc.using55onboardcorrectionfactors
BatteryRechargeableLi-ionbattery-Operatingtime:>12hours(normaloperation,non-wireless)-Rechargetime:<4hoursthroughchargingcradle
DisplayGraphicalLCDdisplaywithwhiteLEDbacklighting(activatedwhenmonitorisinalarmorwithabuttonpress)
DisplayReadout-Real-timereadingof%oflowerexplosivelimit(LEL);batterystatus;dataloggingon/off;wirelesson/offandreceptionquality-Peakvalues
Keypad 2buttonsforoperationandprogramming
Sampling Diffusion
Calibration AutomaticwithAutoRAE2TestandCalibrationSystem2ormanual
AlarmModes-Wirelessremotealarmnotification1;audible(95dB@30cm),vibration,visiblealarm(flashingbrightredLEDs),andon-screenindicationofalarmconditions-ManDownAlarmwithpre-alarmandreal-timeremotewirelessnotification
DataloggingContinuousdataloggingwithathree-monthcapacity(atone-minuteintervals)-User-configurabledatalogginginterval(from1to3,600seconds)
CommunicationandDataDownload
-Datadownloadandinstrumentset-uponPCviachargingandPCcomm.cradle-DatadownloadviaAutoRAE2AutomaticTestandCalibrationSystem2
-Wirelessdataandstatustransmissionviabuilt-inRFmodem(optional)
WirelessNetworkProRAEGuardianReal-TimeWirelessSafetySystemorClosed-LoopNetworkwiththeEchoViewHost
WirelessFrequency ISMlicense-freebands
WirelessRange(Typical)ToxiRAEProLELtoMeshRouter,EchoViewHost,orMeshReader2~330feet(100meters)ToxiRAEProLELtoRAELink3MeshorRAELink3Z1Meshmodems~33feet(10meters)
OperatingTemperature -4°to122°F(-20°to50°C)
Humidity 0%to95%relativehumidity(non-condensing)
DustandWaterResistance IP-65ratingfordustandwateringressprotection(validatedbyanindependenttestlaboratory)
HazardousLocationApprovals
CSA: ClassI,Division1,GroupsA,B,CandD.T-codeT4 ClassI,Zone0A/ExiaIICT4ATEX: , II1G,ExiaIICGaT4IECEx: ExiaIICGaT4ChinaEx: ExiaIICT4
CECompliance(EuropeanConformity)
EMCdirective:2004/108/EC.R&TTEdirective:1999/5/EC.ATEXdirective:94/9/EC
PerformanceTestComplianceC22.2No152ANSI/ISA-12.13.01
Warranty-TwoyearsontheLELsensorandnon-consumablecomponents-Oneyearonbatteryandotherconsumableparts
1 WirelessunitshaveafunctioningRFmodemandarereadyforwirelessdeployments;non-wirelessunitscannotbeupgradedtowireless.Additionalequipmentand/orsoftwarelicensesmayberequiredtoenableremotewirelessmonitoringandalarmtransmission.
2 ContactRAESystemsforavailability.3 Specificationsaresubjecttochange.
LEL
www.raesystems.com
coRpoRAtEhEADquARtERsRAEsystems,inc.3775NorthFirstStreetSanJose,[email protected]
WoRLDWiDEsALEsoFFicEsusA/canada 1.877.723.2878Europe +45.86.52.51.55MiddleEast +00971.4.440.5949china +86.10.5885.8788-3000Asiapacific +852.2669.0828
Page 5
Personal Wireless Monitor For Volatile Organic Compounds
The ToxiRAE Pro PID is the world’s smallest volatile organic compound (VOC) monitor. Featuring RAE Systems’ next-generation PID sensor, the ToxiRAE Pro PID can quickly detect and accurately monitor over 300 VOCs. The ToxiRAE Pro PID provides safety professionals wireless remote access to real-time instrument readings and alarm status for better visibility and faster incident response1. With an onboard library of 190 correction factors, the ToxiRAE Pro PID can be programmed to automatically read in equivalent units of the specified compound.
• Wirelesselevatessafetytothenextlevel
• AvailableinIndustrialHygiene(advanced)orSafety(basic)configurations
• ManDownAlarmwithreal-timeremotewirelessnotification
• Easytomaintainwithreplaceablesensor,fan,filter,andbattery
• FullyautomaticbumptestingandcalibrationwithAutoRAE22
KEyFEAtuRES
Wireless. Personal. Proven.
•Wirelessaccesstoreal-timeinstrumentreadingsandalarmstatusfromanylocation
•Unmistakablefive-waylocalandremotewirelessnotificationofalarmconditions
•Largestdisplayinitsclass
•Continuousdatalogging3
•On-boardcorrectionfactorlibraryfor190compounds
•Easytouse
•Reliable,rugged,andintrinsicallysafe
ApplIcAtIonS
•Industrialhygieneandsafety
– Chemicalplants
– Governmenthealth,safety,security,andenvironmentalagencies
– Hazardousmaterialsteams,firstresponders
– Oilandgas
– Pharmaceuticalplants
•Environmentalapplications
– Environmentalconsulting
– Soilremediation
ToxiRAE Pro PID
R
USC
Worker exposure monitoring with ToxiRAE Pro PID at a PVC plant
Page 6
oRDERIngInFoRMAtIon(MoDEl:pgM-1800)• IndustrialHygiene(advanced)andSafety(basic)configurationsareavailable
IndustrialHygieneconfigurations: –AdvancedPIDsensor(0.1to2,000ppm; 0.1ppmresolution)
–Datalogging –9.8eVor10.6eVlampoptions
Safetyconfigurations: – 10.6eV;1to1,000ppm;1ppmresolutionPID – Nodatalogging – 10.6eVlamponly
• Wirelessornon-wirelessversionsareavailable1
• RefertothePortablesPricingGuideforpartnumbersformonitors,accessories,maintenancekits,gas,sensors,andreplacementparts
SpEcIFIcAtIonS4
ToxiRAE ProPersonal Wireless Monitor for Volatile Organic Compounds
DS-1063-04
toxIRAEpRopIDcoMESWItH:• ToxiRAEProPIDmonitorwithsensorasspecified,alligatorclip,protectiverubberboot,andrechargeablebatteryinstalled
• ChargingandPCcommunicationcradle
• PCcommunicationcable
• ACadapter(100to240V,50/60HzACto12VDC)
• Calibrationadapter
• Combinedinstrument/sensorcapremovaltool
• QuickStartGuide
• CDwithdocumentation
• ProRAEStudioIIsoftwareforPC-basedinstrumentconfigurationanddatamanagement
• TechnicalNoteTN-106withionizationenergiesandcorrectionfactorsfor300+VOCs3
• Calibrationcard;qualitycertificate;andwarranty/registrationcard
optIonAlAccESSoRIES• AutoRAE2AutomaticTestandCalibrationSystem
• Multi-unitchargingstationforuptofivemonitors
Size 4.6"Hx2.4"Wx1.2"D(118x60x30mm)
Weight 8.29oz.(235g.)
SensorPhotoionizationsensorwith10.6eV(standard)or9.8eV2,3(optional)lamp.Responsetime(T90)<15sec.(Isobutene).Field-replaceablesensor.Easyaccesstolampforcleaning
DetectableGases Awidevarietyofionizablechemicalsusing190built-inandover300publishedcorrectionfactors
BatteryRechargeableLi-ionbattery-Operatingtime:>12hours(normaloperation,non-wireless)-Rechargetime:<4hoursthroughchargingcradle
DisplayGraphicalLCDdisplaywithwhiteLEDbacklighting(activatedwhenmonitorisinalarmorwithabuttonpress)
DisplayReadout-Real-timereadingofVOCconcentrationsinpartspermillionormg/m3;batterystatus;dataloggingon/off;wirelesson/offandreceptionquality-STEL,TWA,andpeakvalues
Keypad 2buttonsforoperationandprogramming
Sampling Internalfan
Calibration AutomaticwithAutoRAE2TestandCalibrationSystem2ormanual
AlarmModes-Wirelessremotealarmnotification1;audible(95dB@30cm),vibration,visiblealarm(flashingbrightredLEDs),andon-screenindicationofalarmconditions-ManDownAlarmwithpre-alarmandreal-timeremotewirelessnotification
Datalogging-Continuousdatalogging3withathree-monthcapacity(atone-minuteintervals)-User-configurabledatalogginginterval(from1to3,600seconds)
CommunicationandDataDownload
-Datadownloadandinstrumentset-uponPCviachargingandPCcomm.cradle-DatadownloadviaAutoRAE2AutomaticTestandCalibrationSystem-Wirelessdataandstatustransmission1viabuilt-inRFmodem(optional)
WirelessNetworkProRAEGuardianReal-TimeWirelessSafetySystemorClosed-LoopNetworkwiththeEchoViewHost
WirelessFrequency ISMlicense-freebands
WirelessRange(Typical)ToxiRAEProPIDtoMeshRouter,EchoViewHost,orMeshReader2~330feet(100meters)ToxiRAEProPIDtoRAELink3MeshorRAELink3Z1Meshmodems~33feet(10meters)
OperatingTemperature -4°to131°F(-20°to55°C)
Humidity 0%to95%relativehumidity(non-condensing)
HazardousLocationApprovals
CSA: ClassI,Division1,GroupsA,B,CandD.T-codeT4 ClassI,Zone0A/ExiaIICT4ATEX: , II1G,ExiaIICGaT4IECEx: ExiaIICGaT4ChinaEx: ExiaIICT4
CECompliance(EuropeanConformity)
EMCdirective:2004/108/EC.R&TTEdirective:1999/5/EC.ATEXdirective:94/9/EC
Warranty-Twoyearsonnon-consumablecomponents-Oneyearonsensor,fan,battery,andotherconsumableparts
1 WirelessunitshaveafunctioningRFmodemandarereadyforwirelessdeployments;non-wirelessunitscannotbeupgradedtowireless.Additionalequipmentand/orsoftwarelicensesmayberequiredtoenableremotewirelessmonitoringandalarmtransmission.
2 ContactRAESystemsforavailability.3 AvailablewithIndustrialHygieneconfigurationsonly.4 Specificationsaresubjecttochange.
PID
www.raesystems.com
coRpoRAtEHEADquARtERSRAESystems,Inc.3775NorthFirstStreetSanJose,[email protected]
WoRlDWIDESAlESoFFIcESuSA/canada 1.877.723.2878Europe +45.86.52.51.55MiddleEast +00971.4.440.5949china +86.10.5885.8788-3000Asiapacific +852.2669.0828
Page 7
Personal Wireless Monitor For Carbon Dioxide
The ToxiRAE Pro CO2 is the world’s first wireless personal carbon dioxide monitor. It provides safety professionals with wireless remote access to real-time instrument readings and alarm status for better visibility and faster incident response.
The ToxiRAE Pro offers datalogging capability and is equipped with a “Man Down” alarm and policy enforcement to ensure greater safety while making sure compliance-related procedures such as periodic testing and calibration are performed.
• Wirelessremotemonitoringenhancesworkersafety
• ManDownAlarmwithreal-timewirelessremotenotification
• Easytomaintain,withreplaceablesensor,filter,andLi-Ionbattery
• FullyautomaticbumptestingandcalibrationwithAutoRAE2
KEyFEAtuREs
Wireless. Personal. Proven.
•Wirelessaccesstoreal-timeinstrumentreadingsandalarmstatusfromanylocation
•Unmistakablefive-waylocalandremotewirelessnotificationofalarmconditions
•Intelligentsensorstorescalibrationdata,soitcanbeswappedinthefield
•Largestdisplayinitsclass
•Continuousdatalogging
•Easytouse
•Reliableandrugged
INDustRIEs
•Chemicalmanufacturing
•Foodandbeverage
•Wineriesandbreweries
•Landfills
•Waterandwastewaterfacilities
The world’s first personal wireless monitor for carbon dioxide
ToxiRAE Pro CO2
Page 8
spEcIFIcAtIoNs
ToxiRAE Pro CO2Personal Wireless Monitor For Carbon Dioxide
DS-1085-01
toxIRAEpRoco2coMEsWIth:
•ToxiRAEProCO2monitorwithsensorasspecified,alligatorclip,protectiverubberboot,andrechargeablebatteryinstalled
•ChargingandPCcommunicationcradle•PCcommunicationcable•ACadapter(100to240V,50/60HzACto12VDC)•Calibrationadapters•QuickStartGuide•CDwithdocumentation•ProRAEStudioIIsoftwareforPC-basedinstrumentconfigurationanddatamanagement
•Calibrationcard,qualitycertificate,andwarranty/registrationcard
optIoNALAccEssoRIEs
•AutoRAE2AutomaticTestandCalibrationSystem•Multi-unitchargingstationforuptofivemonitors
oRDERINgINFoRMAtIoN(MoDEL:pgM-1850)
•Wirelessornon-wirelessversionsareavailable1
•ContactyourlocalRAESystemsdistributorforpartnumbersformonitors,accessories,maintenancekits,gas,sensors,andreplacementparts
Size 4.6"Hx2.4"Wx1.2"D(118x60x30mm)Weight 7.76oz.(220g)Sensor Nondispersiveinfraredsensor
Range:0to50,000ppmResolution:100ppm
Battery RechargeableLi-ionbattery-Operatingtime:>11hours(normaloperation25˚C/77˚F,non-wireless)-Rechargetime:<4hoursthroughchargingcradle
Display GraphicalLCDdisplaywithwhiteLEDbacklighting(activatedwhenmonitorisinalarmorwithabuttonpress)
DisplayReadout -Real-timereadingofgasconcentrationsinpartspermillion(ppm);batterystatus;dataloggingon/off;wirelesson/off,andreceptionquality-STEL,TWA,andpeakvalues
Keypad 2buttonsforoperationandprogrammingSampling DiffusionCalibration AutomaticwithAutoRAE2TestandCalibrationSystemormanualAlarmModes -Wirelessremotealarmnotification;audible(95dB@30cm),vibration,
visiblealarm(flashingbrightredLEDs),andon-screenindicationofalarmconditions.-ManDownAlarmwithpre-alarmandreal-timeremotewirelessnotification
Datalogging -Continuousdataloggingwithathree-monthcapacity(atone-minuteintervals)-User-configurabledatalogginginterval(from1to3,600seconds)
CommunicationandDataDownload
-DatadownloadandinstrumentsetuponPCviachargingandPCcomm.cradle-DatadownloadviaAutoRAE2AutomaticTestandCalibrationSystem-Wirelessdataandstatustransmission1viabuilt-inRFmodem(optional)
WirelessNetwork ProRAEGuardianReal-TimeWirelessSafetySystemorClosed-LoopNetworkwiththeEchoViewHost
WirelessFrequency ISMlicense-freebandsWirelessRange(Typical)
ToxiRAEProtoMeshRouterorEchoViewHost~660feet(200meters)ToxiRAEProtoRAELink3MeshorRAELink3Z1Meshmodems~330feet(100meters)
OperatingTemperature -4°to131°F(-20°to55°C)Humidity 0%to95%relativehumidity(non-condensing)DustandWaterResistance
IP-65
HazardousLocationApprovals
Unitcannotbeusedinhazardousarea
CECompliance(EuropeanConformity)
EMCdirective:2004/108/EC.R&TTEdirective:1999/5/EC
Warranty -Twoyearsonnon-consumablecomponents-Oneyearonallothersensors,battery,andotherconsumableparts
1WirelessunitshaveafunctioningRFmodemandarereadyforwirelessdeployments.Non-wirelessunitscannotbeupgradedtowireless.Additionalequipmentand/orsoftwarelicensesmayberequiredtoenableremotewirelessmonitoringandalarmtransmission.
Specificationsaresubjecttochange.
www.raesystems.com
coRpoRAtEhEADquARtERsRAEsystems,Inc.3775NorthFirstStreetSanJose,CA95134USA
WoRLDWIDEsALEsoFFIcEsusA/canada 1.877.723.2878Europe +45.86.52.51.55MiddleEast +00971.4.440.5949china +86.10.5885.8788-3000Asiapacific +852.2669.0828
AutoRAE 2 with ToxiRAE Pro cradles