Download C.A.D models or contact us on COSSIGA.COM Page 1 TOWER COUNTER TOP STG STG RF6 STG RF9 STG RF12 STG RF15 STG HT6 STG HT9 STG HT12 RF Deck forced refrigeration Sliding doors front and rear Double glazed Two adjustable shelves Ticket strips on shelves and deck Undershelf and canopy LED lights Integral condensor Self evaporating Solid glass front - optional STG RF6 hinged rear door HT Sliding doors front and rear Single glazed Three adjustable shelves Ticket strips on shelves and deck Undershelf and canopy LED lights Solid glass front - optional STG HT6 hinged rear door
19
Embed
TOWER COUNTER TOP STG RF - Cossiga · STG ACCESSORIES Top Mounted Controller Panel Price Tabs 450 mm 450 mm Base Tray - Heated Units Tong Holder Bag Holder Humidity Dish 100 mm 190
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Download C.A.D models or contact us on COSSIGA.COMPage 1
TOWER COUNTER TOP STG
STG RF6STG RF9STG RF12STG RF15
STG HT6STG HT9STG HT12
RFDeck forced refrigerationSliding doors front and rearDouble glazedTwo adjustable shelvesTicket strips on shelves and deckUndershelf and canopy LED lightsIntegral condensorSelf evaporatingSolid glass front - optionalSTG RF6 hinged rear door
HTSliding doors front and rearSingle glazedThree adjustable shelvesTicket strips on shelves and deckUndershelf and canopy LED lightsSolid glass front - optionalSTG HT6 hinged rear door
Download C.A.D models or contact us on COSSIGA.COMPage 2
AB
BM
Sliding doors front and rearSingle glazedThree adjustable shelvesTicket strips on shelves and deckUndershelf and canopy LED lightsSolid glass front - optionalAmbient converted from heatedAir removal fan installed in ceilingSTG AB6 hinged rear door
Sliding doors front and rearOverhead halogen lightsWet / dry element in baseSingle glazed glassSolid glass front - optional
STG AB6STG AB9STG AB12
STG BM6STG BM9STG BM12
TOWER COUNTER TOP STG
Download C.A.D models or contact us on COSSIGA.COMPage 3
OHOpen front heatedSingle glazedIndividual shelf heating including baseTicket strips on shelves and baseUndershelf and canopy LED lights
STG OH6STG OH9
351
TOWER COUNTER TOP STG
Download C.A.D models or contact us on COSSIGA.COMPage 4
CABINET DIMENSIONS & SPECIFICATIONSMODEL CABINET SHELVING REFRIGERANT TOTAL
Fan 230v ~ 50Hz - 60Hz - 19 Watt in stainless steel case
EXTRACTION FAN
150 mm
Cut out see table
Cut out 585 mm
Cut out 620 mmmin 20 mm
min 20 mm
Cut out 525 mmmin 75 mm
min 75 mm
Condensor unit545w x 485d x 390h(RF6 485w x 485d x 335h)
Condensor unit545w x 485d x 390h(RF6 485w x 485d x 335h)
RF6 Cut out 525 mmRF6 Cut out 525 mm
ALLO
W 4
00 m
m
ALLO
W 4
00 m
m
Open at rear. Open at rear.
Supplied 5mm PVCwedge strip to sidesfor drop-in unit.
Remove feet for alldrop-in installations
Download C.A.D models or contact us on COSSIGA.COMPage 12
DROP IN COUNTER TOP CUT OUT DETAILS
Supplied 5mm PVCwedge strip to sidesfor drop-in unit.No glue or sealant required
Full bench top drop in On bench top drop in
benchtop cut out sizes
Download C.A.D models or contact us on COSSIGA.COMPage 13
JOINERY TO REAR WALL WITH VENT
Horizontal vent in cabinet top for hot air extract
Electric biscuit fans can also be fitted to provide mechanical extract
Ambient air ducted in to compressor face through air plenum space
Joinery divider panel providing sealed air intake plenum with cut out to meet condensor face
Allow access for cleaning, servicing and waste evaporator water removal
Ambient air is drawn into front vented area Hot air must escape joinery cabinet A horizontal vent should be used behind the unit
Vent must be at least 100mm deep and as wide as unit
Download C.A.D models or contact us on COSSIGA.COMPage 14
AIRFLOW AND PLACEMENT GUIDE LINES
Blocked air flow will retard operation on both HOT and COLD units
Ensure trays or plates are not blocking air flow at rear
CORRECT AIR FLOW INCORRECT AIR FLOW
CLEAR FLOW
NO AIR FLOW
AIR FLOW BLOCKED
too much chilled airaround coil can createexcessive ice build up
Heat from other equipment and natural conditions can cause cooling failures and overheating of compressors
Locations to avoid are :Close to shop front exterior In an outside location In direct sunlightIn a high cross wind areaNear any source producing excessive heatService units more frequently in dusty or polluted areas
Download C.A.D models or contact us on COSSIGA.COMPage 15
Ventilation Grill
STG ACCESSORIES
Top Mounted Controller Panel
Price Tabs
450
mm
450 mm
Base Tray - Heated Units
Tong Holder
Bag Holder
Humidity Dish
100 mm
190 mm
80 mm
180
mm
220 mm
190 mm
105 mm
75 mm
For against wall installationsSold individually
Stainless SteelWrite on with marker or adhesive tapeMeasure 60mm x 30mmSold in packs of 20
Stainless SteelSold individually
Stainless SteelDrop into counter tray raceSolid individually
Stainless SteelDrop into counter tray raceSold individually
Stainless SteelFor heated unitsSold in pairs
Stainless SteelPerforated lid is removable
Download C.A.D models or contact us on COSSIGA.COMPage 16
Price TabsLengths
Ticket Strip
Stainless SteelWrite on with marker or adhesive tapeMeasure 60mm x 30mmSold in packs of 20
Stainless SteelFits over front of shelves
CABINETLENGTH MM
TICKET STRIP LENGTH
600 475
900 775
1200 1075
1500 1375
End Profile
TICKET STRIP
Download C.A.D models or contact us on COSSIGA.COMPage 17
Applied to the inside glass rear doors
Suitable for heated and chilledunits
Mirror film adhered to inside of rear door glass
Mirror film adhered to inside of rear door glass
FREE STANDING UNITS BENCHTOP UNITS
Blocks work areasbehind units
Add depth toyour displays
MIRROR FILM
Download C.A.D models or contact us on COSSIGA.COMPage 18
Pie Trays
Stainless Steel ConstructionPlaced on shelves for heated food items