Installation Instructions PanelView Plus, VersaView CE Terminals and Display Modules 2711P and 6182H Inside... English....................................................... 3 Français ................................................... 19 Deutsch ................................................... 35 Español.................................................... 51 Italiano .................................................... 67 Português ................................................ 83
19

Touch Screen Installation Manual

Apr 06, 2018

Download

Documents

Mark Hrbek
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Touch Screen Installation Manual

8/3/2019 Touch Screen Installation Manual

http://slidepdf.com/reader/full/touch-screen-installation-manual 1/18

Publication 2711P-IN001C-MU-P

Installation Instructions 

PanelView Plus, VersaView CE Terminalsand Display Modules

2711P and 6182H

Inside...

English....................................................... 3Français................................................... 19

Deutsch ................................................... 35

Español.................................................... 51Italiano .................................................... 67

Português................................................ 83

Page 2: Touch Screen Installation Manual

8/3/2019 Touch Screen Installation Manual

http://slidepdf.com/reader/full/touch-screen-installation-manual 2/18

2 PanelView Plus, VersaView CE Terminals and Display Modules

Publication 2711P-IN001C-MU-P

Important User Information

Because of the variety of uses for the products described in this publication, those responsible for the

application and use of these products must satisfy themselves that all necessary steps have been taken to

assure that each application and use meets all performance and safety requirements, including any applicable

laws, regulations, codes and standards. In no event will Rockwell Automation be responsible or liable for

indirect or consequential damage resulting from the use or application of these products.

Any illustrations, charts, sample programs, and layout examples shown in this publication are intended solely

for purposes of example. Since there are many variables and requirements associated with any particular

installation, Rockwell Automation does not assume responsibility or liability (to include intellectual property

liability) for actual use based upon the examples shown in this publication.

Allen-Bradley publication SGI-1.1, Safety Guidelines for the Application, Installation and Maintenance of 

Solid-State Control (available from your local Rockwell Automation office), describes some important

differences between solid-state equipment and electromechanical devices that should be taken into

consideration when applying products such as those described in this publication.

Reproduction of the contents of this copyrighted publication, in whole or part, without written permission of

Rockwell Automation, is prohibited.

Throughout this publication, notes may be used to make you aware of safety considerations. The following

annotations and their accompanying statements help you to identify a potential hazard, avoid a potential

hazard, and recognize the consequences of a potential hazard:

!

 WARNINGIdentifies information about practices or circumstances that can cause an explosion in a

hazardous environment, which may lead to personal injury or death, property damage,

or economic loss.

ATTENTION

!Identifies information about practices or circumstances that can lead to personal injuryor death, property damage, or economic loss.

IMPORTANTIdentifies information that is critical for successful application and understanding of the

product.

Page 3: Touch Screen Installation Manual

8/3/2019 Touch Screen Installation Manual

http://slidepdf.com/reader/full/touch-screen-installation-manual 3/18

Publication 2711P-IN001C-MU-P

Installation Instructions 

PanelView Plus, VersaView CE Terminalsand Display Modules2711P and 6182H

English 

Inside:

Overview ..............................................................................................................................4

For More Information...........................................................................................................4

Modular Components ..........................................................................................................4Wiring and Safety Guidelines..............................................................................................5

Hazardous Locations............................................................................................................6

USB Ports .............................................................................................................................6

Environmental Considerations .............................................................................................8

Enclosures............................................................................................................................8

Clearances ...........................................................................................................................8

Required Tools......................................................................................................................8

Mounting Dimensions..........................................................................................................9

Cutout Dimensions.............................................................................................................11Installing Terminal in a Panel.............................................................................................11

Connecting DC Power ........................................................................................................13

European Communities (EC) Directive Compliance ...........................................................15

Product Specifications .......................................................................................................16

Page 4: Touch Screen Installation Manual

8/3/2019 Touch Screen Installation Manual

http://slidepdf.com/reader/full/touch-screen-installation-manual 4/18

4 PanelView Plus, VersaView CE Terminals and Display Modules

Publication 2711P-IN001C-MU-P

Overview

This document provides instructions on how to install the following devices in apanel or enclosure.

• factory assembled PanelView Plus or VersaView CE terminal

• PanelView Plus or VersaView CE Display Module

Refer to the installation instructions shipped with the Logic Module andCommunication Module for field installation of these components.

For More InformationTo obtain electronic versions of the PanelView Plus or VersaView CE User Manual, visit the following website:

 www.rockwellautomation.com/literature

Modular Components

The PanelView Plus and VersaView CE terminals have the following modularcomponents:

• Display Module (700/700H, 1000/1000H, 1250/1250H, 1500/1500H)

• Logic Module (DC Power, CF Card Slot, Ethernet Port, Serial Port, USB Ports)

• Internal Compact Flash card with firmware or operating system, RAMMemory (SO-DIMM)

• Communication Module (for specific communication protocols)

These items can be ordered as separate components for field installation or factory assembled per your configuration. The base configured unit includes the Display Module and the Logic Module (with Internal Compact Flash and RAM).

Communication Module

Logic Module

Display Module

DC Power Input

Ethernet Port

Serial PortUSB PortsCompact Flash Card Slot

Page 5: Touch Screen Installation Manual

8/3/2019 Touch Screen Installation Manual

http://slidepdf.com/reader/full/touch-screen-installation-manual 5/18

PanelView Plus, VersaView CE Terminals and Display Modules 5

Publication 2711P-IN001C-MU-P

If the modules are ordered separately, attach the Logic Module and CommunicationModule) to the Display Module before panel installation. See instructions shipped

 with each module.The Logic Module for both the PanelView Plus and VersaView CE is available withor without RAM and Compact Flash pre-installed. If ordered as separatecomponents, you must install the memory in the Logic Module before attaching theLogic Module to the Display Module. Refer to the installation instructions shipped with the Logic Module (2711P-IN004).

 Wiring and Safety GuidelinesUse publication NFPA 70E, "Electrical Safety Requirements for Employee Workplaces", IEC 60364 "Electrical Installations in Buildings" or other applicable wiring safety requirements for the country of installation when wiring the VersaView CE terminals. In addition to the NFPA guidelines:

• connect the terminal and other similar electronic equipment to its ownbranch circuit

• protect the input power by a fuse or circuit breaker rated at no more than 15

 Amps.• route incoming power to the terminal by a separate path from the

communication lines.

•  where power and communication lines must cross, they should cross at rightangles. Communication lines can be installed in the same conduit as lowlevel DC I/O lines (less than 10 volts).

• grounding minimizes noise from Electromagnetic Interference (EMI) and is asafety measure in electrical installations. To avoid EMI, shield and groundcables appropriately.

 A source for grounding recommendations is the National Electrical Code publishedby the National Fire Protection Association of Boston.

Page 6: Touch Screen Installation Manual

8/3/2019 Touch Screen Installation Manual

http://slidepdf.com/reader/full/touch-screen-installation-manual 6/18

6 PanelView Plus, VersaView CE Terminals and Display Modules

Publication 2711P-IN001C-MU-P

Hazardous Locations

This equipment is suitable for:• Class I, Division 2 Groups A, B, C, D• Class II, Division 2 Groups F, G• Class III• or (ordinary) non-hazardous locations only 

The following statement applies to use in hazardous locations.

The PanelView Plus and VersaView CE terminals have a temperature code of T4 when operating in a 55 °C (131 °F) maximum ambient temperature. Do not installthe terminals in environments where atmospheric gases have ignition temperaturesless than 135 °C (275 °F).

USB Ports

The PanelView Plus/VersaView CE terminals contain USB (Universal Serial Bus)ports which comply with hazardous location environments. This section details thefield wiring compliance requirements and is provided in accordance with theNational Electrical Code, article 500.

The USB peripheral device must be rated for use in the hazardous locationenvironment in which it is used and also comply with the circuit parameters inTable 2.

!

 WARNING Explosion Hazard 

• Substitution of components may impair suitability for

hazardous locations.

• Do not disconnect equipment unless power has beenswitched off and area is known to be non-hazardous.

• Do not connect or disconnect components unless powerhas been switched off.

•  All wiring must comply with N.E.C. articles 501-4(b),502-4(b), 503-3(b) as appropriate.

• Peripheral equipment must be suitable for the location it is

used in.

USB

Peripheral

Device

Associated Nonincendive FieldWiring Apparatus

USB Port

Page 7: Touch Screen Installation Manual

8/3/2019 Touch Screen Installation Manual

http://slidepdf.com/reader/full/touch-screen-installation-manual 7/18

PanelView Plus, VersaView CE Terminals and Display Modules 7

Publication 2711P-IN001C-MU-P

The circuit parameters in Table 1 define the maximum voltage and current of thePanelView Plus/VersaView CE USB ports.

The circuit parameters in Table 2 define the maximum voltage, current, capacitance,

and inductance values for any peripheral device connected to a PanelViewPlus/VersaView CE USB port in a hazardous location environment.

Application Information 

Per the National Electrical Code, the circuit parameters of associated field wiredapparatus for use in hazardous locations shall be coordinated with the host productsuch that their combination remains nonincendive. The PanelView Plus/VersaViewCE terminal and the USB peripheral device shall be treated in this manner.

The circuit parameters of the PanelView Plus/VersaView CE USB ports are given in

Table 1. The USB peripheral device and its associated cabling shall have circuitparameters with the limits given in Table 2 for them to remain nonincendive whenused with the PanelView Plus/VersaView CE USB ports. If cable compliance andinductance are not known, use the following values from UL 913:

Ccable = 60 pF/ft

Lcable = 0.20 µH/ft

Table 1 PanelView Plus/VersaView CE USB Port Circuit Parameters

Parameter Value Parameter Definition

V oc 5.25V dc Open circuit voltage of the host USB port.

I sc 1.68 A Maximum output current of the host USB port.

Table 2 Required Circuit Parameters for the USB Peripheral Device

Parameter Value Parameter Definition and Application Requirement

V max 5.25V dc Maximum applied voltage rating of the USB peripheral device.Vmax shall be greater than or equal to Voc in Table 2.1. (Vmax ≥ Voc )

I max 1.68 A Maximum current to which the USB peripheral device can be subjected.

I max shall be greater than or equal to Isc in Table 2.1.(Imax ≥  Isc)

C a 10 µF Maximum allowed capacitance of the USB peripheral device and itsassociated cable. The sum of Cint of the USB peripheral device andCcable of the associated cable shall be less than or equal to Ca.(Cint + Ccable ≤ Ca)

L a 15 µH Maximum allowed inductance of the USB peripheral device and itsassociated cable. The sum of Lint of the USB peripheral device andLcable of the associated cable shall be less than or equal to La.

(Lint + Lcable ≤ La)

Page 8: Touch Screen Installation Manual

8/3/2019 Touch Screen Installation Manual

http://slidepdf.com/reader/full/touch-screen-installation-manual 8/18

8 PanelView Plus, VersaView CE Terminals and Display Modules

Publication 2711P-IN001C-MU-P

Environmental Considerations

The terminals are suitable for use in an industrial environment when installed inaccordance with these instructions. Specifically, this equipment is intended for use

in clean, dry environments (Pollution Degree 2(1) and with circuits not exceeding

Over Voltage Category II (2) (IEC 60664-1).(3)

(1) Pollution Degree 2 is an environment where, normally, only non-conductive pollution occurs except that occasionally atemporary conductivity caused by condensation shall be expected.

(2) Over Voltage Category II is the load level section of the electrical distribution system. At this level transient voltages arecontrolled and do not exceed the impulse voltage capability of the product’s insulation.

(3) Pollution Degree 2 and Over Voltage Category II are International Electrotechnical Commission (IEC) designations.

Enclosures

The terminals must be mounted in a panel or enclosure to protect the internal

circuitry. The terminals meet NEMA Type 12/13 and 4X ratings only when mountedin a panel or enclosure with the equivalent rating.

 When the terminal is not mounted in a panel, it is not secure or safe for operation. You must comply with the NEMA Type 4 requirements for environmentalspecifications.

Clearances

 Allow adequate clearances around the terminal, inside the enclosure, for adequate ventilation. Consider heat produced by other devices in the enclosure. The ambient

temperature around the terminals must be between 0…55 °C (32…131 °F).Minimum clearances for ventilation are:

• top and bottom clearance: 51 mm (2 in)

• side clearances: 25 mm (1 in)

Maximum side clearance for insertion of memory card is 102 mm (4 in).

Required ToolsBesides the tools required for the panel or enclosure cutouts, you will need thefollowing for installation:

• small slotted screw driver

• torque wrench (in-lb)

Page 9: Touch Screen Installation Manual

8/3/2019 Touch Screen Installation Manual

http://slidepdf.com/reader/full/touch-screen-installation-manual 9/18

PanelView Plus, VersaView CE Terminals and Display Modules 9

Publication 2711P-IN001C-MU-P

Mounting Dimensions

This section provides mounting dimensions for the PanelView Plus and VersaViewCE terminals. The depth dimensions are shown for the:

• base configured unit (Display Module and Logic Module)

• base configured unit with Communication Module

 All measurements are in mm (inches).

To provide a frame of reference, the illustration following the table showsdimensions for the 1000/1000H terminals.

Terminal Type Height Width Depth

PanelView Plus 700/VersaView CE 700H

Keypad or Keypad & Touch193 (7.58) 290 (11.40)

55 (2.18)

Display to Logic Module

83 (3.27)Display to Comm Module

PanelView Plus 700/VersaView CE 700H

Touch Screen179 (7.04) 246 (9.68)

PanelView Plus 1000/VersaView CE 1000H

Keypad or Keypad & Touch248 (9.77) 399 (15.72)

PanelView Plus 1000/VersaView CE 1000HTouch Screen

248 (9.77) 329 (12.97)

PanelView Plus 1250/VersaView CE 1250H

Keypad or Keypad & Touch282 (11.12) 416 (16.36)

PanelView Plus 1250/VersaView CE 1250H

Touch Screen282 (11.12) 363 (14.30)

PanelView Plus 1500/VersaView CE 1500H

Keypad or Keypad & Touch330 (12.97) 469 (18.46) 65 (2.55)

Display to Logic Module

93 (3.65)Display to Comm Module

PanelView Plus 1500/VersaView CE 1500HTouch Screen

330 (12.97) 416 (16.36)

Page 10: Touch Screen Installation Manual

8/3/2019 Touch Screen Installation Manual

http://slidepdf.com/reader/full/touch-screen-installation-manual 10/18

10 PanelView Plus, VersaView CE Terminals and Display Modules

Publication 2711P-IN001C-MU-P

PanelView Plus 1000 and VersaView CE 1000H

 All measurements are in mm (inches).

Keypad or

Keypad & Touch

Touch Screen

a 55 (2.18) Display to Logic Module

b 83 (3.27) Display to Comm Module

a 55 (2.18) Display to Logic Module

b 83 (3.27) Display to Comm Module

248

(9.77)

399

(15.72)

ba

b

a

329

(12.97)

248

(9.77)

Page 11: Touch Screen Installation Manual

8/3/2019 Touch Screen Installation Manual

http://slidepdf.com/reader/full/touch-screen-installation-manual 11/18

PanelView Plus, VersaView CE Terminals and Display Modules 11

Publication 2711P-IN001C-MU-P

Cutout Dimensions

The table below shows the overall cutout dimensions for each PanelView Plus and VersaView CE terminal. Dimensions are in mm (inches).

Use the full size template shipped with your terminal to mark the cutoutdimensions.

Installing Terminal in a Panel

 All of the PanelView Plus and VersaView CE terminals are installed in the samemanner using clips for mounting. The number of clips used (4, 6 or 8) varies by terminal type. The mounting clips are shipped with each terminal.

 To install terminal in a panel:1. Cut an opening in the panel using the panel cutout provided with the

terminal. Remove any sharp edges or burrs.

2. Make sure the terminal sealing gasket is properly positioned on the terminalas shown. This gasket forms a compression type seal. Do not use sealingcompounds.

PanelView Plus /VersaView CE Terminal Height Width

700/700H Keypad or Keypad & Touch 167 (6.57) 264 (10.39)

700/700H Touch 154 (6.08) 220 (8.67)

1000/1000H Keypad or Keypad & Touch 224 (8.8) 375 (14.75)

1000/1000H Touch 224 (8.8) 305 (12.00)

1250/1250H Keypad or Keypad & Touch 257 (10.11) 390 (15.35)

1250/1250H Touch 257 (10.11) 338 (13.29)

1500/1500H Keypad or Keypad & Touch 305 (12.00) 419 (16.50)

1500/1500H Touch 305 (12.00) 391 (15.40)

ATTENTION

!

• Disconnect all electrical power from the panel beforemaking the panel cutout.

• Make sure the area around the panel cutout is clear.

• Do not allow metal cuttings to enter any componentsalready installed in the panel.

• Failure to follow these instructions may result in personalinjury or damage to panel components.

Page 12: Touch Screen Installation Manual

8/3/2019 Touch Screen Installation Manual

http://slidepdf.com/reader/full/touch-screen-installation-manual 12/18

12 PanelView Plus, VersaView CE Terminals and Display Modules

Publication 2711P-IN001C-MU-P

3. If using keypad legend strips on keypad terminals, we recommend that youinstall the strips before installing the terminal. Be careful not to pinch legendstrip during installation.

4. Place the terminal in the panel cutout.

5. Install the mounting clips. The ends of the clips slide into the slots on theterminal.

6. Tighten the mounting clip screws by hand until the gasket seal contacts themounting surface uniformly.

Sealing Gasket

Mounting Clip Slot

Mounting Clip

Page 13: Touch Screen Installation Manual

8/3/2019 Touch Screen Installation Manual

http://slidepdf.com/reader/full/touch-screen-installation-manual 13/18

PanelView Plus, VersaView CE Terminals and Display Modules 13

Publication 2711P-IN001C-MU-P

7.  Alternately tighten the mounting clips screws to a torque of .90 - 1.1 N•m (8- 10 in-lb). Do not over-tighten. Below are recommended torque sequences.

Connecting DC Power

The PanelView Plus and VersaView CE terminals have an integrated power supply that operates on 24V dc. The electrical input ratings of the power supply are:

• 24V dc nominal (18…32V dc)

• 70 Watts maximum (2.9A @24V dc)

The power supply is internally protected against reverse polarity.

The input power, terminal block on the power supply is removable and supportsthe following wire sizes:

ATTENTION

!

Tighten the mounting clip screws to a torque of .90 - 1.1N•m (8 - 10 in-lb) to provide a proper seal and to preventpotential damage to the terminal. Allen-Bradley assumes noresponsibility for water or chemical damage to the terminalor other equipment within the enclosure because of improper installation.

 Wire Type Wire Size Terminal Block Screw Torque

Stranded #16 to #22 AWG.23 - .45 N•m (2 - 4 in-lbs)

Solid #18 to #22 AWG

8 Clips

1

2

3

4

5

6

7

86 Clips

24 6

51 3

4 Clips

1 4

3 2

Page 14: Touch Screen Installation Manual

8/3/2019 Touch Screen Installation Manual

http://slidepdf.com/reader/full/touch-screen-installation-manual 14/18

14 PanelView Plus, VersaView CE Terminals and Display Modules

Publication 2711P-IN001C-MU-P

The terminals using 24V dc power are EN 61131-2 Equipment Class II devices. 

 To connect DC power:

1. Secure the DC power wires to the terminal block screws.

2. Secure the Functional Earth (FE) ground wire to the terminal blockscrew.

3.  Apply 24V dc power to the terminal.

ATTENTION

!

Use a Class 2/SELV (Safety Extra-Low Voltage), isolated andungrounded power supply as input power to the terminals.This power source provides protection so that under nominaland single fault conditions, the voltage between conductorsand between conductors and Functional Earth/Protective Earthdoes not exceed a safe value.

  Functional Earth Ground

-  DC Negative

Logic Module with

DC Power Input

+ DC Positive

Page 15: Touch Screen Installation Manual

8/3/2019 Touch Screen Installation Manual

http://slidepdf.com/reader/full/touch-screen-installation-manual 15/18

PanelView Plus, VersaView CE Terminals and Display Modules 15

Publication 2711P-IN001C-MU-P

European Communities (EC) Directive Compliance

If this product has the CE mark it is approved for installation within the EuropeanUnion and EEA regions. It has been designed and tested to meet the followingdirectives.

EMC Directive

This product is tested to meet the Council Directive 89/336/EC ElectromagneticCompatibility (EMC) by applying the following standards, in whole or in part,documented in a technical construction file:

• EN 50081-2 EMC - Generic Emission Standard, Part 2 - IndustrialEnvironment

• EN 61000-6-2 EMC - Generic Immunity Standard, Part 2 - IndustrialEnvironment

This product is intended for use in an industrial environment.

Low Voltage DirectiveThis product is tested to meet Council Directive 73/23/EEC Low Voltage, by applying the safety requirements of EN 61131-2 Programmable Controllers, Part 2 -Equipment Requirements and Tests. For specific information required by EN61131-2, see the appropriate sections in this publication, as well as the Allen-Bradley publication Industrial Automation Wiring and Grounding GuidelinesFor Noise Immunity, publication 1770-4.1.

Open style devices must be provided with environmental and safety protection by 

proper mounting in enclosures designed for specific application conditions. SeeNEMA Standards publication 250 and IEC publication 529, as applicable, forexplanations of the degrees of protection provided by different types of enclosure.

Page 16: Touch Screen Installation Manual

8/3/2019 Touch Screen Installation Manual

http://slidepdf.com/reader/full/touch-screen-installation-manual 16/18

16 PanelView Plus, VersaView CE Terminals and Display Modules

Publication 2711P-IN001C-MU-P

Product Specifications

Electrical

DC Power

Input Voltage DC

Power Consumption DC

24V dc nominal (18…32V dc)

70 Watts maximum (2.9 A @24V dc)

Display

Display Type Color Active Matrix, Thin FilmTransistor (TFT), with

Liquid Crystal Display (LCD)

Display Size

700/700H

1000/1000H

1250/1250H

1500/1500H

6.5 in

10.4 in

12.1 in

15 in

Display Area (W x H)

700/700H

1000/1000H

1250/1250H1500/1500H

132 x 99 mm (5.2 x 3.9 in)

211 x 158 mm (8.3 x 6.2 in)

246 x 184 mm (9.7 in x 7.2 in)304 x 228 mm (12.0 x 9.0 in)

Display Resolution

700/700H

1000/1000H

1250/1250H

1500/1500H

640 x 480

640 x 480

800 x 600

1024 x 768

Touch Screen Analog Resistive

Environmental

Operating Temperature 0…55 °C (32…131 °F)

Storage Temperature -20…70 °C (-13…158 °F)

Vibration 10…57 Hz, 0.012 pk-pk displacement

57…500 Hz 2.0 g pk acceleration

Shock Operating 15 g at 11 ms

Shock Non-Operating 30 g at 11 ms

Relative Humidity 5…95% without condensation

Ratings NEMA Type 12, 13, 4X (indoor use only), IP54, IP65

Page 17: Touch Screen Installation Manual

8/3/2019 Touch Screen Installation Manual

http://slidepdf.com/reader/full/touch-screen-installation-manual 17/18

PanelView Plus, VersaView CE Terminals and Display Modules 17

Publication 2711P-IN001C-MU-P

Mechanical

Dimensions H x W x D (for base configured unit without communication module)

700/700H Keypad or Keypad & Touch 193 x 290 x 55 mm (7.58 x 11.40 x 2.18 in)

700/700H Touch 179 x 246 x 55 mm (7.04 x 9.68 x 2.18 in)

1000/1000H Keypad or Keypad & Touch 248 x 399 x 55 mm (9.77 x 15.72 x 2.18 in)

1000/1000H Touch 248 x 329 x 55 mm (9.77 x 12.97 x 2.18 in)

1250/1250H Keypad or Keypad & Touch 282 x 416 x 55 mm (11.12 x 16.36 x 2.18 in)

1250/1250H Touch 282 x 363 x 55 mm (11.12 x 14.30 x 2.18 in)1500/1500H Keypad or Keypad & Touch 330 x 469 x 65 mm (12.97 x 18.46 x 2.55 in)

1500/1500H Touch 330 x 416 x 65 mm (12.97 x 16.36 x 2.55 in)

 Weight (for base configured unit without communication module)

700/700H Keypad or Keypad & Touch 1.9 kg (4.2 lb)

700/700H Touch 1.7 kg (3.8 lb)

1000/1000H Keypad or Keypad & Touch 2.9 kg (6.3 lb)

1000/1000H Touch 2.6 kg (5.7 lb)

1250/1250H Keypad or Keypad & Touch 3.4 kg (7.6 lb)

1250/1250H Touch 3.2 kg (7.1 lb)

1500/1500H Keypad or Keypad & Touch 4.6 kg (10.0 lb)

1500/1500H Touch 4.2 kg (9.3 lb)

Agency Certifications

When product is marked:

N223

Marked for all applicable directives

Marked for all applicable acts

UL Listed Industrial Control EquipmentUL Listed Industrial Control Equipment for use inCanadaUL Listed Industrial Control Equipment for use in• Class I, Div 2, Group A, B, C, D

• Class II, Div 2 Groups F, G

• Class III Hazardous Locations