www.geni-uv.com Total Solutions of UV Sensing Genicom Co., Ltd. Daehan Building 5F, #1018 Dunsan-dong, Seo-gu, Daejeon 302-120, Korea Tel :+82-42-862-3982 Fax :+82-42-862-2982 E-mail :[email protected] http://www.geni-uv.com
www.geni-uv.com
Total Solutions of UV SensingGenicom Co., Ltd.Daehan Building 5F, #1018 Dunsan-dong, Seo-gu, Daejeon 302-120, KoreaTel :+82-42-862-3982 Fax :+82-42-862-2982E-mail :[email protected] http://www.geni-uv.com
Model Numbering of the Probe
03
Total So
lutio
ns o
f UV
Sensin
g
ToTal SoluTionS
of uV SenSing
Model Numbering of ComponentCompany Introduction
G UVA - T1 1 G D - L① ② ③ ④ ⑤ ⑥ ⑦
① Manufacture - G : Genicom Co., Ltd.
② Detection Range - VGR : ~ 510 - VBL : ~ 470 - UVV : ~ 395 - UVA : ~ 370 - UVB : ~ 320 - UVC : ~ 280
③ Package Form - S1 : SMD3528 - S2 : SMD1608 - S3 : SMD3020 - T1 : TO-46 - T2 : TO-39 & TO5
④ Characteristics - from 0 to 9 - or from A to Z
⑤ Window Type - G : Quartz Glass - S : Si-encapsulant - E : Epoxy
⑥ Product Type - D : Discrete - H : Hybrid
⑦ Chip Size - Skip : 0.4 × 0.4 - L : 1.4 × 1.4 - U : 3.4 × 3.4
2010 May 2010 | Supplier for Samsung Electronics
2006 May 2006 | Development of InGaN-based UVA SensorFeb. 2006 | Acquisition of ISO14001 Certificate
2009 Sep. 2009 | Development portable UV radiometer
(CE Certificate)Mar. 2009 | Development of AlGaN-based Filter
2005 Oct. 2005 | Development of AlGaN-based UVC SensorMay 2005 | Supplier for LG Electronics
2008 Dec. 2008 | Development of UVC Probe
2004 Nov. 2004 | Acquisition of ISO9001 Certificate
May 2004 | Initiation of Sensor Business
2007 Dec. 2007 | Development of UV Radiometer
(CE Certificate)May 2007 | Acquisition of CE Certificate
(Outdoor UVI meter)
2000 Jul. 2000 | Establishment
Company History
Greetings from CEO
“We walk the path together!”
Since its foundation, Genicom Co., Ltd. has grown into a total solution specialist in
ultraviolet ray detection technology and products on the back of specialized GaN-based
technology and is doing its utmost to emerge as a global sensor specialist by developing
various detection and application technologies related to environment. In particular, it aims
to create a beautiful company by continuously improving technologies and services and
giving back to the society so that human beings can lead a pleasant life in harmony with the
environment and both customers and business partners can feel happy.
Thank you.
Package Dimension
04
Total So
lutio
ns o
f UV
Sensin
g
05
Total So
lutio
ns o
f UV
Sensin
g
Operation Information
S1 (SMD3528 )
S2 (SMD1608 )
S3 (SMD3020)
T1 (TO-46)
T2 (TO39)
T2 (TO5)
Absolute Maximum Ratings
Parameter Symbol Min. Max. Unit Remark
Storage Temperature Tst -40 90
Operating Temperature Top -30 85
Reverse Voltage Vr, max.
5 V
Forward Current If,max.
1
Soldering Temperature Tsol
260 within 10 sec.
Application Circuit
Name Part No. Function Model or Value Remark
OP-Amp OP-Amp AmplificationMCP6241LMC6081OPA237
Supply VoltageMCP6241 : 1.8 ~ 5.5 VLMC6081 : 4.5 ~ 15 VOPA237 : 2.7 ~ 36 V
Capacitor CDecreasing the input
noise10
Capacitor controls response time.If you want fast response, reduce the
capacitor like 1 or 10 .
Resistor R Gain control few Vout (V)= Iph (A) × R
06
Total So
lutio
ns o
f UV
Sensin
g
07
Total So
lutio
ns o
f UV
Sensin
g
GVGR-S10SD
Features SMD3528 with Si-encapsulantIndium Gallium Nitride Based MaterialPhotovoltaic Mode OperationHigh Responsivity & Low Dark Current
Applications UV LED Monitoring (385, 405nm, etc.)Blue LED MonitoringUVA Lamp Monitoring
Characteristics (at 25)
Parameter Symbol Min. Typ. Max. Unit Test Conditions
Dark Current Id 1 Vr = 0.1 V
Photo Current Iph 28 LED (405), 1/
Temperature Coefficient Tc -0.08 %/
Responsivity R 0.08 A/W λ= 405 , Vr = 0 V
Detection Range λ 300 510 10% of R
GVBL-S11SD
Features SMD3528 with Si-encapsulantIndium Gallium Nitride Based MaterialPhotovoltaic Mode OperationHigh Responsivity & Low Dark Current
Applications UV LED Monitoring (385, 405nm, etc.)Blue LED MonitoringUVA Lamp Monitoring
Characteristics (at 25)
Parameter Symbol Min. Typ. Max. Unit Test Conditions
Dark Current Id 1 Vr = 0.1 V
Photo Current Iph 48 LED (405), 1/
Temperature Coefficient Tc -0.09 %/
Responsivity R 0.11 A/W λ = 405 , Vr = 0 V
Detection Range λ 300 470 10% of R
GUVV-S10SD
Features Indium Gallium Nitride Based MaterialSchottky-type PhotodiodePhotovoltaic Mode OperationHigh Responsivity & Low Dark Current
Applications UV-A Lamp Monitoring
Characteristics (at 25)
Parameter Symbol Min. Typ. Max. Unit Test Conditions
Dark Current Id 1 Vr = 0.1 V
Photo Current Iph 181 UVA Lamp, 1/
Temperature Coefficient Itc 0.1 %/ UVA Lamp
Responsivity R 0.18 A/W λ = 350 , Vr = 0 V
Detection Range λ 240 395 10% of R
GUVV-T10GD
Features Indium Gallium Nitride Based MaterialSchottky-type PhotodiodePhotovoltaic Mode OperationHigh Responsivity & Low Dark Current
Applications Full UV Band MonitoringUV-A Lamp MonitoringSterilization Lamp Monitoring
Characteristics (at 25)
Parameter Symbol Min. Typ. Max. Unit Test Conditions
Dark Current Id 1 Vr = 0.1 V
Photo Current Iph 163 UVA Lamp, 1/
Temperature Coefficient Itc 0.1 %/ UVA Lamp
Responsivity R 0.12 A/W λ = 350 , Vr = 0 V
Detection Range λ 230 395 10% of R
UVA SensorVisible Sensor
08
Total So
lutio
ns o
f UV
Sensin
g
09
Total So
lutio
ns o
f UV
Sensin
g
UVB SensorUVA Sensor
GUVA-S12SD
Features Gallium Nitride Based MaterialSchottky-type PhotodiodePhotovoltaic Mode OperationGood Visible BlindnessHigh Responsivity & Low Dark Current
Applications UV Index MonitoringUV-A Lamp Monitoring
Characteristics (at 25)
Parameter Symbol Min. Typ. Max. Unit Test Conditions
Dark Current Id 1 Vr = 0.1 V
Photo Current Iph
113 UVA Lamp, 1/
26 1 UVI
Temperature Coefficient Itc 0.08 %/ UVA Lamp
Responsivity R 0.14 A/W λ = 350 , Vr = 0 V
Detection Range λ 240 370 10% of R
GUVA-T11GD
Features Gallium Nitride Based MaterialSchottky-type PhotodiodePhotovoltaic Mode OperationGood Visible BlindnessHigh Responsivity & Low Dark Current
Applications Full UV Band MonitoringUV-A Lamp MonitoringSterilization Lamp Monitoring
Characteristics (at 25)
Parameter Symbol Min. Typ. Max. Unit Test Conditions
Dark Current Id 1 Vr = 0.1 V
Photo Current Iph
161 UVA Lamp, 1/
93 UVC Lamp, 1/
Temperature Coefficient Itc 0.05 %/ UVA Lamp
Responsivity R 0.18 A/W λ = 350 , Vr = 0 V
Detection Range λ 220 370 10% of R
GUVB-S11SD
Features Aluminium Gallium Nitride Based MaterialSchottky-type PhotodiodePhotovoltaic Mode OperationGood Visible BlindnessHigh Responsivity & Low Dark Current
Applications UV Index Monitoring
Characteristics (at 25)
Parameter Symbol Min. Typ. Max. Unit Test Conditions
Dark Current Id 1 Vr = 0.1 V
Photo Current Iph
69 UVB Lamp, 1/
1.4 1 UVI
Temperature Coefficient Itc 0.1 %/ UVB Lamp
Responsivity R 0.14 A/W λ = 300 , Vr = 0 V
Detection Range λ 235 320 10% of R
GUVB-T11GD
Features Aluminium Gallium Nitride Based MaterialSchottky-type PhotodiodePhotovoltaic Mode OperationGood Visible BlindnessHigh Responsivity & Low Dark Current
Applications UV-B Lamp Monitoring
Characteristics (at 25)
Parameter Symbol Min. Typ. Max. Unit Test Conditions
Dark Current Id 1 Vr = 0.1 V
Photo Current Iph
76 UVB Lamp, 1/
1.7 1 UVI
Temperature Coefficient Itc 0.1 %/ UVB Lamp
Responsivity R 0.14 A/W λ = 300 , Vr = 0 V
Detection Range λ 220 320 10% of R
10
Total So
lutio
ns o
f UV
Sensin
g
11
Total So
lutio
ns o
f UV
Sensin
g
UV Sensor with Large Chip SizeUVC Sensor
GUVC-S30GD
Features Aluminium Gallium Nitride Based MaterialSchottky-type PhotodiodePhotovoltaic Mode OperationGood Solar Blindness
Applications Sterilization Lamp Monitoring
Characteristics (at 25)
Parameter Symbol Min. Typ. Max. Unit Test Conditions
Dark Current Id 1 Vr = 0.1 V
Photo Current Iph 34 UVC Lamp, 1/
Temperature Coefficient Itc -0.07 %/ UVC Lamp
Responsivity R 0.06 A/W λ = 254 , Vr = 0 V
Detection Range λ 210 280 10% of R
GUVC-T10GD
Features Aluminium Gallium Nitride Based MaterialSchottky-type PhotodiodePhotovoltaic Mode OperationGood Solar Blindness
Applications Pure UV-C MonitoringSterilization Lamp Monitoring
Characteristics (at 25)
Parameter Symbol Min. Typ. Max. Unit Test Conditions
Dark Current Id 1 Vr = 0.1 V
Photo Current Iph 34 UVC Lamp, 1/
Temperature Coefficient Itc -0.07 %/ UVC Lamp
Responsivity R 0.06 A/W λ = 254 , Vr = 0 V
Detection Range λ 210 280 10% of R
GUVx-T1xGD-L (TO46 package)
Applications UV LED / Lamp Monitoring
Characteristics (at 25)
Parameter UVA UVB UVC Unit Test Conditions
Dark Current 20 20 20 Vr = 0.1 V
Photo Current 3.1 1.5 0.55 1 /
Temperature Coefficient 0.05 0.1 -0.07 %/ UV Lamp
Responsivity 0.18 at 350 0.13 at 300 0.05 at 254 A/W Vr = 0 V
Detection Range 220~370 220~320 210 ~280 10% of R
GUVx-T2xGD-U (TO39 package)
Applications UV LED / Lamp Monitoring
Characteristics (at 25)
Parameter UVV UVA UVB UVC. Unit Test
Conditions
Dark Current 90 90 90 90 Vr = 0.1 V
Photo Current 14.7 15.6 7.4 3.3 1 /
Temperature Coefficient 0.15 0.05 0.1 -0.07 %/ UV Lamp
Responsivity 0.15 at 350 0.18 at 350 0.13 at 300 0.06 at 254 A/W Vr = 0 V
Detection Range 230~395 220~370 220~320 210~280 10% of R
GUVA-T11GD-L GUVB-T11GD-L GUVC-T10GD-L
GUVV-T20GD-U GUVA-T21GD-U GUVB-T21GD-U GUVC-T20GD-U
12
Total So
lutio
ns o
f UV
Sensin
g
Model Numbering of the Probe
13
Total So
lutio
ns o
f UV
Sensin
g
ToTal SoluTionS
of uV SenSing
Model Numbering of Probe and MeterUV sensor with Amplified Voltage Output
GUVx-T2xGH (TO5 package)
Features Single Supply Voltage & Voltage Output
Applications UV LED / Lamp Monitoring
Common Condition
Parameter Min. Typ. Max. Unit Remark
Storage Temperature -30 - 90
Operation Temperature -25 - 85
Supply Voltage 1.8 - 5.5 V DC
Supply Current - 50 -
Response Time - 5 -
Characteristics (at 25)
Model No. Detection Range ()
Detection Power Range (at Vcc=5V)
Output Voltage (at 1 /)
Vout Formula (V) Application
GUVV-T20GH 230 ~ 395 0 ~ 3.6 / 1.38V
(at 352 ) 1.38 × UVA power
(/) UV LED Monitoring
GUVA-T21GH 220 ~ 370 0 ~ 2.7 / 1.88 V
(at 352 ) 1.88 × UVA power
(/) UV Cure & UV-A Lamp monitoring
GUVB-T21GH 220 ~ 320 0 ~ 6.9 / 0.72 V
(at 306 ) 0.72 × UVB power
(/) UV-B Lamp Monitoring
GUVC-T21GH 220 ~ 280 0 ~ 13.3 / 0.355 V
(at 254 ) 0.355 × UVC power
(/) Sterilization Lamp
Monitoring
G UVC - T1 1 G C - 3 LW10① ② ③ ④ ⑤ ⑥ ⑦ ⑧
① Manufacture - G : Genicom Co., Ltd.
② Detection Range - UVV : ~ 395 - UVA : ~ 370 - UVB : ~ 320 - UVC : ~ 280
③ Package Form - S1 : SMD3528 - T1 : TO-46 - T2 : TO-39
④ Characteristics - from 0 to 9 ⑤ Window Type - G : Quartz Glass
⑥ Product Type - C : UV Sensor Probe - Sx : UV Meter ⑦ Chip Size & Module Version
⑧ Probe Type - LA : Air - LO : High Temperature - LW : Water - H : Outdoor
14
Total So
lutio
ns o
f UV
Sensin
g
15
Total So
lutio
ns o
f UV
Sensin
g
Monitor DimensionProbe Dimension
LA2 MG-05
MG-06
MG-04
MG-01
MG-02
H3
LW6.1
LW8
LW10
LO
LW5.0
LW9.1
LW11
HousingProbe
16
Total So
lutio
ns o
f UV
Sensin
g
17
Total So
lutio
ns o
f UV
Sensin
g
Selection Guide of Probe and Monitor UV Sensor Probe – LA & LO Series
GUVx-T1xGC-2LA2
Features Air environmentAnalog voltage output
Characteristics
Parameter Min. Typ. Max. Unit Remark
Supply Voltage 6 26 V DC
Supply Current 3.3
Detection Power Range 0 100 /
Product list
Model No. Detection Range Output Application
GUVV-T10GC-2LA2 230 ~ 395 0 ~ 5 VTotal UV Power Monitoring
UVA Lamp Monitoring
GUVB-T11GC-2LA2 220 ~ 320 0 ~ 5 V UVB Lamp monitoring
GUVC-T10GC-2LA2 220 ~ 280 0 ~ 5 VAir Sterilization,
UVC lamp monitoring
GUVx-T1xGC-xLO
Features High temperature environment (under 200)
Characteristics
Parameter Min. Typ. Max. Unit Remark
Supply Voltage 6 26 V DC
Operating Temperature Optical Fiber 200
LO Probe -30 85
Detection Power Range 0 1,000 /
Product list
Model No. Detection Range Output Application
GUVV-T11GC-3LO 230 ~ 395
0 ~ 5 VUV Cure, UVA Lamp monitoring
GUVV-T11GC-I2LO 4-20
GUVB-T12GC-3LO 220 ~ 320
0 ~ 5 V High power UVB monitoring
GUVB-T12GC-I2LO 4-20
GUVC-T11GC-3LO220 ~ 280
0 ~ 5 V Air Sterilization, UVC lamp monitoringGUVC-T11GC-I2LO 4-20
1. UV Sensor Probe Selection
1) Classification for wavelength of light source, Application - UVA region : UVV sensor ( 230 ~ 395 ), UV Cure ,UVA Lamp monitoring - UVB region : UVB sensor ( 220 ~ 320 ), UVB lamp monitoring - UVC region : UVC sensor ( 220 ~ 280 ), Sterilization Lamp monitoring
2) Classification for environment - LA series: Air environment under 80 - LO series: High temperature (under 200) - H Series : Outdoor UV sensor probe - LW series: Water Environment > Size : PT1/4” (LW5), PT3/4”(LW9 or LW10), NPT1/2”(LW8), PT1¼” (LW11) > Duplex interception : LW6 (with Housing)
3) Classification for output - Voltage Output (DC 0 – 5 V) : LA, LO, H3, LW5, LW9, LW10, LW11 - Current Output (4-20 ) : LO, H3, LW5, LW6, LW8, LW10, LW11
4) Operating Temperature & Response time
Parameter Min. Typ. Max. Unit Remark
Operating Temperature -30 85
200 LO Series
Response Time 5
2. Monitor Selection
Monitor Name
Display Output
Absolute Power
Relative Power
3 Color LED
Accumulative Time
Relay Voltage Current RS485
MG-05 O O O O O O
MG-06 O O O O
MG-04 O O O O O O
MG-01 O O O O O
MG-02 O O O O
18
Total So
lutio
ns o
f UV
Sensin
g
19
Total So
lutio
ns o
f UV
Sensin
g
UV Sensor Probe – H Series UV Sensor Probe – LW Series
GUVx-T1xGC-xLW5Features Water environment (10 bar), PT 1/ 4 ˝, STS 316-L
Characteristics
Parameter Min. Typ. Max. Unit Remark
Supply Voltage 6 26 V DC
Detection Power Range 0 100 /
Product list
Model No. Detection Range Output Application
GUVV-T11GC-3LW5 230 ~ 395
0 ~ 5 VUV Cure, UVA Lamp monitoring
GUVV-T11GC-I2LW5 4 - 20
GUVB-T12GC-3LW5 220 ~ 320
0 ~ 5 V UVB lamp monitoring
GUVB-T12GC-I2LW5 4 - 20
GUVC-T11GC-3LW5220 ~ 280
0 ~ 5 V Sterilization, UVC lamp monitoring
GUVC-T11GC-I2LW5 4 - 20
GUVx-T1xGC-xLW10Features Water environment (10 bar), PT 3 / 4 ˝, STS 316-L
Characteristics
Parameter Min. Typ. Max. Unit Remark
Supply Voltage 6 26 V DC
Detection Power Range 0 100 /
Product list
Model No. Detection Range Output Application
GUVV-T11GC-3LW10 230 ~ 395
0 ~ 5 VUV Cure, UVA Lamp monitoring
GUVV-T11GC-I2LW10 4 - 20
GUVB-T12GC-3LW10 220 ~ 320
0 ~ 5 V UVB lamp monitoring
GUVB-T12GC-I2LW10 4 - 20
GUVC-T11GC-3LW10220 ~ 280
0 ~ 5 VSterilization, UVC lamp monitoring
GUVC-T11GC-I2LW10 4 - 20
GUVA-S12SC-xH3Features Single supply voltage
Outdoor UV sensor probeOptical power check of sunlight
Characteristics
Parameter Min. Typ. Max. Unit Remark
Supply Voltage 6 26 V DC
Supply Current 3.3
Response Time 5
Product list
Model No. Detection
Range Output
Detection Power Range
Application
GUVA-S12SC-3LWH3 230 ~ 370
0 ~ 5 V 0~50 /
UVA power monitor of sunlight GUVA-S12SC-I2H3 4-20
GUVB-S11SC-3LWH3 220 ~ 320
0 ~ 5 V 0 ~ 20 UVI
UV index monitoring of sunlight GUVB-S11SC-I2H3 4-20
GUVB-S11GS-AG01.4Features This product is the Outdoor UV Index Meter
using UV sensor for UV Index. Option : Wireless Communication (Zigbee)
Physical Dimensions
Mechanical Data
Parameter Value Unit Remark
Operating Temperature -30 ~ 85
Weight 18 kg with bracket
Size Indicator 500 × 460 × 127
Solar Panel 547 × 360 × 25
Characteristics
Parameter Value Unit
UV Index display 0 ~ 11+ UVI
Delay Time 10 sec
20
Total So
lutio
ns o
f UV
Sensin
g
21
Total So
lutio
ns o
f UV
Sensin
g
UV Sensor Probe – LW SeriesUV Sensor Probe – LW Series
GUVC-T11GC-I6LW6Features Single supply voltage, 2 wire 4-20 current output Water environment (10 bar), with Housing
Applications Sterilization lamp monitoring Pure UV-C monitoring
Characteristics
Parameter Min. Typ. Max. Unit Remark
Supply Voltage 6 24 26 V DC
Offset Current 4
Spectral Detection Range 220 280 nm 10% of Max.
Output Current 4 20
Detection Power Range 0 100 /
GUVC-T11GC-I4LW8Features Single supply voltage, 3 wire 4-20 current output Water environment (10 bar), NPT ½”
Applications Sterilization lamp monitoring Pure UV-C monitoring
Characteristics
Parameter Min. Typ. Max. Unit Remark
Supply Voltage 6 24 26 V DC
Offset Current 4
Spectral Detection Range 220 280 nm 10% of Max.
Output Current 4 20
Detection Power Range 0 100 /
GUVx-T1xGC-5LW9Features Water environment (10 bar), PT 3 / 4 ˝, STS 316-L
Characteristics
Parameter Min. Typ. Max. Unit Remark
Supply Voltage 6 26 V DC
Detection Power Range 0 100 /
Product list
Model No. Detection Range Output Application
GUVV-T11GC-5LW9.1 230 ~ 395 0 ~ 5 V UV Cure, UVA Lamp monitoring
GUVB-T12GC-5LW9.1 220 ~ 320 0 ~ 5 V UVB lamp monitoring
GUVC-T11GC-5LW9.1 220 ~ 280 0 ~ 5 V Sterilization, UVC lamp monitoring
GUVC-T11GC-xLW11Features 4 Direction sensor probe Water environment (10 bar), PT 1 1 / 4 ˝, STS 316-L
Characteristics
Parameter Min. Typ. Max. Unit Remark
Supply Voltage 6 26 V DC
Detection Power Range 0 100 /
Product list
Model No. Detection Range Output Application
GUVC-T11GC-4LW11 220 ~ 320 0 ~ 5 V Sterilization, UVC lamp monitoring
GUVC-T11GC-I7LW11 220 ~ 280 4 - 20 Sterilization, UVC lamp monitoring
22
Total So
lutio
ns o
f UV
Sensin
g
23
Total So
lutio
ns o
f UV
Sensin
g
UV Monitor MG seriesUV Monitor MG series
MG-04 : GUVx-T1xGS4-xConstitution Monitor, Sensor Probe 3ea , Connection Cable 3ea
Description - 3 channel monitor with 3 color LED display - Display : Relative Power(%), Accumulative Time (hours), Absolute Power (/) - Output : Relay (COM, N/O/N/C, 250VAC 3A), 4-20 current (300 Ω max load)
Technology parameter
Operating temperature & humidity 0 ~ 50 , 35 ~ 85 %RH
Power Supply 85 ~ 265 VAC 50/60
Detection Power Range 0 ~ 100.00 /
Typical product : GUVC-T11GS4-3LW5.0, GUVC-T11GS4-LW9.1, GUVC-T11GS4-3LW10
MG-01 : GUVx-T1xGS-xConstitution Monitor, Sensor Probe, Output line, Adaptor
Description - 9V DC adaptor use - Display : Relative Power(%), Absolute Power (/), Accumulative Time (min), - Output : 0-5V DC voltage (0.1A max), 4-20 current (5V max)
Technology parameter
Operating temperature & humidity -15 ~ 65 , 35 ~ 85 %RH
Power Supply 9V DC 300 Adaptor (220V 50~60Hz)
Detection Power Range 0 ~ 9.99 / or 0 ~ 99.9 / or 0 ~ 999 /
Typical product : GUVV-T10GS-LA2, GUVC-T11GS-LA2, GUVC-T11GS-3LW10
MG-02 : GUVx-T1xGS2-xConstitution Monitor, Sensor Probe, Connection cable
Description - Display : Absolute Power (/) - Output : Relay (COM+N/O, COM+N/C), 4-20 current, RS485 communication
Technology parameter
Operating temperature & humidity 0 ~ 50 , under 85 %RH
Power Supply 100 ~ 220 VAC 50/60
Detection Power Range Standard : 0 ~ 100.0 /
Typical product : GUVA-S12SS2-3LWH3, GUVA-T11GS2-LW5.0, GUVC-T11GS2-LW10
MG-05 : GUVx-T1xGS5-xConstitution Monitor, Sensor Probe, Connection Cable
Description
Display Name Absolute Power Relative Power Accumulative Time
Unit / % Hours
Output Relay (COM, N/O/N/C)250VAC 3A/30VDC 3A
1-5V DC voltage 4-20 current300 Ω max load
Technology parameter
Operating temperature & humidity 0 ~ 50 , 35 ~ 85 %RH
Power Supply 85 ~ 265 V,AC 50/60
Detection Power Range 0 ~ 19,999 /
Typical product
Model No. Detection Range Application
GUVV-T10GC-LA2 230 ~ 395 UV Cure, UVA Lamp monitoring
GUVC-T11GS5-3LW5.0 220 ~ 280 Water Sterilization, UVC lamp monitoring
GUVC-T11GS5-3LW10 220 ~ 280 Water Sterilization, UVC lamp monitoring
MG-06 : GUVx-T1xGS6-xConstitution Monitor, Sensor Probe, Connection Cable
Description
Display Name Relative Power Accumulative Time
Unit % Hours
Output Relay (COM, N/O, N/C) : 250VAC 3A, 30VDC 3A
Technology parameter
Operating temperature & humidity 0 ~ 50 , 35 ~ 85 %RH
Power Supply 85 ~ 265 V,AC 50/60
Relative Power Range 0 ~ 100 %
Typical product
Model No. Detection Range Application
GUVC-T11GS6-3LW9.1 220 ~ 280 Water Sterilization, UVC lamp monitoring
GUVC-T11GS6-3LW10 220 ~ 280 Water Sterilization, UVC lamp monitoring