PI915.E 09.11 03_915_7333_ToniCALMör_PI_E.indd Application The mortarcalorimeter is a PC supported, isotherm diffe- rential calorimeter to measure continuously the heat of hy- dration, especially for flat mortar samples. The ToniCAL III measures online with the help of the software ToniDCA the generation of heat rate (J/g) in relation of the time of test. Measurements at other adhesive agents as cement and concrete up to 8mm gain size are possible. Advantages - rigid durable apparatus for industrial and laboratory use - high resolution and sensitivity - test of cement is possible without any limitation - test of concrete up to 8mm gain size is possible - simple handling - test procedure with extreme high information for pro- duct development - high reproducibility - recording and documentation and interpretation of the test results in numeric and graphic recording - self calibration system Design The ToniCAL III consists of a controller in a steel case and and the calorimeter unit with highly heat-isolated stainless steel cover. Into the controller the following features are integrated: - a triple step amplifier for the thermocouple signal - an electronic temperature controller for the heating of the calorimeter cell - a thermosignal indication for the inner cell temperature - the calibration unit Into the calorimeter unit the following components are integrated: - a measuring cell with the heating plates for placing the „dead“ sample and the test sample incl. all the necessary measuring points underneath the heating plates - one central and two radial working heating sources - the sample feeding unit for the „in situ“ mixing of the reactants in the thermo isolated sample test area - the measuring chain consists of multiple series con- nected thermosensors. The measuring chains bet- ween the „dead“ and the test sample are differentially connected. Working Principle A defined and weighted sample of cement/mortar has to be filled in the one way sample tray (dia. 90 mm). Then it shall be covered by a filter paper. The tray is placed on the heating plate inside the measu- ring cell. The tray is then closed by a cover with a guidance attachment for the water injection part. The measuring cell is closed by a fluid medium (regularly water) injection unit. The „dead“ sample part should consist of a similar material like the test sample and should be completely hydrated and/or reacted. After reaching the equilibri- um with the surrounding atmosphere the necessary fluid phase quantity will be added to the sample from outside. The test sample will be thouroughly penetrated and mixed with the fluid within seconds. The reaction heat is monitored as temperatu- re change from the very first moment onwards and recorded on the monitor. Parallel one can print the reaction curve and store the results. After finishing the reaction all data are available in a database for further comparison, storage and retrieving at any time. Mortarcalorimeter ToniCAL III Technik T oni Building Materials Testing Product Information Model 7333 Mortar Calorimeter ToniCAL III
2

Toni Technik Building Materials Testing...with cover, pack á 50 St. Injections 7333.004 50ml, pack á 10 St. Filter element 7333.005 Ø 85 mm Canula 7333.007 20Gx 1/2“ (0,9x40mm),

Aug 10, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Toni Technik Building Materials Testing...with cover, pack á 50 St. Injections 7333.004 50ml, pack á 10 St. Filter element 7333.005 Ø 85 mm Canula 7333.007 20Gx 1/2“ (0,9x40mm),

PI9

15.E

09.

11

03_915_7333_ToniCALMör_PI_E.indd

ApplicationThe mortarcalorimeter is a PC supported, isotherm diffe-rential calorimeter to measure continuously the heat of hy-dration, especially for flat mortar samples. The ToniCAL III measures online with the help of the software ToniDCA the generation of heat rate (J/g) in relation of the time of test. Measurements at other adhesive agents as cement and concrete up to 8mm gain size are possible.

Advantages- rigid durable apparatus for industrial and laboratory

use- high resolution and sensitivity- test of cement is possible without any limitation - test of concrete up to 8mm gain size is possible- simple handling- test procedure with extreme high information for pro-

duct development - high reproducibility- recording and documentation and interpretation of the

test results in numeric and graphic recording - self calibration system

DesignThe ToniCAL III consists of a controller in a steel case and and the calorimeter unit with highly heat-isolated stainless steel cover.

Into the controller the following features are integrated:

- a triple step amplifier for the thermocouple signal

- an electronic temperature controller for the heating of the calorimeter cell

- a thermosignal indication for the inner cell temperature

- the calibration unit

Into the calorimeter unit the following components are integrated:

- a measuring cell with the heating plates for placing the „dead“ sample and the test sample incl. all the necessary measuring points underneath the heating plates

- one central and two radial working heating sources

- the sample feeding unit for the „in situ“ mixing of the reactants in the thermo isolated sample test area

- the measuring chain consists of multiple series con-nected thermosensors. The measuring chains bet-ween the „dead“ and the test sample are differentially connected.

Working PrincipleA defined and weighted sample of cement/mortar has to be filled in the one way sample tray (dia. 90 mm). Then it shall be covered by a filter paper. The tray is placed on the heating plate inside the measu-ring cell. The tray is then closed by a cover with a guidance attachment for the water injection part. The measuring cell is closed by a fluid medium (regularly water) injection unit. The „dead“ sample part should consist of a similar material like the test sample and should be completely hydrated and/or reacted. After reaching the equilibri-um with the surrounding atmosphere the necessary fluid phase quantity will be added to the sample from outside. The test sample will be thouroughly penetrated and mixed with the fluid within seconds. The reaction heat is monitored as temperatu-re change from the very first moment onwards and recorded on the monitor. Parallel one can print the reaction curve and store the results. After finishing the reaction all data are available in a database for further comparison, storage and retrieving at any time.

Mortarcalorimeter ToniCAL III

TechnikToni Building Materials Testing

Product Information Model 7333Mortar Calorimeter ToniCAL III

Page 2: Toni Technik Building Materials Testing...with cover, pack á 50 St. Injections 7333.004 50ml, pack á 10 St. Filter element 7333.005 Ø 85 mm Canula 7333.007 20Gx 1/2“ (0,9x40mm),

All data at ambient temperature. Subject to technical modification.

Standard Delivery Includes:

Calorimeter 7333

Software 7333.001essential for the first measuring cell

Test container 7333.003with cover, pack á 50 St.

Injections 7333.00450ml, pack á 10 St.

Filter element 7333.005Ø 85 mm

Canula 7333.00720Gx 1/2“ (0,9x40mm), pack á 100 St.

Technical DataDimensions control unit (width x depth x height) calorimeter block (height x Ø)

mmmm

160 x 280 x 310750 x 440

Net weight conrtrol unit calorimeter block

kgkg

12,535

Temperature range °C +3 ... +55Initial weight solid liquid

gg

10 ... 1005 ... 50

Detection barrier µW/g 2,25Warm-up time h 8

For further information please contact:Toni Technik Baustoffprüfsysteme GmbHGustav-Meyer-Allee 2513355 BerlinTel: ++49 (0) 30/464039-21Fax: ++49 (0) 30/464039-22Email: [email protected]