Top Banner
Innovation is in our genes. 1 Siemens Medical Solutions Molecular Imaging TOMOGRAFIA POR EMISION DE POSITRONES PET Física y Aplicaciones II Congreso Nacional de Física Mario Rodriguez
30

TOMOGRAFIA POR EMISION DE POSITRONES PETpanamaspf.org/newspf/images/pdf/congreso2007/tomografia.pdf · 2016-02-04 · Innovation is in our genes. 3 Siemens Medical Solutions Molecular

Apr 25, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: TOMOGRAFIA POR EMISION DE POSITRONES PETpanamaspf.org/newspf/images/pdf/congreso2007/tomografia.pdf · 2016-02-04 · Innovation is in our genes. 3 Siemens Medical Solutions Molecular

Innovation is in our genes.

1 Siemens Medical Solutions Molecular Imaging

TOMOGRAFIA POR EMISION DE POSITRONES

PET

Física y Aplicaciones

II Congreso Nacional de Física

Mario Rodriguez

Page 2: TOMOGRAFIA POR EMISION DE POSITRONES PETpanamaspf.org/newspf/images/pdf/congreso2007/tomografia.pdf · 2016-02-04 · Innovation is in our genes. 3 Siemens Medical Solutions Molecular

Innovation is in our genes.

2 Siemens Medical Solutions Molecular Imaging

Imágenes Funcionales vsImágenes Anatómicas

PET, SPECT CT, Resonancia Magnética

Muestra la extensión de la enfermedad

Detecta cambios en la estructura y tamaño de un órgano

Útiles para monitorear tratamientos y evaluar su efectividad

Simplemente confirma la presencia de masas

Revela la enfermedad en etapas más tempranas

Puede diferenciar si una masa es benigna o maligna

Detecta anormalidades ntes que ocurra un cambio en la anatomía

Page 3: TOMOGRAFIA POR EMISION DE POSITRONES PETpanamaspf.org/newspf/images/pdf/congreso2007/tomografia.pdf · 2016-02-04 · Innovation is in our genes. 3 Siemens Medical Solutions Molecular

Innovation is in our genes.

3 Siemens Medical Solutions Molecular Imaging

Un poquito de historia

En 1975 se fabricó el primer equipo de PET comercial

Hasta 1990 su uso fue casi exclusivamente en sitios de investigación

En 1990 se estableció el uso del PET como herramienta clínica, con aplicaciones en Oncología

Page 4: TOMOGRAFIA POR EMISION DE POSITRONES PETpanamaspf.org/newspf/images/pdf/congreso2007/tomografia.pdf · 2016-02-04 · Innovation is in our genes. 3 Siemens Medical Solutions Molecular

Innovation is in our genes.

4 Siemens Medical Solutions Molecular Imaging

El principio básico de PET

1. Trazador emisor de positrones es inyectado en el cuerpo

2. Positrones emitidos (β+) viajan 1 – 3 mm

3. Positrones chocan con electrones (β-) causando una “anilacion”

4. La anilacion emite energia en forma de dos fotones de 511 keV volando a ~180 grados el uno del otro

5. Los fotones son detectados por detectores de centelleo opuestos

6. Se usa la discriminacion de energia para asegurarse que cada foton es de ~511 keV

7. La discriminacion temporal se utiliza para asegurarse que los fotones provienen de la misma anilacion. De esta forma se garantiza la exactitud en la localizacion del trazador

1

2

3

4

4

5

5

6

6

7

Page 5: TOMOGRAFIA POR EMISION DE POSITRONES PETpanamaspf.org/newspf/images/pdf/congreso2007/tomografia.pdf · 2016-02-04 · Innovation is in our genes. 3 Siemens Medical Solutions Molecular

Innovation is in our genes.

5 Siemens Medical Solutions Molecular Imaging

Detección en COINCIDENCIA

Page 6: TOMOGRAFIA POR EMISION DE POSITRONES PETpanamaspf.org/newspf/images/pdf/congreso2007/tomografia.pdf · 2016-02-04 · Innovation is in our genes. 3 Siemens Medical Solutions Molecular

Innovation is in our genes.

6 Siemens Medical Solutions Molecular Imaging

Eventos Verdaderos

∆E energy window

∆E energy window

Eventos VerdaderosActividad Inyectada∝

� Una anilacion

� Energía de los fotones dentro de la

ventana de discriminacion de energía

� Detección de los fotones dentro de la

ventana de coincidencia

Page 7: TOMOGRAFIA POR EMISION DE POSITRONES PETpanamaspf.org/newspf/images/pdf/congreso2007/tomografia.pdf · 2016-02-04 · Innovation is in our genes. 3 Siemens Medical Solutions Molecular

Innovation is in our genes.

7 Siemens Medical Solutions Molecular Imaging

Eventos Accidentales

� Dos anilaciones� Energía de los fotones dentro de

la ventana de discriminacion de energía

� Detección de los fotones dentro de la ventana de coincidencia

Eventos AccidentalesActividad Inyectada 2∝

Page 8: TOMOGRAFIA POR EMISION DE POSITRONES PETpanamaspf.org/newspf/images/pdf/congreso2007/tomografia.pdf · 2016-02-04 · Innovation is in our genes. 3 Siemens Medical Solutions Molecular

Innovation is in our genes.

8 Siemens Medical Solutions Molecular Imaging

Reducción de Eventos Accidentales

Parametro relevante:

� Ventana de coincidencia

Ventana de coincidencia

Even

tos a

ccid

en

tale

s

12 ns

6 ns

4.5 ns

Page 9: TOMOGRAFIA POR EMISION DE POSITRONES PETpanamaspf.org/newspf/images/pdf/congreso2007/tomografia.pdf · 2016-02-04 · Innovation is in our genes. 3 Siemens Medical Solutions Molecular

Innovation is in our genes.

9 Siemens Medical Solutions Molecular Imaging

Eventos Dispersados

� Una anilación

� Detección dentro de la ventana de coincidencia

� Pérdida de energía debido a la dispersión

� Sin embargo la eneriía aún esta dentro de la ventana de energía

La fracción de fotones dispersados depende del objeto

Page 10: TOMOGRAFIA POR EMISION DE POSITRONES PETpanamaspf.org/newspf/images/pdf/congreso2007/tomografia.pdf · 2016-02-04 · Innovation is in our genes. 3 Siemens Medical Solutions Molecular

Innovation is in our genes.

10 Siemens Medical Solutions Molecular Imaging

Espectro de energía para eventos detectados en PET y reducción de la fracción de dispersión

Los eventos en PET están distribuidos a través de un rango de energía, es decir, no todos los eventos tienen exactamente 511 keV. La fraccion de dispersion se reduce con la ventana de energía.

350 – 650

Ventana de energía

425 – 650

Co

nte

o

Energía (keV)

0 100 200 300 400 700600500

Fotones dispersados

Fotones de 511 keV

BGO

LSO

Page 11: TOMOGRAFIA POR EMISION DE POSITRONES PETpanamaspf.org/newspf/images/pdf/congreso2007/tomografia.pdf · 2016-02-04 · Innovation is in our genes. 3 Siemens Medical Solutions Molecular

Innovation is in our genes.

11 Siemens Medical Solutions Molecular Imaging

Reconstrucción de la Imagen

Page 12: TOMOGRAFIA POR EMISION DE POSITRONES PETpanamaspf.org/newspf/images/pdf/congreso2007/tomografia.pdf · 2016-02-04 · Innovation is in our genes. 3 Siemens Medical Solutions Molecular

Innovation is in our genes.

12 Siemens Medical Solutions Molecular Imaging

Detectores utilizados en PET

Page 13: TOMOGRAFIA POR EMISION DE POSITRONES PETpanamaspf.org/newspf/images/pdf/congreso2007/tomografia.pdf · 2016-02-04 · Innovation is in our genes. 3 Siemens Medical Solutions Molecular

Innovation is in our genes.

13 Siemens Medical Solutions Molecular Imaging

Emisores de Positrones

Núcleo rico en

protones

ν++→ +− eYXA

Z

A

Z 1

Page 14: TOMOGRAFIA POR EMISION DE POSITRONES PETpanamaspf.org/newspf/images/pdf/congreso2007/tomografia.pdf · 2016-02-04 · Innovation is in our genes. 3 Siemens Medical Solutions Molecular

Innovation is in our genes.

14 Siemens Medical Solutions Molecular Imaging

Radioisótopo Vida Media (min)

11C 21

13N 10

15O 2

18F 110

Emisores de Positrones

Page 15: TOMOGRAFIA POR EMISION DE POSITRONES PETpanamaspf.org/newspf/images/pdf/congreso2007/tomografia.pdf · 2016-02-04 · Innovation is in our genes. 3 Siemens Medical Solutions Molecular

Innovation is in our genes.

15 Siemens Medical Solutions Molecular Imaging

Radiofarmacia en PET

Page 16: TOMOGRAFIA POR EMISION DE POSITRONES PETpanamaspf.org/newspf/images/pdf/congreso2007/tomografia.pdf · 2016-02-04 · Innovation is in our genes. 3 Siemens Medical Solutions Molecular

Innovation is in our genes.

16 Siemens Medical Solutions Molecular Imaging

Cómo se produce el FDG?

Page 17: TOMOGRAFIA POR EMISION DE POSITRONES PETpanamaspf.org/newspf/images/pdf/congreso2007/tomografia.pdf · 2016-02-04 · Innovation is in our genes. 3 Siemens Medical Solutions Molecular

Innovation is in our genes.

17 Siemens Medical Solutions Molecular Imaging

Que se puede detectar con PET?

Page 18: TOMOGRAFIA POR EMISION DE POSITRONES PETpanamaspf.org/newspf/images/pdf/congreso2007/tomografia.pdf · 2016-02-04 · Innovation is in our genes. 3 Siemens Medical Solutions Molecular

Innovation is in our genes.

18 Siemens Medical Solutions Molecular Imaging

Enfermedades en las arterias coronarias

PET tiene la capacidad única de diferenciar si el músculo

cardíaco de un paciente se puede beneficiar de una cirugía de

la arteria coronaria para implante de un bypass

Page 19: TOMOGRAFIA POR EMISION DE POSITRONES PETpanamaspf.org/newspf/images/pdf/congreso2007/tomografia.pdf · 2016-02-04 · Innovation is in our genes. 3 Siemens Medical Solutions Molecular

Innovation is in our genes.

19 Siemens Medical Solutions Molecular Imaging

Enfermedades en las arterias coronarias

Las flechas muestran tejido muerto: no hay beneficio con un bypass

Corazón normal

Page 20: TOMOGRAFIA POR EMISION DE POSITRONES PETpanamaspf.org/newspf/images/pdf/congreso2007/tomografia.pdf · 2016-02-04 · Innovation is in our genes. 3 Siemens Medical Solutions Molecular

Innovation is in our genes.

20 Siemens Medical Solutions Molecular Imaging

Tumores

PET tiene mucha precisión diferenciando entre tumores benignos y malignos, así como también mostrando el grado de extensión anatómica de los tumores malignos. PET ayuda a detectar tumores de cerebro recurrentes, tumores de pulmón, colon, mamas, nodos linfáticos piel y otros órganos. Información obtenida del PET puede ser usada para determinar qué tipo de tratamiento o combinación de tratamientos es más adecuado para tratar exitosamente un tumor

Page 21: TOMOGRAFIA POR EMISION DE POSITRONES PETpanamaspf.org/newspf/images/pdf/congreso2007/tomografia.pdf · 2016-02-04 · Innovation is in our genes. 3 Siemens Medical Solutions Molecular

Innovation is in our genes.

21 Siemens Medical Solutions Molecular Imaging

Tumores (Cáncer de mamas)

Cáncer de mamas que no fue detectado con las técnicas convencionales de imágenes (CT, Resonancia, mamografía)

Otra vista de la misma paciente. A través de una biopsia se encontró que los nódulos linfáticos estaban en metástasis

Page 22: TOMOGRAFIA POR EMISION DE POSITRONES PETpanamaspf.org/newspf/images/pdf/congreso2007/tomografia.pdf · 2016-02-04 · Innovation is in our genes. 3 Siemens Medical Solutions Molecular

Innovation is in our genes.

22 Siemens Medical Solutions Molecular Imaging

Cerebro

PET puede proveer información para evaluar disfunciones del cerebro. PET puede mostrar la región del cerebro que causa los ataques cerebrales. Además es útil evaluando enfermedades degenerativas del cerebro como Alzheimer, Huntington y Parkinson.

Page 23: TOMOGRAFIA POR EMISION DE POSITRONES PETpanamaspf.org/newspf/images/pdf/congreso2007/tomografia.pdf · 2016-02-04 · Innovation is in our genes. 3 Siemens Medical Solutions Molecular

Innovation is in our genes.

23 Siemens Medical Solutions Molecular Imaging

Cerebro

Cerebro normalCerebro de una niña de 9 años con una historia de ataques de epilepsia muy frecuentes. La flecha muestra el área responsable de los ataques. Una intervención quirúrgica paró los ataques

Page 24: TOMOGRAFIA POR EMISION DE POSITRONES PETpanamaspf.org/newspf/images/pdf/congreso2007/tomografia.pdf · 2016-02-04 · Innovation is in our genes. 3 Siemens Medical Solutions Molecular

Innovation is in our genes.

24 Siemens Medical Solutions Molecular Imaging

PET-CT

Necesidad de tener ambas juntas: imágenes anatómicas e imágenes funcionales

Estudio con FDG: Pulmón o Vertebras?

Estudio con 124I: Hueso o tejido suave?

Page 25: TOMOGRAFIA POR EMISION DE POSITRONES PETpanamaspf.org/newspf/images/pdf/congreso2007/tomografia.pdf · 2016-02-04 · Innovation is in our genes. 3 Siemens Medical Solutions Molecular

Innovation is in our genes.

25 Siemens Medical Solutions Molecular Imaging

Solución vía software o hardware

-Movimiento interno de los órganos

-Inconveniente para el paciente ya que son dos estudios separados los que hay que realizar

-El alineamiento del paciente debe ser sumamente preciso, lo cual es muy difícil lograr

-Resuelve todas las dificultades anteriores

-Las imágenes están listas inmediatamente

-Pero, la corrección para la atenuación de los fotones del estudio de PET es el reto principal para los Físicos Médicos

Page 26: TOMOGRAFIA POR EMISION DE POSITRONES PETpanamaspf.org/newspf/images/pdf/congreso2007/tomografia.pdf · 2016-02-04 · Innovation is in our genes. 3 Siemens Medical Solutions Molecular

Innovation is in our genes.

26 Siemens Medical Solutions Molecular Imaging

Primer prototipo PET-CT

David Townsend, Físico Médico de la Universidad de Pittsburg presentó en 1998 el primer prototipo hibrido PET-CT. Esto lo logró con SIEMENS

Page 27: TOMOGRAFIA POR EMISION DE POSITRONES PETpanamaspf.org/newspf/images/pdf/congreso2007/tomografia.pdf · 2016-02-04 · Innovation is in our genes. 3 Siemens Medical Solutions Molecular

Innovation is in our genes.

27 Siemens Medical Solutions Molecular Imaging

Corrección de atenuación vía CT

Page 28: TOMOGRAFIA POR EMISION DE POSITRONES PETpanamaspf.org/newspf/images/pdf/congreso2007/tomografia.pdf · 2016-02-04 · Innovation is in our genes. 3 Siemens Medical Solutions Molecular

Innovation is in our genes.

28 Siemens Medical Solutions Molecular Imaging

Del prototipo al BIOGRAPH

Page 29: TOMOGRAFIA POR EMISION DE POSITRONES PETpanamaspf.org/newspf/images/pdf/congreso2007/tomografia.pdf · 2016-02-04 · Innovation is in our genes. 3 Siemens Medical Solutions Molecular

Innovation is in our genes.

29 Siemens Medical Solutions Molecular Imaging

PET-CT en Radioterapia

Page 30: TOMOGRAFIA POR EMISION DE POSITRONES PETpanamaspf.org/newspf/images/pdf/congreso2007/tomografia.pdf · 2016-02-04 · Innovation is in our genes. 3 Siemens Medical Solutions Molecular

Innovation is in our genes.

30 Siemens Medical Solutions Molecular Imaging

PET-CT en Radioterapia