NT 361 Eco / NT 361 Eco TE

NT 561 Eco / NT 561 Eco TE

www.kaercher.com 5.959 - 693 A2009775 12/04

Page 2: TLE TLE.CDR:CorelDRAW

NT 361 Eco / NT 361 Eco TE / NT 561 Eco / NT 561 Eco TE 2

SAFETY INSTRUCTIONS 3Commissioning 6Operating Instructions 7Accessories / Filter Systems 26/27Technical Data / Wiring diagram / Spare Parts List 28/29/30This machine is suitable for industrial use, for instance in hotels, schools, hospitals, factories,shops, offices and on hire. CONSIGNES DE SÉCURITÉ 10Mise en service 14Notice d'instructions / Système de filtres 15Accessoires 26/27Caractéristiques techniques / Schéma de câblage / Liste des pièces de rechange 28/29/30Cet appareil est adapté à l'usage professionnel, p. ex. dans les hôtels,les écoles, les hôpitaux, les usines, les magasins, les bureaux et les locations. INSTRUCCIONES DE SEGURIDAD 18Puesta en servicio 22Instrucciones de servicio 23Accesorios / Sistemas del Filtro 26/27Datos técnicos / Diagrama de conexiones / Lista de piezas de requesto 28/29/30Este aparato es apropiado para el uso a escala industrial, p. ej. en hoteles, centros escolares,hospitales, fábricas, tiendas comerciales, oficinas y empresas dedicadas al alquiler.

Page 3: TLE TLE.CDR:CorelDRAW

English NT 361 Eco / NT 361 Eco TE / NT 561 Eco / NT 561 Eco TE 3

IMPORTANTSAFETYINSTRUCT-IONS

READ ALLINSTRUCT-IONSBEFOREUSING THISMACHINE.

• Inform your dealer immediately ifthere is any transport damage.

• Completely remove theaccessories from the carton.

• The suction unit is not siuitable forsucking up hazardous dusts asasbestos. Please consult yourKärcher branch or your Kärcherdealer with regard to suchapplications.

• Only operate the suction unit froma suitable socket outlet withearthing contact. Refer to theTechnical data for the necessarymains fuse.

• Connect to a properly groundedoutlet only - see Groundinginsructions.

When using an electrical appliance,basic precautions should always befollowed, including the following:This vacuum is intended forcommercial use.

1. DISCONNECT VACUUMCLEANER FROM POWERCIRCUIT before removing thecover, performing maintenancework, and when not in use.

2. DO NOT LEAVE appliancewhen pugged in.

3. ALWAYS CHECK THEPOWER SUPPLY CORD fordamage or signs of any agingbefore each use.

4. DO NOT PULL OR CARRYVACUUM CLEANER BYCORD. Do not close door andcord or pull cord around sharpedges.

5. KEEP CORD AWAY FROMHEAT AND OIL. Do not leavecord lying around after job iscomplete. It can become atripping hazard.

6. DO NOT RUN VACCUMOVER CORD.

7. TURN SWITCH TO OFFbefore unplugging powersupply cord.

8. DO NOT UNPLG BY PULLINGCORD. To unplug, grasp plug,not cord.

9. DO NOT GRASP PLUG WITHWET HANDS.

10. A DAMAGED CORD OR PLUGshould only be replaced by anauthorized service centerrepresentative. DO NOTATTEMPT TO REPAIRPOWER CORD.

11. TO AVOID SHOCK, do notexpose to rain. Store indoors.

12. USE ONLY ASRECOMMENDED BY THISMANUAL. Use only withrecommended attachments.

13. KEEP HAIR, CLOTHING,LOOSE JEWELRY, FINGERSand all parts of the body awayfrom openings and movingparts.

14. DO NOT BLOCK OROBSTRUCT OPENINGS. Keepopenings free of lint, hair, dust,and anything that restricts airflow.

15. DO NOT PICK UP ANYTHINGTHAT IS BURNING,smoldering, or smoking suchas matches, cigarettes, or hotashes.

16. DO NOT USE TO VACUUMCOMBUSTIBLE EXPLOSIVEMATERIALS, such as coal,grain, and other finely dividedcombustible material.

Page 4: TLE TLE.CDR:CorelDRAW

English NT 361 Eco / NT 361 Eco TE / NT 561 Eco / NT 561 Eco TE 417. DO NOT USE TO VACUUM

COMBUSTIBLE, hazardous,toxic, or carcinogenic materials,including gasoline, diesel fuel,acetone, paint thinner, heatingoils, undiluted acids andsolvents, pesticide, andasbestos.

18. USE RECOMMENDEDFILTERS when vacuumingdrywall materials.

19. DO NOT USE WHITOUTFILTER and/or dust bag inproper place.

20. CONNECT VACUUMCLEANER WHITH PROPERLYGROUNDED OUTLET ONLY.See grounding instructions.

21. DO NOT ALLOW VACUUMCLEANER TO BE USED AS ATOY. Keep children away fromVacuum Cleaner.

22. DO NOT LEAVEUNATTENDED while VacuumCleaner is running.

23. DO NOT USE IF CORD,PLUG, FILTER, OR VACUUM150

24. CLEANER IS IN POORCONDITION. If the VacuumCleaner has been dropped,damaged, exposed to weather,or dropped into water; have it

checked byan authorized service .

25. ALWAYS USE EYEPROTECTION when operatingVacuum Cleaner.

26. USE EXTRA CAUTION whenoperating on stairs.

27. STAY ALERT! Do not useVacuum Cleaner when you aretired or under the influence ofdrugs, alcohol or medication.

SAVE THESEINSTRUCT-IONS

This vacuumis intendedforcommercialuse.

SAFETYINSTRUC-TIONS

GROUNDINGINSTRUCT-IONSThis appliance must be grounded. Ifit should malfunction or breakedown,grounding provides a path of leastresistance for electric current toreduce the risk of electric shock.This appliance is equipped with acord having an equipmentgroundingconductor and ground plug.The plug must be inserted into anappropriate outlet that is properlyinstalled and grounded inaccordance with all local codes andordinances.

WARNING:Improper connection of theequipment-grounding conductor canresult in a risk of electric shock.

Check with a qualified electrican orservice person if you are in doubt asto whether the outlet is properlygrounded.Do not modify the plug providedwhith the appliance.If it will not fit the outlet, have aproper outlet installed by a qualifiedelectrican.This appliance is for use on anominal 120-volt circuit, and has agrounded plug that looks like theplug illustrated in Fig.A.A temporary adapter that looks likethe adapter illustrated in Fig.B, maybe used to connect this plug to atwo-pole receptacle as shown inFig.B, if a properly grounded outletis not available.The temporary adapter should beused only until a properly groundedoutlet (Fig.A) is installed by aqualified electrican.The green colored rigid ear, lug, orthe like extending from the adaptermust be connected to a permanentground such as a properly groundedoutlet box cover.Whenever the adapter is used, itmust be held in place by a metalsrew.

WARNING:In Canada, the use of a temporaryadapter is not permitted by theCanadian Electrical Code.

Page 5: TLE TLE.CDR:CorelDRAW

English NT 361 Eco / NT 361 Eco TE / NT 561 Eco / NT 561 Eco TE 5

IN ALLCASES,MAKE SURETHERECEPT-ACLE INQUESTION ISPROPERLYGROUNDED.

NEVERREMOVEGROUNDINGPRONGFROM

POWERPLUG.

EXTENSIONCORDSUse only three-wire extensionscords that have three-ponggrounding-type plugs and three-polereceptacle that accepts theappliance's plug. Replace damagedor worn cord immediately.

DO NOTATTEMPTTO REPAIRPOWERCORD.

Figure A

1. Groundet outlet box2. Current carrying prongs

Grounding prong is longest of the3 prongs

Figure B

1. Groundet outlet box2. Grounding means3. Adapter

SERVICINGOF DOUBLE-INSULATEDAPPLIANCESIn a double-insulated appliance, twosystems of insulation are providedinstead of grounding. No groundingmeans is provided on a double-insulated appliance, nor should ameans for grounding be added tothe appliance. Servicing a double-insulated appliance requiresextreme care and knowledge of thesystem, and should be done only byqualified service personnel.Replacement parts for a double-insulated appliance must beidentical to the parts they replace.

Page 6: TLE TLE.CDR:CorelDRAW

NT 361 Eco / NT 361 Eco TE / NT 561 Eco / NT 561 Eco TE 6

Page 7: TLE TLE.CDR:CorelDRAW

English NT 361 Eco / NT 361 Eco TE / NT 561 Eco / NT 561 Eco TE 7OPERATING INSTRUCTIONS

Manual modeDry suction

♦ The surface filter is never to beremoved during suction.

♦ A paper filter bag or a membranefilter can also be used whensucking up fine dust.

Fitting the paper filter bag¾ Unlock and remove the suction

head¾ Insert the paper filter bag¾ Replace the suction head and lock

it in place

Fitting the membrane filter¾ Unlock and remove the suction

head¾ Pull the membrane filter over the

container edge¾ Replace the suction head and lock

it in place

Note:The paper filter bag is not required

Fitting the brush strip

Insert power plugSwitch on the machine and startusing it.

Power Filter Clean / FilterdedustingThe surface filter is cleanedautomatically by interrupting the airflow (approx. 10-15 s.)

♦ Actuate the remote control forPower Filter Clean at the handle atregular intervals, during drysuctioning as well as uponfinishing work.

Page 8: TLE TLE.CDR:CorelDRAW

English NT 361 Eco / NT 361 Eco TE / NT 561 Eco / NT 561 Eco TE 8Manual modeWet suction

♦ The surface filter is never to beremoved during suction.

♦ The paper filter bag andmembrane filter must be removedwhenever wet dirt is sucked up.

♦ The machine is not switched offwhen the container is full with non-conductive liquids (e.g. drillingemulsion, oils und greases

♦ The filling level must be checkedconstantly and the container mustbe emptied in good time.

Fitting rubber lips

Note:The structured side of the rubber lipsmust show outwards.

¾ Remove the paper filter bag¾ Remove the membrane filter¾ Insert power plug¾ Switch on the machine and start

using it

Note:♦ Power Filter Clean is activated

automatically (hammering noise)when sucking up water from a fullcontainer.

♦ Clean and dry the surface filter,electrodes, and container whenfinished wet-vacuuming.

Automatic operation(only NT 561/361 Eco TE)

¾ Plug in the electric tool mains plugon the suction machine.(3)

¾ Switch on the machine (1)¾ The standby lamp is lit (2)

Note:♦ The vacuum cleaner is

automatically switched on and offwith the electric tool.

♦ The vacuum cleaner has a startingdelay of approx. 0,5 s and an afterrunning time of max. 15 s.

♦ Electric tools of 100-2200 Wcan be connected.

Match the junction box to the electrictool connector.

♦ Remove the pipe bend from thesuction hose

♦ Fit the junction box to the suctionhose

Page 9: TLE TLE.CDR:CorelDRAW

English NT 361 Eco / NT 361 Eco TE / NT 561 Eco / NT 561 Eco TE 9

Connect the junction box to theelectric tool

CARE AND MAINTENANCE

♦ Always pull out the mains plugwhen working on the suctionmachine.

Cleaning/changing the surfacefilter

¾ Open the filter cover (1) and takeout the surface filter (2).

¾ Cleaning / changing the surfacefilter

¾ Close the filter cover, it must lockaudibly

Changing the output air filter

Open the filter cover (1) andexchange the exhaust air filter (2).

Clean electrodes

¾ Unlock and remove the suctionhead

¾ Clean electrodes¾ Replace the suction head and lock

it in place

FAULT INSTRUCTIONS

The suction turbine does not run• Check the cable, plug, fuse and

socket.• Switch on the machine.

The suction turbine switches off• Empty the container.

Suction force diminishes• Remove clogging material from

the suction nozzle, suction pipe,Power Filter Clean, suction hose,or surface filter.

• Activate the remote control forPower Filter Clean on the handle.

• Change the paper filter bag.• Lock the filter cover in place.• Cleaning/changing the surface

filter.

Dust ejects when sucking• Check the surface filter is

positioned correctly.• Change the surface filter.

Automatic switch-off (wetsuction) is defective• Clean electrodes.• Constantly check the filling level

for an electrical non-conductiveliquid.

Power Filter Clean switchesregularly• Loosen suction nozzle or end of

hose when caught on vacuumedobject.

• End continuous suction from theliquid container.

• Remove clogging material fromthe suction nozzle, suction pipe,Power Filter Clean, suction hose,or surface filter.

• Change the surface filter.

Page 10: TLE TLE.CDR:CorelDRAW
Page 11: TLE TLE.CDR:CorelDRAW

Filtersysteme / Filter Systems / Système de filtres 27

Norm alstäubeNorm al dustPoussières norm ales

Fe instäubeFine dustPoussières fines

Abrasive S täubeAbrasive dustPoussières abrasives

Flüssigkeiten / nasser SchmutzLiquids / wet dirtLiquides / saletès hum ides

Flachfa ltenfilte r (B IA C gep rüft)F lat pleated filte r (B IA C app roved)F iltre p la t à p lis (C on trôle B IA C )

F lachfa ltenfilte r (B IA C gep rüft)F lat pleated filte r (B IA C app roved)F iltre p la t à p lis (C on trôle B IA C )

F lachfa ltenfilte r (B IA C gep rüft)F lat pleated filte r (B IA C app roved)F iltre p la t à p lis (C on trôle B IA C )

F iltertü te 2 -lag ig (B IA C gepüft)P aper filte r bag double laye red (B IA C approved )S ache t filtre à 2 épaisseurs (C on trôlé B IA C )

F iltertü te 2 -lag ig (B IA C gepüft)P aper filte r bag double laye red (B IA C approved )S ache t filtre à 2 épaisseurs (C on trôlé B IA C )

M em bra nfilte rD iaph ragm filterF iltre à m em bra ne

Flachfa ltenfilte r (B IA C gep rüft)F lat pleated filte r (B IA C app roved)F iltre p la t à p lis (C on trôle B IA C )

M em bra nfilte rD iaph ragm filterF iltre à m em bra ne

M em bra nfilte rD iaph ragm filterF iltre à m em bra ne

S pezia lfiltertü teS pecia l filte r bagS ache t filtre spécial

S pezia lfiltertü teS pecia l filte r bagS ache t filtre spécial

1

2

3

4

B estell-N r. / O rde r No . / Num éro de ré fé rence

N T 361 E co / TE N T 561 / NT 611 E co/TE

6.904-206

6.904-208

6.904-212

6.904-206

6.904-212

6.904-206

6.904-208

6.904-212

6.904-211

6.904-190

6.904-211

6.904-210

6.904-210

6.904-171

6.904-171

6.904-206

6.904-212

6.904-206

6.904-212

6.904-206

6.904-212

6.904-190

Page 12: TLE TLE.CDR:CorelDRAW

NT 361 Eco / NT 361 Eco TE / NT 561 Eco / NT 561 Eco TE 28

120 V/1~60 Hz

7,5 m

SJTW-A 2/16AWG(NT 361 / 561 Eco) 6.648 - 370

SJTW-A 3/14AWG(NT 361 / 561 Eco TE) 6.648 - 311

63 db (A)

I nom: 9 A

NT 361 Eco / NT 361 Eco TE34 l

NT 561 Eco / NT 561 Eco TE45 l

NT 361 Eco / NT 361 Eco TE20 l

NT 561 Eco / NT 561 Eco TE31 l

max. 54 l/s

max. 23,5 kPa

NT 361 Eco / NT 361 Eco TE505 mm x 370 mm x 535 mm

NT 561 Eco / NT 561 Eco TE505 mm x 370 mm x 640 mm

NT 361 Eco / NT 361 Eco TE1.184.xxx: 9,5 kg

NT 561 Eco / NT 561 Eco TE1.145.xxx: 11 kg

35 mm

NT 361 / 561 Eco

II

NT 361 / 561 Eco TE

I: 1-6 A

Page 13: TLE TLE.CDR:CorelDRAW

NT 361 Eco / NT 361 Eco TE / NT 561 Eco / NT 561 Eco TE 29

B1 ElektrodenElectrodesElectrodes

C1 EntstörkondensatorSuppression Capacitor

Condensateur AntiparasitesH1 Signalleuchte

Pilot LampLampe Tenoin

M1 SaugturbineSuction Turbine

Turbine d’aspirationN1 Platine

Circuit BoardPlatine

S1 Schalter TurbineSwitch Suction TurbineInterrupteur de Turbine

S2 Umschalter BetriebsartSwitch

InverseurX1 Stecker

PlugFiche

X2, X5 SteckkupplungPlug-In Coupling

Raccord PriseX6 Steckdose

SocketPrise de Courant

* Nur für Variante TE Only for version TE Unique ment pour variation TE

120V 1~ 50/60Hz

M 1

X1

L1

L2

PE *

S1

X6* S2*

H1*

13 12 11 10 1 2 3 4

9 78 6 5

*

X4*24V_ 24V_X3

N1

C1X2X5*

B142

1

viol

et

whi

te /

neu t

ral

v io l

e t

wh

ite /

neu t

ral

w h ite / neu tra l

b lack

p rote ctive conduc to r

w h ite / neu tra l P hase vio le t

w h ite / neu tra l P hase / b lack

g reen (ye llow )

Page 14: TLE TLE.CDR:CorelDRAW

NT 361 Eco / NT 361 Eco TE / NT 561 Eco / NT 561 Eco TE 30

Page 15: TLE TLE.CDR:CorelDRAW

NT 361 Eco / NT 361 Eco TE / NT 561 Eco / NT 561 Eco TE 31

6.904-191.0

NT 561 ECO

6.435-197.0

5.031-601.0

5.031-601.0

6.904-215.0

6.435-370.0

6.435-370.0

4.060-420.0

6.900-514.0

5.031-703.0

6.435-196.0

6.343-168.0

5.031-604.0

4.321-122.0

7.303-154.0

7.303-154.0

7.303-154.0

5.031-603.0

5.044-224.0

6.906-240.0

25.09.2000

6.648-370.0

1.145-105.0 * CUL

6.903-284.0

6.903-277.06.903-278.0

5.031-718.0

6.363-078.0

6.906-208.0

5.031-703.0

6.906-208.0

2.639-690.0

6.904-206.0

6.904-191.0

NT 561 ECO TE

6.435-197.0

5.031-601.0

5.031-601.0

6.904-215.0

6.435-370.0

6.435-370.0

4.060-420.0

6.900-514.0

5.031-703.0

6.435-196.0

6.343-168.0

5.031-604.0

4.321-122.0

7.303-154.0

7.303-154.0

7.303-154.0

5.031-603.0

5.044-224.0

6.906-240.0

25.09.2000

6.903-284.0

6.903-277.06.903-278.0

6.648-311.0

1.145-205.0 * CUL

5.031-718.0

5.453-042.0

6.363-078.0

6.906-208.0

5.031-703.0

6.906-208.0

2.639-690.0

6.904-206.0