Typhoon propane vapour gas burning heaters are of stainless steel and chrome construction with a sturdy steel box section mounting frame designed to give many years of trouble free service. Each heater is adjustable and can be raised or lowered to direct the heat into the fan inlet to suit single or multiple fan applications. The control panel is detachable and can be mounted either side of the unit or in other positions in the fan house. The controls give a digital readout of humidity or temperature depending on the purpose it is being used for, grain drying, onion drying or frost protection. TKG 260/8 TKG 390/12 1200,000 "QUALITY IN STORE" TKG MODULATING GAS HEATERS PELLCROFT ENGINEERING LTD., COLDHAM ROAD, CONINGSBY, LINCOLN LN4 4SA TEL: (01526) 342466 FAX: (01526) 343507
2
Embed
TKG MODULATING GAS HEATERS - PELLCROFT · TKG 130/4 TKG 250/7 TKG 260/8 TKG 390/12 400,000 700,000 800,000 1200,000 BTUs BTUs BTUs BTUs "QUALITY IN STORE" TKG MODULATING GAS HEATERS
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Typhoon propane vapour gas burning heaters are of stainless steel and chrome
construction with a sturdy steel box section mounting frame designed to give
many years of trouble free service.
Each heater is adjustable and can
be raised or lowered to direct the
heat into the fan inlet to suit single
or multiple fan applications. The
control panel is detachable and
can be mounted either side of the
unit or in other positions in the fan
house.
The controls give a digital readout
of humidity or temperature
depending on the purpose it is
being used for, grain drying, onion
drying or frost protection.
TKG 130/4
TKG 250/7
TKG 260/8
TKG 390/12
400,000
700,000
800,000
1200,000
BTUs
BTUs
BTUs
BTUs
"QUALITY IN STORE"
TKG MODULATING GAS HEATERS
PELLCROFT ENGINEERING LTD.,COLDHAM ROAD, CONINGSBY, LINCOLN LN4 4SA
TEL: (01526) 342466 FAX: (01526) 343507
Wheat
Barley
Oats
Rape
Peas
Ryegrass
Beans
MODULATING HEATER
When using the TKG burner to dry grain the fan should be run continuously until
the grain is at 18% moisture content, 12% for Rape, from then on run the fan with
the burner switched on.
Set TKG relative humidity setting to obtain a 2% lower than the actual material
moisture content. I.E. Barley moisture content 18% set to 16% = 75% R.H. (See
chart below).
Check material moisture content regularly. Reduce R.H. setting to keep a 2%
lower than actual moisture content.
When desired grain/material moisture content is attained, operate FAN ONLY
with TKG in off position until grain is cooled.
In this way the minimum use of heat is required and the maximum use of