Thunder Palladium Store 1000

User’s Guide

Pinnacle® Systems, Inc.280 N. Bernardo AvenueMountain View, CA 94043

June 2004

P/N 327000112REV. B

Page 2: Thunder Palladium Store 1000 - Avidresources.avid.com/SupportFiles/attach/PS1000_users_guide... · 8 Thunder Palladium Store 1000 User’s Guide • Set is the host block size: Press

2

Trademarks

All brand or product names mentioned herein are used for identification purposes only and may be trademarks or registered trademarks of their respective companies.

Copyright © 2004 Pinnacle Systems, Inc.All Rights Reserved.

Reproduction, adaptation, or translation of this document without prior written permission is prohibited, except as allowed under copyright laws.

Printed in the United States.

Note: The information in this document is subject to change without notice or obligation.

Important: If available, you can obtain later versions of this and other related manuals in Adobe Acrobat PDF format on the Web at www.pinnaclesys.com/support.

Page 3: Thunder Palladium Store 1000 - Avidresources.avid.com/SupportFiles/attach/PS1000_users_guide... · 8 Thunder Palladium Store 1000 User’s Guide • Set is the host block size: Press

Official Notices and Warranties

Software License Agreement IMPORTANT—READ CAREFULLY: This Software License Agreement is a legal agreement between You and Pinnacle (or its suppliers). This System contains certain Pinnacle computer software (“Software”), associated media, printed materials, and electronic documentation. By using the Software, You agree to be bound by the terms of this Software License Agreement. If You do not agree to the terms of this Software License Agreement, Pinnacle is unwilling to license the Software to You. In such case, You may not use or copy the Software. This system also contains certain third party software, which is provided to You upon the condition that You agree to the terms outlined in the third party software licenses included with the materials shipped with the System.

License: Pinnacle grants to You a nonexclusive, personal, perpetual, nontransferable, limited license to use the installed Software exclusively on hardware on which Pinnacle has loaded the Software, or other hardware on which Pinnacle has authorized it to be loaded, but solely in connection with the operation of Your internal business, and not for the benefit of any third party. Such Software may only be enabled by Pinnacle or its authorized agent. Pinnacle and its licensors retain all right, title and interest in and to all Software, but title to the media on which the Software is delivered is transferred to You.

Restrictions: The Software is copyrighted and may contain material that is protected by patent, trade secret or other laws pertaining to proprietary rights. You may not copy the Soft-ware, except that it may make a single copy for archival purposes. You may not modify the Software or permit or assist any third party in doing so. You may not decompile, reverse engi-neer, disassemble, or otherwise reduce the Software to source code or other human-readable form, or attempt or permit any third party to do so. Any violation of this Software license shall be a material breach and shall immediately entitle Pinnacle to exercise any remedy that may exist at law or in equity.

Copyright: All title and copyrights in the Software (and any copies thereof) and the accom-panying printed materials are owned by Pinnacle. All rights not specifically granted under this Software License Agreement are reserved by Pinnacle.

Limited Warranty: Pinnacle warrants that (a) the Software will perform substantially in accordance with the published specifications for a period of one year from the date of receipt and (b) any Pinnacle hardware will be free from defects in materials and workmanship under normal use and service for a period of one year from the date of receipt.

This warranty will not apply to repair or replacement necessitated by accident, disaster, improper or inadequate maintenance, customer or customer-supplied interfacing or machines, unauthorized modifications or repairs, improper electrical current, misuse, abuse or improper installation. This warranty is personal to You and may not be assigned or transferred. Pinna-cle does not warrant that the Software will operate error-free.

THE LIMITED WARRANTY SET FORTH HEREIN IS THE ONLY WARRANTY, EXPRESS, IMPLIED OR STATUTORY THAT PINNACLE MAKES WITH RESPECT TO

Page 4: Thunder Palladium Store 1000 - Avidresources.avid.com/SupportFiles/attach/PS1000_users_guide... · 8 Thunder Palladium Store 1000 User’s Guide • Set is the host block size: Press

4 Thunder Palladium Store 1000 User’s Guide

THE PRODUCTS. ALL IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PAR-TICULAR PURPOSE AND NONINFRINGEMENT, ARE DISCLAIMED.

Limitation of Liability PINNACLE SHALL NOT BE LIABLE FOR INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES; FOR DAMAGES THAT DIRECTLY OR INDIRECTLY ARISE FROM YOUR USE OF, OR INABILITY TO USE, THE SYSTEM; FOR COMMERCIAL LOSS OF ANY KIND; FOR THE PROCUREMENT OF SUBSTITUTE GOODS--WHETHER ARISING IN TORT, CONTRACT OR ANY OTHER LEGAL THEORY, EVEN IF PINNACLE HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN ANY EVENT, PINNACLE’S LIABILITY SHALL BE LIMITED TO THE AMOUNT ACTUALLY PAID BY YOU FOR THE SYSTEM GIVING RISE TO ANY SUCH DAMAGE. THIS LIMITATION IS INTENDED TO LIMIT PINNACLE’S LIABILITY AND SHALL APPLY NOTWITHSTANDING ANY FAILURE OF ESSENTIAL PURPOSE OF ANY LIMITED REMEDY.

Page 5: Thunder Palladium Store 1000 - Avidresources.avid.com/SupportFiles/attach/PS1000_users_guide... · 8 Thunder Palladium Store 1000 User’s Guide • Set is the host block size: Press

Table of Contents

CHAPTER 1: INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Configuring the PS1000 for Thunder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Verify Firmware Version 128 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Configuring the SR 12 Storage Array . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

CHAPTER 2: RAID STORAGE ARRAY ADMINISTRATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Rebuilding Failed Disks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Formatting an Array . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Creating a File System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Adding Arrays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

CHAPTER 3: RAID HARDWARE REMOVAL AND REPLACEMENT . . . . . . . . . . . . . . . . . . . . . . 13Control Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13Hot Swappable Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Replacing a RAID Disk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Replacing the Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Replacing the Fan Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Replacing the Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Replacing a Bridge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Adding Disk Sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

Page 6: Thunder Palladium Store 1000 - Avidresources.avid.com/SupportFiles/attach/PS1000_users_guide... · 8 Thunder Palladium Store 1000 User’s Guide • Set is the host block size: Press

Contents

2 Thunder Palladium Store 1000 Use’s Guide

Page 7: Thunder Palladium Store 1000 - Avidresources.avid.com/SupportFiles/attach/PS1000_users_guide... · 8 Thunder Palladium Store 1000 User’s Guide • Set is the host block size: Press

Chapter 1: Installation

Configuring the PS1000 for ThunderImportant: Before beginning this procedure, remove any Fibre Channel cables connected to the Palladium Store 1000 storage array.

Figure 1-1 shows the front panel of the Palladium Store 1000. When facing the front panel, the Control Panel is on your left.

Figure 1-1: Palladium Store 1000 Front Panel

Figure 1-2 shows a diagram of the rear panel of the Palladium Store 1000. Note the location of the Fibre Channel cable connection.

Figure 1-2: PS1000 Rear Panel

DCAC

DCAC

Power Supply 1

Power Supply 2

Status

Service

Switc

h C

onto

ller

Switc

h C

onto

ller

Port4

Port2

Port1

Port3

AB

Fibre Channel Connection

Page 8: Thunder Palladium Store 1000 - Avidresources.avid.com/SupportFiles/attach/PS1000_users_guide... · 8 Thunder Palladium Store 1000 User’s Guide • Set is the host block size: Press

Chapter 1: Installation

4 Thunder Palladium Store 1000 User’s Guide

Follow these steps to configure the Palladium Store 1000:

1. With the Fibre Channel cable disconnected, power on the Palladium Store 1000.

2. Verify that all LEDs on the Control Panel are green. Be sure that the LED for the fan is green. Figure 1-3 shows a diagram of the Control Panel.

Figure 1-3: Control Panel

3. In the Control Panel, the Controller A LED should display a series of three-digit numbers, such as 002, 102. The third digit in each three-digit sequence indicates the address, which is 2. Verify that the address (ALPA value) is 2 on the display.

4. To change the ALPA number, use the navigation buttons (see Figure 1-3). Pressing the right arrow causes a cursor on the LED indicator to appear. Press the right arrow again to move the cursor to the third number, for example, 002. To increase the ALPA value, press the up arrow. To decrease the value, press the down arrow. Set the ALPA value to 2. Press and hold the center button (Alarm Silence/Enter button) for 15 seconds. The other values should change to this new ALPA.

Note: If the front panel beeps, press the Alarm Silence/Enter button to silence it.

5. Attach the fibre channel cable to the Fibre Channel connector on the Palladium Store 1000. See Figure 1-2.

6. Power on the Thunder computer.

silence

enter

ChA address

ChB address

TemperatureDrive Status

Fans Status

Power Supplies

Controller Status

Controller A LEDIndicator

Not UsedAlarm SilenceEnter Button

PanelNavigation Buttons

ALPA Value

Page 9: Thunder Palladium Store 1000 - Avidresources.avid.com/SupportFiles/attach/PS1000_users_guide... · 8 Thunder Palladium Store 1000 User’s Guide • Set is the host block size: Press

Chapter 1: Installation

Thunder Palladium Store 1000 User’s Guide 5

Verify Firmware Version 128The firmware version for the PS1000 should be 128. To verify the firmware version:

1. Open a command-line window on the Thunder computer. (Go to Start > Run. Type cmd in the text box).

2. Change directories to the PS1000 directory by entering:

cd c:\ps1000

3. To display version information, enter:

scsi_set_mode –i

4. In the output, verify that Medea SR12 FC X128 is displayed for PhysicalDrive1.

128 is the firmware version.

5. If the firmware version is not 128, contact Pinnacle Technical Support for assistance.

6. Remove the CD, power cycle the array, and restart the Thunder computer.

Configuring the SR 12 Storage ArrayFollow these procedures to configure the SR 12 storage array:

1. Establish the connection to the array.

To establish a connection to the SR 12 array, you will need a serial cable (DB-9, female connectors) and a PC running HyperTerminal, or any other terminal program that can emulate VT100. (These instructions assume that you have HyperTerminal.) Connect the cable to the COM1 port of your PC and to the service port of the Controller to be configured.

Start HyperTerminal (go to Start > Programs > Accessories > Communications >HyperTerminal).

Verify

Page 10: Thunder Palladium Store 1000 - Avidresources.avid.com/SupportFiles/attach/PS1000_users_guide... · 8 Thunder Palladium Store 1000 User’s Guide • Set is the host block size: Press

Chapter 1: Installation

6 Thunder Palladium Store 1000 User’s Guide

Choose a name for your connection and start it with the following settings:

• Connect using: COM 1

• Bits per second: 57600

• Data bits: 8

• Parity bits: none

• Stop bits: 1

• Flow control: none

From the File menu of the HyperTerminal window, select Properties. In the Properties dialog box, select the Settings tab. In this tab (see Figure 1-4), select Terminal keys and Ctrl-H. Select VT100 as the terminal emulator from Emulation menu). After making these selections, click OK.

Figure 1-4: HyperTerminal Setup

You should now be connected to the array. If your connection is not established, check the physical link first, then the settings, and try again. If you still cannot connect, reboot your PC and power cycle the array. If this attempt is unsuccessful, try to establish the connection using another cable.

Page 11: Thunder Palladium Store 1000 - Avidresources.avid.com/SupportFiles/attach/PS1000_users_guide... · 8 Thunder Palladium Store 1000 User’s Guide • Set is the host block size: Press

Chapter 1: Installation

Thunder Palladium Store 1000 User’s Guide 7

2. Perform the configuration process.

If the connection has been established, you should now see the start screen of the SR 12 command-line interface:

• Press any key to enter the main menu, which resembles the following:

• Press 1 to enter the configuration dialogue.

Page 12: Thunder Palladium Store 1000 - Avidresources.avid.com/SupportFiles/attach/PS1000_users_guide... · 8 Thunder Palladium Store 1000 User’s Guide • Set is the host block size: Press

Chapter 1: Installation

8 Thunder Palladium Store 1000 User’s Guide

• Set is the host block size: Press 2 to set this parameter to 2048 Bytes.

• When prompted to choose the array’s stripe size, press 4 to select 2097152 (2 MB).

• Enter the Fibre Channel Loop ID. The value depends on the number of arrays already connected. Press 2.

The next option enabled or disables the Controller.

• Press 1 to enable the Controller.

Page 13: Thunder Palladium Store 1000 - Avidresources.avid.com/SupportFiles/attach/PS1000_users_guide... · 8 Thunder Palladium Store 1000 User’s Guide • Set is the host block size: Press

Chapter 1: Installation

Thunder Palladium Store 1000 User’s Guide 9

The next option asks you to select single- or multi-Controller mode.

• Select 1 for single Controller.

You are now asked to enter a value for the array’s IDE read timeout.

• Type 400 and press Enter.

Do the same at the next prompt, which sets the IDE write timeout.

You are requested to set the gross timeout.

• Enter 1400 and press Enter.

• When asked to set the check condition, press 1 (first non-redundant state).

• Select 0 for AV mode ERP read Recovery.

• Select option 1 (Send Check Condition at First Persistent Non-redundant).

Page 14: Thunder Palladium Store 1000 - Avidresources.avid.com/SupportFiles/attach/PS1000_users_guide... · 8 Thunder Palladium Store 1000 User’s Guide • Set is the host block size: Press

Chapter 1: Installation

10 Thunder Palladium Store 1000 User’s Guide

• A screen shows the configurations you have made. You are prompted whether or not to continue with the configuration. Press Y to proceed.

• At the main menu select option 3 (Reconstruct Menu).

• Select option 7 (Set Reconstruct DMA Timeout Values).

• Enter 550 as the timeout and press Enter.

• Press any key to continue, then close the HyperTerminal window.

• Reboot both the array and the Thunder computer.

Page 15: Thunder Palladium Store 1000 - Avidresources.avid.com/SupportFiles/attach/PS1000_users_guide... · 8 Thunder Palladium Store 1000 User’s Guide • Set is the host block size: Press

Chapter 2: RAID Storage Array Administration

This chapter discusses how to administer the Palladium Store 1000 RAID storage arrays.

Each RAID consists a chassis with a RAID Bridge and 10 disks, which come in two disk sets. A disk set consists of five disks (four standards disks and one redundant disk). Figure 2-1 shows the Palladium Store 1000.

Figure 2-1: PS1000 Drive Bay

The RAID Controller hardware manages the disk controller functions, which include:

• Formatting the array

• Reading and writing data

• Checking data parity

• Rebuilding disks

Important: If two or more disks in a set fail (a set consists of 4 storage disks plus 1 parity disk), all of the data in the storage array will be lost.

Palladium Store 1000 Drive Bay with Cover Removed

Bay 1 (A)Drives 1 - 5 Drives 6 - 10

Bridge A Bay 2 (B)

Page 16: Thunder Palladium Store 1000 - Avidresources.avid.com/SupportFiles/attach/PS1000_users_guide... · 8 Thunder Palladium Store 1000 User’s Guide • Set is the host block size: Press

Chapter 2: RAID Storage Array Administration

12 Thunder Palladium Store 1000 User’s Guide

Rebuilding Failed DisksAny time you replace a disk, you must rebuild the array. A rebuild calculates the lost data from the parity disk and remaining data disks and adds it to the new disk. For information on replacing drives see “Replacing a RAID Disk” on page 15.

If a disk has failed:

1. Remove the failed disk – You can determine the failed disk number by running the array_services array0<x> command. The disks are numbered 1-10, from left to right.

2. Replace with a new disk. The rebuild begins automatically when the new drive is inserted.

Warning: Do not attempt firmware updates on any system that has a failed drive in one or more RAID storage arrays. No software or firmware upgrades should be performed on any malfunctioning system.

Formatting an ArrayBecause the array is formatted at the factory, no reformatting is required. Should the disk ever need reformatting, contact Pinnacle Technical Support for assistance.

Creating a File SystemThe formatted array contains its own file system. Creating a new file system destroys all content. If you need to create a new file system, contact Pinnacle Technical Support for assistance.

Adding ArraysA Thunder can support more than one RAID chassis. RAID chassis can be added in volume sets. The initial disk set will determine how additional storage can be added to your system. For information about adding RAID storage array enclosures, consult Pinnacle Technical Support.

Page 17: Thunder Palladium Store 1000 - Avidresources.avid.com/SupportFiles/attach/PS1000_users_guide... · 8 Thunder Palladium Store 1000 User’s Guide • Set is the host block size: Press

Chapter 3: RAID Hardware Removal and Replacement

The Palladium Store 1000 is housed in a RAID chassis. It consists of field-replaceable modules that can be hot swapped.

Control PanelThe Palladium Store 1000 Control Panel is attached to the RAID front cover (see Figure 3-1). You must remove the indicator panel to access the drives.

Figure 3-1: RAID Control Panel

The indicator panel displays the following:

• Controller address display

• Temperature status - light turns red to indicate a cooling failure

• Drive status – indicates drive activity and drive failure

• Fan status – turns red in the event of a fan failure

• Controller status – turns red in the event of a Controller failure

silence

enter

ChA address

ChB address

TemperatureDrive Status

Fans Status

Power Supplies

Controller Status

Controller A LEDIndicator

Not UsedAlarm SilenceEnter Button

PanelNavigation Buttons

ALPA Value

Page 18: Thunder Palladium Store 1000 - Avidresources.avid.com/SupportFiles/attach/PS1000_users_guide... · 8 Thunder Palladium Store 1000 User’s Guide • Set is the host block size: Press

Chapter 3: RAID Hardware Removal and Replacement

14 Thunder Palladium Store 1000 User’s Guide

Use the navigation buttons to set addresses for the Controller. Use the center button to enter values and to silence the alarm.

Hot Swappable ComponentsThe following components can be replaced while the unit is operational:

• Power supplies (dual redundant supplies)

• RAID drives

• Fans

Warning: There are two fans in a fan module. Failure of one of them will trigger an alarm and the Fan indicator light.The unit can run safely with one fan in operation. Do not remove the fan module on an operating unit without having a replacement fan ready for installation. Running the Palladium Store 1000 unit without a cooling module for more than a few minutes could result in damage to the unit, and will result in shutdown if temperature thresholds are exceeded.

Figure 3-2: Palladium Store 1000: Top and Front Views

You access the RAID disks and the Bridge from the front of the RAID unit. Remove the front panel to access the Bridge and drives. Figure 3-2 shows the location of the replaceable RAID

Bay 1 (A)Drives 1-5

Bay 2 (B)Drives 6-10

Bridge

DriveBay

Fan

Controller

PowerSupplies

Top View

Front View

Page 19: Thunder Palladium Store 1000 - Avidresources.avid.com/SupportFiles/attach/PS1000_users_guide... · 8 Thunder Palladium Store 1000 User’s Guide • Set is the host block size: Press

Chapter 3: Introducing PALLADIUM Exchange

Thunder Palladium Store 1000 User’s Guide 15

disks and the Bridge. The front of a RAID disk is labeled Drive number A 1-5 (bank A), or B 1-5 (bank B). The Bridge is labeled C.

Figure 3-3 shows the Palladium Store 1000’s rear panel, which provides access to the hot-swapped units: the dual redundant power supplies and a fan module that consists of two fans.

Figure 3-3: Palladium Store 1000 Rear Panel

Replacing a RAID DiskA failed disk drive is indicated by a red LED on the drive in the unit. Replace failed drives as soon as possible to avoid loss of content.

As shown in Figure 3-2, drives are numbered A1 to A 5 in the left bank (bank A) and B6 to B10 in the right bank (bank B).

Warning: Make sure you remove the failed drive from the chassis. Removing the wrong drive results in loss of content.

To replace a RAID storage array disk:

1. Remove the front panel cover to access the disk drive bay (see Figure 3-2).

2. Press your forefinger into the indentation at the lower part of the disk (see Figure 3-4). The disk pops out slightly.

3. Gently grasp the cover flap and pull the disk out a few inches. Wait 30 seconds for the drive to spin down. Then completely remove the drive from the drive bay.

4. Affix the correct drive label on the replacement drive (labels are shipped with the unit).

5. Carefully slide the replacement drive into the drive bay. Open the front flap to guide the disk to the rear of the drive bay until it snaps into rear connection.

6. Press the cover flap down until it clicks in place, locking the drive.

7. Check the drive indicator to see if the new drive is in place. Drive reconstruction begins automatically (see “Rebuilding Failed Disks” on page 12).

DCAC

DCAC

Power Supply 1

Power Supply 2

Status

Service

Sw

itch

Con

tolle

r

Sw

itch

Con

tolle

r

Port4

Port2

Port1

Port3

AB

FanControllerPower Supplies

Page 20: Thunder Palladium Store 1000 - Avidresources.avid.com/SupportFiles/attach/PS1000_users_guide... · 8 Thunder Palladium Store 1000 User’s Guide • Set is the host block size: Press

Chapter 3: RAID Hardware Removal and Replacement

16 Thunder Palladium Store 1000 User’s Guide

Figure 3-4: Replacing a Disk

Figure 3-5: RAID Disk

Step 1 Step 2

Page 21: Thunder Palladium Store 1000 - Avidresources.avid.com/SupportFiles/attach/PS1000_users_guide... · 8 Thunder Palladium Store 1000 User’s Guide • Set is the host block size: Press

Chapter 3: Introducing PALLADIUM Exchange

Thunder Palladium Store 1000 User’s Guide 17

Replacing the Power SupplyFigure 3-6 shows the Palladium Store 1000 power supply. A failed power supply triggers an audible alarm. The LED indicator on the failed unit turns red, which signifies a component failure.

To replace a power supply:

1. Note the failed power supply’s position and check the LED indicator to make sure you are removing the correct power supply. Remove the power connector from the failed unit.

2. Facing the rear of the unit, loosen the two retaining screws (see Figure 3-6).

3. Firmly pull on the retaining handle and carefully slide the unit out of the chassis, making sure to clear any cables in the way.

4. Reverse the process to insert the replacement unit.

Note: Pressing the center button on one of the RAID Controller panels turns off the alarm.

Figure 3-6: Palladium Store 1000 Power Supply

DCAC

Pull Handle

2 Screws to Remove

Page 22: Thunder Palladium Store 1000 - Avidresources.avid.com/SupportFiles/attach/PS1000_users_guide... · 8 Thunder Palladium Store 1000 User’s Guide • Set is the host block size: Press

Chapter 3: RAID Hardware Removal and Replacement

18 Thunder Palladium Store 1000 User’s Guide

Replacing the Fan ModuleThe fan module is housed in the fan slot at the rear of the Palladium Store 1000. A failed fan triggers an audible alarm, indicating a component failure. The fan module consists of two fans, so air should be circulating unless both fans have failed.

Warning: If you do not have a replacement fan, do not remove the module. Operating the unit for more than a few minutes without a cooling unit could result in damage to the unit and cause the unit to shutdown if temperature thresholds are exceeded.

To replace the fan:

1. Grasp the side of the fan unit with your thumb on the top. See Step A in Figure 3-8.

2. Pull the fan unit slightly downward, and then pull it towards you to remove it (Step B in Figure 3-8).

3. Position the new fan as shown in Step B. Insert it into the slot (Step A) until the fan unit snaps into place.

Figure 3-7: Fan Unit and Fan Slot

Figure 3-8: Removing the Fan

Step A Step B

Page 23: Thunder Palladium Store 1000 - Avidresources.avid.com/SupportFiles/attach/PS1000_users_guide... · 8 Thunder Palladium Store 1000 User’s Guide • Set is the host block size: Press

Chapter 3: Introducing PALLADIUM Exchange

Thunder Palladium Store 1000 User’s Guide 19

Replacing the ControllerThe failure of the RAID Controller is indicated by LEDs on the front panel and the Bridge’s display indicator. The Controller is mounted with the drives in the front of the RAID chassis (left of center) and is labeled with a C on the latch handle.

Important: If a Controller fails, its associated Bridge (mounted in the back of the unit) must also be replaced.

To replace the Controller:

1. Remove the front panel cover to access the disk drive bay (see Figure 3-2).

2. Press your forefinger into the indentation at the lower part of the Bridge (see Figure 3-9). The disk pops out slightly.

3. Gently grasp the cover flap and pull the Bridge completely out of the drive bay.

4. Carefully slide the replacement Bridge into the drive bay. Open the front flap to guide the disk to the rear of the drive bay until it snaps into the rear connection.

5. Press the cover flap down until it clicks in place, locking the drive.

Figure 3-9: Removing a Controller

Replacing a BridgeTo remove the Bridge:

1. Loosen the two large retaining screws (on either side of the handle).

2. Remove the cables plugged into the board (note their location).

3. Carefully pull the handle out towards you, being careful to clear any cables.

4. Reverse this procedure when inserting a new Bridge.

Page 24: Thunder Palladium Store 1000 - Avidresources.avid.com/SupportFiles/attach/PS1000_users_guide... · 8 Thunder Palladium Store 1000 User’s Guide • Set is the host block size: Press

Chapter 3: RAID Hardware Removal and Replacement

20 Thunder Palladium Store 1000 User’s Guide

Figure 3-10: Bridge Removal

Adding Disk SetsAdditional storage may be added to your unit. For more information on adding storage capacity to your system, consult with your Pinnacle Customer Sales Representative.

Retaining Screw

Retaining Screw

v