The Tru-Fit ™ Series from CNI Replacement Chassis Packaged Terminal Air Conditioners/Heat Pumps Dimensional and Engineering Data Specifications Tru-Fit Replacement for Singer/McQuay Series S,RS, EA Tru-Fit Replacement for Nesbitt ® Modular Roommate Tru-Fit Replacement for Nesbitt ® Roommate PKG Tru-Fit Replacement for AAF ® Series 16 Comitale National, Inc. 1683 B Winchester Road • Bensalem, PA 19020 • 215- 244-9650 • FAX 215-244-9679 Visit our website - www.comitalenational.com • email: [email protected]
20
Embed
TheTru-Fit Series from CNI Replacement Chassis Packaged ... · Integral Style - A complete, self-contained chassis consisting of motor assembly, heating and cooling system, along
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
TheTru-Fit™Series from CNIReplacement ChassisPackaged TerminalAir Conditioners/Heat PumpsDimensional and Engineering Data Specifications
Tru-Fit Replacement for Singer/McQuay Series S,RS, EA
All CNI refrigeration tubing is specially designed to eliminate noise transmission throughsheet metal. The competition does not, allowing higher noise level.
2.All CNI water holding pans are fully protected with a mastic coating which repels water.
The competition does not, which shortens the life of the product from corrosion.
3.All wires in the CNI control box are fully insulated. This ensures of an unsurpassed amount of
safety against electrical shorting. The competition uses exposed electrical terminals.
4.All CNI sheet metal is of l8 gauge galvanized zinc plated steel. The base pan is 16 gauge
galvanized. The competition uses lighter gauge steel to save money.
5.All CNI chassis are provided with a low limiting thermostat. This gives the product an addedsafety against freeze ups on the evaporator coil due to low ambient or a clogged filter.
The competition does not provide this feature.
6.All CNI chassis use Sporlan thermostatic expansion valves. This allows the evaporator coil to
be full under all load conditions. The competition uses a cheaper automatic expansion valve.This starves the evaporator at high load conditions and overfeeds it at low load conditions.
7.All CNI chassis use what is known as Blow-Through design, which sends air through the coil.
The competition uses a draw through method, which causes recirculation ofcondenser hot air and results in unit premature failure. This method also causes the unit
to draw higher amperage which costs more money to operate and maintain.Also when using the propeller condenser fan method - ice will lock up the
condenser fan preventing operation of the unit in the winter.
As you can see from the above list, CNI chassis provide you with standardfeatures that the competition considers specials or are unable to provide.
Our products are far superior in construction and quality.
CNI reserves the right to make changes in design and construction at any time without notice.
Comitale National Inc.3
Comitale National, Inc.Family owned and operated for three generations.
The sample unit nomenclature above indicates a CNI Cooling Chassis for replacement of a McQuay Type "K"; 9000 BTUH, 208-230/60/1, Hydronic Heat, Unit Mounted, Manual Changeover, No Control Options, Standard
Design and Rotary Compressor.
NEMA 6-15R (250V)
Service: 15 Amp Voltage: 208/230V
NEMA 5-15R (115V)
Service: 15 Amp Voltage: 115V
Comitale National Inc.5
Mating Power Receptacles for CNI Integral Style Units
NEMA 7-20R (277V)
Service: 20 Amp Voltage: 277V
NEMA 6-20R (250V)
Service: 20 Amp Voltage: 208/230V
NEMA 6-30R (250V)
Service: 30 Amp Voltage: 208/230V
Integral Style - A complete, self-contained chassis consisting of motor assembly, heating andcooling system, along with a control box.
W
NEMA 5-20R (115V)
Service: 20 Amp Voltage: 115V
139-0100 139-0011
139-0101 139-0018
139-0010 139-0012
NE M A R E C E P T A C L E S
Comitale National Inc.6
TYPE CCCO SERIESReplacement Packaged Terminal Air Conditioners
TYPE CAF16O SERIESReplacement Packaged Terminal Air Conditioners
Replaces Original Nesbitt® andMSI® Challenger Cooling andHeatpump Chassis.
Replaces Original American AirFilter® Type 16, WY, YY, andENERSAVER, Singer® andMcQuay® Type ENH, ENR,PNES1, PNHS1 Cooling andHeatpump Chassis.
14
35 3/4
5
4 1/2 x 23
DISCHARGE AREA
CONTROL BOX 20 1/2
15 1/2
10 1/2
DISCHARGE AREA
34 1/2
5
14 7/8
19
14 1/2
S E C T I O N 1Integral Style - A complete, self-contained chassis consisting of motor assembly, heating andcooling system, along with a control box.
Select NEMA cord from page 5.
Select NEMA cord from page 5.
TYPE CTPIO SERIESReplacement Packaged Terminal Air Conditioners
Replaces Original T.P.I.®, Cool Heat® Type RM, ClimateMaster® 702, 703,and 704 Type,Embassy Weather Twin®, Ice Cap® RSK Type, Kapsis®, Ra-Matic®, Beacon Morris® andZoneAire® Corp. RM and SCType Cooling and HeatpumpChassis.
18 8
43/4 DISCHARGE AREA
CONTROL BOX
36
281
15
Select NEMA cord from page 5.
Comitale National Inc.7
TYPE CFOO SERIESReplacement Packaged Terminal Air Conditioners
Replaces Original Fedders®Unizone, Climatrol®, Climazone®
UVK, UVW, UVY and Airtemp®
Tempzone Cooling andHeatpump Chassis.
18 1/2 47
DISCHARGE AREA
15 3/8 14 1/2
28 1/4 5 1/2 CONTROL BOX
TYPE CA45O SERIESReplacement Packaged Terminal Air Conditioners
Replaces Original AmericanStandard®, Singer® Type SG45and 45, Carteret® Type 45,McQuay® Type PNES2 andPNHS2 Cooling and HeatpumpChassis.
DISCHARGE AREA
34 1/2
5
14 7/8
19
14 1/2
S E C T I O N 1
Select NEMA cord from page 5.
Select NEMA cord from page 5.
TYPE CRSO SERIESReplacement Packaged Terminal Air Conditioners
Replaces Original Singer® andMcQuay® Type S, ES, RS, MQTPMES and PMRS Cooling andHeatpump Chassis.Note advise factory:Coil Placement - High or LowExtendaire or Ducted Application.
43 7/8
CONTROL BOX
15 14 x 42 5/8
18 1/2
81/2 10
Select NEMA cord from page 5.
Comitale National Inc.8
TYPE CEAFO SERIESReplacement Packaged Terminal Air Conditioners
Replaces Original Singer® andMcQuay® Type EA-F, MEA, MQAand PMES Cooling and HeatpumpChassis.Note advise factory:
Extendaire or Ducted Application.
43 7/8
CONTROL BOX
1514 x 42 5/8
18 1/2
81/2 10
TYPE CSEAO/CSHAO SERIESReplacement Packaged Terminal Air Conditioners
Replaces Original Heil Quaker®Type SEA and SHA Cooling andHeatpump Chassis.
18 8
43/4 DISCHARGE AREA
CONTROL BOX
36
281
15
S E C T I O N 1
Select NEMA cord from page 5.
Select NEMA cord from page 5.
Select NEMA cord from page 5.
TYPE CEALO SERIES Replacement Packaged Terminal Air Conditioners
Replaces Original Singer® andMcQuay® Type EA-A/L.H., MEA,MQA and PMES Cooling andHeatpump Chassis.Note advise factory:
Extendaire or Ducted Application.
45 44
DISCHARGE AREA 4 x 21 17
15 1/2 15 X 44
17
81/2
Comitale National Inc.9
S E C T I O N 1
TYPE CWRBO SERIESReplacement Packaged Terminal Air Conditioners
Replaces Original Westinghouse®
and Coastal Products® Type RBCooling and Heatpump Chassis.
DISCHARGE AREACONTROL BOX
3 7/8 x 29
71/2381/4
151/4
201/8
141/2
Select NEMA cord from page 5.
TYPE CEARO SERIESReplacement Packaged Terminal Air Conditioners
Replaces Original Singer® andMcQuay® EA - A/R.H., MEA,MQA and PMES Cooling andHeatpump Chassis.Note advise factory:
Extendaire or Ducted Application.
FUSE BOX
AUX. ELEC. BOX
44 1/4
43 3/8
DISCHARGE AREA
5 x 24
15 1/815 7/8
19 3/8
17 1/2
8 3/4
14 5/8
Select NEMA cord from page 5.
Call CNI for more details and competitive pricing!
Ask about our Quick Shipment Program.
Think CNI for all of your replacement HVAC parts needs.
A lower cost alternative to all seasoncomfort conditioning....More Reliability ...Less Maintenance...Simpler Installation ...Higher Efficiency...A Quieter Solution ...A Tru-FitQuality and Comfort for manyyears to come!
Look to CNI for all of your Water Source Heat Pump needs, replacement,
retrofit, or for new construction. Consult factory for additional information.
180F DB/67F WB air entering evaporator; 95F DB/75F WB air entering condenser per ARI Std. 310-70. 2 200F EWT/180F LWT at 2 GPM 70F EAT. 3 2 PSI 70F EAT saturated steam.CNI reserves the right to modify specifications without prior notice in its efforts to improve product quality.
D A T A S H E E TS E C T I O N 1 INTEGRAL STYLE
Wattage, Amperage & EER is based on compressor and condensing fan motor data.
Comitale National Inc.11
TYPE CMRO SERIESReplacement Packaged Terminal Air Conditioners
TYPE CRPO SERIESReplacement Packaged Terminal Air Conditioners
Replaces Original Nesbitt® andMSI® Modular RoommateCooling and Heatpump Chassis.
Note advise factory:Front panel slope or flat.Wall sleeve high or low intake.
Replaces Original Nesbitt® andMSI® Roommate PKG Coolingand Heatpump Chassis.
34
18 17
19
14
Component Style - Consisting of separate; cooling chassis, heating section, evaporative motor-board assembly and control box.
DISCHARGE AREA
30
34
MODEL - 07, 09,12
MODEL - 15,18 11
14 1/2
17 1/2
S E C T I O N 2
Call CNI for more details and competitive pricing!
Ask about our Quick Shipment Program.
Think CNI for all of your replacement HVAC parts needs.
A lower cost alternative to all seasoncomfort conditioning....More Reliability ...Less Maintenance...Simpler Installation ...Higher Efficiency...A Quieter Solution ...A Tru-FitQuality and Comfort for manyyears to come!
Look to CNI for all of your Water Source Heat Pump needs, replacement,
retrofit, or for new construction. Consult factory for additional information.
Comitale National Inc.12
TYPE CNIIIO SERIESReplacement Packaged Terminal Air Conditioners
Replaces Original DunhamBush® Newport, III, IV, and VCooling and Heatpump Chassis.
41 1/2
5 1/2 x 19 1/2
13 5/8
11/2
13 1/21
31/2
TYPE CAF25O SERIESReplacement Packaged Terminal Air Conditioners
Replaces Original American AirFilter®, McQuay® Type 25, GXYand XY, Nelsonaire® Type 25Cooling and Heatpump Chassis.
36
34 1 17 3/8
17 14
14 5/8 18 5/8
14 1/4
17 3/8
3 1/8
4 3/8
TYPE CA41O SERIESReplacement Packaged Terminal Air Conditioners
Replaces Original AmericanStandard® Series 41, McQuay®
and Remotaire® Cooling andHeatpump Chassis.
12 5/8
17
14 1/4 X 34
17 1/4
35 5/8
S E C T I O N 2
Comitale National Inc.13
S E C T I O N 2TYPE CRJO SERIES
Replacement Packaged Terminal Air Conditioners
Replaces Original Remington®,Singer® and McQuay® Type J-EJ,EJB, JB, EJC, JC, MQC, MEJ,PMEJ, PMEH Cooling andHeatpump Chassis.
28 3/8”
25 5/8”
20 3/64”
9 1/2”
12 27/32”
TYPE CRKO SERIESReplacement Packaged Terminal Air Conditioners
Replaces Original Remington®/Singer® and McQuay® Type K,EK, RK, MEK, MHK, MQP, PKESand PKHS Cooling andHeatpump Chassis.
CFM-COOLING AND HEATINGHigh Speed 340 340 340 435 435Low Speed 290 290 290 375 375Ventilation 70 70 70 85 85Indoor Motor HP 1/20 1/20 1/20 1/20 1/20Outdoor Motor HP 1/4 1/4 1/4 1/4 1/4
Fan Motor Data
Recommended Overcurrent Protection - Amperes
Recommended Overcurrent Protection - Amperes
Heating - Reverse Cycle Heat Pump Only
Hydronic Heat
Cooling - Heat Pump and Cooling Only Chassis
180F DB/67F WB air entering evaporator; 95F DB/75F WB air entering condenser per ARI Std. 310-70. 2 200F EWT/180F LWT at 2 GPM 70F EAT. 3 2 PSI 70F EAT saturated steam.CNI reserves the right to modify specifications without prior notice in its efforts to improve product quality.* Wattage, Amperage & EER is based on compressor and condensing fan motor data.
S E C T I O N 2 - COMPONENT STYLE D A T A S H E E T
Additional Manufactured Parts forTru-Fit™ Replacement Chassis
MOTOR BOARD ASSEMBLIES
CONTROL BOXES
PLENUM ASSEMBLIES
HYDRONIC COILS &VALVE ASSEMBLIES
ELECTRIC ELEMENT ASSEMBLIES
Consists of:• Evaporator Motorboard• Control Box
• Heating SectionHot Water, Steam or Electric
Note: Complete Room Cabinet Assemblies, Wall Sleeves, Outdoor Louvers, Room Cabinet and Front Panels, Kick Plate or Sub Bases are available for most Tru-Fit™ Chassis Product Offerings.
Comitale National Inc.17
Nominal Cooling Capacity 3.5 Ton
Power Supply 208/230-60Hz1ph208/230-60Hz 3ph208/480-60Hz 3ph
Total Running Amps208/230-60Hz 1ph 29.0**208/230-60Hz 3ph 19.0**208/480-60Hz 3ph 10.5**
CNI provides condensing units for replacement orupdate of equipment originally installed for self contained Unit Ventilators. CNI manufactures condensing unit sections for the Nesbitt® SyncretizerPKG and Split System Unit Ventilators. The originalNesbitt® TP condensing unit was engineered specifically for the class room application and incorporated unmatched design and safety featuresrequired for this application. CNI today manufactures its products to these same high standards of excellence.
CNI Replacement for the Nesbitt®TP Condensing Sections
* Based on 95oF condensing temperature 80oF DB-67oF WB and80oF maximum air over fuses and nominal voltage.** Includes fans, compressor and accessories.
25 1/4
4819
TP Condensing Unit Engineering Data
LIQUID LINE
CONDENSER
LIQUID LINEFILTER DRIER
COMPRESSOR
DISCHARGE LINE
SUCTION LINE
THERMOSTATIC EXPANSION VALVE BULB
THERMOSTATIC EXPANSION
VALVE
EXTERNAL EQUALIZER
LINE
UNIT VENTILATOR HEAT TRANSFER
SURFACE
CONDENSING SECTION
UNIT VENTILATOR SECTION
S E C T I O N 3
Comitale National Inc.18
Institutional Quality• constructed of 18 gauge sheet metal minimum• fully insulated terminal & electrical components
Low Installed Cost• the sleeve (42” x 16”) matches the standardbrick& block module
• outdoor louvers are shipped pre-installed onsleeve
• the slide-in chassis plugs into a special outletprovided with the sleeve
• a flat or slope top front enclosure, completewith discharge grille
Minimum Maintenance• filters readily available behind front panel
Low Energy Consumption• condenser coils-lanced fin rifle tubing, largersurface area
Low Noise Level• a true 2 speed motor lower DB levels• discharge and suction line muffler
Easy Installation• 2 major components, wall sleeve and chassis
Four Season Use• DX Cooling, electric, hydronic or steam heat
Weatherproof• clear anodized outdoor louver
How many of these benefits do you want in your packagedterminal air conditioner/heat pump:
Details & Dimensions
C
A SLEEVE
D
ACCESS DOOR LOCATED ON LEFT SIDE ON MODEL 22/24
BSLEEVE
D E
3/4 LOUVER
2
A Complete Packaged Terminal Air Conditioner/Heat Pump from 7000 BTUH up to 24,000 BTUH
For new construction, planand specification,
as well as design-build.
The PC-PH™ Series
Madein USA
Sleeve With Sleeve With LouverModel A B C D E Only Extension Frame
7 thru 18 MBH 42 16 5 3⁄4 16 5 5⁄8 42 1⁄4 x 16 1⁄4 42 7⁄16 x 16 1⁄2 42 11⁄16 x 16 3⁄4
22 thru 24 MBH 50 20 6 18 3⁄8 6 50 1⁄4 x 20 1⁄4 50 7⁄16 x 20 1⁄2 50 11⁄16 x 20 3⁄4
Wall Opening Guide
The Tru-Fit™ Seriesreplacement chassis--
The answer to all your thru the wall needs.
Available in Efficient Heat Pump Configuration. *Note CNI can also replace Amana®, Carrier® 52 Series, Fedders® FPTH and FPTA,
Friedrich® PE and PH, and General Electric® AZ Series. *Consult factory on the above units.
Consult factory for products not listed.
Comitale National, Inc.Family owned and operated for three generations.
• Adirondack-Aire®
• Airtemp®
• American Air Filter® Type 16,WY and YY
• American Air Filter® Type 25,GXY and XY
• American Standard® Type 41, 45and SG45
• Applied Comfort®• Beacon Morris®• Carteret® Type 45• Climate Master® 702, 703 and 704• Climatrol®• Climazone® UVK, UVW and UVY• Coastal Products® RB• Cold Point, Corp.®• Cool Heat® Type RM• Dunham Bush® Newport, III, IV and V• Embassy Weather Twin®
• Fedders® Unizone• Heil Quaker® Type SEA and SHA• Ice Air®
O.E.M. Replacement PartsIn stock for immediate delivery
From unit ventilators to rooftop systems
The PC-PH™ Series
For new construction,plan and specification,as well as design-build.
A complete packagedterminal Air
Conditioner/Heat PumpSizes ranging from 7,000
BTUH through 24,000 BTUH
Air Conditioner/Heat Pump
Make Your First Choice for HVACEquipment and Replacement Parts
• American Air Filter®• American Standard®
• Climatrol ®• Dunham Bush®
• Fedders Unizone®
• Ice Cap®
• Islandaire®
• Kapsis®• Lennox®
• MSI®• McQuay®
• Nesbitt®• Remington®
• RetroAire®
• Singer®• T.P.I.®• Westinghouse®
Building types include, but are not limited to:• Nursing Homes • Convalescent Centers• Hospitals • Hotels/Motels• Office Buildings • Schools/Universities
A low-cost alternative to all-season comfort conditioning.• More reliability • Easy installation• Quiet operation • Energy EfficientAn ideal component type system application for: