Part of Thermo Fisher Scientific Thermo Scientific Puffer Hubbard Laboratory Refrigerators and Freezers Unrivalled cold storage protection for valuable samples and materials Chromatography General Purpose Flammable Material Explosion-Proof Pharmacy Enzyme
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Part of Thermo Fisher Scientific
Thermo Scientific Puffer HubbardLaboratory Refrigerators and Freezers
Unrivalled cold storageprotection for valuable samples and materials
BRO-LECS-PFRHBD-0608.qxd 10.07.2008 17:22 Uhr Seite 1
2
Thermo Scientific Puffer HubbardLaboratory Refrigerators and Freezers
Unrivalled sampleprotection
Researchers worldwide protect more than two billion samples inside Thermo Scientific cold storageequipment. With proven solutions including +4°Crefrigerators to -196°C cryogenic freezers, rackingsystems and consumables, you're free to concentrate on your work without worrying about your valuablesamples.
BRO-LECS-PFRHBD-0608.qxd 10.07.2008 17:22 Uhr Seite 2
Reliable, dependable performance
• The Thermo ScientificCryoLogic™ microprocessorcontroller, available on all +4°C refrigerators and -20°Cor -30°C lab freezers, controls,measures, compares, andreports cabinet operation withdigital accuracy
• All our refrigerator and freezercabinets, including space-savingundercounter and upright models,share design and technologyimprovements developed throughdecades of experience
Operating Range +1°C to +8°C to -20°C to -30°C
General Purpose Refrigerators •Chromatography Refrigerators •Flammable Material Refrigerators • •Pharmacy Refrigerators •General Purpose Freezers • •Explosion-Proof Freezers •Enzyme Freezers •
Typical Use and Storage ApplicationsGeneral Storage • • •Reagents and Kits •Enzymes and Temperature Sensitive Materials •Chromatography Apparatus and Instrumentation •Test Samples • • •Biologicals • • •Culture Media •Patient Medication •BOD Protocols •Pre-Freezing • •Vaccines • • •Shelf Life Testing •
For critical storage applications, full alarm models with optional temperature recorders are strongly recommended.
3
ion
page page
page page
10 12Enzyme 14Lab Freezers
18Flammable
page22Accessories
20Explosion-Proof
page 16Economy
BRO-LECS-PFRHBD-0608.qxd 10.07.2008 17:22 Uhr Seite 3
CryoLogic control panel is standard on Puffer Hubbard refrigerators and freezers (except IRI models).
ModularControl DesignSelf-contained controlhousing integrated intomain control panel forefficient maintenance,as required
Setpoint SecurityKey-operated triple position switchfor main power and alarm; locks intemperature and alarm setpoints tominimize setpoint error and preventtampering
CryoLogic GuideOffers information at-a-glance for all
control and display functionsMicroprocessor-Based ControlCryoLogic microprocessor managessetpoint and actual conditions to providethe highest level of security for thestored product
Instrument-Grade ComponentsElectronic components and sub-systems are selectedfor performance and reliability under demandinglaboratory conditions
Service ParametersTouchpad sequence allows override access to controlfunction defaults for troubleshooting functions
Power Down ModeDuring power failure digital display
dims to conserve backup battery
Thermo Scientific Puffer Hubbard lab refrigerators and freezers includeenhanced digital electronic technology designed to simplify operation anddeliver greater accuracy.• Icon-based controls and displays include graphic references for universal operation
• Setpoint security with key-operated triple-position master switch controls power to allsystems for added safety
• A graphic thermometer confirms proper operation at-a-glance, shows normal, high or lowtemperature condition; steady green for normal, flashing top bar for overtemperature,flashing bulb for undertemperature
• Auto defrost models feature an advanced defrost sensor which manages the defrost cycle,minimizing trace amounts of frost build-up to maintain refrigeration coil efficiency
Overtemperature continuous* slow flash, icon only yes
Undertemperature continuous* slow flash, icon only yes
Power Loss continuous* slow flash, icon only yes
Door Ajar delay no
Low Battery no no
Service Required no no
Audible and visual warnings for door ajar, low alarm battery, system maintenance and power failure provide immediate status of critical functions. A push-button alarm testverifies sensor continuity, while the battery backup assures system readiness. The enlarged digital display improves visibility, taking the guesswork out of setpoint andperformance management.
*Mute will silence audible alarm with 6-minute ring back interval; display remains flashing. Moving triple position key switch to middle position disables alarm and audibleand visual warnings.
BRO-LECS-PFRHBD-0608.qxd 10.07.2008 17:22 Uhr Seite 4
5
GraphicThermometerEasy to view,shows normal, highor low temperaturecondition; steadygreen for normal,flashing top bar forovertemperature, flashing bulb forundertemperature
Digital DisplayIndicates cabinet temperature duringnormal operation,flashes during alarmcondition or setpointadjustment. Displaysother values withtouchpad sequence
Audible AlarmAudible and visual indicators areactivated in the event of warm,cold or power loss conditions.Mute will silence audible alarmwith 6 minute ring back interval;display remains flashing
Interior Light SwitchEnables interior lightingsystem (on applicablemodels)
Power Failure IconIlluminated when mainpower is interrupted
Service RequiredIlluminated when
controller is inprogramming mode,
or if simulated warmor cold conditions fail
to occur duringalarm test function
Door Ajar Illuminated whendoor is left openand alarm is in“active” mode(not available on45.8 cu.ft. (1297 L)sliding glass doormodels)
Battery BackupContinuous charge provides full alarmfunction in case ofpower failure
Low Battery AlarmIlluminated when thealarm system batterybackup charge is low
TouchpadData EntryIncreases or decreasessetpoint valuesin programmingmode
Touchpad Scan Changes main display; also used to access various programming andservice functions (alarm mute, recall 6 minutes)
Alarm Test Pressing “up” and “scan” buttonscreates simulated overtemperature andundertemperature condition and activatesaudible and visual alarms; display flashesmomentarily when test is complete
Laboratory QualityCabinet ConstructionOur refrigerators and freezers areavailable in 10 sizes, from compact4.9 cu.ft. (133 L) undercountermodels to spacious, triple-door78.8 cu.ft. (2231 L) cabinets. Allmodels are built to meet UL, CUL,and CE standards for safety.
• Hermetically sealed refrigeration compressor, air-cooled condenserand automatic condensateremoval for auto defrost models
• An efficient, high-capacity aircirculation system optimizestop-to-bottom temperatureuniformity, acceleratestemperature recoveryfollowing door openings, andaccommodates insertion ofwarm product
• Depending on model selection,standard or optional shelves,drawers, temperature recorders,cabinet casters and otheraccessories are available to meetmost laboratory needs
Laboratory Refrigerator and Freezer Selection Guide
Our chromatography refrigerators feature the CryoLogicmicroprocessor control system,positive airflow systems, industrialquality cabinet construction andextra-strength refrigerationcompressors selected for industrial,clinical and scientific use.
CryoLogic Microprocessor Control
Our FC series refrigerators featureenhanced digital electronictechnology designed to simplifyoperation and deliver greateraccuracy (see pages 4 and 5).
• Adjustable temperature control,range +1°C to +8°C, factorypre-set to +4°C
• Icon-based controls and displays include graphic references foruniversal operation
• Setpoint security with key-operated triple-position masterswitch controls power toall systems for added safety
• Audible/visual warnings for over-temperature, undertemperatureand power failure, with visualstatus reports on criticalfunctions
• Graphic thermometer confirmsproper operation at-a-glance,shows normal, high or lowtemperature condition; steadygreen for normal, flashing top barfor overtemperature, flashingbulb for undertemperature
• Advanced defrost sensormanages the defrost cycle,minimizing trace amounts of frostbuild-up to maintain refrigerationcoil efficiency
• Enlarged digital display,resolution to within 0.1°C,improves visibility
• Push-button alarm test verifies sensor continuity
• Battery backup assures controlpanel function during powerfailure
• Remote alarm contacts areincluded on all models
Our chromatographyrefrigerators are designedfor a variety of applicationsrequiring close temperaturecontrol, full access tochromatographyinstrumentation and easyset-up of instrumentationand apparatus within thechamber.
6
FC475 chromatography refrigerator. Casters and glass doors arestandard. Shown with optional temperature recorder.
BRO-LECS-PFRHBD-0608.qxd 10.07.2008 17:22 Uhr Seite 6
Cabinet Constructionand Performance• All refrigeration and control
systems are top-mounted(except sliding glass door modelFC445, base mounted)
• Door lock provision on all models
• One duplex vapor-proof interioroutlet, continuous on; separatepower cord provided
• Door-activated light switchon all models except FC445
• Model FC445 has independentswitch activated lights only
• Epoxy coated, open wire shelves,adjustable in 1" (25 mm)increments; no tools required
• Multi-pane glass door(s) withspring loaded door closures anda 90° stay-open feature (exceptsliding door model FC445)
• Positive, forced-air circulationmaintains temperature uniformityat all shelf levels
• Interior and exterior surfaces are finished with a high-impactpowder paint coating
Refrigeration System• Heavy duty, industrial-grade,
hermetically sealed compressors
• Automatic defrost foroptimum cooling capacity
• Automatic condensate removal; no drain lines required
Optional Accessories• Voltage safeguard, free standing
• Temperature recorder, 6" (152mm) circular chart, 7-day drive
• Additional access port,2" (50 mm) diameter, with cover
• Stainless steel interior andexterior surfaces
• Additional shelves, full or half size
• Heated glass doors and doorswing variations available onmost models
7
ORDERING INFORMATION
Temperature Range: +1°C to +8°C, factory preset to +4°C (auto defrost)
Int. Dimensions* Ext. Dimensions*Cu.Ft. Voltage Amps/ Full Half H x D x W H x D x W Ship Weight
Model No. (L) (Hz) Breaker (Plug) Door Shelves Shelves inches (mm) inches (mm) lb (kg)
FC423A 23.3 115 (60) 9.4/15 (P1) single, glass 0 2 58.0 x 29.0 x 24.0 79.1 x 36.2 x 28.0 425 (193)FC423D (659) 208/230 (60) 6.0/15 (P4) (1470 x 730 x 610) (2010 x 920 x 720)FC430A 29.2 115 (60) 9.4/15 (P1) single, glass 0 2 58.0 x 29.0 x 30.0 79.1 x 36.2 x 34.0 435 (197)FC430D (827) 208/230 (60) 6.0/15 (P4) (1470 x 730 x 760) (2010 x 920 x 870)FC445A 45.8 115 (60) 15.0/20 (P2) double, sliding, glass 4 2 58.0 x 26.0 x 52.5 79.1 x 33.0 x 56.5 670 (304)FC445D (1297) 208/230 (60) 8.5/15 (P4) (1470 x 660 x 1330) (2010 x 840 x 1440)FC450A 51.1 115 (60) 15.0/20 (P2) double, glass 4 2 58.0 x 29.0 x 52.5 79.1 x 36.2 x 56.5 580 (263)FC450D (1447) 208/230 (60) 8.5/15 (P4) (1470 x 730 x 1330) (2010 x 920 x 1440)FC475A 78.8 115 (60) 16.0/20 (P2) triple, glass 8 2 58.0 x 29.0 x 81.0 79.1 x 36.2 x 85.0 965 (438)FC475D (2231) 208/230 (60) 10.5/15 (P4) (1470 x 730 x 2050) (2010 x 920 x 2160)
Chromatography Refrigerators
* Published interior volumes are nominal; useable cu.ft. (L) capacities may be offset by shelves, drawers, blower coils, or cabinet protrusions. For specific cabinet dimensions and allowances, or for verification of clearancetolerances, contact our sales representative. Product performance may be affected by ambient temperature conditions, humidity conditions, sample loading preferences, and frequency of door openings. Contact our salesrepresentative for specific inquiries regarding your application.
FC445 chromatography refrigeratorwith sliding glass doors as standard.
Shown with optional temperature recorder.
BRO-LECS-PFRHBD-0608.qxd 10.07.2008 17:22 Uhr Seite 7
Our LR series refrigerators featurethe CryoLogic microprocessor controlsystem, positive airflow systems,industrial quality cabinet constructionand extra-strength refrigerationcompressors selected for industrial,clinical and scientific use.
IntrLogic Microprocessor Control
Our LR series lab refrigeratorsfeature enhanced digital electronictechnology designed to simplifyoperation and deliver greateraccuracy (see pages 4 and 5).
• Adjustable temperature control,range +1°C to +8°C, factorypre-set to +4°C
• Icon-based controls and displays include graphic references foruniversal operation
• Setpoint security with key-operated triple-position masterswitch controls power toall systems for added safety
• Audible/visual warnings for over-temperature, undertemperatureand power failure, with visualstatus reports on criticalfunctions
• Graphic thermometer confirmsproper operation at-a-glance,shows normal, high or lowtemperature condition; steadygreen for normal, flashing top barfor overtemperature, flashingbulb for undertemperature
• Advanced defrost sensormanages the defrost cycle,minimizing trace amounts of frostbuild-up to maintain refrigerationcoil efficiency
• Enlarged digital display,resolution to within 0.1°C,improves visibility
• Push-button alarm test verifies sensor continuity
• Battery backup assures controlpanel function during powerfailure
• Remote alarm contacts areincluded on all models
Our selection of generalpurpose laboratoryrefrigerators offers cabinetsizes to fit a variety of spaceneeds and storage volumerequirements.
8
Left to right: Models LR423, LR44 and LR450. Shown with optional casters and temperature recorders.Optional glass doors are available, except on undercounter models. Model LR44 shown with optionalfinished countertop.
LR44 undercounter refrigerator.
BRO-LECS-PFRHBD-0608.qxd 10.07.2008 17:22 Uhr Seite 8
• Full-view glass doors, doublepane construction (standardon LR445)
• Heated glass doors and doorswing variations are availableon most models
• Finished countertop for LR44
9
ORDERING INFORMATION
* Published interior volumes are nominal; useable cu.ft. (L) capacities may be offset by shelves, drawers, blower coils, or cabinet protrusions. For specific cabinet dimensions and allowances, or for verification of clearancetolerances, contact our sales representatives. Product performance may be affected by ambient temperature conditions, humidity conditions, sample loading preferences, and frequency of door openings. Contact our salesrepresentatives for specific inquiries regarding your application.
LR450 refrigerator shownwith optional casters and
temperature recorder.
Temperature Range: +1°C to +8°C, factory preset to +4°C (auto defrost)
Int. Dimensions* Ext. Dimensions*Cu.Ft. Voltage Amps/ H x D x W H x D x W Ship Weight
Model No. (L) (Hz) Breaker (Plug) Cabinet Door Shelves inches (mm) inches (mm) lb (kg)
LR44A 4.9 115 (60) 8.0/15 (P1) undercounter single, 3 20.0 x 20.0 x 20.0 33.4 x 26.0 x 24.0 212 (96)(133) solid (500 x 500 x 500) (850 x 660 x 610)
LR412A 11.5 115 (60) 9.4/15 (P1) space single, 4 52.0 x 21.0 x 20.0 71.9 x 28.8 x 24.0 280 (127)(326) saver solid (1320 x 530 x 500) (1830 x 740 x 610)
LR423A 23.3 115 (60) 9.4/15 (P1) upright single, 4 58.0 x 29.0 x 24.0 77.5 x 35.5 x 28.0 405 (184)LR423D (659) 208/230 (60) 6.0/15 (P4) solid (1470 x 730 x 610) (1970 x 910 x 720)LR430A 29.2 115 (60) 9.4/15 (P1) upright single, 4 58.0 x 29.0 x 30.0 77.5 x 35.5 x 34.0 435 (197)LR430D (826) 208/230 (60) 6.0/15 (P4) solid (1470 x 730 x 760) (1970 x 910 x 870)LR445A 45.8 115 (60) 15.0/20 (P2) upright double, 8 58.0 x 26.0 x 52.0 77.5 x 35.0 x 56.5 670 (304)LR445D (1297) 208/230 (60) 8.5/15 (P4) sliding glass (1470 x 660 x 1320) (1970 x 890 x 1440)LR450A 51.1 115 (60) 15.0/20 (P2) upright double, 8 58.0 x 29.0 x 52.0 77.5 x 35.5 x 56.5 585 (265)LR450D (1447) 208/230 (60) 8.5/15 (P4) solid (1470 x 730 x 1320) (1970 x 910 x 1440)LR475A 78.8 115 (60) 16.0/20 (P2) upright triple, 12 58.0 x 29.0 x 81.0 77.5 x 35.5 x 85.0 805 (365)LR475D (2231) 208/230 (60) 10.5/15 (P4) solid (1470 x 730 x 2050) (1970 x 910 x 2160)
General Purpose Laboratory Refrigerators
BRO-LECS-PFRHBD-0608.qxd 10.07.2008 17:22 Uhr Seite 9
Our RX series pharmacyrefrigerators feature the CryoLogicmicroprocessor control system,positive airflow systems, industrialquality cabinet construction andextra-strength refrigerationcompressors selected for industrial,clinical and scientific use.
CryoLogic Microprocessor Control
Our RX pharmacy refrigeratorsfeature enhanced digital electronictechnology designed to simplifyoperation and deliver greateraccuracy (see pages 4 and 5).
• Adjustable temperature control,range +1°C to +8°C, factorypre-set to +4°C
• Icon-based controls and displays include graphic references foruniversal operation
• Setpoint security with key-operated triple-position masterswitch controls power toall systems for added safety
• Audible/visual warnings for over-temperature, undertemperatureand power failure, with visualstatus reports on criticalfunctions
• Graphic thermometer confirmsproper operation at-a-glance,shows normal, high or lowtemperature condition; steadygreen for normal, flashing top barfor overtemperature, flashingbulb for undertemperature
• Advanced defrost sensormanages the defrost cycle,minimizing trace amounts of frostbuild-up to maintain refrigerationcoil efficiency
• Enlarged digital display,resolution to within 0.1°C,improves visibility
• Push button alarm test verifies sensor continuity
• Battery backup assures controlpanel function during powerfailure
• Remote alarm contacts areincluded on all models
Configured for accurate storage and easyretrieval of pharmacy products, our RXSeries pharmacy refrigerators feature fullextension stainless steel roll-out drawers.Developed for stable temperature controlover a range of +1°C to +8°C, theserefrigerators are available in three sizes.
10
Our pharmacy refrigerators aredesigned to provide stable
temperature control and allowefficient inventory management.
Model shown: RX430 with fullextension roll-out drawers and
full view glass door.
BRO-LECS-PFRHBD-0608.qxd 10.07.2008 17:22 Uhr Seite 10
Cabinet Constructionand Inventory System• Full extension stainless steel
drawers, fully adjustable
• Full view glass door(s), doublepane construction eliminatescondensation; spring-loadedclosures include 90o stay openfeature
• Heated glass doors and doorswing variations available onmost models
11
ORDERING INFORMATION
* Published interior volumes are nominal; useable cu.ft. (L) capacities may be offset by shelves, drawers, blower coils, or cabinet protrusions. For specific cabinet dimensions and allowances, or for verification of clearancetolerances, contact our sales representative. Product performance may be affected by ambient temperature conditions, humidity conditions, sample loading preferences, and frequency of door openings. Contact our salesrepresentative for specific inquiries regarding your application.
Temperature Range: +1°C to +8°C, factory preset to +4°C (auto defrost)
Int. Dimensions* Ext. Dimensions*Cu.Ft. Voltage Amps/ H x D x W H x D x W Ship Weight
Model No. (L) (Hz) Breaker (Plug) Cabinet Door Drawers inches (mm) inches (mm) lb (kg)
RX423A 23.3 115 (60) 9.4/15 (P1) upright single, 6 58.0 x 29.0 x 24.0 77.5 x 35.5 x 28.0 470 (213)RX423D (659) 208/230 (60) 6.0/15 (P4) glass (1470 x 730 x 610) (1970 x 910 x 720)RX430A 29.2 115 (60) 9.4/15 (P1) upright single, 6 58.0 x 29.0 x 30.0 77.5 x 35.5 x 34.0 505 (227)RX430D (826) 208/230 (60) 6.0/15 (P4) glass (1470 x 730 x 760) (1970 x 910 x 870)RX450A 51.1 115 (60) 15.0/20 (P2) upright double, 12 58.0 x 29.0 x 52.0 77.5 x 35.5 x 56.5 790 (359)RX450D (1447) 208/230 (60) 8.5/15 (P4) glass (1470 x 730 x 1320) (1970 x 910 x 1440)
Pharmacy Refrigerators
BRO-LECS-PFRHBD-0608.qxd 10.07.2008 17:22 Uhr Seite 11
12
Thermo ScientificPuffer HubbardIEN/IGL Series -20°C Enzyme andGeneral LaboratoryFreezers
Featuring CryoLogicMicroprocessorControl
Our -20°C freezers feature theCryoLogic microprocessor controlsystem, gravity air circulation,industrial quality cabinetconstruction, and extra-strengthrefrigeration compressors selectedfor industrial, clinical and scientificuse.
The IEN2023 enzyme freezerfeatures an easily accessibleinventory system, while theIGL2023 general lab freezer offersflexible utility value with fourwireshelves.
CryoLogic Microprocessor Control
Our -20°C enzyme and laboratoryfreezers feature enhanced digitalelectronic technology designed tosimplify operation and deliver greateraccuracy (see pages 4 and 5).
• Pre-set -20°C operation
• Icon-based controls and displays include graphic references foruniversal operation
• Setpoint security with key-operated triple-position masterswitch controls power toall systems for added safety
• Audible/visual warnings for over-temperature, undertemperatureand power failure, with visualstatus reports on criticalfunctions
• Graphic thermometer confirmsproper operation at-a-glance,shows normal, high or lowtemperature condition; steadygreen for normal, flashing top barfor overtemperature, flashingbulb for undertemperature
• Enlarged digital display,resolution to within 0.1°C,improves visibility
• Push button alarm test verifies sensor continuity
• Battery backup assures controlpanel function during powerfailure
• Remotealarmcontacts arestandard onall models
Our manual defrost -20°Cupright freezers are designed forstorage applications whereslight intermittent coil warmingduring an auto defrost cycle isnot desired. Two models featuregravity convection air systemsfor maximum stability withoutblowers or fans.
The -20°C IEN2023 enzyme freezerstores 45 enzyme bins on 9 shelves.Shown with optional casters andtemperature recorder.
High impact plastic enzymestorage bins enable easily
accessible, highly concentratedinventory storage. Additionalbins are useful for managing
loose material in generalpurpose applications; see
Accessories section.
BRO-LECS-PFRHBD-0608.qxd 10.07.2008 17:22 Uhr Seite 12
13
ORDERING INFORMATION
Temperature Range: -20°C (manual defrost)
Int. Dimensions* Ext. Dimensions*Cu.Ft. Voltage Amps/ H x D x W H x D x W Ship Weight
Model No. (L) (Hz) Breaker (Plug) Cabinet Door Shelves inches (mm) inches (mm) lb (kg)
IEN2023A 23.3 115 (60) 13.5/20 (P2) upright single, 9 58.0 x 29.0 x 24.0 77.5 x 35.5 x 28.0 425 (193)IEN2023D (659) 208/230 (60) 5.6/15 (P4) solid (1470 x 730 x 610) (1970 x 910 x 720)
Enzyme Freezers
* Published interior volumes are nominal; useable cu.ft. (L) capacities may be offset by shelves, drawers, blower coils, or cabinet protrusions. For specific cabinet dimensions and allowances, or for verification of clearancetolerances, contact our sales representative. Product performance may be affected by ambient temperature conditions, humidity conditions, sample loading preferences, and frequency of door openings. Contact our salesrepresentative for specific inquiries regarding your application.
Temperature Range: -20°C (manual defrost)
Int. Dimensions* Ext. Dimensions*Cu.Ft. Voltage Amps/ H x D x W H x D x W Ship Weight
Model No. (L) (Hz) Breaker (Plug) Cabinet Door Shelves inches (mm) inches (mm) lb (kg)
IGL2023A 23.3 115 (60) 13.5/20 (P2) upright single, 4 58.0 x 29.0 x 24.0 77.5 x 35.5 x 28.0 425 (193)IGL2023D (659) 208/230 (60) 5.6/15 (P4) solid (1470 x 730 x 610) (1970 x 910 x 720)
Our -30°C general laboratoryfreezers are designed for medicaland scientific applications suchas storage of reagents,pharmaceuticals, biologicals, or other commonly usedlaboratory materials. Modelsoffer cabinet sizes to fit a varietyof space needs and storagevolume requirements.
IUF3050 (left) and IUF3023 (right) -30°C freezers, shownwith optional casters and temperature recorder.
Our freezers feature the CryoLogicmicroprocessor control system,positive airflow systems, industrialquality cabinet construction andextra-strength refrigerationcompressors selected for industrial,clinical and scientific use.
CryoLogic Microprocessor Control
Our IUF series lab freezers feature enhanced digital electronictechnology designed to simplifyoperation and deliver greateraccuracy (see pages 4 and 5).
• Pre-set -30°C operation
• Icon-based controls and displays include graphic references foruniversal operation
• Setpoint security with key-operated triple-position masterswitch controls power toall systems for added safety
• Audible/visual warnings for over-temperature, undertemperatureand power failure, with visualstatus reports on criticalfunctions
• Graphic thermometer confirmsproper operation at-a-glance,shows normal, high or lowtemperature condition; steadygreen for normal, flashing top barfor overtemperature, flashingbulb for undertemperature
• Advanced defrost sensormanages the defrost cycle,minimizing trace amounts of frostbuild-up to maintain refrigerationcoil efficiency
• Enlarged digital display,resolution to within 0.1°C,improves visibility
• Push button alarm test verifies sensor continuity
• Battery backup assures controlpanel function during powerfailure
• Remote alarm contacts areincluded on all models
BRO-LECS-PFRHBD-0608.qxd 10.07.2008 17:22 Uhr Seite 14
15
ORDERING INFORMATION
* Published interior volumes are nominal; useable cu.ft. (L) capacities may be offset by shelves, drawers, blower coils, or cabinet protrusions. For specific cabinet dimensions and allowances, or for verification of clearancetolerances, contact our sales representative. Product performance may be affected by ambient temperature conditions, humidity conditions, sample loading preferences, and frequency of door openings. Contact our salesrepresentative for specific inquiries regarding your application.
Temperature Range: -30°C (auto defrost)
Int. Dimensions* Ext. Dimensions*Cu.Ft. Voltage Amps/ H x D x W H x D x W Ship Weight
Model No. (L) (Hz) Breaker (Plug) Cabinet Door Shelves inches (mm) inches (mm) lb (kg)
IUF3004A 4.9 115 (60) 8.0/15 (P1) undercounter single, 3 20.0 x 20.0 x 20.0 33.4 x 26.0 x 24.0 212 (96)(133) solid (500 x 500 x 500) (850 x 660 x 610)
IUF3012A 11.5 115 (60) 8.0/15 (P1) space single, 4 52.0 x 21.0 x 20.0 71.9 x 28.8 x 24.0 280 (127)(326) saver solid (1320 x 530 x 500) (1830 x 740 x 610)
IUF3023A 23.3 115 (60) 16.0/20 (P2) upright single, 58.0 x 29.0 x 24.0 77.5 x 35.5 x 28.0 370 (168)IUF3023D (659) 208/230 (60) 12.0/15 (P4) solid 4 (1470 x 730 x 610) (1970 x 910 x 720)IUF3030A 29.2 115 (60) 16.0/20 (P2) upright single, 58.0 x 29.0 x 30.0 77.5 x 35.5 x 34.0 445 (202)IUF3030D (826) 208/230 (60) 12.0/15 (P4) solid 4 (1470 x 730 x 760) (1970 x 910 x 870)IUF3050A 51.1 115 (60) 16.0/20 (P2) upright double, 58.0 x 29.0 x 52.0 77.5 x 35.5 x 56.5 600 (272)IUF3050D (1447) 208/230 (60) 12.0/15 (P4) solid 8 (1470 x 730 x 1320) (1970 x 910 x 1440)
General Purpose Laboratory Freezers
Cabinet Constructionand Inventory System• Cabinet capacities from
Model IUF3004A undercounter freezer,shown with optional finished counter top
BRO-LECS-PFRHBD-0608.qxd 10.07.2008 17:23 Uhr Seite 15
16
Thermo ScientificPuffer HubbardEconomy Series andGeneral PurposeRefrigerators,Freezers andCombinations
Refrigerators and Combinations
• Adjustable operating temperature:+2°C to +10°C
• Sliding glass door models haveeight adjustable wire shelves;other models have high-strengthshelves with interior door shelvingfor added inventory capacity
• Durable, white acrylic exteriorfinish; corrosion-resistantseamless interior
• Dual pane, sliding glass doors;other models feature magneticdoor gaskets for positive seal.14.0 and 20.7 cu. ft. modelsfeature a built-in door lock
• Other features: Swing glass doormodel - two fluorescent lightswith on/off switches, optionalaccess port and free-standingtemperature recorder. LargeCapacity models – interiorthermometer
Laboratory Freezers
• Adjustable operating temperature:-12°C to -20°C
• Manual defrost of -4.7 cu. ft. to20.7 cu. ft; -29.2 cu. ft. (automaticdefrost)
• Internal thermometer temperaturedisplay on upright models
• High-strength, non-adjustableshelf inventory system plus doorshelving for increased storagecapacity
• Quiet, hermetically-sealedcompressor refrigerator system
• Manual defrost (except IUF1829Awhich has automatic defrost)
• High-density, urethane foaminsulation
• Magnetic door gaskets forpositive seal. Additional featureson 14.5 and 20.7 cu. ft. modelsinclude 90° stay-open stops and akeyed door lock
• Durable white acrylic exterior,corrosion-resistant seamlessinterior
Thermo Scientific PufferHubbard laboratory refrigeratorsand freezers are an economicalchoice for common non-criticallaboratory requirements. Modelsprovide dependable refrigerationsystems and quality cabinetconstruction with basic controlfeatures.
Laboratory Refrigerators, left to right: Models ILR443 and GLR431
Economic Solutionsfor Safe Cold Storage
BRO-LECS-PFRHBD-0608.qxd 10.07.2008 17:23 Uhr Seite 16
Optional Accessories Catalog No.
1" porthole with cover 6105Digital LCD solar temperature displaydoor mounted (factory installed) 7114Key lock (factory installed) 6186Key lock with hasp (factory installed) 7208
17
ORDERING INFORMATION
Int. Dimensions* Ext. Dimensions*Cu.Ft. Voltage Amps/ Style/ Shelves Shelves H x D x W H x D x W
Model No. (L) (Hz) Breaker (Plug) Door Interior Door inches (mm) inches (mm)
ILR416A 14.0 115 1.8 Upright/ 3 6 51.5 x 18 x 27 65.5 x 26.5 x 32(396) (60) 15 Solid (1310 x 460 x 690) (1660 x 670 x 813)
ILR421A 20.7 115 1.8 Upright/ 4 6 57 x 23 x 27 70.2 x 28.5 x 32(586) (60) 15 Solid (1450 x 580 x 690) (1780 x 720 x 810)
ILR429A 29.2 115 5.7 Upright/ 4 6 65.1 x 28 x 32 76.25 x 31.6 x 35(827) (60) 15 Solid (1654 x 711 x 812) (1940 x 802 x 889)
GLR431A* 28.9 115 7.2 Upright/ 4 0 65.1 x 24 x 32 76.25 x 32 x 36.3(818) (60) 15 Glass (1654 x 610 x 813) (1940 x 813 x 920)
ILR443A** 42.8 115 9.2 Upright/ 8 0 57 x 26.5 x 49 76 x 32 x 53(1212) (60) 20 Sliding Glass (1448 x 673 x 1245 ) (1930 x 813 x 1346)
General Purpose Refrigerators
Int. Dimensions* Ext. Dimensions*Cu.Ft. Voltage Amps/ Style/ Shelves Shelves H x D x W H x D x W
Model No. (L) (Hz) Breaker (Plug) Door Interior Door inches (mm) inches (mm)
ILR42A 2.1/59 ref. 115 2.3 Tabletop/ 3 6 ref. 15.3 x 14.7 x 16.3 (389 x 373 x 414) 19 x 20 x 18.50.3/8 frz. (60) 15 Solid frz. 6.5 x 11.3 x 8 (132 x 378 x 452) (482 x 508 x 470)
ILR45A 3.5/99 ref. 115 1.1 Undercounter/ 4 6 ref. 21.1 x 15.5 x 18.5 (536 x 394 x 470) 33.8 x 25.1 x 21.31.2/34 frz. (60) 15 Solid frz. 7.2 x 15 x 18.5 (183 x 381 x 470) (859 x 638 x 541)
ILR414A 9.8/278 ref. 115 2.1 Upright/Solid, 4 6 ref. 44.5 x 18.5 x 20.5 (130 x 470 x 521) 63 x 25.6 x 23.51.1/31 frz. (60) 15 Single Door frz. 8.9 x 12 x 18.1 (226 x 305 x 460) (1600 x 650 x 600)
DLR-411A 8.6/244 ref. 120 3.8 Upright/Solid, 4 6 ref. 41.75 x 17.25 x 20.75 (1060 x 438.2 x 527.1) 63 x 21.75 x 23.382.4/68 frz. (60) 15 Single Door frz. 12.63 x 17.38 x 19.38 (320.8 x 441.5 x 492.3) (1600 x 603.3 x 593.9)
Refrigerator/Freezer Combinationss
Ext. Dimensions*Cu.Ft. Voltage Amps/ Shelves Shelves H x D x W
Model No. (L) (Hz) Breaker (Plug) Interior Door inches (mm)
IUF1805A 4.7 115 1.0 2 3 33.8 x 25.1 x 21.3(133) (60) 15 (860 x 640 x 540)
IUF1816A 14.5 115 1.8 3 5 65.5 x 26.5 x 32(411) (60) 15 (1660 x 670 x 810)
IUF1821A 20.7 115 1.8 4 6 70.2 x 28.5 x 32(586) (60) 15 (1780 x720 x 810)
Laboratory Freezers (Manual Defrost)
Ext. Dimensions*Cu.Ft. Voltage Amps/ Shelves Shelves H x D x W
Model No. (L) (Hz) Breaker (Plug) Interior Door inches (mm)
IUF1829A 29.2 115 9.0 4 0 76.2 x 33.6 x 35(827) (60) 15 (1940 x 850 x 890)
Laboratory Freezers (Automatic Defrost)
* Casters standard, ** Casters optional, all others casters not available
Casters and extra shelving not available. 1" access port available as option.
BRO-LECS-PFRHBD-0608.qxd 10.07.2008 17:23 Uhr Seite 17
• Interior is corrosion-resistant,easy-to-clean and spark-proof
• Adjustable leveling feet
Door(s)
• Non-sparking magnetic gasket
• 17.3 and 20.7 cu. ft. modelsinclude keyed door lock
Electrical
• Power cord and plug provided forall models with 120 V, 60 Hzoperation, NEMA 5-15R/5-15P
Finish
• White acrylic, scratch-resistantexterior
Flammable material refrigeratorsand freezers are designed for storageof volatile materials but are notintended for use in hazardousareas. All models meet OSHAstandards and applicable ULrequirements. Access ports, castersand extra shelving are not availablefor flammable storage units.
18
Designed to ensure maximum safety for storageof flammable and volatile materials, ourrefrigerators, combination refrigerator/freezercabinets and -20°C freezers meet NFPA andOSHA standards and are UL listed. Allflammable material storage cabinets featureCFC-free, foamed-in-place cabinet insulation,hermetically sealed refrigeration compressorsand adjustable temperature control.
Flammable Material Storage Refrigerator/Freezer Combination: double door Model
FDR411A.
BRO-LECS-PFRHBD-0608.qxd 10.07.2008 17:23 Uhr Seite 18
19
ORDERING INFORMATION
Temperature Range: +2°C to +10°C (manual defrost)
Int. Dimensions* Ext. Dimensions*Cu.Ft. Voltage Amps/ Style/ Shelves Shelves H x D x W H x D x W Ship Weight
Model No. (L) (Hz) Breaker (Plug) Door Interior Door inches (mm) inches (mm) lb (kg)
FLR416A 14.5 115 5.0 Upright/ 3 5 51.5 x 18.0 x 27.0 65.2 x 30.0 x 32.0 235(411) (60) 15 Solid (1310 x 457 x 690) (1660 x 762 x 813) (107)
FLR421A 20.7 115 5.0 Upright/ 4 6 57.5 x 22.0 x 27.8 67.0 x 32.3 x 33.0 250(586) (60) 15 Solid (1460 x 559 x 706) (1702 x 821 x 838) (114)
Flammable Material Upright Refrigerators
Temperature Range: Refrigerator +2°C to +10°C, Freezer -12°C to -18°C (manual defrost)
Int. Dimensions* Ext. Dimensions*Cu.Ft. Voltage Amps/ Style/ Shelves Shelves H x D x W H x D x W Ship Weight
Model No. (L) (Hz) Breaker (Plug) Door Interior Door inches (mm) inches (mm) lb (kg)
FLR45A 5.1/144 ref. 115 0.9 Undercounter/ 3 3 21.1 x 19.5 x 19.0 (536 x 495 x 483) 33.6 x 25.9 x 21.3 78 (35)0.5/14 frz. (60) 15 Solid 5.2 x 15 x 17.8 (132 x 381 x 452) (853 x 658 x 541)
FDR411A 8.8/249 ref. 120 1.5/15 Upright/ 4 (ref.) 4 (ref.) 44.9 x 18.0 x 20.5 (1140 x 457 x 521) 67 x 25.4 x 23.5 151 (69)2.4/68 frz. (60) Solid Double Door 13.0 x 17.0 x 18.5 (330 x 432 x 470) (1701 x 644 x 597)
Flammable Material Upright Refrigerator/Freezer Combinations
Temperature Range: -12°C to -20°C (manual defrost)
Int. Dimensions* Ext. Dimensions*Cu.Ft. Voltage Amps/ Style/ Shelves Shelves H x D x W H x D x W Ship Weight
Model No. (L) (Hz) Breaker (Plug) Door Interior Door inches (mm) inches (mm) lb (kg)
FUF1804A 5.0 115 1.4 Undercounter/ 2 3 29 x 19.5 x 18.8 33.5 x 26.5 x 21.3 84 (38)(141) (60) 15 Solid (737 x 495 x 476) (851 x 673 x 541)
FUF1816A 16.0 115 2.0 Upright/ 3 5 50.5 x 22.0 x 25.3 61.0 x 33.3 x 30.0 235 (107)(453) (60) 15 Solid (1283 x 559 x 643) (1549 x 846 x 762)
FUF1821A 20.7 115 2.0 Upright/ 4 6 57.5 x 22.0 x 27.8 67.0 x 32.3 x 33.0 250 (114)(586) (60) 15 Solid (1461 x 559 x 706) (1702 x 821 x 838)
Flammable Material Upright Freezer
* Published interior volumes are nominal; useable cu.ft. (L) capacities may be offset by shelves, drawers, blower coils or cabinet protrusions. For specific cabinet dimensions and allowances, or for verification of clearancetolerances, contact your sales representative. Product performance may be affected by ambient temperature conditions, humidity conditions, sample loading preferences and frequency of door openings. Contact your salesrepresentative for specific enquiries regarding your application. Products are intended for basic laboratory use only. Storage of high-value life science materials or critical biologicals may require alarm, monitoring, backup andtemperature performance features. The need to add these features should be determined by your industrial hygienist or safety officer. Not suitable for corrosive environments.
BRO-LECS-PFRHBD-0608.qxd 10.07.2008 17:23 Uhr Seite 19
• Interior is corrosion-resistant,easy-to-clean and spark-proof
• Electrical components steel-encased
• Adjustable leveling feet
Door(s)
• Non-sparking magnetic gasket
• 14.5 and 20.7 cu. ft. modelsinclude keyed door lock
Electrical
• Must be hardwire connected inaccordance with local codes
Finish
• White acrylic, scratch-resistantexterior
Explosion proof refrigerators andfreezers must be hardwireconnected in accordance with localelectrical codes. Access ports,casters and extra shelving are notavailable for explosion proof units.All models are designed for safestorage of volatile materials inhazardous areas. All models meetNFPA and OSHA standards, andUL requirements for Class 1,Group C and D applications.
Our explosion proof refrigerators and freezers aredesigned to meet NFPA and OSHA standards forsafe storage of volatile materials. A variety of ULlisted cabinets offer capacities to fit an array ofspace and volume requirements. All electricalcomponents are steel-encased, and cabinetinteriors are spark-proof with a nonsparkingmagnetic door gasket. Foamed-in-place,CFC-free urethane insulation protects againsthigh ambient temperatures.
Explosion Proof Refrigerator/FreezerCombination: double door Model XDR411A.
BRO-LECS-PFRHBD-0608.qxd 10.07.2008 17:23 Uhr Seite 20
21
ORDERING INFORMATION
Temperature Range: +2°C to +10°C (manual defrost)
Int. Dimensions* Ext. Dimensions*Cu.Ft. Voltage Amps/ Style/ Shelves Shelves H x D x W H x D x W Ship Weight
Model No. (L) (Hz) Breaker (Plug) Door Interior Door inches (mm) inches (mm) lb (kg)
XLR416A 14.5 115 5.0 Upright/ 3 5 51.5 x 18.0 x 27.0 65.2 x 32.0 x 32.7 235(411) (60) 15 Solid (1310 x 457 x 686) (1660 x 810 x 830) (107)
XLR421A 20.7 115 5.0 Upright/ 4 6 57.5 x 22.0 x 27.8 67.0 x 34.8 x 33.0 250(586) (60) 15 Solid (1460 x 559 x 706) (1702 x 838 x 887) (114)
Explosion-Proof Refrigerators
Temperature Range: Refrigerator +2°C to +10°C, Freezer -12°C to -18°C (manual defrost)
Int. Dimensions* Ext. Dimensions*Cu.Ft. Voltage Amps/ Style/ Shelves Shelves H x D x W H x D x W Ship Weight
Model No. (L) (Hz) Breaker (Plug) Door Interior Door inches (mm) inches (mm) lb (kg)
XLR45A 5.1/144 ref. 115 0.9 Undercounter/ 3 (ref.) 3 (ref.) ref. 21.0 x 19.5 x 19.0 (533 x 495 x 483) 33.6 x 29.0 x 21.4 780.5/14 frz. (60) 15 Solid frz. 5.2 x 14.9 x 17.8 (132 x 378 x 452) (853 x 737 x 534) (35)
XDR411A 8.8/249 ref. 120 1.5 Upright/ 4 (ref.) 4 (ref) ref. 44.9 x 18.0 x 20.5 (1140 x 457x 521) 67 x 27.8 x 23.5 151 2.4/68 frz. (60) 15 Solid Double Door frz. 13.0 x 17.0 x 18.5 (330 x 432 x 470) (1701 x 705 x 597) (69)
Explosion-Proof Refrigerator/Freezer Combinations
Temperature Range: -12°C to -20°C Operating Temperature (manual defrost)
Int. Dimensions* Ext. Dimensions*Cu.Ft. Voltage Amps/ Style/ Shelves Shelves H x D x W H x D x W Ship Weight
Model No. (L) (Hz) Breaker (Plug) Door Interior Door inches (mm) inches (mm) lb (kg)
XUF1804A 5.0 115 1.4 Undercounter/ 2 3 29.0 x 19.5 x 18.8 33.5 x 28.8 x 21.3 84(141) (60) 15 Solid (737 x 495 x 476) (851 x 730 x 541) (38)
XUF1816A 16.0 115 2.0 Upright/ 3 5 50.5 x 22.0 x 25.3 61.0 x 35.9 x 30 235 (453) (60) 15 Solid (1243 x 559 x 643) (1549 x 913 x 762) (107)
XUF1821A 20.7 115 2.0 Upright/ 4 6 57.5 x 22.0 x 27.8 67.0 x 34.9 x 33.0 250(586) (60) 15 Solid (1461 x 559 x 706) (1702 x 887 x 838) (114)
Explosion-Proof Freezer
* Published interior volumes are nominal; useable cu.ft. (L) capacities may be offset by shelves, drawers, blower coils or cabinet protrusions. For specific cabinet dimensions and allowances, or for verification of clearancetolerances, contact your sales representative. Product performance may be affected by ambient temperature conditions, humidity conditions, sample loading preferences and frequency of door openings. Contact your salesrepresentative for specific enquiries regarding your application.
Products are intended for basic laboratory use only. Storage of high-value life science materials or critical biologicals may require alarm, monitoring, backup and temperature performance features.The need to add these features should be determined by your industrial hygienist or safety officer. Not suitable for corrosive environments.
BRO-LECS-PFRHBD-0608.qxd 10.07.2008 17:23 Uhr Seite 21
Surge SuppressorSurge suppressors provideadditional protection againstvoltage transients which maydamage refrigeration or controlcomponents. Independent modulerequires field installation by aqualified electrician or factoryauthorized service technician.Model number and voltage mustbe specified when ordering.
Catalog No. 6402
CastersCasters are optional on mostmodels. Casters are factoryinstalled when ordered at time ofcabinet order; customer installed ifordered separately. Choose from 2"(50 mm) or 3" (76 mm) casters.
Interior, Exterior and Countertop Finishes• Optional stainless steel interior
and/or exterior surfaces areavailable and must be specifiedwhen ordering
Finished countertop adds 1" (25 mm) to unit height.
22
Accessories
Voltages and Serial NumbersSerial number tags on all our PufferHubbard products contain modelnumbers and voltage informationneeded for accurate selection ofaccessories ordered for fieldinstallation.
• It is recommended thataccessories be ordered whenyour refrigerator or freezer isordered
• Factory-installed accessoriesallow proper set-up withoutpower-down or emptying the cabinet
Validation Testing ProgramValidation testing services inadvance of shipment canaccelerate in-house FDAInstallation Qualification (IQ) andOperation Qualification (OQ)programs. Validation servicesinclude documentation andperformance reports, compressorand sub-system componentspecifications, microprocessor flowdiagrams, software specificationsand more. For more details,contact your sales representative.
Certification of CalibrationControl, alarm and temperaturerecording systems aresystematically calibrated at thefactory for accurate performance.An optional Certificate ofCalibration to an NIST (NationalInstitute of Standards andTechnology, formerly NationalBureau of Standards) traceableinstrument includes a modelnumber and serial numbercertificate and single pointcalibration. Multiple pointcalibration is also available.Calibration certificates must berequested when ordering.
Catalog No. 6916-2
Voltage SafeguardHelps protect refrigerator orfreezer from damage by automati-cally boosting low voltage. Includesterminal board for direct wiring.Free-standing, field installed.
LH = Left Hand, RH = Right Hand Note: Glass doors are standard on selected blood bank, chromatography and pharmacy refrigerators; consult specificationchart for details. Sliding glass doors are standard on all 45.8 cu.ft. (1297 L) models. Heated glass doors will increase amperage and may require next sizebreaker.
BRO-LECS-PFRHBD-0608.qxd 10.07.2008 17:23 Uhr Seite 22
Thermo Scientific LabCooler™
Modules• The LabCooler II Benchtop Cooler
maintains enzymes at stable -20oC for up to two hours. Holds(24) 1.5 ml tubes and (8) 0.5 mltubes.
• The LabCooler Lite BenchtopCooler is smaller and morecompact, maintains enzymetemperatures at -10oC or below for up to one hour outsidethe freezer. Holds up to (7) 1.5 ml tubes. Includes a clearinterlocking top.
Cooler II Catalog No. 6744LabCooler Lite Catalog No. 6745
Temperature RecordersOptional 6" (152 mm) chart,7-day temperature recorders usepressure-sensitive chart paper; onebox of 50 charts included. Built-inrecorders must be specified whenordering.
Deluxe Electronic Remote AlarmThe deluxe electronic remote alarmcan be programmed to sound analarm in the event ofa temperature increase or powerfailure. • The alarm can dial up to
four telephone numbers
• Advises of an alarm conditionacross any telephone systemwhich accepts pulse dialing
• One system can monitor up tofour individual freezers or up tothree groups of freezers(available in 115V/60Hz only)
• Requires dedicated phone line
Catalog No. 6224
RemoteAlarm ModuleFor audible and visual signal in theevent of temperature rise or powerfailure. Can be located up to 1760feet (536 meters) from cabinet.Must be used with electronic alarmsystem and connected to normallyopen or normally closed remotealarm contacts. Wire not included.Specify refrigerator or freezervoltage when ordering (available in115V/60Hz only).
Catalog No. 5612-1A
Enzyme Storage BinBins are supplied standard onIEN2023 Enzyme Freezer.
Additional bins are useful forstorage and inventorymanagement. Formed of highimpact ABS plastic, off-white.Labels not included.
Catalog No. 6736
Alarm Delay Module
The alarm delay eliminates nuisancealarms due to intermittent ortransitory conditions such aslightning or brief power outages.
• Adjustable delay from 0.5 to32 minutes
• Red alarm indicator light remainsflashing after transient condition iscorrected; requires manual reset
• Signals chronic alarm conditionswhich may indicate impendingcomponent failure; allows timefor inspection or correctivemaintenance
• Inserts variable time intervalbetween detection of alarmcondition and transmission ofsignal
• Includes accurate digital timingcircuit adjustable from 0.5, 1, 2,4, 8, 18, or 32 minutes
• Operates independent of linepower; built-in battery and alarmtest function uses customersupplied 9V battery
Catalog No. 6903
Access PortAdditional port for probes, cables,leads or measuring instrumentsmay be added to any cabinet. Portis 1" (25 mm) diameter for freezersand 2" (50 mm) for refrigerators.Location must be specified whenordering. 2" for Refrigerators andFreezers.
Digital Temperature MonitorSimple, accurate and cost-effective,the digital temperature and powermonitor provides bothalarm/monitoring and digitaltemperature display in a single, self-contained unit. Standard featuresinclude high alarm, alarm mute andchirp, audio delay timer, remotealarm contacts (SPDT), NiCadbattery backup, and low voltage ACpower supply, 120V, AC.• The monitor can be installed on
or adjacent to any refrigerator orfreezer
• Activates an audible and visual warning in case of power failureor overtemperature condition
• Choose from single probe digital models or multiple probe,microprocessor-based models
• Temperature range is -100°C to+25°C
• Probe size 1.25"L x 0.25"diameter (32 mm x 6 mm)
Catalog No. 6898
Interior Dimensions (nominal)3.5"W (90 mm) x 3"H (76 mm) x 24"L (610 mm)
Exterior Dimensions (nominal)
4.4"W (112 mm) x 3.04"H (77 mm) x 25.25"L (641 mm)
CFC-Free Refrigerants, Insulation andPackagingAll our refrigerators and freezersuse CFC-free refrigerants, cabinetinsulation and packaging.
Product SelectionThis catalog is divided into sectionsaccording to general productapplication. Because most controllersallow adjustable setpoints, alltemperatures are listed as designoperating temperatures andtypically represent the lowest orcoldest temperature of atemperature range.
Electrical InformationThermo Scientific Puffer Hubbardrefrigerators and freezers aredesigned to meet UL, CUL, CE andTUV criteria for safety andperformance. All connections mustcomply with local electrical codes.
• Selection charts for each standardmodel list voltage, rated amperage,recommended circuit breaker size,and NEMA (National ElectricalManufacturers’ Association, USA)electrical plug information
• Most refrigerators and freezersare supplied with line cord plugs(P) which require correspondingreceptacles illustrated on the linecord plug reference chart to theright
• Site preparation requiresavailability of the proper receptacle;a dedicated circuit is recommended
• Special voltage selections may beavailable at extra cost and mustbe specified when ordering
Certification of CalibrationControl, alarm and temperaturerecording systems are systematicallycalibrated at the factory for accurateperformance. An optional Certificateof Calibration to an NIST (NationalInstitute of Standards andTechnology, formerly NationalBureau of Standards) traceableinstrument includes a ModelNumber and Serial NumberCertificate (single point calibration).Multiple point calibration is alsoavailable. Calibration certificatesmust be requested when ordering;for details contact our salesrepresentatives.
Validation Testing ProgramValidation testing services inadvance of shipment can acceleratein-house FDA InstallationQualification (IQ) and OperationQualification (OQ) programs.Validation services includedocumentation and performancereports, compressor and sub-system component specifications,microprocessor flow diagrams,software specifications and more.For more details, contact yoursales representatives.
Performance DataFor detailed performanceinformation such as temperaturerecovery, power consumption andother model-specific operationalcharacteristics, contact your salesrepresentatives.
Ordering InformationOur sales representatives willassist in choosing the properrefrigerator or freezer for yourapplication.
• Each model number is voltagespecific. For clarity, please includethe voltage of your selectedrefrigerator or freezer whenordering
• When ordering your refrigeratoror freezer, please consider currentor future accessory requirementssuch as temperature recorders,extra shelves andalarm/monitoring systems
• Many accessories are factoryinstalled and must be specifiedwhen ordering
Specifications
Models with have this require this NEMA Reference
this code plug receptacle Plug Receptacle
P1 5-15P 5-15R
P2 5-20P 5-20R
P3 5-30P 5-30R
P4 6-15P 6-15R
P5 6-20P 6-20R
P6 6-30P 6-30R
Line Cord Plug Reference
Refrigerators and freezers supplied with line cord plugs (P) requirecorresponding receptacles illustrated in the Line Cord Plug Reference. Catalogselection charts list each standard model with voltage, rated amperage,recommended circuit breaker size and NEMA electrical plug information.
BRO-LECS-PFRHBD-0608.qxd 10.07.2008 17:23 Uhr Seite 24