Thermo Scientific EPD TruDose Quick Start Guide Beta Window • Covers the β detector (Only the EPD TruDose G version has the cover cap) LCD Display • Shows parameters and/or functionality as selected by the buttons Sounder • Audible indicator of an alarm Navigate Button • Dual button design simplifies navigation, reduces training required to operate Battery Compartment • Front load, secured with screws in the back Detector Marking • Indicates EPD type: β – Beta γ - Gamma Select Button • Enables users to move through the menus and select functions Infrared Interface • Provides communication to/from the EPD Ultra Bright LED • Visible from the top and the front Label Recess • Place for color coding populations using COTS “dots” External Features For further operating instructions and Thermo Scientific™ EPD TruDose™ details, please refer to the User Manual.
4
Embed
Thermo Scientific EPD TruDose · Thermo Scientific EPD TruDose Quick Start Guide Beta Window • Covers the β detector (Only the EPD TruDose G version has the cover cap) LCD Display
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Thermo Scientific EPD TruDoseQuick Start Guide
Beta Window• Covers the β detector (Only the EPD TruDose G version
has the cover cap)
LCD Display• Shows parameters
and/or functionality as selected by the buttons
Sounder• Audible indicator of an
alarm
Navigate Button• Dual button design
simplifies navigation, reduces training required to operate
For further operating instructions and Thermo Scientific™ EPD TruDose™ details, please refer to the User Manual.
1. Unscrew battery hatch
Note battery polarity markings
2. Use battery hatch recess to open cover
3. Insert the battery
4. Replace battery hatch and reinsert screws.
Insert/Replace BatteryThe EPD TruDose should be worn under the direction of the Health Physicist. For most operating conditions, it is recommended that the EPD TruDose be worn on the outside of any protective clothing.
Note that the buttons should be facing outwards.
Attached to belt
Lanyard Worn inside breast pocket
Wearing
Select and Navigate Buttons
• Used to select a given display or action a command.
Navigate
Select
EPD TruDose Quick Start Guide
• Used to navigate from one display to another.
Lanyard Fixing
EPD Label
Clip Assembly
Alternative Lanyard Fixing
Display Menu Navigate Structure
Operations Power Off Clear DoseBluetooth
On/OffAudible/Visual Alarms On/Off
Hp10 Dose RateDose Alarm
Dose WarningDose Rate Alarm
Dose Rate
Warning
Total Dose (∑)
Peak Dose
Rate (Pk)
Hp07 Dose RateDose Alarm
Dose WarningDose Rate Alarm
Dose Rate
Warning
Total Dose
Peak Dose Rate
AssignmentWearer Name
Wearer ID#Task
NameTask#
Time Remaining
Time Remaining
% of total Hp10
dose received
Diagnostic Counts VersionCal Due
Date
Run Confirmation
Test
Alarm Demo
• Indicates Screen can be pinned; could be enabled as a Quick Access display
• Key Actions (e.g. Clear Dose, Turn Off, run conf test) require confirmation to execute (can’t be done accidentally)
EPD TruDose Quick Start Guide
LCD Display Layout
256.3µSvHp10
242.0mrem/hHp10
Example Dose Display
Example Rate Display
Measurement Display Layout
Units AreaNumeric AreaMeasurement Identity Area
Chrom
e RightC
hrom
e Le
ft
To Turn ON/OFF
Note: On display is used to prompt the user to turn the unit on. If no button is pressed during the 2 second timeout, the display will revert to the Off Mode Display.