AMS Ground Safety Review II Sept. 2008 – KSC 1

AMS 02 –Thermal Control

System Design

Thermal controlGSE at KSC

Page 2: Thermal control GSE at KSC

AMS Ground Safety Review II Sept. 2008 – KSC 2

AMS 02 –Thermal Control

System Design

TCS – GSE scope

• AMS at KSC will be in flight configuration (radiators)

• The TCS GSE shall allow the correct detector operation during the ground integration.

• The only GSE to be used at KSC will be electrically powered fans of two kind, to provide forced convection cooling.

• Several fans will blow air towards specific AMS components in order to keep their temperature in the operative range.

Page 3: Thermal control GSE at KSC

AMS Ground Safety Review II Sept. 2008 – KSC 3

AMS 02 –Thermal Control

System Design

Elements to be cooled

– Air cooling • Electronic crates and XPDs

– Main radiators (RAM and WAKE) mounted

• Cryocoolers (with LHP integrated, hence sunk to the zenith radiators)

• PDS (mounted on WAKE radiator)• CAB (with LHP integrated, hence sunk to the wake radiator)

• All other subdetectors don’t need forced convection cooling, free convection being sufficient.

Page 4: Thermal control GSE at KSC

AMS Ground Safety Review II Sept. 2008 – KSC 4

AMS 02 –Thermal Control

System Design

Type A Fans

• Quantity 12

• Diameter > 0.45 m

• Flow Rate 4100 m3/h

• Unit power (reference value) 135 W

• Voltage 110 V

• AC supply Frequency 60 Hz

Page 5: Thermal control GSE at KSC

AMS Ground Safety Review II Sept. 2008 – KSC 5

AMS 02 –Thermal Control

System Design

• Four fans will blow to the electronic units mounted on the Ram radiator, having their axis parallel to the radiator

• Four fans will blow to the electronic units mounted on the Wake radiator , having their axis parallel to the radiator

• Four fans will blow the Zenith Radiator, having their axis parallel to the 4 zenith radiator quadrants

Page 6: Thermal control GSE at KSC

AMS Ground Safety Review II Sept. 2008 – KSC 6

AMS 02 –Thermal Control

System Design

Fans on zenith radiators

Zenith Radiator

Tracker Radiator

WAKE Radiator

Tracker Radiator

RAM Radiator

Main Radiator

WakeMain Radiator

Ram

RamWake

Page 7: Thermal control GSE at KSC

AMS Ground Safety Review II Sept. 2008 – KSC 7

AMS 02 –Thermal Control

System Design

Zenith Radiator

Tracker Radiator

WAKE Radiator

Tracker Radiator

RAM Radiator

Main Radiator

WakeMain Radiator

Ram

RamWake

Fans on RAM radiator

Page 8: Thermal control GSE at KSC

AMS Ground Safety Review II Sept. 2008 – KSC 8

AMS 02 –Thermal Control

System Design

Zenith Radiator

Tracker Radiator

WAKE Radiator

Tracker Radiator

RAM Radiator

Main Radiator

WakeMain Radiator

Ram

RamWake

Fans on WAKE radiator

Page 9: Thermal control GSE at KSC

AMS Ground Safety Review II Sept. 2008 – KSC 9

AMS 02 –Thermal Control

System Design

Page 10: Thermal control GSE at KSC

AMS Ground Safety Review II Sept. 2008 – KSC 10

AMS 02 –Thermal Control

System Design

Page 11: Thermal control GSE at KSC

AMS Ground Safety Review II Sept. 2008 – KSC 11

AMS 02 –Thermal Control

System Design

Type B Fans

• Quantity 3

• Diameter >0.18 m

• Flow Rate 740 m3/h

• Unit power (reference value) 50 W

• Voltage 110 V

• AC supply Frequency 60 Hz

Page 12: Thermal control GSE at KSC

AMS Ground Safety Review II Sept. 2008 – KSC 12

AMS 02 –Thermal Control

System Design

Type B fans usage

• One fan is dedicated to the PDS, and it shall work at the same time of the Wake radiator fans.

• The other two fans shall blow air to the CAB on two of its faces (wake and starboard).

Page 13: Thermal control GSE at KSC

AMS Ground Safety Review II Sept. 2008 – KSC 13

AMS 02 –Thermal Control

System Design

Type B fans location

Zenith Radiator

Tracker Radiator

WAKE Radiator

Tracker Radiator

RAM Radiator

Main Radiator

WakeMain Radiator

Ram

RamWake

Page 14: Thermal control GSE at KSC

AMS Ground Safety Review II Sept. 2008 – KSC 14

AMS 02 –Thermal Control

System Design

Quality stamp on COTS

• All fans will be commercial off the shelf (COTS) and have the European “CE” quality symbol on it.

• The supplier of the fans is TBD.