Biomass Technology Research Center (BTRC), National Institute of Advanced Industrial Science and Technology (AIST), Japan Tomohisa MIYAZAWA, Kotetsu MATSUNAGA, Toshiaki HANAOKA, Nobuhisa TANABE, Shinji FUJIMOTO, Tomoaki MINOWA, Satoshi HIRATA, Kinya SAKANISHI 7th Asian DME Conference ,Niigata, Nov.17 2011 The synthesis of bio dimethyl ether (DME) & process estimation on economy
18
Embed
The synthesis of bio dimethyl ether (DME) & process estimation on
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Biomass Technology Research Center (BTRC),
National Institute of Advanced Industrial
Science and Technology (AIST), Japan
Tomohisa MIYAZAWA, Kotetsu MATSUNAGA,
Toshiaki HANAOKA, Nobuhisa TANABE,
Shinji FUJIMOTO, Tomoaki MINOWA,
Satoshi HIRATA, Kinya SAKANISHI
7th Asian DME Conference ,Niigata, Nov.17 2011
The synthesis of bio dimethyl ether (DME) & process estimation on economy
The synthesis of bio dimethyl ether (DME) & process estimation on economy
7th Asian DME Conference
Gasification &Bio-DME synthesis Gasification
Gas cleaning Compression
We have carried out consecutive plant-operation from biomass to DME on a bench-scale
DME synthesis Biomass
Bio-DME
Process estimation on economy based on the plant operation data
Gas composition(Gasification gas in the bench-plant): CO H2 CH4 CO2 N2 COS, H2S 31.2% 25.6% 2.7% 0.4% 40.1% <5ppb
Reaction condition (DME synthesis)
Results of DME synthesis from gasification gas
Effect of W/F on the DME synthesis
Feed gas flow rate [L/min]
1.5 1.0 0.5 0.2
T=250 oC
P=0.98 MPa
● DME yield increased with an increase in W/F. ● 3CO + 3H2 ⇋ CH3OCH3 + CO2 has been proceeding.
DME
MeOH
● Methanol yield was less than 1/100 of DME. ● Amount of DME(mol)
≒3×Decrease of CO or H2
Ethanol
refrigerant
Ethanol refrigerant
+ activated carbon
Boiling point of the DME : -24oC
Ethanol refrigerant temp.: -35oC
Dry ice refrigerant temp. : -80oC
DME concentration & recovery rate after trap
● Just only cooling is not enough to recover DME. ● Combination of cooling & adsorption to activated carbon can capture almost all DME in the outlet gas.
DME recovery methods
Long time reaction and DME recovery
Results of DME production for long time
● We have succeeded in the stable continuous synthesis of DME over 200 h. ● Recovering 100 g of liquefied bio-DME.
W/F=75.8 kg h/m3
T=230oc P=0.98 MPa
Succeed in recovery
of liquefied bio-DME
0
20
40
60
80
100
0
5
10
15
20
25
30
0 100 200 300 400 500 600
CO
convers
ion [
%]
Pro
duct gas c
om
positio
n [
vol%
]
Time on stream [h]
CO
H2
CO2
DME
CO conv.
Results of DME production using upgraded gas
Upgrading of gasification & DME synthesis
W/F=75.8 kg h/m3
T=230oc P=0.98 MPa
Gas composition/%
CO H2 CH4 CO2 N2
48.9 39.8 4.3 2.6 4.1
Produced gas composition
in the high O2 content
gasification.
● Syngas content in the feed gas could be increased(57→89%). ● DME yield also could be increased.
Bio-DME vehicle running demonstration
Finally we have operated DME synthesis total 1000 h
& succeeded in the recovery of 1.1 kg bio-DME.
● DME vehicle promotion committee, Japan(DMEVPC) have demonstrated bio-DME vehicle running test on May 18, 2010. The mixture of our synthesized bio-DME with DME produced from natural gas at Niigata DME plant was used as DME fuel.
Process estimation on economy based on the plant operation data
Gasifier
Gas cleaning
CO2 removal
DME synthesis
Biomass Process estimation on economy
Process simulation Oxygen-
enriched air
Compre
-ssion
Bio-DME
Based on the plant operation data, we studied effect of pressure
of DME synthesis in biomass to dimethyl ether (DME) process
on the economy.
5 MPa or 0.98 MPa
unit Base cost Scale
factor Base scale
Overall installation
factor
Maximum
size
Compressor 12.9 0.85 13.2 MWe 1.86 -
Slurry reactor 36.5 0.72 362 m3 1 365 m3
Costs of system components in M€2002*
* ) Hamelinck Et al, ENERGY, 29, 1743-1771 (2004)
0
0.2
0.4
0.6
0.8
1
P=5.0MPa P=0.98MPa
Rel
ativ
e un
it c
ost
of s
yste
m c
ompo
nent
[-]
Slurry
ReactorCompressor
0
0.2
0.4
0.6
0.8
1
P=5.0MPa P=0.98MPa
Rel
ativ
e po
wer
con
sum
ptio
n [-
]
Effect of pressure on the process costs
Relative cost of compressor for 0.98 MPa is about 60% of those for 5.0 MPa
and the cost of slurry reactor for 0.98 MPa is about 20% of 5.0 MPa.
Cost dependence on the
components size
C1=C0×(S1/S0)R
1. We succeeded in the continuous synthesis of
DME from biomass derived gasification gas at
low pressure below 1MPa and recovery of about
1.1 kg of liquefied bio-DME.
2. It was found that DME synthesis at low pressure