LaBella Powered by partnership. AUGUST 2021 2192683.01 CONSTRUCTION EDGEWATER ART HOUSE THE RESOURCE CENTER 712 W. EIGHTH STREET JAMESTOWN, NY 14701 EDGEWATER ART HOUSE 712 W. EIGHTH STREET JAMESTOWN, NY 14701 THE RESOURCE CENTER LABELLA PROJECT NUMBER: 2192683.01 ISSUED FOR : CONSTRUCTION PROJECT LOCATION GENERAL G001 COVER SHEET G002 CODE COMPLIANCE AND LIFE SAFETY PLANS G003 NOTES, SYMBOLS AND ABBREVIATIONS CIVIL C101 SITE PLAN AND DETAILS ARCHITECTURAL A001 DEMOLITION PLAN A101 FLOOR PLAN A102 ROOF PLAN AND DETAILS A110 REFLECTED CEILING PLAN A201 EXTERIOR ELEVATIONS A401 ENLARGED PLANS, INTERIOR ELEVATIONS AND DETAILS A501 STAIR PLAN, SECTIONS, AND DETAILS A601 SCHEDULES AND DETAILS FIRE PROTECTION F001 FIRE PROTECTION LEGEND SHEET F101 FIRST FLOOR FIRE PROTECTION PLAN MECHANICAL M001 MECHANICAL LEGEND SHEET M101 FIRST FLOOR DUCTWORK PLAN AND SCHEDULES M501 MECHANICAL DETAILS M601 MECHANICAL SPECIFICATIONS ELECTRICAL E001 ELECTRICAL NOTES, SYMBOL LEGEND, & ABBREVIATIONS E050 ELECTRICAL SPECIFICATIONS E101 LEVEL 01 - REMOVAL, LIGHTING, POWER & SYSTEMS PLAN E600 ELECTRICAL SCHEDULES PLUMBING P001 PLUMBING LEGEND SHEET P101 PLUMBING PLAN DRAWING INDEX
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
La
Be
lla
Po
we
red
by
pa
rtn
ers
hip
.
AU
GU
ST 2
02
12
19
26
83
.01
CO
NS
TR
UC
TIO
NED
GEW
ATER
AR
T H
OU
SE
TH
E R
ES
OU
RC
E C
EN
TER
71
2 W
. EIG
HTH
STR
EET
JAM
ES
TO
WN
, N
Y 1
47
01
EDGEWATER ART HOUSE
712 W. EIGHTH STREET
JAMESTOWN, NY 14701
THE RESOURCE CENTER
LABELLA PROJECT NUMBER: 2192683.01
ISSUED FOR : CONSTRUCTION
PROJECT LOCATIONGENERAL
G001 COVER SHEET
G002 CODE COMPLIANCE AND LIFE SAFETY PLANS
G003 NOTES, SYMBOLS AND ABBREVIATIONS
CIVIL
C101 SITE PLAN AND DETAILS
ARCHITECTURAL
A001 DEMOLITION PLAN
A101 FLOOR PLAN
A102 ROOF PLAN AND DETAILS
A110 REFLECTED CEILING PLAN
A201 EXTERIOR ELEVATIONS
A401 ENLARGED PLANS, INTERIOR ELEVATIONS AND DETAILS
A501 STAIR PLAN, SECTIONS, AND DETAILS
A601 SCHEDULES AND DETAILS
FIRE PROTECTION
F001 FIRE PROTECTION LEGEND SHEET
F101 FIRST FLOOR FIRE PROTECTION PLAN
MECHANICAL
M001 MECHANICAL LEGEND SHEET
M101 FIRST FLOOR DUCTWORK PLAN AND SCHEDULES
M501 MECHANICAL DETAILS
M601 MECHANICAL SPECIFICATIONS
ELECTRICAL
E001 ELECTRICAL NOTES, SYMBOL LEGEND, & ABBREVIATIONS
E050 ELECTRICAL SPECIFICATIONS
E101 LEVEL 01 - REMOVAL, LIGHTING, POWER & SYSTEMS PLAN
E600 ELECTRICAL SCHEDULES
PLUMBING
P001 PLUMBING LEGEND SHEET
P101 PLUMBING PLAN
DRAWING INDEX
MATERIAL SYMBOLS
CONCRETE MASONRY UNITS(CMU)
CONCRETE
BRICK
CEMENT, SAND, GROUT, PLASTER, OR GYPSUM WALL BOARD
FB: Face BrickFD: Floor drainFDC: Fire Department ConnectionFDN: FoundationFDTN: FoundationFE: Fire ExtinguisherFEC: Fire Extinguisher CabinetFFE: Finished Floor ElevationFF&E: Fixtures, Furnishings & EquipmentFFL: Finished Floor LineFGL: FiberglassFHC: Fire Hose CabinetFIN: Finish, finishedFIXT: FixtureFL: FloorFLR: FloorFO: Finished OpeningFOF: Face of FinishFOS: Face of StudsFP: FireproofFRT: Fire RetardantFT: Foot, Feet,FTG: Footing, FittingFURN: Furnish, FurnitureFURR: Furring
N: North, NitrogenNAP: NapkinNAT: NaturalNATL: NaturalNB: "Nota Bene" Latin phrase for "Take Special Note"NC: Normally Closed, Noise CriteriaNEC: National Electrical CodeNEUT: NeutralNF: Near FaceNFWH: Non-freeze Wall HydrantNI: NickelNIC: Not In ContractNK: NeckNMT: Non-MetallicNO: Number, Normally OpenNOM: NominalNR: Noise ReductionNRC: Noise Reduction CoefficientNTS: Not To Scale
OB: ObscureOBS: ObscureOC: On CenterOD: Outside DiameterOF: Outside FaceOFF: OfficeOH: OverheadOHD: Overhead DoorOPNG: OpeningOPP: OppositeOPP H: Opposite Hand
CONSTRUCTION SHALL CONFORM TO THE “NEW YORK STATE UNIFORM FIRE PROTECTION AND BUILDING CODE”, LATEST REVISION, THE NEW YORK STATE ENERGY CODE AND ANY OTHER CODES GOVERNED BY THE JURISDICTION IN WHICH THE PROJECT IS BEING CONSTRUCTED.
CONSTRUCTION SHALL COMPLY WITH ALL LOCAL, STATE AND FEDERAL CODES AND REGULATIONS.
ALL DRAWINGS ARE GRAPHIC REPRESENTATIONS OF APPROXIMATE LOCATIONS OF NEW MATERIALS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY ALL CONDITIONS PRIOR TO COMMENCEMENT OF WORK.
CONTRACTORS ARE RESPONSIBLE FOR ALL MATERIALS, CONSTRUCTION METHODS AND CRAFTSMANSHIP.
CONTRACTORS ARE TO VERIFY ALL EXISTING CONDITIONS, REQUIREMENTS, NOTES, CODES AND DIMENSIONS, PRIOR TO THE START OF CONSTRUCTION AND SHALL NOTIFY THE ARCHITECT IF CONDITIONS VARY FROM THOSE SHOWN ON THE DOCUMENTS.
CONTRACTORS ARE TO PROVIDE ADEQUATE SUPPORT OF EXISTING FOUNDATION WALLS, LOAD BEARING WALLS AND PARTITIONS DURING DEMOLITION AND CONSTRUCTION.
THOROUGHLY COORDINATE WORK WITH OTHER TRADES AND DETERMINE THE EXACT ROUTE AND LOCATION OF UTILITIES, MATERIALS AND EQUIPMENT BEFORE FABRICATION AND INSTALLATION.
WHEN EXISTING CONSTRUCTION IS REMOVED, DISTURBED, DAMAGED, REPLACED OR RENOVATED IN ANY WAY, CONTRACTORS SHALL PROVIDE PATCHING, PAINTING AND MATERIALS OF SAME TYPE AND QUALITY AS TO MATCH ADJACENT EXISTING SURFACES, UNLESS OTHERWISE NOTED.
CONTRACTORS PROVIDE ALL BLOCKING, FURRING AND SHIMMING FOR INSTALLATION AND COMPLETION OF WORK.
ALL NEW WORK SHALL BE PLUMB, LEVEL AND SQUARE. SCRIBE AND MAKE FIT ALL NEW TO EXISTING.
CONTRACTORS VERIFY ALL DIMENSIONS BEFORE ORDERING MATERIAL OR DOING WORK. NO EXTRA COMPENSATION OR CHARGES WILL BE ACCEPTED DUE TO DIFFERENCES BETWEEN THE ACTUAL MEASUREMENTS AND MEASUREMENTS INDICATED ON THE DRAWINGS.
ALL DETAILS ARE SUBJECT TO CHANGE DUE TO EXISTING FIELD CONDITIONS. CONTRACTOR MUST NOTIFY ARCHITECT OF SAME.
NO SITE VISITS WILL BE MADE BY THE ARCHITECT. THE CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR CHANGES TO THESE DRAWINGS AND COMPLETION OF COMPLIANT WORK.
ARCHITECT TO COORDINATE ALL DOOR HARDWARE, TRIM AND FINISHES TO MEET INTENT AND COMPLIANCE.
THESE DRAWINGS DO NOT PURPORT TO SHOW ALL ITEMS AND PROCEDURES REQUIRED FOR A COMPLETE INSTALLATION. THE INTENT IS TO INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF THE GENERAL ARCHITECTURAL DESIGN CONCEPT, THE LOCATION/DIMENSIONS OF THE CONSTRUCTION AND MAJOR ELEMENTS OF CONSTRUCTION.
CONTRACTORS ARE RESPONSIBLE FOR OBTAINING AND PAYING FOR ALL PERMITS ASSOCIATED WITH THE WORK OF THEIR CONTRACT.
ITEMS NOTED AS 'BY OWNER” ARE TO BE FURNISHED AND INSTALLED BY THE OWNER OR THE OWNER'S VENDOR.
GENERAL CONSTRUCTION NOTES:1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
GENERAL REMOVAL NOTES:DASHED LINES INDICATE ITEMS TO BE REMOVED.
ELEMENTS TO REMAIN IN PLACE SHALL BE PROTECTED FROM DAMAGE, DUST AND DEBRIS.
DUST CONTROL SHALL BE THE FULL RESPONSIBILITY OF THE CONTRACTOR. CONTRACTOR SHALL PERFORM CLEAN UP OF ALL REFUSE, RUBBISH, SCRAP MATERIALS AND DEBRIS CAUSED BY THE WORK ON A DAILY BASIS. CLEANING OF AREA SURROUNDING THE WORK AREA WHERE CONSTRUCTION DEBRIS OR DUST ACCUMULATES WILL BE THE RESPONSIBILITY OF THE CONTRACTOR.
REFER TO CIVIL, STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND FIRE PROTECTIONS DRAWINGS FOR DEMOLITION OF ADDITIONAL ITEMS. REFER TO ABATEMENT DRAWINGS FOR HAZARDOUS MATERIAL DEMOLITION ITEMS.
CONTRACTOR TO MAINTAIN WATER TIGHT INTEGRITY OF BUILDING AT ALL TIMES.
EXISTING CONDITIONS ARE TAKEN FROM FIELD OBSERVATIONS AND PRIOR CONSTRUCTION DOCUMENTS WHEN AVAILABLE AND ARE NOT GUARANTEED. CONTRACTORS ARE RESPONSIBLE FOR EXAMINING THE BUILDING AND VERIFYING EXISTING CONDITIONS AND ARE TO CONTACT THE OWNER REPRESENTATIVE REGARDING ANY DISCREPANCIES.
DEMOLITION WORK SHALL INCLUDE REMOVAL OF ALL ITEMS INDICATED TO BE REMOVED AND/OR SALVAGED, AND LEGAL DISPOSAL OF ITEMS NOT INTENDED FOR SALVAGE. WORK SHALL ALSO INCLUDE REMOVAL OF ALL MINOR SUPPORTS, BRACKETS, FASTENERS, CONDUITS, PIPING, AND SIMILAR ITEMS WHICH ARE NOT INDICATED TO REMAIN.
ALL FLOOR AND WALL CONDITIONS WHICH ARE TO RECEIVE NEW CONSTRUCTION ARE TO BE DEMOLISHED AS INDICATED AND PROPERLY PREPPED TO RECEIVE NEW FINISHES, U.N.O.
ALL FLOOR, WALL, AND CEILING CONDITIONS THAT ARE DISTURBED BY DEMOLITION ARE TO BE PATCHED, REPAIRED AND/OR PAINTED, WITH SIMILAR MATERIALS AND COLORS. REFER TO NEW WORK FLOOR PLANS, REFLECTED CEILING PLANS, AND FINISH SCHEDULE.
AT WALL REMOVAL FOR MECHANICAL PENETRATIONS, OPENING TO BE APPROXIMATELY 6" LARGER THAN DUCT SIZE ON ALL SIDES. COORDINATE WITH MECHANICAL DRAWINGS.
ALL EMBOSSED DECORATIVE DOOR KNOBS TO BE SALVAGED AND TURNED OVER TO OWNER.
FOR ADDITIONAL REMOVAL INFORMATION REFER TO SECTIONS AND DETAILS.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
UNLESS OTHERWISE NOTED, ALL MASONRY DIMENSIONING IS NOMINAL TO FACE OF MASONRY, ALL NON-MASONRY DIMENSIONING IS TO FACE OF PARTITIONS OR WALLS AND ALL CONCRETE DIMENSIONING IS FACE TO FACE OF WALL.
ALL DIMENSIONS ARE TO THE OUTSIDE FINISH SURFACE OF WALLS OR TO COLUMN CENTERLINES.
ALL DIMENSIONS ARE FINISHES DIMENSIONS FROM FINISH FACE OF GYPSUM BOARD OR SCHEDULED WALL FINISH UNLESS OTHERWISE NOTED.
PROVIDE CONCEALED BLOCKING IN ALL STUD PARTITIONS AND WALLS BEHIND SURFACE FOR SEMI-RECESSED, FULLY RECESSED OR SURFACE MOUNTED ACCESSORIES AND MILLWORK.
DIMENSIONS NOTED AS “CLEAR” ARE TO FINISHED SURFACE AND ARE CRITICAL FOR ACCESSIBILITY REQUIREMENTS OR BUILT-IN FURNISHINGS.
CONTRACTOR SHALL FIELD VERIFY FINISHED DIMENSIONS AND CLEARANCES IN SPACES INDICATED TO RECEIVE BUILT-IN FURNISHINGS OR CASEWORK PRIOR TO FABRICATION.
ALL VERTICAL CONCRETE SURFACES WHICH WILL BE EXPOSED TO VIEW UPON COMPLETION OF WORK SHALL RECEIVE A SMOOTH RUBBED FINISH.
ALL ENDS OF MASONRY WALLS THAT WILL BE EXPOSED TO VIEW UPON COMPLETION OF WORK SHALL BE PLAIN END UNITS.
FINISHED DOOR OPENINGS SHALL BE NOMINAL 6” FROM FINISHED CORNER OF ROOM EXCEPT WHERE DIMENSIONED OTHERWISE.
SEALANT SHALL BE PROVIDED AT THE INTERIOR AND EXTERIOR PERIMETER OF ALL WINDOWS, DOOR FRAMES, LOUVERS OR OTHER ITEMS INSERTED IN AN EXTERIOR WALL.
SUSPENDED GRID CEILINGS SHALL BE ARRANGED SO THAT A GRID IS SPACED EQUALLY FROM EACH MOST REMOTE WALL, IN EACH DIRECTION, WITH NO TILES LESS THAN 6” UNLESS OTHERWISE INDICATED.
WOOD USED FOR BLOCKING OR OTHER PURPOSES ON OR ABOVE THE ROOF DECK, WITHIN 2'-0” OF GRADE AND IN OTHER LOCATIONS OUTSIDE THE BUILDING ENVELOPE WHERE EXPOSED TO THE WEATHER SHALL BE PRESSURE TREATED LUMBER OR PLYWOOD.
INSTALL ALL WORK AS INDICATED AND VERIFY EXACT LOCATION AND ELEVATIONS ON THE JOB.
DO NOT SCALE DRAWINGS. REFER TO DIMENSIONS AND SPECIFIED MATERIALS. CONTACT THE ARCHITECT IF ADDITIONAL DIMENSIONS ARE REQUIRED.
COORDINATE ALL DOOR HARDWARE, TRIM AND FINISHES TO MEET INTENT AND COMPLIANCE.
FIRST FLOOR LEVEL DATUM ELEVATION (0'-0") IS EQUAL TO ACTUALELEVATION (XX'-XX"). ARCHITECTURAL ELEVATIONS U.O.N. ARE TAKEN FROM FINISHED FIRST FLOOR LEVEL DATUM ELEVATION (0'-0").
INTERIOR WALL AND CEILING FINISH MINIMAL REQUIREMENTS (FINISH CLASSIFICATIONS IN ACCORDANCE WITH ASTM E84) ARE AS FOLLOWS:
VERTICAL EXITS AND EXIT PASSAGEWAYS - CLASS BEXIT ACCESS CORRIDORS AND OTHER EXIT WAYS - CLASS CROOMS AND ENCLOSED SPACES - CLASS C
TRUSS IDENTIFICATION SIGNS SHALL BE PROVIDED IN ACCORDANCE WITH TITLE 19 NYCRR PART 1264 AND APPENDIX H OF THE FIRE CODE OF NEW YORK STATE 2010. TRUSS IDENTIFICATION SIGNS SHALL BE LOCATED AT BUILDING ENTRANCE DOORS, EXTERIOR DISCHARGE DOORS AND FIRE DEPARTMENT HOSE CONNECTIONS.
A. ATTACH SIGN TO FACE OF DOOR, OR ATTACHED TO A SIDELIGHT OR FACE OF THE BUILDING NOT MORE THAN 12 INCHES HORIZONTALLY FROM THE LATCH SIDE OF THE DOOR JAMB, AND NOT LESS THAN 42 INCHES NOR MORE THAN 60 INCHES ABOVE THE ADJOINING WALKING SURFACES.
B. ATTACH SIGN AT EACH END OF A ROW OF DOORS AT A MAXIMUM HORIZONTAL DISTANCE OF 12 FEET BETWEEN SIGNS, AND NOT LESS THAN 42 INCHES NOR MORE THAN 60 INCHES ABOVE THE ADJOINING WALKING SURFACE.
C. AT FIRE DEPARTMENT HOSE CONNECTIONS ATTACH TO THE FACE OF BUILDING, NOT MORE THAN 12 INCHES HORIZONTALLY FROM THE CENTER LINE OF THE FIRE DEPARTMENT HOSE CONNECTION, AND NOT LESS THAN 42 INCHES NOR MORE THAN 60 INCHES ABOVE THE ADJOINING WALKING SURFACE.
D. SIGNS IDENTIFYING THE EXISTENCE OF TRUSS CONSTRUCTION SHALL CONSIST OF A CIRCLE 6 INCHES IN DIAMETER, WITH A STROKE WIDTH OF 1/2 INCH. THE SIGN BACKGROUND SHALL BE REFLECTIVE WHITE IN COLOR. THE CIRCLE AND CONTENTS SHALL BE REFLECTIVE RED IN COLOR, CONFORMING TO PANTONE MATCHING SYSTEM (PMS) # 187. WHERE A SIGN IS DIRECTLY APPLIED TO A DOOR OR SIDELIGHT, IT MAY BE A PERMANENT STICKER OR DECAL. SIGNS NOT DIRECTLY APPLIED TO DOORS OR SIDELIGHTS SHALL BE STURDY, NON-FADING, WEATHER RESISTANT MATERIAL.
F. SIGNS SHALL CONTAIN THE ROMAN ALPHANUMERIC DESIGNATION OF THE CONSTRUCTION TYPE OF THE BUILDING, IN ACCORDANCE WITH THE PROVISIONS FOR THE CLASSIFICATION OF TYPES SET FORTH IN SECTION 602 OF THE BUILDING CODE OF NEW YORK STATE 2010, AND AN ALPHABETIC DESIGNATION FOR THE STRUCTURAL COMPONENTS THAT ARE OF TRUSS CONSTRUCTION AS FOLLOWS:
"F" SHALL MEAN FLOOR FRAMING, INCLUDING GIRDERS AND BEAMS
"R" SHALL MEAN ROOF FRAMING
"FR" SHALL MEAN FLOOR AND ROOF FRAMING
G. THE CONSTRUCTION TYPE DESIGNATION SHALL BE PLACED AT TWELVE O'CLOCK POSITION OVER THE STRUCTURAL COMPONENT DESIGNATION, WHICH SHALL BE PLACED AT THE SIX O'CLOCK POSITION. REFER TO FOLLOWING SYMBOL FOR THIS BUILDING:
GENERAL ARCHITECTURAL NOTES
IIBR
ROMAN ALPHANUMERIC DESIGNATION OF CONSTRUCTION
ALPHABETIC DESIGNATION FOR THE STRUCTURAL COMPONENTS THAT ARE TRUSS CONSTRUCTION
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
OVERHEAD
VISIBLE ITEMS
BREAK LINE
HIDDEN OR NOT IN CONTRACT
CENTER LINE OR COLUMN GRID
C.M.U. WALL / PARTITION - SEE PARTITION TYPES
EXISTING WALL CONSTRUCTION
METAL STUD PARTITION - SEE PARTITION TYPES
WALL/ PARTITION DESIGNATIONS
BRICK FACE
LINE TYPES
500 East Sixth StreetJamestown, NY 14701716-483-3153
labellapc.com
DRAWING NAME:
It is a violation of New York Education Law Article 145 Sec.7209, for any person, unless
acting under the direction of a licensed architect, professional engineer, or land
surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or
land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the
item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the
SITE PLAN KEYNOTESS1 STAMPED CONC. TERRACE TO BE INSTALLED, SEE (DETAIL 3/C101)
S2 BOLLARD W/ ILLUMINATED CAP TO BE INSTALLED (SEE DETAIL 2/C101)(SEE ELEC. DWGS.)
S3 NEW MULCH PLANTING BED AND PLANTINGS (LANDSCAPING NOT IN CONTRACT, SEESECTION 012100 ALLOWANCES OF THE PROJECT MANUAL)
S4 NEW SIGNAGE ON MASONRY PIER TO BE INSTALLED (SEE DETAIL 4/C101)(REFER TOSECTION 01-21-00 "ALLOWANCES OF THE PROJECT MANUAL" FOR MORE INFORMATION -ALLOWANCE #4)
S5 CONTROL JOINT
S6 EXPANSION JOINT
SCALE: 1" = 1'-0"C101
2 BOLLARD DETAIL
SCALE: 1" = 1'-0"C101
3 PAVING DETAIL
SCALE: 3/4" = 1'-0"C101
4 NEW SIGNAGE PIER
Revisions
NO: DATE: DESCRIPTION:
D2
D5
D8
D4 D4
D3D4
D6
D6
D6
D6
D7
16' - 8" +/-
EXIST. ELECTRICALPANEL TO REMAIN
EXIST. STL. COLTO REMAIN
EXIST. STL. COLTO REMAIN
EXIST. STL. COLTO REMAIN
1' - 5 1/4"
3' - 4"
48
' - 6
" +
/-
EXIST. COLUMNTO REMAIN
1H
RE
16
' - 2
1/4
"1
6' -
1"
(EXI
ST.
PLY
WO
OD
)1
1' -
11
"
13
' - 1
0 1
/2"
(EXI
ST.
ELE
C E
QU
IP.)
1' - 2 1/2"
ALIGN.
EDGE OF EXIST.ASPHALT PAVEMENTTO REMAIN
D1
D3
D1D10D10
D10
D10
D9D9
D9
D9
EDGE OF EXIST.ASPHALT PAVEMENTTO REMAIN
10
' - 1
" +
/-
ALIGN.
500 East Sixth StreetJamestown, NY 14701716-483-3153
labellapc.com
DRAWING NAME:
It is a violation of New York Education Law Article 145 Sec.7209, for any person, unless
acting under the direction of a licensed architect, professional engineer, or land
surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or
land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the
item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the
DEMOLITION KEY NOTESD1 REMOVE EXIST. ALUM. GUTTER AND DOWNSPOUTS.
D2 PORTION OF EXISTING CMU WALL TO BE REMOVED AS REQ'D FOR NEW WINDOW FRAME.
D3 EXISTING DOOR, FRAME, AND HARDWARE TO BE REMOVED.
D4 EXISTING WINDOW TO BE REMOVED.
D5 EXISTING OVERHEAD DOOR, TRACK, AND ASSOCIATED BLOCKING TO BE REMOVED.
D6 EXISTING CONC. BOLLARD AND FOOTING TO BE REMOVED
D7 PORTION OF EXIST. ASPHALT PAVING TO BE REMOVED.
D8 PORTION OF EXIST. EXTERIOR WALL TO BE REMOVED AS' REQ. FOR NEW DOOR OPENING.
D9 REMOVE EXIST. ALUM. FASCIA AT NORTH AND EAST WALLS.
D10 REMOVE EXISTING EIFS BANDS, APPROXIMATELY 8" WIDE X 1 1/2" THICK. (BASE EIFS, APPROX. 1 1/2"THICK, IS TO REMAIN EXCEPT FOR WHERE ITS PARTIAL REMOVALS ARE INDICATED.
N
NOTE:
REFER TO MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION REGARDING DEMOLITION AND REMOVALS
Revisions
NO: DATE: DESCRIPTION:
UP
196 SF
KILN05
24 SF
STORAGE05A
90 SF
PASSAGE04
506 SF
SHOP/DISPLAY01
637 SF
ART CLASSROOM02
20 SF
JANITOR01B
64 SF
ELEC.01C
60 SF
TOILET03
29 SF
STORAGE01A
EXIST. ELECTRICALPANEL TO REMAIN
A1
W1 W1
4
2
4
1
1
1
1
2
5
A501
4
3
A501
___________
01-1
01-4
03-1
01-3
01-2
02-3
05-2
02-1
02-2
W2
A2
A2
4' -
6"
+/-
AS
REQ
'D.
AT
EXIS
T. P
AN
EL
14
' - 4
" +
/- (
V.I.
F.)
8' -
4 1
/2"
7' - 4 1/2" +/- 5' - 8" +/- 4' - 7" 5' - 0"
4' - 10"
5' -
0"
8' -
3 5
/8"
+/-
A1
A2A2 A2
A3
A3
A3
7' - 4"
A2
2
4
4' - 5 1/2" +/-
8"
3
1
A501
1
EXIST
LOBBY / CORRIDOR
4
4
4
23' - 1" 3' -
2"
5' -
0"
1' -
3"
2' - 8 1/8" +/-
5
A501
___________
4' -
0"
3' - 0"
04-1
A15
A6
A5
A6
A18
A19
5"
A4
A8
A9
A9
A17
A401
1
A5
A7
A21
A20
A401
4
5
A22
A10
A201 1
A201
2
A2
05-1
A23
A31
A24
7"
3' -
11
1/4
"
A25
1' - 2"
A30
A27A27
A27A27
A27A27
A27A27
A29
3
FEC
-1
A28
2
THE WALL TYPES THAT CONTAIN UL DESIGN NUMBERS OR GYPSUM ASSOCIATION (GA) DESIGN NUMBERS AND STC RQTINGS THAT FOLLOW THE WALL DESCRIPTION, MUST BE FULLY ADHERED TO, THIS INCLUDES ALL THROUGH-WALL PENETRATIONS.
ALL FIRE-RATED PARTITIONS SHALL EXTEND TO UNDERSIDE OF DECK AND SHALL BE SEALED SMOKE-TIGHT, INCLUDING NON-COMBUSTIBLE FILLER AT JOINTS.
NON-RATED STUD PARTITIONS W/ SOUND ATTENTUATION INSULATION SHALL FULL HEIGHT TO UNDERSIDE OF JOISTS INCLUDING GYP. BD. BOTH SIDES.
PATCH & LEVEL EXISTING/NEW SUBSTRATE TO PROVIDE SMOOTH SURFACE ACCEPTABLE FOR GYP. BD. OR CERAMIC TILE.
REFER TO ROOM FINISH SCHEDULE, FLOOR PLANS, WALL SECTIONS, INTERIOR ELEVATIONS & SPECIFICATIONS FOR ALL FINISHES OR OTHER VARIATIONS IN MATERIALS.
REFER TO MECH./ELEC./PLUMB. DWGS. FOR ADDITIONAL INFO. AND COORDINATION OF EQUIPMENT AND INSTALLATIONS.
PROVIDE BLOCKING WITHIN WALLS FOR CABINETRY, TOILET ROOM ACCESSORIES AND ALL ASSOCCIATED ACCESSORIES.
CEILING PLAN KEY NOTESC1 EXIST. ROOF DECK AND STRUCTURE, INCLUDING BEAMS, RAFTERS, CROSS BRACING, ETC. TO BE
PAINTED; COLOR SELECTED BY ARCHITECT. PREPARATION TO INCLUDE REMOVAL OF ABANDONEDPIPING, CONDUIT, NAILS, STAPLES, HANGERS, STRAPS, ETC. THOROUGHLY WASH AND PRIME COAT.APPLY 2 FINISH COATS.
C2 GYP. BD. SOFFIT TO BE INSTALLED, PAINT. (SEE DETAIL 1/A110)
C3 ACOUSTIC TILE CEILING GRID AND TILES TO BE INSTALLED.
C4 KILN EXHAUST VENT TO BE INSTALLED (SEE MECH. DWGS.)
C5 DUCTWORK TO BE INSTALLED, TYP. (SEE MECH. DWGS.)
C6 PENDANT LIGHT FIXTURE TO BE INSTALLED, TYP. (SEE ELEC. DWGS.)
C7 RECESSED LIGHT FIXTURE TO BE INSTALLED, TYP. (SEE ELEC. DWGS.)
C8 EMERGENCY LIGHT FIXTURE TO BE INSTALLED (SEE ELEC. DWGS.)
C9 NEW CANOPY ABOVE, TYP. (SEE ROOF PLAN)
C10 WALL MOUNTED EXTERIOR LIGHT FIXTURE, TYP. (SEE ELEC. DWGS.)
C11 OVERHEAD DOOR TRACK BY OVHD MANUFACTURER.
C12 WALL MOUNTED EXIT SIGNAGE TO BE INSTALLED, TYP. (SEE ELEC. DWGS.)
C13 EXHAUST FAN TO BE INSTALLED (SEE MECH. DWGS.)
SCALE: 1/4" = 1'-0"A110
2 REFLECTED CEILING PLANSCALE: 3/4" = 1'-0"A110
1 DETAIL @ SOFFIT
Revisions
NO: DATE: DESCRIPTION:
1ST FLOOR
0' - 0"
ART HOUSE
-3' - 0" EXISTING STAIRAND LANDING(HIDDEN FOR CLARITY)
EXISTING ROOF CANOPY (HIDDEN)
EXISTING DAY HAB FACILITY
2
A102
___________
E9
E13
E21
E14 E20
E15
E1
E8
E12E12E12E12
E4E4
E10
E16
E3
3' -
7"
E11
E2
E2 E2 17
' - 9
"
9' -
0"
E21E19
E3
1ST FLOOR
0' - 0"
ART HOUSE
-3' - 0"
EXISTING DAY HAB FACILITY
EXIST. SLOPED EPDM ROOF TO REMAIN
E10 E3E16
E17E17
E15
E2
E6
E7
E5
E5
E1
3' -
7"
+/-
E9
E21
E8
E13
E18
EXISTING STAIR AND LANDING(HIDDEN FOR CLARITY)
E2
E2
E3
17
' - 9
"
E7
ALIGN. W/BOTTOM OF WINDOW SILL
500 East Sixth StreetJamestown, NY 14701716-483-3153
labellapc.com
DRAWING NAME:
It is a violation of New York Education Law Article 145 Sec.7209, for any person, unless
acting under the direction of a licensed architect, professional engineer, or land
surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or
land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the
item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the
ELEVATION KEY NOTESE1 KEBONY CHARACTER WOOD CLADDING, 1X8 CHARACTER SQUARE (#2338), INSTALLED
VERTICALLY.
E2 KEBONY CHARACTER WOOD TRIM, 1X4 CHARACTER SQUARE (#1407) AT FACE, WITH1X DEPTH AS REQUIRED FOR HEAD AND JAMB RETURNS.
E3 ADHERED SYNTHETIC STONE VENEER WATER TABLE, "PHEASANT PRO-FIT ALPINELEDGESTONE" BY CULTURED STONE WITH COORDINATING WATERTABLE/SILL BYCULTURED STONE.
E4 THERMALLY BROKEN ALUMINUM STOREFRONT ENTRANCE SYSTEM. "THE RESOURCECENTER" SIGNAGE FOR DOOR TO BE PROVIDED AND INSTALLED UNDER THISCONTRACT. (REFER TO SECTION 012100 ALLOWANCES IN THE PROJECT MANUAL).
E5 PREFIN. ALUM. FASCIA TO BE INSTALLED.
E6 PREFIN. 6" ALUM. BOX GUTTER TO BE INSTALLED, (.040 ALUM.)
E7 PREFIN. 3"X4" ALUM. DOWNSPOUT TO BE INSTALLED, (.040 ALUM.), PROVIDE SPLASHBLOCK.
E8 CORRUGATED METAL CANOPY W/ TUBE STEEL BRACKETS, SEE ROOF PLAN ANDDETAIL.
E9 ADHERED SYNTHEIC STONE VENEER, "PHEASANT PRO-FIT ALPINE LEDGESTONE" BYCULTURED STONE WITH ONE PIECE CAST STONE CAP.
E10 BOLLARD W/ ILLUMINATED CAP TO BE INSTALLED, (SEE DETAIL 11A/501)(SEE ELEC.DWGS.)
E11 WALL MOUNTED EXTERIOR LIGHT FIXTURE, TYP. (SEE ELEC. DWGS.)(REFER TOSECTION 01-21-00 "ALLOWANCES OF THE PROJECT MANUAL" FOR MORE INFORMATION- ALLOWANCE #5)
E12 SECTIONAL GLASS OVERHEAD DOOR TO BE INSTALLED (SEE DOOR SCHEDULE)
E13 METAL BLADE SIGN TO BE INSTALLED, WITH 8" TALL "STENCIL" FONT CUT-OUTLETTERING. (REFER TO SECTION 01-21-00 "ALLOWANCES OF THE PROJECT MANUAL"FOR MORE INFORMATION - ALLOWANCE #4)
E14 10" TALL "STENCIL" FONT METAL BUILDING SIGNAGE ON STANDOFF CLIPS. (REFER TOSECTION 01-21-00 "ALLOWANCES OF THE PROJECT MANUAL" FOR MORE INFORMATION- ALLOWANCE #4)
E15 EMERGENCY LIGHT FIXTURE TO BE INSTALLED (SEE ELEC. DWGS.)
E16 EXISTING GENERATOR TO REMAIN.
E17 THERMALLY BROKEN ALUMINUM STOREFRONT TO BE INSTALLED IN EXIST. MASONRYOPENING WITH OPERABLE CASEMENT WINDOWS WITH SCREENS.
E18 THERMALLY BROKEN ALUMINUM STOREFRONT ENTRANCE SYSTEM (SEE DOORSCHEDULE).
E19 INSTALL WOOD CLADDING TO FIT UNDER AND AROUND EXISTING PORCH STRUCTURE,INCLUDING UNDERSIDE OF ROOF/SOFFIT. INSTALL FLASHING WHERE CLADDING MEETSEXISTING PORCH ROOF. REWORK EXIST. GUTTER AND DOWNSPOUT TO ACCOMMODATEFACADE WORK.
E20 PRE-FIN. ALUMINUM GRAVEL STOP/COPING TO BE INSTALLED.
E21 EXTERIOR SIGNAGE ILLUMINATION / ACCENT LIGHTING (SEE ELEC.)(REFER TO SECTION01-21-00 "ALLOWANCES OF THE PROJECT MANUAL" FOR MORE INFORMATION -ALLOWANCE #4)
Revisions
NO: DATE: DESCRIPTION:
A401
3
2
60 SF
TOILET03
A11
A13
03-1
1' - 6"
CL
5' - 0"
A12
A14
A16
A13
A26
T6
T1T1
T4
T15
T9
T7
T1T1
T9
T4
T5
T2
T15
T5
T6
T3
T10
40
" M
AX.
5
A501
___________
WC 33 30
BC 39 32
WC 15 30
BC 48 32 BC 24 32
WC 33 30
BC 39 32BC 48 32BC 36 32BC 36 32
WC 33 30
2' -
10
"2
' - 2
"2
' - 6
"
T1T1
T11
T11
T13
T17
T4
T16
T20
WC 24 30
BC 27 32
WC 24 30
BC 24 32
WC 33 30
TC 48 90 BC 15 32
2' -
10
"2
' - 2
"2
' - 6
"
T1T1
T15
T19
T14
T18
T12
T11
T13
T8 T4
WC 33 30 WC 33 30
T20
500 East Sixth StreetJamestown, NY 14701716-483-3153
labellapc.com
DRAWING NAME:
It is a violation of New York Education Law Article 145 Sec.7209, for any person, unless
acting under the direction of a licensed architect, professional engineer, or land
surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or
land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the
item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the
FLOOR PLAN KEY NOTESA1 EXIST. WALL TO BE REPAIRED, PATCHED AND PAINT AS REQ.D AT WALL REMOVAL.
A2 EXIST. STL. COLUMN TO REMAIN, SCRAPE, PRIME AND PAINT.
A3 ROLLING BARN DOORS W/ WALL MOUNTED TRACK TO BE INSTALLED. (SEE DOOR SCHEDULE)
A4 NEW RECEPTION DESK.
A5 P.LAM COUNTERTOP W/ BACKSPLASH TO BE INSTALLED (SEE DETAIL 5/A501)
A6 BASE AND WALL MOUNTED CABINETS TO BE INSTALLED (SEE DETAIL 5/A501)
A7 DROP IN SINK BASIN (SEE PLUMB. DWGS.)
A8 THERMALLY BROKEN ALUM. STOREFRONT SYSTEM (SEE DOOR SCHEDULE)
A9 SECTIONAL OVERHEAD DOOR W/ GLAZED PANELS (SEE DOOR SCHEDULE)
A10 POTTERS WHEEL STATION (SEE ELEC. DWGS.)(POTTERY WHEELS N.I.C.)
A11 NEW TOILET (SEE PLUMB. DWGS.)
A12 NEW HANDSINK (SEE PLUMB. DWGS.)
A13 WALL MOUNTED GRAB BARS (PROVIDE IN WALL BLOCKING)
A14 WALL MOUNTED PAPER TOWEL DISPENSER.
A15 LAUNDRY TUB (SEE PLUMB. DWGS.)
A16 24" x 36" U700 SERIES ANGLE FRAME MIRROR BY AJW ARCHITECTURAL PRODUCTS,TEMPERED GLASS.(BOTT. OF REFLECTIVE SURAFACE 40" AFF.)
A17 NEW STAIR AND HANDRAILS TO BE INSTALLED (SEE PLAN 1/A501)
A18 UNDER COUNTER DRAIN PUMP TO BE INSTALLED (SEE PLUMB. DWGS.)
A19 SEWAGE EJECTOR PUMP TO BE INSTALLED (SEE PLUMB. DWGS.)
A20 VENTED KILN TO BE INSTALLED. (KILN N.I.C.)
A21 NON-VENTED KILN TO BE INSTALLED. (KILN N.I.C.)
A22 50" WIDE MOBILE FLOOR DISPLAY PANELS WITH CASTERS (N.I.C.)
A23 FLOOR MOUNTED UTILITY SINK (SEE PLUMB. DWGS.)
A24 P.LAM UNDERSINK PIPE PROTECTION AND KNEE GUARD AS REQ'D. (SEE 1/G003)
A25 COUNTERTOP EYE WASH STATION (SEE PLUMB. DWGS.)
A26 NEW TOILET PAPER DISPENSER.
A27 POLYUREA FLOOR COATING REFINISHING SYSTEM. SEE ROOM FINISH SCHEDULE FOR MOREINFORMATION.
A28 EXIST. WINDOW TO REMAIN. INSTALL WALL TYPE 2 ON STORAGE 01A SIDE. EXIST. METALSTUDS AND DRYWALL COVER WINDOW ON LOBBY/CORRIDOR SIDE.
A29 INSTALL STEEL LINTEL AT NEW WINDOW OPENING CONSISTING OF (2) 5" X 3 1/2" X 5/16"STEEL ANGLES.
A30 INSTALL HOLLOW METAL CASED OPENING AT NEW OPENING; WRAP WALL, PAINT.
A31 PLASTIC LAMINATE WARDROBE CABINET.
SCALE: 1/4" = 1'-0"A401
2 INT. ELEV.SCALE: 1/4" = 1'-0"A401
3 INT. ELEV.
SCALE: 1/4" = 1'-0"A401
4 INT. ELEV.SCALE: 1/4" = 1'-0"A401
5 INT. ELEV.
INTERIOR ELEVATION KEYNOTEST1 GYP. BD. WALL TO BE PAINTED.
T2 TOILET (SEE PLUMB.)
T3 NEW TOILET PAPER DISPENSER (PROVIDED BY OWNER, INSTALLED BY CONTRACTOR)
T4 WALL BASE AS SCHEDULED
T5 WALL MOUNTED GRAB BARS (PROVIDE IN WALL BLOCKING) UG3-A BY AJW ARCHITECTURALPRODUCTS.
T6 WALL MOUNTED HAND SINK TO BE INSTALLED (SEE PLUMB.)
T7 WALL MOUNTED PAPER TOWEL / ELEC. HAND DRYER (SEE MECH.)
T8 PLASTIC LAMINATE WARDROBE CABINET
T9 24" x 36" U700 SERIES ANGLE FRAME MIRROR BY AJW ARCHITECTURAL PRODUCTS,TEMPERED GLASS.(BOTT. OF REFLECTIVE SURAFACE 40" AFF.)
T10 SOAP DISPENSER (PROVIDED BY OWNER; INSTALLED BY CONTRACTOR)
T11 PLASTIC LAMINATE BASE CABINETS (SEE DETAIL 5/A501)
T12 PLASTIC LAMINATE WALL CABINETS (SEE DETAIL 5/A501)
T13 34" HIGH PLASTIC LAMINATE COUNTERTOP (SEE DETAIL 5/A501)
T14 DROP IN SINK BASIN AT WHEELCHAIR ACCESSIBLE COUNTERTOP AND BASE CABINET (SEEPLUMB.)
T15 ADA UNDER-SINK KNEEGAURD TO BE PROVIDED.
T16 PLASTIC LAMINATE PANEL OVER EXIST. PILASTERS; MATCH CABINETS.
T17 WALL MOUNTED EMERGENCY LIGHT FIXTURE (SEE ELEC.)
T18 FLOOR MOUNTED UTILITY SINK (SEE PLUMB. DWGS.)
T19 COUNTERTOP EYE WASH STATION (SEE PLUMB. DWGS.)
T20 PLASTIC LAMINATE FILLER.
Revisions
NO: DATE: DESCRIPTION:
1ST FLOOR
0' - 0"
ART HOUSE
-3' - 0"
6 R
@ 6
" EA
. =
3' -
0"
M67 X 17.6
2' -
10
"
3' -
6"
3"
A501
9
A501
10
4x4x3/8" TS POST W/ 10X10X1/4" BASE PLATE 3 1/2" ANCHOR BOLTS W/ LEVELING NUTS (TYP.)ON EXISTING CONC. SLAB.
2
A501
___________
5' - 8" 5T @ 11" EA. = 4' - 7"
3' -
7 3
/4"
UP
1' - 0"
1 1
/2"
4' -
2 1
/4"
+/-
3' -
0"
1 1
/2"
9"
9"
1 1
/2"
1' - 0"
1' - 0"
2"
1ST FLOOR
0' - 0"
ART HOUSE
-3' - 0"
MA
TCH
EXI
ST.
HEI
GH
T
2' -
10
" +
/-
3 5/8" METAL STUD@ 16" O.C.
5/8" GYP. BD., PAINT.
BASE AS SCHEDULED
REINF. CMU INFILL AS REQ'DTO MATCH ADJACENT WALLTHICKNESS (SEE PLAN)
NEW WINDOW TO BE INSTALLED(SEE PLAN)
INDICATES NEW STAIR HANDRAIL,PROVIDE 1 1/2" CLEAR AT INTERSECTION OF RAIL AND COUNTER
5/8" GYP. BD., PAINT.
CLR. MIN.1 1/2"
10" +/-
11
A501
___________
PLASTIC LAMINATE COUNTERTOPON 3/4" PLYWOOD (TYP.)
BASE CABINET, SIZE AS SHOWNON INT. ELEVATIONS.
RUB. BASE
FIN. FLOOR (AS SCHEDULED)
FACE OF WALL (PROVIDE BLOCKING
FOR MOUNTING CABINETS)(FINISH AS SCHEDULED)
WALL CABINET, SIZE AS SHOWNON INT. ELEVATIONS.
3/4" PLASTIC LAMINTE FACEDWD EDGE BAND
2' -
10
"2
' - 2
"2
' - 6
"
1' - 0"
4"
PLASTIC LAMINATE BACKSPLASH
2' -
10
"
GENERAL NOTES:
ALL STAIR, LANDINGS, POSTS, STRINGERS, AND RAILING COMPONENTS TO BE HOT DIPPED GALVANIZED. ALL FIELD WELDS TO BE TOUCHED UP WITH GALVANIZING PAINT.
1.
PROVIDE SHOP DRAWINGS SHOWING ALL DESIGN SIZES AND CONNECTIONS CERTIFIED BY A PROFESSIONAL ENGINEER LISCENSED IN NEW YORK STATE, TO THE ARCHITECT FOR APPROVAL PRIOR TO FABRICATION.
2.
1 1/2" O.D. POST 5'-0" MAX. O.C. (TYP.)
CL
3/4" DIA. STL. HANDRAILBRACKET @ 5'-0" O.C. MAX.
MOUNT AS REQ'D. TO STL. STAIR AND LANDING STRINGER.
3' -
6"
1 1/2" O.D. STL. GUARDRAIL (1.90" ACTUAL)
1 1/4" O.D. STL.PIPE HANDRAIL(1.35" ACTUAL)
1 1/2"
PROVIDE MATERIALS WITH SMOOTH, FLAT SURFACES, UNLESS OTHERWISE INDICATED.
STEEL PLATES, SHAPES, BARS - ASTM A36/A36MSTEEL TUBING - ASTM A500, GRADE C COLD ROLLEDSTEEL PIPE - ASTM A53 (SCH 40)BAR GRATING - GCM SERIES BY MCNICHOLS (OR EQUAL).
MEETS ADA (1" X 3/16" BARS) GALVANIZED STEEL.TREAD GRATING - GW SERIES BY MCNICHOLS (OR EQUAL)
MEETS ADA, GALVANIZED STEEL.
3.
4"
1' -
0"
EQEQ
STEEL GRATING
B/B M67 X 17.6
C12 X 10.6
M67 X 17.6
C12 X 10.6
M67 X 17.6BOLT TO EXIST. WALL
C12 X 10.6
4x4x3/8" TS POST W/ 10X10X1/4" BASE PLATE 3 1/2" ANCHOR BOLTS W/ LEVELING NUTS (TYP.)ON EXISTING CONC. SLAB.
FACE OF GYP. BD. WALL.
WD. BLOCKING AS REQ'D.
COVERPLATE
2' - 10"
1 1/4" O.D. STL.PIPE HANDRAIL (PT.)(1.35" ACTUAL)
3/4" DIA. STL. HANDRAILBRACKET @ 5'-0" O.C. MAX (PTD.)
1 1/2"
7/8" METAL HAT CHANNEL FURRING(SEE PLAN)
EXIST. CMU WALLCONSTRUCTION BEYOND
ANCHOR HANDRAIL BRACKET TO EXIST. CONC.
STL C12x10.6 STRINGER
1 1/4" x 1 1/4" x 3/16" CARRIER ANGLE
STEEL GRATE TREAD
1/4" CLOSURE PLATE, WELD TO END OF STRINGERS, TOP AND BOTTOM OF STRINGER.
STEEL RISER PLATE
STEEL NOSING
1/2" DIA. EXPANSION BOLT
CLIP ANGLE 3" x 3" x 1/4"
EXIST. CONC. SLAB TO REMAIN
STL C12x10.6 STRINGER
STEEL GRATE TREAD
STEEL RISER PLATE
STEEL NOSING
B/B M67 X 17.6
4x4x3/8" TS POST
STEEL GRATE LANDING12
A501
___________
500 East Sixth StreetJamestown, NY 14701716-483-3153
labellapc.com
DRAWING NAME:
It is a violation of New York Education Law Article 145 Sec.7209, for any person, unless
acting under the direction of a licensed architect, professional engineer, or land
surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or
land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the
item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the
DOOR SCHEDULE COMMENTS:1. 2” X 4 ½” THERMALLY BROKEN ALUMINUM STOREFRONT SYSTEM BY TUBELIGHT OR EQUIVALENT, WITH EXTRA DARK BRONZE ANODIZED FINISH FRAME, AND
BLENDED CUSTOM COLOR PVDF ENTRANCE DOOR 01-1, EXTRA DARK BRONZE ANODIZED DOOR 02-3.
2. BARNCRAFT FRESNO FARMHOUSE INTERIOR BARN DOOR BY RUSTIC ROLLING DOORS, ENGINEERED DOOR CORE WITH CANADIAN PINE PLANKS, 1 ½” THICK (PLANK DESIGN ON ONE SIDE), BLACK-PAINTED EDGES, PRE-FINISHED, WITH CLASSIC STRAP SINGLE BARN DOOR HARDWARE KIT, FLAT BLACK FINISH, WITH DUAL-SIDED DOOR PULL AND FLUSH HANDLE AND ASSOCIATED MOUNTING PLATES, ETC., FLAT BLACK FINISH, WITH WALL-MOUNTED ADUSTABLE DUAL WHEEL FLOOR GUIDE, FLAT BLACK FINISH. DOOR 05-1 TO KILN ROOM WILL REQUIRE CLASSIC STRAP BYPASS BARN DOOR HARDWARE KIT. (INSTALL BLOCKING AS REQUIRED INSIDE WALLS.)
3. CLOPAY MODEL 904 OVERHEAD DOOR WITH INSULATED GLAZING PANELS. SECTIONS ARE 2 1/8” THICK ALUMINUM EXTRUSION CONSTRUCTION, DARK BRONZE ANODIZED CONSTRUCTION, WITH GALVANIZED STEEL 14 GA. HORIZONTAL AND 16 GA. VERTICAL TRACK SECTIONS, POWERED BY LIFTMASTER MODEL T (TROLLEY) LOGIC 5.0 COMMERCIAL DOOR OPERATOR, HP AS REQUIRED FOR DOOR, WITH COMMERCIAL PROTECTOR SYSTEM TO AUTO-REVERSE THE DOOR IF AN ENTRAPMENT PROTECTION DEVICE DETECTS AN OBSTRUCTION.
4. AUTOMATIC DOOR OPERATOR WITH INTERIOR AND EXTERIOR PUSH-PADS. (REFER TO ELECTRICAL DRAWINGS FOR MORE INFORMATION.)
5. PAIR OF BI-FOLD DOORS.
6. PAIR OF BYPASS DOORS.
ROOM FINISH SCHEDULE COMMENTS:
1. POLYUREA FLOOR CONCRETE COATING REFINISHING SYSTEM BY APOLLO CONCRETE COATINGS, OR EQUIVALENT. PREPARATION TO INCLUDE DIAMOND GRINDING TO ACHIEVE THE PROPER CONCRETE SURFACE PROFILE BASED ON THE MANUFACTURER’S RECOMMENDATIONS. REMOVE ANY EXISTING SEALERS. REPAIR VISIBLE CRACKS WITH POLYUREA CONCRETE MENDER. OPEN UP MORE SEVERE OR WIDER CRACKS TO CLEAN AND ABRADE BOTH SIDES OF THE CRACKS. FILL PITTED OR SPALLED AREAS TO LEVEL OFF LOW SPOTS. DIAMOND GRIND ENTIRE AREA AGAIN TO TAKE DOWN ANY HIGH SPOTS AND SCARIFY THE MENDER. PROVIDE LEVELING COMPOUND AS REQUIRED. APPLY BASE COATING OF SELF-PRIMING POLYUREA TO THE ENTIRE FLOOR. BROADCAST VINYL COLOR CHIPS (COLORS AS SELECTED BY THE ARCHITECT) INTO THE WET BASE COAT TO ACHIEVE UNIFORM COLOR AND TEXTURE. SCRAPE CHIPS AS REQUIRED TO REMOVE ANY ROUGH AREAS OR CHIPS THAT DID NOT ADHERE. VACUUM THOROUGHLY. APPLY POLYASPARTIC POLYUREA 2 PART CHEMICAL TOP CLEAR COAT.
2. 4” RUBBER BASE BY ROPPE OR EQUIVALENT, COLOR AS SELECTED BY ARCHITECT.
3. REFER TO REFLECTED CEILING PLAN FOR ADDITIONAL INFORMATION REGARDING CEILING FINISHES.
4. PROMAR 200 ZERO V.O.C. INTERIOR LATEX EG-SHEL BY SHERWIN WILLIAMS FOR GYPSUM BOARD WALLS, INTERIOR LATEX FLAT FOR GYPSUM BOARD CEILINGS, TWO TOP COATS AND PRIMER COAT. COLORS AS SELECTED BY ARCHITECT.
SHER-CRYL HPA HIGH PERFORMANCE ACRYLIC SEMI-GLOSS COATING FOR HOLLOW METAL DOORS AND FRAMES, EXPOSED STEEL COLUMNS AND BEAMS AND CONCRETE BLOCK; TWO TOP COATS AND PRIMER COAT. COLORS AS SELECTED BY ARCHITECT.
PRO-INDUSTRIAL WATERBORNE ACRYLIC DRYFALL PAINT BY SHERWIN WILLIAMS FOR EXPOSED WOOD STRUCTURE; TWO TOP COATS AND PRIMER COAT. COLORS AS SELECTED BY ARCHITECT.
PERCENTALTERNATING CURRENTADJACENTABOVE FINISHED FLOORABOVE FINISHED GRADEALTERNATEAMBIENTAMPERE (AMP,AMPS)AMERICAN NATIONAL STANDARD INSTITUTEAPPROXIMATE (LY)AVERAGEBACKFLOW PREVENTERBRAKE HORSEPOWERBUILDINGBOTTOM OFBASEMENTBRITISH THERMAL UNITBALANCING VALVECAPACITYCAST IRON PIPECEILINGCLEARCLEANOUT or CARBON MONOXIDECOLUMNCONNECTIONCONCRETECONTINUOUSCUBIC FEETVALVE FLOW COEFFICIENTDOMESTIC COLD WATERDOUBLE CHECK DETECTOR ASSEMBLYDETECTOR CHECK VALVEDOMESTIC COLD WATERDEMOLISH or DEMOLITIONDOMESTIC HOT WATERDIAMETERDUCTILE IRON PIPEDOMESTIC WATER HEATERDRAIN, WASTE, & VENTDRAWINGEXISTINGENGINEEREQUALESTIMATEDEXISTING TO REMAINELECTRIC WATER HEATERENTERING WATER TEMPERATUREEXISTINGEXISTINGEXPANSIONEXTERIORDEGREES FAHRENHEIT
FREE AREAFIRE DEPARTMENT CONNECTIONFINISHED FLOORFULL LOAD AMPSFEET PER MINUTEFEET PER SECONDFOOT OR FEETFUTUREGAGE OR GAUGEGALLONSGENERAL CONTRACTORGALLONS PER MINUTEGALLONS PER DAYGALLONS PER HOURHEADMERCURYHORIZONTALHORSEPOWERHIGH PRESSURE CONDENSATEHIGH PRESSURE STEAMHOURHEATING, VENTILATING, AND AIR CONDITIONINGFREQUENCYDIAMETER, INSIDEINCHINSULATIONINTERIORIRON PIPE SIZEINVERTKILOWATTKILOWATT HOURPOUNDSLINEAR FEETLENGTHLOCATIONLOW PRESSURE CONDENSATELOW PRESSURE STEAMLOCKED ROTOR AMPSLEAVING WATER TEMPERATUREMATERIALMAXIMUMBTU PER HOUR (THOUSAND)MECHANICALMANUFACTURERMINIMUMMISCELLANEOUSMAXIMUM OVERCURRENT PROTECTIONMEDIUM PRESSURE CONDENSATEMEDIUM PRESSURE STEAMMOUNTINGNOT APPLICABLENORMALLY CLOSED
NOT IN CONTRACTNORMALLY OPENNATIONAL PIPE TREADNON-RISING STEMNOT TO SCALEON CENTERDIAMETER, OUTSIDEOUTSIDE SCREW AND YOKEPLUMBING CONTRACTORPLUMBINGPHASE (ELECTRICAL)PRESSUREPOUNDS PER SQUARE FOOTPOUNDS PER SQUARE INCHPSI GUAGEPRESSURE REDUCING VALVERECEIVERRECIRCULATEHOT WATER RE-CIRCULATIONROUGH OPENINGREDUCED-PRESSURE DETECTOR ASSY.REVOLUTIONS PER MINUTEREDUCED-PRESSURE ZONESPECIFICATIONSUPPLYSQUARESQUARE FOOT (FEET)SQUARE INCH (INCHES)STANDARDSUCTIONTHERMOSTATTO BE DETERMINEDTEMPERATURE DIFFERENCETEMPERATURETHERMOSTATIC MIXING VALVETAMPER SWITCHTYPICALVOLTVACUUMVARIABLEVELOCITYVERIFY IN FIELDVOLUMEWATTWITHWITH OUTWALL CLEANOUTWATER HAMMER ARRESTERWATER METERWATER PRESSURE DROPWEIGHTWORKING WATER PRESSURE
NOTE: SOME ABBREVIATIONS MAY NOT BE USED ON DRAWINGS
1
1
M-2
A
M-2
A
PIPE, EQUIPMENT TO BE REMOVED
NOTE:NOT ALL SYMBOLS, ABBREVIATIONS ANDEQUIPMENT DESIGNATIONS MAY APPLY TO THISPARTICULAR PROJECT. ANY ADDITIONS OROMISSIONS FROM THIS LEGEND SHEET DOES NOTIMPLY INCLUSION AND/ OR EXCLUSIONS OF ANYPARTICULAR ITEM FROM THIS PROJECT.
GENERAL NOTES
FIRE PROTECTION
FP
BY EXECUTING THE CONSTRUCTION AGREEMENT, THE CONTRACTOR REPRESENTS THAT THEY HAVE VISITED THE SITE, FAMILIARIZED THEMSELVES WITH THE LOCAL CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED, CORRELATED THEIR OBSERVATIONS WITH ALL THE REQUIREMENTS OF THE CONTRACT DOCUMENTS, AND IS AWARE OF THE OWNER'S INTENDED USE OF THE PROJECT AREA. ANY AREAS WHERE ADDITIONAL INFORMATION ARE TO BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE OWNER, IN WRITING.
ORDINARY HAZARD, GROUP 1
FIRE PROTECTION CRITERIA LEGEND
HAZARD CLASSIFICATIONCRITERIA
SYMBOL
ROOMS WITH SUSPENDED CEILINGS
SPRINKLER HEAD TYPES
DAY ROOM, ALL VESTIBULES, LOBBIES, AND CORRIDORS
ROOMS WITH NO CEILINGS
0'-0" TO 7'-0" FROM FACE OF UNIT HEATERS
2'-0" ABOVE BOTTOM OF ELEVATOR SHAFT
ROOM TYPE FINISH MANUFACTURER MODEL
SEMI-RECESSED
UPRIGHT
CONCEALED
SIDEWALL
CHROME
BRASS
WHITE
CHROME
VARIES
VIKING
7'-0" TO 20'-0" FROM FACE OF UNIT HEATERS VARIES
BRASS
BRASS
SPRINKLER HEAD
TEMP. RATING
165 F
165 F
165 F
165 F
HIGH (286 F)
INTERMEDIATE (200 F)
VIKING
VIKING
VIKING
VIKING
VIKING
HORIZON 06697B
MICROMATIC 10138
HORIZON MIRAGE
MICROMATIC HP
VARIES
VARIES
THE CONTRACTOR SHALL INSTALL WORK SUBSTANTIALLY AS INDICATED ON THE DRAWINGS. VERIFY EXACT LOCATION AND ELEVATIONS AT THE SITE. DO NOT SCALE THE DRAWINGS. MAKE NECESSARY CHANGES IN ELEVATION, FITTINGS, OR OFFSETS TO ACCOMMODATE OBSTACLES OR INTERFERENCES. ALL DIMENSIONS ARE TO BE FIELD VERIFIED BEFORE START OF WORK.
THE CONTRACTOR IS TO PROTECT FURNISHINGS, EQUIPMENT, ETC. AND PROPERLY STORE MATERIAL REQUIRED UNTIL COMPLETION OF THE PROJECT.
CONTRACTOR TO VERIFY ALL MEASUREMENTS BEFORE ORDERING MATERIALS OR DOING ANY WORK. NO EXTRA COMPENSATION OR CHANGE ORDERS WILL BE ISSUED DUE TO DIFFERENCES BETWEEN ACTUAL MEASUREMENT AND DIMENSIONS ON THE DRAWINGS. CONTRACTOR SHALL LAY OUT ALL EQUIPMENT PRIOR TO FABRICATION OR INSTALLATION TO ASSURE PROPER FIT AND AVOIDANCE OF OBSTRUCTIONS, AND SHALL THOROUGHLY COORDINATE WORK WITH ALL TRADES AND DETERMINE EXACT ROUTE AND LOCATION OF EACH ELEMENT AND PIECE OF EQUIPMENT BEFORE FABRICATION AND INSTALLATION.
CONTRACTOR IS TO BE RESPONSIBLE FOR KEEPING THE GENERAL WORK AREA CLEAN AND FREE FROM DIRT AND CONSTRUCTION MATERIALS, AND CLEANING THE AREA THE END OF EACH DAY. ANY AND ALL DAMAGE TO THE EXISTING WALLS, CEILINGS, FLOOR, ETC. THAT OCCURS DURING THE WORK, SHALL BE REPAIRED AND PATCHED. IF THE SPECIFIC METHOD OF REPAIR IS IN QUESTION, THE CONTRACTOR IS TO CONFER WITH THE OWNER’S REPRESENTATIVE BEFORE COMMENCING THE REPAIR.
THE CONTRACTOR SHALL MAINTAIN ON THE SITE FOR THE OWNER A COMPLETE SET OF CONTRACT DOCUMENTS AND ALL COPIES OF APPROVED SHOP DRAWINGS. ALL CHANGE ORDERS, FIELD ORDERS, AND BULLETINS, PROGRESSIVELY FILED AND UPDATED TO REFLECT THE LATEST CHANGES.
1.
2.
3.
4.
THE CONTRACTOR IS TO PROVIDE AS-BUILT DRAWINGS AT THE COMPLETION OF THE PROJECT.
CONTRACTOR ACKNOWLEDGES THEY HAVE VERIFIED WITH THE OWNER’S REPRESENTATIVE ALL OF THE DETAILS OF THE WORK PERFORMED INCLUDING THE ACCURACY OF ALL CONTRACT DRAWINGS AND SPECIFICATIONS. ALL MATERIALS AND EQUIPMENT ARE TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S RECOMMENDATIONS AND SPECIFICATIONS, UNLESS NOTED OTHERWISE.
ALL DEFECTS IN EQUIPMENT OR MATERIALS, OR ERRORS IN THE DRAWINGS DISCOVERED DURING THE PERFORMANCE OF THE WORK SHALL BE REPORTED PROMPTLY TO THE OWNER’S REPRESENTATIVE. IN NO EVENT SHALL THE WORK PROCEED UNTIL DEFECTS AND/OR ERRORS HAVE BEEN RESOLVED.
5.
6.
7.
8.
CODES AND REGULATIONS:
9.
THE CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, RULES, REGULATIONS, AND ORDERS OF ANY PUBLIC AUTHORITY BEARING ON THE PERFORMANCE OF THE WORK, BOTH ON AND OFF SITE. IF ANY OF THE CONTRACT DOCUMENTS ARE AT VARIANCE THEREWITH IN ANY RESPECT, CONTRACTOR SHALL PROMPTLY NOTIFY THE OWNER’S REPRESENTATIVE IN WRITING.
CONTRACTOR REPRESENTS AND WARRANTS COMPLIANCE WIT HALL FEDERAL, STATE, AND LOCAL LAWS, ORDNANCES AND REGULATIONS APPLICABLE TO THIS ORDER, INCLUDING THE NEW YORK STATE BUILDING CODE, AND LOCAL GOVERNING BODY.
1.
2.
FINAL COMPLETION:
PERFORM ALL OF THE WORK REQUIRED TO COMPLETE THE PROJECT, INCLUDING THE SATISFACTORY OPERATION OF ALL EQUIPMENT, AND THE CORRECTION OF ALL UNACCEPTABLE OR INCOMPLETE PORTIONS OF THE PROJECT TO THE SATISFACTION OF THE OWNER'S REPRESENTATIVE, SETTLE ALL CLAIMS AND SECURE RELEASE OF ALL MECHANICS LIEN OR LEINS OF A LIKE NATURE, AND SECURE THE ISSUANCE BY AN APPROPRIATE GOVERNMENT AUTHORITY OF A CERTIFICATE OF OCCUPANCY. REMOVE ALL RUBBISH, SURPLUS MATERIALS, SCAFFOLDING, AND EQUIPMENT FROM THE SITE WHETHER OR NOT LEFT BY OR BELONGING TO THE CONTRACTOR.
1.
FIRE PROTECTION NOTES
BUILDING CODE JURISDICTION: CITY OF JAMESTOWN
1. BUILDING CODE OF NEW YORK STATE.
2. ENERGY CODE OF NEW YORK STATE.
3. PLUMBING CODE OF NEW YORK STATE.
4. MECHANICAL CODE OF NEW YORK STATE.
5. FIRE CODE OF NEW YORK STATE.
6. ENERGY CONVERSATION CODE OF NEW YORK STATE.
7. ACCESSIBLE AND USABLE BUILDING AND FACILITIES - CABO/ANSI.A117.1 - 2009
8. NATIONAL ELECTRIC CODE 2005.
9. NATIONAL FIRE CODE: NFPA 13.
10. CODE OF THE CITY OF JAMESTOWN
THE DESIGN PRELIMINARY SHOWN ON THESE CONTRACT DOCUMENTS IS TO PROVIDE GUIDANCE FOR BIDDING AND TO OBTAIN APPROVAL OF THE AUTHORITIES HAVING JURISDICTION. SUBMIT COMPLETE FIRE SPRINKLER SHOP DRAWINGS AS REQUIRED BY CONTRACT DOCUMENTS TO THE OWNER'S DESIGNATED REVIEWER. BASE DESIGN UPON THESE DRAWINGS AND AS REQUIRED BY THE SPECIFICATIONS. SHOP DRAWINGS SHALL INCLUDE ELEVATIONS, HANGER LOCATIONS, PIPE LENGTHS, DIMENSIONS, FABRICATION METHODS, MATERIAL DATA, AND ADDITIONAL INFORMATION NECESSARY TO CLARIFY THE INTENT OF INSTALLATION. CONTRACTOR SHALL PROVIDE PIPE SIZE, SPRINKLER SPACING, AND SYSTEM CONFIGURATION AS SHOWN. ALTERNATES MUST BE APPROVED IN WRITING BY FIRE PROTECTION ENGINEER OF RECORD DOCUMENTS PRIOR TO BID.
NOTE CAREFULLY THAT THE FIRE PROTECTION DRAWING ARE INTENDED TO INDICATE, ONLY DIAGRAMMATICALLY, TO THE EXTENT AND GENERAL CHARACTER AND LOCATIONS OF THE WORK INCLUDED. PROVIDE ALL WORK OBVIOUSLY INTENDED, BUT HAVING MINOR DETAILS OMITTED OR NOT SHOWN. COMPLETE AS REQUIRED TO PERFORM THE FUNCTIONS INTENDED. FOLLOW THE CONTRACT DOCUMENTS FOR BUILDING DETAILS AND FIT THE WORK OF THE FIRE PROTECTION DRAWINGS AND SPECIFICATIONS THERETO.
CONTRACTOR IS RESPONSIBLE FOR OBTAINING CURRENT HYDRANT TEST DATA (PERFORMED WITHIN LAST 6 MONTHS) AND PERFORMING HYDRAULIC CALCULATIONS: THE CONTRACTOR MAY RESIZE SPRINKLER PIPING IN ACCORDANCE TO HYDRAULIC CALCULATIONS.
COORDINATE LOCATIONS OF FIRE PROTECTION COMPONENTS, INCLUDING PIPING, ALARMS, RAINS, TEST POINTS, ETC. WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL, AND ELECTRICAL COMPONENTS. OBSTRUCTION TO SPRINKLER DISCHARGE MUST BE CONSIDERED DURING SHOP DRAWING PRODUCTION AND INSTALLATION: ADDITIONAL SPRINKLERS MAY BE REQUIRED AT NO ADDITIONAL COST TO OWNER, REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
SUBMIT A REQUEST FOR INFORMATION FOR QUESTIONS REGARDING THE FIRE PROTECTION DOCUMENTS.
CONTRACTOR MUST REVIEW ALL CONSTRUCTION DOCUMENTS PRIOR RO BID. SHOULD MODIFICATIONS TO THESE PLANS BECOME NECESSARY TO PROPERLY COORDINATE THE SYSTEM WITH ALL OTHER TRADES. IT WILL BE THE CONTRACTOR'S RESPONSIBILITY TO OBTAIN APPROVAL OF THE CHANGES FROM BOTH THE AUTHORITY HAVING JURISDICTION AND THE OWNER'S DESIGNATED REVIEW CONSULTANT IN ADDITION TO OBTAINING THE NECESSARY APPROVALS. THE CONTRACTOR MUST MAKE NOTE OF ANY FIELD OR COORDINATION CHANGES ON THE INSTALLATIONS DRAWINGS, AND PROVIDE A SET OF AS-BUILT DRAWINGS ONCE COMPLETE.
1.
2.
3.
4.
CONTRACTOR SHALL ROUTE PIPING AROUND ALL OBSTRUCTIONS AND PROVIDE SPRINKLER PROTECTION UNDER OBSTRUCTIONS AS DETAILED IN NFPA 13 AS PART OF THE FIELD COORDINATION AT NO ADDITIONAL COST TO OWNER.
ALL SPRINKLER DEFLECTOR DISTANCE REQUIREMENTS SHALL BE IN ACCORDANCE WITH NFPA 13.
PENETRATIONS OF RATED ASSEMBLIES SHALL BE FIRE STOPPED WITH APPROVED MATERIALS PER METHODS DESCRIBED BY THE UL FIRE RESISTANCE DIRECTORY.
5.
6.
7.
8.
9.
PROVIDE FLUSHING CONNECTIONS IN ACCORDANCE WITH NFPA 13.10.
PROVIDE ALL NECESSARY OFFSETS, RAISES, OR DROPS IN PIPING AND AUXILIARY DRAINS REQUIRED BY BUILDING CONDITIONS. PIPE ELEVATION CHANGES ARE APPROXIMATE DIMENSIONS ONLY.
11.
ALL MATERIALS SHALL BE UL LISTED OR FM APPROVED. SPRINKLER PIPE SHALL BE MANUFACTURED TO STANDARDS RECOGNIZED BY NFPA 13. THREADED PIPE SHALL HAVE A CORROSION RESISTANCE RATING OF 1.0 OR GREATER. CRIMP-TYPE COUPLERS SHALL NOT BE USED.
12.
HYDROSTATICALLY TEST NEW ABOVE GROUND SPRINKLER PIPING FOR LEAKAGE IN PRESENCE OF AUTHORITY HAVING JURISDICTION.
13.
ROUTE SPRINKLER MAINS ABOVE BOTTOM CHORD OF JOISTS AND FOLLOW PITCH/SLOPE OF ALL CEILING PLANES WHERE PIPING IS EXPOSED.
14.
REFER TO ARCHITECTURAL DRAWINGS FOR ALL CEILING AND WALL ELEVATIONS.15.
FIRE SPRINKLER REVIEWING AUTHORITY HAVING JURISDICTION: CITY OF JAMESTOWN
BUILDING DEPARTMENT: CITY OF JAMESTOWN
SPRINKLER DRAINSD
WP WET PIPE
CROSS MAIN CONNECTION
LIGHT HAZARD
CONTACT INFORMATION
PROVIDE DRAWINGS AND CALCULATIONS STAMPED BY AN ENGINEER LICENSED IN THE STATE OF NEW YORK.
16.
CONCEALED PENDANT SPRINKLER HEAD
DRY PENDENT / DRY SYSTEM
DRY UPRIGHT / DRY SYSTEM
DRY SIDEWALL / DRY SYSTEM
DUCTILE IRON PIPEDIP
SPRINKLER DRAINSD
WP WET PIPE
FIRE PROTECTION SYMBOLS
BACKFLOW PREVENTERBFP
PIPE UP
PIPE DOWN
CROSS MAIN CONNECTION
FIRE DEPARTMENT CONNECTIONF.D.C.
TAMPER SWITCHTS
CHECK VALVE
DRY UPRIGHT / WET SYSTEM
DRY PENDENT / WET SYSTEM
INSTITUTIONAL SIDEWALL
INSTITUTIONAL PENDENT
UPRIGHT WITH GUARDG
I
I
F
F
D
D
D
PENDENT / WET SYSTEM
UPRIGHT / WET SYSTEM
500 East Sixth StreetJamestown, NY 14701716-483-3153
labellapc.com
DRAWING NAME:
It is a violation of New York Education Law Article 145 Sec.7209, for any person, unless
acting under the direction of a licensed architect, professional engineer, or land
surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or
land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the
item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the
alteration.
DRAWING NUMBER:
DATE:
ISSUED FOR:
DRAWN BY:
REVIEWED BY:
PROJECT NUMBER:
6/18
/202
1 9
:22:
09
AM
F001
FIRE PROTECTION LEGEND
SHEET
JLJ
JSN
6-18-21
ISSUED FOR CONSTRUCTION
2192683.01
712 W. EIGHTH STREETJAMESTOWN, NY 14701
EDGEWATER ART HOUSE
THE RESOURCE CENTER
Revisions
NO: DATE: DESCRIPTION:
ART CLASSROOM02
ELEC.01C
JANITOR01B
TOILET03
SHOP/DISPLAY01
STORAGE01A
PASSAGE04
KILN05
STORAGE05A
CORRIDOR02A
PROVIDE HIGH TEMPERATURE
SPRINKLER HEADS ABOVE KILN
PROVIDE SIDE WALL SPRINKLER BELOW
GARAGE DOOR IN OPEN POSITION
PROVIDE SIDE WALL SPRINKLER BELOW
GARAGE DOOR IN OPEN POSITION
1
1
1
500 East Sixth StreetJamestown, NY 14701716-483-3153
labellapc.com
DRAWING NAME:
It is a violation of New York Education Law Article 145 Sec.7209, for any person, unless
acting under the direction of a licensed architect, professional engineer, or land
surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or
land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the
item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the
alteration.
DRAWING NUMBER:
DATE:
ISSUED FOR:
DRAWN BY:
REVIEWED BY:
PROJECT NUMBER:
6/18
/202
1 9
:22:
09
AM
F101
FIRST FLOOR FIRE
PROTECTION PLAN
JLJ
JSN
6-18-21
ISSUED FOR CONSTRUCTION
2192683.01
712 W. EIGHTH STREETJAMESTOWN, NY 14701
EDGEWATER ART HOUSE
THE RESOURCE CENTER
1/4" = 1'-0"F101
1 FIRST FLOOR FIRE PROTECTION PLAN
N
GENERAL NOTES:
1. SEE F001 FOR HATCHING LEGEND.2. PAINT ALL EXPOSED SPRINKLER PIPING, COORDINATE WITH ARCHITECT ON COLOR.
KEY NOTES:
REVISE EXISTING SPRINKLER SYSTEM HEADS AND PIPING TO ACCOMMODATE NEW WALLS AND AREA RENOVATIONS.
1
Revisions
NO: DATE: DESCRIPTION:
BRANCH OFF TOP OF PIPE
PIPE TURNED UP
PIPE TURNED DOWN
BRANCH OFF BOTTOM OF PIPE
REDUCER
PIPE BREAK
BALL VALVE
BUTTERFLY VALVE
GATE VALVE
DRAWING SYMBOLS
ANGLE VALVE
CHECK VALVE
BALANCE VALVE
SHUT OFF VALVE (GATE, BALL,OR BUTTERFLY - REFER TO SPECS)
MOTOR OR SOLENOIDCONTROL VALVE (3-WAY)
STEAM TRAP
MOTOR OR SOLENOIDCONTROL VALVE
PRESSURE REDUCING VALVE
TRIPLE DUTY VALVE
RELIEF VALVE
STRAINER
UNION
PRESSURE GAUGE
PUMP
EQUIPMENT TO BE REMOVED
KEYNOTE
SECTION CALLOUT
NEW CONNECTION TO EXISTING
REMOVE TO THIS POINT)
DEMOLITION KEYNOTE
DETAIL NUMBER
RETURN AIR
SUPPLY AIR
DUCT (DIMENSIONS SHOWN INDUCT. DIMENSIONS IN INCHES.)
DUCT SECTION - EXHAUST AIR
DUCT SECTION - SUPPLY AIR
DUCT SECTION - RETURN AIR
14" ROUND DUCT
VOLUME DAMPER
DUCT (DIMENSIONS SHOWN BYLEADER. DIMENSIONS IN INCHES.)
14" Ø
MITERED ELBOW W/ TURNING VANES
INTERNALLY INSULATED DUCT (DIM. IS INTERNAL)
EXHAUST GRILLE
REGISTER OR GRILLE - TOP NUMBERREPRESENTS TAG, SEE SCHEDULE;BOTTOM NUMBER REPRESENTS CFM.
RETURN GRILLE
DIFFUSER - LETTER REPRESENTS TAG,SEE SCHEDULE; NUMBER REPRESENTS CFM
PERCENTALTERNATING CURRENTADJACENTABOVE FINISHED FLOORABOVE FINISHED GRADEALTERNATEAMBIENTAMPERE (AMP,AMPS)AMERICAN NATIONAL STANDARD INSTITUTEAPPORXIAMTE (LY)AVERAGEBACKFLOW PREVENTERBRAKE HORSEPOWERBUILDINGBOTTOM OFBASEMENTBRITISH THERMAL UNITBALANCING VALVECAPACITYCAST IRON PIPECEILINGCLEARCLEANOUT or CARBON MONOXIDECOLUMNCONNECTIONCONCRETECONTINUOUSCUBIC FEETVALVE FLOW COEFFICIENTDOUBLE CHECK DETECTOR ASSEMBLYDETECTOR CHECK VALVEDOMESTIC COLD WATERDEMOLISH or DEMOLITIONDOMESTIC HOT WATERDIAMETERDUCTILE IRON PIPEDOMESTIC WATER HEATERDRAIN, WASTE, & VENTDRAWINGEXISTINGEXHAUST AIRENTERING AIR TEMPERATUREENGINEEREQUALESTIMATEDEXISTING TO REMAINELECTRIC WATER HEATERENTERING WATER TEMPERATUREEXISTINGEXISTINGEXPANSIONEXTERIORDEGREES FAHRENHEIT
FREE AREAFINISHEDFLOORFULL LOAD AMPSFEET PER MINUTEFEET PER SECONDFOOT OR FEETFUTUREGAGE OR GAUGEGALLONSGENERAL CONTRACTORGALLONS PER MINUTEGALLONS PER DAYGALLONS PER HOURHEADMERCURYHORIZONTALHORSEPOWERHIGH PRESSURE CONDENSATEHIGH PRESSURE STEAMHOURHEATING, VENTILATING, AND AIR CONDITIONINGFREQUENCYDIAMTER, INSIDEINCHINSULATIONINTERIORIRON PIPE SIZEINVERTKILOWATTKILOWATT HOURLEAVING AIR TEMPERATUREPOUNDSLINEAR FEETLENGTHLOCATIONLOW PRESSURE CONDENSATELOW PRESSURE STEAMLOCKED ROTOR AMPSLEAVING WATER TEMPERATUREMATERIALMAXIMUMBTU PER HOUR (THOUSAND)MECHANICALMANUFACTURERMINIMUMMISCELLANEOUSMAXIMUM OVERCURRENT PROTECTIONMEDIUM PRESSURE CONDENSATEMEDIUM PRESSURE STEAMMOUNTINGNOT APPLICABLENORMALLY CLOSED
NOT IN CONTRACTNORMALLY OPENNATIONAL PIPE TREADNON-RISING STEMNOT TO SCALEOUTDOOR AIRON CENTERDIAMETER, OUTSIDEOUTSIDE SCREW AND YOKEPLUMBING CONTRACTORPLUMBINGPHASE (ELECTRICAL)PRESSUREPOUNDS PER SQUARE FOOTPOUNDS PER SQUARE INCHPSI GUAGEPRESSURE REDUCING VALVERETURN AIRRECEIVERRECIRCULATEHOT WATER RE-CIRCULATIONROUGH OPENINGREDUCED-PRESSURE DETECTOR ASSY.REVOLUTIONS PER MINUTEREDUCED-PRESSURE ZONESUPPLY AIRSTEAM CAPTURE HOODSPECIFICATIONSUPPLYSQUARESQUARE FOOT (FEET)SQUARE INCH (INCHES)STANDARDSUCTIONTHERMOSTATTO BE DETERMINEDTEMPERATURE CONTROL CONTRACTORTEMPERATURE DIFFERENCETEMPERATURETHERMOSTATIC MIXING VALVETOP OFTYPICALVOLTVACUUMVARIABLEVELOCITYVERIFY IN FIELDVOLUMEVARIABLE REFRIGERANT FLOWWATTWITHWITH OUTWATER COLUMNWALL CLEANOUTWATER HAMMER ARRESTERWATER METERWATER PRESSURE DROPWEIGHTWORKING WATER PRESSURE
NOTE:
SOME ABBREVIATIONS MAY NOT BE USED ON DRAWINGS
1
8
750
A
125
18/8
18/8
18/8
1
M-2
A
M-2
A
M
EQUIPMENT DESIGNATIONS
HC
HP
HWP
HX
PHC
L
PRV
VAV
UH
CA
AHU
CFP
CC
B
CHP
CH
CT
CP
CAV
EF
FT
FCU
CUH
AS
CRU
CV
VD
R
CRAC
DHW
ET
FP
PRG
HU
MAU
P
PPU
RTU
RCP
UV
WS
CU
ACCU
AD
BDD
MD
VFD
EXISTING DUCTWORK, PIPE, EQUIPMENT
NEW DUCTWORK, PIPE, EQUIPMENT
DUCTWORK, PIPE, EQUIPMENT
TO BE REMOVED
CHWS
GHR
CHILLED WATER SUPPLY
GLYCOL HOT WATER RETURN
CHILLED WATER RETURNCHWR
HPLS
HPLR
HEAT PUMP LOOP SUPPLY
HEAT PUMP LOOP RETURN
GLYCOL HOT WATER SUPPLY
GHSHPC
CA
NG
C
HIGH PRESSURE CONDENSATE
COMPRESSED AIR
NATURAL GAS
CONDENSATE
VAC VACUUM
HPS HIGH PRESSURE STEAM
LPC LOW PRESSURE CONDENSATE
LPS LOW PRESSURE STEAM
MPC
MPS MEDIUM PRESSURE STEAM
RHL REFRIGERANT H/L PRESSURE
RL
RS
REFRIGERANT LIQUID
REFRIGERANT SUCTION
SV STEAM VENT
D CONDENSATE DRAIN
CTR
CTS
COOLING TOWER RETURN
COOLING TOWER SUPPLYHWS
HWR
HOT WATER SUPPLY
HOT WATER RETURN
DN
DIRECTION OF FLOW
DIRECTION OF PITCH
MU MAKE-UP WATER
PC PUMPED CONDENSATE
HOT WATER PUMP
HEAT PUMP
HEATING COIL
HEAT EXCHANGER
PREHEAT COIL
LOUVER
PRESSURE REDUCING VALVE
VARIABLE AIR VOLUME BOX
UNIT HEATER
AIR COMPRESSOR
COOLING COIL
BOILER
AIR HANDLING UNIT
CHEMICAL FEED PUMP
COOLING TOWER
CHILLER
CONDENSATE PUMP
CHILLED WATER PUMP
EXHAUST FAN
CONSTANT AIR VOLUME BOX
FINNED TUBE
FAN COIL UNIT
CABINET UNIT HEATER
AIR SEPARATOR
CONDENSATE RETURN UNIT
CONVECTOR
VOLUME DAMPER
REGISTER
COMPUTER ROOM UNIT
DOMESTIC WATER HEATER
EXPANSION TANK
FIRE PUMP
GAS PRESSURE REGULATOR
HUMIDIFIER
MAKE UP AIR UNITS
PUMP
PUMPING PACKAGED UNIT
ROOF TOP UNIT
RADIANT CEILING PANEL
UNIT VENTILATOR
WATER SOFTENER
CONDENSING UNIT
AIR-COOLIED CONDENSING UNIT
ACCESS DOOR
BACK DRAFT DAMPER
MOTORIZED DAMPER
VARIABLE SPEED DRIVE
FIRE DAMPER
SD
SMOKE DAMPER
F/SCOMBINATION FIRE / SMOKE DAMPER
AD
AD
AD
ACCESS DOOR TO BE LOCATEDON MOST ACCESSIBLE SIDE OF DUCT
ACCESS DOOR TO BE LOCATEDON MOST ACCESSIBLE SIDE OF DUCT
ACCESS DOOR TO BE LOCATEDON MOST ACCESSIBLE SIDE OF DUCT
FD
WALL OR DUCT MOUNTED SUPPLY GRILLE
WALL OR DUCT MOUNTED RETURN OR EXHAUST GRILLE
MOTOR OPERATED DAMPER
FLEX DUCT
NOTE:
SOME ABBREVIATIONS MAY NOT BE USED ON DRAWINGS
BUILDING CODE OF NEW YORK STATEMECHANICAL CODE OF NEW YORK STATEFIRE CODE OF NEW YORK STATEPLUMBING CODE OF NEW YORK STATEENERGY CONSERVATION CODE OF NEWYORK STATEACCESSIBLE AND USABLE BUILDING ANDFACILITIES-CABO/ANSI A117.1NATIONAL ELECTRIC CODENATIONAL FIRE CODE NFPA 13
12345
67
8
MEDIUM PRESSURE CONDENSATE
GENERAL NOTES
C02 CARBON DIOXIDE SENSOR
IW INDIRECT WASTE
18" x 8" FLAT OVAL DUCT18/8
CLEAN OUT
CO
PIPE CAP
PIPE THERMOMETER
FIN TUBE RADIATION
NOTE:NOT ALL SYMBOLS, ABBREVIATIONS ANDEQUIPMENT DESIGNATIONS MAY APPLY TO THISPARTICULAR PROJECT. ANY ADDITIONS OROMISSIONS FROM THIS LEGEND SHEET DOES NOTIMPLY INCLUSION AND/ OR EXCLUSIONS OF ANYPARTICULAR ITEM FROM THIS PROJECT.
RADIUSED ELBOW
GV GRAVITY VENTILATOR
ERV ENERGY RECOVERY VENTILATOR
VARIABLE AIR VOLUME BOX
DS DUCT TEMPERATURE SENSOR
M
GRH GAS-FIRED RADIANT HEATER
HRU HEAT RECOVERY BRANCH UNIT
EWH ELECTRIC WALL HEATER
GFUH GAS-FIRED UNIT HEATERAC AIR CONDITIONING UNIT
500 East Sixth StreetJamestown, NY 14701716-483-3153
labellapc.com
DRAWING NAME:
It is a violation of New York Education Law Article 145 Sec.7209, for any person, unless
acting under the direction of a licensed architect, professional engineer, or land
surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or
land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the
item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the
1 CONTRACTOR TO PROVIDE CRANE AND NECESSARY EQUIPMENT TO HOIST ROOF MOUNTED HVAC EQUIPMENT FROM SITETO FINAL ROOF LOCATION. CONTRACTOR TO PROVIDE ALL ROOF PENETRATIONS REQUIRED TO ACCOMMODATE HVACEQUIPMENT OPENINGS AND SET CURBS. CONTRACTOR TO COORDINATE EXACT LOCATION OF PENETRATIONS AND SHALLASSIST WITH SETTING ALL HVAC EQUIPMENT ROOF CURBS. CONTRACTOR SHALL BE RESPONSIBLE FOR TEMPORARYCAP OF ALL ROOF PENETRATIONS IN INTERIM FROM TIME PENETRATIONS ARE COMPLETE TO TIME EQUIPMENT IS SET ONROOF CURBS. CONTRACTOR SHALL BE RESPONSIBLE FOR FLASHING ALL EQUIPMENT CURBS AND OTHER HVACRELATED ROOF PENETRATIONS. CONTRACTOR SHALL REMOVE AND DISPOSE OF TEMPORARY CAP WHEN EQUIPMENT ISSET IN PLACE.
2 PROVIDE 45 DEGREE SHOE-TAP FITTING AND VOLUME DAMPER AT ALL BRANCH DUCT TAKE-OFFS (TOP, SIDE ANDBOTTOM) FOR SUPPLY, RETURN AND EXHAUST AIR, UNLESS SHOWN OR NOTED OTHERWISE.
3 COORDINATE HVAC INSTALLATION WITH STRUCTURE, CEILING, LIGHTING, CONDUIT, HEATING AND DOMESTIC PIPING,STORM AND SANITARY DRAIN PIPING (ALL TRADES). PREPARE AND SUBMIT FULL COORDINATION DRAWINGS FORAPPROVAL BY ENGINEER PRIOR TO ORDERING MATERIALS AND/OR BEGINNING CONSTRUCTION.
4 INSULATE OR LINE DUCTWORK AS SPECIFIED IN THE MECHANICAL INSULATION AND METAL DUCTS SPECIFICATIONS ORNOTED ON DRAWINGS. NOTE THAT DUCT SIZES SHOWN ON DRAWINGS ARE INSIDE NET CLEAR DIMENSIONS.
5 ALL 90 DEGREE RECTANGULAR ELBOWS AND DUCTWORK TEES SHALL BE HARD MITERED WITH FACTORY TURNINGVANES. TURNING VANES SHALL BE OMITTED FROM AIR TRANSFER DUCT ELBOWS.
6 ALL DUCTWORK PASSING THROUGH NON-FIRE RATED WALLS TO BE SEALED AROUND PERIMETER (BOTH SIDES) WITHDRYWALL JOINT COMPOUND OR APPROVED EQUAL.
7 CONTRACTOR TO SET MINIMUM OUTSIDE AIR DAMPER POSITION TO MEET VENTILATION AIR QUANTITIES REQUIRED ASSHOWN ON PLANS OR LISTED IN EQUIPMENT SCHEDULES.
8 ALL SUPPORT OF EQUIPMENT, DUCTWORK AND ASSOCIATED DISTRIBUTION SERVICES SHALL BE DESIGNED ANDINSTALLED IN ACCORDANCE WITH THE BUILDING CODE OF NEW YORK STATE. THE DISCIPLINE CONTRACTOR SHALL BERESPONSIBLE TO PROVIDE STRUCTURAL STEEL WHERE REQUIRED IN ORDER TO SUPPORT EQUIPMENT, DUCTWORK ANDASSOCIATED DISTRIBUTION SERVICES WHERE THE BUILDING STRUCTURE SPACING IS TOO GREAT TO ALLOW DIRECTSUPPORT. THE DISCIPLINE CONTRACTOR SHALL BE RESPONSIBLE FOR CONFIRMATION OF ALL SUPPORTS AND SHALLOBTAIN THE PROFESSIONAL SERVICE OF A STRUCTURAL ENGINEER LICENSED IN THE STATE OF NEW YORK AND FURNISHSEALED DRAWINGS AND DETAILS ILLUSTRATING SUCH SUPPORTS AND COMPLIANCE METHODS.
9 THE ABOVE GENERAL NOTES APPLY TO ALL HVAC CONSTRUCTION DOCUMENT DRAWINGS.
PIPING GENERAL NOTES
1 COORDINATE HVAC PIPING INSTALLATION WITH DUCTWORK, STRUCTURE, CEILING, LIGHTING, CONDUIT, HEATING ANDDOMESTIC PIPING, STORM AND SANITARY DRAIN PIPING (ALL TRADES). PREPARE AND SUBMIT FULL COORDINATIONDRAWINGS FOR APPROVAL BY ENGINEER PRIOR TO ORDERING MATERIALS AND/OR BEGINNING CONSTRUCTION.
2 PROVIDE ALL PIPING PENETRATIONS THROUGH WALLS, FLOORS AND DECKS REQUIRED WHERE SHOWN. SEAL ALL EXTERIORWALL PENETRATIONS WEATHER TIGHT.
3 ALL PIPING PASSING THROUGH WALLS TO BE FIRE STOPPED AND SEALED AROUND PERIMETER WITH DRYWALL JOINTCOMPOUND OR APPROVED EQUAL.
4 CONTRACTOR IS RESPONSIBLE FOR DRAINING, FILLING WITH WATER/CHEMICALS, AND AIR REMOVAL ASSOCIATED WITH ALLPIPING WORK.
5 THE ABOVE GENERAL NOTES APPLY TO ALL HVAC CONSTRUCTION DOCUMENT DRAWINGS.
Revisions
NO: DATE: DESCRIPTION:
ART CLASSROOM02
637 SF
SHOP/DISPLAY01
501 SF
ELEC.01C
TOILET03
JANITOR01B
TERRACE06
STORAGE01A
STORAGE05A
KILN05
PASSAGE04
UC
16Ø
14Ø
12Ø
AH
U-1
AH
U-2
24/16
EF-2
EF-1
UC
KH-1
WALL CAP, TYP.
5Ø KILN HOOD WALL EXHAUST LOUVER AND TAILPIPE
5Ø KILN HOOD FLEX DUCT
6Ø
6Ø
EXISTING TO REMAIN SUPPLY GRILLE
DISCONNECT AND REMOVE EXISTING GAS FIRED UNIT HEATER IN ITS ENTIRETY, INCLUDING FLUE VENT, COMBUSTION AIR INTAKE AND CONTROLS. INFILL EXISTING WALL PENETRATION TO MATCH EXISTING.
16Ø
14Ø
12Ø
215
A
TYP. 12
1
1
1
1090
1
1090
2
2
3
2
4
4
ACCU-1
ACCU-2
ON ROOF ABOVE
ON ROOF ABOVE
RS/RL ON ROOF ABOVE
5
6
6
RS/RL
72Ø EXHAUST FLUE AND
2Ø COMUSTION AIR INTAKE
CO
2Ø EXHAUST FLUE AND 2Ø COMUSTION AIR
INTAKE
D
1-1/4Ø 1-1/4Ø
24/16
9
8
9
1/4" = 1'-0"M101
1 FIRST FLOOR DUCTWORK PLAN
300 State Street, Suite 201Rochester, NY 14614585-454-6110
labellapc.com
DRAWING NAME:
It is a violation of New York Education Law Article 145 Sec.7209, for any person, unless
acting under the direction of a licensed architect, professional engineer, or land
surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or
land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the
item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the
1. PROVIDE SUPPLY GRILLE AS SCHEDULED, BALANCE TO AIRFLOW SHOWN, AND ADJUST BLADES TO 45° DOWNWARD DEFLECTION.
2. 8Ø OUTDOOR AIR DUCT UP TO GOOSENECK AT ROOF ABOVE. PROVIDE WITH BALANACE DAMPER AND BALANCE TO 210 CFM. PROVIDE WITH LOW VOLTAGE DAMPER IN RISER. INTERGRATE INTO PROGRAMMABLE TIMECLOCK AND SCHEDULE FOR DAMPER TO OPEN DURING OCCUPIED HOURS AND CLOSE DURING UNOCCUPIED HOURS.
3. PROVIDE RETURN GRILLE AS SCHEDULED. MOUNT TO UNDERSIDE OF RETURN DUCT.
4. HANG SPIRAL DUCT TIGHT TO UNDERSIDE OF ROOF STRUCTURE.
5. (2) PAIRS OF RS/RL PIPING UP TO ROOF THROUGH PIPE PORTAL. ROUTE REFRIGERATION PIPING TO CORRISPONDING ACCU AS SHOWN. SIZE AND INSTALL PER MANUFACTURER'S RECOMMENDATIONS.
6. PROVIDE ACCU AS SCHEDULED. PROVIDE AND SET UNIT ON 18" H EQUIPMENT RAILS. INSTALL EQUIPMENT RAILS PERPENDICULAR TO ROOF STRUCTURE AND SPAN (2) STRUCTURAL MEMBERS AT MINIMUM. ALL ROOFING WORK TO BE FURNISHED BY BONDED ROOFING CONTRACTOR TO PRESERVE EXISTING ROOF WARRANTY, COORDINATE ALL REQUIREMENTS WITH OWNER.
#
7. 2Ø EXHUAST FLUE AND 2Ø COMBUSTION AIR INTAKE THROUGH PIPE PORTAL TO CONCENTRIC VENT AT ROOF ABOVE.
8. 1-1/4Ø CONDENSATE DRAIN DOWN TO MOP SINK. TERMINATE OPEN-ENNED.
9. 2" FILTER RACK WITH FILTER PULL CLEARANCE.
Revisions
NO: DATE: DESCRIPTION:
1"R
2"R
FRONT VIEW SIDE VIEW
TYPICAL ELBOW
4 "R
2‚"R
LARGE DOUBLE VANE ELBOW:USE FOR ELBOWS 36" ORWIDER, AND ANY DEPTH
SMALL DOUBLE VANE ELBOW:USE FOR ELBOWS UP TO 36"IN WIDTH, AND/OR DEPTH
DEP
TH (
D)
2‚"
45°45^
1„"
2„"
45^ 45^
NOTES:
1. ALL SQUARE OR RECTANGULAR ELBOWS SHALL HAVE ONE OF THE TWO TYPES OF TURNING VANES SHOWN ABOVE. SINGLE VANE ELBOWS SHALL NOT BE PERMITTED.
2. CONSTRUCT, SUPPORT, AND FASTEN ALL VANES AS RECOMMENDED BY SMACNA.
3. ALL SQUARE OR RECTANGULAR ELBOWS SHOWN ON PLANS FOR EXHAUST OR RETURN DUCT MAY BE MADE RADIUS ELBOWS, PROVIDED THAT SPACE PERMITS RADIUS INSTALLATION.
4. ALL SQUARE OR RECTANGULAR ELBOWS SHOWN ON PLANS FOR SUPPLY DUCT MAY BE MADE RADIUS ELBOWS, PROVIDED THAT SPACE PERMITS RADIUS INSTALLATION AND/OR THERE IS NO OUTLET OR TAKE-OFF WITHIN 5D ON THE DOWNSTREAM SIDE OF THE ELBOW.
DEP
TH(D
)
3 ‚"
WIDTH (W)
2‚"
1„"MAIN SUPPLY DUCT
BRANCH DUCT
MAIN SUPPLY DUCT
PLAN VIEW
AIR SPLIT TYPE DUCT TAKE-OFF
PLAN VIEW
EXHAUST AND/OR RETURN BRANCH DUCT
PLAN VIEW
SPLIT DIMENSIONPROPORTIONAL
TO AIR FLOW
MAIN RETURNOR EXHAUST
DUCT
BRANCH DUCT(TO ROOM)
BRANCH DUCT(FROM ROOM)
45°
45°W
W
W 4" MIN8" MAX
SUPPLY BRANCH DUCT TAKE-OFF
W 4" MIN8" MAX
SHORT RADIUS ELBOW WITH TWO VANES
SHORT RADIUS ELBOW WITH ONE VANE
STANDARD RADIUS ELBOW
R SHALL BE EQUAL TOOR GREATER THAN W
R
VANE2/3W
R
W
NOTES:
1/3 W
R SHALL BE EQUAL TOOR GREATER THAN 1/6 W
1/6 W
1/2 W
RVANE
R SHALL BE EQUAL TOOR GREATER THAN 1/3 W
W
W
1/3 W
1. MAKE THE INTERIOR SURFACE OF ALL RADIUS ELBOWS ROUND.
2. MAKE ALL STANDARD RADIUS ELBOWS SHOWN ON PLANS SHORT RADIUS ELBOWS. ALL SHORT RADIUS ELBOWS HAVE VANES, AND VANES ARE CONSTRUCTED, SUPPORTED AND FASTENED IN ACCORDANCE WITH SMACNA.
ALL THREAD ROD
NUT (TOP & BOTTOM)
WASHER (TOP & BOTTOM)
CLEVIS HANGER
INSULATION
PIPE
INSULATION PROTECTIVESHEETMETAL SHIELD
CONNECT TO FLOORFRAMING BEAM ABOVEAS REQUIRED
CLEVIS HANGER
1/2" DIA. RODFOR PIPE SIZES2 1/2" AND SMALLER
CLEVIS HANGERGRINNEL FIG. 260
INSULATION SHIELD6" MIN. LENGTH
FLASHING. (PROVIDED BY ROOFING CONTRACTOR. INSTALLED BY ROOFING CONTRACTOR.)
ROOFTHIMBLE
20 GAUGE GALV. STEEL SKIRT.
SEAL WATERTIGHT WITH SILICONE CAULKING COMPOUND.
7"
3/8" MIN. 1/2" MIN.
20 GAUGE GALV.STEEL SKIRT.
45 DEG.
18"
MIN
.
ROOF6"
3"
7"
SIZES INDICATED ON PLANS
6"
INSULATION.
24"
MIN
.
EXHAUST DUCT
ORIENT OUTLET DIRECTION FACING EAST
DECK.
1/2" X 1/2" HARDWIRE MESH BIRDSCREEN
135° GOOSENECK
NOTES:
1. SET, LEVEL, AND SECURE EQUIPMENT TO CURB. PROVIDE ANCHORING/BRACING TO COMPLY WITH WIND RESTRAINT REQUIREMENTS.
2. PROVIDE ROOF OPENING, FRAMING, AND FLASHING.3. ROOFING SHALL BE PERFORMED BY A BONDED
ROOFING CONTRACTOR SUCH AS TO NOT VOID THE EXISTING ROOF WARRANTY.
NOTES:
1. DIMENSION 'H' = FAN INLET PRESSURE (IN. W. C.) + 1".
2. MAXIMUM HEIGHT OF TRAP SHALL BE 1.5 X H.
PITCH DOWNTOWARD DRAIN
CLEAN OUT
H/2
CLEAN OUT
H
UNION
THE DRAIN PIPE SHALL BEAT LEAST THE SAME SIZE
AS THE NIPPLE ON THEDRAIN PAN BUT NO LESS
THAN 1 1/4"
DRAIN PAN
TO NEAREST ROOF OR FLOOR DRAIN
COMBUSTION AIR
ROOF BOOT/ FLASHING (FIELD SUPPLIED)
VENT
VENT
COMBUSTION AIR
ELBOW (FIELD SUPPLIED)
SUPPORT (FIELD SUPPLIED)
NOTE:
SUPPORT MUST BE FIELD INSTALLED TO SECURE TERMINATION KIT TO STRUCTURE.
MAINTAIN 12" MIN. CLEARANCE ABOVE HIGHEST ANTICIPATED SNOW LEVEL. MAXIMUM OF 24" ABOVE ROOF.
14 GA. GALVANIZED BASE &BASE PLATE. END CAPS & SEAMS TO BE CONTINUOUSWELD.
230010 – GENERAL MECHANICAL REQUIREMENTS:A. INSTALL IN ACCORDANCE WITH MANUFACTURER’S INSTRUCTIONS.B. INSTALLATION SHALL COMPLY WITH THE LATEST EDITIONS OF THE MECHANICAL CODE OF NEW YORK STATE, ENERGY CONSERVATION CONSTRUCTION
CODE OF NEW YORK STATE, BUILDING CODE OF NEW YORK STATE, FIRE CODE OF NEW YORK STATE, FUEL GAS CODE OF NEW YORK STATE, AND ALL LOCAL MUNICIPAL CODES.
C. PROVIDE CEILING ACCESS DOORS FOR ALL EQUIPMENT, DAMPERS, ACTUATORS, FIRE DAMPERS, COILS, AND VALVES LOCATED ABOVE INACCESSIBLE CONSTRUCTION.
D. ALL ROOFING WORK SHALL BE PERFORMED BY A BONDING ROOFING SUBCONTRACTOR SUCH AS TO NOT VOID THE ROOF WARRANTY. COORDIANTE ROOF WARRANTY REQUIREMENTS WITH OWNER AND ROOFING MANUFACTURER.
E. SUBMIT SHOP DRAWINGS FOR ALL EQUIPMENT AND MATERIALS PROPOSED. SHOP DRAWING SUBMITTAL SHALL INCLUDE PERFORMANCE CRITERIA, PRESSURE DROPS, ELECTRICAL REQUIREMENTS, CONSTRUCTION INFORMATION, DIMENSIONAL DRAWINGS, WIRING DIAGRAMS, ETC.
F. CONCEAL ALL CONTRACT WORK ABOVE CEILINGS, IN WALLS, BELOW SLABS, AND ELSEWHERE THROUGHOUT THE BUILDING. IF CONCEALMENT IS IMPOSSIBLE OR IMPRACTICAL, WORK SHALL BE INSTALLED PARALLEL TO BUILDING LINES.
G. PROVIDE FIRESTOPPING AT ALL WALL AND FLOOR PENETRATIONS OF FIRE-RATED ASSEMBLIES.H. UNLESS OTHERWISE CALLED FOR, PROVIDE CONCRETE BASES FOR ALL FLOOR-MOUNTED EQUIPMENT AND EQUIPMENT LOCATED AT GRADE. INTERIOR
CONCRETE PADS SHALL BE 3,000 PSI CONCRETE, TROWEL FINISH, CHAMFER EDGES, SECURELY BONDED TO THE FLOOR BY ROUGHENING SLAB AND COATING WITH CEMENT GROUT. EXTERIOR CONCRETE PADS SHALL BE 4,000 PSI CONCRETE, TROWEL FINISH, WITH 6”x6” #6 WELDED WIRE MESH, SET ON 8 IN. DEEP #2 CRUSHED STONE AND COATED WITH CEMENT GROUT. BASES 4 IN. HIGH UNLESS OTHERWISE INDICATED.
I. WATERPROOF SEAL ALL EXTERIOR WALL PENETRATIONS WITH CAULK FILLING SPACE BETWEEN PIPE AND SLEEVES WITH NON-HARDENING CAULKING COMPOUND.
J. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING A COMPLETE AND OPERATIONAL SYSTEM.K. AT SUBSTANTIAL COMPLETION, TURN OVER ALL APPROVED SHOP DRAWINGS, ALL EQUIPMENT OPERATION AND MAINTENANCE MANUALS, AND AS-BUILT
RECORD DRAWINGS, TO THE OWNER.L. INSTALL DUCTWORK TIGHT TO STRUCTURE AND IN LOCATIONS TO AVOID INTERFERENCES.M. DO NOT PENETRATE DUCTWORK WITH PIPING, CONDUIT OR OTHER OBSTRUCTIONS.N. CLEAN ALL RUBBISH, DIRT, DUST AND DEBRIS FROM SYSTEMS BEFORE FANS ARE ACTIVATED. KEEP DUCT OPENINGS CLOSED DURING CONSTRUCTION.
230504 – ELECTRICAL WIRING:A. PROVIDE ALL WIRING AND ACCESSORIES FOR CONTROL OF SYSTEMS AND EQUIPMENT. ALL WIRING INSTALLED EXPOSED IN OCCUPIED SPACES, AND ALL
EXPOSED WITHIN 8’-0” AFF IN UNOCCUPIED MECHANICAL/ELECTRICAL/STORAGE ROOMS, SHALL BE INSTALLED IN A MINIMUM ¾-IN. RIGID METALLIC CONDUIT. HORIZONTAL WIRING CONCEALED ABOVE CEILINGS AND WITHIN MECHANICAL/ELECTRICAL ROOMS SHALL BE SUPPORTED WITH BRIDLE RINGS.
B. PROVIDE 18-IN. FLEXIBLE CONDUIT AT CONNECTIONS TO EQUIPMENT PRONE TO VIBRATION.C. DO NOT ATTACH CONDUIT AND WIRING DIRECTLY TO HOT SURFACES, PIPING OR DUCTWORK.D. CONTROL WIRING SHALL BE INSTALLED IN SEPARATE CONDUIT FROM ALL OTHER WIRING.E. ALL CONTROL WIRING SHALL BE PLENUM RATED TYPE, MEETING THE REQUIREMENTS OF NEC ARTICLE 300.
230593 – TESTING, ADJUSTING AND BALANCING:A. ADJUST AIR HANDLING AND DISTRIBUTION SYSTEMS TO PROVIDE REQUIRED OR DESIGN SUPPLY, RETURN AND OUTSIDE AIR QUANTITIES INDICATED.
MEASURE AIR QUANTITIES AT ALL AIR INLETS AND OUTLETS, AND AT INTAKES AND DISCHARGES OF ALL UNITS. USE VOLUME CONTROL DEVICES TO REGULATE AIR QUANTITIES ONLY TO THE EXTENT THAT ADJUSTMENTS DO NOT CREATE OBJECTIONALBLE AIR MOTION OR SOUND LEVELS. AFFECT VOLUME CONTROL BY DUCT INTERNAL DEVICES SUCH AS DAMPERS. VARY TOTAL SYSTEM AIR QUANTITIES BY ADJUSTMENT OF FAN SPEEDS. VARY BRANCH AIR QUANTITIES BY DAMPER REGULATION. RECORD THE ACTUAL INSTALLED CONDITIONS, AND SUBMIT FOR REVIEW.
B. ALL AIR INLETS AND OUTLETS SHALL BE BALANCED WITHIN 10% OF DESIGN VALUES.
230710 – INSULATION:A. GENERAL:
1. INSULATION, INCLUDING FINISHES AND ADHESIVES, SHALL HAVE A FLAME SPREAD RATING/SMOKE DEVELOPED RATING NO GREATER THAN 25/50.2. ASBESTOS OR ASBESTOS-CONTAINING MATERIALS ARE PROHIBITED.3. INSTALLED INSULATION CONDITIONS SHALL COMPLY WITH THE ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE.4. LOCATE INSULATION AND COVER SEAMS IN THE LEAST VISIBLE LOCATION. EXTEND ALL SURFACES TO PROTECT RAW EDGES, ENDS AND SURFACES
OF INSULATION. DO NOT EXPOSE GLASS FIBER TO THE AIR.5. DUCT INSULATION SHALL BE CONTINUOUS THROUGH HANGERS, SLEEVES, WALLS, CEILINGS OR FLOOR OPENINGS.
B. DUCT INSULATION SCHEDULE:1. SUPPLY DUCTWORK CONCEALED: 1-1/2 IN. THICK FIBERGLASS BLANKET TYPE.2. SUPPLY DUCTWORK EXPOSED: NOT INSULATED.3. EXHAUST AND OUTDOOR VENTILATION DUCTWORK: INSULATED WITH 1-1/2 IN. THICK FIBERGLASS BLANKET TYPE WITHIN 15’-0” OF EXTERIOR
BUILDING ENVELOPE.4. DUCTWORK LOCATED IN ATTIC AN OTHER UNCONDITIONED SPACES: DOUBLE INSULATION THICKNESS AS OTHERWISE CALLED FOR.5. RETURN DUCTWORK: NOT INSULATED.
C. PIPE INSULATION:1. FLEXIBLE ELASTOMERIC: CLOSED CELL FOAM MATERIAL, COMPLYING WITH ASTM C534. ARMAFLEX, K-FLEX OR EQUAL.2. SPLIT FLEXIBLE PIPING LONGITUDINAL JOINTS AND SEAL WITH ADHESIVE. FITTINGS MADE FROM MITER-CUT PIECES PROPERLY SEALED WITH
ADHESIVE.3. PROVIDE PVC JACKETING WHERE EXPOSED OUTDOORS.4. REFRIGERANT SUCTION PIPING: FLEXIBLE ELASTOMERIC INSULATION, MINIMUM 1 IN. THICKNESS.5. REFRIGERANT LIQUID PIPING: FLEXIBLE ELASTOMERIC INSULATION, MINIMUM ½ IN. THICKNESS.6. CONDENSATE DRAIN PIPING: FLEXIBLE ELASTOMERIC INSULATION, MINIMUM ½ IN. THICKNESS.
232010 – PIPING:A. REFRIGERANT PIPING: TYPE L COPPER, HARD TEMPERED, DEOXIDIZED, DEHYDRATED AND SEALED, REFRIGERANT GRADE. REFRIGERANT GRADE WROUGHT
COPPER FITTINGS, LONG RADIUS ELBOWS. FACTORY MADE SUCTION TRAPS. PIPING AND SYSTEM MEETING REQUIREMENTS OF SAFETY CODE FOR MECHANICAL REFRIGERATION, ANSI/ASHRAE 15-1994 AND ASME/ANSI B31.5. FITTINGS BRAZED WITH SILVER BRAZING ALLOY. CLEAN PIPING, PUMP DOWN AND EVACUATE TO 0.1 IN. VACUUM, BREAK WITH DRY NITROGEN AND RE-EVACUATE TO 0.1 IN. AND HOLD FOR FOUR HOURS, THEN CHARGE SYSTEM.
B. CONDENSATE DRAIN PIPING: SCHEDULE 40 PVC, SOCKET TYPE, MEETING ASTM D 2466. SOLVENT-WELDED JOINTS.
233100 – SHEETMETAL AND DUCTWORK ACCESSORIES:A. PROVIDE VOLUME DAMPERS AT ALL AIR OUTLETS, DIFFUSERS, GRILLES, REGISTERS AND WHERE NOTED ON PLANS.B. DUCTWORK SHALL BE CONSTRUCTED FOR A MINIMUM PRESSURE CLASS OF 2 IN. W.C. AND CONSTRUCTED PER SMACNA DUCT CONSTRUCTION
STANDARDS. 20° TRANSITIONS FOR DIVERGING FLOW AND 30° TRANSITIONS FOR CONVERGING FLOW.C. RECTANGULAR DUCTWORK: G-60 GALVANIZED STEEL OR ALUMINUM AS NOTED, GAUGES PER SMACNA DUCT CONSTRUCTION STANDARDS. DUCT
REINFORCEMENT PER SMACNA STANDARDS.D. ROUND DUCTWORK: G-60 GALVANIZED STEEL, SPIRAL CONSTRUCTION WITH LOCKED SEAMS. ALL FITTINGS FABRICATED PER SMACNA STANDARDS,
MATERIAL MATCHING STRAIGHT PIECES OF DUCTWORK, CONTINUOUS WELDED SEAMS.E. FLEXIBLE CONNECTIONS: FIRE RETARDANT, WATER AND MILDEW RESISTANT, COMPLYING WITH UL 214. HEAVY GLASS FABRIC, NEOPRENE COATED, 20 OZ.
PER SQ. YD., MAXIMUM OPERATING TEMPERATURE OF 200 DEG F. DURODYNE, FLEXICRAFT, VENTRABRICS OR UNAFLEX. PROVIDE AT DUCT CONNECTIONS TO FURNACES AND AIR HANDLING UNITS. SECURELY HOLD IN GROOVED SEAM BETWEEN FLANGES, ATTACH WITH ADHESIVE AND MECHANICAL FASTENERS 6 IN. ON CENTER. PROVIDE FLEXIBLE CONNECTION AT SUPPLY AIR DISCHARGE OFF FURNACE DX COIL HOUSING.
F. DUCTWORK SCHEDULE:1. SUPPLY, RETURN, VENT, RELIEF, OUTSIDE AND EXHAUST: LOCK FORMING QUALITY, GALVANIZED STEEL.
233400 – FANS:A. CEILING MOUNTED FANS: GALVANIZED STEEL HOUSING AND REMOVABLE GRILLE, CENTRIFUGAL FORWARD CURVED WHEEL. DIRECT DRIVE MOTOR INSIDE
AIR STREAM, INTEGRAL BACKDRAFT DAMPER AT DISCHARGE COLLAR.B. COOK, GREENHECK, NEW YORK BLOWER, PENN BLOWER, TWIN CITY FANS.
233713 – REGISTERS, GRILLES AND DIFFUSERS:A. LOUVER FACE REGISTER: STEEL CONSTRUCTION, DOUBLE DEFLECTION WITH TWO SETS OF ADJUSTABLE BLADES ¾-IN. ON CENTER, FRONT BLADES
RUNNING PARALLEL TO THE SHORT DIMENSION, INTEGRAL OPPSED-BLADE VOLUME DAMPER, SPONGE RUBBER GASKET, BAKED-ON POWDER COAT FINISH. ANEMOSTAT, CARNES, KRUEGER, NAILOR, PRICE, TITUS, TUTTLE AND BAILEY.
B. LOUVER FACE GRILLE: STEEL CONSTRUCTION, SINGLE DEFLECTION WITH BLADES ¾-IN. ON CENTER PARALLEL TO THE LONG DIMENSION, SPONGE RUBBER GASKET, BAKED-ON POWDER COAT FINISH. ANEMOSTAT, CARNES, KRUEGER, NAILOR, PRICE, TITUS, TUTTLE AND BAILEY. PROVIDE 12 IN. DEEP PLENUM BOX FOR ALL CEILING APPLICATIONS, PAINT INSIDE FLAT BLACK.
233800 - VENTILATION HOODS:A. CONICAL COLLECTION HOOD: 0.063 GAGE ALUMINIM, ALLOY 1100-0B. BLOWER: MAX CONTINUNOUS TEMPERATURE RATING OF 250°FC. FLEXIBLE EXHAUST HOSE/DUCT: TRIPLE PLY LAMINATE, ALUMINIZED POLYESTER FACE AND ALUMINUM FOIL BACKING. CORROSION, MOISTURE, AND FLAME
RESISTANT. UL 723 LISTED. CUT TO SHORTEST LENGTH PERMISSABLE. D. EXTERIOR SURFACE MOUNTED LOUVER: BIRD SCREEN, THREE (3) GRAVITY OPERATED SHUTTERS.E. CABLE: 3/16" PLASTIC COATED STEEL CABLE, TWO (2) 3/16" GALVANIZED STEEL CABLE CLAMPS TO FASTEN COUNTERWIEGHT AND BLOWER.F. OVERHEAD PULLEY SYSTEM: 24" L STRUCTURAL TUBING, TWO (2) BALL BEARING PULLEYS WITH SAFETY STRAPS, ONE (1) RESISTANCE PULLEY, TWO (2)
HANGING SLIDE BRACKETS.
235416 – CONDENSING GAS-FIRED FURNACES:A. PROVIDE 10 YEAR HEAT EXCHANGER WARRANTY.B. CABINET:
1. CONSTRUCTED OF GALVANIZED STEEL WITH FACTORY INSTALLED FOIL FACE INSULATION AND POWDER COAT FINISH.2. SURFACES IN CONTACT WITH AIRSTREAM SHALL COMPLY WITH ASHRAE 62.1.3. HORIZONTAL CONFIGURATION, REAR RETURN AIR INLET, END SUPPLY AIR DISCHARGE.
C. FAN:1. MULTI-TAPPED, MULTI-SPEED MOTOR.2. INTERNAL THERMAL PROTECTION AND PERMANENT LUBRICATION.
E. BURNER:1. 100 PERCENT SAFETY TWO-STAGE GAS VALVE, MAIN SHUTOFF VALVE, PRESSURE REGULATOR, SAFETY PILOT WITH ELECTRONIC FLAME SENSOR,
LIMIT CONTROL, TRANSFORMER, COMBINATION IGNITION/FAN TIMER CONTROL BOARD.2. ELECTRIC PILOT IGNITION WITH HOT SURFACE IGNITER OR ELECTRIC SPARK IGNITION.3. ELECTRONIC FLAME SENSOR, FLAME ROLLOUT SWITCH, LIMIT CONTROL.4. COMBUSTION AIR INDUCER FAN WITH THERMALLY PROTECTED MOTOR AND SLEEVE BEARINGS.
F. COOLING COIL:1. DIRECT EXPANSION A-COIL, WITH GALVANIZED STEEL CASING AND POWDER COAT FINISH.2. CORROSION RESISTANT ALUMINUM COIL.3. SLOPED CORROSION-FREE DRAIN PAN WITH DRAIN CONNECTION.4. THERMOSTATIC EXPANSION VALVE (TXV).
G. ACCESSORIES:1. COMBINATION CONCENTRIC VENT KIT, PVC PLASTIC FITTINGS TO COMBINE COMBUSTION AIR INLET AND VENT THROUGH ROOF. 2. VENT MATERIAL: SCHEDULE 40 PVC, SOCKET TYPE FITTINGS WITH SOLVENT CEMENT.3. TWO-STAGE HEATING AND COOLING THERMOSTAT, WALL MOUNTED, 7-DAY PROGRAMMABLE. PROVIDE LOCKABLE ACRYLIC GUARD COVER.4. FILTERS: 4-IN. DISPOSABLE FIBERGLASS, MERV 11.5. CONDENSATE LIFT PUMP: INSTALL PER MANUFACTURER'S RECOMMENDATIONS
H. BRYANT, CARRIER, DAIKIN COMFORT, GOODMAN, LENNOX, TRANE, YORK.I. SUPPORT UNITS FROM STRUCTURE WITH UNISTRUT AND THREADED ROD. MAKE ALL FINAL VENTING, DUCTWORK, GAS PIPING, CONDENSATE DRAIN PIPING, REFRIGERANT PIPING AND CONTROL WIRING FOR A COMPLETE AND OPERABLE SYSTEM, IN ACCORDANCE WITH NFPA 54. ADJUST HANGERS SO UNIT IS LEVEL AND PLUMB. INSTALL THERMOSTAT ON WALL AT 48 IN. AFF WITH LOCKABLE ACRYLIC GUARD COVER. ROUTE CONTROL WIRING WITHIN WALL CAVITY.
236200 – AIR-COOLED CONDENSING UNITS:A. 10 YEAR COMPRESSOR WARRANTY.B. SHALL MEET ENERGY STAR REQUIREMENTS.C. HEAVY GAUGE STEEL HOUSING WITH BAKED ON POWDER COAT FINISH, STEEL LOUVERED COIL GUARD.D. TWO-STAGE SCROLL COMPRESSOR.E. SYSTEM PROTECTING HIGH AND LOW PRESSURE SWITCHES.F. FILTER DRYER.G. BRYANT, CARRIER, DAIKIN COMFORT, GOODMAN, LENNOX, TRANE, YORK.H. SET, LEVEL AND SECURE TO EQUIPMENT RAILS. CONNECT REFRIGERANT PIPING, CHARGE SYSTEM.
Revisions
NO: DATE: DESCRIPTION:
GENERAL LINEWORK DESCRIPTIONS & DRAWINGS NOTES
NEW WORK
EXISTING WORK / FUTURE PROVISIONS / NOT IN CONTRACT WORK
WORK TO BE REMOVED (DEMO PLANS) - DEVICE AND ALL ASSOCIATED ELECTRICAL WORK SHALL BE REMOVED BACK TO THE SOURCE, UNLESS NOTED OTHERWISE / UNDERFLOOR CONDUIT (NEW PLANS)
WIRE AND / OR CONDUIT RUN CONTINUED ON REFERENCED DETAIL
MATCH LINE REFERENCING CONTINUATION ON OTHER DRAWING
CALLOUT BOUNDARY - DETAIL AND / OR SECTION REFERENCE / SCOPE OF WORK
BRANCH CIRCUIT BOUNDARY
DRAWING KEYED NOTES
BRANCH CIRCUITING NOTES
FEEDER IDENTIFICATION
KITCHEN / LAB EQUIPMENT TAG
SYMBOL WITH TAIL INDICATES WALL INSTALLATION, HEIGHT AS INDICATED
INDICATES MULTIPLE DEVICES OF DIFFERENT TYPES INSTALLED UNDER COMMON COVERPLATE AT ONE LOCATION (DEVICES SHALL BE INSTALLED UNDER A COMMON COVERPLATE)
CIRCUIT NUMBER(S)11,131LNL1
BRANCH CIRCUIT CONDUCTOR SIZING
CONDUCTOR SIZE (AWG)
NOTES:
1.
2.
3.
4.
90MAXIMUM BRANCH CIRCUIT LENGTH AT 120V (FEET)
MAXIMUM BRANCH CIRCUIT LENGTH AT 277V (FEET)
140 225
205 325 520
#12 #10 #8
INCREASE ALL BRANCH CIRCUIT CONDUCTORS AS INDICATED BASED ON LENGTH OF CIRCUIT, INCLUDING EQUIPMENT GROUNDING CONDUCTOR.
TRANSITION FROM LARGER CONDUCTOR SIZE TO #12 AWG FOR FINAL TERMINATION TO OUTLET DEVICE. PROVIDE JUNCTION BOX WITHIN 10' OF OUTLET AND EXTEND #12 AWG CONDUCTORS TO OUTLET.
LENGTHS ARE FROM OVERCURRENT PROTECTIVE DEVICE, ALONG CIRCUIT ROUTING, TO CENTER OF EQUIPMENT LOAD.
SCHEDULE ASSUMES 12A LOAD, FOR LOADS HIGHER THAN 12A, INCREASE CONDUCTOR SIZE.
CIRCUIT NOTATION:
20A BRANCH CIRCUIT CONDUCTOR SIZING SCHEDULE:
355
825
#6
565
1310
#4
PROVIDE MINIMUM WIRE SIZE AS FOLLOWED UNLESS NOTED OTHERWISE:20A CB - #12 AWG30A CB - #10 AWG40A CB - #8 AWG50A CB - #6 AWGINCREASE SIZE OF CONDUCTOR FOR DISTANCE AS SHOWN BELOW IN 20A BRANCH CIRCUIT CONDUCTOR SIZING SCHEDULE.
SOURCE PANELBOARD (IF OTHER THAN NOTED ON SHEET/CIRCUIT BOUNDARY)
#
#
#
#
FILL (DESIGNATES BRANCH TYPE):
NORMAL BRANCH PANELBOARD
PANELBOARDS
DEVICE SUBSCRIPTS
II ROMAN NUMERAL INDICATES QUANTITY OF GANGED DEVICES UNDER COMMON FACEPLATE+xx HEIGHT OF DEVICE ABOVE FINISHED FLOOR (IN INCHES)a LOWER CASE LETTER(S) INDICATES SWITCH CONTROL ARRANGEMENT5 NUMERAL INDICATES BRANCH CIRCUIT NUMBER (POWER & LIGHTING)/CANDELA RATING (FIRE ALARM DEVICES)D DIMMER SWITCH (LIGHTING CONTROL)ERL EXISTING TO BE RELOCATEDETR EXISTING TO REMAINFB INSTALL IN FLOORBOX/POKETHRULV LOW VOLTAGEO OCCUPANCY SENSOR (AUTOMATIC 'ON' LIGHTING SENSOR SWITCH)V VACANCY SENSOR (MANUAL 'ON' LIGHTING SENSOR SWITCH)W INSTALL 44" AFF
LIGHTING
GEOMETRIC SHAPE LUMINAIRE, RECESSED OR SURFACE MOUNTED PER LUMINAIRE SCHEDULE
ILLUMINATED EXIT SIGN - SINGLE/DOUBLE FACE AS SHOWN - DIRECTION OF ARROWS AS INDICATED - CEILING, SURFACE WALL, OR PERPENDICULAR WALL AS SHOWN
PROXIMITY ACCESS CARD READER, 44" AFF, 4" FROM DOOR FRAME
RECESSED DOOR CONTACT SWITCH, COORDINATE WITH DOOR FRAME INSTALLER
CONNECTION TO ALARM NOTIFICATION, SECURITY OVERRIDE DEVICE
CONNECTION TO DOOR ELECTRIC STRIKE
SECURITY DEVICES & ACCESS CONTROL
NOTE: PROVIDE CONDUIT FROM BOX STUBBED INTO ACCESSIBLE CEILING SPACE IN NEAREST CORRIDOR AND CAT6 BACK TO PATCH PANEL.
DATA/TELECOMMUNICATIONS OUTLET, 2 PORTS WITH 2 CABLES, 18" AFF
DATA/TELECOMMUNICATION OUTLETS
a
CIRCUIT #
SWITCHLEG CONTROL ARRANGEMENT15
1LNL1SOURCE PANELBOARD(IF OTHER THAN NOTED ON SHEET/CIRCUIT BOUNDARY)
GENERAL LUMINAIRE NOTATION:
LD1
LUMINAIRE TYPE - REFER TO LUMINAIRE SCHEDULE
POLE TYPE - REFER TO SITE LIGHTING POLE SCHEDULE/LUMINAIRE SCHEDULE
P-A
DOTS INDICATE PENDANT HUNG
TAIL INDICATES WALL MOUNT STYLE LUMINAIRE
CR
DC
ES
SOD
FIRE ALARM, GAS DETECTION, & MASS NOTIFICATION DEVICES
SMOKE DETECTOR, CEILING MOUNTED
FIRE ALARM HORN/STROBE, 90 dB, WALL MOUNTED, MIN 80"/ MAX 96" AFF (# INDICATES CANDELA RATING)
FIRE ALARM STROBE LIGHT, WALL MOUNTED, MIN 80"/ MAX 96" AFF (# INDICATES CANDELA RATING)
FIRE ALARM MANUAL PULL STATION, 44" AFF UNLESS NOTED OTHERWISE
GAS DETECTOR, WALL MOUNTED (CO = CARBON MONOXIDE 60" AFF, NG = NATURAL GAS 18" BELOW CEILING)
MASS NOTIFICATION HORN/STROBE, 90dB, 75cd STROBE INTENSITY UNLESS OTHERWISE NOTED, WALL MOUNTED 18" BELOW CEILING - CO = CARBON MONOXIDE; WHITE HOUSING, RED LENS, 'CO ALARM' LABELING
75
F
R4 RELAY DESIGNATION (IF APPLICABLE)
LIGHTING CONTROL DEVICES
SINGLE POLE TOGGLE SWITCH, 44" AFF
3-WAY TOGGLE SWITCH, 44" AFF
DIMMING SWITCH, SINGLE OR MULTIPLE LOCATION FUNCTIONALITY AS SHOWN, 44" AFF
NOTE: LIGHTING CONTROL DEVICES SHOW FUNCTIONAL REQUIREMENTS, NOT ALL DEVICES NEEDED FOR A FULLY FUNCTIONING SYSTEM. DEPENDING ON CONFIGURATION AND MANUFACTURER, DEVICES SUCH AS POWER PACKS, RELAYS, SINGLE/DOUBLE/TRIPLE
OUTPUT ROOM CONTROLLERS MAY BE NECESSARY. REFER TO DETAILS & SPECIFICATIONS.
ELECTRICAL DEVICES
NEMA 5-20R DUPLEX RECEPTACLE, 18" AFF
NEMA 5-20R DUPLEX RECEPTACLE, INSTALLED FLUSH IN CEILING
NEMA 5-20R GFCI DUPLEX RECEPTACLE, 18" AFF
NEMA 5-20R QUADPLEX (DOUBLE DUPLEX) RECEPTACLE, 18" AFF
NEMA 5-20R GFCI QUADPLEX (GFCI REC W/ DUPLEX ON LOAD SIDE UNDER COMMON COVERPLATE) RECEPTACLE, 18" AFF
NEMA CONFIGURATION TO MATCH INDICATED EQUIPMENT OR AS CALLED OUT, 18" AFF
START/STOP PUSHBUTTONS, 54" AFFS/S
+30"PI
CIRCUIT #INSTALLATION HEIGHT TO CENTER OF DEVICE IN INCHES (IF OTHER THAN SPECIFIED ON LEGEND)
SUBSCRIPT (IF APPLICABLE)
GENERAL ELECTRICAL DEVICE NOTATION:
15
1LNL1
SOURCE PANELBOARD (IF OTHER THAN NOTED ON SHEET/CIRCUIT BOUNDARY)
RACEWAY, BOXES, & BUSWAY
JUNCTION BOX, HEIGHT AS INDICATED
MULTISERVICE BOX, # INDICATES DESIGNATION, SEE MULTISERVICE BOX SCHEDULE
J
MSB1
EQUIPMENT CONNECTIONS
DIRECT CONNECTION FOR 120V EQUIPMENT CONNECTED TO NORMAL BRANCH
SINGLE PHASE MOTOR/PUMP CONNECTION, REFER TO EQUIPMENT CONNECTION SCHEDULE
THREE PHASE MOTOR/PUMP CONNECTION, REFER TO EQUIPMENT CONNECTION SCHEDULE
SINGLE POINT EQUIPMENT CONNECTION, REFER TO EQUIPMENT CONNECTION SCHEDULE
NDEGREESDELTAOHMSPHASEWYE
AMPEREARC-FAULT CIRCUIT INTERRUPTINGABOVE FINISHED FLOORAUTHORITY HAVING JURISDICTIONAIR HANDLING UNITAMPERE INTERRUPTING CAPACITYALUMINUMANNUNCIATORAUTOMATIC TRANSFER SWITCHAUDIO VISUALAVERAGEAMERICAN WIRE GAUGE
LOCAL AREA NETWORKLIQUID CRYSTAL DISPLAYLIGHT EMITTING DIODELIGHTING LOW VOLTAGE
ABBREVIATIONS
MAGMAXMCBMDPMECHMFRMICMINMLOMOCP
NANECNEMANFPANICNLNOMNTS
OCOCPDODOF/CIOF/OIOH
PPAPBPCPHPOEPRIPTPTZPVC
RCPRECREFRFIDRMRMC
SCHEDSECSFSFLSMSPDSPDTSPSTSPECSTPSWBDSWGR
TELTGBTHDTMGBTVTYP
UGNDULUNOUPSUTP
VVAVACVDCVFDVENDVSDVOlP
WWPWR
XFMR
°∆ΩØY
AAFCIAFFAHJAHUAICALUMANNATSAVAVGAWG
BASBLDG
CNDCATCBCKTCLGCOCOAXCTCU
DCDIADIVDPDTDPSTDWG
EAEFEGCELECEMTEOLEQUIPEWC
FAFAAPFACPFATCFCFLRFTL
GECGENGFCIGFIG
HOAHPHTRHVHZ
IDIPIR
J-BOX
kAICkAIRkVkVAkWkWh
LANLCDLEDLTGLV
MAGNETICMAXIMUMMAIN CIRCUIT BREAKERMAIN DISTRIBUTION PANELBOARDMECHANICALMANUFACTURERMICROPHONEMINIMUMMAIN LUGS ONLYMAXIMUM OVERCURRENT PROTECTION
NOT APPLICABLENATIONAL ELECTRICAL CODENATIONAL ELECTRICAL MANUFACTURERS ASSOCIATIONNATIONAL FIRE PROTECTION ASSOCIATIONNOT IN CONTRACTNIGHT LIGHTNOMINALNOT TO SCALE
ON CENTEROVERCURRENT PROTECTIVE DEVICEOUTSIDE DIAMETEROWNER FURNISHED/CONTRACTOR INSTALLEDOWNER FURNISHED/OWNER INSTALLEDOVERHEAD
POLEPUBLIC ADDRESSPULLBOXPERSONAL COMPUTERPHASEPOWER OVER ETHERNETPRIMARYPOTENTIAL TRANSFORMERPAN TILT ZOOMPOLYVINYL CHLORIDE
REFLECTED CEILING PLANSRECEPTACLEREFRIGERATORRADIO FREQUENCY IDENTIFICATION DEVICEROOMRIGID METAL CONDUIT
SCHEDULESECONDARYSUPPLY FANSUB FEED LUGSSINGLE MODESURGE PROTECTIVE DEVICESINGLE POLE DOUBLE THROWSINGLE POLE SINGLE THROWSPECIFICATIONSHIELDED TWISTED PAIRSWITCHBOARDSWITCHGEAR
TELEPHONETELECOMMUNICATIONS GROUNDING BUS BARTOTAL HARMONIC DISTORTIONTELECOMMUNICATIONS MAIN GROUNDING BUS BARTELEVISIONTYPICAL
UNDERGROUNDUNDERWRITERS LABORATORIESUNLESS NOTED OTHERWISEUNINTERRUPTIBLE POWER SUPPLYUNSHIELDED TWISTED PAIR
VOLTVOLT-AMPEREVOLTS ALTERNATING CURRENTVOLTS DIRECT CURRENTVARIABLE FREQUENCY DRIVEVENDING MACHINEVARIABLE SPEED DRIVEVOICE OVER INTERNET PROTOCOL
WATTWEATHERPROOFWEATHER RESISTANT
TRANSFORMER
ELECTRICAL GENERAL NOTES
FOR EXACT LOCATIONS AND SURFACE FINISH CONDITIONS OF CEILINGS, WALLS, OR FLOORS, REFER TO ARCHITECTURAL DRAWINGS.
FOR EXACT LOCATION OF FACILITY EXPANSION JOINTS, FIRE RATED WALLS, AND SMOKE WALLS, REFER TO ARCHITECTURAL DRAWINGS.
VERIFY EXACT LOCATION OF CONNECTION POINTS PRIOR TO ROUGH-IN.
COORDINATE LOCATIONS OF ALL RECEPTACLES AND LUMINAIRES IN MECHANICAL SPACES WITH HVAC CONTRACTOR PRIOR TO ROUGH-IN TO AVOID CONFLICTS WITH EQUIPMENT AND DUCTWORK.
MOUNTING HEIGHTS ARE TO CENTER OF DEVICE OR EQUIPMENT UNLESS NOTED OTHERWISE, EXCEPT FOR PENDANT LIGHTING WHICH ARE TO THE BOTTOM OF THE LUMINAIRE. FOR AREAS WITH DIFFERENT FLOOR LEVELS, HEIGHT IS BASED UPON CLOSEST FLOOR OR LANDING TO DEVICE, EQUIPMENT, OR LUMINAIRE. ELEVATIONS GIVEN ON LEGEND SHEET ARE UNLESS NOTED OTHERWISE ON DRAWINGS.
PROVIDE RACEWAY, WIRE AND CABLE, ASSOCIATED FITTINGS AND CONNECTORS, AND COMPLETE CONNECTIONS REQUIRED FOR DESIGNATED BRANCH CIRCUITS FROM DEVICE(S) TO FINAL OVERCURRENT DEVICE AND TO LOCAL CONTROL DEVICE(S) PER SPECIFICATIONS.
MINIMUM BRANCH CIRCUIT WIRE SIZE SHALL BE #12 AWG. SIZE BRANCH CIRCUIT CONDUCTORS AS PER NEC AND AS SCHEDULED ON THIS DRAWING BASED ON ACTUAL CIRCUIT DISTANCE. INCLUDE GROUND CONDUCTOR DERATINGS.
PROVIDE A SEPARATE NEUTRAL CONDUCTOR FOR ALL BRANCH CIRCUITS REQUIRING A NEUTRAL CONNECTION. DERATE CONDUCTORS PER NEC ACCORDINGLY. MULTIWIRE BRANCH CIRCUITS ARE NOT ACCEPTABLE.
PROVIDE GROUNDING PER NEC & TIA 607B. PROVIDE GREEN GROUND CONDUCTOR IN ALL BRANCH AND FEEDER CIRCUITS.
DO NOT INSTALL ANY NEW WORK DIRECTLY ABOVE ANY ELECTRICAL PANELS, SWITCHBOARDS, SWITCHGEAR, OR TRANSFORMERS.
CIRCUIT NUMBERS SHOWN FOR EQUIPMENT TO BE CONNECTED TO EXISTING PANELBOARD(S) IS SHOWN FOR DESIGN INTENT ONLY AND MAY NOT CORRESPOND TO ACTUAL CIRCUIT BREAKER MOUNTING POSITION IN THE PANEL. UPDATE THE RECORD DRAWINGS & PANELBOARD DIRECTORY WITH THE ACTUAL CIRCUIT NUMBERS USED TO CORRESPOND TO THE PANEL DIRECTORY.
CONFIRM ALL LABELS AND ROOM NUMBERS WITH OWNER PRIOR TO FINALIZING LABELING AND PROGRAMMING.
COORDINATE FINAL OUTLET LOCATION WITH ALL TRADES AND FURNITURE/MILLWORK PLACEMENT PRIOR TO ROUGH-IN. GENERAL CONTRACTOR SHALL PROVIDE ALL DRILLING AND GROMMETING IN FURNITURE/CASEWORK FOR CORD ACCESS IF REQUIRED.
INSTALL DATA OUTLETS 6" ADJACENT TO ASSOCIATED ELECTRICAL OUTLET.
SWITCHES SHOWN SIDE BY SIDE OR GANGED SHALL BE INSTALLED UNDER A COMMON COVERPLATE, UNLESS NOTED OTHERWISE.
PROVIDE FIRESTOPPING AT ALL PENETRATIONS THROUGH FIRE RATED WALLS, FLOORS, CEILINGS, & ROOFS AS CALLED OUT ON ARCHITECTURAL PLANS. PROVIDE ACOUSTICAL SEALANT AT PENETRATIONS THROUGH ALL NON-FIRE RATED WALLS, FLOORS, & CEILINGS.
PROVIDE CONDUIT EXPANSION JOINTS AT ALL EXPANSION JOINTS AS CALLED OUT ON ARCHITECTURAL PLANS.
SITE PLAN CONDUIT ROUTING SHOWN FOR INTENT. REFERENCE CIVIL DRAWINGS FOR UNDERGROUND COORDINATION AND DISTANCE OF RUNS. COORDINATE WITH ALL TRADES.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
ELECTRICAL DEMOLITION GENERAL NOTES
REMOVE ALL ELECTRICAL EQUIPMENT ON OR IN EXISTING WALLS, CEILINGS AND PARTITIONS WHICH ARE TO BE DEMOLISHED. WHERE EQUIPMENT IS SCHEDULED TO BE REMOVED, ABANDON CONCEALED RACEWAY AND REMOVE CONDUCTORS BACK TO SOURCE OR LAST SCHEDULED DEVICE TO REMAIN. REMOVE EXPOSED RACEWAY AND CONDUCTORS BACK TO POWER SOURCE OR LAST DEVICE SCHEDULED TO REMAIN IN ALL OTHER AREAS.
WHERE EXISTING WALLS ARE TO REMAIN, REMOVE ALL EXPOSED RACEWAYS, SURFACE AND RECESSED OUTLET BOXES, ETC. WHICH ARE NOT TO BE REUSED. WHERE NEW CONDUITS AND OUTLETS ARE TO BE ADDED TO EXISTING WALLS IN FINISHED ROOMS, THEY SHALL BE CONCEALED BY CUTTING AND PATCHING THE WALLS UNLESS OTHERWISE NOTED.
UTILIZE EXISTING OUTLET BOXES AND RACEWAY SYSTEMS WHEREVER PRACTICAL IN RENOVATION AREAS. WHERE SUCH EXISTING OUTLET BOXES ARE USED, INSTALL NEW WIRING DEVICES, COVERPLATES, AND WIRING. PROVIDE SPECIAL COVERPLATES TO SUIT FIELD CONDITIONS.
REARRANGE EXISTING CONDUITS AND WIRING TO ACCOMMODATE NEW CIRCUIT ARRANGEMENTS INDICATED AND TO MAINTAIN CONTINUITY OF EXISTING CIRCUITS FEEDING DEVICES THAT ARE TO REMAIN.
CONTRACTOR SHALL BE RESPONSIBLE TO REMOVE AND REINSTALL EXISTING ELECTRICAL EQUIPMENT TO ACCOMMODATE THE WORK OF OR DISTURBED BY ALL TRADES.
PROVIDE DISPOSAL FROM SITE AT CONTRACTORS EXPENSE IN ACCORDANCE WITH APPLICABLE LAWS AND REGULATIONS THAT THE OWNER DOES NOT WISH TO SALVAGE.
EXISTING DEVICE LOCATIONS WERE IDENTIFIED AS COMPLETELY AS POSSIBLE BY A SITE SURVEY AND BY RECORD DOCUMENTS AS AVAILABLE. BE RESPONSIBLE FOR PROPER DEMOLITION AND REWORK OF DEVICES NOT SHOWN ON DRAWINGS BUT NECESSARY FOR PROJECT RENOVATIONS TO CONFORM WITH INTENT OF DOCUMENTS. VISIT THE SITE TO DETERMINE THE EXACT EXTENT OF ELECTRICAL DEMOLITION WORK REQUIRED TO COMPLETE THE NEW CONSTRUCTION. CONTRACTOR SHALL PROVIDE IN BASE BID A NOMINAL AMOUNT OF UNKNOWN BRANCH CIRCUITS, FIXTURES, DEVICES, AND SYSTEMS WIRING BEING REMOVED OR RELOCATED FOR NEW WORK.
WHERE DEMOLITION OF DEVICE OR EQUIPMENT AND REMOVAL OF CONDUIT OR OTHER ACCESSORY LEAVES OPENINGS IN THE FLOORS, WALLS, OR CEILINGS, SAME SHALL BE PATCHED AND PAINTED TO MATCH EXISTING ADJACENT FINISH. ALL OPENINGS IN FLOORS SHALL BE PINNED WITH REBAR.
REFER TO DEMOLITION DRAWINGS & NOTES OF ALL CONTRACTS OR TRADES FOR COORDINATION.
IN AREAS OF DEMOLITION WHERE THE REMOVAL OF ELECTRICAL EQUIPMENT INTERFERES WITH THE NORMAL BUILDING OPERATIONS AND SYSTEMS, CONSULT WITH THE OWNER PRIOR TO PERFORMING ANY DEMOLITION.
WHERE UNFORESEEN CONDITIONS CONFLICT WITH CONTRACT DOCUMENTS, SUBMIT AN RFI PRIOR TO PROCEEDING WITH ANY WORK.
WHERE DEVICES ARE SCHEDULED FOR RELOCATION, DISCONNECT AND REMOVE EXISTING DEVICE AND REMOVE ASSOCIATED WIRING. RELOCATE DEVICE AS SHOWN, EXTEND WIRING AS REQUIRED, AND MATCH EXISTING.
WHERE REMOVALS AFFECT EXISTING CIRCUITS SCHEDULED TO REMAIN, MAINTAIN CONTINUITY OF POWER TO THESE CIRCUITS AND EXTEND WIRING AS NEEDED.
WHERE ANY EMPTY BACKBOXES OR EMPTY JUNCTION BOXES REMAIN DUE TO ELECTRICAL DEMOLITION, PROVIDE COVERPLATE(S) OVER EXISTING BOX(ES).
WHERE EQUIPMENT CONNECTIONS ARE SHOWN, REMOVE ELECTRICAL CONNECTION, CONDUIT AND WIRE BACK TO POWER SOURCE. DISCONNECT AND REMOVE ASSOCIATED CONTROLLER SERVING EQUIPMENT AND ASSOCIATED CONTROL WIRING.
DISCONNECT AND REMOVE EXISTING ELECTRIC WORK NOT NECESSARY FOR EXISTING OR NEW INSTALLATION, BUT INTERFERING WITH NEW CONSTRUCTION.
DISCONNECT, REMOVE, RELOCATE, AND RECONNECT ANY AND ALL EXISTING ELECTRIC WORK REQUIRED TO REMAIN, BUT INTERFERING WITH NEW CONSTRUCTION.
WHERE DEMOLITION NOTES SCHEDULE EXISTING WIRING DEVICES, LIGHTING FIXTURES, SYSTEMS DEVICES, EQUIPMENT CONNECTIONS, ETC. TO BE "DISCONNECTED AND REMOVED IN THE ENTIRETY", THE CONTRACTOR SHALL DISCONNECT AND REMOVE THE EXISTING LIGHTING FIXTURE, WIRING DEVICES, COVERPLATES, BRANCH CIRCUIT WIRING, CONDUIT OR RACEWAY, OUTLET AND/OR SPLICE BOX(ES) ETC. BACK TO EITHER LAST DEVICE SCHEDULED TO REMAIN, OR BACK TO POWER SOURCE.
PROPERLY DISPOSE OF ALL PCB CONTAINING FLUORESCENT BALLASTS MANUFACTURED PRIOR TO 1980 ACCORDING TO STATE AND FEDERAL REGULATIONS.
IF ADDITIONAL SUSPECT ASBESTOS-CONTAINING MATERIALS ARE DISCOVERED DURING THE COURSE OF THE WORK, THE CONTRACTOR SHALL IMMEDIATELY STOP WORK AND NOTIFY THE OWNER AND ARCHITECT IMMEDIATELY. THE CONTRACTOR SHALL COOPERATE WITH THE OWNER AND ARCHITECT TO WITH REGARD TO CONDUCTING ADDITIONAL BULK SAMPLING AND ABATEMENT AT THE OWNER'S EXPENSE.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
TS
OS
185
CO
CO
500 East Sixth StreetJamestown, NY 14701716-483-3153
labellapc.com
DRAWING NAME:
It is a violation of New York Education Law Article 145 Sec.7209, for any person, unless
acting under the direction of a licensed architect, professional engineer, or land
surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or
land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the
item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the
1. THIS CONTRACTOR MUST INSPECT THE EXISTING FIELD CONDITIONS AT THE SITE AND CONTRACT DOCUMENTS PRIOR TO THE START OF ANY WORK TO DETERMINE WHAT EFFECT THE EXISTING CONDITIONS WILL HAVE IN THE WORK. POTENTIAL PROBLEM AREAS MUST BE BROUGHT TO THE ATTENTION OF THE ENGINEER IMMEDIATELY.
2. THIS CONTRACTOR MUST CONNECT THE WORK TO VARIOUS EXISTING ELECTRICAL SYSTEMS. THE NEW WORK IS TO BE COMPATIBLE WITH THE EXISTING SYSTEM CONDITIONS.A. LOCATION OF EQUIPMENT OR THE ROUTING OF THE VARIOUS SYSTEMS MUST BE GOVERNED BY EXISTING CONDITIONS AS THEY APPEAR IN THE FIELD OR ON THE DRAWINGS. ALL CORING MUST
BE COORDINATED WITH THE BUILDING OWNER.B. CARE MUST BE TAKEN DURING THE INSTALLATION OF THE NEW WORK NOT TO DAMAGE OR INTERRUPT THE EXISTING SYSTEMS AND SERVICES INSTALLED. DAMAGE TO EXISTING SYSTEMS AND
EQUIPMENT CAUSED BY THIS CONTRACTOR DURING THE INSTALLATION OF THE WORK MUST BE REPAIRED AND/OR REPLACED AT THIS CONTRACTOR'S EXPENSE TO THE COMPLETE SATISFACTION OF THE OWNER.
C. SHUTDOWN OF EXISTING SYSTEMS FOR CONNECTIONS TO EXISTING SERVICES IS TO BE COORDINATED WITH THE OWNER.
3. THE SCOPE OF WORK UNDER THIS SECTION INCLUDES THE FURNISHING OF ALL LABOR, MATERIALS, EQUIPMENT, SERVICES AND INCIDENTALS NECESSARY TO COMPLETE ALL ELECTRICAL WORK IN ACCORDANCE WITH THE INTENT OF THE SPECIFICATIONS AND THE DRAWINGS.
4. ALL WORK MUST BE INSTALLED IN CONFORMANCE TO OWNER REQUIREMENTS, THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE AND ALL OTHER FEDERAL, STATE AND LOCAL REGULATIONS AND ORDINANCES. THESE REQUIREMENTS ARE MINIMUM CRITERIA AND NO REDUCTION IN STANDARDS CALLED FOR ON THE DRAWINGS, PERMITTED BY CODE, IS ALLOWED.
5. OBTAIN AND PAY FOR ALL INSPECTIONS, LICENSES, PERMITS AND APPROVALS REQUIRED BY GOVERNING AUTHORITIES AND INSTALL ALL WORK IN COMPLIANCE THEREOF. INCLUDE IN BID, ALL APPLICABLE TAXES AND PREMIUMS OF INSURANCE REQUIRED BY THE GENERAL CONDITIONS OF THE CONTRACT.
6. ELECTRICAL EQUIPMENT IS TO BE MOUNTED AT THE FOLLOWING HEIGHTS UNLESS OTHERWISE NOTED OR DETAILED ON THE ELECTRICAL DRAWINGS. IF THE MOUNTING HEIGHT OF ANY ELECTRICAL COMPONENT IS QUESTIONABLE, OBTAIN CLARIFICATION FROM THE ENGINEER BEFORE INSTALLATION.A. LIGHT SWITCHES, PUSHBUTTON STATIONS, HOA SWITCHES, SELECTOR SWITCHES, AND ALL OTHER TOGGLE OR CONTROL SWITCHES -- 44" ABOVE FINISHED FLOOR TO CENTERLINE.B. WALL MOUNTED RECEPTACLES - 18 INCHES ABOVE FINISHED FLOOR TO CENTERLINE IN FINISHED SPACES UNLESS NOTED OTHERWISE.
7. AT THE COMPLETION OF DAILY WORK, THIS CONTRACTOR MUST REMOVE ALL RUBBISH OR WASTE MATERIAL BELONGING TO THIS CONTRACTOR FROM THE PROPERTY. KEEP THE JOB SITE FREE FROM ACCUMULATION OF WASTE MATERIALS AND RUBBISH.
8. SAFETY REGULATIONS ESTABLISHED BY OSHA SHALL BE MAINTAINED THROUGHOUT THE ENTIRE CONSTRUCTION PERIOD OF THE PROJECT.
9. IT IS THE INTENT OF THE ELECTRICAL SECTION OF THE SPECIFICATIONS AND THE ELECTRICAL DRAWINGS TO CALL FOR FINISHED WORK, TESTED AND READY FOR OPERATION. ANY APPARATUS, APPLIANCE, MATERIAL OR WORK NOT SHOWN ON DRAWINGS BUT MENTIONED IN THE SPECIFICATION, OR VICE VERSA, OR ANY INCIDENTAL ACCESSORIES NECESSARY TO MAKE THE ELECTRICAL INSTALLATION COMPLETE AND READY FOR OPERATION, EVEN IF NOT PARTICULARLY SPECIFIED, MUST BE FURNISHED, DELIVERED AND INSTALLED UNDER THIS SECTION WITHOUT ADDITIONAL EXPENSE TO THE OWNER. DISCREPANCIES OR A QUESTION OF INTENT, MUST BE REFERRED TO THE ENGINEER FOR DECISION BEFORE ORDERING ANY MATERIALS OR EQUIPMENT, OR BEFORE THE START OF ANY RELATED WORK, AND THE INTERPRETATIONS OF THE ENGINEER IS FINAL, CONCLUSIVE AND BINDING
10. ELECTRICAL INSPECTIONS: OBTAIN AN ELECTRICAL INSPECTION PREFORMED BY AN INSPECTOR THAT IS A MEMBER OF THE INTERNATIONAL ASSOCIATIONS OF ELECTRICAL INSPECTORS.
1. B. MATERIALS
1. RACEWAYS/CONDUIT BODIES/FITTINGSA. ELECTRIC METALLIC TUBING MUST BE HOT DIPPED STEEL CONFORMING TO UL STANDARD NO. 797. TUBING SHALL BE AS MANUFACTURED BY REPUBLIC STEEL, ALLIED TUBE OR EQUAL. B. PVC CONDUIT SCHEDULE 40 FOR COMPLYING WITH NEMA TC2 AND UL651.C. FLEXIBLE METAL CONDUIT MUST BE SINGLE STRIP, CONTINUOUS, FLEXIBLE, INTERLOCKED DOUBLE WRAPPED STEEL, GALVANIZED INSIDE AND OUTSIDE, FORMING SMOOTH WIRING CHANNEL.
FLEXIBLE METAL CONDUIT SHALL BE AS MANUFACTURED BY PYLE-NATIONAL, AMERICAN FLEXIBLE CONDUIT OR EQUAL.D. LIQUID TIGHT FLEXIBLE METAL CONDUIT MUST BE SIMILAR TO FLEXIBLE METAL CONDUIT, BUT WITH EXTRUDED MOISTURE AND OIL PROOF OUTER JACKET OF POLYVINYL CHLORIDE PLASTIC
AND BE AS MANUFACTURED BY AMERICAN FLEXIBLE CONDUIT, INTERNATIONAL HOSE OR EQUAL.E. COUPLINGS AND CONNECTORS FOR ELECTRIC METALLIC TUBING SHALL BE GALVANIZED STEEL SET SCREW TYPE AND SHALL BE MANUFACTURED BY O-Z/GEDNEY, THOMAS & BETTS OR EQUAL.
NO DIE-CAST FITTINGS.F. FITTINGS FOR PVC CONDUIT PER MANUFACTURERS RECOMMENDATIONS COMPLYING WITH NEMA TC3.G. FITTINGS FOR FLEXIBLE METALLIC CONDUIT MUST BE STEEL OR MALLEABLE IRON PLATED WITH CENTER STOP AND INSULATED THROAT AS MANUFACTURED BY O-Z/GEDNEY, THOMAS & BETTS
OR EQUAL. H. FITTINGS FOR LIQUID TIGHT FLEXIBLE METAL CONDUIT MUST BE MALLEABLE IRON ZINC PLATED SUITABLE FOR GROUNDING AND BE AS MANUFACTURED BY O-Z/GEDNEY, THOMAS & BETTS OR
EQUAL. I. CONDUIT BODIES/FITTINGS: PROVIDE CONDUIT FITTINGS AND OUTLET BODIES CONSTRUCTED OF CAST TYPE MATERIALS SUITABLE FOR USE IN THE RACEWAY SYSTEM BEING PROVIDED. USE
MATERIAL SIMILAR TO "FERALOY" AS MANUFACTURED BY CROUSE HINDS, OR MALLEABLE IRON AS MANUFACTURED BY APPLETON. J. OUTLET, SWITCH, AND JUNCTION BOXES, AND FITTINGS: PROVIDE SUCH PRODUCTS MEETING REQUIREMENTS OF NEC ARTICLE 370 FOR MATERIALS AND USES IN CONDUIT SYSTEMS, AND FED.
SPEC. W-J-800F. BOXES SHALL BE GALVANIZED STAMPED STEEL MANUFACTURED BY O.Z. GENDEY, CROUSE HINDS, THOMAS&BETTS, STEEL CITY OR RACO.
2. SUPPORTS, ANCHORS, FASTENERS AND SEALSA. FURNISH AND INSTALL ALL SUPPLEMENTARY STEEL, CHANNELS AND SUPPORT REQUIRED FOR THE PROPER INSTALLATION, MOUNTING AND SUPPORT OF ALL LIGHTING FIXTURES, AND
ELECTRICAL EQUIPMENT TO BE INSTALLED UNDER THIS CONTRACT. SUPPLEMENTARY STEEL, CHANNELS AND SUPPORTS ARE TO BE FURNISHED, INSTALLED AND SECURED WITH ALL FITTINGS, SUPPORT RODS AND APPURTENANCES REQUIRED FOR COMPLETE SUPPORT OR MOUNTING SYSTEM AND MUST BE UL LISTED, GALVANIZED STEEL, AND MANUFACTURED BY MIDLAND-ROSS, UNISTRUT, POWER-STRUT, T.J. COPE, CHALFANT OR EQUAL
3. CONDUCTORSA. ALL CONDUCTORS RATED FOR 600 VOLT FOR THE WIRING OF FEEDERS, BRANCH CIRCUITS, AUXILIARY SYSTEM WIRING AND CONTROL WIRING SHALL BE SOFT DRAWN COPPER AND MUST
HAVE A CONDUCTIVITY OF NOT LESS THAN 98 PERCENT OF THE ANSI STANDARD ANNEALED COPPER. CONDUCTORS MUST BEAR THE MARKINGS OF THE UNDERWRITERS' LABORATORIES, THE AWG SIZE, TYPE INSULATION, MAXIMUM PERMISSIBLE VOLTAGE, THE MANUFACTURER'S NAME AND TRADE MARK. WIRING SHALL BE A MINIMUM OF #12 AWG SOLID. WIRE AND CABLE MUST BE TYPE THHN/THWN INSULATION, 600V, RATED FOR 75 DEGREES C IN WET LOCATIONS AND 90 DEGREES C IN DRY LOCATIONS. WIRE AND CABLES SHALL BE UL LISTED, BEAR THE UL LABEL AND BE MANUFACTURED BY ROME CABLE CORPORATION, GENERAL CABLE CORPORATION, TRIANGLE/PWC OR APPROVED EQUAL.
B. MC CABLE: FLEXIBLE METAL CLAD CABLE WITH ALUMINUM INTERLOCKING ARMOR, GALVANIZED STEEL FITTINGS, THHN/THWN INSULATED #12 AWG CONDUCTORS WITH FULL SIZE INSULATED GREEN EQUIPMENT GROUND CONDUCTOR. MANUFACTURED BY AFC CABLE SYSTEMS OR EQUAL.
C. ANY CABLES/CONDUCTORS NOT INSTALLED IN RACEWAY SHALL BE PLENUM RATED.D. COMMUNICATION CABLING
a. CABLE: PROVIDE CATEGORY 6, 100 OHM, 23 AWG, FOUR PAIR TWISTED SHIELDED CABLE, PLENUM RATED, BLUE JACKET GENERAL CABLE, MOHAWK CABLE OR COMSCORE.b. JACKS: CATEGORY 6 TYPE, COMPLY WITH TIA-568-C.2, IDC TYPE WITH MODULES DESIGNED FOR PUNCH DOWN. PROVIDE SINGLE, HIGH IMPACT PLASTIC FACEPLATE. PANDUIT OR
ACCEPTABLE EQUAL. c. PATCH PANEL: CATEGORY 6 TYPE WITH IDC CONNECTIONS BUILT-IN, UNIVERSAL T568A OR T568B WIRING, PROVIDE LABELS FOR EACH PORT. PANDUIT OR ACCEPTABLE EQUAL.d. PATCH CORDS: PROVIDE (2) PATCH CORDS WITH INTEGRAL PLUGS ON EACH END. (1) SHALL BE 3 FT AND (1) SHALL BE 5 FT.
4. WIRING DEVICESA. TOGGLE SWITCHES MUST BE OF THE TOTALLY ENCLOSED, FLUSH TUMBLER TYPE AND MUST BE SPECIFICATION GRADE. TOGGLE SWITCHES SHALL BE GRAY COLOR AS MANUFACTURED BY
ARROW-HART, BRYANT, HUBBELL OR PASS & SEYMOUR.B. RECEPTACLES MUST BE SPECIFICATION GRADE AND BE SUPPORTED BY MOUNTING YOKE HAVING PLASTER EARS. RECEPTACLES MUST BE SIDE OR BACK WIRED WITH SCREW TERMINALS. ALL
RECEPTACLES MUST BE OF THE GROUNDING TYPE AND BE CONNECTED TO THE METAL MOUNTING YOKE. A TERMINAL MUST BE PROVIDED FOR GROUND WIRE ON ALL RECEPTACLES. RECEPTACLES FINISH MUST BE GRAY COLOR. RECEPTACLES SHALL BE MANUFACTURED BY ARROW-HART, BRYANT, HUBBELL OR PASS & SEYMOURa. WHERE CALLED FOR, PROVIDE GROUND FAULT CIRCUIT INTERRUPTER (GFCI), NEMA 5-20R, GRAY COLOR, COMPLYING WITH UL 498, UL943, AND FS W-596.
C. PROVIDE SPECIFICATION GRADE DEVICE PLATES. SELF-EXTINGUISHING THERMOPLASTIC NYLON "UNBREAKABLE" COVER PLATES, 0.070" THICK, GRAY COLOR. PLATES MUST BE OF APPROPRIATE TYPE AND SIZE FOR WIRING AND CONTROL DEVICES, SIGNAL AND TELEPHONE OUTLETS. DEVICE PLATES MUST BE BY THE SAME MANUFACTURE AS THE DEVICE.
D. WIRE AND CABLE CONNECTORS FOR #8 AWG AND SMALLER MUST BE OF THE PRESSURE INDENT TYPE WITH AN INSULATING COVER EQUAL TO BUCHANAN ELECTRIC PRODUCTS. CONNECTIONS TO MOTOR LEADS MUST BE MADE WITH SOLDERLESS LUGS SIMILAR TO BURNDY ENGINEERING COMPANY.
E. LIGHTING CONTROLa. CEILING MOUNT OCCUPANCY/VACANCY SENSOR SHALL BE DUAL TECHNOLOGY TYPE (PIR/ULTRASONIC) WITH 360 DEGREE VIEWING ANGLE OF 1500 SF COVERAGE, ADJUSTABLE OFF
DELAY, 30 SECONDS TO 30 MINUTES, ADJUSTABLE SENSITIVITY, WHITE FINISH WITH 24VDC LOW VOLTAGE OPERATION. PROVIDE WITH ASSOCIATED POWER PACK WATTSTOPPER DT-305 SENSOR AND #BZ SERIES POWER PACK OR ACCEPTED EQUAL.
b. WALLBOX STYLE OCCUPANCY/VACANCY SENSOR SHALL BE DUAL TECHNOLOGY TYPE WITH 180 DEGREE VIEWING ANGLE OF 900 SF COVERAGE, ADJUSTABLE OFF DELAY, 30 SECONDS TO 30 MINUTES, ADJUSTABLE SENSITIVITY, WALLSWITCH GRAY FINISH WITH 120/277 VOLT LINE VOLTAGE OPERATION AS REQUIRED. MANUAL 'ON'/AUTOMATIC 'OFF' WATTSTOPPER DSW-301, FOR DUAL CIRCUIT OPERATION DSW-301 OR ACCEPTED EQUAL.
1. FIRE SEALANTSA. FIRE STOP SEALANTS USED TO SEAL ALL OPENINGS AROUND ELECTRICAL RACEWAY SYSTEMS PASSING THROUGH FIRE RATED WALLS MUST BE OF THE FIRE RETARDANT SILICONE FOAM TYPE.
THE SEALANT MUST BE PLIABLE IN CHARACTER CAPABLE OF ADHERING ITSELF TO THE SURROUNDING SURFACES WITHIN THE VOID BEING FILLED. THE SEALANT MUST REMAIN IN THE PLIABLE STATE PERMITTING NORMAL BUILDING VIBRATION AND ALLOWING FOR MATERIAL EXPANSION AND CONTRACTION WITHOUT CRACKING OR CRUMBLING. FIRE STOP SEALANTS MUST BE FLAME SAFE AS MANUFACTURED BY THOMAS & BETTS OR APPROVED EQUAL.
2. IDENTIFICATIONA. NAMEPLATES MUST BE THREE-PLY BLACK BAKELITE WITH 1/4 INCH HIGH ENGRAVED WHITE LETTERS AND TWO (2) MOUNTING HOLES, NAMEPLATES MUST BE SECURELY ATTACHED TO
EQUIPMENT WITH STAINLESS STEEL SCREWS OR RIVETS. WORDING OF THE NAMEPLATES MUST BE IN CONFORMANCE WITH NOTES ON THE DRAWINGS. NAMEPLATES MUST BE PROVIDED ON THE FOLLOWING EQUIPMENT; MOTOR CONTROLS, REMOTE OPERATING STATION, SAFETY SWITCHES, PILOT LIGHTS AND CONTROL DEVICES IDENTIFYING THE UNITS CONTROLLED OR PROTECTED. NAMEPLATES MUST BE PROVIDED FOR ALL AUXILIARY SYSTEM EQUIPMENT AS INDICATED AND INCLUDED UNDER OTHER PARAGRAPHS OF THIS SECTION.
3. DISCONNECT SWITCHESA. PROVIDE DISCONNECT SWITCHES FUSED OR UNFUSED AS SHOWN ON DRAWINGS. SWITCHES MUST BE NEMA TYPE HD SAFETY SWITCHES FOR HEAVY DUTY WITH INTERLOCKING COVER, SIDE
OPERATED. SWITCH ENCLOSURE MUST BE NEMA 3R FOR EXTERIOR APPLICATIONS, UNLESS OTHERWISE NOTED SHALL BE NEMA 1 FOR INTERIOR APPLICATIONS. CURRENT CARRYING PARTS MUST BE SILVER PLATED. DISCONNECT SWITCHES SHALL BE AS MANUFACTURED BY ONE OF THE FOLLOWING; GENERAL ELECTRIC, CUTLER-HAMMER, SQUARE D OR SIEMENS.
4. PANELBOARDSA. PANELBOARDS SHALL HAVE COPPER BUS WITH BOLTED BREAKERS, FULLY RATED NEUTRAL BUS AND FULLY RATED INTERRUPTING CAPACITY; NO SERIES RATED SYSTEM PERMITTED. PROVIDE
WITH BLANK END WALLS (NO PRE-PUNCHED BOXES), DOOR-IN-DOOR HINGED TRIM, INTERRUPTING RATING AS CALLED FOR, NUMBER OF CIRCUITS AS INDICATED. SQUARE D NQOD SERIES (240VAC) OR ACCEPTED EQUAL. MOUNT TOP OF PANEL AT 72-INCHES ABOVE FINISHED FLOOR.
5. LIGHTING FIXTURESA. PROVIDE LIGHTING FIXTURES AS SPECIFIED ON LIGHTING FIXTURE SCHEDULE, COMPLETE WITH HOUSINGS, LIGHT EMITTING DIODE MODULES OR PANELS, REFLECTORS, DRIVERS AND WIRING.
SHIP FIXTURES FACTORY-ASSEMBLED WITH PARTS REQUIRED FOR A COMPLETE INSTALLATION. LIGHTING FIXTURES PROVIDED MUST CARRY THE UL LABEL. DESIGN FIXTURES WITH CONCEALED HINGES AND CATCHES, WITH METAL PARTS GROUNDED AS COMMON UNIT.
10. FIRE ALARM SYSTEMS:A. PROVIDE NEW DEVICES COMPATIBLE WITH EXISTING ADDRESSABLE FIRE ALARM SYSTEM AS INDICATED ON DRAWINGS. PROVIDE PRODUCTS OF TYPES, SIZES, AND CAPACITIES INDICATED,
WHICH COMPLY WITH MANUFACTURER'S STANDARD DESIGN, MATERIALS, COMPONENTS; CONSTRUCT IN ACCORDANCE WITH PUBLISHED PRODUCT INFORMATION, AND AS REQUIRED FOR COMPLETE INSTALLATION. PROVIDE DETECTION DEVICES, MANUAL STATIONS AND ALARM NOTIFICATION APPLIANCES AS SHOWN ON THE DRAWINGS AND AS SPECIFIED HEREIN.
B. SYSTEM WIRING AND SUPERVISION:a. PROVIDE CLASS 1 INITIATING AND ALARM CIRCUITS WITH ELECTRICAL SUPERVISION FOR SHORTS AND OPEN CONDITIONS.b. POWER SUPPLIES: PROVIDE SYSTEM FOR OPERATION ON 120 VAC POWER SUPPLY. c. PROVIDE BATTERY BACK-UP AS SECONDARY POWER SUPPLY. DESIGN BATTERY BACK-UP TO TAKE OVER SUPPLY TO SYSTEM WITHIN 30 SECONDS OF LOSS OF PRIMARY SYSTEM TO 85%
VOLTAGE. PROVIDE BATTERY SYSTEM CAPABLE OF OPERATION OF SYSTEM FOR 24-HOURS UNDER NORMAL CONDITIONS AND THEN FOR NINTY MINUTES UNDER ALARM CONDITIONS.C. SYSTEM FEATURES: EQUIP AND WIRE SYSTEM SO THAT BY ENERGIZING FIRE ALARM AUDIBLE SIGNALING DEVICES WILL ALSO ACTIVATE THE FOLLOWING:
a. REMOTE STATION SYSTEMS, INCLUDING REMOTE SIGNAL TO CENTRAL SECURITY STATION. b. FAN SHUT DOWN RELAYS. c. INTERIOR FLASHING STROBE LIGHTS, AND HORNS.
D. WIRING SYSTEM MATERIALS: a. PROVIDE WIRE AND CABLE IN ACCORDANCE WITH REQUIREMENTS OF MANUFACTURER.b. PROVIDE CONDUCTOR SIZES AWG #14, OR LARGER, WITH MAXIMUM 19 STRANDS COPPER CONDUCTOR, 7 STRANDS FOR SIZES AWG #16 AND #18.
PROVIDE MULTICONDUCTOR CABLES FOR WIRE SIZES SMALLER THAN AWG #16.c. PROVIDE CONDUCTORS WHICH ARE LISTED AND APPROVED FOR FIRE ALARM USAGE.d. ALL CABLE SHALL BE PLENUM RATED.
E. CONTROL PANELS: PROVIDE FIRE ALARM CONTROL PANEL ENCLOSURES FOR HOUSING DEVICES AND CIRCUITS NECESSARY TO PERFORM REQUIRED FUNCTIONS, AND TO SERVICE AS TEST POINTS, AND TROUBLE-SIGNAL POINTS.a. DESIGN DEVICES TO BE MODULAR, PLUG-IN.b. PROVIDE CONTROL PANEL FOR OPERATION ON 120-VOLTS AC SUPPLY AND FOR 24-VOLTS DC SYSTEM OPERATION WITH BATTERY STAND-BY POWER SOURCE.c. CLASS B, SIGNAL LINE AND NOTIFICATION APPLIANCE CIRCUITS, MINIMUM 100 ADDRESSABLE POINT CONTROL PANEL. MINIMUM (2) NOTIFICATION APPLIANCE CIRCUITS.d. DIGITAL COMMUNICATOR: THE COMMUNICATOR MUST BE APPROVED TO COMPLY WITH APPLICABLE FCC CODES. UNIT MUST FEATURE EITHER PULSE OR TOUCH TONE DIALING. "CALL
WAITING" TONES SHALL NOT PREVENT PROPER OPERATION.F. MANUAL FIRE ALARM STATIONS: PROVIDE MANUFACTURER'S STANDARD CONSTRUCTION, RED ENCLOSURE, MANUAL FIRE ALARM STATIONS, SEMI-FLUSH MOUNT, DOUBLE ACTION,
ADDRESSABLE.G. AUTOMATIC FIRE DETECTORS: PROVIDE MANUFACTURER'S STANDARD CONSTRUCTION AUTOMATIC FIRE DETECTORS, OF THE FOLLOWING TYPES AND TEMPERATURE CHARACTERISTICS:
a. ADDRESSABLE AUTOMATIC HEAT DETECTORS: RATE OF TEMPERATURE RISE 15 DEG F (8 DEG C) PER MINUTE, SPOT TYPE, RESTORABLE, INTERCHANGEABLE ADDRESSABLE BASE. b. ADDRESSABLE AUTOMATIC SMOKE DETECTORS: PHOTOELECTRIC, SPOT TYPES, RESTORABLE, WITH PULSED INFRARED LED LIGHT SOURCE FOR OPERATION ON VOLTAGE INDICATED.
DESIGN DETECTOR FOR MOUNTING ON INTERCHANGEABLE TYPE ADDRESSABLE BASE. FLASHING LED INDICATOR FOR NORMAL OPERATION WHICH CHANGES TO STEADY ON ALARM CONDITION.
c. DUCT MOUNT SMOKE DETECTOR: ADDRESSABLE SMOKE DETECTOR AS DESCRIBED IN 17.2, DETECTOR TO BE ENCLOSED IN DUCT MOUNTED HOUSING, SAMPLING TUBE OF SUFFICIENT LENGTH AS DETERMINED IN FIELD, REMOTE TEST STATION WITH KEY LOCK.
H. NOTIFICATION APPLIANCES: PROVIDE MANUFACTURER'S STANDARD CONSTRUCTION ALARM LIGHTS WITH THE FOLLOWING FEATURES:a. COMBINATION HORN/STROBE: WALL (OR CEILING) MOUNT, RED COLOR, WHITE LETTERS "FIRE" MULTI-OUTPUT FIELD SELECTABLE CANDELA RATING 15, 30, 75, 110. THREE (3) HORN
SETTINGS WITH TEMPORAL, NON-TEMPORAL AND CODED SOUND PATTERNS, 12/24 VOLTS DC. STROBES SHALL BE SYNCHRONIZED. b. STROBE: SAME AS ABOVE EXCEPT STROBE ONLY, WALL MOUNT OR CEILING MOUNT, STROBES SHALL BE SYNCHRONIZED.
I. JUNCTION BOXES: PROVIDE FIRE ALARM JUNCTION BOXES PAINTED RED ENAMEL. J. FAN SHUTDOWN RELAY: PROVIDE MANUFACTURER'S STANDARD CONSTRUCTION FAN SHUTDOWN RELAY OF THE FOLLOWING TYPES:
a. COMPATIBLE WITH FIRE ALARM SYSTEM.b. 24VDC COIL. c. 4PDT, 20 AMP CONTACTS.
K. ADDRESSABLE MODULES: MONITOR MODULE OR CONTROL MODULE WITH ADDRESS SETTING, MONITOR OF DRY CONTACTS OR INTEGRAL RELAY TO CONTROL EXTERNAL SYSTEM DEVICES
1. EXECUTION
1. INSTALLATION OF CONDUITS AND WIRINGA. GENERAL: INSTALL CONCEALED CONDUITS, EITHER IN WALLS, SLABS, OR ABOVE HUNG CEILINGS. WHERE CONDUITS CANNOT BE CONCEALED IN FINISHED AREAS USE SURFACE RACEWAYS.
a. MECHANICALLY FASTEN TOGETHER METAL CONDUITS, ENCLOSURES, AND RACEWAYS FOR CONDUCTORS TO FORM CONTINUOUS ELECTRICAL CONDUCTOR. CONNECT TO ELECTRICAL BOXES, FITTINGS AND CABINETS TO PROVIDE ELECTRICAL CONTINUITY AND FIRM MECHANICAL ASSEMBLY.
B. CONDUIT INSTALLATION: PROVIDE CONDUIT WITH MINIMUM REQUIREMENTS AS FOLLOWS:a. USE STEEL ZINC-COATED EMT FOR FEEDER AND BRANCH CIRCUIT WIRING EXPOSED OR CONCEALED ABOVE CEILINGS OR IN FLOOR SLAB.b. USE FLEXIBLE CONDUIT FROM OUTLET BOXES TO RECESSED LIGHTING FIXTURES, AND FINAL 24" OF CONNECTION TO MOTORS, OR OTHER ITEMS SUBJECT TO MOVEMENT OF VIBRATION.
USE FLEXIBLE METAL CONDUIT OR MC CABLE FOR BRANCH CIRCUIT WIRING INSTALLED HORIZONTALLY IN WALLS AND PARTITIONS BETWEEN OUTLET BOXES.C. CONDUIT SHALL BE SECURELY SUPPORTED FROM BUILDING CONSTRUCTION SEPARATELY FROM OUTLETS AND BOXES. CONDUIT SHALL NOT BE SUPPORTED BY THE CEILING SUPPORT SYSTEM.
MINIMUM SIZE SHALL BE 1/2".
2. USE LIQUID-TIGHT FLEXIBLE CONDUIT WHERE SUBJECTED TO ONE OR MORE OF THE FOLLOWING CONDITIONS:A. EXTERIOR LOCATIONB. MOIST OR HUMID ATMOSPHERE WHERE CONDENSATE CAN BE EXPECTED TO ACCUMULATEC. CORROSIVE ATMOSPHERED. SUBJECTED TO WATER SPRAY OR DRIPPING OIL, WATER OR GREASE
3. USE EMT FOR FEEDERS AND BRANCH CIRCUIT WIRING IN MECHANICAL SPACES.
4. USE SURFACE MOUNTED METALLIC RACEWAY SYSTEM, WIREMOLD, OR APPROVED EQUAL. IN ALL FINISHED ROOMS, CORRIDORS, VESTIBULES.
5. MC CABLE SHALL BE INSTALLED CONCEALED IN METAL STUD DRYWALL CONSTRUCTION AND CONCEALED NEATLY ABOVE CEILINGS SUPPORT BY BUILDING STRUCTURE.
6. ALL GROUNDING SHALL MEET OR EXCEED THE REQUIREMENTS OF NEC ARTICLE 250. RACEWAY SYSTEMS WHICH INCLUDES ALL METAL CONDUIT, PULLBOXES, JUNCTION BOXES, ENCLOSURES, MOTOR FRAMES, ETC. SHALL BE MADE TO FORM A CONTINUOUS CONDUCTING, PERMANENT GROUND CIRCUIT OF THE LOWEST PRACTICAL IMPEDANCE TO ENHANCE THE SAFE CONDUCTION OF GROUND FAULT CURRENTS AND TO PREVENT OBJECTIONABLE DIFFERENCES IN VOLTAGE BETWEEN METAL CURRENT CARRYING PARTS OF THE ELECTRICAL SYSTEM. PROVIDE A INSULATED EQUIPMENT GROUNDING CONDUCTOR IN ALL CIRCUITS, CONDUIT SYSTEM SHALL NOT BE USED AS THE EQUIPMENT GROUNDING CONDUCTOR. CONDUCTOR SIZE SHALL BE AS REQUIRED BY NEC, ARTICLE 250. ALL EQUIPMENT GROUND BUS, GROUND PADS, FRAMES, ENCLOSURES, ETC. SHALL HAVE SURFACES AT THE POINT OF CONNECTION THOROUGHLY CLEANED AND BRIGHTENED JUST PRIOR TO ACTUALLY MAKING THE CONNECTION. TOUCH-UP DAMAGED PAINTED SURFACES. SPLICES IN WIRE OR CABLE GROUNDING CONDUCTORS ARE PROHIBITED. SOLDER PROHIBITED FOR CONNECTIONS.
7. COLOR CODING SHALL BE MAINTAINED FOR ALL BRANCH CIRCUIT WIRING THROUGHOUT THE PROJECT. COLOR IMPREGNATE INSULATION SHALL BE USED FOR ALL CONDUCTORS UP TO AND INCLUDING NO. 6 AWG.A. PHASES NEUTRAL AND GROUND CONDUCTORS FOR THE 120/208/240V SYSTEM MUST BE COLOR CODED AS FOLLOWS:
a. PHASE A - BLACKb. PHASE B - REDc. PHASE C - BLUEd. NEUTRAL - WHITEe. EQUIPMENT GROUND CONDUCTORS - GREEN
B. ALL WIRE AND CABLE SHALL BE INSTALLED IN AN APPROVED RACEWAY. SPLICES AND CONNECTIONS SHALL BE MADE IN ACCESSIBLE OUTLETS, PULLBOXES OR JUNCTION BOXES USING MECHANICAL CONNECTOR SIMILAR TO BUCHANAN SPLICE CAPS, IDEAL WIRE NUTS OR T&B STAKON JOINTS, FOR WIRE SIZES #10 AND SMALLER. INSULATE ALL SPLICES, TAPS AND CONNECTIONS WITH A UL LABELED PLASTIC TAPE OR MOLDED COMPOSITION CAP. USE UL APPROVED LUBRICANTS FOR WIRE PULLING. OIL OR GREASE BASE LUBRICANTS WILL NOT BE APPROVED.
C. MAKE ALL CONNECTIONS TO DISCONNECT SWITCHES, MOTOR CONTROLLERS, MOTORS AND OTHER EQUIPMENT SHOWN ON THE PLANS. EXIT LIGHTS, FIRE ALARM AND EMERGENCY CIRCUITS SHALL BE INSTALLED IN SEPARATE CONDUIT SYSTEMS. INSTALL A MAXIMUM OF 3 SINGLE PHASE CIRCUITS IN A SINGLE RACEWAY, UNLESS OTHERWISE SPECIFICALLY CALLED FOR (SIX (6) CURRENT CARRYING CONDUCTORS MAXIMUM PLUS GROUND). PROVIDE DEDICATED NEUTRAL FOR EACH HOT LET, (NO SHARED NEUTRALS PERMITTED).
8. INSTALLATION OF FIRE ALARM SYSTEMA. INSTALL WIRING OF POWER-LIMITED CIRCUITS EXPOSED PLENUM RATED CABLE..B. INSTALL WIRES AND CABLES WITHOUT SPLICES. MAKE CONNECTIONS AT TERMINAL STRIPS IN CABINETS OR AT EQUIPMENT TERMINALS. MAKE SOLDERED SPLICES IN ELECTRONIC CIRCUITS
IN CONTROL CABINETS.C. WIRING: WIRING OF FIRE ALARM SYSTEM IS WORK OF THIS SECTION, BUT IS NOT SPECIFICALLY DETAILED ON DRAWINGS.
a. COMPLETE WIRING IN ACCORDANCE WITH MANUFACTURER'S REQUIREMENTS. COLOR CODE WIRING AND INSTALL PER MANUFACTURER'S POINT-TO-POINT WIRING DIAGRAM. DETERMINE EXACT NUMBER OF WIRES FOR EACH FIRE AREA ZONE FROM NUMBER AND TYPES OF DEVICES INSTALLED.
b. WHERE THERE ARE A NUMBER OF POWER REQUIRING DEVICES SUCH AS SMOKE DETECTORS, FAN RELAYS, DOOR HOLDERS AND SMOKE DAMPER OPERATORS INSTALLED IN A CIRCUIT, GROUP IN NUMBERS SO POWER REQUIRED DOES NOT EXCEED 80% OF MANUFACTURER'S POWER SUPPLY RATING. PROVIDE EXTRA WIRING, OR EXTRA POWER SUPPLIES REQUIRED TO FULFILL THAT REQUIREMENT. IN ADDITION, PROVIDE EXTRA OR LARGER SIZE WIRING TO ALLEVIATE VOLTAGE DROPS WHICH MAKES DEVICE OPERATE BEYOND VOLTAGE LIMITS FOR WHICH IT WAS DESIGNED. DETERMINE ABOVE WITH MANUFACTURER'S REPRESENTATIVE WHILE EQUIPMENT IS BEING INSTALLED.
D. CONNECTION AND SUPERVISION: MAKE CONNECTIONS TO PANEL UNDER MANUFACTURER'S SUPERVISION. COMPLETE CONNECTIONS TO PANEL UTILIZING MANUFACTURER'S TECHNICIANS.E. SYSTEM TEST AND APPROVAL:
a. PRIOR TO FINAL ACCEPTANCE OF SYSTEM, MANUFACTURER OF SYSTEM SHALL, IN PRESENCE OF CONTRACTOR AND OWNER'S REPRESENTATIVE, TEST EACH SENSING OR DETECTION AND ALARM DEVICE.
b. SUBMIT COPY OF TEST RESULTS IN DUPLICATE AFTER SIGNED BY OWNER'S REPRESENTATIVE TO OWNER, OWNER'S INSURANCE COMPANY AND LOCAL FIRE PROTECTION AUTHORITY.
500 East Sixth StreetJamestown, NY 14701716-483-3153
labellapc.com
DRAWING NAME:
It is a violation of New York Education Law Article 145 Sec.7209, for any person, unless
acting under the direction of a licensed architect, professional engineer, or land
surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or
land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the
item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the
1. EXTEND BRANCH CIRCUITS IN THIS AREA TO THE FOLLOWING BRANCH PANELBOARDS, UNLESS OTHERWISE NOTED:
• 120 / 208V PANELBOARDS• PANEL "D" - NORMAL POWER
BRANCH CIRCUIT NOTES :
1. LL1 FIXTURE THIS LOCATION, TO BE INSTALLED VERTICAL FOR SIGN ILLUMINATION. (4) FIXTURES TOTAL, STARTING AT 9'-0"AFG.
2. LL1 FIXTURE INSTALLED AT 14'-11" AFG FOR SIGN ILLUMINATION.
3. AUTO DOOR - FURNISH AND INSTALL ALL CONDUITS, WIRING, OUTLET OR JUNCTION BOXES, AND ANY OTHER AUXILIARY ELECTRICAL COMPONENTS NECESSARY FOR PROPER DOOR OPERATION.
4. FEED POWER FROM WITHIN INTERIOR, NOT SURFACE MOUNTED CONDUIT ON EXTERIOR.
KEYED NOTES :
1/8" = 1'-0"E101
1 1ST FLOOR LIGHTING PLAN1/8" = 1'-0"E101
2 1ST FLOOR POWER & SYSTEMS PLAN
1/8" = 1'-0"E101
3 1ST FLOOR DEMOLITION PLAN
1/8" = 1'-0"E101
4 EXTERIOR BUILDING LIGHTING ELEVATION
A. EXISTING FIRE ALARM SYSTEM IS HONEYWELL FARENHYT SERIES MODEL IFP-300. VENDOR IS FSC SYSTEMS, LLC 716-664-5336.
B. EXISTING ACCESS CONTROL AND SECURITY ALARM SYSTEM IS HONEYWELL NETAXS SERIES. VENDOR IS FSC SYSTEMS, LLC 716-664-5336.
GENERAL NOTES:
NOT TO SCALEE101
5 POWER DISTRIBUTION ONE-LINE DIAGRAM
1/8" = 1'-0"E101
6 EXTERIOR BUILDING LIGHTING SECTION
1 1
Revisions
NO: DATE: DESCRIPTION:
06/28/2021
REFERENCED PRODUCTS LISTED OF MANUFACTURER'S SERIES &/OR MODEL NUMBERS ARE LISTED TO GIVE A REPRESENTATION OF ACCEPTABLE BUILD QUALITY AND GENERALLY CONFORM TO THE LUMINAIRE DESIGN INTENT - LISTED MANUFACTURER'S STANDARD PRODUCTS MAY REQUIRE CUSTOM MODIFICATIONS TO MEET THE REQUIREMENTS SPECIFIED IN THE LUMINAIRE SCHEDULE & IN THE SPECIFICATIONS. LISTED SIZES, LAMPING, LUMEN OUTPUT, EFFICACY, INPUT POWER, OPTIONS, & TYPES OF LUMINAIRES MAY NOT BE AVAILABLE FROM ANY GIVEN MANUFACTURER OR SERIES LISTED. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE PRODUCTS THAT MEET ALL LISTED REQUIREMENTS IN THE LUMINAIRE SCHEDULE AND SPECIFICATIONS. EQUIVALENT PRODUCTS BY OTHER MANUFACTURERS MAY BE CONSIDERED, PRIOR TO BID, AND APPROVED AT THE DISCRETION OF THE DESIGN ENGINEER.
DETERMINE SPECIFIC LUMINAIRE PART NUMBERS BASED ON THE REFERENCED PRODUCT SERIES, WRITTEN DESCRIPTIONS, & SPECIFICATIONS.
ALERT ARCHITECT/ENGINEER TO DISCREPANCIES PRIOR TO BID.
UNLESS NOTED OTHERWISE, LED DRIVERS SHALL HAVE A POWER FACTOR OF MORE THAN 0.9 AND A TOTAL HARMONIC DISTORTION OF LESS THAN 20%.
UNLESS NOTED OTHERWISE, LED LUMINAIRES SHALL HAVE 3-STEP MACADAM ELLIPSE/STANDARD DEVIATION COLOR MATCHING (SDCM) OR LESS.
LUMINAIRE SHALL HAVE A WARRANTY OF NOT LESS THAN 5 YEARS.
WHERE A LUMINAIRE IS CALLED OUT TO BE 'DLC QUALIFIED' OR 'DLC PREMIUM QUALIFIED', PROVIDE DOCUMENTATION OF SPECIFIC MODEL NUMBER FOR DLC LISTING IN PRODUCT DATA SUBMITTAL. CONTRACTOR SHALL BEAR FINANCIAL RESPONSIBILITY OF REJECTED UTILITY REBATES DUE TO INSTALLING LUMINAIRES THAT ARE NOT DLC QUALIFIED AS CALLED OUT IN THIS SCHEDULE.
BFCCTDLCD/ILGNTPAFPPCPRISM
BALLAST FACTORCORRELATED COLOR TEMPERATUREDESIGN LIGHTS CONSORTIUMDIRECT / INDIRECTLAY-IN GRIDNARROW TEE GRIDPAINT AFTER FABRICATIONPOLYESTER POWDER COATPRISMATIC
ABBREVIATIONS:
QTYREFNSSTBSUNIVHR
QUANTITYREFERENCESTAINLESS STEELTO BE SELECTED BY ARCHUNIVERSAL 120-277VACHOUR
LUMINAIRE SCHEDULE
1. N/A
A.
B.
C.
D.
E.
F.
G.
TYPE DESCRIPTIONINSTALLATION
METHOD
MAX DEPTH SHIELDING / OPTICS FEATURES / OPTIONS REFERENCED PRODUCTS NOTES
LAMP/LIGHT SOURCE BALLAST/DRIVER
SPEC REFN QTY SPEC REFN VOLT
MAXINPUT WATTS
NOTES:
GENERAL NOTES:
LP1 DIRECT/INDIRECT PENDANT HUNG 1x4 LED LUMINAIRE
AIRCRAFT CABLE
SUSPENDED
- UNIV 11 W/ft
CORELITE - JAYLUM SERIESPEERLESS - BRUNO SERIESLEDALITE - SYNC SERIES
3" 0-10V LED DIMMING DRIVER(10-100% LIGHT OUTPUT RANGE)
LED 3500K
≥ 90 CRIMIN 1250 lm/ft≥ 115 lm/W
L70 ≥ 50K HR
NOMINAL RECTLINEAR SHAPE; 9"W X 48"L X 3"HDIE-FORMED 20 GAUGE CRS STEEL BODY HOUSINGCAST ALUMINUM ROUNDED ENDCAPSCUSTOM COLOR PPC FINISH, TBDDLC LISTED
FROSTED WHITE ACRYLIC LENS, NOM 4" WIDEUPLIGHT: MIN 20% / MAX 30%DNLIGHT: MIN 70% / MAX 80%TOP DUSTCOVER
-
LD1 6" ROUND OPEN LEDDOWNLIGHT
RECESSED - UNIV 15 LIGHTOLIER - CALCULITE C* SERIESGOTHAM - EVO SERIESPORTFOLIO - LD*B SERIESCREE - ESSENTIA SERIES
10" LED DRIVER UL DAMP LOCATIONSHEET METAL FRAME IN HOUSINGDLC LISTED
REMOTE PHOSPHOR OR LENSED(NO PIXILATION)WIDE BEAMLOW IRIDESCENTSEMI-SPECULARSELF FLANGING TRIM
-LED3500K CCT≥ 80 CRI
MIN 1000 lm≥ 70 lm/W
L70 ≥ 50K HR
LB1 BOLLARD STYLELUMINAIRE
BOLLARD,3'-0" HEIGHT
- UNIV 15 SELUXLUMINAIRE:IBL-3-4QS-30-BK-UNV-PC
- ELECTRONIC LEDDRIVER
POWDER COATED BLACK CASTALUMINUM HOUSING WITH INTEGRAL PHOTOCELL
FROSTEDPOLYCARBONATE WITHTYPE V DISTRIBUTION
-LED3000°K
NOM 900 lm≥ 80 CRI
LL1 EXTERIORWALL WASH FACADE LINEAR LEDLUMINAIRE
SURFACEPER
ELEVATION
- UNIV 5 W/LF LUMENPULSE - LUMENFACADE-LOGHSERIESPHILIPS - eW GRAZE POWERCORESERIESCOOPER - IO LINE 2.0 SERIES
3" LED3000K CCT≥ 78 CRI
MIN 200 lm/ft.≥ 40 lm/W
L70 ≥ 50K HR
EXTRUDED ALUMINUM HOUSINGNOMINALLY 24"L X 5"W X 2"HUL WET LOCATION/IP66CUSTOM COLOR FINISH, TBDADJUSTIBLE WALL MOUNTING BRACKET
ASYMMETRIC WALLWASH OPTIC -LED DRIVER-25 DEGREES C
DESIGNATION LOCATION DESCRIPTION LOAD VOLTAGE PHASE POWER SOURCECIRCUITNUMBER
PROTECTIVEDEVICE
RATING (A)
NUMBEROF
POLES CONDUCTORS & CONDUITCONTROLLER
TYPECONTROLLER
SIZECONTROLLERACCESSORIES DISCONNECT NOTES
ACCU-1 ROOF AIR COOLED CONDENSING UNIT 25.9 MCA 208 V 1 PANEL "D" 4,6 40 2 (2)#10, (1)#10G IN 3/4"C INTEGRAL TO UNIT - - 60A-2P UNFUSED NEMA 3R -
ACCU-2 ROOF AIR COOLED CONDENSING UNIT 25.9 MCA 208 V 1 PANEL "D" 10,12 40 2 (2)#10, (1)#10G IN 3/4"C INTEGRAL TO UNIT - - 60A-2P UNFUSED NEMA 3R -
AHU-1 01 SHOP/DISPLAY, 02 ART CLASSROOM AIR HANDLING UNIT 8.7 MCA 120 V 1 PANEL "D" 8 20 1 (2)#12, (1)#12G IN 3/4"C INTEGRAL TO UNIT - - LOCKABLE TOGGLE SWITCH -
AHU-2 01 SHOP/DISPLAY, 02 ART CLASSROOM AIR HANDLING UNIT 8.7 MCA 120 V 1 PANEL "D" 14 20 1 (2)#12, (1)#12G IN 3/4"C INTEGRAL TO UNIT - - LOCKABLE TOGGLE SWITCH -
EF-1 03 TOILET EXHAUST FAN 1 18W 120 V 1 PANEL "D" 23 20 1 (2)#12, (1)#12G IN 3/4"C OCCUPANCY SENSOR - - INTREGAL TO UNIT CONNECT TO ROOM LIGHTING SENSOR
EF-2 01B STORAGE EXHAUST FAN 2 18W 120 V 1 PANEL "D" 23 20 1 (2)#12, (1)#12G IN 3/4"C VACANCY SENSOR - - INTREGAL TO UNIT CONNECT TO ROOM LIGHTING SENSOR
K-1 (KILN) 05 KILN KILN (PARAGON DRAGON 24) 20 KW 240 V 3 Template, 0 V/208 V, Three Phase, 3 Wires, Delta 1 80 3 (3)#4, (1)#8G IN 1" C TO XFMR, (3)#6, (1)#10G IN 3/4" C FROM XFMR TO EQPT INTEGRAL TO UNIT - - 60A-3P FUSED NEMA 1 WITH 60A FUSES PROVIDE (2) BOOST XFMRS HAMMOND Q002ESCF OR EQUAL, CONNECTED PER MANUFACTURERS INSTRUCTIONS
KH-1 (HOOD) 05 KILN KILN HOOD 1/15HP 120 V 1 PANEL "D" 3 20 1 (2)#12, (1)#12G IN 3/4"C INTEGRAL TO UNIT - - CORD & PLUG PROVIDE DUPLEX RECEPTACLE, COORDINATE EXACT LOCATION IN FIELD
OD-1 ART CLASSROOM 02 OVERHEAD DOOR 1 1/2 HP 120 V 1 PANEL "D" 17 20 1 (2)#12, (1)#12G IN 3/4"C FURNISHED WITH UNIT - - LOCKABLE MOTOR RATED TOGGLESWITCH
START/STOP PUSH BUTTON INCLUDED WITH OVERHEAD DOOR
OD-2 ART CLASSROOM 02 OVERHEAD DOOR 2 1/2 HP 120 V 1 PANEL "D" 19 20 1 (2)#12, (1)#12G IN 3/4"C FURNISHED WITH UNIT - - LOCKABLE MOTOR RATED TOGGLESWITCH
START/STOP PUSH BUTTON INCLUDED WITH OVERHEAD DOOR
ESTIMATED DEMAND - NC HEAT/COOL: 124 A
NON-COINCIDENT HEATING/COOLING: 0 A
ESTIMATED DEMAND CURRENT: 124 A
MOTOR LOAD 16110 VA 108.27% 17442 VA CONNECTED CURRENT: 121 A
RECEPTACLE 7820 VA 100.00% 7820 VA ESTIMATED DEMAND LOAD: 44788 VA
LIGHTING 1260 VA 100.00% 1260 VA CONNECTED LOAD: 43455 VA
TOTAL CONNECTED PHASE LOADS: 14602 VA 13603 VA 15250 VA
41 SPARE 20 A 1 0 0 42
39 SPARE 20 A 1 0 0 40
37 SPARE 20 A 1 0 0
3 30 A SPARE
38
35 SPARE 20 A 1 0 0 36
33 SPARE 20 A 1 0 02 30 A SPARE
34
31 POWER DOOR OPERATOR 20 A 1 1000 0 32
29 EXIT SIGNS 20 A 1 30 0 30
27 CONV REC - ROOF/JAN CLOSET 20 A 1 360 0
3 20 A SPARE
28
25 EXTERIOR LIGHTING 20 A 1 250 0 26
23 KILN/TOILET/JAN/ELEC LIGHTING 20 A 1 433.9 02 20 A SPARE
24
21 MAIN AREA LIGHTING 20 A 1 587.6 0 1 30 A SPARE 22
19 OVERHEAD DOOR 1 20 A 1 1800 0 1 20 A SPARE 20
17 OVERHEAD DOOR 1 20 A 1 1800 1000 1 20 A TOILET PUMP WC-1 18
15 GENERAL RECEPTS 20 A 1 900 1000 1 20 A SINK PUMP P-1 REC 16
13 GENERAL RECEPTS 20 A 1 1800 1044 1 20 A AHU-2 14
11 GENERAL RECEPTS 20 A 1 1260 2664.5 12
9 5408.3 2664.52 40 A ACCU-2
10
7 5408.3 1800 1 20 A AUH-1 8
5
KILN K-1 80 A 3
5408.3 2662.5 6
3 KILN HOOD 20 A 1 20 2662.52 40 A ACCU-1
4
1 KILN 20 A 1 1500 0 1 20 A SPARE 2
CKT CIRCUIT DESCRIPTION BKR POLES A B C POLES BKR CIRCUIT DESCRIPTION CKT
*** COORDINATE CIRCUIT BREAKER RATING WITH SPD MANUFACTURER
** REFER TO POWER DISTRIBUTION ONE-LINE DIAGRAM OR EQUIPMENT CONNECTION SCHEDULE(S) FOR TRIP RATING.
* PROVIDE GFCI TYPE BREAKER
PANELBOARD SCHEDULE NOTATION:
OPTIONS: ENCLOSURE TYPE: TYPE 1 MODIFICATIONS:
SERVICE ENTRANCE LABEL: NO MOUNTING: SURFACE MCB TRIP: 150 A
FED FROM: # OF WIRES: 4 BUS RATING: 150 A
# OF PHASES: 3 MAIN TYPE: MCB
LOCATION: ELEC. 01C DISTRIBUTION VOLTAGE: 208Y/120V FULLY RATED AIC: 22,000
DESIGNATION: PANEL "D"DESIGN BASE: SQUARE D NQ SERIES
PANEL "D"
FEEDER TAP
Revisions
NO: DATE: DESCRIPTION:
PANEL "D"
06/18/2021
BRANCH OFF TOP OF PIPE
PIPE TURNED UP
PIPE TURNED DOWN
BRANCH OFF BOTTOM OF PIPE
REDUCER
PIPE BREAK
BALL VALVE
DRAWING SYMBOLS
CHECK VALVE
BALANCE VALVE
EQUIPMENT TO BE REMOVED
KEY NOTE
SECTION CALLOUT
POINT OF CONNECTION
POINT OF DISCONNECTION
DEMOLITION KEY NOTE
DETAIL NUMBER
1
1
M-2
A
M-2
A
EXISTING PIPE, EQUIPMENT
NEW PIPE, EQUIPMENT
PIPE, EQUIPMENT
TO BE REMOVED
NOTE:NOT ALL SYMBOLS, ABBREVIATIONS ANDEQUIPMENT DESIGNATIONS MAY APPLY TO THISPARTICULAR PROJECT. ANY ADDITIONS OROMISSIONS FROM THIS LEGEND SHEET DOES NOTIMPLY INCLUSION AND/ OR EXCLUSIONS OF ANYPARTICULAR ITEM FROM THIS PROJECT.
SANITARY DRAIN
DOMESTIC HOT WATER SUPPLY
NG NATURAL GAS
SAN
DHW
VENT
DCW DOMESTIC COLD WATER
V
DOMESTIC HOT WATER RECIRCDHR
1. BUILDING CODE OF NEW YORK STATE2. MECHANICAL CODE OF NEW YORK STATE3. FIRE CODE OF NEW YORK STATE4. PLUMBING CODE OF NEW YORK STATE5. ENERGY CONSERVATION CONSTRUCTION CODE OF NEW
YORK STATE6. ACCESSIBLE AND USUABLE BUILDING AND FACILITIES-
CABO/ANSI A117.17. NATIONAL ELECTRIC CODE8. NFPA 13: STANDARD FOR THE INSTALLATION OF
SPRINKLER SYSTEMS
GENERAL NOTES
WASTEW
APPLICABLE CODES
ABBREVIATIONS
CO DCW DHR DHWDTW E FLA FT HD GPM HP HZ LAV MSB P PD PH RPM SAN SK TYP UG US V VTR W WC
CLEANOUT DOMESTIC COLD WATER DOMESTIC HOT RECIRCULATION DOMESTIC HOT WATER DOMESTIC TEMPERED WATEREXISTING FULL LOAD AMP HEAD IN FEET GALLONS PER MINUTE HORSEPOWER HERTZ LAVATORY MOP SERVICE BASIN PUMP PUMPED DISCHARGE PHASE REVOLUTIONS PER MINUTE SANITARY SINK TYPICAL UNDERGROUND UTILITY SINK VENT VENT THRU ROOF WASTE WATER CLOSET
SECTION 220517 - SLEEVES AND SLEEVE SEALS FOR PLUMBING PIPING1. SLEEVES
A. STEEL PIPE SLEEVES: ANTICORROSION COATED OR ZINC COATED, WITH PLAIN ENDS AND INTEGRAL WATERSTOP COLLAR.B. GALVANIZED-STEEL SHEET PIPE SLEEVES: ROUND TUBE CLOSED WITH WELDED LONGITUDINAL JOINT.
2. SILICONE SEALANTSA. SILICONE SEALANT: TYPE S, GRADE NS, CLASS 25, USE NT: SINGLE-COMPONENT, NONSAG, PLUS 25 PERCENT AND MINUS
25 PERCENT MOVEMENT CAPABILITY, NONTRAFFIC-USE, NEUTRAL-CURING SILICONE JOINT SEALANT.3. SLEEVE AND SLEEVE-SEAL SCHEDULE
A. INTERIOR PARTITIONS: PIPING SMALLER THAN NPS 6 : STEEL PIPE SLEEVES
SECTION 220523 - VALVES FOR PLUMBING PIPING1. DOMESTIC HOT- AND COLD-WATER BALL VALVES
A. BALL VALVES IN PIPE NPS 2-1/2 AND SMALLER:1. BRASS OR BRONZE BALL VALVES, TWO-PIECE WITH FULL PORT AND STAINLESS STEEL TRIM.
2. DOMESTIC HOT- AND COLD-WATER CHECK VALVESA. PIPE NPS 2 AND SMALLER:
1. BRONZE SWING CHECK VALVES, CLASS 150, BRONZE DISC WITH SOLDERED OR THREADED END CONNECTIONS.2. BRONZE SWING CHECK VALVES WITH PRESS-END CONNECTIONS.
B. PIPE NPS 2-1/2 AND LARGER:1. IRON SWING CHECK VALVES, CLASS 125, METAL SEATS WITH FLANGED END CONNECTIONS.
3. DOMESTIC COLD-WATER GATE VALVESA. PIPE NPS 2-1/2 AND LARGER: IRON GATE VALVES, NRS, CLASS 125 WITH FLANGED ENDS.
SECTION 220529 - HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT1. PERFORMANCE REQUIREMENTS
A. PROVIDE SUPPORTS AND ANCHORS FOR ALL EQUIPMENT INSTALLED UNDER THIS CONTRACT.B. PIPE HANGERS AND EQUIPMENT SUPPORTS DESIGNED BY CONTRACTOR.C. PROVIDE SUPPORT SPACING AS REQUIRED BY CODES.
2. COMPONENTSA. METAL PIPE HANGERS AND SUPPORTS: CARBON STEEL, STAINLESS STEEL AND COPPER.B. TRAPEZE PIPE HANGERS.C. METAL FRAMING SYSTEMS: MFMA MANUFACTURER.D. THERMAL HANGER-SHIELD INSERTS.E. PIPE STANDS.F. EQUIPMENT SUPPORTS.
SECTION 220553 - IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT1. EQUIPMENT LABELS: PLASTIC.2. WARNING SIGNS AND LABELS: 1/8 INCH THICK WITH ADHESIVE.3. PIPE LABELS: SELF-ADHESIVE.4. STENCILS: FIBERBOARD OR METAL.5. VALVE TAGS: 2” DIAMETERS STAINLESS STEEL, 0.025-INCH ALUMINUM, 0.032-INCH OR BRASS, 0.032-INCH MINIMUM
THICKNESS.A. TAG VALVES WITH NUMBER. PROVIDE TYPED LIST.
6. LABEL PIPES IN COMMON AREAS EVERY 25 FEET OF STRAIGHT RUN, WITHIN 2 FEET OF AN ELBOW AND ON EITHER SIDE OF WALLS.
A. SURFACE-BURNING CHARACTERISTICS: FLAME-SPREAD INDEX OF 25, AND SMOKE-DEVELOPED INDEX OF 50 FOR INSULATION INSTALLED INDOORS; ACCORDING TO ASTM E84.
2. PIPING INSULATION SCHEDULE, GENERALA. INSULATE DOMESTIC WATER PIPING TO WITH APPROPRIATE THICKNESS TO COMPLY WITH N.Y.S. ENERGY CONSERVATION
CONSTRUCTION CODE AND TO PREVENT CONDENSATION, ROOF DRAIN PIPING IN UNHEATED AREAS, AND AS DICTATED BY GOOD PRACTICE, AS FOLLOWS:
B. ITEMS NOT INSULATED: UNLESS OTHERWISE INDICATED, DO NOT INSTALL INSULATION ON THE FOLLOWING:1. DRAINAGE PIPING LOCATED IN CRAWL SPACES.2. BELOW-GRADE PIPING.3. CHROME-PLATED PIPES AND FITTINGS UNLESS THERE IS A POTENTIAL FOR PERSONNEL INJURY.
1. NPS 1 AND SMALLER: INSULATION SHALL BE THE FOLLOWING:a. MINERAL-FIBER, PREFORMED PIPE INSULATION, TYPE I: 1 INCH THICK.
2. NPS 1-1/4 AND LARGER: INSULATION SHALL BE THE FOLLOWING:a. MINERAL-FIBER, PREFORMED PIPE INSULATION, TYPE I: 1 INCH THICK.
B. DOMESTIC HOT AND RECIRCULATED HOT WATER: 1. NPS 1-1/4 AND SMALLER: INSULATION SHALL BE THE FOLLOWING:
a. MINERAL-FIBER, PREFORMED PIPE INSULATION, TYPE I: 1 INCH THICK.2. NPS 1-1/2 AND LARGER: INSULATION SHALL BE THE FOLLOWING:
a. MINERAL-FIBER, PREFORMED PIPE INSULATION, TYPE I: 1-1/2 INCH THICK.4. EXPOSED SANITARY DRAINS, DOMESTIC WATER, DOMESTIC HOT WATER, AND STOPS FOR PLUMBING FIXTURES FOR PEOPLE
WITH DISABILITIES:A. MANUFACTURED PLASTIC WRAPS FOR COVERING PLUMBING FIXTURE HOT- AND COLD-WATER SUPPLIES AND TRAP AND
DRAIN PIPING. COMPLY WITH AMERICANS WITH DISABILITIES ACT (ADA) REQUIREMENTS.5. INDOOR, FIELD-APPLIED JACKET SCHEDULE
A. PIPE FITTINGS EXPOSED AND CONCEALED (FITTINGS ONLY):1. PVC: 20 MILS THICK.
SECTION 221116 - DOMESTIC WATER PIPING1. PROVIDE PIPING LISTED IN ACCORDANCE TO LOCAL AUTHORITIES, UTILITIES AND CODE.2. ABOVEGROUND DOMESTIC WATER PIPING
A. PIPE NPS 2 AND SMALLER:1. HARD COPPER TUBE; CAST- OR WROUGHT-COPPER, SOLDER-JOINT FITTINGS; AND SOLDERED JOINTS.2. HARD COPPER TUBE; COPPER PRESSURE-SEAL-JOINT FITTINGS; AND PRESSURE-SEALED JOINTS.
A. PIPING AND VALVES: 100 PSIG MINIMUM UNLESS OTHERWISE INDICATED.2. PIPES, TUBES, AND FITTINGS
A. STEEL PIPE: ASTM A 53/A 53M, BLACK STEEL, SCHEDULE 40, TYPE E OR S, GRADE B.1. MALLEABLE-IRON THREADED FITTINGS: ASME B16.3, CLASS 150, STANDARD PATTERN.2. WROUGHT-STEEL WELDING FITTINGS: ASTM A 234/A 234M FOR BUTT WELDING AND SOCKET WELDING.3. UNIONS: ASME B16.39, CLASS 150, MALLEABLE IRON WITH BRASS-TO-IRON SEAT, GROUND JOINT, AND THREADED
ENDS.4. FORGED-STEEL FLANGES AND FLANGED FITTINGS: ASME B16.5, MINIMUM CLASS 150, INCLUDING BOLTS, NUTS, AND
GASKETS OF THE FOLLOWING MATERIAL GROUP, END CONNECTIONS, AND FACINGS:a. MATERIAL GROUP: 1.1.b. END CONNECTIONS: THREADED OR BUTT WELDING TO MATCH PIPE.c. GASKET MATERIALS: ASME B16.20, METALLIC, FLAT, ASBESTOS FREE, ALUMINUM O-RINGS, AND SPIRAL-
WOUND METAL GASKETS.d. BOLTS AND NUTS: ASME B18.2.1, CARBON STEEL ABOVEGROUND AND STAINLESS STEEL UNDERGROUND.
5. MECHANICAL COUPLINGS:a. STEEL FLANGES AND TUBE WITH EPOXY FINISH.b. BUNA-NITRILE SEALS.c. STEEL BOLTS, WASHERS, AND NUTS.
3. JOINING MATERIALSA. JOINT COMPOUND AND TAPE: SUITABLE FOR NATURAL GAS.B. WELDING FILLER METALS: COMPLY WITH AWS D10.12/D10.12M FOR WELDING MATERIALS APPROPRIATE FOR WALL
THICKNESS AND CHEMICAL ANALYSIS OF STEEL PIPE BEING WELDED.4. MANUAL GAS SHUTOFF VALVES
A. GENERAL REQUIREMENTS FOR METALLIC VALVES, NPS 2-1/2 AND LARGER: COMPLY WITH ASME B16.38.1. CWP RATING: 125 PSIG.2. FLANGED ENDS: COMPLY WITH ASME B16.5 FOR STEEL FLANGES.3. SERVICE MARK: INITIALS "WOG" SHALL BE PERMANENTLY MARKED ON VALVE BODY.
B. TWO-PIECE, FULL-PORT, BRONZE BALL VALVES WITH BRONZE TRIM: MSS SP-110.1. BODY: BRONZE, COMPLYING WITH ASTM B 584.2. BALL: CHROME-PLATED BRONZE.3. STEM: BRONZE; BLOWOUT PROOF.4. SEATS: REINFORCED TFE; BLOWOUT PROOF.5. PACKING: THREADED-BODY PACKNUT DESIGN WITH ADJUSTABLE-STEM PACKING.6. ENDS: THREADED, FLARED, OR SOCKET AS INDICATED IN "ABOVEGROUND MANUAL GAS SHUTOFF VALVE SCHEDULE"
ARTICLE.7. CWP RATING: 600 PSIG.8. LISTING: VALVES NPS 1 AND SMALLER SHALL BE LISTED AND LABELED BY AN NRTL ACCEPTABLE TO AUTHORITIES
HAVING JURISDICTION.C. BRONZE PLUG VALVES: MSS SP-78.
1. BODY: BRONZE, COMPLYING WITH ASTM B 584.2. PLUG: BRONZE.3. ENDS: THREADED, SOCKET, OR FLANGED AS INDICATED IN "ABOVEGROUND MANUAL GAS SHUTOFF VALVE
SCHEDULE" ARTICLES.4. OPERATOR: SQUARE HEAD OR LUG TYPE WITH TAMPERPROOF FEATURE WHERE INDICATED.5. PRESSURE CLASS: 125 PSIG.6. LISTING: VALVES NPS AND SMALLER SHALL BE LISTED AND LABELED BY AN NRTL ACCEPTABLE TO AUTHORITIES
HAVING JURISDICTION.7. SERVICE: SUITABLE FOR NATURAL-GAS SERVICE WITH "WOG" INDICATED ON VALVE BODY.
6. INDOOR PIPING INSTALLATIONA. ARRANGE FOR PIPE SPACES, CHASES, SLOTS, SLEEVES, AND OPENINGS IN BUILDING STRUCTURE DURING
PROGRESS OF CONSTRUCTION, TO ALLOW FOR MECHANICAL INSTALLATIONS.B. INSTALL PIPING IN CONCEALED LOCATIONS UNLESS OTHERWISE INDICATED AND EXCEPT IN EQUIPMENT ROOMS
AND SERVICE AREAS.C. INSTALL PIPING INDICATED TO BE EXPOSED AND PIPING IN EQUIPMENT ROOMS AND SERVICE AREAS AT RIGHT
ANGLES OR PARALLEL TO BUILDING WALLS. DIAGONAL RUNS ARE PROHIBITED UNLESS SPECIFICALLY INDICATED OTHERWISE.
D. INSTALL NATURAL-GAS PIPING AT UNIFORM GRADE OF 2 PERCENT DOWN TOWARD DRIP AND SEDIMENT TRAPS.E. INSTALL PIPING FREE OF SAGS AND BENDS.F. INSTALL FITTINGS FOR CHANGES IN DIRECTION AND BRANCH CONNECTIONS.G. DRIPS AND SEDIMENT TRAPS: INSTALL DRIPS AT POINTS WHERE CONDENSATE MAY COLLECT, INCLUDING
SERVICE-METER OUTLETS. LOCATE WHERE ACCESSIBLE TO PERMIT CLEANING AND EMPTYING. DO NOT INSTALL WHERE CONDENSATE IS SUBJECT TO FREEZING.1. CONSTRUCT DRIPS AND SEDIMENT TRAPS USING TEE FITTING WITH BOTTOM OUTLET PLUGGED OR CAPPED.
USE NIPPLE A MINIMUM LENGTH OF 3 PIPE DIAMETERS, BUT NOT LESS THAN 3 INCHES LONG AND SAME SIZE AS CONNECTED PIPE. INSTALL WITH SPACE BELOW BOTTOM OF DRIP TO REMOVE PLUG OR CAP.
H. USE ECCENTRIC REDUCER FITTINGS TO MAKE REDUCTIONS IN PIPE SIZES. INSTALL FITTINGS WITH LEVEL SIDE DOWN.
I. CONNECT BRANCH PIPING FROM TOP OR SIDE OF HORIZONTAL PIPING.J. INSTALL UNIONS IN PIPES NPS 2 AND SMALLER, ADJACENT TO EACH VALVE, AT FINAL CONNECTION TO EACH
PIECE OF EQUIPMENT. UNIONS ARE NOT REQUIRED AT FLANGED CONNECTIONS.K. DO NOT USE NATURAL-GAS PIPING AS GROUNDING ELECTRODE.L. INSTALL SLEEVES FOR PIPING PENETRATIONS OF WALLS, CEILINGS, AND FLOORS.
7. VALVE INSTALLATIONA. INSTALL MANUAL GAS SHUTOFF VALVE FOR EACH GAS APPLIANCE AHEAD OF CORRUGATED STAINLESS-STEEL
TUBING, ALUMINUM, OR COPPER CONNECTOR AND AS NOTED ON PLANS.8. PIPING JOINT CONSTRUCTION
A. REAM ENDS OF PIPES AND TUBES AND REMOVE BURRS.B. REMOVE SCALE, SLAG, DIRT, AND DEBRIS FROM INSIDE AND OUTSIDE OF PIPE AND FITTINGS BEFORE ASSEMBLY.C. THREADED JOINTS:
1. THREAD PIPE WITH TAPERED PIPE THREADS COMPLYING WITH ASME B1.20.1.2. CUT THREADS FULL AND CLEAN USING SHARP DIES.3. REAM THREADED PIPE ENDS TO REMOVE BURRS AND RESTORE FULL INSIDE DIAMETER OF PIPE.4. APPLY APPROPRIATE TAPE OR THREAD COMPOUND TO EXTERNAL PIPE THREADS UNLESS DRYSEAL
THREADING IS SPECIFIED.5. DAMAGED THREADS: DO NOT USE PIPE OR PIPE FITTINGS WITH THREADS THAT ARE CORRODED OR
DAMAGED. DO NOT USE PIPE SECTIONS THAT HAVE CRACKED OR OPEN WELDS.D. WELDED JOINTS:
1. CONSTRUCT JOINTS ACCORDING TO AWS D10.12/D10.12M, USING QUALIFIED PROCESSES AND WELDING OPERATORS.
2. BEVEL PLAIN ENDS OF STEEL PIPE.3. PATCH FACTORY-APPLIED PROTECTIVE COATING AS RECOMMENDED BY MANUFACTURER AT FIELD WELDS
AND WHERE DAMAGE TO COATING OCCURS DURING CONSTRUCTION.E. FLANGED JOINTS: INSTALL GASKET MATERIAL, SIZE, TYPE, AND THICKNESS APPROPRIATE FOR NATURAL-GAS
SERVICE. INSTALL GASKET CONCENTRICALLY POSITIONED.9. HANGER AND SUPPORT INSTALLATION
A. INSTALL HANGERS FOR STEEL PIPING, WITH MAXIMUM HORIZONTAL SPACING AND MINIMUM ROD DIAMETERS, TO COMPLY WITH MSS-58, LOCALLY ENFORCED CODES, AND AUTHORITIES HAVING JURISDICTION REQUIREMENTS, WHICHEVER ARE MOST STRINGENT.
B. INSTALL HANGERS FOR CORRUGATED STAINLESS-STEEL TUBING, WITH MAXIMUM HORIZONTAL SPACING AND MINIMUM ROD DIAMETERS, TO COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS, LOCALLY ENFORCED CODES, AND AUTHORITIES HAVING JURISDICTION REQUIREMENTS, WHICHEVER ARE MOST STRINGENT.
C. SUPPORT HORIZONTAL PIPING WITHIN 12 INCHES OF EACH FITTING.D. SUPPORT VERTICAL RUNS OF STEEL PIPING TO COMPLY WITH MSS-58, LOCALLY ENFORCED CODES, AND
AUTHORITIES HAVING JURISDICTION REQUIREMENTS, WHICHEVER ARE MOST STRINGENT.10. CONNECTIONS
A. CONNECT TO UTILITY'S GAS MAIN ACCORDING TO UTILITY'S PROCEDURES AND REQUIREMENTS.B. INSTALL NATURAL-GAS PIPING ELECTRICALLY CONTINUOUS, AND BONDED TO GAS APPLIANCE EQUIPMENT
GROUNDING CONDUCTOR OF THE CIRCUIT POWERING THE APPLIANCE ACCORDING TO NFPA 70.C. INSTALL PIPING ADJACENT TO APPLIANCES TO ALLOW SERVICE AND MAINTENANCE OF APPLIANCES.D. SEDIMENT TRAPS: INSTALL TEE FITTING WITH CAPPED NIPPLE IN BOTTOM TO FORM DRIP, AS CLOSE AS
PRACTICAL TO INLET OF EACH APPLIANCE.11. PAINTING
A. PAINT EXPOSED, INTERIOR METAL PIPING, VALVES, SERVICE REGULATORS, SERVICE METERS AND METER BARS, AND PIPING SPECIALTIES, EXCEPT COMPONENTS, WITH FACTORY-APPLIED PAINT OR PROTECTIVE COATING.1. ALKYD SYSTEM: MPI INT 5.1E.
a. PRIME COAT: ALKYD ANTICORROSIVE METAL PRIMER.b. INTERMEDIATE COAT: INTERIOR ALKYD MATCHING TOPCOAT.c. TOPCOAT: INTERIOR ALKYD FLAT.d. COLOR: GRAY.
12. INDOOR PIPING SCHEDULEA. ABOVEGROUND NATURAL-GAS PIPING SHALL BE ONE OF THE FOLLOWING:
1. STEEL PIPE WITH MALLEABLE-IRON FITTINGS AND THREADED JOINTS.2. STEEL PIPE WITH WROUGHT-STEEL FITTINGS AND WELDED JOINTS.
13. ABOVEGROUND MANUAL GAS SHUTOFF VALVE SCHEDULEA. VALVES FOR PIPE SIZES NPS 2 AND SMALLER SHALL BE ONE OF THE FOLLOWING:
SECTION 221316 - SANITARY WASTE AND VENT PIPING1. MATERIALS
A. HUB-AND-SPIGOT, SERVICE CLASS, CAST-IRON SOIL PIPE AND FITTINGS.B. TYPE DWV COPPER TUBE WITH SOLDER-JOINT DRAINAGE FITTINGS.C. SOLID-WALL PVC PIPE WITH PVC SOCKET FITTINGS (NO PVC PIPING ALLOWED IN RETURN AIR PLENUMS).D. SHIELDED, NONPRESSURE TRANSITION COUPLINGS.
AND SKIRT EXTENDING AT LEAST FROM PIPE, WITH GALVANIZED-STEEL BOOT REINFORCEMENT AND COUNTER FLASHING FITTING.
3. THROUGH-PENETRATION FIRESTOP ASSEMBLIES: LISTED AND LABELED ASSEMBLY OF SLEEVE AND STACK FITTING WITH FIRE STOPPING PLUG. APPROVED UL ASSEMBLY MAY BE PROVIDED.
4. MISCELLANEOUS SANITARY DRAINAGE PIPING SPECIALTIES:A. OPEN DRAINS, SHOP OR FIELD FABRICATED FROM SERVICE CLASS, HUB-AND-SPIGOT, CAST-IRON, SOIL-PIPE
A. COMMERCIAL DRAIN PUMP1. PUMP TYPE: DRAIN.2. 3/8” SOLID HANDLING CAPABILITY.3. PIGGY BACK STYLE ON/OFF FLOAT SWITCH.4. CONSTRUCTION:
1. MOTOR HOUSING: DEEP FINNED POWDER COATED ALUMINUM.2. FASTENERS EXPOSED TO THE LIQUID: STAINLESS STEEL.3. TANK: POLYPROPYLENE.4. MOTOR SHAFT: 300 OR 400 SERIES STAINLESS STEEL.
5. 10 FEET OF MULTICONDUCTOR POWER CORD.6. CSA AND UL APPROVED AUTOMATIC WIDE ANGLE TILT FLOAT SWITCHES.
SECTION 224100 - PLUMBING FIXTURES1. LAVATORIES
A. LAVATORIES: WALL-HUNG, VITREOUS CHINA.2. LAVATORY FAUCETS
A. NSF STANDARD: NSF 372 FOR FAUCET-SPOUT MATERIALS IN CONTACT WITH POTABLE WATER.3. WATER CLOSETS
A. WATER CLOSETS: FLOOR MOUNTED FLUSH TANK TOILET, VITREOUS CHINA, MACERATING SYSTEM.1. RIM CONTOUR: ELONGATED.2. WATER CONSUMPTION: WATER SAVING – 1.28 GPF.3. MACERATING PUMP
1. MATERIAL: PLASTIC.2. TYPE: OPEN FRONT, ELONGATED RIM, WITHOUT COVER.3. HINGE TYPE: SLOW CLOSE.
5. INSTALLATION OF PLUMBING FIXTURES:A. INSTALL PLUMBING FIXTURES LEVEL AND PLUMB, IN ACCORDANCE WITH FIXTURE MANUFACTURERS' WRITTEN
INSTALLATION INSTRUCTIONS, ROUGHING-IN DRAWINGS, AND REFERENCED STANDARDS.B. FASTEN WALL-HANGING PLUMBING FIXTURES SECURELY TO SUPPORTS ATTACHED TO BUILDING SUBSTRATE
WHEN SUPPORTS ARE SPECIFIED, AND TO BUILDING WALL CONSTRUCTION WHERE NO SUPPORT IS INDICATED.C. FASTEN COUNTER-MOUNTING-TYPE PLUMBING FIXTURES TO CASEWORK.D. SECURE SUPPLIES BEHIND WALL OR WITHIN WALL PIPE SPACE, PROVIDING RIGID INSTALLATION.E. INSTALL STOP VALVE IN AN ACCESSIBLE LOCATION IN EACH WATER SUPPLY TO EACH FIXTURE.F. INSTALL TRAP ON FIXTURE OUTLET EXCEPT FOR FIXTURES HAVING INTEGRAL TRAP.G. INSTALL ESCUTCHEONS AT EACH WALL, FLOOR, AND CEILING PENETRATION IN EXPOSED FINISHED LOCATIONS
AND WITHIN CABINETS AND MILLWORK. USE DEEP PATTERN ESCUTCHEONS WHERE REQUIRED TO CONCEAL PROTRUDING PIPE FITTINGS.
H. SEAL FIXTURES TO WALLS, FLOORS, AND COUNTERS USING A SANITARY-TYPE, ONE-PART, MILDEW-RESISTANT, SILICONE SEALANT MATCH SEALANT COLOR TO FIXTURE COLOR.
I. INSPECT EACH INSTALLED FIXTURE FOR DAMAGE. REPLACE DAMAGED FIXTURES AND COMPONENTS.J. TEST FIXTURES TO DEMONSTRATE PROPER OPERATION UPON COMPLETION OF INSTALLATION AND AFTER UNITS
ARE WATER PRESSURIZED. REPLACE MALFUNCTIONING FIXTURES AND COMPONENTS, THEN RETEST. REPEAT PROCEDURE UNTIL ALL UNITS OPERATE PROPERLY.
K. OPERATE AND ADJUST FAUCETS AND CONTROLS. REPLACE DAMAGED AND MALFUNCTIONING FIXTURES, FITTINGS, AND CONTROLS.
L. CLEAN FIXTURES, FITTINGS, AND SPOUT AND DRAIN STRAINERS WITH MANUFACTURERS' RECOMMENDED CLEANING METHODS AND MATERIALS.
M. PROVIDE PROTECTIVE COVERING FOR INSTALLED FIXTURES AND FITTINGS.
A. METAL THICKNESS: 0.050 INCH.B. DRAIN: REAR CENTER.C. SUPPLY FITTINGS: NPS 1/2 CHROME-PLATED BRASS TUBE.D. WASTE FITTINGS: GLECOTRAP GT43; 0.045-INCH THICK TUBULAR BRASS WASTE TO WALL; CONTINUOUS WASTE;
AND WALL ESCUTCHEON(S).2. SINK FAUCETS
A. NSF STANDARD: NSF 372 FOR FAUCET-SPOUT MATERIALS IN CONTACT WITH POTABLE WATER.3. INSTALLATION OF PLUMBING FIXTURES:
A. INSTALL PLUMBING FIXTURES LEVEL AND PLUMB, IN ACCORDANCE WITH FIXTURE MANUFACTURERS' WRITTEN INSTALLATION INSTRUCTIONS, ROUGHING-IN DRAWINGS, AND REFERENCED STANDARDS.
PLUMBING SPECIFICATIONS
SHUT OFF VALVE
500 East Sixth StreetJamestown, NY 14701716-483-3153
labellapc.com
DRAWING NAME:
It is a violation of New York Education Law Article 145 Sec.7209, for any person, unless
acting under the direction of a licensed architect, professional engineer, or land
surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or
land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the
item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the
alteration.
DRAWING NUMBER:
DATE:
ISSUED FOR:
DRAWN BY:
REVIEWED BY:
PROJECT NUMBER:
6/18
/202
1 9
:22:
09
AM
P001
PLUMBING LEGEND SHEET
JLJ
JSN
6-18-21
ISSUED FOR CONSTRUCTION
2192683.01
712 W. EIGHTH STREETJAMESTOWN, NY 14701
EDGEWATER ART HOUSE
THE RESOURCE CENTER
PLUMBING GENERAL NOTES
1 DO NOT SHUT DOWN ANY PLUMBING, FIRE PROTECTION, NATURAL GAS, ORRELATED SYSTEMS WITHOUT BUILDING OWNER'S PRIOR WRITTEN APPROVAL.FOLLOW ALL OWNER REQUIREMENTS AND SHUT DOWN PROCEDURES AS WELL ASALL REQUIREMENTS OF THIS PROJECT.
2 IF REQUIRED, PROVIDE SHUT DOWNS AND TIE-INS DURING OFF HOURS TO AVOIDDISRUPTION OF BUILDING SYSTEMS. COORDINATE ALL SHUT DOWN REQUIREMENTSPRIOR TO SUBMITTING BID (INCLUDE ALL REQUIRED DURING OFF HOURS IN BID).
3 PROVIDE ALL WORK IN COMPLIANCE WITH ALL LOCAL, STATE AND FEDERALCODES. OBTAIN ALL REQUIRED PERMITS.
4 PROVIDE ALL REQUIRED EXCAVATION, BACKFILL AND COMPACTION FOR ALLUNDERGROUND WORK.
5 FIELD VERIFY EXACT LOCATION, DEPTH, COMPOSITION AND CONDITION OF ALLPIPING, VALVES AND SYSTEMS AS REQUIRED FOR WORK OF THE CONTRACT.
6 PROVIDE CUTTING, CORING AND PATCHING OF ALL WALLS, SLABS AND DECKS ASREQUIRED FOR WORK SHOWN. COORDINATE ALL WORK WITH OWNER ANDGENERAL CONTRACTOR AND ALL TRADES.
7 PROVIDE SCHEDULE 40 BLACK STEEL PIPE SLEEVES FOR ALL UNDERGROUNDPIPING PASSING THROUGH OR UNDER FOOTINGS, WALLS, FOUNDATION WALLS,SLABS FLOORS AND/OR UNDERGROUND STRUCTURES. REFER TO THE PROJECTSPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
8 WHERE PIPING IS LOCATED OVER FOOTINGS AND/OR OTHER UNDERGROUNDSTRUCTURES, ROLL DOWN AS REQUIRED TO CONNECT TO SYSTEMS NOTED.PROVIDE ALL REQUIRED OFFSETS, FITTINGS AND CONNECTIONS.
9 PITCH ALL SANITARY, WASTE, AND STORM PIPING AS FOLLOWS: PIPING SMALLERTHAN 3", PITCH AT 2 PERCENT (1/4" PER FOOT) MINIMUM. 3" AND LARGER, PITCHAT 1 PERCENT (1/8" PER FOOT) MINIMUM.
10 CONNECT TO SITE PIPING OUTSIDE BUILDING AS SHOWN. PROVIDE ALL REQUIREDOFFSETS, FITTINGS AND CONNECTIONS. FIELD VERIFY EXACT LOCATION, DEPTHAND COMPOSITION OF SITE SERVICES AND COORDINATE ALL WORK WITH SITECONTRACTOR.
11 COORDINATE ALL VENT TERMINATIONS ABOVE ROOF WITH HVAC CONTRACTOR.ALL VENT TERMINATIONS ABOVE ROOF SHALL BE A MINIMUM 10'-0" AWAY FROMANY HVAC OUTSIDE AIR INTAKE (ROOFTOP UNIT, LOUVER, ETC.).
12 PROVIDE SINGLE HOSE BIBB WITH VACUUM BREAKER (HB) UNDER LAVATORY(S) INALL TOILET ROOMS WITH FLOOR DRAINS. ONE REQUIRED PER ROOM.
13 REFER TO ARCHITECTURAL DRAWINGS AND THE PROJECT SPECIFICATIONS FORANY PROJECT PHASING REQUIREMENTS.
14 THE ENTIRE PLUMBING SYSTEM SHALL BE IN ACCORDANCE WITH THE LATESTEDITION OF THE PLUMBING CODE OF NEW YORK STATE AND LOCAL PLUMBINGINSPECTOR.
15 THE EXISTING PIPING INDICATED ON THESE PLANS SHALL BE VERIFIED IN THE FIELDFOR EXACT LOCATIONS, QUANTITY, AND PIPE SIZES.
16 THE PIPING INDICATED ON THESE PLANS ARE DIAGRAMATIC. ALL WORK SHALL BECOORDINATED WITH ALL OTHER TRADES PRIOR TO INSTALLATION. CONTRACTORSHALL COORDINATE ROUTING OF ALL PIPING WITH EXISTING CONDITIONS ANDSHALL PROVIDE ANY NECESSARY OFFSETS, REROUTING, TEES, ELBOWS, ETC.REQUIRED FOR A COMPLETE AND COORDINATED INSTALLATION.
17 THE CONTRACTOR SHALL OBTAIN AND PAY ALL FEES RELATED TO PERMITTING,INSPECTIONS, TAP-ON FEES, ETC.
18 CONTRACTOR SHALL COORDINATE ANY PLUMBING OR PIPING SYSTEM SHUTDOWNWITH THE OWNER 5 DAYS IN ADVANCE.
19 CONTRACTOR SHALL COORDINATE AND PROVIDE ALL NECESSARY PIPING &PLUMBING FITTINGS, PIPING, MISCELLANEOUS ITEMS REQUIRED FOR A COMPLETEINSTALLATION OF ALL PLUMBING RELATED ITEMS.
20 ALL WORK SHALL BE COORDINATED WITH THE EQUIPMENT VENDORS.
21 THE CONTRACTOR SHALL COORDINATE THE INSTALLATION OF ALL UNDER SLABPIPING WITH EXISTING STRUCTURAL FOUNDATIONS. UNDERGROUND UTILITY
LOCATIONS SHALL BE VERIFIED PRIOR TO ANY WORK BEING PERFORMED.CONTRACTOR SHALL REPAIR OR REPLACE ALL PIPING NOT IN PROPER WORKINGORDER OR DAMAGED DURING INSTALLATION OF THE NEW UNDERSLAB PIPING.
22 ALL PLUMBING & PIPING SYSTEMS SHALL BE SUPPORTED AS REQUIRED BY THESTATE AND LOCAL CODE REQUIREMENTS AND PER MANUFACTURER'SRECOMMENDATIONS.
23 ALL PIPING PENETRATIONS THROUGH NEW, EXISTING WALL, OR FLOOR SHALL BESEALED TO EQUAL THE RATING OF THE NEW, EXISTING WALL OR FLOOR.
24 THE PLUMBING SYSTEM SHALL BE TESTED AS REQUIRED BY STATE AND LOCALCODE OR BY THE REQUIREMENTS OF THE LOCAL PLUMBING INSPECTOR.
25 THE ENTIRE DOMESTIC WATER SYSTEM (EXISTING/NEW) SHALL BE DISINFECTED INACCORDANCE TO THE LOCAL CODE & HEALTH DEPARTMENT REQUIREMENTS.
26 THE BACKFLOW PREVENTION DEVICE SHALL BE INSTALLED PER STATE AND LOCALCODE & PER AUTHORITY HAVING JURISDICTION REQUIREMENTS.
27 ALL (VTR'S) VENT THRU ROOF PENETRATIONS INDICATED ON PLANS AREPRELIMINARY. FINAL LOCATIONS SHALL BE COORDINATED WITH ALL TRADES. ALL
VTR'S SHALL BE A MINIMUM OF 10'-0" FROM ALL FRESH AIR INTAKE OPENINGS.
28 CONTRACTOR SHALL INSULATE ALL PLUMBING PIPING PER SPECIFICATION.
Revisions
NO: DATE: DESCRIPTION:
4
P101
3" SAN (E) (UG)
4" SAN (E)
CO (E)
1" P
D
2" P
D
1 1/2" V
1" PD
2" P
D
1 1
/2"
V2
" V
2" PD
2" V UP TO 3"
VTR
LT-1
LAV-1 WC-1
SK-1
US-1
3 4
5
6
2
P-1
1
1"
1"
1/2
"1
/2"
1/2"3/4"1/2"
1/2"
1 1/2" SAN
3/4
"
3/4
"
1/2"
1/2"
1/2
"
1/2
"
7
ART CLASSROOM02
ELEC.01C
JANITOR01B
TOILET03
SHOP/DISPLAY01
STORAGE01A
PASSAGE04
KILN05
STORAGE05A
STORAGE04K
LAUNDRY04I
CORRIDOR02A
1/2"
1/2"
1"
1" 1 1/2" W
WCO (E)
8
1
2
3
3
3
3 3
4
4
EWS-1
5
1ST FLOOR PLAN0' - 0"
ART HOUSE-3' - 0"
SK-1
US-1
P-1
2" P
D
2"
V
1/2"
DC
W
1/2"
DH
W
1/2"
DC
W
1/2"
DH
W
SOLIDS INTERCEPTOR
(TYP)
1 1/2" W 2" W
EWS-1
SEAT
GRINDER AND PUMP
SIDE INLET (TYP BOTH SIDES)
1-1/2" V AND 1" PD
EXTENSION PIPE
WC-1
FINISHED FLOOR
TOILET03
JANITOR01B
1 1/2" W FROM LT-1
1/2" DCW
1" PD
1 1/2" V (BEHIND)
FLOOR
WALL WALL
V
CONNECT WASTE PIPING TO ADJACENT MACERATING TOILET
1-1/2"
P-TRAP W/CO
LAVATORY
FLOOR MOUNTED LAVATORY SUPPORTFOR CONCEALED ARM
1/2" DCW1/2" DHW
STOPVALVE TYP.
1-1/2"
1-1/2"
1-1/2"
MIXING VALVE
NOTES:1. PROVIDE TRAP GUARD
INSULATING KIT.2. PIPING TO BE IN
HEATED SPACE.
1/2" THERMOSTATICTEMPERING VALVE (TYP)
1/2" TW
1/2" CW SUPPLY1/2" HW SUPPLY
1-1/4" O.D. TAILPIECE
DHR
DHW
DCW
OMEGA THERMALBALANCE VALVE, 0.5GPM MAX.
NOTE: HOT WATER RECIRCULATION PIPING SHALL CONNECT TODOMESTIC HOT WATER LINE WITHIN 2'-0" OF FIXTURE CONNECTION.
SEE PLANS FOR PIPE SIZING.
1-1/2" TRAP SINK
WASTELATERAL
1/2" CW1/2" HW
EXTEND 1/2" HW, 1/2" CW AND 1-1/2"VENT ABOVE CEILING AND CONNECT TONEAREST ACTIVE MAIN.
STOPVALVE TYP.
CABINET
PIPE INSULATION-UPPER HALFOF PIPE
INSERT-LOWER HALF OF PIPE
TYPE 40 PROTECTION SHIELD
HANGER ROD W/ JAM NUT
TYPE 1 CLEVIS HANGER
FAUCET
FINISHED FLOOR
UTILITY SINK US-1
1-1/2" SANITARYPIPING
1-1/2" WASTE DN TO MAIN
1/2" HW AND CW PIPING(RUN BESIDE EACHOTHER IN WALL)
WALL
COMMERCIAL DRAINAGE PUMP SCHEDULE
TAG SERVICE LOCATION GPM@FT. HD.PIPE CONNECTION SIZE MOTOR MANUFACTURER
AND MODELNOTES
INLET OUTLET VENT HP RPM FLA VOLT-PH-HZ
P-1ART CLASSROOM
SINKSART CLASSROOM
0212 GPM @29.5 FT. HD.
2" 2" 2" 1/2 3450 7.3 115-1-60LIBERTY PUMPS
INC 405/A1,2,3,4,5
NOTES:
1. FACTORY PRE-ASSEMBLED.
2. PROVIDE WITH 10 FOOT POWER CORD W/GROUND PLUG.
3. FULLY AUTOMATIC OPERATION.
4. PROVIDE STANDARD ALARM.
5. PROVIDE CHECK VALVE.
MANUAL SHUT-OFF VALVE (GAS COCK)WITH AN 1/8" N.P.T. PLUGGED TAPPINGACCESSIBLE FOR TEST GAGECONNECTION TO BE INSTALLEDUPSTREAM OF THE GAS SUPPLYCONNECTION TO THE APPLIANCE
GROUND JOINT UNION (TYP.)
TO EQUIPMENT/ CONTROLS
DIRT LEG
DIRT LEG MINIMUM LENGTH 3" OR 6 PIPE DIAMETERS, WHICH EVER IS GREATER(OPTION 1 CONNECTION)
TEE W/PLUG FORTEST GAGE
GAS SERVICE RATEDFLEX HOSE
OPTION 1:HORIZONTAL GAS PIPE SUPPLY DOWN TO APPLIANCE CONNECTION
OPTION 2:HORIZONTAL GAS PIPE SUPPLY UP TO APPLIANCE CONNECTION
PIPE CAPDIRT LEG MINIMUM LENGTH
3" OR 6 PIPE DIAMETERS, WHICH EVER IS GREATER(OPTION 2 CONNECTION)
TOILET03
SHOP/DISPLAY01
STORAGE01A
PASSAGE04
KILN05
STORAGE05A
STORAGE04K
LAUNDRY04I
CORRIDOR02A
1 1
/4"
NG
3/4" NG
3/4" NG
AHU (SEE MECHANICAL PLANS, TYP)
PROVIDE CONNECTION TO EXISTING GAS SERVICE
9
9
EYEWASH/DRENCH HOSE
1/2" DCW1/2" DHW
1/2" DTW
ASSE 1071COMPLIANTTHERMOSTATICMIXING VALVE
PROVIDE 1-3/8"HOLE IN DECK
1" IPS MOUNTINGSHANK WITH
LOCKNUT
8' HIGHPRESSURE
REINFORCED PVCHOSE
INTEGRAL DUALCHECK VALVE
500 East Sixth StreetJamestown, NY 14701716-483-3153
labellapc.com
DRAWING NAME:
It is a violation of New York Education Law Article 145 Sec.7209, for any person, unless
acting under the direction of a licensed architect, professional engineer, or land
surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or
land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the
item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the
alteration.
DRAWING NUMBER:
DATE:
ISSUED FOR:
DRAWN BY:
REVIEWED BY:
PROJECT NUMBER:
6/18
/202
1 9
:22:
09
AM
P101
PLUMBING PLAN
JLJ
JSN
6-18-21
ISSUED FOR CONSTRUCTION
2192683.01
712 W. EIGHTH STREETJAMESTOWN, NY 14701
EDGEWATER ART HOUSE
THE RESOURCE CENTER
1/4" = 1'-0"P101
1 PLUMBING PLAN1/2" = 1'-0"P101
4 ART CLASSROOM SINK AREA ELEVATION
N
PLUMBING FIXTURE SCHEDULE
MARK TRIM COLD HOT SAN/W VENT SUPPORT MANUFACTURER MODEL NOTES
WC-1 A 1/2" -- 1" 1-1/2" FLOOR LIBERTY PUMPS ASCENT II 1
LAV-1 B 1/2" 1/2" 1-1/2" 1-1/2" WALL AMERICAN STANDARD 0355.012 --
SK-1 D 1/2" 1/2" 1-1/2" 1-1/2" DROP-IN ELKAY LRAD312255 --
US-1 E 1/2" 1/2" 1-1/2" 1-1/2" FLOOR REGENCY 600S13624B --
EWS-1 F 1/2" 1/2" -- -- COUNTER GUARDIAN G5022BP --
NOT TO SCALEP101
9 MACERATING TOILET DETAIL
NOT TO SCALEP101
6 LAVATORY DETAIL
NOT TO SCALEP101
11 LAVATORY PIPING DETAILNOT TO SCALEP101
10 SINK COUTERTOP DETAIL
NOT TO SCALEP101
8 PIPE HANGER DETAIL
NOT TO SCALEP101
5 UTILITY SINK DETAIL
TRIMA. EXTRA HEAVY DUTY SEAT, OPEN FRONT, WHITE ROUND WITH SELF SUSTAINING STAINLESS STEEL CHECK HINGES, SIMILAR TO BEMIS MODEL 1655 SSC.
CHROME PLATED CAST BRASS SUPPLIES WITH LOOSE KEY ANGLE STOPS WITH SET-SCREW ESCUTCHEON AND RISERS SIMILAR TO McGUIRE MODEL LF2166CCLK. PROVIDE FLUSH HANDLE ON OPEN SIDE OF FIXTURE PER ADA REQUIREMENTS.
B. CHROME PLATED BRASS, DECK MOUNTED, ELECTRONIC SENSOR, 0.5 GPM VANDAL RESISTANT NON-AERATED, SIMILAR TO T&S BRASS MODEL EC-3104-VF5-TMV. ASSE 1070 TEMPERATURE LIMITING VALVE, SIMILAR TO POWERS MODEL LFG480. CHROME PLATED CAST BRASS GRID DRAIN WITH 1-1/4" OFFSET TAILPIECE, SIMILAR TO McGUIRE MODEL 155WC. 1-1/4" x 1-1/2" CHROME PLATED CAST BRASS P-TRAP WITH CLEANOUT PLUG CPCB TUBING TO WALL AND SET-SCREW ESCUTCHEON, SIMILAR TO McGUIRE MODEL 8902. CHROME PLATED CAST BRASS SUPPLIES WITH LOOSE KEY ANGLE STOPS WITH SET-SCREW ESCUTCHEON AND RISERS SIMILAR TO McGUIRE MODEL 165LK. PROVIDE ADA COMPLIANT TRAP AND SUPPLY COVERING FOR REQUIRED FIXTURES, SIMILAR TO "PROWRAP".
C. CHROME PLATED, 4" CENTER SET BRASS FAUCET, 7" SWING SPOUT WITH HOSE END, SIMILAR TO MUSTEE 93.600.D. DECK MOUNTED CHROME PLATED CAST BRASS, MANUAL FAUCET, 8" FIXED CENTERS, 8-3/4" TUBULAR TYPE SWING SPOUT WITH 1.5 GPM AERATOR, ADA
COMPLIANT LEVER HANDLE OPERATION. SIMILAR TO MOEN 8799. STRAINER SHALL BE 304 STAINLESS BASKET AND BODY WITH FLEX-STEM AND RUBBER STOPPER WITH OFFSET CHROME PLATED CAST BRASS TAILPIECE, SIMILAR TO JUST MODEL J-35. CLAY/PLASTER SOLID INTERCEPTOR TRAP, SIMILAR TO GLECO TRAP GT43. CHROME PLATED CAST BRASS SUPPLIES WITH LOOSE KEY ANGLE STOP AND SET-SCREW ESCUTCHEON.
E. BACKSPLASH MOUNTED CHROME PLATED CAST BRASS, MANUAL FAUCET, 8" FIXED CENTERS, 12" TUBULAR TYPE SWING SPOUT WITH 2.2 GPM AERATOR, ADA COMPLIANT LEVER HANDLE OPERATION. SIMILAR TO T&S B-2463. STRAINER SHALL BE 304 STAINLESS BASKET AND BODY WITH FLEX-STEM AND RUBBER STOPPER WITH OFFSET CHROME PLATED CAST BRASS TAILPIECE, SIMILAR TO JUST MODEL J-35. CLAY/PLASTER SOLID INTERCEPTOR TRAP, SIMILAR TO GLECO TRAP GT43. CHROME PLATED CAST BRASS SUPPLIES WITH LOOSE KEY ANGLE STOP AND SET-SCREW ESCUTCHEON.
F. ASSE 1071 COMPLIANT THERMOSTATIC MIXING VALVE. INLINE DUAL CHECK BACKFLOW PREVENTER INSTALLED ON INLET OF HOSE.
PROVIDE DCW, DHW, AND DHR CONNECTION TO EXISTING SERVICES.
PROVIDE LT-1 AND ALL ASSOCIATED ACCESSORIES. PROVIDE 1-1/2" W FROM FIXTURE TO SIDE INLET OF WC-1 PUMP. PROVIDE 1/2" DCW AND DHW DOWN TO FIXTURE FROM ABOVE.
PROVIDE LAV-1 AND ALL ASSOCIATED ACCESSORIES. PROVIDE 1-1/2" W FROM FIXTURE TO SIDE INLET OF WC-1 PUMP. PROVIDE 1/2" DCW AND DHW DOWN TO FIXTURE FROM ABOVE.
PROVIDE WC-1 AND ALL ASSOCIATED ACCESSORIES. PROVIDE MACERATING PUMP ON OPPOSITE WALL IN LOCATION SHOWN. INSTALL WATER CLOSET, PUMP, AND ALL ASSOCIATED ACCESSORIES PER MANUFACTURER RECOMMENDATIONS. PROVIDE 1/2" DCW TO WATER CLOSET. PROVIDE 1" PD AND 1-1/2" V UP FROM PUMP.
PROVIDE SK-1 AND ALL ASSOCIATED ACCESSORIES. PROVIDE 1-1/2" W FROM FIXTURE TO P-1 PER DETAIL. PROVIDE 1/2" DCW AND DHW DOWN TO FIXTURE FROM ABOVE. PROVIDE 1/2" DTW TO EWS-1 PER DETAIL.
PROVIDE US-1 AND ALL ASSOCIATED ACCESSORIES. PROVIDE 1-1/2" W FROM FIXTURE TO P-1 PER DETAIL. PROVIDE 1/2" DCW AND DHW DOWN TO FIXTURE FROM ABOVE.
PROVIDE P-1 AND ALL ASSOCIATED ACCESSORIES. INSTALL UNDER COUNTER PER MANUFACTURER RECOMMENDATIONS. PROVIDE 2" PD AND V UP FROM PUMP.
CONNECT PUMP DISCHARGE TO TOP OF SANITARY MAIN PER PLUMBING CODE.
PROVIDE CONNECTION TO FURNACE WITH SHUTOFF VALVE, DRIP LEG, AND UNION.
1
2
3
4
5
6
7
8
REMOVAL KEY NOTES:
REMOVE EXISTING SANITARY LINE BACK TO EXISTING WALL. PROVIDE WALL CLEANOUT AT WALL.
REMOVE EXISTING GAS LINE FROM EXISTING UNIT HEATER BACK TO MAIN AND CAP.
REMOVE DCW LINES, HOSE BIBS, AND ASSOCIATED ACCESSORIES BACK TO MAIN AND CAP.
REMOVE EMERGENCY EYEWASH, TURN OVER TO OWNER. REMOVE DOMESTIC COLD WATER PIPING, WASTE PIPING, AND ALL ASSOCIATED ACCESSORIES. PATCH WALLS TO MATCH EXISTING.