IMMEDIATE SIMPLIFIED STABILIZE PROVISIONAL DIRECT by INTRA-LOCK ® IMMEDIATE LOAD SIMPLIFIED PROCEDURE STABILIZE DENTURES PROVISIONAL PROSTHETICS DIRECT PLACEMENT The REAL Mini Implant The REAL Mini Implant
IMMEDIATE
SIMPLIFIED
STABILIZE
PROVISIONAL
DIRECT
by INTRA-LOCK®
IMMEDIATELOAD
SIMPLIFIED PROCEDURE
STABILIZEDENTURES
PROVISIONALPROSTHETICS
DIRECTPLACEMENT
The REAL Mini ImplantThe REAL Mini Implant
ENGINEERED EVOLUTION.
Polished Collar
SharpApical
GuidingPoint
Mini Drive-Lock™ Surgical Placement SystemMini Drive-Lock™ Surgical Placement System
• Ease of Delivery and Insertion• DIRECT DELIVERY PACKAGE • INSTRUMENTATION FOR LINEAR PATH OF INSERTION
MDL Implants were designed to take advantage of the Drive-Lock™ System which ensures ContraAngle delivery and placement is fluid, economic in motion and predictable. It allows the MDL implantto be removed from its sterile vial, transferred directly to the surgical site and to initiate the self- tappingaction. A Drive-Lock™ Adapter mates with a surgical ratchet wrench for final seating. This ratchet adaptercan be used by hand and also mates with an optional Round Hand Driver to provide greater initialtorque and enhanced tactile sensation. All Drive-Lock™ instruments are designed to promote a linear path of insertion.
• Maximum Self-Threading Capabilities• SHARP APICAL GUIDING POINT • OPTIMUM THREAD PITCH • PROFILED FOR STABILITY • ENGINEERED FOR STRENGTH
MDL’s sharp apical guiding point initiates the self-tapping process, even in the densest bone. Unlikeconventional sized implants, mini implants rely on the viscoelastic nature of bone tissue. They functionvery much like orthopedic fixation screws. Mini implant surgical protocol does not require anosteotomy site, just a pilot hole through the cortical bone. Therefore, the implant must be able topenetrate the cortical plate, cut its way through the alveolar bone with maximum ease and efficiency,forcibly wedging itself into place. Its thread pitch and wedge profile permits intimate contact betweenthe bone and implant surface ensuring initial stability and encouraging immediate load success. MDL’s profile is also configured to provide maximum strength where the highest forces are generated.
• Soft Tissue and Prosthetic Interface• POLISHED COLLAR • ACHIEVES OPTIMUM IMPLANT DEPTH
MDL Implants are designed with a polished collar in order to optimize the soft tissue response to theimplant surface. All Drive-Lock™ instrumentation seats over the O-Ball abutment precisely mating withthe top of the collar. This ensures that depth of implant placement is accurately attained when theshoulder of the collar is flush with (the height of) the surrounding gingiva. MDL’s are provided with O-Rings encased in Metal Housings ready to be processed in a denture. A special abutment thatcements over the O-Ball assembly has been designed for temporary fixed bridges. This abutmentfunctions as an impression coping and can be laboratory machined for parallelism.
Intra-Lock™ has elevated the engineering and delivery system of the Mini Dental Implant.
•
•
Self-Limiting Depth Design
•
Profiled for Strengthand Stability
•
Optimum Thread Pitch and Surface Finish
•
(Patent Pending)
Ligh
t, r
epea
ted,
inte
rmed
iate
, ver
tica
l in
tro
duct
ion
of
the
1.2m
m e
xter
nal
ly ir
riga
ted
Pil
ot D
rill
bre
ach
es
the
gin
giva
l ti
ssu
e an
d pe
rio
steu
m.
MD
L’s
are
rem
ove
d fr
om
th
eir
ster
ile
vial
an
d tr
ansf
erre
d di
rect
ly t
o t
he
surg
ical
sit
e vi
a a
Dri
ve-L
ock
Co
ntr
a-A
ngl
e At
tach
men
t th
at s
nap
s o
ver
the
O-b
all
asse
mbl
y.
The
use
of
an e
lect
ric
mot
or
wit
h a
torq
ue
lim
itin
g fe
atu
re s
et t
o 3
5Ncm
is r
eco
mm
ende
d.
MD
L’s
shar
p ap
ical
gli
din
gpo
int
init
iate
s th
e se
lf-
tapp
ing
acti
on
; th
read
ing
and
expa
ndi
ng
the
bon
e at
th
esa
me
tim
e. In
pre
para
tio
n f
or
the
fin
al s
eati
ng,
Th
eh
andp
iece
wil
l st
all
wh
en t
he
torq
ue
lim
itin
g va
lue
of
35N
cm is
rea
ched
.
Dri
llin
g de
pth
isap
prox
imat
ely
on
e-th
ird
the
len
gth
of
the
impl
ant
wit
hca
re t
aken
to
bre
ach
th
eco
rtic
al p
late
.
MD
L Im
plan
t D
entu
re S
tabi
lizat
ion
Dri
ve-L
ock
Ada
pter
mat
es w
ith
a S
urg
ical
Rat
chet
Wre
nch
fo
r th
e fi
nal
sea
tin
g ph
ase.
Th
is R
atch
et A
dapt
er
can
be
use
d by
han
d an
d al
so m
ates
wit
h a
n o
ptio
nal
R
ou
nd
Han
d D
rive
r to
pro
vide
gre
ater
init
ial
torq
ue
and
enh
ance
d ta
ctil
e se
nsa
tio
n.
Sm
all
incr
emen
tal
turn
s, w
ith
a p
ause
bet
wee
nea
ch t
urn
to
tak
e ad
van
tage
of
the
visc
oel
asti
cn
atu
re o
f th
e bo
ne
acco
mpl
ish
es f
inal
sea
tin
g.Th
e co
rrec
t de
pth
of
an M
DL
impl
ant
isac
hie
ved
wh
en t
he
wre
nch
ada
pter
is f
lush
wit
h t
he
surr
ou
ndi
ng
gin
giva
l ti
ssu
e.
They
sn
ap o
ver
th
e O
-Bal
las
sem
bly
read
y to
be
pro
cess
edin
a d
entu
re. A
spe
cial
abu
tmen
tth
at c
emen
ts o
ver
the
O-B
all
asse
mbl
y h
as b
een
des
ign
ed f
or
tem
pora
ry f
ixed
bri
dges
MD
L’s
are
pro
vide
d w
ith
O-R
ings
en
case
d in
Met
al H
ou
sin
gs.
MDL Temporary Abutment Protocol
1. Surgical Placement - MDL Implants aresurgically placed in position.
2. Impression Copings - MDL Abutments slideover O-Balls and serve as impression copings.
3. Impression - MDL Abutments are picked up inan impression tray.
4. MDL Analogs - Analogs are placed into theMDL Abutments in the impression.
5. MDL Abutment Preparation - A laboratorymilling machine prepares the abutments toachieve parallelism.
6. Temporary Fixed Bridges -The Abutments arecemented over the MDL Implants with resincement. A metal reinforced bridge (for rigidity)is then cemented on the abutments withtemporary cement.
Surgical PlacementSurgical Placement Impression CopingsImpression Copings
ImpressionImpression MDL AnalogsMDL Analogs
MDL Abutment PreparationMDL Abutment Preparation Temporary Fixed BridgesTemporary Fixed Bridges
3
1
5
2
4
6
IMPLANTS
DRILL
INSTRUMENTS FOR INSERTION OF IMPLANTS
SURGICAL BOX
PROSTHETIC COMPONENTS
Intra-Lock International, Inc.1200 North Federal Highway, Suite 200Boca Raton, Florida 33432www.intra-lock.com • [email protected]
0499 • © Copyright 2003, Intra-Lock® System International • S4EN-09-01
MDI™ Mini Drive-Lock implants, 2.0mm Diameter
Length 10mm 13mm 15mm 18mmRef No. MDL10 MDL13 MDL15 MDL18
Mini Drive-Lock Pilot Twist Drill
1.2mm diameter..........................................................................MDLPD
Mini Drive-Lock Contra Angle Driver
Standard Contra Angle..............................................................MDLCAD
Mini Drive-Lock Ratchet Driver
Use as an MDL Hand Driver or with a Surgical Ratchet Wrench ............................................................MDLRD
Mini Drive-Lock Manual Wrench
Connects to Mini Drive-Lock Ratchet Driver ............................MDLMW
Surgical Ratchet Wrench
With square connection, 4x4mm, autoclavable ..................................SR
Mini Drive-Lock Surgical Box
Accommodates all MDL surgical instrumentsfor MDL Implant delivery and placement ....................................MDLSK
Mini Drive-Lock Laboratory Analog
Replicates the MDL Implant and abutment..................................MDLLA
Mini Drive-Lock Metal Housings with O-Rings
O-Rings encapsulated in metal housings for ease of placement andreplacement ..............................................................................MDLMH
MDL O-Ring Replacements
Quantity of 10 ............................................................................MDLOR
Mini Drive-Lock Cementable Abutment
Cements over O-Ball assembly for temporary fixed bridges ........MDLSA
MDLCAD
MDLMW
MDLRD
SR
MDLLA
MDLMH
MDLSA
MDLOR
CE