The Basic Principles of Ophthalmic Ultrasound Devices

ORBIS International

Cheng Xiao Ming

Page 2: The Basic Principles of Ophthalmic Ultrasound · PDF fileThe Basic Principles of Ophthalmic Ultrasound Devices ... Basic Structure of an Ultrasound Transducer ... The transducer sweeps

Basics of Ultrasonography

Ultrasound Waves are acoustic waves that have frequencies greater than 20 KHz.

The audible range to humans is 60 Hz to 20 KHz.

Page 3: The Basic Principles of Ophthalmic Ultrasound · PDF fileThe Basic Principles of Ophthalmic Ultrasound Devices ... Basic Structure of an Ultrasound Transducer ... The transducer sweeps

Basics of Ultrasonography

Sound Waves

Sound is a mechanical wave (pressure wave) which is created by a vibrating object.

Page 4: The Basic Principles of Ophthalmic Ultrasound · PDF fileThe Basic Principles of Ophthalmic Ultrasound Devices ... Basic Structure of an Ultrasound Transducer ... The transducer sweeps

Basics of UltrasonographySound Waves

• The energy of vibration is transported through the mediamedia (for example: air, water, human tissue…).

Page 5: The Basic Principles of Ophthalmic Ultrasound · PDF fileThe Basic Principles of Ophthalmic Ultrasound Devices ... Basic Structure of an Ultrasound Transducer ... The transducer sweeps

Basics of Ultrasonography

Tfl.gif

Sound Waves

• Sound is propagated as a longitudinal wave.

• Longitudinal wave consists of alternating compressions and rarefactions of molecules as the wave passes through a medium.

Page 6: The Basic Principles of Ophthalmic Ultrasound · PDF fileThe Basic Principles of Ophthalmic Ultrasound Devices ... Basic Structure of an Ultrasound Transducer ... The transducer sweeps

Basics of UltrasonographySound Waves

The sound wave is characterized by:velocity (m/s):

frequency (Hz):

wavelength (m):

TTime

P

the speed of propagation of the wave.

number of complete cycles per unit of time.the distance traveled by one cycle.

Velocity = Wavelength x Frequency

Page 7: The Basic Principles of Ophthalmic Ultrasound · PDF fileThe Basic Principles of Ophthalmic Ultrasound Devices ... Basic Structure of an Ultrasound Transducer ... The transducer sweeps

Basics of Ultrasonography

Sound Waves

Velocity: the speed of sound propagation

Material Velocity (m/s)Air 330Water 1480Blood 1500Aqueous and vitreous 1532Soft tissue 1540Clear lens 1640Bone 3500

Density of Material

Increasing

Page 8: The Basic Principles of Ophthalmic Ultrasound · PDF fileThe Basic Principles of Ophthalmic Ultrasound Devices ... Basic Structure of an Ultrasound Transducer ... The transducer sweeps

Basics of Ultrasonography

Reflection of Sound Wave

Reflected sound waves are produced by acoustic interfaces that have different acoustic impedances.

Acoustic Interface:

Acoustic Impedance of a Medium:

is created at the junction of two media ( for example: air and rock, soft-tissue and bone…).

is a measure of the efficiency with which sound propagates in the material.

Acoustic Impedance = Sound Velocity Acoustic Impedance = Sound Velocity xx Medium Density Medium Density

Page 9: The Basic Principles of Ophthalmic Ultrasound · PDF fileThe Basic Principles of Ophthalmic Ultrasound Devices ... Basic Structure of an Ultrasound Transducer ... The transducer sweeps

Basics of Ultrasonography

Acoustic Impedance for Different Materials

Material Acoustic Impedance(106 Rayls)

Air 0.0004

Fat 1.38

Water 1.48

Liver 1.65

Muscle 1.70

Bone 7.80

Page 10: The Basic Principles of Ophthalmic Ultrasound · PDF fileThe Basic Principles of Ophthalmic Ultrasound Devices ... Basic Structure of an Ultrasound Transducer ... The transducer sweeps

Basics of Ultrasonography

Propagation of Sound Wave at a Perpendicular Surface

Reflected Sound

Media BMedia A

Incident Sound

Acoustic Interface

Page 11: The Basic Principles of Ophthalmic Ultrasound · PDF fileThe Basic Principles of Ophthalmic Ultrasound Devices ... Basic Structure of an Ultrasound Transducer ... The transducer sweeps

Basics of Ultrasonography

Propagation of Sound Wave at a Non-perpendicular Surface

Reflected Sound

Media BMedia A

Refracted Sound

Incident Sound

Page 12: The Basic Principles of Ophthalmic Ultrasound · PDF fileThe Basic Principles of Ophthalmic Ultrasound Devices ... Basic Structure of an Ultrasound Transducer ... The transducer sweeps

Basics of Ultrasonography

Propagation of Sound Wave at a Irregular Surface

Reflected Sound

Media BMedia A

Incident Sound

Acoustic Interface

Deviated Sound

Page 13: The Basic Principles of Ophthalmic Ultrasound · PDF fileThe Basic Principles of Ophthalmic Ultrasound Devices ... Basic Structure of an Ultrasound Transducer ... The transducer sweeps

Basics of UltrasonographyPiezoelectric Effects

ForceElectrical Charges

Piezoelectric Crystal

Piezoelectric Crystal

Mechanical Deformation

ForceElectrical Charges

Mechanical Deformation

+ + + +

- - - -

+ + + +

- - - -

Natural quartz, lead zirconate titanate ….

Page 14: The Basic Principles of Ophthalmic Ultrasound · PDF fileThe Basic Principles of Ophthalmic Ultrasound Devices ... Basic Structure of an Ultrasound Transducer ... The transducer sweeps

Basics of UltrasonographyPiezoelectric Effects

Piezoelectric Crystal

Piezoelectric Crystal

Page 15: The Basic Principles of Ophthalmic Ultrasound · PDF fileThe Basic Principles of Ophthalmic Ultrasound Devices ... Basic Structure of an Ultrasound Transducer ... The transducer sweeps

Basics of Ultrasonography

Focus Zone

Basic Structure of an Ultrasound Transducer

Crystal

Acoustic Coupling Material

Electrical

Pulses

Page 16: The Basic Principles of Ophthalmic Ultrasound · PDF fileThe Basic Principles of Ophthalmic Ultrasound Devices ... Basic Structure of an Ultrasound Transducer ... The transducer sweeps

Basics of Ultrasonography

Input Electrical Pulses

Ultrasound

Transducer

Sound Wave

Echoes

Output Electrical Pulses

Page 17: The Basic Principles of Ophthalmic Ultrasound · PDF fileThe Basic Principles of Ophthalmic Ultrasound Devices ... Basic Structure of an Ultrasound Transducer ... The transducer sweeps

Basics of Ultrasonography

The greater the difference in the acoustic impedance of the two media that produced the interface, the stronger the reflection of the ultrasound wave.

Medium A

Medium CMedium A

Medium B

Sound

source IC > IB

Page 18: The Basic Principles of Ophthalmic Ultrasound · PDF fileThe Basic Principles of Ophthalmic Ultrasound Devices ... Basic Structure of an Ultrasound Transducer ... The transducer sweeps

Ophthalmic Ultrasound Medium A

Medium A

Resolution of Ultrasound Imaging

Frequency of Ultrasound

Depth of Penetration

Resolution of Ultrasound Imaging

Frequency of Ultrasound

Depth of Penetration

Page 19: The Basic Principles of Ophthalmic Ultrasound · PDF fileThe Basic Principles of Ophthalmic Ultrasound Devices ... Basic Structure of an Ultrasound Transducer ... The transducer sweeps

Ophthalmic Ultrasound

Ophthalmic ultrasound uses frequencies ranging from 6 to 50 MHz (1MHz=1 million cycles per second)

Type of Ultrasound Device FrequencyA-Scan 6~15 MHz

Ultrasound Biometry 6~15 MHz

B-Scan 8~20 MHz

UBM (Ultrasound Bio-microscopy) 30~50 MHz

Page 20: The Basic Principles of Ophthalmic Ultrasound · PDF fileThe Basic Principles of Ophthalmic Ultrasound Devices ... Basic Structure of an Ultrasound Transducer ... The transducer sweeps

Ophthalmic UltrasoundAbsorption and Attenuation of Ultrasound

Energy in the Tissues

Causes of Loss Energy:

•Beamwidth loss ( a = 1/D2 )

•Absorption loss ( Tissue Acoustic Impedance )

•Scattering loss

Page 21: The Basic Principles of Ophthalmic Ultrasound · PDF fileThe Basic Principles of Ophthalmic Ultrasound Devices ... Basic Structure of an Ultrasound Transducer ... The transducer sweeps

Ophthalmic Ultrasound

Basics of Ultrasound Devices

Pulse

Generator

Receiver

AmplifierSignal

ProcessorOutput

Device

Transducer

Page 22: The Basic Principles of Ophthalmic Ultrasound · PDF fileThe Basic Principles of Ophthalmic Ultrasound Devices ... Basic Structure of an Ultrasound Transducer ... The transducer sweeps

Ophthalmic UltrasoundPulse Ultrasound System

ReceiveTransmit Transmit

Page 23: The Basic Principles of Ophthalmic Ultrasound · PDF fileThe Basic Principles of Ophthalmic Ultrasound Devices ... Basic Structure of an Ultrasound Transducer ... The transducer sweeps

Ophthalmic UltrasoundTime-Gain Compensation

Depth

Reflection

Amplitude

Time

Gain

Page 24: The Basic Principles of Ophthalmic Ultrasound · PDF fileThe Basic Principles of Ophthalmic Ultrasound Devices ... Basic Structure of an Ultrasound Transducer ... The transducer sweeps

Ophthalmic Ultrasound

– A scan

– biometry

– B Scan

– UBM

Ultrasound Scan Modes

Page 25: The Basic Principles of Ophthalmic Ultrasound · PDF fileThe Basic Principles of Ophthalmic Ultrasound Devices ... Basic Structure of an Ultrasound Transducer ... The transducer sweeps

Anterior and Posterior surface of Cornea

Anterior surface of lensPosterior surface of lens

Retina

ScleraVitreous

Anterior Chamber

A-SCAN

Page 26: The Basic Principles of Ophthalmic Ultrasound · PDF fileThe Basic Principles of Ophthalmic Ultrasound Devices ... Basic Structure of an Ultrasound Transducer ... The transducer sweeps

A-SCAN Biometry

A-Scans are used to measure the axial length of the eye for determining the proper power of the intraocular lens to be implanted. Typical axial length measurements are from 21-26 mm.

Page 27: The Basic Principles of Ophthalmic Ultrasound · PDF fileThe Basic Principles of Ophthalmic Ultrasound Devices ... Basic Structure of an Ultrasound Transducer ... The transducer sweeps

Ophthalmic UltrasoundA-Scan Example 1

Page 28: The Basic Principles of Ophthalmic Ultrasound · PDF fileThe Basic Principles of Ophthalmic Ultrasound Devices ... Basic Structure of an Ultrasound Transducer ... The transducer sweeps

Ophthalmic UltrasoundA-Scan Example 2

Page 29: The Basic Principles of Ophthalmic Ultrasound · PDF fileThe Basic Principles of Ophthalmic Ultrasound Devices ... Basic Structure of an Ultrasound Transducer ... The transducer sweeps

The transducer sweeps back and forth.

The ultrasonic beam is equivalent to a knife blade, exposing a cross section of the cut object.

B-SCAN

Page 30: The Basic Principles of Ophthalmic Ultrasound · PDF fileThe Basic Principles of Ophthalmic Ultrasound Devices ... Basic Structure of an Ultrasound Transducer ... The transducer sweeps

Ophthalmic UltrasoundB-Scan Example 1

Page 31: The Basic Principles of Ophthalmic Ultrasound · PDF fileThe Basic Principles of Ophthalmic Ultrasound Devices ... Basic Structure of an Ultrasound Transducer ... The transducer sweeps

Ophthalmic UltrasoundB-Scan Example 2

Page 32: The Basic Principles of Ophthalmic Ultrasound · PDF fileThe Basic Principles of Ophthalmic Ultrasound Devices ... Basic Structure of an Ultrasound Transducer ... The transducer sweeps

Ophthalmic UltrasoundUBM Example 1

Page 33: The Basic Principles of Ophthalmic Ultrasound · PDF fileThe Basic Principles of Ophthalmic Ultrasound Devices ... Basic Structure of an Ultrasound Transducer ... The transducer sweeps

Ophthalmic UltrasoundMore Examples

Page 34: The Basic Principles of Ophthalmic Ultrasound · PDF fileThe Basic Principles of Ophthalmic Ultrasound Devices ... Basic Structure of an Ultrasound Transducer ... The transducer sweeps

Ophthalmic UltrasoundMore Examples

Page 35: The Basic Principles of Ophthalmic Ultrasound · PDF fileThe Basic Principles of Ophthalmic Ultrasound Devices ... Basic Structure of an Ultrasound Transducer ... The transducer sweeps

Ophthalmic UltrasoundMore Examples

Page 36: The Basic Principles of Ophthalmic Ultrasound · PDF fileThe Basic Principles of Ophthalmic Ultrasound Devices ... Basic Structure of an Ultrasound Transducer ... The transducer sweeps

Ophthalmic UltrasoundMore Examples

Page 37: The Basic Principles of Ophthalmic Ultrasound · PDF fileThe Basic Principles of Ophthalmic Ultrasound Devices ... Basic Structure of an Ultrasound Transducer ... The transducer sweeps

Ophthalmic UltrasoundMore Examples

Page 38: The Basic Principles of Ophthalmic Ultrasound · PDF fileThe Basic Principles of Ophthalmic Ultrasound Devices ... Basic Structure of an Ultrasound Transducer ... The transducer sweeps

Thank You !