Welcome to our E-Seminar:

The API-TOF Advantage –Routine Mass Accuracy and High Resolution

Page 2: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 2

Agilent LC/MSD TOF

Page 3: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 3

High Resolution -Accurate Mass by LC/ESI-TOF Accurate Mass provides• empirical formula

• identification and • Confirmation

• Added Selectivity• Resolution to separate isobaric compounds• All spectra automatically calibrated for mass

peaks within 5 ppm of exact mass

Page 4: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 4

How Much Accuracy in Needed?

Reserpine (C33H40N2O9) has a protonated ion at 609.28066Single quad reports mass to +/- 0.1 = 165 ppmNumber of possible formulas using only C, H, O & N:165 ppm 20910 ppm 135 ppm 73 ppm 42 ppm 2

Accurate mass reduces risk of investing effort on the wrong molecule

Page 5: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 5

The Potential TOF Advantage

Routine Mass Accuracy < 3ppm• No user interaction required• Delivered over broad dynamic range• Immune to broad swings in laboratory environment

Resolution > 4000 at low mass, > 10,000 at higher massesFast scanning (> 5/second) over broad mass range

Page 6: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 6

Confirmation with Accurate Mass

Accurate mass determination provides a level of selectivity independent of fragments from an MS/MS experimentDetermination of empirical formulaAn accurate mass measurement does not guarantee a unique empirical formula at 5 ppm confidence levelUsually other information can be combined with TOF data to raisecertainty

Page 7: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 7

Reserpine Confirmation

Consistent isotope ratios

14 double bond equivalents (DBE)

Page 8: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 8

Agilent Design Optimizes Ion Transmission and Mass Resolving Power

Two Stage IonMirror

5 Stage Vacuum System

Agilent Orthogonal Spray Source(s)

Optically CoupledIon Detector

Beam cooling and guidance

Effective Flight PathLength of 2.0m

Low CTE InnerFlight Tube

Page 9: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 9

A Time of Flight Scan

1. Pulse ions every 100 microseconds

2. Measure at detector each nanosecond

3. 100,000 data points in each transient

4. Sum 2000 – 10000 transients into one scan

5. Produces spectra with excellent ion statistics

Pulser Detector

20 µsec – m/z 118

46 µsec - m/z 622

90 µsec - m/z 2421

Page 10: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 10

Some Key Hardware Design Features

Uses Agilent orthogonal spray sources and ion optics for superior sensitivity and flow rate rangeFlight tube designed with minimal coefficient of thermal expansionTemperature sensitive electronic components placed in temperature controlled environmentADC digitization for maximum mass accuracy over broad dynamic rangeUse CDS and dual sprayer for internal reference mass correction

Page 11: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 11

Fundamentals of TOF Mass Assignment

Agilent Goal: Routine high mass accuracyHardware designed for highly stable mass measurement Hardware and software for transparent internal reference mass correctionMathematical error in mass assignment & calibration mass accuracy within ~1 ppm for peak finder & mass assignment algorithms• Traditional algorithms can have errors > 10 ppm with discrete data.• New algorithm has intrinsic mass errors < 1 ppm with discrete data and

non-symmetric peaks

Page 12: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 12

TDC versus ADC

Time to Digital Conversion (TDC) only measures time of arrival of first ion at a given m/z valueMore sample means more ions means earlier arrivalRequires higher acquisition rate than ADC and peak intensity matching to accurately assign massReduced dynamic range

Analog to Digital Conversion (ADC) records time and number of ions arrivingSample concentration does not impact (maximum) arrival timeProvides wider dynamic range

Page 13: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 13

Understanding the TDC and ADC

1. Single ion arrives at the detector. The resulting signal crosses a preset TDC threshold and the arrival time is recorded.

2. This time the sample is more concentratedand two ions arrive slightly spaced in time asdetermined by the instrument’s resolvingpower. The yellow line is the resulting signal.

But, the TDC threshold triggers off the first ion and the arrival of the second ion is not detected. This causes as shift to shorter arrival times for higher signal levels.

3. ADC acquisition make a conversion each 0.001usec of the total signal. ADC systemsdo not drop ions or suffer from “dead time”effects.

Ion Flight Time: Is the centroid of all detected ions

Page 14: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 14

Break Number 1

For questions, at break please dial 1 on your phone, or type onto the chat screen at any time during the presentation.

Page 15: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 15

Ref. Mass Correction with m/z 118 and 922

m/z 582.319

100,000 Arb.U

nits

250 Arb.U

nits

m/z 922.0101.6 ppmerror

Ref. Mass

400x

Theoretical Abundance ErrorMass Arb. Units (ppm)

487.73253 1316 0.61450.2364 5304 1.59

722.81666 6611 0.64417.21191 6910 2.66512.25457 8978 1.66464.25036 12534 0.73519.21717 575 0.06

653.3617 21881 1.38435.91023 555 -0.28501.79513 10141 -0.04820.47251 842 0.25526.58871 3100 0.35674.32258 1881 -1.4480.60877 23885 -2.52582.31897 49027 1.57710.84248 3863 -1.16627.97323 13881 0.55474.23075 24508 1.13507.81333 11016 0.68740.40136 9671 -0.12

“Unknown”

784.37501 643 -3.49

Page 16: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 16

Automatic Internal Referencing

Reference Sprayer

Analytical Sprayer

Page 17: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 17

Mass Accuracy and Dynamic Range

XIC of +TOF MS: 609.3 amu from 10pg_res4.wiff Max. 2395.0 cps.

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0Time, min0

200

400

600

800

1000

1200

1400

1600

1800

2000

2200

2395

Intensity, cps

0.3825

10 pg Reserpine, external calibration

Mass assignment = 609.2809

Error = 0.4 ppm

Page 18: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 18

Spectral Saturation and Mass Accuracy

XIC of +TOF MS: 409.3 amu Max. 3.7e6 cps.

0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2Time, min

0.0

8.0e5

1.6e6

2.4e6

3.2e6

Intensity, cps

409.30

m/z, amu408.0 408.5 409.0 409.5 410.0 410.5 411.0 411.5 412.00%

20%

40%

60%

80%

100%409.2837

410.2648

409.2597

410.2630

Actual mass 409.2598

Page 19: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 19

Automatic Thresholding of Spectra

Evaluates spectra across peak. Uses only spectra above user specified threshold and below specified percentage of saturation

Page 20: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 20

Results with 50% Threshold

Mass Accuracy Using Threshold

-3

-2

-1

0

1

2

3

4

5

6

7

1000 10000 100000 1000000

Ion Abundance

Mas

s Er

ror,

ppm

Page 21: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 21

Mass Resolving Power

Masses from standard Agilent tune mix solution

R=4,700 R=9,300

622 623 624

R=13,500

2722 2724

Arb.Units

Arb.Units

Arb.Units

m/z m/zm/z 118 119 120

Page 22: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 22

TOF Software User Interface

32-bit client server based with modular componentsFour separate panes for instrument status, real-time display, method editing and worklist managementEach pane may be sized, displayed or hidden to meet current user needsExtensive use of right mouse click similar to other Windows applications

Page 23: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 23

Easy Optimization and Calibration

AutotuneQuicktuneChecktuneCalibrate

Page 24: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 24

CheckTune Report

Page 25: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 25

CheckTune Report – Expanded View

Page 26: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 26

Break Number 2

For questions, at break please dial 1 on your

phone, or type onto the chat screen at any time during the presentation.

Page 27: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 27

Identification of Unknowns

• Empirical formula determination can greatly assist the identification of unknowns

• The list of possibilities is smaller with mass >250• At 5 ppm accuracy the possibilities are few at low mass• The use of isotope patterns can reduce the list of possibilities even

further by specifying or eliminating atoms, determining approximate carbon content etc.

• At > 250 mass units, 3 ppm accuracy reduces the possibilities

Page 28: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 28

Identifying Trace Contaminants in Pharmaceuticals

100 – fold magnification

Page 29: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 29

Major Contaminant

Use knowledge of major product and synthesis process to reduce possible formula

Page 30: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 30

Using In-Source CID Information

+TOF MS: Experiment 2, 0.932 to 0.988 min from sulfa 284 a.wiff Agilent Max. 5.8e4 counts.

150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320m/z, amu0%

5%

10%15%

20%25%

30%35%

40%

45%50%

55%60%

65%70%

75%

80%

85%

90%95%

100%

Rel. Int. (%

)

156.0116

307.0027

285.0207

309.0000

Fragmentor 220 volts

[C6H6NO2S]+

Sulfachloropyridazine - C10H9N4O2SCl

MH+M+Na+

Page 31: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 31

Using Adduct Information

+TOF MS: 7.699 to 7.976 min from Irgonax 1010 2.wiff Agilent Max. 2.5e5 counts.

1192 1194 1196 1198 1200 1202 1204 1206 1208m/z, amu

0.0

2.0e4

4.0e4

6.0e4

8.0e4

1.0e5

1.2e5

1.4e5

1.6e5

1.8e5

2.0e5

2.2e5

2.4e5

2.5e5 1199.7727

1200.7765

1194.8173

1195.8213

1201.7807

1196.8258

1202.78331197.8268

1200.3141 1201.3150 1203.78581195.3564

C73H108O12 - MW 1176.7841- 0.5 ppm error

M+NH4+

M+Na+

Page 32: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 32

Confirmation with Accurate Mass

Accurate mass determination provides a level of selectivity independent of fragments from an MS/MS experimentDetermination of empirical formula• An accurate mass measurement is NOT exclusive of all empirical

formulas at 5 ppm confidence level• A proposed compound ID or structure IS exclusive

• That is there is only one empirical formula for a proposed compound- CONFIRMATION

Page 33: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 33

Empirical Formula Conformation Report

Input one or more formulas for each sample

Edit method to choose adducts, thresholding, report destination

System calculates target mass, extracts ions and calculates mass error

Reports can be printed or viewed from Internet Explorer

Complete Worklist results output in CSV format

Page 34: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 34

Expanded View of Results

Page 35: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 35

Quantification with ESI-TOF

The high resolution achieved (>5000 at m/z=250 and 10,000 at m/z= 1000) increases selectivity tremendously!The dynamic range is greatly enhanced with the use of analog to digital conversion (ADC)!All FULL SCAN SPECTRA are autocalibrated in the saved data file with the seamless reference mass addition

Page 36: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 36

Drugs of Abuse-LC/ESI-TOFTIC of +TOF MS: from drug screen Max. 8.2e6 cps.

1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0

Time, min

1.5e6

2.0e6

2.5e6

3.0e6

3.5e6

4.0e6

4.5e6

5.0e6

5.5e6

6.0e6

6.5e6

7.0e6

7.5e6

8.0e6

Inte

nsity

, cps

9.46

8.18

8.04 10.76

6.36

5.413.393.94

8.811.38

6.12

11.59

9.80

1.62

Page 37: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 37

Rt (min) Compound3.37 hydrocodone3.40 unknown with M+H =166.12213.64 Oxycodone3.70 Amphetamine3.81 Codeine3.94 Methamphetamine5.41 Cocaine6.12 CE6.36 PCP8.04 Propoxyphene8.18 Methadone8.81 Alprazolam9.00 Nordiazepam9.46 Methaqualone

10.86 Diazepam* Special thanks to the Lucas Zarwell of the Washington D.C. Medical Examiner’s Office for kindly providing the reference materials.

Page 38: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 38

Extracted Ion Chromatogram of m/z 300 and Spectra of Two Isomers

XIC of +TOF MS: 300.0 to 300.2 amu Max. 6.9e5 cps.

1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0Time, min0.0

1.0e5

2.0e5

3.0e5

4.0e5

5.0e5

6.0e5

6.9e5

Inte

nsity

, cps

3.81

3.37

Hydrocodone

Codeine

m/z, amu m/z, amu

+TOF MS: 3.786 to 3.844 min .

299.0 299.8 300.6 301.4 302.2

4.0e4

8.0e41.0e5

1.4e5

1.8e5

2.2e5

2.6e5

3.0e5

3.4e5 300.1595

301.1634

+TOF MS: 3.363 to 3.401 min

299.0 300.0 301.0 302.0

4.0e4

8.0e4

1.2e5

1.6e51.8e5

2.2e5

2.6e5

3.0e5

3.4e5

3.7e5

300.1595

301.1633

Page 39: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 39

Drugs of Abuse Mass Accuracy at 3 orders of Magnitude Concentration

Compound Amphetamine Methamphetamine Hydrocodone Codeine Oxycodone150.1

measurederror (ppm) error (ppm)

50 -4.71 -3.01 0.37 0.37 0.0450 -4.53 -3.03 0.47 0.37 -0.1650 4.53 -3.05 0.3 0.3 -0.7525 3.53 -2.49 1.17 1.60 0.27

*2.5 -5.57 -2.88 0.60 0.27 -0.432.5 5 -2.78 1.6 1.6 -0.420.5 -4.23 -2.2 1.34 1.90 0.040.5 -5.01 -2.48 1.11 1.27 -0.330.25 -5.7 -2.69 0.95 1.27 -1.160.05 5.00 -5.42 3.6 2.26 0.53

Nominal m/z 136.1 300.15 300.15 316.15Conc measured measured measured measured

(ng-injected) error (ppm) error (ppm) error (ppm)

Page 40: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 40

25201510 5 0

3000000

2000000

1000000

0

Conc ng/ul

Area

Codeine Linearity

Codeine Response from 50 pg to 25 ng On-column

Page 41: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Food Safety Examples

Chloramphenicol (CAP) Antibiotic banned in Foods at 0.1 ppb

Page 42: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 42

0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5Time, min

0

100

200

300

400

500

600

700

800

900

Intensity, cps

4.89

6 pg CAP on-column

.

318.5 319.5 320.5 321.5 322.5 323.5 324.5 325.5 326.5 327.5m/z, amu

0

60

120

180

240

300

360

420

480

540

600

Intensity, counts

321.0042

323.0008

Exact mass 321.00505 error at 6 pg 3.08 ppm

NH

OH

OHN+

O-

O

O

Cl

Cl

Page 43: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 43

Chloramphenicol (negative ion mode) mass accuracy in ppm

pg injected rep 1 rep 2 rep 3 mean19000 -2.48 -2.54 -3.03 2.73900 -2.35 -2.94 -2.63 2.6770 -0.84 -2.13 -1.58 1.5

154.4 -1.49 -1.66 -3.36 2.231 0.58 -0.03 -3.18 0.9

6.2 ND ND -3.08 3.1

Page 44: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 44

43210

300000

200000

100000

0

Conc(ng)

Area

Chloramphenicol Linearity

Chloramphenicol Response from 6 pg to 4 ng On-column

Page 45: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Nitrofuran Metabolites in Poultry

THE SELECTIVITY OF HIGH RESOLUTION ACCURATE MASS MEASUREMENT!!

Page 46: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 46

NPAMOZ at Unit Mass Resolution335.1352 -0.7+0.3

XIC of +TOF MS: 334.4 to 335.4 amu from Sample 18 (Blank Poultry+0.5ppb) of Nitrodfuransequence1.wiff Max. 2.0e5 cps.

0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5Time, min

0.0

5000.0

1.0e4

1.5e4

2.0e4

2.5e4

3.0e4

3.5e4

4.0e4

4.5e4

5.0e4

5.5e4

6.0e4

6.5e4

6.8e4

Inte

nsity

, cps

123.06

123.05

Page 47: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 47

NPAMOZ 335.1352 ± 0.1

XIC of +TOF MS: 335.0 to 335.2 amu from Sample 18 (Blank Poultry+0.5ppb) of Nitrodfuransequence1.wiff Max. 1.7e5 cps.

0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5Time, min

0.0

2000.0

4000.0

6000.0

8000.0

1.0e4

1.2e4

1.4e4

1.6e4

1.8e4

2.0e4

2.2e4

2.4e4

2.6e4

2.8e4

3.0e4

3.2e4

3.4e4

Inte

nsity

, cps

123.06

S/N = 70:1

Page 48: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 48

NPAMOZ 335.1352 +- 20ppm(335.1262-335.1396)

XIC of +TOF MS: 335.1 to 335.1 amu from Sample 18 (Blank Poultry+0.5ppb) of Nitrodfuransequence1.wiff Max. 1.0e4 cps.

0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0Time, min

0

100

200

300

400

500

600

700

800

900

1000

1100

1200

1300

1400

1500

1600

1700

1800

1900

2000

2100

2200

2300

2400

2500

2600

2700

2800

2900

3000

3100

3200

Inte

nsity

, cps

123.05

S/N = 214:1

Page 49: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Chromatographic and Spectral Data

ESI TOF Positive ion

20 MICROLITER INJECTION OF WATER SAMPLE 119

Page 50: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 50

TIC and BPC OF WATER SAMPLE 119

Page 51: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 51

EICs OF WATER SAMPLE 119

Page 52: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 52

EICs OF WATER SAMPLE 119

Page 53: The API-TOF Advantage – Routine Mass Accuracy and High … · 2015. 10. 6. · Dial 1-816-650-0621 for e-Seminar Audio Slide 3 High Resolution -Accurate Mass by LC/ESI-TOF Accurate

Dial 1-816-650-0621 for e-Seminar AudioSlide 53

Conclusions• Agilent LC/MSD ESI-TOF offers routinized accurate mass

measurementSeamless addition of lock-massAuto-calibration of every stored scanBetter than 5 ppm at low mass and 3 ppm at higher mass

• Confirmation and identification of unknowns• Quantitative response

up to 3 orders of magnitude linearity (within range of ESI)Greater selectivity

From higher mass resolution (>4000 for low mass and 10000 for high mass)And accurate mass automatically stored for every scan