Ammonia Vent of the External Active Thermal Control System (EATCS) Radiator #3 Flow Path #2 on the International Space Station (ISS) Darnell Cowan NASA JSC ATCS Presented By Darnell Cowan Thermal & Fluids Analysis Workshop TFAWS 2018 August 20-24, 2018 NASA Johnson Space Center Houston, TX TFAWS Active Thermal Paper Session
17

TFAWS Active Thermal Paper Session · 2019. 5. 20. · Thermal Control System (EATCS) Radiator #3 Flow Path #2 on the International Space Station (ISS) Darnell Cowan NASA JSC ATCS

Sep 15, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: TFAWS Active Thermal Paper Session · 2019. 5. 20. · Thermal Control System (EATCS) Radiator #3 Flow Path #2 on the International Space Station (ISS) Darnell Cowan NASA JSC ATCS

Ammonia Vent of the External Active

Thermal Control System (EATCS)

Radiator #3 Flow Path #2 on the

International Space Station (ISS)

Darnell Cowan

NASA JSC ATCS

Presented By

Darnell Cowan

Thermal & Fluids Analysis Workshop

TFAWS 2018

August 20-24, 2018

NASA Johnson Space Center

Houston, TX

TFAWS Active Thermal Paper Session

Page 2: TFAWS Active Thermal Paper Session · 2019. 5. 20. · Thermal Control System (EATCS) Radiator #3 Flow Path #2 on the International Space Station (ISS) Darnell Cowan NASA JSC ATCS

Overview

• Background

• EATCS Overview

• International Space Station

• Venting Analysis Problem Definition

• Modeling

• Assumptions

• Analysis Results

• On-Orbit Operations Recommendations

• Comparison to On-Orbit Operations

• Vent Video

• Summary

• Backup– Acknowledgments

TFAWS 2018 – August 20-24, 2018 2

Page 3: TFAWS Active Thermal Paper Session · 2019. 5. 20. · Thermal Control System (EATCS) Radiator #3 Flow Path #2 on the International Space Station (ISS) Darnell Cowan NASA JSC ATCS

Background

• Robotic External Leak Locator

(RELL) scans found higher

concentrations of vaporous

ammonia near the EATCS Loop

B Radiator #3 Flow Path #2

• On May 3, 2017, the EATCS

Loop B Radiator #3 Flow Path

#2 was isolated and vented

• As of the data to date, the

ammonia leak has ceased

• The purpose of this presentation

is to discuss the analysis for

venting the EATCS Loop B

Radiator #3 Flow Path #2

TFAWS 2018 – August 20-24, 2018 3

• The External Active Thermal Control System (EATCS) provides active cooling for all pressurized

modules and the main Power Distribution Electronics (PDE) on the International Space Station

(ISS) – 2 EATCS loops (Loop A and Loop B) each of which includes 3 deployable radiators

– Each deployable radiator contains 2 flow paths to provide heat rejection

• Telemetry monitoring identified a coolant (liquid ammonia) leak in EATCS Loop B

EA

TC

S L

oop B

Am

monia

Page 4: TFAWS Active Thermal Paper Session · 2019. 5. 20. · Thermal Control System (EATCS) Radiator #3 Flow Path #2 on the International Space Station (ISS) Darnell Cowan NASA JSC ATCS

Nitrogen

Tank

EATCS Overview

TFAWS 2018 – August 20-24, 2018 4

EATCS Loop B Simplified Schematic

FCV

S0-

RAD

DeployedP1-3

Heaters

PDE 1

JEM

MT HX

PDE 3 PDE 4

PDE 2

Node 2

LT HX

Node 3

LT HX

USL

MT HX

Ammonia Tank

Pump

GN2NH3

Key:

LT=Low Temperature

MT=Moderate Temperature

PDE=Power Distribution Electronics

FCV=Flow Control Valve

COL=Columbus Module

JEM=Japanese Experiment Module

USL= US Laboratory

HX= Heat Exchanger

COL

LT HX

PDE 5

Radiator #1

RAD

DeployedP1-3Radiator #2

RAD

DeployedP1-3Radiator #3

GN2NH3

Page 5: TFAWS Active Thermal Paper Session · 2019. 5. 20. · Thermal Control System (EATCS) Radiator #3 Flow Path #2 on the International Space Station (ISS) Darnell Cowan NASA JSC ATCS

International Space Station (ISS)

TFAWS 2018 – August 20-24, 2018 5

International Space Station

http://zombie.wikia.com/wiki/The_International_Space_Station_(ISS)

EATCS Loop B

Page 6: TFAWS Active Thermal Paper Session · 2019. 5. 20. · Thermal Control System (EATCS) Radiator #3 Flow Path #2 on the International Space Station (ISS) Darnell Cowan NASA JSC ATCS

Venting Analysis Problem Definition

• Ammonia venting analysis is performed to determine:

– Time to empty the flow path– Thrust imposed on the ISS

• The plan was to isolate the ammonia from the EATCS Loop B Radiator #3 Flow Path #2 from the rest of the EATCS, then vent the isolated volume to space

• Any residual ammonia left in the radiator could cause hydrostatic lockup (no compliance) resulting in potential hardware damage

• Furthermore, excessive thrust could cause the ISS to lose attitude control

• Flight controllers and engineers in the Mission Control Center (MCC) used this data to develop operational procedures and safety measures to perform the vent

TFAWS 2018 – August 20-24, 2018 6

Radiator Beam Valve Module

http://spaceflight101.com/iss/iss-us-eva-49-preview/

Page 7: TFAWS Active Thermal Paper Session · 2019. 5. 20. · Thermal Control System (EATCS) Radiator #3 Flow Path #2 on the International Space Station (ISS) Darnell Cowan NASA JSC ATCS

Modeling

• Mathematical model in Excel

• Radiator flow path was modeled as a

lumped reservoir – Used the worst case temperatures to represent

the entire Radiator Flow Path (~ 1 ft3)

• Ammonia vents through a small pipe

without friction directly to space and

choked at the exit – Radiator Flow Path is vented through a Tee

• Reservoir is initially a liquid

• The vent begins as a isothermal process

until the system reaches saturation (2-

phase)

• Once the reservoir reaches saturation, the

vent continues via isentropic expansion– No heat transfer

– Pressure decreases the temperature

decreases to maintain constant entropy

• Thrust and time to vent can be calculatedTFAWS 2018 – August 20-24, 2018 7

Vent Valve

Vent Model

Liquid Vapor

Vent Tee

Reservoir

F=Thrust

t=time

F,t

F,t

Page 8: TFAWS Active Thermal Paper Session · 2019. 5. 20. · Thermal Control System (EATCS) Radiator #3 Flow Path #2 on the International Space Station (ISS) Darnell Cowan NASA JSC ATCS

Additional Calculation for Thrust

• Liquid vents begin at a quality of 0 and throughout the vent the

void fraction increases until it eventually reaches a quality of 1,

this produces two independent venting regimes.

TFAWS 2018 – August 20-24, 2018 8

• Void Fractions < 0.5– Liquid vent is driven by

mechanical energy (pressure)

• Void Fractions > 0.5– Liquid vent is driven by

both mechanical energy (pressure) and thermal (temperature) energy

• liquid vent reaches the “dispersed flow” two phase regime and the liquid slugs are accelerated by the compressible gas bubbles

Page 9: TFAWS Active Thermal Paper Session · 2019. 5. 20. · Thermal Control System (EATCS) Radiator #3 Flow Path #2 on the International Space Station (ISS) Darnell Cowan NASA JSC ATCS

Assumptions

• Initial EATCS Loop B Radiator #3 Flow Path #2 pressure was

based on the maximum operating pressure requirement of

390 psia (2689 kPa)

• Initial EATCS Loop B Radiator #3 Flow Path #2 temperatures

for time to vent and thrust were based on the worst case

coldest and hottest operational temperatures observed on-

orbit over the past 2 years

– Coldest temperature ~ -40 Deg F (-40 Deg C) drives maximum vent

duration

– Hottest temperature ~ 55 Deg F (13 Deg C) drives maximum thrust

• Telemetry sensor error and temperature and pressure swings

due to orbital environmental changes are neglected

TFAWS 2018 – August 20-24, 2018 9

Page 10: TFAWS Active Thermal Paper Session · 2019. 5. 20. · Thermal Control System (EATCS) Radiator #3 Flow Path #2 on the International Space Station (ISS) Darnell Cowan NASA JSC ATCS

Analysis Results

TFAWS 2018 – August 20-24, 2018 10

EATCS Loop B Radiator #3 Flow Path #2 Pressure vs Time Plot

Based on initial Pressure and Temperature of 390

psia (2689 kPa) and -40 Deg F (-40 Deg C)

Page 11: TFAWS Active Thermal Paper Session · 2019. 5. 20. · Thermal Control System (EATCS) Radiator #3 Flow Path #2 on the International Space Station (ISS) Darnell Cowan NASA JSC ATCS

Analysis Results

TFAWS 2018 – August 20-24, 2018 11

EATCS Loop B Radiator #3 Flow Path #2 Thrust vs Time Plot

Based on initial Pressure and Temperature of

390 psia (2689 kPa) and 55 Deg F (13 Deg C)

Page 12: TFAWS Active Thermal Paper Session · 2019. 5. 20. · Thermal Control System (EATCS) Radiator #3 Flow Path #2 on the International Space Station (ISS) Darnell Cowan NASA JSC ATCS

On-Orbit Operation Recommendations

• Summary– Worst case time to empty the EATCS Loop B Radiator #3 Flow

Path #2 was ~ 60 minutes

– The predicted maximum thrusts were ~ 11 lbf (49 N) at the start

of the vent and ~10 lbf (45 N) after the system reaches

saturation

• Recommendation– For vent times,

• ATCS recommended leaving the EATCS Loop B Radiator #3 Flow

Path #2 in the vent position for no less than 24 hours to ensure all

the ammonia is evacuated

– For thrust,

• Recommend using Russian Thrusters to maintain ISS Attitude

Control

TFAWS 2018 – August 20-24, 2018 12

Page 13: TFAWS Active Thermal Paper Session · 2019. 5. 20. · Thermal Control System (EATCS) Radiator #3 Flow Path #2 on the International Space Station (ISS) Darnell Cowan NASA JSC ATCS

Comparison to On-Orbit Operations

TFAWS 2018 – August 20-24, 2018 13

Figure 9: Predicted vs Actual EATCS Loop B Radiator #3 Flow Path #2 Pressures

Predicted results bounded the actual

results

Predicted using data at the time of the vent

Initial Pressure = 316 psia (2179 kPa)

Initial Temperature= 48 Deg F (9 Deg C)

Page 14: TFAWS Active Thermal Paper Session · 2019. 5. 20. · Thermal Control System (EATCS) Radiator #3 Flow Path #2 on the International Space Station (ISS) Darnell Cowan NASA JSC ATCS

Vent Video

TFAWS 2018 – August 20-24, 2018 14

• EATCS Loop B Radiator #3 Flow Path # 2 Vent Video

available via YouTube

– https://youtu.be/PJzjs4EI22k?list=PL4Bmr2TXQTcQnxXpZ7BkG

k_t0IhTByrDy

Page 15: TFAWS Active Thermal Paper Session · 2019. 5. 20. · Thermal Control System (EATCS) Radiator #3 Flow Path #2 on the International Space Station (ISS) Darnell Cowan NASA JSC ATCS

Summary

• Predictive analysis determined the worst case time to empty the EATCS Loop B

Radiator #3 Flow Path #2 was ~ 60 minutes

• Telemetry indicated that the system reached saturation almost instantaneously

and took ~ 20 minutes to empty the EATCS Loop B Radiator #3 Flow Path #2

• Using telemetry from the day of the vent, analysis determined the time to empty

the EATCS Loop B Radiator #3 Flow Path #2 would be ~13 minutes

• The original predictive analysis used worst case inputs and assumptions which

bounded the actual results

• The maximum thrust initial time of the vent and during 2-phase were ~ 11 lbf (49

N) and ~10 lbf (45 N)

• Telemetry is not available to correlate actual thrust with the predicted maximum

thrusts

• However, by using Russian Thrusters for ISS attitude control, attitude control

telemetry indicated the flight attitude was maintained

TFAWS 2018 – August 20-24, 2018 15

Page 16: TFAWS Active Thermal Paper Session · 2019. 5. 20. · Thermal Control System (EATCS) Radiator #3 Flow Path #2 on the International Space Station (ISS) Darnell Cowan NASA JSC ATCS

Backup

TFAWS 2018 – August 20-24, 2018 16

Page 17: TFAWS Active Thermal Paper Session · 2019. 5. 20. · Thermal Control System (EATCS) Radiator #3 Flow Path #2 on the International Space Station (ISS) Darnell Cowan NASA JSC ATCS

Acknowledgments

• Would like to acknowledge the outstanding work of the

Flight Operations Directorate (FOD) and Mission

Evaluation Room (MER) engineering teams

– Particularly the following:

• The Boeing Company - Houston Active Thermal Control (ATCS)

and Passive Thermal Control Systems (PTCS) team

• FOD - Station Power, Articulation, Thermal, and Analysis

(SPARTAN) group

• NASA – Johnson Space Center (JSC) Active Thermal Control

System (ATCS) team

TFAWS 2018 – August 20-24, 2018 17