TeSys GS Fuse disconnect switches • Total isolation between poles • Safe replacement of the fuses (double breaking system) • Frontal and right side operation • Common auxiliary contacts and accessories • New design external handle TeSys DF Fuse holders • For NFC and Class CC fuses size 8x32, 10x38, 14x51 and 22x58 • Up to 690V, from 0.5 to 125Amps multi-pole configurations: 1P, N, 1P+N, 2P, 3P, 3P+N • “Blown fuse” indicator • Microswitches providing early break, fuse presence and blown fuse signaling functions Simple and effective protection TeSys GS & DF Fuse protection
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
TeSys GSFuse disconnect switches•Total isolation between poles
•Safe replacement of the fuses
(double breaking system)
•Frontal and right side operation
•Common auxiliary contacts and
accessories
•New design external handle
TeSys DFFuse holders•For NFC and Class CC fuses
size 8x32, 10x38, 14x51 and 22x58
•Up to 690V, from 0.5 to 125Amps
multi-pole configurations:
1P, N, 1P+N, 2P, 3P, 3P+N
•“Blown fuse” indicator
•Microswitches providing early
break, fuse presence and blown fuse
signaling functions
Simple and effective protection
TeSys GS & DFFuse protection
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
24112-EN.inddversion: 2.02
Presentation Protection componentsSwitch-disconnector-fuses32 to 1250 A, TeSys GS
PresentationTeSys GS switch-disconnector-fuses provide on-load breaking or making, safe
isolation and overcurrent protection of all low voltage electrical circuits.
They are used, in particular, on the incoming supply to control panels, for protecting
and switching off main circuits (including Emergency stop).
Their compact design means that they can also be fi tted in small automation system
equipment to provide the same disconnect and protection functions on the incoming
supply of equipment, generators or motor starters.
Conforming to standard IEC 60947-3, TeSys GS switch-disconnector-fuses are
available for use with:
NFC or DIN fuses,
BS fuses.
A range for use with UL fuses, specifi cally for the North-American market and
meeting the requirements of standards UL98 and CSA 22.2 Nr.4, is also available.
The TeSys GS range includes sturdy and compact handles. These handles are
easy to install and operate and are available in the following options:
Direct operator.
External front and RH side-mounted operator.
External LH side-mounted operator.
Padlockable with up to 3 padlocks. The door is locked when the handle is
padlocked.
Locking by means of a key-operated lock (option).
With door interlock in the “closed” position. When in the “Closed” position, the door
can be opened by means of a tool to be used only by authorised personnel.
Locking is automatically re-established when the door is closed.
Black/Grey or Yellow/Red for the Emergency stop function.
IP 65 or IP 55.
This range is completed by auxiliary contacts:
Two auxiliary early break and “O” and “I” position signalling contacts, confi gurable
and common to all ratings.
Auxiliary contacts GS1 AN, which are suitable for isolation.
Reversibility of these contacts to convert an N/C contact into an N/O contact and vice
versa.
Control circuit test facility, off-load, with auxiliary contacts GS1 AM110,
GS1 AM101 or GS1 ANT, used in conjunction with handles GS2 AHT.
Auxiliary “blown fuse” signalling contacts.
bb
bbbb
bb
bb
b
b
b
b
FunctionsBreaking
Quick break and quick tripping mechanism, independent of the fuses.
C Opening and closing independent of operator speed.
C On-load making and breaking of resistive, inductive or mixed resistive and
inductive circuits.
C Quality and durability of mechanical and electrical lives.
Utilisation categories AC-23/690 V and DC-23/440 V.
C Durable performance in severe duty applications.
C Direct control of motors.
b
b
Characteristics:pages 24113/2 to 24113/7
References:pages 24114/2 to 24114/7
Dimensions:pages 24115/2 to 24115/6
Schemes:page 24115/7
GS2 S3+ handle GS2 AH550
GS2 N3 + handle GS2 AH540
GS1 DD3
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
24112-EN.indd version: 2.0 3
Presentation (continued) Protection componentsSwitch-disconnector-fuses32 to 1250 A, TeSys GS
Functions (continued)
Isolation
Upstream and downstream breaking of fuses for all ratings
C Double break isolation of the power circuit and safe replacement of fuses.
C Total isolation of power and control circuits to ensure safety of persons and
equipment.
GS1 AN auxiliary contacts.
C Control circuit isolation.
Contacts forced open in the event of welding.
C Fully visible break. “Open” position cannot be indicated unless all contacts are
actually open.
C Safe opening and clear indication of “Open” state of switch-disconnector.
Visible isolation distance between the open contacts.
C Visible break (630 to 1250 A ratings).
b
b
b
b
Protection
Addition of gG (gl) fuses.
C Overload and short-circuit protection of distribution circuits and power switching
circuits without signifi cant current peak.
Addition of aM fuses (associated with thermal overload relays).
C Type 2 coordination (Iq > 50 kA) for motor starters consisting of fuses, contactors,
relays.
C Short-circuit protection of motors and equipment.
Addition of quick-blow fuses.
C Protection of electronic variable speed controllers and soft starters.
“Blown fuse” detection device.
C Protection against single-phasing.
Conditional short-circuit withstand voltage of 100 kA for all ratings.
C Equivalence between the breaking capacity of the fuses and the ability of the
switch-disconnector-fuse to withstand this maximum capacity.
C Use in installations where very high short-circuit currents can develop.
Handles with padlocking facility, with door interlock.
Handle locking by means of a key-operated lock (option).
Door interlock in “Closed” position.
Operator shafts padlockable with door open.
Fuse covers fi tted as standard on all ratings.
C Protection against accidental contact.
C Protection of persons.
IP 20 protection with terminal shrouds
bb
b
b
b
b
bbbbb
b
Information and testing
Up to 12 auxiliary contacts.
C Early break, “Open” and “Closed” position signalling, and “blown fuse” signalling.
C Use in automation systems.
Control circuit test facility, off-load, by using auxiliary contacts GS1 AM110,
GS1 AM101 or GS1 ANT in conjunction with handles GS2 AHT.
In the “Test” position, the enclosure door can be opened.
b
b
Characteristics:pages 24113/2 to 24113/7
References:pages 24114/2 to 24114/7
Dimensions:pages 24115/2 to 24115/6
Schemes:page 24115/7
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
0229Q-EN.indd version: 1.2
Applications TeSys GS switch-disconnector-fuses provide on-load breaking and making, safe isolation and They are used, in particular, on the incoming supply to control panels, for protecting and switching They provide simultaneous disconnection, together with all the other associated functions such asTheir compact design means that they can also be fi tted in small automation system equipment to
Fuse type NF C or DIN
Rated thermal current (Ith) 32 A 50 A 63 A 100 A 125 A 160 A 250 A 400 A 630 A 1250 A
Number of poles 3 or3 + Nc
3 or 4
Fuse size 10 x 38 14 x 51 T00C 22 x 58 22 x 58T00
T0T00
T1 T2 T3 T4
External operator, padlockable and lockable Front and RH sideLH side
Direct operator, padlockable Front RH side Front
Rated operational voltage (Ue) 690 V
Rated operational current (Ie) at 400 V, AC-23 A 32 A 50 A 63 A 100 A 125 A 160 A 250 A 400 A 630 A 1000 A
Rated making capacity at 400 V, AC-23B 320 A 500 A 630 A 1000 A 1250 A 1600 A 2500 A 4000 A 6300 A 10 000 A
Rated breaking capacity at 400 V, AC-23B 256 A 400 A 500 A 800 A 1000 A 1280 A 2000 A 3200 A 5040 A 8000 A
Rated conditional short-circuit current at 400 V, with gG (gI) fuses
100 kA 100 kA 100 kA 100 kA 100 kA 100 kA 100 kA 50 kA 100 kA 100 kA
Switch-disconnector-fuse type references GS1DD
GSpF
GSpG
GSpJ
GSpKor KK
GSpLor LL
GSpN
GSpQQ
GS2S
GS2V
Pages 24114/2 and 24114/3
Protection componentsTeSys GS switch-disconnector-fuses,32 to 1250 A
Selection guide
4
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
0229Q-EN.indd version: 1.2
overcurrent protection.off main circuits (including Emergency stop).padlocking and interlocking.provide the same disconnect and protection functions on the incoming supply of equipment, generators or starters, including motors.
BS
32 A 32 A 63 A 100 A 160 A 200 A 250 A 315 A 400 A 630 A 800 A 1250 A
3 or3 + Nc
3 or 4
A1 A1 A2-A3 A4Ø y 31 mm
A4B1-B2
B1-B2 B1…B3 B1…B3 B1…B4 C1-C2 C1…C3 D1
Front and RH side
Front – Front
690 V
32 A 32 A 63 A 100 A 160 A 200 A 250 A 315 A 400 A 630 A 800 A 1000 A
320 A 320 A 630 A 1000 A 1600 A 2000 A 2500 A 3150 A 4000 A 6300 A 8000 A 10 000 A
256 A 256 A 500 A 800 A 1280 A 1600 A 2000 A 2520 A 3200 A 5040 A 6400 A 8000 A
80 kA 80 kA 80 kA 80 kA 80 kA 80 kA 80 kA 80 kA 80 kA 80 kA 80 kA 80 kA
(1) Category “A”: frequent operating cycles, category “B”: infrequent operating cycles(2) 2 poles in series per phase.(3) With terminal covers.(4) Poles not juxtaposed.
Characteristics Protection componentsTeSys GS switch-disconnector-fuses, 32 to 1250 A, for use with NF C or DIN fuses
Presentation:pages 24112/2 and 24112/3
References:pages 24114/2 to 24114/7
Dimensions:pages 24115/2 to 24115/6
Schemes:page 24115/7
6
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
24113-EN.indd version: 1.2
GSp K GSp KK GSp LL GSp L GSp N GSp QQ GS2 S GS2 V
(1) Category “A”: frequent operating cycles, category “B”: infrequent operating cycles(2) 2 poles in series per phase.(3) Fit switch-disconnector-fuses GS2 LB with B1 or B2 fuses and GS2 LLB with A4 fuses.(4) With terminal covers.(5) Poles not juxtaposed.
Characteristics Protection componentsTeSys GS switch-disconnector-fuses,32 to 1250 A, for use with BS fuses
Presentation:pages 24112/2 and 24112/3
References:pages 24114/2 to 24114/7
Dimensions:pages 24115/2 to 24115/6
Schemes:page 24115/7
8
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
24113-EN.indd version: 1.2
GS2 LB or LLB (3) GS2 MMB GS2 NB GS2 PPB GS2 QQB GS2 SB GS2 TB GS2 VB
Auxiliary early break and O and I position signalling contactsSwitch rating Contact type Type of operator Reference Weight
A kg
32 1 C/O – GS1 AM111 0.080
2 C/O – GS1 AM211 0.080
50…400 1 C/O Direct, RH side GS1 AM1 0.023
2 C/O Direct, RH side GS1 AM2 0.035
Auxiliary “blown fuse” signalling contacts for use with NF C and DIN fuses (6)
Contact type Switch rating Fuse size Number of poles Reference Weight
A kg
1st C/O 50 14 x 51 3 or 4 GS1 AF1 0.025
100 and 125 22 x 58 3 GS1 AF23 0.033
4 GS1 AF24 0.037
160 Size 0 3 GS1 AF33 0.036
4 GS1 AF34 0.030
250 and 400 Size 1 and Size 2 3 GS1 AF43 0.038
4 GS1 AF44 0.032
630 Size 3 3 GS2 AF63 0.046
4 GS2 AF64 0.100
1250 Size 4 3 GS2 AF73 0.080
4 GS2 AF74 0.045
2nd C/O 50…1250 – 3 or 4 GS1 AF 0.015
(1) For 32 A switch-disconnector-fuses, these auxiliary contacts allow:- early break and O and I position signalling, - O and I position signalling,- O, I and Test position signalling, - Test position signalling.For 50 to 400 A switch-disconnector-fuses, they allow:- early break, - O and I position signalling,- O, I and Test position signalling, - Test position signalling.For 630 and 1250 A switch-disconnector-fuses, they allow:- early break and O and I position signalling,
(2) Maximum number of auxiliary contacts:
Switch rating A
Standard With additional bracket
Reference of additional bracket
32 4 4 + 4 GS1 AD10
50…160 4 4 + 4 GS2 AD20
200…400 8 8 + 4 GS2 AD20
630…1250 8 8 –
(3) The Test position allows testing of the control circuits off-load. Auxiliary contacts GS1 AM110, GS1 AM101 and GS1 ANTpponly allow the text function with external handles GS2 AHTppp.(4) These auxiliary contacts can also be used with 630, 800 and 1250 A switch-disconnector-fuses fi tted with a direct front-mounted operator.(5) Reversible add-on attachments for converting an N/C contact to an N/O contact and vice versa.(6) For striker fuses (BS fuses are not available with striker).
GS1 AM1pp
568473
GS1 AM1pp
568473
GS1 AMp11
568474
GS1 AMp11
568474
GS1 ANppp
568476
GS1 ANppp
568476
GS1 AMp
568475
GS1 AMp
568475
General :pages 24112/2 and 24112/3
Characteristics :pages 24113/2 to 24113/5
Dimensions :pages 24115/2 to 24115/6
Schemes :page 24115/7
References Protection componentsTeSys GS switch-disconnector-fuses, 32 to 1250 AAuxiliary contacts
19
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
24114-EN.indd version: 3.0
Handles for external operatorSwitch rating Handle colour Degree of protection Reference Weight
A kg
Handles for front-mounted external operators, padlockable and lockable in position O (1)
Door interlock in I position (2)
32…63 Black/Grey IP 65 GS2 AH510 0.200
IP 55 GS2 AH515 0.200
Red/Yellow IP 65 GS2 AH520 0.200
100…400 Black/Grey IP 65 GS2 AH530 0.240
IP 55 GS2 AH535 0.240
Red/Yellow IP 65 GS2 AH540 0.240
630 and 800 Black/Grey IP 65 GS2 AH550 0.280
Red/Yellow IP 65 GS2 AH560 0.280
1250 Black/Grey IP 65 GS2 AH570 0.390
Red/Yellow IP 65 GS2 AH580 0.390
Handles for front-mounted external operators with test facility (3), padlockable and lockable in "O"
position (1). Door interlock in “I” position (2)
32…63 Black/Grey IP 65 GS2 AHT510 0.200
Red/Yellow IP 65 GS2 AHT520 0.200
100…400 Black/Grey IP 65 GS2 AHT530 0.240
Red/Yellow IP 65 GS2 AHT540 0.240
Handles for external RH side-mounted operators, padockable and lockable in "O" position (1)
32…63 Black/Grey IP 65 GS2 AH210 0.200
IP 55 GS2 AH215 0.200
Red/Yellow IP 65 GS2 AH220 0.200
100…400 Black/Grey IP 65 GS2 AH230 0.240
IP 55 GS2 AH235 0.240
Red/Yellow IP 65 GS2 AH240 0.240
630…1250 Black/Grey IP 65 GS2 AH250 0.280
Red/Yellow IP 65 GS2 AH260 0.280
Handles for external LH side-mounted operators, padockable and lockable in "O" position (1)
(1) Lockable with device GS2 AX1, to be ordered separately.(2) Door interlock override by means of a tool.(3) The Test facility allows testing of the control circuits off-load, by using auxiliary contacts GS1 AM110, GS1 AM101 or GS1 ANTpp. In the “Test” position, the enclosure door can be opened.
References Protection componentsTeSys GS switch-disconnector-fuses, 32 to 1250 AHandles for external operators
538653
GS2 AHp70GS2 AHp80
538654
GS2 AHp50GS2 AHp60
538655
GS2 AHp30GS2 AHp40
538656
GS2 AHp10GS2 AHp20
20
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
24114-EN.indd version: 3.0
Handles for external operatorsSwitch rating Type of operator Handle colour Reference Weight
A kg
Handles for direct operators, padlockable
32 Front Black GS1 AH103 0.060
50 and 63 RH side Black GS1 AH01 0.060
100…400 RH side Black GS1 AH02 0.100
630 and 800 Front Black GS2 AH104 0.480
1250 Front Black GS2 AH105 0.600
Terminal protection shrouds for upstream or downstream connector platesSwitch rating Number of poles Reference Weight
A kg
50 and 63 3 or 4 (1) –
100…160 3 GS1 AP33 0.073
4 GS1 AP34 0.180
200…400 3 GS1 AP43 0.240
4 GS1 AP44 0.280
630…800 3 GS2 AP63 0.520
4 GS2 AP64 0.780
1250 3 GS2 AP83 0.680
4 GS2 AP84 0.840
Devices for locking fuse covers in "I" position (2)
Switch rating Fuse size Number of poles Reference Weight
A kg
50 14 x 51 3 or 4 (3) –
63 Size 00C 3 or 4 GS1 AV1 0.012
100…160 22 x 58, Size 00 3 or 4 GS1 AV2 0.040
160 Size 0 3 GS1 AV33 0.026
4 GS1 AV34 0.010
250 Size 1 3 GS1 AV53 0.026
4 GS1 AV54 0.010
400 Size 2 3 GS1 AV73 0.027
4 GS1 AV74 0.033
Cage terminals for connection of bare cables (without lug)Switch rating Number of poles Reference Weight
50…400 The kit, for use with a front-mounted external handle,includes:
a 200 mm shaft, cross section 10 x 10 mm,an adapter plate
bb
GS2 ADL2 0.300
(1) For these ratings, the switch-disconnector-fuses are fi tted with terminal covers as standard.(2) For NF C and DIN switch-disconnector-fuses fi tted with right-hand mounted direct operator.(3) For this rating, switch-disconnector-fuses are fi tted with a cover locking device as standard.(4) For these ratings, switch-disconnector-fuses are fi tted with cage terminals as standard.
GS1 AH01
568668
GS1 AH01
568668
GS1 AH02
568669
GS1 AH02
568669
References Protection componentsTeSys GS switch-disconnector-fuses, 32 to 1250 AHandles for external operators Accessories
21
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
24115-EN.indd version: 1.1
GS1 DD (32 A)Direct front-mounted operator
GS1 DD GS1 DDB
45
65 8,514
96
37,5
35
15
21,5 17
21,5
5,2
112
44
19 6,579,5
98
2xØ5
98
45
65 8,5
14
96
37,5 15
5,2
112
44
19 6,5
79,5
8398
2xØ5
External front-mounted operator
GS1 DD Door cut-out
1537,5
14
44
70
90°65°
I
Test
O
35
49
Ø78
102 min. (1)
4xØ7
28
40
Ø37
GS1 DDB Door cut-out
14
35
90°65°
I
Test
O
Ø78
44
70
37,5 15
49
102 min. (1)
(1) With 1 or 2 auxiliary contacts GS1 AM1pp: 130 mm.(2) With 3 or 4 auxiliary contacts GS1 AM1pp: 155 mm.
4xØ7
28
40
Ø37
External RH side-mounted operator
GS1 DD Door cut-out
49
49
441970 6,5 96
52,5
I
70
90°
O
Ø7836 min.
40
4xØ7
28
Ø37
GS1 DDB Door cut-out
4496
52,5
49
49
I
70
90°
O
Ø781970 6,5 36 min.
40
4xØ7
28
Ø37
Dimensions Protection componentsTeSys GS switch-disconnector-fuses,32 to 1250 A
Presentation:pages 24112/2 and 24112/3
Characteristics:pages 24113/2 to 24113/5
References:pages 24114/2 to 24114/7
Schemes:page 24115/7
22
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
24115-EN.indd version: 1.1
GS1 pp (50…400 A)Direct RH side-mounted operator
GS1 FD (50 A), GD (63 A), JD (100 A), KD, KKD (125 A), LD, LLD (160 A), ND (250 A) and QQD (400 A)
R
G1
Ø
M70°
P P P1
b
b2
b1
a1
a
K(2)
J G
R1
31
c
L
c1
c2
(1)
(4)(5)
Q
H
(3)
I
O
GS1 a a1 b b1 b2 c c1 c2 G G1 H J K Ø L M P P1 Q R R1 Ø
(1) Terminal cover.(2) Mounting on 5 rail only for GS1 FD and GS1 GD (50 and 63 A).(3) Protective screen, lockable in I position.(4) 1 or 2 auxiliary contacts GS1 AFpp.(5) 1 or 2 auxiliary contacts GS1 AMp.
Dimensions (continued) Protection componentsTeSys GS switch-disconnector-fuses,32 to 1250 A
Presentation:pages 24112/2 and 24112/3
Characteristics:pages 24113/2 to 24113/5
References:pages 24114/2 to 24114/7
Schemes:page 24115/7
23
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
24115-EN.indd version: 1.1
GS2 pp (50…400 A)External front and RH side-mounted operator
GS2 DB (32 A), F (50 A), G, GB, JB (63 A), J (100 A), K, KK (125 A), L, LL, LB, LLB (160 A), MMB (200 A), N, NB (250 A), PPB (315 A), QQ and QQB (400 A)
P
P2
P3
c1
M1
M2
P
J
G1
G J1 J2
45
Ø
45
(1)
(2)
(3)
(4)
a
31
c
b2
H
b2
Mb
b3
b1
P2
P1
P2
Q
Ø
E min.
20 min.230 max.
GS2 a b b1 b2 b3 c c1 E min. G G1 H J J1 J2 Ø M M1 M2 P P1 P2 P3 Q Ø