4. 4.1 RETs with RSU40 (UMTS2100) Configuration file: Upload to FTP server Z:\Common\Testing\TMA test\TestReport\ConfigFile NB version : Figure 4.1.1: NB SW version 4.1.1 Device Management 4.1.1.1 Cascaded RETs Devices Scan Figure 4.1.1.1.1 shows AISG Device Scan in left nevigation tree , right click to scan AISG device.
20
Embed
TestReport_4.1 RETs With RSU40 (UMTS2100) (Cascaded)
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
4.
4.1 RETs with RSU40 (UMTS2100)
Configuration file:
Upload to FTP server Z:\Common\Testing\TMA test\TestReport\ConfigFile
NB version :
Figure 4.1.1: NB SW version
4.1.1 Device Management
4.1.1.1 Cascaded RETs Devices Scan
Figure 4.1.1.1.1 shows AISG Device Scan in left nevigation tree , right click to scan AISG device.
Figure 4.1.1.1.1: Right click to scan AISG device
Figure 4.1.1.1.2 shows the protocol choose AISG 2.0, and Rack No is 4, Rack 4 is the RSU40 rack that
the RET connected.
Figure 4.1.1.1.2: Choose the rack to scan
It will take a while to scan , figure 4.1.1.1.3 shows 3 RETs are scanned.
Figure 4.1.1.1.3: Scan result
4.1.1.2 Add Cascaded RETs AISG Device
In left nevigation tree ,choose AISG device. Right click to choose "Linkage Scan Records Configure".
Figure 4.1.1.2.1: Right click to add AISG device
Figure 4.1.1.2.2 shows RET which serial number is KACSD4533585(shown on the lable of the antenna)
is connected to RSU40-U216(4,1,1)-Ret-1.The same way to add the other RET devices to rack 2 and
rack 7 respectively, as shown in figure 4.1.1.2.3 and figure 4.1.1.2.4.
Figure 4.1.1.2.2: Add RET to rack 4
Figure 4.1.1.2.3: Add RET to rack 2
Figure 4.1.1.2.4: Add RET to rack 7
Figure 4.1.1.2.5 shows 3 RETs are added .
Figure 4.1.1.2.5: RETs are added
4.1.1.3 Delete Cascaded RETs AISG Devices
Figure 4.1.1.3.1 shows right click to delete the AISG device.
Figure 4.1.1.3.1: Delete AISG device
4.1.2 Application Layer Test
4.1.2.1 Alarm Management
Unplug AISG cable between the second cascaded RET and the third cascaded RET, “RET
communication is interrupted”are reported. The alarms show in EOMS rack status illustration as figure
4.1.2.1.1 shows.
Figure 4.1.2.1.1: Real-time alarm in rack status illustration
4.1.3 Configuration Management
4.1.3.1 Reset AISG Devices– OMCB
Figure 4.1.3.1.1 shows choose one RET and right click to reset.