testo 720 Technical data / Accessories testo 720 testo 720, 1 channel temperature measuring instrument Pt100/NTC, with battery and calibration protocol Part no. 0560 7207 General technical data Oper. temp. -20 to +50 °C Storage temp. -30 to +70 °C Battery type 9V block battery Battery life 70 h Dimensions 182 x 64 x 40 mm Weight 171 g Material/Housing ABS Warranty 2 years Accessories Part no. Accessories for measuring instrument 0515 0025 9V rech. battery for instrument, instead of battery 0554 0025 0554 0549 0554 0568 0516 0221 0516 0210 0516 0201 0516 0200 0554 0004 0520 0001 0520 0021 0520 0031 0520 0211 0520 0071 0520 0271 Recharger for 9V rechargeable battery for external recharging of 0515 0025 battery Testo fast printer with wireless infrared interface, 1 roll thermal paper and 4 AA batteries Spare thermal paper for printer (6 rolls), permanent ink TopSafe, protects from impact and dirt (incl. 2 attachment magnets) Case for measuring instrument and probes Transport case for meas. instr. and probes (405 x 170 x 85 mm) Transport case for measuring instrument, 3 probes and accessories (430 x 310 x 85 mm) Silicone heat paste (14g), Tmax = +260°C improves heat transfer in surface probes ISO calibration certificate/temperature for air/immersion probes, calibration points -18°C; 0°C; +60°C ISO calibration certificate/temperature Meas. instr. with air/immersion probe; cal. points 0°C; +150°C; +300°C ISO calibration certificate/temperature meas. instr. with air/immersion probe; calibration points 0°C; +300°C; +600°C DAkkS calibration certificate/temperature meas. instr. with air/immersion probe; calibration points -20 °C; 0 °C; +60 °C ISO calibration certificate/temperature meas. instr. with surface probe; calibration points +60°C; +120°C; +180°C DAkkS calibration certificate/temperature contact surface temperature probes; calibration points +100°C; +200°C; +300°C Sensor types Pt100 NTC Meas. range -100 to +800 °C -50 to +150 °C Accuracy ±1 digit ±0.2% of mv (+200 to +800 °C) ±0.2 °C (remaining range) ±0.2 °C (-25 to +40 °C) ±0.3 °C (+40.1 to +80 °C) ±0.4 °C (+80.1 to +125 °C) ±0.5 °C (remaining range) Resolution 0.1 °C 0.1 °C We measure it.
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
testo 720
Technical data / Accessories
testo 720
testo 720, 1 channel temperature measuringinstrument Pt100/NTC, with battery andcalibration protocol
Part no. 0560 7207
General technical data
Oper. temp. -20 to +50 °C
Storage temp. -30 to +70 °C
Battery type 9V block battery
Battery life 70 h
Dimensions 182 x 64 x 40 mm
Weight 171 g
Material/Housing ABS
Warranty 2 years
Accessories Part no.
Accessories for measuring instrument
0515 00259V rech. battery for instrument, instead of battery
0554 0025
0554 0549
0554 0568
0516 0221
0516 0210
0516 0201
0516 0200
0554 0004
0520 0001
0520 0021
0520 0031
0520 0211
0520 0071
0520 0271
Recharger for 9V rechargeable battery for external recharging of 0515 0025 battery
Testo fast printer with wireless infrared interface, 1 roll thermal paper and 4 AA batteries
Spare thermal paper for printer (6 rolls), permanent ink
TopSafe, protects from impact and dirt (incl. 2 attachment magnets)
Case for measuring instrument and probes
Transport case for meas. instr. and probes (405 x 170 x 85 mm)
Transport case for measuring instrument, 3 probes and accessories (430 x 310 x 85 mm)
Silicone heat paste (14g), Tmax = +260°Cimproves heat transfer in surface probes
ISO calibration certificate/temperaturefor air/immersion probes, calibration points -18°C; 0°C; +60°C
ISO calibration certificate/temperatureMeas. instr. with air/immersion probe; cal. points 0°C; +150°C; +300°C
ISO calibration certificate/temperature meas. instr. with air/immersion probe; calibration points 0°C; +300°C; +600°C
DAkkS calibration certificate/temperaturemeas. instr. with air/immersion probe; calibration points -20 °C; 0 °C; +60 °C
ISO calibration certificate/temperaturemeas. instr. with surface probe; calibration points +60°C; +120°C; +180°C
Class A (-50 to +300 °C), ClassB (remaining range) 1)
±0.2 °C (-25 to +80 °C)±0.4 °C (remaining range)
±0.5% of mv (+100 to +150 °C)±0.2 °C (-25 to +74.9 °C)±0.4 °C (remaining range)
±0.5% of mv (+100 to +150 °C)±0.2 °C (-25 to +74.9 °C)±0.4 °C (remaining range)
Class A (-50 to +300 °C), ClassB (remaining range) 1)
±0.2 °C (-25 to +70 °C)±0.4 °C (-50 to -25.1 °C)
Class A (-50 to +300 °C), ClassB (remaining range) 1)
Class B 1)
t99
45 s12 s1)
60 s
35 s
10 s
70 s
60 s
12 s
40 s
Part no.
0609 7072
0613 1712
0613 1912
0613 1212
0609 1773
0613 4611
0609 1273
0609 1973
Laboratory probes
Air probes
200 mm
115 mm
115 mm
115 mm
114 mm
300 mm
114 mm
114 mm
30 mm
50 mm
50 mm
50 mm
50 mm
50 mm
Ø 6 mm
Ø 5 mm
Ø 5 mm
Ø 5 mm
Ø 5 mm
Ø 5 mm
Ø 5 mm
Ø 5 mm
Ø 4 mm
Ø 6 mm
Ø 4 mm
Ø 4 mm
Ø 3.7 mm
Ø 9 mm
Surface probes
Immers./penetr. probes
The measuring instrument inside TopSafe is waterproof with this probe. 1) According to standard 60751, the accuracies of Class A and B refer to -200 to +600 °C (Pt100)
We measure it.
testo 720
www.testo.co.uk 0981
933
4/msp
/A/01.20
12Sub
ject to ch
ange
with
out no
tice.
Probes
Probe type
Stainless steel NTC food probe(IP65) with PUR cable, Fixed cable
Stainless steel NTC food probe(IP67) with PTFE cable to +250°C,Fixed cable
Robust NTC food penetrationprobe with special handle,reinforced PUR cable, Fixed cable
±0.5% of mv (+100 to +150 °C)±0.2 °C (-25 to +74.9 °C)±0.4 °C (remaining range)
±0.5% of mv (+100 to +150 °C)±0.2 °C (-25 to +74.9 °C)±0.4 °C (remaining range)
±0.5% of mv (+100 to +150 °C)±0.2 °C (-25 to +74.9 °C)±0.4 °C (remaining range)
±0.5% of mv (+100 to +140 °C)±0.2 °C (-25 to +74.9 °C)±0.4 °C (remaining range)
Class A (-50 to +300 °C), ClassB (remaining range) 1)
t99
8 s
8 s
7 s
20 s
10 s
Part no.
0613 2211
0613 3311
0613 2411
0613 3211
0609 2272
Food probes
125 mm
125 mm
115 mm
110 mm
125 mm
15 mm
15 mm
30 mm
30 mm
15 mm
Ø 4 mm
Ø 4 mm
Ø 5 mm
Ø 8 mm
Ø 4 mm
Ø 3 mm
Ø 3 mm
Ø 3.5 mm
Ø 4 mm
Ø 3 mm
The measuring instrument inside TopSafe is waterproof with this probe. 1) According to standard 60751, the accuracies of Class A and B refer to -200 to +600 °C (Pt100)2) Long-term measurement range +125°C, short-term +150°C or +140°C (2 minutes)