Page 1
TESTING NVLAP LAB CODE 600150-0
Laboratory: Dongguan New Testing Centre Co., Ltd Address: 3F, No. 1 the 1st North Industry Road, Songshan Lake Science & Technology Park, Dongguan,
Guangdong, China
Tel: 86-769-22212079
Website: http://www.ntc-cert.com
Report No: NTCLR20120116
Report Version: V1.4
Page 1 of 15
Photometric Test Report
Relevant Standards
IES LM-79-2008
ANSI C82.77-2017
Prepared For
RAB Lighting Inc.
Prepared By
Dongguan New Testing Centre Co., Ltd.
Prepare by: Review by:
Engineer: Alan Wang Technical Lead: Vincent Yuan
Date: 2020-12-16 Issue Date: 2020-12-16
Revised Date: N/A
Page 2
TESTING NVLAP LAB CODE 600150-0
Laboratory: Dongguan New Testing Centre Co., Ltd Address: 3F, No. 1 the 1st North Industry Road, Songshan Lake Science & Technology Park, Dongguan,
Guangdong, China
Tel: 86-769-22212079
Website: http://www.ntc-cert.com
Report No: NTCLR20120116
Report Version: V1.4
Page 2 of 15
1.0 Test Summary
DLC Technical Requirements V5.1
Outdoor – Non-Cutoff and Semi-Cutoff Wall-Mounted Area Luminaires
Requirement Category Test Method Requirements Test Value
Luminaire Output (lm)
(Goniophotometer – Section 4.2) (0°-180° zones) IES LM-79-2008 N/A 1838.7
Minimum Luminaire Efficacy (lm/W)
(Goniophotometer – Section 4.2) (0°-180° zones) IES LM-79-2008 N/A 148.64
Luminaire Output (lm)
(Goniophotometer – Section 4.2) (0°-90° zones) IES LM-79-2008 300 1480.1
Minimum Luminaire Efficacy (lm/W)
(Goniophotometer – Section 4.2) (0-90° zones) IES LM-79-2008
Standard
105
Premium
120 119.65
Power (Input Wattage) (W)
(Goniophotometer – Section 4.2) IES LM-79-2008 Worst Case 12.37
Total Harmonic Distortion (A%)
(THD & PF – Section 4.3) ANSI C82.77:2014
20.00% 120V 9.52
20.00% 277V 13.91
Power Factor
(THD & PF – Section 4.3) ANSI C82.77:2014
0.9 120V 0.9841
0.9 277V 0.9009
Allowable CCTs* (K)
(Integrating Sphere – Section 4.1) IES LM-79-2008
7 steps 3985±275 3988
4 steps 3985±154 3988
Minimum CRI
(Integrating Sphere – Section 4.1)
IES LM-79-2008
CIE13.3-1995 ≥70 71.9
Minimum R9
(Integrating Sphere – Section 4.1)
IES LM-79-2008
CIE13.3-1995 ≥-40 -18
Minimum Rf
(Integrating Sphere – Section 4.1) ANSI/IES TM-30-18 ≥70 76
Minimum Rg
(Integrating Sphere – Section 4.1) ANSI/IES TM-30-18 ≥89 96
IES Rcs,h1
(Integrating Sphere – Section 4.1) ANSI/IES TM-30-18 -18%≤IES Rcs,h1≤+23% -14%
Zonal Lumen Requirement (80°-90°)
(Goniophotometer – Section 4.2) IES LM-79-2008 ≤10% 9.86%
Input Voltage (V)
(Goniophotometer – Section 4.2) IES LM-79-2008
Worst Cast 120.0
(Goniophotometer – Section 4.2) Non-Worst Case 277.0
Input Current (A)
(Goniophotometer – Section 4.2) IES LM-79-2008
Worst Case 0.1043
(Goniophotometer – Section 4.2) Non-Worst Case 0.0049
Power (Input Wattage – W)
(Goniophotometer – Section 4.2) IES LM-79-2008
Worst Case 12.37
(Goniophotometer – Section 4.2) Non-Worst Case 12.31
Page 3
TESTING NVLAP LAB CODE 600150-0
Laboratory: Dongguan New Testing Centre Co., Ltd Address: 3F, No. 1 the 1st North Industry Road, Songshan Lake Science & Technology Park, Dongguan,
Guangdong, China
Tel: 86-769-22212079
Website: http://www.ntc-cert.com
Report No: NTCLR20120116
Report Version: V1.4
Page 3 of 15
2.0 Test List
Test Item Test Test Date Model Number Sample No.
1 Integrating Sphere Test 2020-12-16 BRISKS17L-740 201207011-S1
2 Goniophotometer Test 2020-12-16 BRISKS17L-740 201207011-S1
3 THD and PF Test 2020-12-16 BRISKS17L-740 201207011-S1
Remark (If any)
1. The results contained in this report pertain only to the tested samples.
2. This report shall not be reproduced, no limited part or full, without approval of Dongguan New Testing
Centre Co., Ltd.
3. This report does not imply product certification, approval, or endorsement by NVLAP, or any agency of the
Federal Government.
3.0 Product Description
Luminaire Description: Wall Pack Light, Model No. BRISKS17L-740, 4000K
Electrical Specification: 120-277Vac, 50/60Hz, 14W
Photos of Luminaire Characteristics
Page 4
TESTING NVLAP LAB CODE 600150-0
Laboratory: Dongguan New Testing Centre Co., Ltd Address: 3F, No. 1 the 1st North Industry Road, Songshan Lake Science & Technology Park, Dongguan,
Guangdong, China
Tel: 86-769-22212079
Website: http://www.ntc-cert.com
Report No: NTCLR20120116
Report Version: V1.4
Page 4 of 15
4.0 LM-79 Measurement and Test Results
4.1 Integrating Sphere Test
Model No. BRISKS17L-740 Sample ID 201207011-S1
Operate time
(Min.) 10
Stabilization time
(Min.) 60
Temperature
(°C) 25.4
Humidity
(%RH) 41.0
Test Method
The Samples were tested according to the IES LM-79-2008.
Photometric parameters were measured using an integrating sphere, a spectroradiometer and software. The ambient
temperature condition inside the sphere was maintained at 25±1°C.
The sample measurements were made using a spectroradiometer connected by a fiber optic cable and detector through
the detector port of the integrating sphere.
The voltage of an AC power supply (RMS voltage) or DC power supply (instantaneous voltage) applied to the device
under test shall be regulated to within ±0.2 percent under load.
The sample was measured using 4π geometry and operated at rated voltage and was stabilized before measurement.
Chromaticity coordinates, correlated color temperature and color rendering index were calculated from the spectral
radiant flux measurements taken at 1 nm intervals over the range of 380 to 780nm.
Test Result
Voltage (Vac) Frequency (Hz) Current (A) Power (W) Power Factor
120.0 60 0.1043 12.37 0.9841
277.0 60 0.0049 12.31 0.9009
CCT (K) CRI R9 Duv Rf Rg IES Rcs,h1
3988 71.9 -18 -0.0003 76 96 -14%
Page 5
TESTING NVLAP LAB CODE 600150-0
Laboratory: Dongguan New Testing Centre Co., Ltd Address: 3F, No. 1 the 1st North Industry Road, Songshan Lake Science & Technology Park, Dongguan,
Guangdong, China
Tel: 86-769-22212079
Website: http://www.ntc-cert.com
Report No: NTCLR20120116
Report Version: V1.4
Page 5 of 15
4.1 Integrating Sphere Test
Page 6
TESTING NVLAP LAB CODE 600150-0
Laboratory: Dongguan New Testing Centre Co., Ltd Address: 3F, No. 1 the 1st North Industry Road, Songshan Lake Science & Technology Park, Dongguan,
Guangdong, China
Tel: 86-769-22212079
Website: http://www.ntc-cert.com
Report No: NTCLR20120116
Report Version: V1.4
Page 6 of 15
4.1 Integrating Sphere Test
x
y
u ' R a 73
v ' R 9 -18
Notes:CIE 13.3-1995
(CRI)
0.4381
0.4080
0.2496
0.5231
This is a recommended method fordisplaying ANSI/IES TM-30-18information.
0
10
20
30
40
50
60
70
80
90
100
CES
01C
ES03
CES
05C
ES07
CES
09C
ES11
CES
13C
ES15
CES
17C
ES19
CES
21C
ES23
CES
25C
ES27
CES
29C
ES31
CES
33C
ES35
CES
37C
ES39
CES
41C
ES43
CES
45C
ES47
CES
49C
ES51
CES
53C
ES55
CES
57C
ES59
CES
61C
ES63
CES
65C
ES67
CES
69C
ES71
CES
73C
ES75
CES
77C
ES79
CES
81C
ES83
CES
85C
ES87
CES
89C
ES91
CES
93C
ES95
CES
97C
ES99
Co
lor
Sam
ple
Fid
elit
y (R
f,C
ESi)
380 430 480 530 580 630 680 730 780
Rad
ian
t P
ow
er
(Eq
ua
l Lu
min
ous
Flu
x)
Wavelength (nm)
Reference Test
-0.0
2
0.1
0 0.1
9
0.1
5
0.0
9
-0.0
5
-0.1
4
-0.0
7
0.0
1
0.1
6 0.2
5
0.1
4
0.0
0
-0.1
3
-0.1
7
-0.2
0
-0.5
-0.4
-0.3
-0.2
-0.1
0.0
0.1
0.2
0.3
0.4
0.5
Loca
l Hue
Shi
ft (R
hs,hj)
74 7363
7585 85
7884 81
7065
74
8578 74 74
0102030405060708090
100
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Loca
l Col
or F
idel
ity
(Rf,
hj)
Hue-Angle Bin (j)
-14
%
-12
% -4%
5% 8
% 8%
-1%
-7%
-12
%
-12
% -6%
7% 9% 11%
1%
-7%
-40%
-30%
-20%
-10%
0%
10%
20%
30%
40%
Loca
l Ch
rom
a Sh
ift
(Rcs
,hj)
-20%
20%
1
2
3
45
16
6
7
8
9
10 15
11
12 13
14 Duv
76
CCT
96
0.0014
RgRf
3012 K
Page 7
TESTING NVLAP LAB CODE 600150-0
Laboratory: Dongguan New Testing Centre Co., Ltd Address: 3F, No. 1 the 1st North Industry Road, Songshan Lake Science & Technology Park, Dongguan,
Guangdong, China
Tel: 86-769-22212079
Website: http://www.ntc-cert.com
Report No: NTCLR20120116
Report Version: V1.4
Page 7 of 15
4.0 LM-79 Measurement and Test Results
4.2 Goniophotometer Test
Model No. BRISKS17L-740 Sample ID 201207011-S1
Operate time
(Min.) 30
Stabilization time
(Min.) 60
Temperature
(°C) 25.3
Humidity
(%RH) 47.3
Test Method
The Samples were tested according to the IES LM-79-2008.
Photometric parameters were measured using a type C goniophotometer and software.
The ambient temperature shall be maintained at 25±1°C, measured at a point not more than 1 m from the sample and
at the same height as the sample.
The voltage of an AC power supply (RMS voltage) or DC power supply (instantaneous voltage) applied to the device
under test shall be regulated to within ±0.2 percent under load.
The samples were operated at rated voltage and was stabilized before measurement. Luminous flux, luminaire
efficacy, zonal lumen were calculated from the software taken at 1.0° vertical intervals and 15° horizontal intervals.
Test Conditions
Condition Voltage (Vac) Frequency (Hz) Current (A) Power (W) Power Factor
WORST CASE 120.0 60 0.1043 12.37 0.9841
NON-WORST CASE 277.0 60 0.0049 12.31 0.9009
Test Result
Result
Type Flux (lm)
Field Angle (10%) Beam Angle (50%) Luminous
Efficacy
(lm/W)
Zonal Lumen
Requirement
(80°-90°)
BUG
Rating C0-180 C90-270 C0-180 C90-270
0°-180°
zones 1838.7 120.5 120.5 34.6 97.6 148.64 7.90% B1-U3-G2
0°-90°
zones 1480.1 120.5 120.5 34.6 97.6 119.65 9.86% B1-U3-G2
Page 8
TESTING NVLAP LAB CODE 600150-0
Laboratory: Dongguan New Testing Centre Co., Ltd Address: 3F, No. 1 the 1st North Industry Road, Songshan Lake Science & Technology Park, Dongguan,
Guangdong, China
Tel: 86-769-22212079
Website: http://www.ntc-cert.com
Report No: NTCLR20120116
Report Version: V1.4
Page 8 of 15
4.2 Goniophotometer Test
Lighting Distribution Curve
Isolux Plot
Page 9
TESTING NVLAP LAB CODE 600150-0
Laboratory: Dongguan New Testing Centre Co., Ltd Address: 3F, No. 1 the 1st North Industry Road, Songshan Lake Science & Technology Park, Dongguan,
Guangdong, China
Tel: 86-769-22212079
Website: http://www.ntc-cert.com
Report No: NTCLR20120116
Report Version: V1.4
Page 9 of 15
4.2 Goniophotometer Test
Zonal Lumen Summary
Zonal (lm) Total (lm) Percent0-10 39.77 0-10 39.77 2.16%10-20 112.39 0-20 152.16 8.28%20-30 165.18 0-30 317.34 17.26%30-40 195.84 0-40 513.18 27.91%40-50 211.74 0-50 724.92 39.43%50-60 217.01 0-60 941.93 51.23%60-70 208.60 0-70 1150.53 62.57%70-80 183.55 0-80 1334.08 72.56%80-90 146.01 0-90 1480.09 80.50%90-100 112.44 0-100 1592.53 86.61%100-110 85.25 0-110 1677.78 91.25%110-120 62.06 0-120 1739.84 94.63%120-130 43.24 0-130 1783.08 96.98%130-140 28.21 0-140 1811.29 98.51%140-150 16.61 0-150 1827.90 99.42%150-160 7.93 0-160 1835.83 99.85%160-170 2.56 0-170 1838.39 99.99%170-180 0.26 0-180 1838.65 100.00%
Page 10
TESTING NVLAP LAB CODE 600150-0
Laboratory: Dongguan New Testing Centre Co., Ltd Address: 3F, No. 1 the 1st North Industry Road, Songshan Lake Science & Technology Park, Dongguan,
Guangdong, China
Tel: 86-769-22212079
Website: http://www.ntc-cert.com
Report No: NTCLR20120116
Report Version: V1.4
Page 10 of 15
4.2 Goniophotometer Test
LCS/UBG
Page 11
TESTING NVLAP LAB CODE 600150-0
Laboratory: Dongguan New Testing Centre Co., Ltd Address: 3F, No. 1 the 1st North Industry Road, Songshan Lake Science & Technology Park, Dongguan,
Guangdong, China
Tel: 86-769-22212079
Website: http://www.ntc-cert.com
Report No: NTCLR20120116
Report Version: V1.4
Page 11 of 15
4.2 Goniophotometer Test
Coefficients of Utilization
Isolines
Page 12
TESTING NVLAP LAB CODE 600150-0
Laboratory: Dongguan New Testing Centre Co., Ltd Address: 3F, No. 1 the 1st North Industry Road, Songshan Lake Science & Technology Park, Dongguan,
Guangdong, China
Tel: 86-769-22212079
Website: http://www.ntc-cert.com
Report No: NTCLR20120116
Report Version: V1.4
Page 12 of 15
4.2 Goniophotometer Test
Luminous Distribution Intensity Data
Page 13
TESTING NVLAP LAB CODE 600150-0
Laboratory: Dongguan New Testing Centre Co., Ltd Address: 3F, No. 1 the 1st North Industry Road, Songshan Lake Science & Technology Park, Dongguan,
Guangdong, China
Tel: 86-769-22212079
Website: http://www.ntc-cert.com
Report No: NTCLR20120116
Report Version: V1.4
Page 13 of 15
Page 14
TESTING NVLAP LAB CODE 600150-0
Laboratory: Dongguan New Testing Centre Co., Ltd Address: 3F, No. 1 the 1st North Industry Road, Songshan Lake Science & Technology Park, Dongguan,
Guangdong, China
Tel: 86-769-22212079
Website: http://www.ntc-cert.com
Report No: NTCLR20120116
Report Version: V1.4
Page 14 of 15
4.0 LM-79 Measurement and Test Results
4.3 THD and PF Test
Model No. BRISKS17L-740 Sample ID 201207011-S1
Temperature
(°C) 25.4
Humidity
(%RH) 41.0
Test Method
The samples were tested according to the ANSI C82.77:2014
The total harmonic distortion shall be measured to the 40th order.
The ambient temperature shall be maintained at 25±1°C. The sample measurements were made using a digital power
meter and power supply. The sample was operated at rated voltage and was stabilized before measurement. The total
harmonic distortion was calculated.
Test Results
Voltage (Vac) Frequency (Hz) Current (A) Power (W) Power Factor iTHD(%)
120.0 60 0.1043 12.37 0.9841 9.52
277.0 60 0.0049 12.31 0.9009 13.91
Page 15
TESTING NVLAP LAB CODE 600150-0
Laboratory: Dongguan New Testing Centre Co., Ltd Address: 3F, No. 1 the 1st North Industry Road, Songshan Lake Science & Technology Park, Dongguan,
Guangdong, China
Tel: 86-769-22212079
Website: http://www.ntc-cert.com
Report No: NTCLR20120116
Report Version: V1.4
Page 15 of 15
5.0 Equipment List:
Equipment ID Equipment Name Last Cal. Due Cal.
NTC-F01-001 Goniophotometer System 2020-11-12 2021-11-11
NTC-F01-006 2.0 meter Integrating Sphere 2020-11-12 2021-11-11
NTC-F01-012 Standard Lamp 2020-11-12 2021-11-11
NTC-F01-013 Standard Lamp 2020-11-12 2021-11-11
NTC-F01-031 Digital Power Meter 2020-08-22 2021-08-21
NTC-F01-019 Temperature & Humidity Meter 2020-11-13 2021-11-12
**********End of Report**********