Elite Electronic Engineering, Inc. 1516 Centre Circle Downers Grove, IL 60515 630-495-9770 www.elitetest.com NOTE: FOR ELITE CUSTOMER USE ONLY. Information listed here is subject to revision without notice. Actual chamber performance will depend on test item and specification requirements. Contact Elite for current test equipment information and test application assistance. EMC CHAMBER DESCRIPTION TEST SUITE 22 Page 1 of 17 Test Room ID: R22A Description: Semi-Anechoic Shielded Whole Vehicle Test Enclosure Primary Testing Uses: Automotive, MIL-STD Dimensions: 21.30m x 10.67m x 5.49m (70ft. x 33ft. x 18ft.) [see Figure ‐ 4 below] Door Opening: 4.88m x 4.88m (16ft. x 16ft.) Construction: 3oz. Copper RF absorber placed on all four walls and the ceiling RF hardened Camera systems used for monitoring for susceptibility test Ground Plane Dimensions: No table mount ground plane 19.51m x 6.55m (64.0ft x 21.5ft) accessible ground plane on floor of chamber Room Filters: (1) 30A DC Filtered Line Power Availability: 230VAC (Delta), 60Hz, 3Phase, 30 Amp 120VAC, 60Hz, 1Phase 30 Amp 115VAC 60Hz 1Phase 15 Amp outlets 480VAC 60Hz 3Phase 100 Amp available at enclosure Note: Other power arrangements are available upon request. Ventilation: (3) 10,000CFM Fans exhausting outside of enclosure. (1) 40in by 30in windows with window flaps for rain protection. (2) External window flaps adjusted from outside for rain protection. (2) 3ft by 3ft Louvered Roof Vents. Exhaust Outlets: (2) 12in diameter (stainless steel pipe through enclosure ceiling.) 16ft above the floor (1) 5 ¼ in diameter (galvanized steel pipe through east side of enclosure)
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Elite Electronic Engineering, Inc. 1516 Centre Circle Downers Grove, IL 60515 630-495-9770 www.elitetest.com
NOTE: FOR ELITE CUSTOMER USE ONLY. Information listed here is subject to revision without notice. Actual chamber performance will depend on test item and specification requirements. Contact Elite for current test equipment information and test application assistance.
EMC CHAMBER DESCRIPTION TEST SUITE 22
Page 1 of 17
Test Room ID: R22A
Description: Semi-Anechoic Shielded Whole Vehicle Test Enclosure
Primary Testing Uses: Automotive, MIL-STD
Dimensions: 21.30m x 10.67m x 5.49m (70ft. x 33ft. x 18ft.) [see Figure ‐ 4 below] Door Opening: 4.88m x 4.88m (16ft. x 16ft.)
Construction: 3oz. Copper RF absorber placed on all four walls and the ceiling RF hardened Camera systems used for monitoring for susceptibility test
Ground Plane Dimensions: No table mount ground plane 19.51m x 6.55m (64.0ft x 21.5ft) accessible ground plane on floor of chamber
Room Filters: (1) 30A DC Filtered Line
Power Availability:
230VAC (Delta), 60Hz, 3Phase, 30 Amp 120VAC, 60Hz, 1Phase 30 Amp 115VAC 60Hz 1Phase 15 Amp outlets 480VAC 60Hz 3Phase 100 Amp available at enclosure Note: Other power arrangements are available upon request.
Ventilation:
(3) 10,000CFM Fans exhausting outside of enclosure. (1) 40in by 30in windows with window flaps for rain protection. (2) External window flaps adjusted from outside for rain protection. (2) 3ft by 3ft Louvered Roof Vents.
Exhaust Outlets: (2) 12in diameter (stainless steel pipe through enclosure ceiling.) 16ft above the floor (1) 5 ¼ in diameter (galvanized steel pipe through east side of enclosure)
Elite Electronic Engineering, Inc. 1516 Centre Circle Downers Grove, IL 60515 630-495-9770 www.elitetest.com
NOTE: FOR ELITE CUSTOMER USE ONLY. Information listed here is subject to revision without notice. Actual chamber performance will depend on test item and specification requirements. Contact Elite for current test equipment information and test application assistance.
EMC CHAMBER DESCRIPTION TEST SUITE 22
Page 2 of 17
Test Room ID: R22P
Description: Shielded Monitor Enclosure
Primary Testing Uses: Automotive, MIL-STD
Dimensions: 10.67m x 5.18m x 3.05m (35ft. x 17ft. x 10ft.) [see Figure ‐ 4 below]
Construction: 3oz. Copper Continuous Copper Tape for Ground Plate Bonding
Ground Plane Dimensions: 2.44m x 0.76m x 0.78mm (8ft. x 2.5ft. x 0.031in.) [see Figure ‐ 4 below]
Room Filters: (1) 30A DC Filtered Line
Power Availability: 208VAC, 60Hz, 3Phase, 30A Filtered AC Power 115VAC, 60Hz, 1Phase, 15A Outlets Note: Other power arrangements are available upon request.
Distance from Cable Tunnel to front of Ground Plane:
76.2cm (30in)
Elite Electronic Engineering, Inc. 1516 Centre Circle Downers Grove, IL 60515 630-495-9770 www.elitetest.com
NOTE: FOR ELITE CUSTOMER USE ONLY. Information listed here is subject to revision without notice. Actual chamber performance will depend on test item and specification requirements. Contact Elite for current test equipment information and test application assistance.
EMC CHAMBER DESCRIPTION TEST SUITE 22
Page 3 of 17
Figure – 1: Room 22A (Test Room)
Figure – 2: Room 22A (Test Room)
Elite Electronic Engineering, Inc. 1516 Centre Circle Downers Grove, IL 60515 630-495-9770 www.elitetest.com
NOTE: FOR ELITE CUSTOMER USE ONLY. Information listed here is subject to revision without notice. Actual chamber performance will depend on test item and specification requirements. Contact Elite for current test equipment information and test application assistance.
EMC CHAMBER DESCRIPTION TEST SUITE 22
Page 4 of 17
Figure – 3: Room 22P (Monitor Room)
Elite Electronic Engineering, Inc. 1516 Centre Circle Downers Grove, IL 60515 630-495-9770 www.elitetest.com
NOTE: FOR ELITE CUSTOMER USE ONLY. Information listed here is subject to revision without notice. Actual chamber performance will depend on test item and specification requirements. Contact Elite for current test equipment information and test application assistance.
Elite Electronic Engineering, Inc. 1516 Centre Circle Downers Grove, IL 60515 630-495-9770 www.elitetest.com
NOTE: FOR ELITE CUSTOMER USE ONLY. Information listed here is subject to revision without notice. Actual chamber performance will depend on test item and specification requirements. Contact Elite for current test equipment information and test application assistance.
EMC CHAMBER DESCRIPTION TEST SUITE 22
Page 6 of 17
Figure - 5: Room 22A (Test Room Ventilation)
70'
33'
17'
35'
Ceiling height - 18'Room ID: R22A
Room ID: R22P
15.5'
56'
12in Diameter
Exhaust Outlet
(stainless steel)
16ft above floor
(66in through
chamber & roof)
39' 30'
4ft
Door
Door
Test Chamber door = 197" Tall
= 196" wide
5¼ in Dia
Side exhaust
outlet 30in
long
3ft
Door
3 – 40in by 30in windows
(3 fans @ 10,000CFM each)
40" by 30" Window
Open for Ventilation
3' x 3'
square
roof vent
3' x 3'
square
roof vent
45'
Elite Electronic Engineering, Inc. 1516 Centre Circle Downers Grove, IL 60515 630-495-9770 www.elitetest.com
NOTE: FOR ELITE CUSTOMER USE ONLY. Information listed here is subject to revision without notice. Actual chamber performance will depend on test item and specification requirements. Contact Elite for current test equipment information and test application assistance.
EMC CHAMBER DESCRIPTION TEST SUITE 22
Page 7 of 17
Figure – 6: Plate 1
Elite Electronic Engineering, Inc. 1516 Centre Circle Downers Grove, IL 60515 630-495-9770 www.elitetest.com
NOTE: FOR ELITE CUSTOMER USE ONLY. Information listed here is subject to revision without notice. Actual chamber performance will depend on test item and specification requirements. Contact Elite for current test equipment information and test application assistance.
EMC CHAMBER DESCRIPTION TEST SUITE 22
Page 8 of 17
Figure – 7: Plate 1 Dimensions
11
11
All dimensions are in inches
3.25 2.5 2.38
1
4.13
3.63
1.5 dia.
1.5 dia.
.88 dia.88 dia .5 dia
Elite Electronic Engineering, Inc. 1516 Centre Circle Downers Grove, IL 60515 630-495-9770 www.elitetest.com
NOTE: FOR ELITE CUSTOMER USE ONLY. Information listed here is subject to revision without notice. Actual chamber performance will depend on test item and specification requirements. Contact Elite for current test equipment information and test application assistance.
EMC CHAMBER DESCRIPTION TEST SUITE 22
Page 9 of 17
Figure – 8: Plate 2
Elite Electronic Engineering, Inc. 1516 Centre Circle Downers Grove, IL 60515 630-495-9770 www.elitetest.com
NOTE: FOR ELITE CUSTOMER USE ONLY. Information listed here is subject to revision without notice. Actual chamber performance will depend on test item and specification requirements. Contact Elite for current test equipment information and test application assistance.
EMC CHAMBER DESCRIPTION TEST SUITE 22
Page 10 of 17
Figure – 9: Plate 2 Dimensions
11
11
All dimensions are in inches
3.38 3.38
1.5 1.5
2.38 2.13 2.13 2
6.63
4.13
2
2.52.752.75
1.5 dia. 1.5 dia.
.5 dia.
All holes are .88 dia. unless otherwise noted.
Elite Electronic Engineering, Inc. 1516 Centre Circle Downers Grove, IL 60515 630-495-9770 www.elitetest.com
NOTE: FOR ELITE CUSTOMER USE ONLY. Information listed here is subject to revision without notice. Actual chamber performance will depend on test item and specification requirements. Contact Elite for current test equipment information and test application assistance.
EMC CHAMBER DESCRIPTION TEST SUITE 22
Page 11 of 17
Figure – 10: Plate 3
Elite Electronic Engineering, Inc. 1516 Centre Circle Downers Grove, IL 60515 630-495-9770 www.elitetest.com
NOTE: FOR ELITE CUSTOMER USE ONLY. Information listed here is subject to revision without notice. Actual chamber performance will depend on test item and specification requirements. Contact Elite for current test equipment information and test application assistance.
EMC CHAMBER DESCRIPTION TEST SUITE 22
Page 12 of 17
Figure – 11 Plate 3 Dimensions
11
11
All dimensions are in inches
2.13
2.88 3 2.81
5.5
3.75
.88 dia.
2 dia.
Elite Electronic Engineering, Inc. 1516 Centre Circle Downers Grove, IL 60515 630-495-9770 www.elitetest.com
NOTE: FOR ELITE CUSTOMER USE ONLY. Information listed here is subject to revision without notice. Actual chamber performance will depend on test item and specification requirements. Contact Elite for current test equipment information and test application assistance.
EMC CHAMBER DESCRIPTION TEST SUITE 22
Page 13 of 17
Figure – 12: Plate 4
Elite Electronic Engineering, Inc. 1516 Centre Circle Downers Grove, IL 60515 630-495-9770 www.elitetest.com
NOTE: FOR ELITE CUSTOMER USE ONLY. Information listed here is subject to revision without notice. Actual chamber performance will depend on test item and specification requirements. Contact Elite for current test equipment information and test application assistance.
EMC CHAMBER DESCRIPTION TEST SUITE 22
Page 14 of 17
Figure – 13: Plate 4 Dimensions
19 3/8"
19 3/8"
0.9375"
5.3125"
9.625"
13.875"
18.375"
1.000"
5.375"
9.6875"
14.00"
18.375"
1.000"
5.375"
9.8125"
14.1875"
18.4375"
5.3125"
1.000"
9.6875"
14.0"
18.3125"
16" x 16" Usable Area for
Connectors
= 5/16" Holes Drilled in Plate for Mounting of Plate to Chamber Wall
Elite Electronic Engineering, Inc. 1516 Centre Circle Downers Grove, IL 60515 630-495-9770 www.elitetest.com
NOTE: FOR ELITE CUSTOMER USE ONLY. Information listed here is subject to revision without notice. Actual chamber performance will depend on test item and specification requirements. Contact Elite for current test equipment information and test application assistance.
EMC CHAMBER DESCRIPTION TEST SUITE 22
Page 15 of 17
Figure – 14: Shielded Enclosure Door
Elite Electronic Engineering, Inc. 1516 Centre Circle Downers Grove, IL 60515 630-495-9770 www.elitetest.com
NOTE: FOR ELITE CUSTOMER USE ONLY. Information listed here is subject to revision without notice. Actual chamber performance will depend on test item and specification requirements. Contact Elite for current test equipment information and test application assistance.
EMC CHAMBER DESCRIPTION TEST SUITE 22
Page 16 of 17
Note: The degree measurements were taken at break points in the concrete with a digital level. The overall degree indicated was calculated, based on the high and overall
length measurements using a laser level. With the flat to door measurement (36.75 inches) and door to road measurement (28 inches).
Road to door measurements
Road/door = arc tan (28/636) = 2.5° 14ft to door = arc tan (21.5/468) = 2.6° 27ft to door = arc tan (11/312) = 2.0°
Road/14ft = arc tan (6.5/168) = 2.2° 14ft/27ft = arc tan (10.5/156) = 3.8° 27ft/54ft = arc tan (11/312) = 2.0°
Figure – 15: Driveway & Ramp Grade
Overhead
Door Frame
Driveway 54 ft 2.5 degrees
Ramp 60 ft 2.9 degrees
(approx 6.125" rise in 10') Flat 45 ft
13' 10"Vehicle
Chamber
2.28° 4.04° 3.49° 3.37°
1.71°
16ft 33ft50ft 60ft
0ft
Garage
Door
Chamber
Door
Road1.40° 1.91°/3.35°
4.18° 3.32°/4.75° 2.02°
7ft14ft 22ft 27ft 40ft
54ft
1.71°
Concrete breaks/strain relief
Concrete breaks/strain relief
Elite Electronic Engineering, Inc. 1516 Centre Circle Downers Grove, IL 60515 630-495-9770 www.elitetest.com