TEST REPORT REPORT NO. ....…..…….….... : HST200909-1844-CE-E EQUIPMENT UNDER TEST… : Automatic Voltage Regulator MODEL NAME ............... .…... : AVR 500, AVR 600, AVR 700, AVR 750, AVR 800, AVR 850, AVR 1000, AVR 1200, AVR 1500, AVR 1600, AVR 2000 APPLICANT NAME…….. .….. : Guangdong East Power Co., Ltd. APPLICANT ADDRESS……... : No. 6 Northern Industry Road, Songshan Lake Sci&Tech Industry Park, Dongguan, P. R. China CLASSIFICATION……….….. : CE-EMC PREPARED BY…………. .….. : Guangzhou Huesent Testing Service Co., Ltd.
41
Embed
TEST REPORT - eastups.com CE-EMC.pdf · TEST REPORT REPORT NO ... EQUIPMENT UNDER TEST… : Automatic Voltage Regulator MODEL ... details please refer to clause 7.4 in this report.
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
TEST REPORT
REPORT NO. ....…..…….….... : HST200909-1844-CE-E
EQUIPMENT UNDER TEST… : Automatic Voltage Regulator
MODEL NAME ............... .…... :
AVR 500, AVR 600, AVR 700, AVR 750, AVR
800, AVR 850, AVR 1000, AVR 1200, AVR
1500, AVR 1600, AVR 2000
APPLICANT NAME…….. .….. : Guangdong East Power Co., Ltd.
APPLICANT ADDRESS……... :No. 6 Northern Industry Road, Songshan Lake
Sci&Tech Industry Park, Dongguan, P. R. China
CLASSIFICATION……….….. : CE-EMC
PREPARED BY…………. .….. : Guangzhou Huesent Testing Service Co., Ltd.
Report Number: HST200909-1844-CE-E
Page 2 of 41
TABLE OF CONTENT
1 Verification of Conformity ................................................................................................ 4
2 Test Summary................................................................................................................. 5
3 System Description......................................................................................................... 7
4 Product Information ........................................................................................................ 7
5 Test Facility ..................................................................................................................... 7
6 Equipments Used During Test ........................................................................................ 8
Test Method: CISPR 16-2-1, 7.4.1, CISPR 16-1-2, 4.3
Class: Table 1 of EN 61000-6-3
Detector: Peak for pre-scan
Quasi-Peak and Average at frequency with maximum peak (150k-30MHz resolution bandwidth: 9kHz)
Test Date: Oct. 26, 2009
7.1.1. E.U.T. Operation Operating Environment:
Temperature: 25.0 C Humidity:60% RH Atmospheric Pressure:103.0kPa
EUT Operation: 1. Connect the EUT with load to the mains in 230VAC/50Hz. 2. Make sure EUT work normally in full load mode during the whole test.
Test at about 160 kHz was made over a range of 0.9 to 1.1 times the rated voltage in
order to check whether the level of disturbance varies considerably with the supply voltage. Test the EUT in work normally of normal operating status, since no considerably varies
found.
7.1.2. Test Setup
Report Number: HST200909-1844-CE-E
Page 10 of 41
7.1.3. Measurement Data
Pre-scan was performed with peak detected on both live and neutral cable. Quasi-peak & average measurements were performed on the neutral lines at the frequencies at which maximumu peak emission level were detected. Please see the attached Quasi-peak and Average test results.
Live Line
Peak Scan
Quasi-peak and Average measurement
Freq.
(MHz) Line
QP
(dBµV)
QP limit
(dBµV)
Margin
(dB)
AV
(dBµV)
AV limit
(dBµV)
Margin
(dB)
0.154 Live 41.3 65.9 -24.6 27.4 55.9 -28.5
0.5-5 Live <30 56 / <25 46 /
5-30 Live <30 60 / <25 50 /
Report Number: HST200909-1844-CE-E
Page 11 of 41
Neutral Line
Peak Scan
Quasi-peak and Average measurement
Freq.
(MHz) Line
QP
(dBµV)
QP limit
(dBµV)
Margin
(dB)
AV
(dBµV)
AV limit
(dBµV)
Margin
(dB)
0.15-0.5 Neutral <40 66-56 / <25 56-46 /
0.5-5 Neutral <30 56 / <25 46 /
5-30 Neutral <30 60 / <25 50 /
Report Number: HST200909-1844-CE-E
Page 12 of 41
7.1.4. Photograph
Report Number: HST200909-1844-CE-E
Page 13 of 41
7.2 Radiated Disturbance Test, 30M-1GHz
Test Requirement: EN 61000-6-3
Test Method: CISPR 16-2-3
Class: Table 1 of EN 61000-6-3
Frequency Range: 30MHz-1GHz
Detector: Peak for pre-scan
Quasi-Peak at frequency with maximum peak ( 30M-1GHz resolution bandwidth: 120kHz)
EUT Operation: 1. Connect the EUT with load to the mains in 230VAC/50Hz. 2. Make sure EUT work normally in full load mode during the whole test.
7.2.2. Measurement Setup
Example test arrangement for tabletop equipment ( radiated emission measurement )
Report Number: HST200909-1844-CE-E
Page 14 of 41
7.2.3. Measurement Data
Test in 230VAC/50Hz
Horizontal Curve
Peak Scan
Quasi-peak measurement
Frequency Level Transducer
Factor Limit Margin
MHz dBuV/m dB dBuV/m dB
141.72 25.4 8.8 40.0 -14.6
187.97 29.5 11.0 40.0 -10.5
191.97 29.5 11.1 40.0 -10.5
Note: The transducer factor includes antenna factor and cable loss.
Report Number: HST200909-1844-CE-E
Page 15 of 41
Test in 230VAC/50Hz
Vertical Curve
Peak Scan
Quasi-peak measurement
Frequency Level Transducer
Factor Limit Margin
MHz dBuV/m dB dBuV/m dB
136.73 30.6 8.7 40.0 -9.4
188.02 25.2 11.0 40.0 -14.8
Note: The transducer factor includes antenna factor and cable loss.
Report Number: HST200909-1844-CE-E
Page 16 of 41
Test in 120VAC/50Hz
Horizontal Curve
Peak Scan
Quasi-peak measurement
Frequency Level Transducer
Factor Limit Margin
MHz dBuV/m dB dBuV/m dB
120.3 25.7 8.6 40.0 -14.3
230-1000 <40 / 47 /
Note: The transducer factor includes antenna factor and cable loss.
Report Number: HST200909-1844-CE-E
Page 17 of 41
Test in 120VAC/50Hz
Vertical Curve
Peak Scan
Quasi-peak measurement
Frequency Level Transducer
Factor Limit Margin
MHz dBuV/m dB dBuV/m dB
30-230 <30 / 40 /
230-1000 <37 / 47 /
Note: The transducer factor includes antenna factor and cable loss.
Report Number: HST200909-1844-CE-E
Page 18 of 41
7.2.4. Photograph
Report Number: HST200909-1844-CE-E
Page 19 of 41
7.3 Harmonics Emission Test
Test Requirement: EN 61000-6-3
Test Method: IEC 61000-3-2
Frequency Range: 100Hz to 2kHz
Limits: Class A
Measure Time: 3 minutes.
Test Date: Oct. 26, 2009
7.3.1 E.U.T. Operation
Operating Environment:
Temperature(C): 25.0
Humidity(% RH): 60
Atmospheric Pressure (kpa): 103.0
EUT Operation:
1. Connect the EUT with load to the mains in 230VAC/50Hz.
2. Make sure EUT work normally in full load mode during the whole test.
Report Number: HST200909-1844-CE-E
Page 20 of 41
7.3.2 Measurement Data
TestVoltage:232.1V~ Power : 1125.3W Power factor: 1.000 Irms: 4.975A
Hn Ieff [A] Limit [A] Result Hn Ieff [A] Limit [A] Result
1 4.899 PASS 21 0.001 0.1071 PASS
2 0.003 1.0800 PASS 22 0.000 0.0836 PASS
3 0.086 2.3000 PASS 23 0.001 0.0978 PASS
4 0.001 0.4300 PASS 24 0.000 0.0767 PASS
5 0.007 1.1400 PASS 25 0.000 0.0900 PASS
6 0.001 0.3000 PASS 26 0.000 0.0708 PASS
7 0.013 0.7700 PASS 27 0.000 0.0833 PASS
8 0.001 0.2300 PASS 28 0.000 0.0657 PASS
9 0.003 0.4000 PASS 29 0.000 0.0776 PASS
10 0.000 0.18400 PASS 30 0.000 0.0613 PASS
11 0.004 0.3300 PASS 31 0.000 0.0726 PASS
12 0.000 0.1533 PASS 32 0.000 0.0575 PASS
13 0.002 0.2100 PASS 33 0.000 0.0682 PASS
14 0.000 0.1314 PASS 34 0.000 0.0541 PASS
15 0.002 0.1500 PASS 35 0.000 0.0643 PASS
16 0.000 0.1150 PASS 36 0.000 0.0511 PASS
17 0.001 0.1324 PASS 37 0.000 0.0608 PASS
18 0.000 0.1022 PASS 38 0.000 0.0484 PASS
19 0.001 0.1184 PASS 39 0.000 0.0577 PASS
20 0.000 0.0920 PASS 40 0.000 0.0540 PASS
Report Number: HST200909-1844-CE-E
Page 21 of 41
7.4 Flicker Test
Test Requirement: EN61000-6-3
Test Method: IEC 61000-3-3
Limit: Clause 4
Measure Time: 10 minutes
Test Date: Oct. 26, 2009
7.4.1 E.U.T. Operation
Operating Environment:
Temperature(C): 25.0
Humidity(% RH): 60
Atmospheric Pressure (kpa): 103.0
EUT Operation:
1. Connect the EUT with load to the mains in 230VAC/50Hz.
2. Make sure EUT work normally in full load mode during the whole test.
7.4.2 Measurement Data
EUT values
Zref =Ztest Zref =50%Ztest Limit Result
Pst 1.422 0.711 1.00 PASS*
Plt 0.621 0.3105 0.65 PASS*
dc [%] 0.87 0.435 3.30 PASS*
dmax [%] -10.77 -5.385 6.00 PASS*
dt [s] 0.01 0.01 0.50 PASS*
Note:
*: The applicant stated the impedance of the supply system (Zref) for the EUT should be 50% of
the test impedance Ztest (0.4ohm+j0.3ohm), i.e. the Zref shall be 0.2ohm+j0.15ohm
Report Number: HST200909-1844-CE-E
Page 22 of 41
More details about the Zref please refer the EN 61000-3-11 clause 6.1.3 listed as below:
Report Number: HST200909-1844-CE-E
Page 23 of 41
7.4.3 Photograph
Photograph of EUT’s set-up in the harmonic and flick tests is as follows:
Report Number: HST200909-1844-CE-E
Page 24 of 41
8 Immunity Test
8.1 Performance Criteria Description in EN 61000-6-1
Criterion A: The apparatus shall continue to operate as intended during and after the test. No
degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. The performance level may be replaced by a permissible loss of performance. If the minimum performance level or the permissible performance loss is not specified by the manufacturer, either of these may be derived from the product description and documentation and what the user may reasonably expect from the apparatus if used as intended.
Criterion B: The apparatus shall continue to operate as intended after the test. No degradation of
performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. The performance level may be replaced by a permissible loss of performance. During the test, degradation of performance is however allowed. No change of actual operating state or stored data is allowed. If the minimum performance level or the permissible performance loss is not specified by the manufacturer, either of these may be derived from the product description and documentation and what the user may reasonably expect from the apparatus if used as intended.
Criterion C:
Temporary loss of function is allowed, provided the function is self-recoverable or can be
restored by the operation of the controls.
Report Number: HST200909-1844-CE-E
Page 25 of 41
8.2 Electrostatic Discharge Immunity Test (ESD)
Test Requirement: EN 61000-6-1
Test Method: IEC 61000-4-2
Port: Enclosure
Test Level: ± 2, 4, 8 kV (Air Discharge)
± 2, 4 kV (Contact Discharge)
± 2, 4 kV (Indirect Discharge)
Characteristics of
Test Generator: 150pF/ 330Ω
Criterion require: B
Test Date: Oct. 27, 2009
8.2.1. Block Diagram of Test Setup
(The 470 k ohm resistors are installed per standard requirement)
Report Number: HST200909-1844-CE-E
Page 26 of 41
8.2.2. Test Procedure
The EUT was located 0.1 m minimum from all side of the HCP.
The support units were located 1 m minimum away from the EUT.
EUT worked with resistance load, and make sure EUT worked normally.
Active the communication function if the EUT has such port(s).
As per the requirement of EN 55024; applying direct contact discharge at the sides other
than front of EUT at minimum 50 discharges (25 positive and 25 negative) if applicable,
can’t be applied direct contact discharge side of EUT then the indirect discharge shall be
applied. One of the test points shall be subjected to at least 50 indirect discharge
(contact) to the front edge of horizontal coupling plane.
Other parts of EUT where it is not possible to perform contact discharge then selecting
appropriate points of EUT for air discharge, a minimum of 10 single air discharges shall be
applied.
The application of ESD to the contact of open connectors is not required.
Putting a mark on EUT to show tested points. The following test condition was followed
during the tests.
Note: As per the A2 to IEC 61000-4-2, a bleed resistor cable is connected between the