Test report 2012-3092-4628-REN Date of issue: February 1, 2012 Number of pages: 25 Prepared for: Barix GmbH Entwicklung Karlstrasse 49 Cust. ID: 1959-24998 D-78054 Villingen-Schwenningen Phone: 07720-807713 Fax: 07720-808048 E-Mail: [email protected]Contact: Mr. Braun Equipment under test: Name: Model: Manufacturer: Annuncicom 50 Barix GmbH The EUT has been modified during com- pliance testing. Date of tests: 01/09/2012 - 01/20/2012 Test specifications: Emission: EN 55022:2010 (Limit class: B) Immunity: EN 55024:2010 Test summary: Emission Tested port Limit class Result Conducted emissions at signal & telecommunication lines 150 kHz - 30 MHz Ethernet B Passed Radiated emissions - electromagnetic fields 30 MHz - 1000 MHz Enclosure B Passed Immunity to ... Tested port Test level Crit. Result Electrostatic discharge (ESD) Enclosure Air: 8 kV A Cont.: 4 kV A Passed Electromagnetic fields 80 MHz - 1000 MHz (AM) Enclosure 3 V/m A Passed Electrical fast transients (Burst) loud speaker, ethernet, line in 0.5 kV A Passed Surge LAN 1 kV A Passed Conducted RF disturbances 150 kHz - 80 MHz (AM) See inside test report 3 V A Passed Testing location: ELMAC GmbH Boschstraße 2 D-71149 Bondorf Phone: ++49(0)7457-9441-0 Fax: ++49(0)7457-9441-99 WWW: http://www.elmac.de/ E-Mail: [email protected]Tested by: February 1, 2012 Verified by: February 1, 2012 C. Eisen Date J. Bühne Date
25
Embed
Test report 2012-3092-4628-REN · Test report 2012-3092-4628-REN Date of issue: February 1, 2012 Number of pages: 25 Prepared for: Barix GmbH Entwicklung Karlstrasse 49 Cust. ID:
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Test report 2012-3092-4628-REN Date of issue: February 1, 2012Number of pages: 25
ELMAC GmbH informs the client that testing is done in accordance with the standard procedures stated under paragraph 2. All deviations will be listedseparately. The test results of this report exclusively refer to the specific sample tested under stated test conditions. ELMAC GmbH shall have no liabilityfor any deductions, inferences or generalisations drawn from the test results. This report must only be reproduced in full. Publications or reproductionsin the form of extracts have to be approved in written form by ELMAC GmbH.
ELMAC GmbH Test report 2012-3092-4628-REN Page 3/25
2. Test specifications
Emission
Document No. Title Limit class
EN 55022:2010CISPR 55022:2008, modifiedDIN EN 55022:2012
Information technology equipment - radio disturbance characteristics -Limits and methods of measurement
B
Immunity
Document No. Title Severity level
EN 55024:2010CISPR 24:2010DIN EN 55024:2011
Information technology equipment - Immunity characteristics - Limitsand methods of measurement
emvID: 3747
ELMAC GmbH Test report 2012-3092-4628-REN Page 4/25
3. Equipment Under Test (EUT)
Name Annuncicom
Model 50
S/N -
Manufacturer Barix GmbH
Kind/Type of EUT POE - Intercom device
Day of receipt 01/09/2012
Kind of EUT handling Plug-in During the tests: As table top equipment
Base unit covering the EUT -
Accessories(Part of the EUT)
-
Support equipment(Not part of the EUT)
Ethernetswitch type FS108P Netgear as POE sourceLaptop type Lifebook S7220 Fujitsu-SiemensNF-Generator type exstreamer 100 Barix
Connected cables and lines Name No of wires Length shield
All test equipment having an important influence on the certainty of the test results is incorporated into a system of regular calibration andmaintenance. The calibration system is a part of ELMAC's quality management system.
4.3. Measurement uncertainty
All EMC tests have a measurement uncertainty. The measurement uncertainty is a parameter related to a quantitative testing characterizingthe range of values that with a certain probability still can be assigned to the result. Commonly the measurement uncertainty is given so, thatthe named probability is 95 %.
In this Test Report, the measurement uncertainties are stated at each Emission test.
The measurement uncertainties for Immunity tests are available on request.
4.4. Perfomance criteria
If no other performance criteria specified in the standards listed in section 2. The performance criteria of EN 61326:1997 + A1:1998+A2:2001 section 6.5 are applied.
ELMAC GmbH Test report 2012-3092-4628-REN Page 6/25
5. Test Results
See next pages.
ELMAC GmbH Test report 2012-3092-4628-REN Page 7/25
- 2 0
- 1 5
- 1 0
- 5
0
5
1 0
1 5
2 0
2 5
3 0
3 5
4 0
4 5
5 0
5 5
6 0
1 5 0 k 3 0 0 4 0 0 5 0 0 8 0 0 1 M 2 M 3 M 4 M 5 M 6 8 1 0 M 2 0 M 3 0 M
Peg
el in
dB
µA
F r e q u e n z i n H z
E S C I 3 e iS ig P C L 2 5 E N 5 5 0 2 2 B
E N 5 5 0 2 2 B e i T K P Q P
E N 5 5 0 2 2 B e i T K P A V
E N 5 5 0 2 2 A e i T K P A V
5.1. Conducted emissions at signal & telecommunication lines150 kHz - 30 MHz
euSigID: 453
EUT: Annuncicom Kind of test: Emission50 Basic standard: EN 55022:2010
Date of test: 01/09/2012 Atm. press. 965 hPaTested by: CEPrescan: DoneFinal test: RenouncedTest site (final): Fully Anechoic Chamber EUT modified: NoAntenna distance: 3 m
Result: PassedLimit class: BRemarks:
QUASI-PEAK Detection
During the prescan there were not found any or only very low signals emitted by the EUT. Therefore the test of radiated emissions wasdone without using the Open Area Test Site (OATS). The limit margin is at least 10 dB.
Test equipment usedName Model Manufacturer S/N INV RemarksBiLog Antenna CBL6140A Schaffner 1118 219EMI TEST RECEIVER ESPI7 R&S 100090 359
ELMAC GmbH Test report 2012-3092-4628-REN Page 12/25
148.120000 21.4 H 18.6 40.0159.720000 23.2 H 16.8 40.0192.040000 26.3 H 13.7 40.0250.080000 23.6 H 23.4 47.0375.040000 36.3 H 10.7 47.0503.800000 30.6 H 16.4 47.0625.160000 33.2 H 13.8 47.0750.000000 36.1 H 10.9 47.0875.000000 33.8 H 13.2 47.0999.960000 38.5 H 8.5 47.0
ELMAC GmbH Test report 2012-3092-4628-REN Page 13/25
5.3. Electrostatic discharge (ESD)
idID: 2480
EUT: Annuncicom Kind of test: Immunity50 Basic standard: EN 61000-4-2:2009
At each test voltage at least 10 positive test pulses with a time interval of 1 s and 10 negative test pulses with a time interval of 1 swere carried out.
Test equipment usedName Model Manufacturer S/N INV RemarksESD Generator NSG 435 Schaffner 222 182
ELMAC GmbH Test report 2012-3092-4628-REN Page 14/25
ad 5.3. Electrostatic discharge (ESD)
idID: 2480
EUT: Annuncicom50
Air discharge • Contact discharge
Id-1.jpg
ELMAC GmbH Test report 2012-3092-4628-REN Page 15/25
ELMAC GmbH Test report 2012-3092-4628-REN Page 16/25
ad 5.4. Radio-frequency electromagnetic fields80 MHz - 1000 MHz
ifID: 4081
EUT: Annuncicom50
If-1.jpg
ELMAC GmbH Test report 2012-3092-4628-REN Page 17/25
ad 5.4. Radio-frequency electromagnetic fields80 MHz - 1000 MHz
ifID: 4081
EUT: Annuncicom50
If-2.jpg
ELMAC GmbH Test report 2012-3092-4628-REN Page 18/25
5.5. Electrical fast transients (Burst)
ibID: 2503
EUT: Annuncicom Kind of test: Immunity50 Basic standard: EN 61000-4-4:2004
Operation mode: 1 kHz streamEnvironment: Temp. 22 °C
Humidity 30 %Date of test: 01/09/2012 Atm. press. 965 hPaTested by: CE EUT modified: NoRequired perfor-mance criterion:
BResult: Passed
Remarks:
Coupling devicesand
Kind of coupling Tested cables/lines
Test
vol
tage
(kV
)
Pas
sed
Per
form
ance
crit
erio
nRemarks
Coupling devicenetwork(in each case un-symmetrically andasymmetrically)
Capacitivecoupling clamp(asymmetrically)
loud speaker, ethernet, line in 0.5 A
Notes:
Tested polarization: Positive + Negative (at each kind of coupling)Duration of test: 60 s at each polarity and kind of couplingTest puls: 5/50 ns; Zi = 50 OhmRepetition frequency: 5 kHz; at test level $ 4 kV: 2.5 kHz
Kind of coupling: s = symmetricallyu = unsymmetrically
Test puls: 1.2/50µs; Zi = 2 OhmPolarity: positive and negative at each test voltageNumber of test pulses: $ 6 at each test voltageTime interval between pulses: $10 sTested voltage steps: 0,5 / 1 kV, if max. test voltage = 1 kV
0,5 / 1 / 1,5 / 2 kV, if max. test voltage = 2 kV1 / 2 / 3 / 4 kV, if max. test voltage = 4 kV
Tested phase angels (at AC): 90°/180°/270°
Test equipment usedName Model Manufacturer S/N INV RemarksKombigenerator NSG 3040 TESEQ 097 446
ELMAC GmbH Test report 2012-3092-4628-REN Page 21/25
ad 5.6. Surge
isID: 2261
EUT: Annuncicom50
Is-1.jpg
ELMAC GmbH Test report 2012-3092-4628-REN Page 22/25