8 Low Voltage Products & Systems LV009 [SXU60009C0202] - June 2007 ABB Inc. • 888-385-22 • www.abb-control.com Color Type Part number Standard block Orange D 4/6.ADO 0199 035.16 Blue D 4/6.N.ADO 0199 036.17 Black D 4/6.ADO 0199 071.22 Red D 4/6.ADO 0199 069.00 Ivory D 4/6.ADO 0199 070.05 Yellow D 4/6.ADO 0199 039.22 Green D 4/6.ADO 0199 040.07 Solid wire Stranded wire Solid wire Stranded wire Characteristics Rated Pulse Pollution degree Rated Rated Wire size Current Voltage Wire size Wire stripping Recommended Recommended lenght (screw) screwdriver torque (screw) Protection Accessories Type Part numbers Standard block 6 mm. For multiple wire connections, the two wires need to be of the same gauge and nature (solid or stranded). Terminal block body material is UL 94 V0. Screw Terminal blocks Insulation Displacement ADO - Screw clamp DIN3 ADO side Screw side 0,34 - 1,5 mm² 0,2 - 4 mm² 22 - 16 AWG 22 - 10 AWG Spacing 6 mm +0,05 .238" () A circuit separator SCAD and 500 V (IEC) rated voltage are required with these accessories. (2) See column on right page : "Various applications". Grey Notes th. spa. spa. 8 or 0 099 336.20 074 78.25 End stop th. 9 mm BADL V0 End stop th. 0 mm BAM2 V2 End stop th. 0 mm BAM2 V0 V0 Rail 35 x 7,5 x PR3.Z2 Rail 35 x 5 x 2,3 PR4 Rail 35 x 5 x ,5 PR5 Other end stops, rails and accessories : see section on accessories. 0399 903.02 0206 351.16 0399 967.01 0174 300.17 0168 500.12 0168 700.22 D 4/6... .ADO R 4 6 7 2 2 3 5 9,5 mm 4 mm 0,5-0,8 Nm IP 20 .37" .6" 4.4-7. lb.in NEMA 0,2-4 mm² 22-0 AWG 22-0 AWG 0,22-4 mm² 22-0 AWG 22-0 AWG 0,34-,5 mm² 22-6 AWG 22-6 AWG 0,34-,5 mm² 22-6 AWG 22-6 AWG 000 V 600 V 600 V 8 kV 3 7,5 A 8 A 8 A ,5 mm² 0/6 AWG 0/6 AWG 4 8 20 5 RC65 RC60 2 RTM7 ADO 3 5 7 8 9 2 6 22 23 24 25 IEC UL CSA NFC DIN FEDAD 3 mm FEDAD 3 mm FEDAD 3 mm SCAD AL2 () 2 mm AL3 () 3 mm DCJ FC2 2 mm FC4 4 mm BJM6 32 A 2 BJM6 32 A 3 BJM6 32 A 4 BJM6 32 A 5 BJM6 32 A 0 BJMI6 32 A 2 BJMI6 32 A 3 BJMI6 32 A 4 BJMI6 32 A 5 BJMI6 32 A 0 BJS6 32 A 20 EV6 BJADO6.2 7,5 A 2 BJADO6.3 7,5 A 3 BJADO6.4 7,5 A 4 BJADO6.5 7,5 A 5 BJADO6.0 7,5 A 0 BJADO6.20 7,5 A 20 BJP6 35 A BJA6 32 A 0 BJDP (2) 50 A 6 <-> 6 BJDP3 (2) 70 A 6 <-> 2 BJDP4 (2) 50 A 6 <-> EL6 35 A PC6 35 A 2 PC6 35 A 3 PC6 35 A 4 PC6 35 A 0 EIP CBM5 0,5 mm CBM8 0,8 mm EP6 4 VSP6 AD2,5 24 A OUMAD OUPAD OUTAD OUTA EXAD2 CEADO.6 CEADOE 1 End section grey blue yellow 2 Separator grey 3 Test socket 4 Test device 5 Test plug 6 Assembled jumper bar (without IP20 protection) 7 Assembled jumper bar (with IP20 protection) 8 Jumper bar not assembled Post + screw + washer 11 Screwless jumper bar to be inserted into ADO jaw orange IP20 12 Pivoting jumper bar 13 Jumper bar for alternated jumping 14 Universal jumper bar 15 Connector plate 16 Comb type jumper bar Insulating tip 17 Shield connector 18 Protection label Screw for protection label 19 IDC jumper 20 Hand tool kit 21 Semi-automatic tool 22 Pneumatic tool kit 23 Replacement head kit 24 Extraction tool kit 25 Test connector R See section on markers marking method
41
Embed
Terminal blocks D 4/6 .ADO Insulation · 2018. 5. 9. · Black D 4/6.ADO 0199 071.22 Red D 4/6.ADO 0199 069.00 Ivory D 4/6.ADO 0199 070.05 Yellow D 4/6.ADO 0199 039.22 Green D 4/6.ADO
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
8 Low Voltage Products & Systems
LV009 [�SXU�60009C0202] - June 2007 ABB Inc. • 888-385-�22� • www.abb-control.com
Color Type Partnumber
Standard block Orange D4/6.ADO 0199035.16 Blue D4/6.N.ADO 0199036.17Black D4/6.ADO 0199071.22Red D4/6.ADO 0199069.00 Ivory D4/6.ADO 0199070.05Yellow D4/6.ADO 0199039.22Green D4/6.ADO 0199040.07
Standard block 6 mm. For multiple wire connections, the two wires need to be of the same gauge and nature (solid or stranded). Terminal block body material is UL 94 V0.
End stop th. 9 mm BADL V0 End stop th. �0 mm BAM2 V2 End stop th. �0 mm BAM2V0 V0 Rail 35 x 7,5 x � PR3.Z2 Rail 35 x �5 x 2,3 PR4 Rail 35 x �5 x �,5 PR5 Other end stops, rails and accessories : see section on accessories.
FEDAD� 3 mm FEDAD� 3 mm FEDAD� 3 mm SCAD AL2 (�) 2 mm AL3 (�) 3 mm DCJ FC2 2 mm FC4 4 mm BJM6 32 A 2 BJM6 32 A 3 BJM6 32 A 4 BJM6 32 A 5 BJM6 32 A �0 BJMI6 32 A 2 BJMI6 32 A 3 BJMI6 32 A 4 BJMI6 32 A 5 BJMI6 32 A �0 BJS6 32 A 20 EV6 BJE6.2 32 A 2 BJE6.3 32 A 3 BJE6.4 32 A 4 BJE6.5 32 A 5 BJE6.6 32 A 6 BJE6.7 32 A 7 BJE6.8 32 A 8 BJE6.9 32 A 9 BJE6.�0 32 A �0 BJB BJADO6.2 �7,5 A 2 BJADO6.3 �7,5 A 3 BJADO6.4 �7,5 A 4 BJADO6.5 �7,5 A 5 BJADO6.�0 �7,5 A �0 BJADO6.20 �7,5 A 20 BJP6 35 A BJA6 32 A �0 BJDP� (2) 50 A 6 <-> �6BJDP3 (2) 70 A 6 <-> �2BJDP4 (2) 50 A 6 <->EL6 35 A PC6 35 A 2 PC6 35 A 3 PC6 35 A 4 PC6 35 A �0 EIP CBM5 0,5 mm CBM8 0,8 mm EP6 4 VSP6 AD2,5 24 A OUMAD OUPAD OUTAD OUTA EXAD2 CEADO.6 CEADOE
1 End section grey blue yellow 2 Separator grey 3 Test socket 4 Test device 5 Test plug
6 Assembled jumper bar (without IP20 protection) 7 Assembled jumper bar (with IP20 protection) 8 Jumper bar not assembled Post + screw + washer 9 Screwless jumper bar orange IP20
10 Jumper bar 11 Screwless jumper bar to be inserted into ADO jaw orange IP20
12 Pivoting jumper bar 13 Jumper bar for alternated jumping 14 Universal jumper bar 15 Connector plate 16 Comb type jumper bar Insulating tip 17 Shield connector
18 Protection label Screw for protection label 19 IDC jumper 20 Hand tool kit 21 Semi-automatic tool 22 Pneumatic tool kit 23 Replacement head kit 24 Extraction tool kit 25 Test connector
R See section on markers marking method
Low Voltage Products & Systems 9ABB Inc. • 888-385-�22� • www.abb-control.com LV009 [�SXU�60009C0202] - June 2007
Part numbersPart numbersPart numbers Part numbersPart numbers Variousapplications
Spacing6mm+0,05.238"
D 4/6.ADO with partition
D 4/6.ADO.� equipped with DIA. 2,5 mm flexible test socket for connector - (2)
Spacing6mm+0,05.238"
Spacing6mm+0,05.238"
Spacing6mm+0,05.238"
Spacing6mm+0,05.238"
D 4/6.ADO.� equipped with DIA. 2 mm test socket for test
D 4/6.ADO.� equipped with DIA. 4 mm test socket for test
D 4/6.ADO equipped with DIA. 2 mm test socket for test side screw.
(�) A circuit separator SCAD and 500 V (IEC) rated voltage are required with these accessories.(2) See column on right: "Various applications". (3) Use of these accessories requires the user to cut out the partition.
FEDAD� 3 mm FEDAD� 3 mm FEDAD� 3 mm SCAD AL2 (�) 2 mm AL3 (�) 3 mm AL4 (�) 4 mm DCO FC2 2 mm FC4 4 mm BJM8 4� A 2 BJM8 4� A 3 BJM8 4� A 4 BJM8 4� A 5 BJM8 4� A �0 BJMI8 4� A 2 BJMI8 4� A 3 BJMI8 4� A 4 BJMI8 4� A 5 BJMI8 4� A �0 BJS8 4� A 20 EV6 BJE8.2 32 A 2 BJE8.3 32 A 3 BJE8.4 32 A 4 BJE8.5 32 A 5 BJE8.6 32 A 6 BJE8.7 32 A 7 BJE8.8 32 A 8 BJE8.9 32 A 9 BJE8.�0 32 A �0 BJB BJP8 50 A BJDP� (2) 50 A spa.8 <-> spa.�6 BJDP3 (2) 70 A spa.8 <-> spa.�2 BJDP5 (2) 50 A spa.8 <-> spa.�0 EL6 35 A PC8 50 A 2 PC8 50 A 3 PC8 50 A 4 PC8 50 A �0 EP6 3 EP8 4 VSP6 AD2,5 24 A OUMAD OUPAD OUTAD OUTA EXAD2 CEADO.8 CEADOE
1 End section grey blue yellow 2 Separator grey 3 Test socket 4 Test device 5 Test plug
6 Assembled jumper bar (without IP20 protection) 7 Assembled jumper bar (with IP20 protection) 8 Jumper bar not assembled Post + screw + washer 9 Screwless jumper bar orange IP20
10 Jumper bar 11 Pivoting jumper bar 12 Universal jumper bar 13 Connector plate 14 Comb type jumper bar 15 Protection label
Screw for protection label 16 IDC jumper 17 Hand tool kit 18 Semi-automatic tool 19 Pneumatic tool kit 20 Replacement head kit 21 Extraction tool kit 22 Test connector
(�) A separator SC and 500 V (IEC) rated voltage are required with these accessories(2) See column : "Various applications"
Standard block 8 mm. For multiple wire connections, the two wires need to be of the same gauge and nature (solid or stranded). Terminal block body material is UL 94 V0.
* Black marking for wire size � - 2,5 mm² (�6 - �4 AWG)
Grey
Notes
th. th. th. DIA. DIA. DIA. orange DIA. DIA. poles poles poles poles poles poles poles poles poles poles poles poles poles poles poles poles poles poles poles poles
End stop th. 9 mm BADL V0 End stop th. �0 mm BAM2 V2 End stop th. �0 mm BAM2V0 V0 Rail 35 x 7,5 x � PR3.Z2 Rail 35 x �5 x 2,3 PR4 Rail 35 x �5 x �,5 PR5 Other end stops, rails and accessories : see section on accessories.
FEDAD� 3 mm FEDAD� 3 mm SCAD AL2 (�) 2 mm AL3 (�) 3 mm AL4 (�) 4 mm DCO FC2 (3) 2 mm FC4 (3) 4 mm BJM8 (�) 4� A 2 BJM8 (�) 4� A 3 BJM8 (�) 4� A 4 BJM8 (�) 4� A 5 BJM8 (�) 4� A �0 BJMI8 (�) 4� A 2 BJMI8 (�) 4� A 3 BJMI8 (�) 4� A 4 BJMI8 (�) 4� A 5 BJMI8 (�) 4� A �0 BJS8 4� A 20 EV6 BJE8.2 4� A 2 BJE8.3 4� A 3 BJE8.4 4� A 4 BJE8.5 4� A 5 BJE8.6 4� A 6 BJE8.7 4� A 7 BJE8.8 4� A 8 BJE8.9 4� A 9 BJE8.�0 4� A �0 BJB BJP8 (�)(4) 50 A BJDP� (�)(2) 50 A 8 <-> �6 BJDP3 (�)(2) 70 A 8 <-> �2 BJDP5 (�)(2) 50 A 8 <-> �0 EL6 (4) 35 A PC8 50 A 2 PC8 50 A 3 PC8 50 A 4 PC8 50 A �0 EP6 3 EP8 4 VSP6 AD2,5 24 A OUMAD OUPAD OUTA EXAD2
1 End section grey blue 2 Separator grey 3 Test socket 4 Test device 5 Test plug
6 Assembled jumper bar (without IP20 protection) 7 Assembled jumper bar (with IP20 protection) 8 Jumper bar not assembled Post + screw + washer 9 Screwless jumper bar orange IP20
10 Jumper bar 11 Pivoting jumper bar 12 Universal jumper bar 13 Connector plate 14 Comb type jumper bar 15 Protection label
Screw for protection label 16 IDC jumper 17 Hand tool kit 18 Semi-automatic tool 19 Replacement head kit 20 Extraction tool kit
(2) BJDP1is used for the interconnection with terminal block series "M" : spacing �6 mm. BJDP3is used for the interconnection with terminal block series "M" : spacing �2 mm. BJDP5is used for the interconnection with terminal block series "M" : spacing �0 mm.
(�) A circuit separator SC is required and 500 V (IEC) rated voltage with these accessories. (3) Forbidden under explosive atmosphere EEX usage. (4) Only certified for "i" security.
NotesStandard 8 mm block for connection of only one solid or stranded 4 mm² wire.
* White marking for wire size 4 mm² (�2 AWG)
th. th.
DIA. DIA. DIA. Orange DIA. DIA. poles poles poles poles poles poles poles poles poles poles poles poles poles poles poles poles poles poles poles poles
spa. spa. spa. spa. spa. spa. poles poles poles poles blocks blocks
End stop th. 9 mm BADL V0 End stop th. �0 mm BAM2 V2 End stop th. �0 mm BAM2V0 V0 Rail 35 x 7,5 x � PR3.Z2 Rail 35 x �5 x 2,3 PR4 Rail 35 x �5 x �,5 PR5 Other end stops, rails and accessories : see section on accessories.
FED2AD� V0 5 mmSCAD AL2 (�) 2 mm AL3 (�) 3 mm DCJ FC2 2 mm BJM6 (�) 32 A 2 BJM6 (�) 32 A 3 BJM6 (�) 32 A 4 BJM6 (�) 32 A 5 BJM6 (�) 32 A �0 BJMI6 (�) 32 A 2 BJMI6 (�) 32 A 3 BJMI6 (�) 32 A 4 BJMI6 (�) 32 A 5 BJMI6 (�) 32 A �0 BJS6 (�) 32 A 20 EV6 BJE6.2 32 A 2 BJE6.3 32 A 3 BJE6.4 32 A 4 BJE6.5 32 A 5 BJE6.6 32 A 6 BJE6.7 32 A 7 BJE6.8 32 A 8 BJE6.9 32 A 9 BJE6.�0 32 A �0 BJB BJADO6.2 �7,5 A 2 BJADO6.3 �7,5 A 3 BJADO6.4 �7,5 A 4 BJADO6.5 �7,5 A 5 BJADO6.�0 �7,5 A �0 BJADO6.20 �7,5 A 20 BJP6 (�) 35 A BJA6 (�) 32 A �0 EL6 35 A PC6 35 A 2 PC6 35 A 3 PC6 35 A 4 PC6 35 A �0 EIP ITVE CBD2S EP6 4 VSP6 AD2,5 24 A OUMAD OUPAD OUTAD OUTA EXAD2CEADO.6 CEADOE
Standard block 6 mm. For multiple wires connections, the two wires need to be of the same gauge and nature (solid or stranded). Terminal block body material is UL 94 V0.
The use of some accessories may decrease the block's voltage rating. For more information, consult us.
End stop th. �2 mm BADH V2 End stop th. 9,� mm BAMH V2 End stop th. 9,� mm BAMHV0 V0 Rail 35 x 7,5 x � PR3.Z2 Rail 35 x �5 x 2,3 PR4 Rail 35 x �5 x �,5 PR5 Other end stops, rails and accessories : see section on accessories.
1 End section grey 2 Separator grey 3 Test socket 4 Test device 5 Test plug 6 Assembled jumper bar (without IP20 protection) 7 Assembled jumper bar (with IP20 protection) 8 Jumper bar not assembled Post + screw + washer 9 Screwless jumper bar orange IP20
10 Jumper bar 11 Screwless jumper bar to be inserted into ADO jaw orange IP20
12 Pivoting jumper bar 13 Jumper bar for alternated jumping 14 Connector plate 15 Comb type jumper bar
Insulating tip 16 Vertical jumper bar 17 Shield connector 18 Protection label Screw for protection label 19 IDC jumper 20 Hand tool kit 21 Semi-automatic tool 22 Pneumatic tool kit 23 Replacement head kit 24 Extraction tool kit 25 Test connector
R See section on markers marking method
�4 Low Voltage Products & Systems
LV009 [�SXU�60009C0202] - June 2007 ABB Inc. • 888-385-�22� • www.abb-control.com
3
5
4
6
23
2
�
7
�7
�6
�8
�5
�9
20
�2
�3
�4
FED2AD� V0 th. 5,0 mm AL2 (�) DIA. 2,0 mm AL3 (�) DIA. 3,0 mm DCJ yellow FC2 DIA. 2,0 mm BJM6 (�) 32 A 2 poles BJM6 (�) 32 A 3 poles BJM6 (�) 32 A 4 poles BJM6 (�) 32 A 5 poles BJM6 (�) 32 A �0 poles BJMI6 (�) 32 A 2 poles BJMI6 (�) 32 A 3 poles BJMI6 (�) 32 A 4 poles BJMI6 (�) 32 A 5 poles BJMI6 (�) 32 A �0 poles BJS6 (�) 32 A 20 poles EV6 BJE6.2 32 A 2 poles BJE6.3 32 A 3 poles BJE6.4 32 A 4 poles BJE6.5 32 A 5 poles BJE6.6 32 A 6 poles BJE6.7 32 A 7 poles BJE6.8 32 A 8 poles BJE6.9 32 A 9 poles BJE6.�0 32 A �0 poles BJB BJADO6.2 �7,5 A 2 poles BJADO6.3 �7,5 A 3 poles BJADO6.4 �7,5 A 4 poles BJADO6.5 �7,5 A 5 poles BJADO6.�0 �7,5 A �0 poles BJADO6.20 �7,5 A 20 poles BJP6 (�) 35 A BJA6 (�) 32 A �0 poles EL6 35 A PC6 35 A 2 poles PC6 35 A 3 poles PC6 35 A 4 poles PC6 35 A �0 poles EIP ITVE CBD2S EP6 4 blocks VSP6 AD2,5 24 A OUMAD OUPAD OUTAD OUTA EXAD2CEADO.6CEADOE
22
2�
��
�0
D4/6.D2.ADO.1
9,5 mm 4 mm 0,5-0,8 Nm IP 20 .37" .�57" 4.4-7.� lb.in. NEMA �
Standard block 6 mm double deck. For multiple wires connections, the two wires need to be of the same gauge and nature (solid or stranded). Terminal block body material is UL 94 V0.
Some accessories can decrease the block's voltage rating. Consult us for more information.
1 End section grey 2 Test socket 3 Test device 4 Test plug 5 Assembled jumper bar (without IP20 protection) 6 Assembled jumper bar (with IP20 protection) 7 Jumper bar not assembled Post + screw + washer 8 Screwless jumper bar orange IP20
9 Jumper bar 10 Screwless jumper bar to be inserted into ADO jaw orange IP20
11 Pivoting jumper bar 12 Jumper bar for alternated jumping 13 Connector plate 14 Comb type jumper bar
Insulating tip 15 Vertical jumper bar 16 Shield connector 17 Protection label Screw for protection label 18 IDC jumper 19 Hand tool kit 20 Semi-automatic tool 21 Pneumatic tool kit 22 Replacement head kit 23 Extraction tool kit 24 Test connector
End stop th. �2 mm BADH V2 End stop th. 9,� mm BAMH V2 End stop th. 9,� mm BAMHV0 V0 Rail 35 x 7,5 x � PR3.Z2 Rail 35 x �5 x 2,3 PR4 Rail 35 x �5 x �,5 PR5 Other end stops, rails and accessories : see section on accessories.
Low Voltage Products & Systems �5ABB Inc. • 888-385-�22� • www.abb-control.com LV009 [�SXU�60009C0202] - June 2007
D6/8.D2.ADO
D6/8.D2.N.ADO
0,2-�0 mm² 0,22-6 mm² �-2,5 mm² �-2,5 mm²
800 V 8 kV 3
24 A
2,5 mm²
R
20
2
4
3
5
�9
�
6
7
�3�4
�2
�5
�6
�0
��
�2 RTM7 �7 RC8�0 5 RCAL85
ADO
�8
�7
�2 mm 4 - 4,5mm 0,8 - � Nm IP 20 .47" .�57" - .�77" 7.� - 8.9 lb.in.
2�
FED2AD� V0 5 mm AL2 (�) 2 mm AL3 (�) 3 mm AL4 (�) 4 mm DCO FC2 (2) 2 mm FC4 (2) 4 mm BJM8 (�) 4� A 2 poles BJM8 (�) 4� A 3 poles BJM8 (�) 4� A 4 poles BJM8 (�) 4� A 5 poles BJM8 (�) 4� A �0 poles BJMI8 (�) 4� A 2 poles BJMI8 (�) 4� A 3 poles BJMI8 (�) 4� A 4 poles BJMI8 (�) 4� A 5 poles BJMI8 (�) 4� A �0 poles BJS8 4� A 20 poles EV6 BJE8.2 4� A 2 poles BJE8.3 4� A 3 poles BJE8.4 4� A 4 poles BJE8.5 4� A 5 poles BJE8.6 4� A 6 poles BJE8.7 4� A 7 poles BJE8.8 4� A 8 poles BJE8.9 4� A 9 poles BJE8.�0 4� A �0 poles BJB BJP8 (�)(3) 50 A EL6 (3) 35 A PC8 50 A 2 poles PC8 50 A 3 poles PC8 50 A 4 poles PC8 50 A �0 poles EIP ITVE EP6 3 poles EP8 4 poles VSP6 AD2,5 24 A OUMAD OUPAD OUTAD OUTA BP8.A4 CEADO.8 CEADOE
1 End section grey 2 Test socket 3 Test device 4 Test plug 5 Assembled jumper bar (without IP20 protection) 6 Assembled jumper bar (with IP20 protection) 7 Jumper bar not assembled Post + screw + washer 8 Screwless jumper bar orange IP20
9 Jumper bar 10 Pivoting jumper bar 11 Connector plate 12 Comb type jumper bar
Insulating tip 13 Vertical jumper bar 14 Protection label Screw for protection label 15 IDC jumper 16 Hand tool kit 17 Semi-automatic tool 18 Pneumatic tool 19 Replacement head kit 20 Bridging plug 21 Test connector
R See section on markers marking method
(�) SC obligatory rated voltage with these accessories. (2) Forbidden under explosive atmosphere EEX usage. (3) Only certified for "i" security.
Standard block 8 mm. For multiple wires connections, the two wires need to be of the same gauge and nature (solid or stranded). Terminal block body material is UL 94 V0.
The use of some accessories may decrease the block's voltage rating. For more information, consult us.
End stop th. �2 mm BADH V2 End stop th. 9,� mm BAMH V2 End stop th. 9,� mm BAMHV0 V0 Rail 35 x 7,5 x � PR3.Z2 Rail 35 x �5 x 2,3 PR4 Rail 35 x �5 x �,5 PR5 Other end stops, rails and accessories : see section on accessories.
LV009 [�SXU�60009C0202] - June 2007 ABB Inc. • 888-385-�22� • www.abb-control.com
IEC NFC DIN
UL CSA
D6/8.D2.ADO.1
0,2-�0 mm² 0,22-6 mm² �-2,5 mm² �-2,5 mm²
800 V 8 kV 3
24 A
2,5 mm²
R
20
2
4
3
5
�9
�
6
7
�3�4
�2
�5
�6
�0
��
�2 RTM7 �7 RC8�0 5 RCAL85
ADO
�8
�7
�2 mm 4 - 4,5mm 0,8 - � Nm IP 20 .47" .�57" - .�77" 7.� - 8.9 lb.in.
2�
FED2AD� V0 5 mm AL2 (�) 2 mm AL3 (�) 3 mm AL4 (�) 4 mm DCO FC2 (2) 2 mm FC4 (2) 4 mm BJM8 (�) 4� A 2 polesBJM8 (�) 4� A 3 poles BJM8 (�) 4� A 4 poles BJM8 (�) 4� A 5 poles BJM8 (�) 4� A �0 poles BJMI8 (�) 4� A 2 poles BJMI8 (�) 4� A 3 poles BJMI8 (�) 4� A 4 poles BJMI8 (�) 4� A 5 poles BJMI8 (�) 4� A �0 poles BJS8 4� A 20 poles EV6 BJE8.2 4� A 2 poles BJE8.3 4� A 3 poles BJE8.4 4� A 4 poles BJE8.5 4� A 5 poles BJE8.6 4� A 6 poles BJE8.7 4� A 7 poles BJE8.8 4� A 8 poles BJE8.9 4� A 9 poles BJE8.�0 4� A �0 poles BJB BJP8 (�)(3) 50 A EL6 (3) 35 A PC8 50 A 2 poles PC8 50 A 3 poles PC8 50 A 4 poles PC8 50 A �0 poles EIP ITVE EP6 3 poles EP8 4 poles VSP6 AD2,5 24 A OUMAD OUPAD OUTAD OUTA BP8.A4 CEADO.8 CEADOE
End stop th. �2 mm BADH V2 End stop th. 9,� mm BAMH V2 End stop th. 9,� mm BAMHV0 V0 Rail 35 x 7,5 x � PR3.Z2 Rail 35 x �5 x 2,3 PR4 Rail 35 x �5 x �,5 PR5 Other end stops, rails and accessories : see section on accessories.
1 End section grey 2 Test socket 3 Test device 4 Test plug 5 Assembled jumper bar (without IP20 protection) 6 Assembled jumper bar (with IP20 protection) 7 Jumper bar not assembled Post + screw + washer 8 Screwless jumper bar orange IP20
9 Jumper bar 10 Pivoting jumper bar 11 Connector plate 12 Comb type jumper bar
Insulating tip 13 Vertical jumper bar 14 Protection label Screw for protection label 15 IDC jumper 16 Hand tool kit 17 Semi-automatic tool 18 Pneumatic tool 19 Replacement head kit 20 Bridging plug 21 Test connector
R See section on markers marking method
(�) SC obligatory rated voltage with these accessories. (2) Forbidden under explosive atmosphere EEX usage. (3) Only certified for "i" security.
Standard block 8 mm. For multiple wires connections, the two wires need to be of the same gauge and nature (solid or stranded). Terminal block body material is UL 94 V0.
The use of some accessories may decrease the block's voltage rating. For more information, consult us.
Standard ADO/Screw clamp terminal blocks with 6 and 8 mm spacing are compatible with Screw clamp/Screw clamp switch terminal blocks for neutral circuits.
Wire connection and removal is possible with busbar in its place.
9,5 mm 3,5 mm 0,4-0,6 Nm IP 20 .37" .�37" 3.5-5.3 lb.in NEMA �
FEDAD4 2 mm FEDAD4 2 mm FC2 2 mm PC5 30 A 2 PC5 30 A �0 EIP CBD� 0,8 mm OUMAD OUPAD OUTAD OUTA EXAD2 BJADO5.2 �3,5 A 2 BJADO5.3 �3,5 A 3 BJADO5.4 �3,5 A 4 BJADO5.5 �3,5 A 5 BJADO5.�0 �3,5 A �0 BJADO5.20 �3,5 A 20 CEADO.5 CEADOE
FEDAD4 2 mm FEDAD4 2 mm FC2 2 mm PC5 30 A 2 PC5 30 A �0 EIP CBD� 0,8 mm OUMAD OUPAD OUTAD OUTA EXAD2 BJADO5.2 �3,5 A 2 BJADO5.3 �3,5 A 3 BJADO5.4 �3,5 A 4 BJADO5.5 �3,5 A 5 BJADO5.�0 �3,5 A �0 BJADO5.20 �3,5 A 20 CEADO.5 CEADOE
5 RC55 �� RC5�0
�
2
6
5
8
3
4
5 RC55 �� RC5�0
7
9
IEC UL/CSA NFC DIN
IEC UL/CSA NFC DIN
�0
��
R
D2,5/5.SN.ADO D2,5/5.SN.ADO
D2,5/5.SNT2.ADO D2,5/5.SNT2.ADO D2,5/5.SNT23.ADO
Solid wire Stranded wire
Solid wire Stranded wire
1 End section grey orange 2 Test plug 3 Comb-type jumper Insulating tip 4 Shield connector 5 Hand tool kit 6 Semi-automatic tool 7 Pneumatic tool kit 8 Replacement head kit 9 Extraction tool kit 10 Screwless jumper bar to be inserted into ADO jaw orange IP20
End stop th. 9 mm BADL V0 End stop th. �0 mm BAM2 V2 End stop th. �0 mm BAM2V0 V0 Rail 35 x 7,5 x � PR3.Z2 Rail 35 x �5 x 2,3 PR4 Rail 35 x �5 x �,5 PR5 Other end stops, rails and accessories : see section on accessories.
With DIA. 2 mm screw test socket for test on screw side.Grey Orange With DIA. 2.3 mm screw test socket for test on screw side.Grey
Grey Orange
th. DIA. poles th.
poles poles poles poles poles poles
th. DIA. poles
th.
poles poles poles poles poles poles
Standard block 6 mm. For multiple wire connections, the two wires need to be of the same gauge and nature (solid or stranded). Terminal block body material is UL 94 V0.
All switch terminal blocks offer a test point (DIA. 2 mm or DIA. 2.3 mm on block D 4/6.SNT23.ADO ) on the ADO side of the block.
End stop th. 9 mm BADL V0 End stop th. 10 mm BAM2 V2 End stop th. 10 mm BAM2V0 V0 Rail 35 x 7,5 x 1 PR3.Z2 Rail 35 x 15 x 2,3 PR4 Rail 35 x 15 x 1,5 PR5 Other end stops, rails and accessories : see section on accessories.
9,5 mm 4 mm 0,5-0,8 Nm IP 20 .37" .16" 4.4-7.1 lb.in NEMA 1
FEDAD4 2 mm FC2 2 mm PC61 35 A 10 AD2,5 24 A CBD1 0,8 mm OUMAD OUPAD OUTAD OUTA EXAD2 BJADO6.2 17,5 A 2 BJADO6.3 17,5 A 3 BJADO6.4 17,5 A 4 BJADO6.5 17,5 A 5 BJADO6.10 17,5 A 10 BJADO6.20 17,5 A 20 CEADO.6 CEADOE
11 RC610 5 RC65
ADO ADO
R11 RC610 5 RC65
1
2
7
6
9
3
4
5
8
10
11
12
IECUL CSA NFC DIN
D4/6.SNT2.ADO D4/6.SNT2.ADO
D4/6.SNT23.ADO
IECUL CSA NFC DIN
1 End section grey 2 Test plug 3 Comb-type jumper bar 4 IDC jumper 5 Shield connector 6 Hand tool kit 7 Semi-automatic tool 8 Pneumatic tool kit 9 Replacement head kit 10 Extraction head kit 11 Screwless jumper bar to be inserted into ADO jaw orange IP20
12 Test connector
R See section on markers Marking method
D4/6.SN.ADO D4/6.SN.ADO 0199107.24 0199108.05
FEDAD4 2 mm FC2 2 mm PC61 35 A 10 AD2,5 24 A CBD1 0,8 mm OUMAD OUPAD OUTAD OUTA EXAD2 BJADO6.2 17,5 A 2 BJADO6.3 17,5 A 3 BJADO6.4 17,5 A 4 BJADO6.5 17,5 A 5 BJADO6.10 17,5 A 10 BJADO6.20 17,5 A 20 CEADO.6 CEADOE
Standard bloc 8 mm. For multiple wires connections, the two wires need to be of the same gauge and nature (solid or stranded). Terminal block body material is UL 94 V0.
All switch terminal blocks offer a test point (DIA. 2 mm or DIA 2.3 mm on block D 4/6.SNT23.ADO ) on the ADO side of the block.
* Black marking for wire size 1 - 2,5 mm² (16 - 14 AWG)
GreyOrange
th. DIA. poles
With DIA 2 mm screw test socket for test on screw side.Grey Orange With DIA 2.3 mm screw test socket for test on screw side.Grey
th. DIA. poles
1 End section grey 2 Test plug 3 Comb-type jumper bar 4 IDC jumper 5 Hand tool kit 6 Semi automatic tool 7 Pneumatic tool kit 8 Replacement head kit 9 Extraction tool kit 10 Test connector
End stop th. 9 mm BADL V0 End stop th. 10 mm BAM2 V2 End stop th. 10 mm BAM2V0 V0 Rail 35 x 7,5 x 1 PR3.Z2 Rail 35 x 15 x 2,3 PR4 Rail 35 x 15 x 1,5 PR5 Other end stops, rails and accessories : see section on accessories.
Low Voltage Products & Systems 23ABB Inc. • 888-385-1221 • www.abb-control.com LV009 [1SXU160009C0202] - June 2007
BNF52
BNSV82
BNF652
BNF652D(3)BNF652D1(4)BNF652L(5)
D4/8.S.ADO
BNSV62
D4/6.S.ADO
BNS.D5
D2,5/5.S.ADO
FU520 0,5 A
FU520 1 A
FU520 2 A
FU520 3.15 A
FU520 5 A
FU525 1.6 A
FU525 2 A
FU525 2.5 A
FU525 4 A
FU525 6.3 A
FUPLV 1 A
FUPLV 2 A
FUPLV 5 AFUAUTO 2 A
FUAUTO 3 A
BNC62
BFAUTO
BNCT82
D2,5/5.SFA...ADO
BFSAUTO
FUBS 0,5 A
FUBS 1 A
FUBS 2 A
FUBS 3 A
FUBS 5 A
Typesoffuses
Selectionguidefordifferenttypesofplugs
Typesoffuses
Fuse
pro
tect
ion
func
tio
nS
wit
chin
gf
unc-
tio
n
Plugwithsol-dertagsand
screws(1)
Fuseholderplug
Fuseholder
plug
Short-circuitplug
Fuses5x20mm Fuses5x25mmSolderedfuses
FlatfusesAutomotiveminiaturefuses
Typesofplugs
Automotive miniature fuses (2)
type FUAUTO 2 A to 3 A - 32 V maxi
Soldered fuses
type FUBS- 0,5 to 5 A - 250 V
Flat fuses
type FUPLV- 1 to 5 A - 250 V
Fuses 5 x 20
type FU520- 0,5 to 5 A - 250 V
Fuses 5 x 25
type FU525- 1,6 to 6,3 A - 250 V
Nota : (1) Compatible with electronic components max.diameter or thickness for components : - plug BNSV62 : 4 mm/.157" max. - plug BNSV82 : 6 mm /.236"max. (2) For all fuses, the dissipated load should remain under 0,8 W. (3) with led 24 V AC/DC. (4) with led 48 V AC/DC. (5) avec neon lamp 110-230 V AC/DC.
V0black
without test with test
closed 18,5 .73"Plugopen 29 1.14"
V0black
0196924.03
0196927.06
0196998.16
0196999.17
0196966.15
0196967.16
0196854.15 0295381.26
0008288.15
0008290.13
0008291.00
0008289.16
0008292.01
0167546.22
0167547.23
0167548.04
0167549.05
0167550.02
0174893.16
0174894.17
0174895.10
0174896.11
0174897.12
0008096.20
0008097.21
0008098.02
0179879.14
0179880.02
0196853.14
0299486.24
0196926.05
0299877.03
24 Low Voltage Products & Systems
LV009 [1SXU160009C0202] - June 2007 ABB Inc. • 888-385-1221 • www.abb-control.com
9,5 mm 3,5 mm 0,4-0,6 Nm IP 20 .37" .137" 3.5-5.3 lb.in NEMA 1
FEDAD4 2 mm FEDAD4 2 mm PC5 30 A 2 PC5 30 A 10 EIP
BNS.D5 5 mm EXBN2 FUBS 0,5 A FUBS 1 A FUBS 2 A FUBS 3 A FUBS 5 A
CBD1 0,8 mm OUMAD OUPAD OUTAD OUTA EXAD2 BJADO5.2 13,5 A 2 BJADO5.3 13,5 A 3 BJADO5.4 13,5 A 4 BJADO5.5 13,5 A 5 BJADO5.10 13,5 A 10 BJADO5.20 13,5 A 20 CEADO.5 CEADOE
9,5 mm 4 mm 0,5-0,8 Nm IP 20 .37" .16" 4.4-7.1 lb.in NEMA 1
FEDAD4 2 mm FEDAD4 2 mm
PC61 35 A 10 AD2,5 24 A
EXBN2
BNC62 (2) 6 mm BNSV62 (2) 6 mm BFAUTO V0 BNF652V0 V0 6 mm
BNF652 D (1) V0 6 mm BNF652 D1 (1) V0 6 mm BNF652 L (1) V0 6 mm CBD1 0,8 mm OUMAD OUPAD OUTAD OUTA EXAD2 BJADO6.2 17,5 A 2 BJADO6.3 17,5 A 3 BJADO6.4 17,5 A 4 BJADO6.5 17,5 A 5 BJADO6.10 17,5 A 10 BJADO6.20 17,5 A 20 CEADO.6 CEADOE
Switch connection block 6 mm by polarized plug, deliv-ered separately.
Solid wire Stranded wireADO
5 mm and 6 mm blocks. For multiple wire connections, the two wires need to be of the same gauge and nature (solid or stranded). Terminal block body material is UL 94 V0.
* Black marking for wire size 1 - 2,5 mm² (16 - 14 AWG)
(1) Leakage current with LED 24 V or 48 V : < 1,6 mA and with neon lamp 110 or 230 VAC/DC : < 0,5 mA.(2) See selection guide for dimensions of plugs and type of fuses to use.(3) Terminal block insulating voltage, working voltage according to fuse.
End stop th. 9 mm BADL V0 End stop th. 10 mm BAM2 V2 End stop th. 10 mm BAM2V0 V0 Rail 35 x 7,5 x 1 PR3.Z2 Rail 35 x 15 x 2,3 PR4 Rail 35 x 15 x 1,5 PR5 Other end stops, rails and accessories : see section on accessories.
1 End section grey orange 2 Comb-type jumper bar 3 IDC jumper 4 Short-circuit plug (1) 5 Fuse holder plug (for soldered fuses or flat fuses) (1) 6 Fuse holder plug (for 5 x 20 or 5 x 25 fuses) (1) 7 Plug extractor 8 Hand tool kit 9 Semi-automatic tool 10 Pneumatic tool kit 11 Replacement head kit 12 Extraction head kit 13 Test connector
R See section on markers Marking method
(1) See selection guide for dimensions of plugs and type of fuses to use.(2) Terminal block insulating voltage, working voltage according to fuse.
Switch connection block 8 mm by polarized plug, deliv-ered separately.
8 mm blocks. For multiple wire connections, the two wires need to be of the same gauge and nature (solid or stranded). Terminal block body material is UL 94 V0.
* Black marking for wire size 1 - 2,5 mm² (16 - 14 AWG)
End stop th. 9 mm BADL V0 End stop th. 10 mm BAM2 V2 End stop th. 10 mm BAM2V0 V0 Rail 35 x 7,5 x 1 PR3.Z2 Rail 35 x 15 x 2,3 PR4 Rail 35 x 15 x 1,5 PR5 Other end stops, rails and accessories : see section on accessories.
9,5 mm 3,5 mm 0,4-0,6 Nm IP 20 .37" .137" 3.5-5.3 lb.in NEMA 1
FEDAD4 2 mm FEDAD4 2 mm FC2 2 mm PC5 2 PC5 10 BF5AUTO FUAUTO 2 A FUAUTO 3 A CBD1 0,8 mm OUMAD OUPAD OUTAD OUTA EXAD2 BJADO5.2 13,5 A 2 BJADO5.3 13,5 A 3 BJADO5.4 13,5 A 4 BJADO5.5 13,5 A 5 BJADO5.10 13,5 A 10 BJADO5.20 13,5 A 20 CEADO.5 CEADOE
FEDAD4 2 mm FEDAD4 2 mm FC2 2 mm PC5 2 PC5 10 BF5AUTO FUAUTO 2 A FUAUTO 3 A CBD1 0,8 mm OUMAD OUPAD OUTAD OUTA EXAD2 BJADO5.2 13,5 A 2 BJADO5.3 13,5 A 3 BJADO5.4 13,5 A 4 BJADO5.5 13,5 A 5 BJADO5.10 13,5 A 10 BJADO5.20 13,5 A 20 CEADO.5 CEADOE
5 RC55 11 RC510
R5 RC55 11 RC510
1
2
8
7
10
3
4
6
5
9
11
IEC UL/CSA NFC DIN
IEC UL/CSA NFC DIN
12
13
D2,5/5.SFA.ADO D2,5/5.SFA.ADO
D2,5/5.SFAT2.ADO D2,5/5.SFAT23.ADO
Solid wire Stranded wire
Solid wire Stranded wire
1 End section grey orange 2 Test plug 3 Comb-type jumper
4 Fuse-holder plug black 5 Mini Fuse - 32 V max.
6 Shield connector 7 Hand tool kit 8 Semi-automatic tool 9 Pneumatic tool kit 10 Replacement head kit 11 Extraction tool kit 12 Screwless jumper bar to be inserted into ADO jaw orange IP20
(1) Terminal block insulating voltage. Working voltage according to fuse (32 V max.).
0399236.04 0399237.05
0399238.16 0399239.17
th. 0199 352.00 th. 0199 353.01 DIA. 0007 865.26 poles 0113 542.10 poles 0113 544.12 0299 877.03 0179 879.14 0179 880.02 th. 0179 634.06 0179 466.06 0178 944.04 0205 710.11 0205 284.03 0205 721.00 poles 0205 955.03 poles 0205 956.04 poles 0205 957.05 poles 0205 958.16 poles 0205 963.03 poles 0205 973.05 0399 345.11 0399 341.15
th. 0199 352.00 th. 0199 353.01 DIA. 0007 865.26 poles 0113 542.10 poles 0113 544.12 0299 877.03 0179 879.14 0179 880.02 0179 634.06 0179 466.06 0178 944.04 0205 710.11 0205 284.03 0205 721.00 poles 0205 955.03 poles 0205 956.04 poles 0205 957.05 poles 0205 958.16 poles 0205 963.03 poles 0205 973.05 0399 345.11 0399 341.15
End stop th. 9 mm BADL V0 End stop th. 10 mm BAM2 V2 End stop th. 10 mm BAM2V0 V0 Rail 35 x 7,5 x 1 PR3.Z2 Rail 35 x 15 x 2,3 PR4 Rail 35 x 15 x 1,5 PR5 Other end stops, rails and accessories : see section on accessories.
1 End section grey 2 Test plug 3 Comb-type jumper bar 4 IDC jumper 5 Assembly rod
6 Assembly ring 7 5x20 fuses - 250 V
5x25 fuses - 250 V
8 Hand tool kit 9 Semi automatic kit 10 Pneumatic tool kit 11 Replacement head kit 12 Extraction tool kit 13 Test connector
R See section on marking Marking method
Standard block 8 mm. For multiple wires connections, the two wires need to be of the same gauge and nature (solid or stranded). Terminal block body material is UL 94 V0.
All switch terminal blocks offer a test point (DIA. 2 mm or DIA 2.3 mm on block D 4/6.SNT23.ADO ) on the ADO side of the block.
Grey Orange
With DIA. 2 mm screw test socket for test on screw side.Grey
(1) Terminal block insulation voltage. Working voltage according to fuse.
End stop th. 9 mm BADL V0 End stop th. 10 mm BAM2 V2 End stop th. 10 mm BAM2V0 V0 Rail 35 x 7,5 x 1 PR3.Z2 Rail 35 x 15 x 2,3 PR4 Rail 35 x 15 x 1,5 PR5 Other end stops, rails and accessories : see section on accessories.
LV009 [1SXU160009C0202] - June 2007 ABB Inc. • 888-385-1221 • www.abb-control.com
D4/8.SF...I.ADO
9,5 mm 4 mm 0,5-0,8 Nm IP 20 .37" .16" 4.4-7.1 lb.in NEMA 1
FEDAD10 th. 1,5 mm FC2 DIA. 2 mm PC81 35 A 10 poles AD2,5 24 A TGA8 2 poles TGA8 3 poles TGA8 4 poles ANT FU520 0,5 A FU520 1 A FU520 2 A FU520 3,15 A FU520 5 A FU525 1,6 A FU525 2 A FU525 2,5 A FU525 4 A FU525 6,3 A OUMAD OUPAD OUTAD OUTA EXAD2 CEADO.8 CEADOE
FEDAD10 th. 1,5 mm FC2 DIA. 2 mm PC81 35 A 10 poles AD2,5 24 A TGA8 2 poles TGA8 3 poles TGA8 4 poles ANT FU520 0,5 A FU520 1 A FU520 2 A FU520 3,15 A FU520 5 A FU525 1,6 A FU525 2 A FU525 2,5 A FU525 4 A FU525 6,3 A OUMAD OUPAD OUTAD OUTA EXAD2 CEADO.8 CEADOE
Standard bloc 8 mm. For multiple wires connections, the two wires need to be of the same gauge and nature (solid or stranded). Terminal block body material is UL 94 V0.
All switch terminal blocks offer a test point (DIA. 2 mm or DIA 2.3 mm on block D 4/6.SNT23.ADO ) on the ADO side of the block.
Grey (1) Grey (2) Grey (3)
Grey (1) Grey (2) Grey (3)
1 End section grey 2 Test plug 3 Comb-type jumper bar 4 IDC jumper 5 Assembly rod
6 Assembly ring 7 5x20 fuses - 250 V
5x25 fuses - 250 V
8 Hand tool kit 9 Semi automatic kit 10 Pneumatic tool kit 11 Replacement head kit 12 Extraction tool kit 13 Test connector
(1) Blown-fuse indicator by 110 V - 230 V neon lamp (leakage current with neon lamp < 0,5 mA (110 V) - < 0,7 mA (230 V)).
(2) Blown-fuse indicator by LED 24 V ( +24V labeled) (leakage current with LED 24 V or 48 V < 4,5 mA).(3) Blown-fuse indicator by LED 48 V ( +48V labeled) (leakage current with LED 24 V or 48 V < 4,5 mA).
End stop th. 9 mm BADL V0 End stop th. 10 mm BAM2 V2 End stop th. 10 mm BAM2V0 V0 Rail 35 x 7,5 x 1 PR3.Z2 Rail 35 x 15 x 2,3 PR4 Rail 35 x 15 x 1,5 PR5 Other end stops, rails and accessories : see section on accessories.
Low Voltage Products & Systems 29ABB Inc. • 888-385-1221 • www.abb-control.com LV009 [1SXU160009C0202] - June 2007
IEC UL CSA NFC DIN
IEC UL CSA NFC DIN
D4/8.SF.I.ADO2
9,5 mm 4 mm 0,5-0,8 Nm IP 20 .37" .16" 4.4-7.1 lb.in NEMA 1
FEDAD10 th. 1,5 mm FC2 V2 DIA. 2 mm PC81 V2 35 A 10 poles AD2,5 V2 24 A TGA8 2 poles TGA8 3 poles TGA8 4 poles ANT FU520 0,5 A FU520 1 A FU520 2 A FU520 3,15 A FU520 5 A FU525 1,6 A FU525 2 A FU525 2,5 A FU525 4 A FU525 6,3 A OUMAD OUPAD OUTAD OUTA EXAD2 CEADO.8 CEADOE
D4/8.SFT2.I.ADO2
D4/8.SFT2.I.ADO2
9,5 mm 4 mm 0,5-0,8 Nm IP 20 .37" .16" 4.4-7.1 lb.in NEMA 1
FEDAD10 th. 1,5 mm FC2 V2 DIA. 2 mm PC81 V2 35 A 10 poles AD2,5 V2 24 A TGA8 2 poles TGA8 3 poles TGA8 4 poles ANT FU520 0,5 A FU520 1 A FU520 2 A FU520 3,15 A FU520 5 A FU525 1,6 A FU525 2 A FU525 2,5 A FU525 4 A FU525 6,3 A OUMAD OUPAD OUTAD OUTA EXAD2 CEADO.8 CEADOE
1 End section grey 2 Test plug 3 Comb-type jumper bar 4 IDC jumper 5 Assembly rod
6 Assembly ring 7 5x20 fuses - 250 V
5x25 fuses - 250 V
8 Hand tool kit 9 Semi automatic kit 10 Pneumatic tool kit 11 Replacement head kit 12 Extraction tool kit 13 Test connector
R See section on marking Marking method
Standard block 8 mm. For multiple wires connections, the two wires need to be of the same gauge and nature (solid or stranded). Terminal block body material is UL 94 V0.
All switch terminal blocks offer a test point (DIA. 2 mm or DIA 2.3 mm on block D 4/6.SNT23.ADO ) on the ADO side of the block.
* - Black marking + 2 notches for wire size 1 - 2,5 mm² (16-14 AWG)
Grey Orange
With DIA. 2 mm screw test socket for test on screw side.Grey
End stop th. 9 mm BADL V0 End stop th. 9,1 mm BAM V2 End stop th. 9,1 mm BAMV0 V0 Rail 35 x 7,5 x 1 PR3.Z2 Rail 35 x 15 x 2,3 PR4 Rail 35 x 15 x 1,5 PR5 Other end stops, rails and accessories : see section on accessories.
(1) Terminal block insulation voltage. Working voltage according to fuse.
LV009 [1SXU160009C0202] - June 2007 ABB Inc. • 888-385-1221 • www.abb-control.com
IEC UL CSA NFC DIN
D4/8.SF...I.ADO2
9,5 mm 4 mm 0,5-0,8 Nm IP 20 .37" .16" 4.4-7.1 lb.in NEMA 1
FEDAD10 th. 1,5 mm FC2 V2 DIA. 2 mm PC81 V2 35 A 10 poles AD2,5 V2 24 A TGA8 2 poles TGA8 3 poles TGA8 4 poles ANT FU520 0,5 A FU520 1 A FU520 2 A FU520 3,15 A FU520 5 A FU525 1,6 A FU525 2 A FU525 2,5 A FU525 4 A FU525 6,3 A OUMAD OUPAD OUTAD OUTA EXAD2 CEADO.8 CEADOE
D4/8.SF...T2.I.ADO2
9,5 mm 4 mm 0,5-0,8 Nm IP 20 .37" .16" 4.4-7.1 lb.in NEMA 1
FEDAD10 th. 1,5 mm FC2 V2 DIA. 2 mm PC81 V2 35 A 10 poles AD2,5 V2 24 A TGA8 2 poles TGA8 3 poles TGA8 4 poles ANT FU520 0,5 A FU520 1 A FU520 2 A FU520 3,15 A FU520 5 A FU525 1,6 A FU525 2 A FU525 2,5 A FU525 4 A FU525 6,3 A OUMAD OUPAD OUTAD OUTA EXAD2 CEADO.8 CEADOE
1 End section grey 2 Test plug 3 Comb-type jumper bar 4 IDC jumper 5 Assembly rod
6 Assembly ring 7 5x20 fuses - 250 V
5x25 fuses - 250 V
8 Hand tool kit 9 Semi automatic kit 10 Pneumatic tool kit 11 Replacement head kit 12 Extraction tool kit 13 Test connector
R See section on marking Marking method
Standard block 8 mm. For multiple wires connections, the two wires need to be of the same gauge and nature (solid or stranded). Terminal block body material is UL 94 V0.
All switch terminal blocks offer a test point (DIA. 2 mm or DIA 2.3 mm on block D 4/6.SNT23.ADO ) on the ADO side of the block.
* - Black marking + 2 notches for wire size 1 - 2,5 mm² (16 - 14 AWG)
Grey (1) Grey (2) Grey (3)
With DIA. 2 mm screw test socket for test on screw side.Grey (1) Grey (2) Grey (3)
(1) Terminal block insulation voltage. Working voltage according to fuse.
center of rail
Clo
sed
grip
Op
en
grip
center of rail
Clo
sed
grip
Op
en
grip
on grip
(1) Blown-fuse indicator by 110 V - 230 V neon lamp (leakage current with neon lamp < 0,5 mA (110 V) - < 0,7 mA (230 V)).(2) Blown-fuse indicator by LED 24 V ( +24V labeled) (leakage current with LED 24 V or 48 V < 4,5 mA).(3) Blown-fuse indicator by LED 48 V ( +48V labeled) (leakage current with LED 24 V or 48 V < 4,5 mA).
End stop th. 9 mm BADL V0 End stop th. 10 mm BAM2 V2 End stop th. 10 mm BAM2V0 V0 Rail 35 x 7,5 x 1 PR3.Z2 Rail 35 x 15 x 2,3 PR4 Rail 35 x 15 x 1,5 PR5 Other end stops, rails and accessories : see section on accessories.
Standard block 8 mm. For multiple wires connections, the two wires need to be of the same gauge and nature (solid or stranded). Terminal block body material is UL 94 V0.
All switch terminal blocks offer a test point (DIA. 2 mm or DIA 2.3 mm on block D 4/6.SNT23.ADO ) on the ADO side of the block.
1 End section grey 2 Test plug 3 Comb-type jumper bar 4 IDC jumper 5 Assembly rod
6 Assembly ring 7 Hand tool kit 8 Semi automatic tool 9 Pneumatic tool kit 10 Replacement head kit 11 Extraction tool kit 12 Test connector
R See section on markers Marking method
Grey body / Blue grip
With DIA. 2 mm screw test socket for test on screw side.Grey body / Blue grip
End stop th. 9 mm BADL V0 End stop th. 10 mm BAM2 V2 End stop th. 10 mm BAM2V0 V0 Rail 35 x 7,5 x 1 PR3.Z2 Rail 35 x 15 x 2,3 PR4 Rail 35 x 15 x 1,5 PR5 Other end stops, rails and accessories : see section on accessories.
Standard block 8 mm. For multiple wires connections, the two wires need to be of the same gauge and nature (solid or stranded). Terminal block body material is UL 94 V0.
All switch terminal blocks offer a test point (DIA. 2 mm or DIA 2.3 mm on block D 4/6.SNT23.ADO ) on the ADO side of the block.
* - Black marking + 2 notches for wire size 1 - 2,5 mm² (16 - 14 AWG)
Grey body / Blue grip
With DIA. 2 mm screw test socket for test on screw side.Grey body / Blue grip
End stop th. 9 mm BADL V0 End stop th. 10 mm BAM2 V2 End stop th. 10 mm BAM2V0 V0 Rail 35 x 7,5 x 1 PR3.Z2 Rail 35 x 15 x 2,3 PR4 Rail 35 x 15 x 1,5 PR5 Other end stops, rails and accessories : see section on accessories.
FEADRS 3 mm AL2 (1) 2 mm AL3 (1) 3 mm AL4 (1) 4 mm FC2 (2) 2 mm FC4 (2) 4 mm BJM8 (1) 41 A 2 BJM8 (1) 41 A 3 BJM8 (1) 41 A 4 BJM8 (1) 41 A 5 BJM8 (1) 41 A 10 BJMI8 (1) 41 A 2 BJMI8 (1) 41 A 3 BJMI8 (1) 41 A 4 BJMI8 (1) 41 A 5 BJMI8 (1) 41 A 10 BJS8 41 A 20 EV6 BJE8.2 41 A 2 BJE8.3 41 A 3 BJE8.4 41 A 4 BJE8.5 41 A 5 BJE8.6 41 A 6 BJE8.7 41 A 7 BJE8.8 41 A 8 BJE8.9 41 A 9 BJE8.10 41 A 10 BJB BJP8 (1)(3) 50 A EL6 (3) 35 A AD2,5 24 A OUMAD OUPAD OUTAD OUTA BP8.A4 EXAD2 CEADO.8 CEADOEADO
The use of some accessories may decrease the block's voltage rating. For more information, consult us.ADO side : permits connection of 2 wires max. of the same gauge and nature.
* Black marking + 2 notches for wire size 1 - 2,5 mm² (16 - 14 AWG)
Screw
1 End section grey 2 Test socket 3 Test plug
4 Assembled jumper bar (without IP20 protection) 5 Assembled jumper bar (with IP20 protection) 6 Jumper bar not assembled Post + screw + washer 7 Screwlessjumperbar orangeIP20
9 Pivoting jumper bar 10 Connector plate 11 IDC jumper 12 Hand tool kit 13 Semi-automatic tool 14 Pneumatic tool kit 15 Replacement head kit 16 Bridging plug 17 Extraction tool kit 18 Test connector
(1) 500 V (IEC) rated voltage with these accessories. (2) Forbidden under explosive atmo-sphere EEX usage. (3) Only certified for "i" security. (4) See "Notes".
center of rail
Screw clamp terminal for bare wire or equipped with bent lug and ADO wire size.
Each screw-clamp holds 2 bentlugs, as above (not supplied), forconnection of wires :0,28 to 1,5 mm² /1 to 2,5 mm² A = 4,45 to 7,45 for size 1
2,9 to 3,2 for size 2
Notes
th. DIA. DIA. DIA. DIA. DIA. poles poles poles poles poles poles poles poles poles poles poles poles poles poles poles poles poles poles poles poles
End stop th. 9 mm BADL V0 End stop th. 10 mm BAM2 V2 End stop th. 10 mm BAM2V0 V0 Rail 35 x 7,5 x 1 PR3.Z2 Rail 35 x 15 x 2,3 PR4 Rail 35 x 15 x 1,5 PR5 Other end stops, rails and accessories : see section on accessories.
LV009 [1SXU160009C0202] - June 2007 ABB Inc. • 888-385-1221 • www.abb-control.com
DIN 3 : DS... ADO DIN 2 : DR... ADO Snap in : DH... ADO
At the end of the terminal blocks assembly : - End section : (same accessory for any type of terminal block assembly) FEAD1 : V/ADO End section to be mounted directly on FEAD2 : ADO/ADO the open part of the terminal block. - End terminal block : DRE... ADO (DIN2) This terminal block has to be mounted at DSE... ADO (DIN3) the end of the terminal blocks assembly : it reduces its size, because it suppresses the insulation rib (- 4 mm). Note : This terminal block cannot be accidentally located anywhere else into the terminal block assembly (without locking holes).
In the terminal blocks assembly :
- Separator : (same accessory for any type of terminal block assembly) FEAD5 : V/ADO Accessory which snaps on the terminal FEAD6 : ADO/ADO blocks, separates and makes visible the different parts of the terminal blocks assembly.
With screw mounting kit : DB... ADO
Panel mounted with snap in mounting foot :Rail mounted DIN 2 and DIN 3 :
MINIBLOCKSASSEMBLYANDACCESSORIES
ADOMINIBLOCKS
A reduced size range Numerous mounting options
A very legible marking
ADO mini blocks use the same marking technique as stan-dard ENTRELEC terminals, located on the top of the block.
Plate
DIN Rail
Low Voltage Products & Systems 35ABB Inc. • 888-385-1221 • www.abb-control.com LV009 [1SXU160009C0202] - June 2007
9,5 mm 3,5 mm 0,4-0,6 Nm IP 20 .37" .137" 3.5-5.3 ib.in NEMA 1
FEAD1 V0 th. 2,5 mm FEAD1 V0 th. 2,5 mm FEAD5 V0 th. 5,0 mm FEAD5 V0 th. 5,0 mm DCB FC2 DIA. 2 mm BJADO5.2 17,5 A 2 poles BJADO5.3 17,5 A 3 poles BJADO5.4 17,5 A 4 poles BJADO5.5 17,5 A 5 poles BJADO5.10 17,5 A 10 poles BJADO5.20 17,5 A 20 poles PC5 30 A 2 poles PC5 30 A 10 poles EIP OUMAD OUPAD OUTAD OUTA EXAD2 CEADO.5 CEADOE
FEAD1 V0 th. 2,5 mm FEAD1 V0 th. 2,5 mm FEAD5 V0 th. 5,0 mm FEAD5 V0 th. 5,0 mm DCJ FC2 DIA. 2 mm BJADO6.2 17,5 A 2 poles BJADO6.3 17,5 A 3 poles BJADO6.4 17,5 A 4 poles BJADO6.5 17,5 A 5 poles BJADO6.10 17,5 A 10 poles BJADO6.20 17,5 A 20 poles PC6 35 A 2 poles PC6 35 A 3 poles PC6 35 A 4 poles PC6 35 A 10 poles EIP OUMAD OUPAD OUTAD OUTA EXAD2 CEADO.6 CEADOE
5 RC65
9,5 mm 4 mm 0,5-0,8 Nm IP 20 .37" .16" 4.4-7.1 ib.in NEMA 1
Standard blocks 6 and 8 mm. For multiple wires connections, the two wires need to be of the same gauge and nature (solid or stranded). Terminal block body material is UL 94 V0.
On top of block
42,3 1.66"
31 1.22"
20,6 .81"
431.
69"
35,5
1.39
".1
97”
5DS (with rib)
center of rail
DSE (without ribonly for T.B
assembly extremity
1 End section grey orange 2 Separator grey orange 3 Test device yellow blue 4 Test plug 5 Screwless jumper bar to be inserted into ADO jaw orange IP20
6 Comb-type jumper bar
Insulating tip 7 Hand tool kit 8 Semi-automatic tool 9 Pneumatic tool kit 10 Replacement head kit 11 Extraction tool kit 12 Test connector
End stop th. 9 mm BADL V0 End stop th. 10 mm BAM2 V2 End stop th. 10 mm BAM2V0 V0 Rail 35 x 7,5 x 1 PR3.Z2 Rail 35 x 15 x 2,3 PR4 Rail 35 x 15 x 1,5 PR5 Other end stops, rails and accessories : see section on accessories.
End stop th. 9 mm BADL V0 End stop th. 10 mm BAM2 V2 End stop th. 10 mm BAM2V0 V0 Rail 35 x 7,5 x 1 PR3.Z2 Rail 35 x 15 x 2,3 PR4 Rail 35 x 15 x 1,5 PR5 Other end stops, rails and accessories : see section on accessories.
FEAD1 V0 2,5 mm FEAD1 V0 2,5 mm FEAD5 V0 5,0 mm FEAD5 V0 5,0 mm DCB FC2 2 mm BJADO5.2 17,5 A 2 BJADO5.3 17,5 A 3 BJADO5.4 17,5 A 4 BJADO5.5 17,5 A 5 BJADO5.10 17,5 A 10 BJADO5.20 17,5 A 20 PC5 30 A 2 PC5 30 A 10 EIP V2 AD2,5 V2 OUMAD OUPAD OUTAD OUTA EXAD2 CEADO.5 CEADOE
FEAD1 V0 2,5 mm FEAD1 V0 2,5 mm FEAD5 V0 5,0 mm FEAD5 V0 5,0 mm DCJ V2 FC2 2 mm BJADO6.2 17,5 A 2 BJADO6.3 17,5 A 3 BJADO6.4 17,5 A 4 BJADO6.5 17,5 A 5 BJADO6.10 17,5 A 10 BJADO6.20 17,5 A 20 PC6 V2 35 A 2 PC6 V2 35 A 3 PC6 V2 35 A 4 PC6 V2 35 A 10 EIP V2 AD2,5 V2 OUMAD OUPAD OUTAD OUTA EXAD2 CEADO.6 CEADOE
1 End section grey orange 2 Separator grey orange 3 Test device blue 4 Test plug 5 Screwless jumper bar
orange IP20
6 Comb-type jumper bar
Insulation tip 7 IDC jumper 8 Hand tool kit 9 Semi automatic tool 10 Pneumatic tool kit 11 Replacement head kit 12 Extraction tool kit 13 Test connector
R See section on markers marking method
Standard blocks 5, 6 and 8 mm. For multiple wires con-nections, the two wires need to be of the same gauge and nature (solid or stranded). Terminal block body mate-rial is UL 94 V0.
End stop th. 6,5 mm BADRL V0 Rail 15 x 5 x 1 PR2 Other end stops, rails and accessories : see section on accessories.
1 End section grey (left+ right) orange 2 Separator grey orange 3 Test device blue 4 Test plug 5 Screwless jumper bar to be inserted into ADO jaw orange IP20
6 Comb-type jumper bar
Insulating tip 7 IDC jumper 8 Hand tool kit 9 Semi automatic tool 10 Pneumatic tool kit 11 Replacement head kit 12 Extraction tool kit 13 Test connector
R See section on markers marking method
Standard blocks 5, 6 and 8 mm. For multiple wires con-nections, the two wires need to be of the same gauge and nature (solid or stranded). Terminal block body mate-rial is UL 94 V0.
For drilling patterns see page: assembly and accessories
9,5 mm 3,5 mm 0,4 - 0,6 Nm IP 20 .374" .137" 3.5-5.3 ib.in NEMA 1
DH2,5/5.ADO
FEAD1 V0 th. 2,5 mm FEAD1 V0 th. 2,5 mm FEAD5 V0 th. 5,0 mm FEAD5 V0 th. 5,0 mm DCB V2 FC2 DIA. 2 mm BJADO5.2 17,5 A 2 poles BJADO5.3 17,5 A 3 poles BJADO5.4 17,5 A 4 poles BJADO5.5 17,5 A 5 poles BJADO5.10 17,5 A 10 poles BJADO5.20 17,5 A 20 poles PC5 30 A 2 poles PC5 30 A 10 poles EIP V2 AD2,5 V2 24 A OUMAD OUPAD OUTAD OUTA EXAD2 CEADO.5 CEADOE
ADO ADO
5 RC55
31 1.22"
281.
10"
5
.197
”
9,5 mm 4 mm 0,5 - 0,8 Nm IP 20 .374" .157" 4.4-7.1 ib.in NEMA 1
DH4/6.ADO
FEAD1 V0 th. 2,5 mm FEAD1 V0 th. 2,5 mm FEAD5 V0 th. 5,0 mm FEAD5 V0 th. 5,0 mm DCJ V2 FC2 DIA. 2 mm BJADO6.2 17,5 A 2 poles BJADO6.3 17,5 A 3 poles BJADO6.4 17,5 A 4 poles BJADO6.5 17,5 A 5 poles BJADO6.10 17,5 A 10 poles BJADO6.20 17,5 A 20 poles PC6 V2 35 A 2 poles PC6 V2 35 A 3 poles PC6 V2 35 A 4 poles PC6 V2 35 A 10 poles EIP V2 AD2,5 V2 24 A OUMAD OUPAD OUTAD OUTA EXAD2 CEADO.6 CEADOE
Standard blocks 5, 6 and 8 mm. For multiple wires connections, the two wires need to be of the same gauge and nature (solid or stranded). Terminal block body mate-rial is UL 94 V0.
For drilling pattern see page: assembly and accessories
FEAD1 V0 th. 2,5 mm FEAD1 V0 th. 2,5 mm FEAD5 V0 th. 5,0 mm FEAD5 V0 th. 5,0 mm DCJ V2 FC2 DIA. 2 mm PC8 V2 50 A 2 poles PC8 V2 50 A 3 poles PC8 V2 50 A 4 poles PC8 V2 50 A 10 poles AD2,5 V2 24 A OUMAD OUPAD OUTAD OUTA EXAD2 CEADO.8 CEADOE
25 RCAL85
DH4/8.A.ADO3
9,5 mm 4 mm 0,5 - 0,8 Nm IP 20 .374" .157" 4.4 - 7.1 Ib.in NEMA 1
FEAD1 V0 th. 2,5 mm FEAD1 V0 th. 2,5 mm FEAD5 V0 th. 5,0 mm FEAD5 V0 th. 5,0 mm DCJ V2 FC2 DIA. 2 mm PC8 V2 50 A 2 poles PC8 V2 50 A 3 poles PC8 V2 50 A 4 poles PC8 V2 50 A 10 poles AD2,5 V2 24 A OUMAD OUPAD OUTAD OUTA EXAD2