Top Banner
Mail 15 Hoe Chiang Road Tower Fifteen #12-05 Singapore 089316 Web www.terasoffshore.com Call 65.6309.0555 Fax 65.6222.7848 Co.Reg.No. 200715754M Teras Fortress 92.00m x 54.00m x 6.0m Self Elevating Liftboat Length Overall: 92.00m Beam Moulded: 54.00m Depth Moulded: 6.00m Design Draft: 4.11m Leg Length: 137.25m Max. Operation Water Depth: 112m Accommodation: 250 Pax Gross Tonnage: Approx. 6,700 Tons
4

Teras Fortress Commercial Spec (24-6-15) Fortress_Commercial Spec 04-2-16 upd MJB...** This vessel specification is given in good faith & assumed to be correct. Details given are without

Mar 17, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Teras Fortress Commercial Spec (24-6-15) Fortress_Commercial Spec 04-2-16 upd MJB...** This vessel specification is given in good faith & assumed to be correct. Details given are without

Mail 15 Hoe Chiang Road Tower Fifteen #12-05 Singapore 089316

Web www.terasoffshore.com

Call 65.6309.0555

Fax 65.6222.7848

Co.Reg.No. 200715754M

Teras Fortress92.00m x 54.00m x 6.0m Self Elevating Liftboat

Length Overall: 92.00m

Beam Moulded: 54.00m

Depth Moulded: 6.00m

Design Draft: 4.11m

Leg Length: 137.25m

Max. Operation Water Depth:

112m

Accommodation: 250 Pax

Gross Tonnage: Approx. 6,700 Tons

Page 2: Teras Fortress Commercial Spec (24-6-15) Fortress_Commercial Spec 04-2-16 upd MJB...** This vessel specification is given in good faith & assumed to be correct. Details given are without

** This vessel specification is given in good faith & assumed to be correct. Details given are without guarantee.

** Owners reserved the right to amend the specifications without notification.

Mail 15 Hoe Chiang Road Tower Fifteen #12-05 Singapore 089316

Web www.terasoffshore.com

Call 65.6309.0555

Fax 65.6222.7848

Co.Reg.No. 200715754M

ADDITIONAL FEATURES

Speed Approx 6 knots

Helideck Suitable for Sikorsky S-92/S-61 Helicopter

Main Propulsion 2 x Berg AzimuthThruster Model BAT 523 CP, Z-Type, 1500kW @ 1200rpm

Bow Thruster 2 x Berg AzimuthThruster Model BAT 216L CP, L-Type, 710 kW @ 1200rpm

Electric Power Generators

2 x Caterpillar 3516Cgenset rated at 1825KW @ 1800rpm

EmergencyGenerator

2 x Caterpillar 3512C genset rated at 1360KW @ 1800rpm

EmergencyGenerator

1 x Caterpillar C18 genset rated at 400KW @ 1800rpm

Fresh Water Capacity 523.46MT

Accommodation 16 x 1 man with module toilet117x 2 men room with module toiletTotal: 250 pax including navigation crew

Free Deck SpaceDeck Sheathing

1,350 sqm1,089.2 sqm

Windlass 1 x Electrical – Hydraulic typeWindlass, 78mm U3 Chain diameter,29.5T Rated Pull 206.5T Brake Holding

Cranes 1 x Main Crane: LEC lattice boom Crane with max. lifting capacity 181.4 MT @ 10.55m; 50MT@ max. reach 36.56m; Fastline: 18ton @ all radius

1 x Aux. Crane: Pedestal offshore crane with max. lifting capacity 63.5MT@ 6.74m; 13.6MT@ max. reach 39.32m; Fastline: 9ton @ all radius

Jacking System 72 pinion drive gears units per liftboat, each gear 183.2MT lifting capacity

Jacking Speed 6FPM (without load);1.6FPM (with design load)

Steering System Electric steering only , with 2 stations

Fuel Oil Capacity 1410 MT

General SpecificationsGENERAL

Port of Registry/Flag Singapore

Official Number 398877

Class ABS

Notation A1, Accommodation

Service, Wind IMR, Self-

Elevating unit, AMS,

CRC, DPS-1, HELIDK

Built 2014, Triyards SSY,

Vietnam

Page 3: Teras Fortress Commercial Spec (24-6-15) Fortress_Commercial Spec 04-2-16 upd MJB...** This vessel specification is given in good faith & assumed to be correct. Details given are without
tuan.vm
Line
tuan.vm
Line
tuan.vm
Line
tuan.vm
Line
tuan.vm
Line
tuan.vm
Line
tuan.vm
Line
tuan.vm
Line
tuan.vm
Line
tuan.vm
Line
tuan.vm
Line
tuan.vm
Arrow
tuan.vm
Arrow
tuan.vm
Arrow
tuan.vm
Arrow
tuan.vm
Arrow
Page 4: Teras Fortress Commercial Spec (24-6-15) Fortress_Commercial Spec 04-2-16 upd MJB...** This vessel specification is given in good faith & assumed to be correct. Details given are without