TENDER FOR INTERIOR FURNISH- ING AND ALLIED WORKS AT ZONAL OFFICE, PUNJAB & SIND BANK, NARAINA DELHI Tender reference no: - PSB/ZO/GA/IF/01/2019 IMPORTANT DATES DATE OF ISSUE OF TENDER 07.06.2019 from 11.00 hrs. LAST DATE OF SUBMISSION OF QUE- RIES 15.06.2019 up to 17.00 hrs DATE OF PRE-BID MEETING 20.06.2019 at 15.00 hrs. LAST DATE OF SUBMISSION OF TEN- DER 11.07.2019 up to 14.00 hrs. DATE OF OPENING OF TENDER 11.07.2019 at 15.00 hrs. PUNJAB & SIND BANK, ZONAL OFFICE-2, B-38/39 3 RD FLOOR INDUSTRIAL AREA PHASE-1, NA- RAINA, NEW DELHI-110028 ARCHITECTS PAHWA ARCH TECH SERVICES , A-53, SECTOR 49,NOIDA-201301 MOBILE: + 91-8447747436 LANDLINE : + 91-120-4167183 Email :[email protected]
71
Embed
TENDER FOR INTERIOR FURNISH- ING AND ALLIED WORKS AT … · Tender for Interior Furnishing & Allied works at ZO Delhi -II, Punjab & Sind Bank / Page 4 of 70 breach of this contract
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
TENDER FOR INTERIOR FURNISH-
ING AND ALLIED WORKS
AT ZONAL OFFICE,
PUNJAB & SIND BANK, NARAINA
DELHI
Tender reference no: - PSB/ZO/GA/IF/01/2019
IMPORTANT DATES
DATE OF ISSUE OF TENDER 07.06.2019 from 11.00 hrs. LAST DATE OF SUBMISSION OF QUE-
RIES
15.06.2019 up to 17.00 hrs
DATE OF PRE-BID MEETING 20.06.2019 at 15.00 hrs. LAST DATE OF SUBMISSION OF TEN-
DER
11.07.2019 up to 14.00
hrs. DATE OF OPENING OF TENDER 11.07.2019 at 15.00 hrs.
In the event of the materials of makes called for are not available and alternative makes are ap-
proved (by the consultant) for incorporation in the work, the rates quoted shall be suitably amended
based on the price variation between the specified makes and alternative makes on the day the alter-
native makes are accepted.
1 FURNISHING WORK
2 ELECTRICAL
3 AIR CONDITIONING WORK
4 FIRE FIGHTING WORK
TOTAL AMOUNT = (1+2+3+4)
THE TOTAL COST IS EXCLUDING GST.
SUMMERY TOTAL COST OF INTERIOR FURNISHING WORK TO BE DONE AT PUNJAB & SIND BANK ZONAL OFFICE NARAINA NEW DELHI
Tender for Interior Furnishing & Allied works at ZO Delhi -II, Punjab & Sind Bank / Page 46 of 70
S. No. DESCRIPTION OF ITEM QUANTITY UNIT RATE(Rs) AMOUNT
A) Furnishing work1 PARTITION /PANELLING
Measurement of height shall be taken from finished floor level up tothe level of ceiling, in case of varying heights on either side ofpartition, average height shall considered. The rate include Provisionof extra frame work as necessary for skirting and making cut-outs forelectrical switch plates, switch boxes, light fittings light etc. makingprovision for laying conduit as per drawings & directions. All plywoodto be applied with 2 coats of fire retardant paint and 1 coat of woodpreservative with anti termite compound.
a Providing and Fixing of full height wooden partition made of 2 MMthick Aluminium tube frame The sections are placed @ 600 x 600MM C/C both ways and additionally at openings or ends as required.Sections are joined by Aluminium angle cleats and the frame is fixedto wall, floor & ceiling with suitable aluminium angles and fastenedwith steel screws.Frame size 50 x 50 MM with 9 MM thick BWR Plywith 1mm thk. High Gloss Laminate/ Laminate in approvedcolour,design, shape and size, inculding all exposed surface with teaklipping 6mm thk as required and instructed by Architect inculding AntiTermite Treatment.Complete in all respect and satisfacation ofArchitect/Engg.
45.00 Sq.mt
b Providing and Fixing of low height wooden partition (up to 4'-0" height)made of 2 MM thick Aluminium tube frame The sections are placed@ 600 x 600 MM C/C both ways and additionally at openings or endsas required. Sections are joined by Aluminium angle cleats and theframe is fixed to wall, floor with suitable aluminium angles andfastened with steel screws.Frame size 50 x 50 MM with 9 MM thickBWR Ply with 1mm thk.High Gloss Laminate/ Laminate as perapproved colour,design, shape and size,inculding Teak wood lipping6mm thk as required to be provided at every exposed section of plyinculding Anti Termite Treatment.Complete in all respect andsatisfacation,instructed by Architect/Engg.
31.42 Sq.mt
c Providing and Fixing of full height wooden glazed partition made of 2MM thick Aluminium tube frame The sections are placed @ 600 x600 MM C/C both ways and additionally at openings or ends asrequired. Sections are joined by Aluminium angle cleats and theframe is fixed to wall, floor & ceiling with suitable aluminium anglesand fastened with steel screws.Frame size 50 x 50 MM with 9 MMthick BWR Ply with 1mm thk. Laminate in approved colour,design,shape and size, & 12mm thick toughned glass panel fixed upto 8'-0"ht. inculding all exposed surface with teak lipping 6mm thk asrequired and instructed by Architect and teak wood door frame inbetween the partition. inculding Anti Termite Treatment.Complete inall respect and satisfacation of Architect/Engg.
36.98 Sq Mts
d Providing and Fixing of wooden Panelling of wall on hall and columnmade of 2 MM thick Aluminium tube frame The sections are placed@ 600 x 600 MM C/C both ways and additionally at openings or endsas required. Sections are joined by Aluminium angle cleats and theframe is fixed to wall, floor & ceiling with suitable aluminium anglesand fastened with steel screws.Frame size 25 x 50 MM with 9 MMthick BWR Ply with 1mm thk.High gloss Laminate/ Laminate inapproved colour,design, shape and size, inculding Anti TermiteTreatment.Complete in all respect and satisfacation of Architect/Engg.
70.00 Sq.mt
BOQ OF FURNISHING WORK AT PUNJAB & SIND BANK ZONAL OFFICE NARAINA
Page 49 of 72Tender for Interior Furnishing & Allied works at ZO Delhi -II, Punjab & Sind Bank / Page 47 of 70
e Providing and Fixing of wooden Panelling of wall on hall and columnmade of 2 MM thick Aluminium tube frame The sections are placed @600 x 600 MM C/C both ways and additionally at openings or ends asrequired. Sections are joined by Aluminium angle cleats and theframe is fixed to wall, floor & ceiling with suitable aluminium anglesand fastened with steel screws.Frame size 25 x 50 MM with 9 MMthick BWR Ply with 6mm colour lacquered glass in approvedcolour,design, shape and size, inculding Anti TermiteTreatment.Complete in all respect and satisfacation of Architect/Engg.
10.00 Sq.mt
2 DOORSa Providing and fixing frame less patch fitting Single door with 12mm
thick toughened (As per approved design & name/logo) with frameless glass fittings & two way floor springs (DORSET, OZONE orequivalent make). The item includes providing and fixing S.S. handle450 mm long on both side of glass, locks and fittings as per themanufacturer's specifications. complete to the satisfaction ofArchitect/ Bank's Engg
10.76 Sq.mt
b Providing and fixing 35 mm Flush doors with 1.0 mm thk. laminate onboth sides as per design. Edges of door to have 6mm thick Teakwoodlipping. The item includes Providing and fixing chaukhats made from75mm x 40mm TEAK wood members. Item includes all followingitems / finishes: hardware such as 4 nos. 125mm SS hinges, SS tower bolts,Door Closer,Mortise Locks with SS handles (Hettich, Dorset,Godrej). Item includes polishing all wooden surfaces with Deco paintRubbing poilishing etc including preparing base. Size of Door: 1000x2400mm including Chaukhats.
15.00 Sq.mt
3 False Ceiling:- (Measurement shall be taken of the plan area only)Suspending system and frame work shall match to complimentthe layout of A.C. Ducts / grills, electrical / fire protection wiring /fixtures, Return /supply Air grills etc. Rate to include provision of extraframe work needed due to layout referred above and fixtures etc.Rates to include necessary scaffolding.
4 Providing & fixing Gypsum Board False ceiling with Saint Gobain"ULTRA" Main ceiling sections at 1200 c/c & Cross members at 450c/c. The grid work to be suspended from ceiling with Hangers at every1200 c/c both directions, as per manufacturer's specifications. Falseceiling is finished with 12.5 mm thk. to be screwed to the frame. Theboard is finished with filling the tapered edges of the board withjointing compound and finishing with PAPER tape of INDIA GYPSUM.The ceiling is finished with acrylic Emulsion Paint inculding base asper approved manufacturer. The item includes all necessary cut outsfor electrical / air conditioning grills and necessary frame work forthem. Item includes Coves, curves, drops etc. (Only Plan area isconsidered for area calculations)
90.00 Sq.mt
Page 50 of 72Tender for Interior Furnishing & Allied works at ZO Delhi -II, Punjab & Sind Bank / Page 48 of 70
5 ARMSTRONG CEILING :- Providing & Fixing of Armstrong MineralFibre Suspended Ceiling System with Dune RH 99 (Bevelled Tegular)Edge Tiles with Armstrong 15mm exposed GRID. Size-600x600x16mm. The tiles should have Humidity Resistance (RH) of 99%, NRC0.5,Light Reflectance 83%, Thermal Conductivity k = 0.052 - 0.057w/m K, Colour White, Fire Performance UK Class 0/Class 1 (BS 476Part 6 & 7), in module size of 600x600 x 16mm with Anti Microbialcoating on the face of the tile, suitable for Green Buildingapplication,with Recycled content of 39%.The tile shall be laid onArmstrong Suprafine XL 38 with 15MM wide T - section flanges colourwhite having rotary stitching on all T sections i.e. the Main Runner &1200 mm Cross Tees with a web height of 38mm and a load carryingcapacity of 14Kgs/M2 & minimum pull out strength of 100Kgs. . The TSections have a Galvanizing of 90 grams per M2 and need to beinstalled with Suspension system of Armstrong make. INSTALLATION: To comprise main runner spaced at 1200mmcentres securely fixed to the structural soffit using Armstrongsuspension system (specifications below) at 1200mm maximumcentre. The First/Last Armstrong suspension system at the end ofeach main runner should not be greater than 450mm from the
adjacent wall.
Flush fitting 1200mm long cross tees to be interlocked between mainrunners at 600mm centre to form 1200 x 600 mm module. Cut crosstees longer than 600mm require independent support. 600x600mmmodule to be formed by fitting 600mm long flush fitting cross teescentrally between the 1200mm cross tees. Perimeter trim to beArmstrong wall angles of size 3000x19x19mm, secured to walls at450 mm maximum centres. Installation to be carried out byArmstrong Trained Installation team & Installation should be carriedout as per Armstrong recommended procedure.ARMSTRONG SUSPENSION SYSTEM accessories manufacturedand supplied by Armstrong World Industries consisting of M6 AnchorFasteners with Vertical Hangers made of Galvanised steel of size 26x 26 x 25 x 1.2mm with a Galvanised Thickness of 80gsm, A pretightened Hanger wire of dia – 2.5 mm of 1.8 m length., thickness of80gsm and a tensile strength of 344-413 MPa, along with Adjustablehook clips of 0.8mm thick, galvanised spring steel for 2.68 mm with aminimum pull strength of 110 kg. The adjustable clip also consists of a 3.5 mm aquiline wire to be used with the main runner. (ARMSTRONG“DUNE RH 99 (Bevelled Tegular) EDGE TILES WITH ARMSTRONG15mm Exposed” SYSTEM)
130.00 Sq.mt
ARMSTRONG SUSPENSION SYSTEM accessories manufacturedand supplied by Armstrong World Industries consisting of M6 AnchorFasteners with Vertical Hangers made of Galvanized steel of size 26x 26 x 25 x 1.2mm with a Galvanized Thickness of 80gms/ sq.m, Apre Straightened Hanger wire of dia – 2.65 mm of 1.8 m length.,thickness of 80 gsm/sq.m and a tensile strength of 344-413 MPa,along with Adjustable hook clips of 0.8mm thick, galvanized springsteel for 2.68 mm. The adjustable clip also consists of a 3.5 mmaquiline wire to be used with the main runner.
ARMSTRONG SUSPENSION SYSTEM accessories manufacturedand supplied by Armstrong World Industries consisting of M6 AnchorFasteners with Vertical Hangers made of Galvanized steel of size 26x 26 x 25 x 1.2mm with a Galvanized Thickness of 80grm/ sq.m, A preStraightened Hanger wire of dia – 2.65 mm of 1.8 m length., thicknessof 80 g/sq.m and a tensile strength of 344-413 MPa, along withAdjustable hook clips of 0.8mm thick, galvanized spring steel for 2.68mm. The adjustable clip also consists of a 3.5 mm aquiline wire to beused with the main runner.
6 FURNITURE
Page 51 of 72Tender for Interior Furnishing & Allied works at ZO Delhi -II, Punjab & Sind Bank / Page 49 of 70
a DGM TABLE to have 18-19 BWR Ply , finished with 1mm thkLaminate all edges of table and front or side. All internal surface oftable to be finished with white paint..Drawer unit to be made fromonly FASCIA 19mm BWR ply but the inner drawers made from 12mmBwr Ply.and 19mm BWR ply FASCIA finished with 1mm thkLaminate .The drawers to run on telescopic drawer channels (Hettich,Kaff, ozone). Drawer units to have two smaller and one biggerdrawers.and locking arrangement (Godrej/ Hettich/ Dorset). InculdingTeak lipping 6mm thk as required to be provided at every section ofply.Footrest of 75x50mm 2nd class teakwood member to be fixed foreach table with Deco paint on expoed teak wood surface /lipping, therate to include all hardware such as drawer channels, S.S handles,single lock for three drawers etc. The item also includes a key-boardtray running on telescopic channel, made from 19mm BWR Plyfinished with 0.8mm laminate on top and teakwood round moulding infront (size of key board 560x450) readymade CPU trolley with castorsetc The table size is taken to be 2400mm wide x 900mm depthx750mm height.(As per drawing)
1.00 No
b AGM/CHIEF MANAGER TABLE to have 18-19 BWR Ply , finishedwith 1mm thk Laminate all edges of table and front or side. All internalsurface of table to be finished with white paint..Drawer unit to bemade from only FASCIA 19mm BWR ply but the inner drawers madefrom 12mm Bwr Ply.and 19mm BWR ply FASCIA finished with 1mmthk Laminate .The drawers to run on telescopic drawer channels(Hettich, Kaff, ozone). Drawer units to have two smaller and onebigger drawers.and locking arrangement (Godrej/ Hettich/ Dorset).Inculding Teak lipping 6mm thk as required to be provided at everysection of ply.Footrest of 75x50mm 2nd class teakwood member tobe fixed for each table with Deco paint on expoed teak wood surface/lipping, the rate to include all hardware such as drawer channels, S.Shandles, single lock for three drawers etc. The item also includes akey-board tray running on telescopic channel, made from 19mm BWRPly finished with 0.8mm laminate on top and teakwood roundmoulding in front (size of key board 560x450) readymade CPU trolleywith castors etc The table size is taken to be 1800mm wide x900mm depth x750mm height.(As per drawing)
2.00 No
C Providing and fixing Side Credenza/ table made from 19mm BWRPly for sides, shelves, top and shutters. The table exposed areasfront,top and sides to be finished in 1mm thk Laminate All internalsurface of table to be finished with white paint, all edges of tableInculding Teak lipping 6mm thk as required to be provided at everysection of ply.complete with base as required. Item includes allhardware such as Self closing hinges, SS handles, Locks etc.complete. Rest of specifications to be same as for main furniture. sizeof side table 900 x380 x 750
12.00 No
d officer table to have 18-19 BWR Ply , finished with 1mm thk Laminateall edges of table and front or side. All internal surface of table to befinished with white paint..Drawer unit to be made from only FASCIA19mm BWR ply but the inner drawers made from 12mm Bwr Ply.and19mm BWR ply FASCIA finished with 1mm thk Laminate .Thedrawers to run on telescopic drawer channels (Hettich, Kaff, ozone).Drawer units to have two smaller and one bigger drawers.and lockingarrangement (Godrej/ Hettich/ Dorset). Inculding Teak lipping 6mmthk as required to be provided at every section of ply.Footrest of75x50mm 2nd class teakwood member to be fixed for each table withDeco paint on expoed teak wood surface /lipping, the rate to includeall hardware such as drawer channels, S.S handles, single lock forthree drawers etc. The item also includes a key-board tray running ontelescopic channel, made from 19mm BWR Ply finished with 0.8mmlaminate on top and teakwood round moulding in front (size of keyboard 560x450) readymade CPU trolley with castors etc The tablesize is taken to be 1500mm wide x 750mm depth x750mm height.(Asper drawing)
9.00 No
Page 52 of 72Tender for Interior Furnishing & Allied works at ZO Delhi -II, Punjab & Sind Bank / Page 50 of 70
e Clerk Table to have 18-19 BWR Ply , finished with 1mm thkLaminate all edges of table and front or side. All internal surface oftable to be finished with white paint.Drawer unit to be made from onlyFASCIA 19mm BWR ply but the inner drawers made from 12mm BwrPly.and 19mm BWR ply FASCIA finished with 1mm thk Laminate.The drawers to run on telescopic drawer channels (Hettich, Kaff,ozone). Drawer units to have two smaller and one bigger drawers.andlocking arrangement (Godrej/ Hettich/ Dorset). Inculding Teak lipping6mm thk as required to be provided at every section of ply.Footrestof 75x50mm 2nd class teakwood member to be fixed for each tablewith Deco paint on expoed teak wood surface /lipping, the rate toinclude all hardware such as drawer channels, S.S handles, singlelock for three drawers etc. The item also includes a key-board trayrunning on telescopic channel, made from 19mm BWR Ply finishedwith 0.8mm laminate on top and teakwood round moulding in front(size of key board 560x450) readymade CPU trolley with castors etcThe table size is taken to be 1500mm wide x 600mm depth x750mmheight.(As per drawing)
20.00 No
f Providing and fixing May I help YOU counter in Curved shape with19mm BWR Ply finished with 1.0 mm laminate in two or moreshades. The Customer top, which is at 230 mm higher than workingtop, customer top & front to be finished in 12mm thk acrylic solidsurface thermoformed and (corian, LG, Merino) fixed over 12 mmBWR Ply with provision for LED strip in cove as per design & Details.inculding Drawer unit to be made from only FASCIA 19mm BWR plybut the inner drawers made from 12mm Bwr Ply.and 19mm BWR plyFASCIA finished with 1mm thk Laminate .The drawers to run ontelescopic drawer channels (Hettich, Kaff, ozone). Drawer units tohave two smaller and one bigger drawers.and locking arrangement(Godrej/ Hettich/ Dorset). Inculding Teak lipping 6mm thk as requiredto be provided at every section of ply.Footrest of 75x50mm 2ndclass teakwood member to be fixed for table with Deco paint onexposed teak wood surface /lipping, the rate to include all hardwaresuch as drawer channels, S.S handles, single lock for three drawersetc. The item also includes a key-board tray running on telescopicchannel, made from 19mm BWR Ply finished with 1.0mm laminate ontop and teakwood round moulding in front (size of key board 560x450)readymade CPU trolley with castors etc The table size is taken to be1350 mm wide x 650mm depth x750mm height.(As per drawing) Allinternal surface of table to be finished with white paint.rkingarrangement of cove light in layers as per design
1.00 No
7 STORAGEa Providing and fixing Storage cabinet 380 mm deep and 750/1200 mm
high length as/deign as shown in details with top all sides, shelves tobe 18-19 mm thk. BWR ply with 6mm BWR ply to be fixed at the backfinished with 0.8mm laminate. The shutters/sides/top to be 18-19mmBWR ply,finished with 1mm thk laminate. All internal surfaces to befinished with white Paint. All edges of sides, shelves and shutters tohave 2mm PVC Edge binding tape as per details, complete includingS.S. long handles, self closing hinges, locks, etc. complete to thesatisfaction of Architect /Bank's Engg. (Only front elevation to beconsidered for area calculation)
30.00 Sq.mt
b Providing and fixing over head storage cabinet in pantry 380mm deepand 675mm high length as/deign as shown in details with all sides,shelves to be 18-19 mm thk. BWR ply with 6mm BWR ply to be fixedat the back with 0.8mm laminate. The shutters to be 18-19mm BWRply, with 1.0 mm laminate. All internal surfaces to have 0.8m laminate.All edges of sides, shelves and shutters to have 2mm PVC Edgebinding tape as per details, complete including S.S. long handles, selfclosing hinges, locks, etc. complete to the satisfaction of Architect/Bank's Engg. Only front elevation to be considered for areacalculation.
2.00 Sq.mt
Page 53 of 72Tender for Interior Furnishing & Allied works at ZO Delhi -II, Punjab & Sind Bank / Page 51 of 70
c Providing and fixing storage cabinet (below platfrom) in pantry TheFront frame and shutters inculding partition to be 18-19mm BWR ply,with 1.0 mm laminate. All edges of shutters to have 2mm PVC Edgebinding tape as per details, complete including S.S. long handles, selfclosing hinges, locks, etc. complete to the satisfaction of Architect/Bank's Engg. Only front elevation to be considered for areacalculation.
2.00 Sq.mt
8 Fixing in Granite pantry counter in counter etc cutting and making
complete in all respect inculding the pantry sink (size 600x600) and
sink mixture and angle stop cock in pantry , P.V.C. waste pipe for
sink including P.V.C. waste fittings 32mm dia up to trap complete in
all respect as instructed by Architect/Engg.
2.00 Sq.mt
9 Flooring :-Providing and laying 10-12mm thick Vitrified tiles of
Johnson /Somany make or approved equivalent and of approved
shade of size as per drawing in floors over 20mm (average) base of
match finished floor level mentioned and to match the neighboring
floor finish and jointed with epoxy grout of approved shade from
as/existing or equivalent brand all complete as directed complete.
Rate to include forming pattern in the flooring like border, skirting, cut
tiles, Protecting of the tile till hand over date by POP., etc complete in
all respect. (Base rate of Vitrified tiles Rs. 600/- per Sq.mt )
230.00 Sq Mts
10 Providing and laying designer cermic glazed floor tiles in toilet & Pantry area (thikness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approves make in colours such as white,ivory Grey,Fume Red Brown,laid on 20mm thick Cement Mortar 1:4(1 cement 4Coarse sand) Inculding pointing the joints with white Cement and Matching Pigment etc..complete in all respect.(base rate Rs 50 sq.ft)
20.00 Sq Mts
11 Tiles in wall of toilet with Designer tiles of kajaria/johnson ( Base
Rate of Tile s Rs 50 SQ.FT)
50.00 Sqm
12 P/L 12/19 mm thick plaster of cement mortar 1:4 (1cement: 4 sand) 150 sq.mt.
13 Dismantalling of exisitng flooring Fasle celling/partition/all Type
Furnitures and disposing of malba from site
1.00 Job
Total Furnishing (A)
B) PLUMBING WORK 1 Providing and fixing white vitreous china wash basin including making
all connections but excluding the cost of fittings:
a) wash basin of size 610x500mm. Parryware Code C8418 2.00 Nos2 Providing and fixing white vitreous china flat back or wall front urinal
basin of Parryware Model Code C0575 with Automatic Flushing retrofit EFS model No DC-C8087.
2.00 Nos
3 Providing and fixing white vitreous china pedestal type (European type/ wash down type) water closet pan. Of parryware Cascade next including Cistern, lid complete in all respect(base rate 10000.00)
2.00 Nos
4 Providing and fixing P.V.C. waste pipe for wash basin including P.V.C. waste fittings complete.
a) 32 mm dia 2.00 Nosb) 40mm dia 2.00 Nos5 Providing and fixing brass bib cock of approved quality: (Jaguar
Model Florentine)Nos
a) 15 mm nominal bore 4.00 Nos6 Angle Cock Jaguar Florentine 2.00 Nos7 Master stop cock Jaquar/ Hindware/Grohe make, heavy duty 4.00 Nos8 Jet in commodes 2.00 Nos
RENOVATION OF TOILETS
Page 54 of 72Tender for Interior Furnishing & Allied works at ZO Delhi -II, Punjab & Sind Bank / Page 52 of 70
9 Providing and fixing UPVC soil pipes confirming to IS:1729 on walls including filling the joints with specialised jointing solutions and fixed with G.I. clamps embedded in cement concrete blocks 100x100x100 of 1:2:4 (1 cement :2 coarse san:4 stone aggregate) including cutting holes and making good the walls etc. item includes Providing and fixing UPVC pipes specials such as door bend, horn bend, plain bend, cowls, sockets, door "T", 'Y' and 'T' junctions(both single and double etc. including fixing with cement jute admixture complete as directed
a For 100mm pipes 15.00 R.Mtb For 150mm pipes 5.00 R.Mtc For 75mm pipes 5.00 R.Mtd For 50mm pipes 5.00 R.Mt
10 Providing and fixing UPVC cowls for 150 mm pipes 3.00 Each11 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (NOTE: Concealed work, including cutting chases and making good the walls etc.)
a 25 mm nominal outer dia Pipes 30.00 R.Mtb 15 mm nominal Inner dia Pipes 40.00 R.Mt
12 Provinding and fixing on wall face unplasticised PVC moulded fittings/ accessories for unplasticised rigid PVC pipes conforming to IS : 13592 type A, Inculding jointing with seal ring conforming to IS : 5382, leaving 10mm Gap for thermal expansion.
Single tee with doora 75x75x75mm 4.00 Eachb 110x110x110mm 4.00 Each
Bend 87.5*a 75 mm bend 7.00 Eachb 110mm bend 8.00 Each
13 Provinding and fixing unplasticised - PVC pipe clips of approved design to unplasticised PVC pipes by means of 50x50x50mm hardwood plugs, screwed with M.S. screws of required length inculding cutting brick work and fixing in cement mortar 1:4(1cement : 4 coarse sand) and making good the wall etc. complete
75mm 8.00 Each110mm 15.00 Each
Total Amount (A+B)
Page 55 of 72Tender for Interior Furnishing & Allied works at ZO Delhi -II, Punjab & Sind Bank / Page 53 of 70
S.No. DESCRIPTION Amount
A) MV PANEL BOARDS
B) MV CABLES
C) DISTRIBUTION BOARDS
D) POINT WIRING
E) TELEPHONE SYSTEM
F) COMPUTER DATA NETWORKING
G) SUPPLY & INSTALLATION FANS FIXTURES & LIGHTS
H) EARTHING
I) DISMANTALING
TOTAL
PREAMBLE TO BOQ1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
i)
ii)
iii)
iv)
v)
vi)
vii)
9.0
10.0
11.0
12.0
13.0
14.0
15.0
16.0
17.0
18.0
Testing and commissioning shall be carried out as per IS 732-1989 for the installation. The record of test results shall bemaintained and submitted to the engineer in charge who would check the same at random.
The tender shall be filled in ink and any cutting / overwriting shall be attested by the tenderer. Rates shall be quoted bothin figures and words. If there is discrepancy between the rates in figures and words, then rates in words shall be final.
Totaling errors or missing amounts shall be corrected and incorporated in tendered amount.
Continuous earth wire shall run alongwith circuit wiring and point wiring. All switch boxes and fixtures shall be earthed.Only solid conductor earth wire shall be used for earthing.
Where only conduits are laid for other services 16 SWG steel wire shall run in the conduit for pulling the wires at laterdate, by other agencies.
Tenderer may note that there are lot of RCC walls in which conduits and outlet boxes switch boxes are to be provided.Costing of such walls shall be done with mixer shutterings. Conduits and boxes shall be laid before pouring the concrete.The outlet boxes, J.boxes, switch boxes shall be touch welded to the reinforcement before concreting. Only deep metallicJ.boxes shall be used with PVC conduit as well.
All requirements for successful completion of the work whether mentioned in BOQ, specifications land drawings or not.
In the event of conflict between BOQ, specifications and drawings, the most stringent shall apply. The decision ofArchitect / Engineer incharge / Consultant shall be final and binding.
The quantities of the items in the BOQ are for general guidance only based on the consultants drawings and documents.The contractor shall be paid for actual quantities as per schedule rates.
Contractor shall visit the site before quoting the rates and satisfying himself about the working conditions. Since this is atall building, hoisting the material to upper levels may be taken into account white quoting the rates. No extra claim onthis account shall be entertained.
Approval of all makes of material to be supplied out of approved list, shall be obtained by the contractor. Sample of thematerial shall be kept at site to check with the material actually installed at site.
Engineer in charge may get the material tested at authorized labs. In case material is found under specifications as per
IS, same shall be replaced by the contractor. The test fee for 1st test shall be borne by the client but for subsequent test,
The rates of all the items of the BOQ shall include the cost of :-
All materials, fixing hardware, accessories, tools and plants, freight, insurance, labour, taxes, duties, testingcommissioning and of the work, as per specifications and drawings.
Wastage on material and labour.
Loading, unloading, handling charges, hoisting the material to all upper levels.
Execute the work as per specifications and drawings to the full satisfaction of engineer incharge.
All liabilities, obligations and risks arising out of conditions of contract.
ELECTRICAL BOQ OF PUNJAB & SIND BANK ZONAL OFFICE NARAINA
The installation and testing shall also be as per specifications and as per direction and satisfaction of Engineer in charge.
Contractor shall submit the shop drawings for approval by consultants / Engineer in charge. The work shall be carried outas per the approved shop drawings.
Panels shall be fabricated as per specifications after approval of fabrication drawings by consultant / Engineer incharge.
All Electrical panel must have provision of potential free contacts for BMS/FAS.
All Electrical panel must have digital type energy meter with RS 485 port.
The work shall be executed as per relevant specification and drawings.
All material and equipment shall be as per specification and as per approved makes of material. Where specificationsare not available the material shall be as per Indian standard specifications. The quantities and capacities of theequipments shall meet the requirement for successful completion of the work.
Page 56 of 72Tender for Interior Furnishing & Allied works at ZO Delhi -II, Punjab & Sind Bank / Page 54 of 70
19.0
20.0
21.022.0
S.No. Description Unit Qty. Rate(Rs) Amount
A) MV PANEL BOARDS Design, fabrication, loading, unloading at store, installaton, testing &commissioning as directed by Engineer-in-Charge, of LT Panelsfabricated out of 2mm thick for structural members (Load bearingmembers) and 1.6mm thick for door and covers (Non load bearingmembers) CRCA sheet in cubicle compartmentalize free standingfloor mounted, dust and vermin proof with reinforcement of suitablesize angle iron, channel 'T' irons and / or flats wherever necessary, 16gauge CRCA sheet steel shall be used for final distribution panels.Cable gland plates shall be provided on top as well as at the bottom ofthe panels. Panels shall be treated with all anticorrosive processbefore painting as per specifications with 2 coats of zinc chromateprimer and final approved shade of enamelled paint. 2 Nos. earthingterminals shall be provided for all distribution panels. Panels shall besuitable for 415V, 3-phase, 4-wire, 50Hz supply system and with 15%spare space, lifting hooks shall also be provided in case of largepanels. Panel must be BMS/FAS Compatible.
Approval shall be taken for each panel before fabrication. Galvanized
hardwares with zinc passivation shall be used in fabrication of panels. General Notes:
1.0 MCCB:MCCBs shall be used with Thermal Magnetic Based releases upto250A and microprocessor based Over Load, Short Circuit / Earth Faultrelease.
2.0 Breaking capacity mentioned is Ics value.
3.0 This BOQ to be read in conjunction with technical specifications and
Single Line Diagram (attached for reference). If any discrepancy
occurs that should be brought to the notice of Client/Consultant before
quoting the price otherwise stringent condition will be deemed to have
been considered.4.0 All MCCBs shall be provided with rotary operating handle and
ON/OFF lamps.5.0 All meters shall be digital type (unless otherwise specified) with RS
485 Port.6.0 All Incoming and outgoing breaker must have provision of Potential
free contacts for BMS/FAS.7.0 All MCBs shall be motor duty type.
8.0 All current/voltage transformer shall be cast resin type.
9.0 All indicating lamps shall be LED type.
10.0 Current density for Al. bus bars shall not be more than 0.8A/Sqmm.Rating of Bus bar is after considering all derating factors. (Bus barsizing calculation to be submitted for approval.)
11.0 All internal control wiring shall be heat resistant type.
12.0 All TP feeders shall be provided with Isolable neutral link.
13.0 Bus bar chamber & cable entry both shall be provided at top only.
14.0 All feeders shall be provided with door interlocked with door defeat,pad lock facility.
15.0 Live parts shall not be accessible after opening the door, Transparentacrylic sheet to be provided to cover the same.
16.0 Spare contacts of MCCBs / Relay / Contactor shall be wired uptoterminal block.
All connections shall be through, aluminium ferrules for aluminum conductors and copper ferrules for copper conductorcables.
Earth wire with point wiring, circuit wiring, shall be of green colour with solid conductor.
DBs shall be circuit numbered. As built drawing shall be prepared by the contractor after successful completion of the work these drawings shallincorporate the actual layouts, routes of cables and conduits with sizes, locations of outlets, DBS switch rooms panel,Tag blocks EPABX, Switches servers, fire detectors, zonal and main fire panels, location of CCTV cameras, monitors,etc. sets of blue prints of switch drawings shall be submitted to the Engineer incharge for verification with actual layout atsite and for record.
Page 57 of 72
Tender for Interior Furnishing & Allied works at ZO Delhi -II, Punjab & Sind Bank / Page 55 of 70
17.0 20% spare control terminal to be provided.
18.0 All incoming/outgoing cables shall be terminated on links/terminals.
1.0 MV PANEL I. INCOMING
a) 1 No-100 Amp,25KA,4P MCCBII. METERING & INDICATION SEBa) CT for metering 100/5A Class-1, 15VA - 3 Nos. b) Multifunction Meter-1 no.c) Red, Yellow & Blue indicating lights with control MCB of 2A - 2 Set
III OUTGOING
a) 63 A TPN MCB (10KA) -4 No.
b) 40A TPN MCB (10KA) -2 Nos.
c) 32A DP MCB (10KA) -2 Nos Nos. 1
TOTAL CARRIED OVER TO SUMMARY ( A )
B) MV CABLES
1 Supplying, Laying, testing & commissioning of the following sizes of XLPE Al. Conductor armoured cables of 1.1KV grade on the surface of wall or on existing cable trays complete with hangers, properclamps fixing hardware etc. as required
a) 3.5 C x 50 Sq. mm Al. Cable Mtrs 30
b) 4 C x 25 Sq. mm Al. Cable Mtrs 35
c) 4 C x 16 Sq. mm Al. Cable Mtrs 20
d) 4 C x 10 Sq. mm Al. Cable Mtrs 20
c 4x6 Sqmm Copper Wire with 25 mm conduit Mtrs 20
2 Suppling, making, testing & commissioning of end termination with brass mettalic double compression glands suitable for the following sizes of XLPE Al. conductor arnoured cables including proper sizes of copper thimbles etc. as required.
a) 3.5 C x 50 Sq. mm Al. Cable Nos 8
b) 4 C x 25 Sq. mm Al. Cable Nos 8
c) 4 C x 16 Sq. mm Al. Cable Nos 8
d) 4 C x 10 Sq. mm Al. Cable Nos 8
c 4x6 Sqmm Copper Wire with 25 mm conduit Nos 8
TOTAL CARRIED OVER TO SUMMARY ( B )
C) DISTRIBUTION BOARDS Supplying, installation, testing & commissioning of following type wall mounted Horizontal TPN/SPN distribution board of double door type design made out of 16 gauge MS sheet with supplying and fixing following accessories including painting, interconnections, painting, earthing and labeling etc. as required.
1.0 8 WAY TPN DB (PDB)Incoming
a) 63Amp TPN MCB (10KA) - 1 No
63Amp DP RCCB (30mA) - 3 Nos
Busbars
b) 100 Amp TPN copper busbars - 1 Set
Outgoing
c) 10/16/20/25 Amp SP MCB (10KA) - 24 Nos Set 1
Neutral links - 3 Nos (Separate for each phase)
2.0 4 WAY TPN DB (LDB)
Incoming
a) 40Amp TPN MCB (10KA) - 1 No
40Amp DP RCCB (30mA) - 3 Nos
Busbars
b) 100 Amp TPN copper busbars - 1 Set
Outgoing
c) 10/16/20/25 Amp SP MCB (10KA) - 12 Nos Set 1
Neutral links - 3 Nos (Separate for each phase)
3.0 6 WAY TPN DB (UPS)
Page 58 of 72Tender for Interior Furnishing & Allied works at ZO Delhi -II, Punjab & Sind Bank / Page 56 of 70
Incoming
a) 63Amp TPN MCB (10KA) - 1 No
b) 63Amp DP RCCB (30mA) - 3 Nos
Busbars
c) 100 Amp TPN copper busbars - 1 Set
Outgoing
d) 10/16/20/25 Amp SP MCB (10KA) - 18 Nos
e) Neutral links - 3 Nos Set 1
(Separate for each phase)
4.0 63 Amp. 4 P ,10ka MCB with Box for UPS Set 2
TOTAL CARRIED OVER TO SUMMARY ( C )
D) POINT WIRING 1.0 Wiring for switch controlled Light Point with 3 x 1.5 Sq. mm PVC
insulated FRLS multistrand copper conductor 1100 Volt grade wires in PVC surface/recessed conduit with accessories including cost of providing saddles etc for surface conduiting and/or cost of cutting and filling chases for recessed conduiting and including the cost of supplying and fixing a 6 Amp 240 Volt grid plate mounted switch with moulded cover plate in zinc chromate passivated MS box, and costing circuit wiring with 3 x 2.5sq. mm 1100 volt grade PVC insulated FRLS Multistrand copper conductor wires, inPVC conduit complete as per specifications and as required.
(i) Primary Point Points 50
(ii) Secondary Point Points 35
3.0 Wiring for 5 pin 6 A Light plug point with 3 x 1.5 Sq.mm PVC insulated FRLS multistrand copper conductor 1100 Volt grade wires in recessed/surface FRLS PVC conduit with accessories including cost of providing saddles etc for surface conduiting and/or cost of cutting & filling chases for recessed conduiting, including the cost of providing & fixing 1 No. Modular type 3 pin 6 A socket outlet controlled by 6 A switch in zinc chromate passivated MS box, and circuit wiring with 3 x 2.5 sq mm complete as per specfications and as required.
Points 10
a) Wiring for 3 nos. 5 pin 6 A Light plug point controled by 6 A Switch with 3 x 2.5 Sq.mm PVC insulated FRLS multistrand copper conductor 1100 Volt grade wires in recessed/surface PVC conduit with accessories including cost of providing saddles etc for surface conduiting and/or cost of cutting & filling chases for recessed conduiting, including the cost of providing & fixing 1 No. Modular type 3nos.5 pin 6 A socket outlet controlled by 6 A switch in zinc chromate passivated MS box, and circuit wiring with 3 x 2.5 sq mm complete as per specfications and as required.
Points 35
4.0 Wiring for following. 6 pin 6/16 A Power plug point controlled by 1 No. 16A Switch with 3 x 4.0 Sq. mm PVC insulated FRLS multi strand copper conductor 1100 Volt grade wires in recessed/surfacePVC conduit with accessories including cost of providing saddles etc for surface conduiting and/or cost of cutting chases for recessed conduiting, including the cost of providing & fixing 1 No. Modular type 6 pin 16 A socket outlet controlled by 1 No. 16 A switch in zinc chromate passivated MS box, complete as per specification and as required.
Points 5
5.0 Wiring for ceiling/wall fan Point with 3 x 1.5 Sq. mm PVC insulated FRLS multi strand copper conductor 1100 Volt grade wires in surface / recessed, PVC conduit with accessories including cost of providing saddles etc for surface conduiting and/or cost of cutting and filling chases for recessed conduiting and including the cost of supplying and fixing a 6 Amp 240 Volt grid plate mounted switch & 300W electronic regulator with moulded cover plate in zinc chromate passivated MS box, and including the cost of circuit wiring with 3 x 2.5sq. mm 1100 volt grade PVC insulated FRLS multi strand copper conductor wire, inPVC conduit complete as per specifications and as required.
Points 20
Page 59 of 72
Tender for Interior Furnishing & Allied works at ZO Delhi -II, Punjab & Sind Bank / Page 57 of 70
6.0 Wiring for exhaust fan Point with 3 x 1.5 Sq. mm PVC insulated FRLS multi strand copper conductor 1100 Volt grade wires in surface / recessed PVC conduit with accessories including cost of providing saddles etc for surface conduiting and/or cost of cutting and filling chases for recessed conduiting and including the cost of supplying and fixing a 6 Amp 240 Volt grid plate mounted switch with moulded cover plate in zinc chromate passivated MS box, and including the cost of circuit wiring with 3 x 2.5sq. mm 1100 volt grade PVC insulated FRLS multi strand copper conductor wire, inPVC conduit complete as per specifications and as required.
Points 6
7.0 Wiring for 20A Single Phase metal clad socket outlet with 2 x 4 +1 x 2.5 sqmm PVC insulated FRLS multistrand copper wire of 1100 volt grade in surface / recessed PVC conduit pipe with accessories including supply and fixing 20A 3pin metal clad plug and socket and 20A SP MCB (MD) in IP 44 Poly carbonate box complete as per specification and as required.
Points 11
8.0 Providing and fixing of following sizes of PVC Flexible Conduits suitable for various applications, halogen free, oil and petrol resistant, flame retardant, self extiguishing, high compressive strength and good wearing properties along with connectors complete with conduit gland & all accessories required.
a) 25mm dia RM 100
TOTAL POINT WIRING
E) TELEPHONE SYSTEM1.0 Supply & fixing the following sizes of PVC conduit in recessed or on
surface of wall . False ceiling including cutting the wall and making good the same as required.
a) 25 mm dia Mtrs 275
2.0 Supply and fixing of RJ11 moduler Telephone outlet in Zinc chromate passivated M.S. Box and Modular Plate including cost of M.S.box, modular plate and connections etc as required.
Nos. 35
3.0 Supply & fixing the following sizes of 16 SWG Krone telephone tag blocks housed in suitable sizes of powder coated MS boxes with hinge cover complete as required.
b) 20 pair telephone tag block Nos. 1
4.0 Supplying & laying the following sizes of PVC insulated and overall sheathed taped telephone cables of 0.51mm dia size inPVC conduit recessed in wall or on surface of wall including cutting the chases in making good the same and connection etc. complete as required. (From TTB on Ground Floor to Upper Floor)
a) 2 pair telephone wire Mts 300
c) 20 Pair telephone cable Mtrs. 20
5.0 Supply & fixing of EPABX system model Compact series 824 (8 P&T & 24 Extensions) make :- Star ,Panasonic
Nos. 1
6.0 MDF (50Pair) (Krone) Nos. 1
7.0 Sensor Nos 1
TOTAL CARRIED OVER TO SUMMARY ( E )
Note :- Only conduiting & cabling has been included in the BOQ for TV System. The High end equipment and signal booster amplifier etc. shall be provided by specialised agency.
F) COMPUTER DATA NETWORKING 1.0 Supply & fixing the following size of PVC conduit in Floor/Surface of
wall, including cutting the Floor/Wall and make the good the same as required (For Switcher to Data point.)
a) 25 mm dia Mtrs 200
2.0 Supply and fixing flush steel box for computer data outlet dully recessed in wall complete computer outlet RJ 45 including connect etc. required.
Nos. 35
3.0 Supply and drawing of cat 6 Data cable in existing conduit with suitable clamp and saddles and other accessories required making connection on both the ends.
Mtrs 300
4.0 9U Rack 9( D Link) Nos. 15.0 48 port Switch ( d Link) Nos. 1
Page 60 of 72Tender for Interior Furnishing & Allied works at ZO Delhi -II, Punjab & Sind Bank / Page 58 of 70
TOTAL CARRIED OVER TO SUMMARY ( F )
G)
1.0 Supply & installation , testing & commissioning of 48/36/24" ceiling Fan complete with all accessories such as blades, canopy etc. including wiring the down rod with 3 x 1.5 sq mm FRLS PVC insulated multistranded copper conductor wires and earthing the fans etc. complete as required.
Nos. 2
2.0 Supply & installation , testing & commissioning of wall Mounted Fan 450mm Sweep. (Make :- Havells,Crompton,Philips) complete with all accessories such as blades, canopy etc.Connection with 3 x 1.5 sq mm FRLS PVC insulated multistranded copper conductor wires from the socket outlet to the fan earthing etc. . complete as required.(Wall Mounted Fans Bracket fans sweep 400 mm)
Nos. 20
3.0 Supply & installation, testing & commissioning of 12/9" exhaust fans on existing opening in wall including all fixing hardware, louvers, shutters etc. Connection with 3 x 1.5 Sqmm FRLS PVC insulated multistranded copper conductor wire from the socket outlet to the fan earthing etc. complete as required.
Nos. 3
4.0 supply & Installation of unpacking, assembling, testing, & commissioning of All type of Recessed / Surface mounted Lighting Fixtures (as approved by client/architect) including all fixing hardwares complete as required S/F of 600 x 600 LED recessed mounted (LED 36 Watt 6500 K in false ceiling Helonix)
Nos. 40
5.0 supply & Installation of storing, unpacking, assembling, testing, & commissioning of All type of Recessed / Surface mounted Lighting Fixtures (as approved by client/architect) including all fixing hardwares complete as required ( LED Down Lighter 12 Watt- Helonix)
Nos. 44
6.0 installation of storing, unpacking, assembling, testing, & commissioning of All type of Recessed / Surface mounted Lighting Fixtures (as approved by client/architect) including all fixing hardwares complete as required ( LED tubeLight 20 watt Helonix)
Nos. 5
TOTAL CARRIED OVER TO SUMMARY ( G )
H) EARTHING 1.0 Earthing with copper plate electrode 600x600x3mm including
accessories & providing masonary enclosure with MS cover plate having locking arrangmnt, watering pipe and excavation in soil 6 MTRS minimum, including salt and charcoalas required including P&F 8 Guaze SWG copper wirein recessor surface for earthing as per design & detail complete. Including Supplying, laying & terminating earth connection with 8 SWG Copper wire.
No. 2
TOTAL CARRIED OVER TO SUMMARY ( H )
I) DISMANTALING 1.0 Dismantelling of existing electrical wires and fixtures and depositing
them with bank including old fans , lights , switches wires etc ( All type Electrical wire,fixture) to be deposited with banks as instructed by bank authority.
Job 1
( I )
SUPPLY & INSTALLATION FANS FIXTURES & LIGHTS
Page 61 of 72Tender for Interior Furnishing & Allied works at ZO Delhi -II, Punjab & Sind Bank / Page 59 of 70
S.NO. DESCRIPTION
AMOUNT(RS.)
A) AIR COOLED VRV UNITS
B) D.X. TYPE SPLIT A.C.UNIT:
GRAND TOTAL
1.0
1.11.1.1
1.1.2
1.1.3
1.1.4
1.1.5
1.1.6
1.1.7
1.1.8
1.1.9
1.1.10
1.1.111.1.12
1.1.13
S.No. Description Unit Qty. Rate (Rs.)Amount
(Rs.)
A) AIR COOLED VRV UNITS1.0 Outdoor Units
Supply, installation, testing and commissioning of Variable Refrigerant Flow modular type airconditioning system complete with indoor andoutdoor units, individual cordless remote with refrigerant piping,control cabling as per detail given in drawing and having followingitems:
Modular type outdoor units equipped with highly efficient inverter typescroll compressors with special precoated heat exchanger,working inboth opreation heating and cooling, low noise condenser fan housedin compact housing duly powder coated,Mounted condenser fan cowlon the discharge side of following capacitites.All Out door UnitsHaving a dedicated Isolators for Electrical Opreation.
1.1 Outdoor Unitsa) 8 HP No. 2
2 Indoor UnitsSupply, installation, testing and commissioning of following Wall
Mounted Built in type/Ceiling Mounted Ductable type units of indoor
VRV Air Conditioners with inbuilt drain pump,installing as per drawing
layout. The Vendor has to choose the indoor units of following
capacities or closest higher capacity units
2.1 Third floora) 2.5 HP (Wall mounted Type Indoor Units) Nos. 2b) 2.0 HP (Wall mounted Type Indoor Units) Nos. 6c) 1.5 HP (Wall mounted Type Indoor Units Nos 1
PREAMBLE TO BOQ:
Tendered Rates all Inclusive:Unless otherwise provided in the Bill of Quantities, the rates tendered by the Contractor for all items of the work shall be all inclusive andshall apply to all heights, lifts, leads and depths, in all positions of the building.
AIR CONDITIONING WORK BOQ OF PUNJAB & SIND BANK ZONAL OFFICE NARAINA
Rates/prices quoted in this tender shall be inclusive of cost of materials, labours, supervision, installation, testing and commissioning,materials erection, tools, plant appliances, scaffolding, sleeves, cutting, patching, excavation and backfilling, painting, storage of material,service connections, transport to site, taxes, duties, transit insurance octroi and levies, all relevant insurance charges, ESI, PF, breakage,wastage and all such expenses as may be necessary and required for the satisfactory completion of all the items of the work and finalguarantee testing and to put there in working conditions and all other requirements as called for in all the parts of these Tender Documents.
All rates quoted must be for complete items inclusive of all such accessories, fixtures and fixing arrangements, supports, nuts, bolts,hangers as are a standard part of the particular item except where specially mentioned otherwise.All rates quoted are inclusive of cutting holes and chases in walls and making good the same with cement mortar / concrete / waterproofing of appropriate mix and strength. Rates are inclusive of holes, sleeves, recesses in the concrete and masonry work as the Workproceeds except foundation work.
All rates quoted shall include marking of grills/diffusers.
Nothing extra shall be payable to Contractor on account of any of the above factors.
The client reserves the right to supply directly any of the items listed in the BOQ. For all such items, if desired by the Owner, installation,testing and commissioning shall be the responsibility of the Contractor.
Making and closing of all HVAC associated openings in walls shall form part of HVAC works. All quoted prices should be inclusive of thisaspect.Wooden frame work for mounting grills on walls shall be in the scope of HVAC works and nothing shall be paid extra for this. However,frame work for mounting grills/diffusers on false ceiling shall be provided by other agencies.
The grills/diffusers shall be measured and charged on actual area basis and 0.1m2 shall not be accepted as the minimum chargeable area.
The bidder should quote all imported equipment with price breakup in Foreign exchange and Indian Rupees.The bidder should quote as per the equipment/materials given in BOQ. Any suggested deviations can only be given as an option with
proper justification.The quoted price shall include all labelling and identification of various equipment/piping as per relevant IS colour coding. In the absence ofIS colour coding for any equipment, the labelling and identification shall be carried out as per good practice.
Page 62 of 72
Tender for Interior Furnishing & Allied works at ZO Delhi -II, Punjab & Sind Bank / Page 60 of 70
2.2 Supply, installation, tesing and commissioning of Imported Remotecontrollers (Cordless) for operation of indoor units
Nos 9
2.3 Supply, installation, tesing and commissioning of Imported fittings Y-joints Set ( 2 Nos ), distributer and headers for all Indoor units at boththe ends floors layout as per layout drawings
Sets 8
3.0 Refrigrant PipingSupply, fixing, testing and commissioning of interconnecting copper
refrigerant pipe work duly insulated (13/19 mm thick) with elastomeric
nitrile rubber type tubular insulation with Mechanically protected
between indoor & outdoor units. All piping Specially inside the room
shall be properly supported with hanger and all external piping shall
run in covered GI cably tray with UV Mechanical Protection .The Cost
of GI cable tray shall be included in the piping cost.a) 22.2mm OD RM 5b) 19.1mm OD RM 15c) 15.9mm OD RM 42d) 12.7mm OD RM 35e) 9.5mm OD RM 55f) 6.4mm OD RM 35
4.0 Transmission & Control Wiring
Providing & fixing control cum transmission wiring in mediumduty PVC Conduit between indoor and outdoor units.
a) 2C x 1.5 Sqmm Cu Cable RM 1005.0 Drain Piping
Providing & fixing rigid cPVC piping complete with fittings, supports asper specifications and pre insulated with 6mm thick closed cellelastomeric nitrile rubber tubular insulation.
a) 25 mm dia RM 50b) 32 mm dia RM 10c) 50 mm dia RM 20
TOTAL CARRIED OVER TO SUMMARY
B) D.X. TYPE SPLIT A.C.UNIT:Supply, installation, testing and commissioning of wallmounted/Ducted type split type Air-conditioning unit complete in allrespect as required, comprising of following:
a) Air cooled condensing unit consisting copper tube aluminium finned
condenser coil, air cooled by suitable size low speed fan, all mounted
in heavy gauge sheet steel enclosure with protective painting.b) Evaporating Unit consisting of copper tube aluminium finned high
transfer cooling coil, refrigerant distributor and thermostatic expansion
Valve along with blower, filters and drain pan all in heavy gauge sheet
steel metal enclosure with protective painting.c) Providing and fixing M.S. structural support for condensing unit with
vibration isolator pad in-between support and structure and vibrationisolation suspender and pads for evaporating units.
d) Complete electrical work for the above units including interconnectingcabling/wiring from the MCBs near the room units to outdoor unitscomplete in all respect including earthing.
i) 1.00 T.R. Wall mounted Split Unit. Set 1
i) 1.5.00 T.R. Wall mounted Split Unit. Set 1ii) 2.00 T.R. Ducted type Split Unit Set 1
e) Extra piping/Cabling for split airconditioning other than 10 mtsincluded in the above rates If Required
Mts 30
f) 3 step stabilizers for A.C.Make Blue Bird/Logicstar Nos. 3g)
Providing & fixing rigid cPVC 25 mm dia piping complete with fittings,supports as per specifications and pre insulated with 6mm thickclosed cell elastomeric nitrile rubber tubular insulation.
Mts 30
h)Dismantelling/Removing of existing AC Out door and indor unitelectrical AC wires and fixtures and depositing them with bankincluding All AC releted old wires,cooper/drain pipe,steblizers Etc.
Job 1
TOTAL CARRIED OVER TO SUMMARY
Page 63 of 72Tender for Interior Furnishing & Allied works at ZO Delhi -II, Punjab & Sind Bank / Page 61 of 70
S.NO. DESCRIPTIONAMOUNT(RS.)
A) FIRE ALARM SYSTEMB) FIRE FIGHTING SYSTEM
GRAND TOTAL
A) FIRE ALARM SYSTEM Unit Qty. Rate(Rs) Amounta Supplying of WIRE 2CORE 1.5mm conductor non-armoured
b.i Smoke Detector-Optical type low current draw, wide operatingvoltage 8 to 30VDC, Bi-colour LED detector status indicator.Automatic drift compensation. Tested and approved to EN54-7:2000(Amendment1). Photoelectric Smoke Detector. (Make:-Apollo/System Sensor/Edwards)
Nos 80.00
b.ii HEAT Detector-Optical type low current draw, wide operating
voltage 8 to 30VDC, Bi-colour LED detector status
indicator. Automatic drift compensation. Tested and approved
to EN54-7:2000 (Amendment1). Photoelectric Smoke Detector
(Make Apollo/System Sensor/Edwards)
Nos 10.00
b.iii Electronic Hooter, Hi-Intensive sound (80 to100 db), Tested byERTL as per IS:2189. Power I/P 100V AC or 24V DC. SoundO/P 100dB. Colour Red Speaker 4watt : (Make AgniSurkhsha/Morley)
Nos 4.00
c Supply, Installation of Manual Call Point with hammer andchain. As per IS:2189 SS Chain, Hammer & blinking. PowerI/P 24V DC, MS Sheet, 750gm., Dimensions (mm) 120x90x55.Colour - Red (Make Agni Surkhsha/Morley)
Nos 8.00
d Supplying, Installation, connection, testing and commissioningof Remote Indicators with LED Display to be attached with thedetectors as required.
Nos 8.00
e Fire Alarm Panel 4 ZONE with advanced Micro controllerbased, character LCD display Zone wise Fire, open, short LEDindicators, testing facility. Trickle & fast charging facility. Reset,alarm cancel, lamp test and control etc compatible with anymake smoke and heat detectors. (Make AgniSurkhsha/Morley) Technical: Power Supply 230 V AC, 50Hz/24VDC, Operating Voltage 24 V DC, Normal Loop Voltage 23.20V DC, E.O.L. 4K7 (Every floor 2 ZONE panel connect MainPanel In Security Guard room)
Nos 1.00
f Fire Alarm Panel 2 ZONE with advanced Micro controllerbased, character LCD display Zone wise Fire, open, short LEDindicators, testing facility. Trickle & fast charging facility. Reset,alarm cancel, lamp test and control etc compatible with anymake smoke and heat detectors. (Make AgniSurkhsha/Morley) Technical: Power Supply 230 V AC, 50Hz/24VDC, Operating Voltage 24 V DC, Normal Loop Voltage 23.20V DC, E.O.L. 4K7
Nos 4.00
g Photo Luminescent Exit Signs (Self Glowing) Green in colourof make. 300x150mm
Nos 8.00
h Providing and fixing CO2 water type fire existinguishers withsteel cylinder with a discharge valve existinguishers shall bepainted with red enamel paint. (9 Liters). As per IS:15683:2006specification, bearing ISI Mark
Nos 8.00
i Providing and fixing water CO2 gas fire existinguishers withsteel cylinder with a discharge valve and conforming to IS:940existinguishers shall be painted with rex enamel paint and fixedto wall with brackets capacity 4.5Kg per As IS:15683:2006
Nos 8.00
j Providing & fixing ABC powder type fire existinguishers ISImarked: 4kg capacity. As per IS:15683:2006 specification,bearing ISI Mark.
Nos 4.00
k Extra for Fixing of smoke detector heat detector, Manual callpoint,Electric hooter,LED display Etc and wiring in existingfalse ceiling gypsum/armstrong grid including all repairing workin existing false ceiling/walls Including plaster and paint work
Nos 106.00
BOQ OF FIRE FIGHTING WORK AT PUNJAB & SIND BANK ZONAL OFFICE NARAINA
Page 64 of 72Tender for Interior Furnishing & Allied works at ZO Delhi -II, Punjab & Sind Bank / Page 62 of 70
TOTAL FIRE ALARM SYSTEM (A)
B) FIRE FIGHTING SYSTEM1.00 Supply, Erection, Testing and commissioning of Terrace fire
pump located at terrace level capable of delivering 450 LPM30M HEAD capacity complete with adequate HP. Electricdriven mono-block type Centrifugal pump with squirrel cagemotor with bronze impeller etc (complete as per the direction of Engineer-in-charge)
Per set 1.00
2.00 Underground MS, ERW piping confirming to IS:1239 (I)
medium complete with IS:1239/ Meter fittings from parent
pipes, wrapping & coating with 4 mm factory tape (15%
overlap) including excavation in soft soil and backfilling with
soil only(complete as per the direction of Engineer-in-charge)(i) 100 NB Rmt 10.00
3.00 Above ground MS, ERW, black, medium piping conforming toIS: 1239 (I) including fittings conforming to IS:1239 (II) &painting(complete as per the direction of Engineer-in-charge)
(i) 100 NB Rmt 20.00(ii) 80 NB Rmt 20.00(iii) 50 NB Rmt 10.00(iv) 25 NB Rmt 10.00
4.00 S/F Cast Iron Wafer type Butterfly valves of PN 1.0 rating withmatching Flanges, NB & G (complete as per the direction ofEngineer-in-charge)
(i) 100 NB Each 4.005.00 S/F 2 Way Gun Metal Fire Brigade connection complete with
built in check valve and 100 NB isolation Butterfly valve(complete as per the direction of Engineer-in-charge)
Each 1.00
6.00 Small bore Hose Reel of 19 mm dia x 30 m long complete with25 NB brass gate valve and 6 mm dia nozzle (complete as perthe direction of Engineer-in-charge)
Each 4.00
7.00 Sintex water tank ( 2 Nos 5000 liters ) Ltr 10000.008.00 Miscellanneous work for water tank Job 1.00
FIRE FIGHTING SYSTEM (B)
Page 65 of 72Tender for Interior Furnishing & Allied works at ZO Delhi -II, Punjab & Sind Bank / Page 63 of 70
LOW HEIGHT STORAGE
HRD
WORKING
13'1 X 9'10"
HINDI
5' X 8'11"
LAW & RECOVERYADVANCES (LOAN)
DGM CABIN
13'-5"X 17'-8"
REST ROOM
12'-5"X8'-5"TOILET
WAITING AREA
12'-5"X9'-3"
STAIRS
DN
LIFT
STORE
17'8" X 11'
SHE TOILET
4'-9"X 6'-9"
4'-9"
GAD & INSPECTION
13' X 16'-2"
HRD
8' 9"X 6'
LO
W H
EIG
HT
S
TO
RA
GE
LOW HEIGHT STORAGE
CHIEF MANAGER CABIN
8'10" X 11'
AGM CABIN
12'-7" X 11'
L.H
.S
TO
RA
GE
L.H
.S
TO
RA
GE
L.H
.S
TO
RA
GE
L.H
.S
TO
RA
GE
L.H
.S
TO
RA
GE
L.H
.S
TO
RA
GE
L.H
.S
TO
RA
GE
L.H
.S
TO
RA
GE
L.H
.S
TO
RA
GE
L.H
.S
TO
RA
GE
L.H
.S
TO
RA
GE
RECEPTION
IT & PE
4'
TOILETTOILET
PANTRY
4'-2"X 6'-9"
ELECTRICAL PANEL
DRAWN BY:-
SCALE:DATE :
REVISION DATES
PROJECT :
DRG TITLE:
DRG.NO
PUNJAB & SIND BANK,
3RD FLOOR ZONAL
OFFICE-2
NARAINA , NEW DELHI
LAYOUT PLAN
KRISHNA SHARMA
SCALE TO FIT
PAHS/PSB/ZO OFF-2/-01
ARCHITECT:
N
NORTH
L.H
.S
TO
RA
GE
L.H
.S
TO
RA
GE
L.H
.S
TO
RA
GE
L.H
.S
TO
RA
GE
02-04-2019
03-05-2019
PAHWA ARCH-TECH SERVICES
ARCHITECTS, ENGINEERS,
INTERIOR DESIGNER, VALUER
PLOT NO-53, BLOCK-A,SECTOR-49, NOIDA
PH: 0120-4167183
Page 66 of 72Tender for Interior Furnishing & Allied works at ZO Delhi -II, Punjab & Sind Bank / Page 64 of 70
TOILET
STAIRS
DN
UP
LIFT
SHE TOILET
4'-9"X 6'-9"
4'-9"
4'
DGM CABIN
REST ROOM
AGM CABIN
STORE
CHIEF MANAGER CABIN
P A S S A G E
LVL 7'9"
LV
L 7'3"
EQ
EQ
EQ
EQ
1' 1' 1'3'4" 3'4" 3'4"
A
A'
B
B'
3'4" 3'4" 3'4"3'4" 3'4"
1'
1'
3'4"
3'4"
3'4"
3'4"
3'4" 3'4"
N
NORTH
TOILET
PANTRY
4'-2"X 6'-9"
ELECTRICAL PANEL
DRAWN BY:-
SCALE:DATE :
REVISION DATES
PROJECT :
DRG TITLE:
DRG.NO
PUNJAB & SIND BANK,
3RD FLOOR ZONAL
OFFICE-2
NARAINA , NEW DELHI
INVERTED CEILING PLAN
KRISHNA SHARMA
SCALE TO FIT
PAHS/PSB/ZO OFF-2./-02
ARCHITECT:
02-04-2019
03-05-2019PAHWA ARCH-TECH SERVICES
ARCHITECTS, ENGINEERS,
INTERIOR DESIGNER, VALUER
PLOT NO-53, BLOCK-A,SECTOR-49, NOIDA
PH: 0120-4167183
3" GREEN WIDE
BAND FOR
PASSAGE
Page 67 of 72Tender for Interior Furnishing & Allied works at ZO Delhi -II, Punjab & Sind Bank / Page 65 of 70
LOW HEIGHT STORAGE
HRD
WORKING
13'1 X 9'10"
HINDI
5' X 8'11"
LAW & RECOVERYADVANCES (LOAN)
DGM CABIN
13'-5"X 17'-8"
REST ROOM
12'-5"X8'-5"TOILET
WAITING AREA
12'-5"X9'-3"
STAIRS
DN
LIFT
STORE
17'8" X 11'
SHE TOILET
4'-9"X 6'-9"
57.00 [1447.80]
GAD & INSPECTION
13' X 16'-2"
HRD
8' 9"X 6'
LO
W H
EIG
HT
S
TO
RA
GE
LOW HEIGHT STORAGE
CHIEF MANAGER CABIN
8'10" X 11'
AGM CABIN
12'-7" X 11'
L.H
.S
TO
RA
GE
L.H
.S
TO
RA
GE
L.H
.S
TO
RA
GE
L.H
.S
TO
RA
GE
L.H
.S
TO
RA
GE
L.H
.S
TO
RA
GE
L.H
.S
TO
RA
GE
L.H
.S
TO
RA
GE
L.H
.S
TO
RA
GE
RECEPTION
IT & PE
TOILETTOILET
PANTRY
4'-2"X 6'-9"
ELECTRICAL PANEL
L.H
.S
TO
RA
GE
L.H
.S
TO
RA
GE
L.H
.S
TO
RA
GE
L.H
.S
TO
RA
GE
U1/B3
U1/B3
U1/B2
U1/B3
U1/B3
U1/B2
U1/R3
U1/R3
U1/R3
U1/R4
U1/R4
U1/R4
U1/Y3
U1/Y3
U1/Y3U1/Y4
U1/Y4
U1/Y4
U1/B4
U1/B4
U1/B4U1/B5
U1/B5
U1/B5
U1/B5
U1/Y5U1/Y5
U1/Y5
U1/Y5 U1/R5 U1/R5
U1/R5
U1/R5
P1/R3
P1/R3
P1/R3
P1/R3P1/B2
P1/B2 P1/B1 P1/B1
P1/B1
P1/B1
P1/Y2
P1/Y2
P1/Y1
P1/Y1 P1/R2
P1/R1 P1/R1
P1/R1P1/R1
P1/R2
P1/B3
P1/B3
P1/Y3
P1/B4P1/B4P1/R4
P1/R4
P1/R4P1/R4
P1/B1
P1/B2 P1/Y2
P1/Y1
P1/B4
P1/B2 PDB-1
UDB
LDB-1
D
1
2
3
4
5
6
6 AM. POWER POINT
16 AM. POWER POINT
TELEPHONE POINT
DISTRIBUTION BOX
AS/SITE
1.20
0.90
1.350
1.80
S.NO.
PARTICULAR SYMBOL FIXING LVL.
LEGEND OF ELECTRICAL FIXTURE &WIRING
7TUBE LIGHT(4'-0"/2'-0" WIDE)
2.40
CELLING FAN
U.P.S /CPC.POINT
0.90
8
0.90
BELL POINT9
2.40BRACKET LIGHT (WALL /MIRRIOR LIGHT10
0.90
11
12
13
EXHAUST FAN
2.40
SPLIT AC
SP. A/C
C-SW
A KITCHEN
B WASHING AREA
C GYESER
1.80
A ) CHIMENY
B ) RO POINT
C) ROOM
SWITCH BOARD/ 2 WAY SWITCH FOR
ROOMS WITH 1NO. 6AMP SOCKET
2.40
1.20
SWITCH BOARD ON COUNTERS WITH
3 NO. 6 AMP SOCKET
CEILING FAN
CEILING
14
CEILING LIGHT/FALSE CEILING
LED AS/SITE CONDITION
CEILING15
1500
1500
16
17
18
2100
DRAWN BY:-
SCALE:
DATE :
REVISION DATES
PROJECT : DRG TITLE:
DRG.NO
PAHWA ARCH-TECH SERVICES
ARCHITECTS, ENGINEERS,
INTERIOR DESIGNER, VALUER
PLOT NO-53, BLOCK-A,SECTOR-49, NOIDA
PH: 0120-4167183
PUNJAB & SIND BANK,
3RD FLOOR ZONAL OFFICE-2
NARAINA , NEW DELHI
PROPOSED POWER
LAYOUT
10-04-2019
PAHS/PSB/ZO OFF-2./-03
ARCHITECT:
KRISHNA SHARMA
Page 68 of 72Tender for Interior Furnishing & Allied works at ZO Delhi -II, Punjab & Sind Bank / Page 66 of 70
LOW HEIGHT STORAGE
HRD
WORKING
13'1 X 9'10"
HINDI
5' X 8'11"
LAW & RECOVERYADVANCES (LOAN)
DGM CABIN
13'-5"X 17'-8"
REST ROOM
12'-5"X8'-5"TOILET
WAITING AREA
12'-5"X9'-3"
STAIRS
DN
LIFT
STORE
17'8" X 11'
SHE TOILET
4'-9"X 6'-9"
57.00 [1447.80]
GAD & INSPECTION
13' X 16'-2"
HRD
8' 9"X 6'
LO
W H
EIG
HT
S
TO
RA
GE
LOW HEIGHT STORAGE
CHIEF MANAGER CABIN
8'10" X 11'
AGM CABIN
12'-7" X 11'
L.H
.S
TO
RA
GE
L.H
.S
TO
RA
GE
L.H
.S
TO
RA
GE
L.H
.S
TO
RA
GE
L.H
.S
TO
RA
GE
L.H
.S
TO
RA
GE
L.H
.S
TO
RA
GE
L.H
.S
TO
RA
GE
L.H
.S
TO
RA
GE
RECEPTION
IT & PE
48.00 [1219.20]
TOILETTOILET
PANTRY
4'-2"X 6'-9"
ELECTRICAL PANEL
L.H
.S
TO
RA
GE
L.H
.S
TO
RA
GE
L.H
.S
TO
RA
GE
L.H
.S
TO
RA
GE
100X50MM RACEWAY
IN FLOOR 8 WIRE
100X50MM RACEWAY
IN FLOOR 34 WIRE
200X50MM RACEWAY
IN FLOOR 68 WIRE
100X50MM RACEWAY
IN FLOOR 12 WIRE
1X25MM CONDUIT
IN FLOOR 1 WIRE
150X50MM RACEWAY
IN FLOOR 46 WIRE
150X50MM RACEWAY
IN FLOOR 52 WIRE
UDB
LDB-1
PDB-1
D
D
100X50MM RACEWAY
IN FLOOR 4 WIRE
100X50MM RACEWAY
IN FLOOR 22 WIRE
100X50MM RACEWAY
200X50MM RACEWAY
150X50MM RACEWAY
20mtr.
9mtr.
1.8mtr.
34
35
D
DRAWN BY:-
SCALE:
DATE :
REVISION DATES
PROJECT : DRG TITLE:
DRG.NO
PAHWA ARCH-TECH SERVICES
ARCHITECTS, ENGINEERS,
INTERIOR DESIGNER, VALUER
PLOT NO-53, BLOCK-A,SECTOR-49, NOIDA
PH: 0120-4167183
PUNJAB & SIND BANK,
3RD FLOOR ZONAL OFFICE-2
NARAINA , NEW DELHI
PROPOSED DATA AND
TELEPHONE RACEWAY
10-04-2019
PAHS/PSB/ZO OFF-2./-04
ARCHITECT:
KRISHNA SHARMA
Page 69 of 72Tender for Interior Furnishing & Allied works at ZO Delhi -II, Punjab & Sind Bank / Page 67 of 70
TOILET
STAIRS
DN
UP
LIFT
SHE TOILET
4'-9"X 6'-9"
DGM CABIN
REST ROOM
AGM CABIN
STORE
CHIEF MANAGER CABIN
P A S S A G E
LVL 7'9"
LV
L 7'3"
EQ
EQ
TOILET
PANTRY
4'-2"X 6'-9"
ELECTRICAL PANEL
UDB
LDB-1
E
E
E
E
EE
E
E
E
E
E
E
EE
E
E
E
E
E
E
E
E
E
U1/R1
WAITING AREA
U1/R1U1/R1
U1/R2U1/R2
U1/Y1
U1/Y2
U1/Y2
U1/Y2
U1/Y2
U1/B1
U1/B1U1/B1
U1/B1
E
E
E
E
U1/Y2
U1/Y2
U1/Y2
U1/Y1
U1/R1
U1/R1
L1/Y2
L1/Y2
L1/Y2
L1/Y2 L1/Y2
L1/Y2
L1/Y2
L1/R2
L1/R2
L1/R2
L1/R2 L1/R1
L1/R1
L1/R1
L1/R1
L1/R1
L1/Y1
L1/B1
L1/B1
L1/B1L1/B1
L1/B1
L1/B2
L1/B2
L1/B2
L1/B2
L1/B2
L1/R3
L1/R3
L1/R3
L1/Y3
L1/Y3
L1/Y3
L1/B3L1/B3
L1/B3
L1/B3L1/B3
L1/B3
L1/R2 PDB-1
1
2
3
4
5
6
6 AM. POWER POINT
16 AM. POWER POINT
TELEPHONE POINT
DISTRIBUTION BOX
AS/SITE
1.20
0.90
1.350
1.80
S.NO.
PARTICULAR SYMBOL FIXING LVL.
LEGEND OF ELECTRICAL FIXTURE &WIRING
7TUBE LIGHT(4'-0"/2'-0" WIDE) 2.40
CELLING FAN
U.P.S /CPC.POINT
0.90
8
0.90
BELL POINT9
2.40BRACKET LIGHT (WALL /MIRRIOR LIGHT10
0.90
11
12
13
EXHAUST FAN
2.40
SPLIT AC
SP. A/C
C-SW
A KITCHEN
B WASHING AREA
C GYESER
1.80
A ) CHIMENY
B ) RO POINT
C) ROOM
SWITCH BOARD/ 2 WAY SWITCH FOR
ROOMS WITH 1NO. 6AMP SOCKET
2.40
1.20
SWITCH BOARD ON COUNTERS WITH
3 NO. 6 AMP SOCKET
CEILING FAN
CEILING
14
CEILING LIGHT/FALSE CEILING
LED AS/SITE CONDITION
CEILING15
1500
1500
16
17
18
2100
DRAWN BY:-
SCALE:
DATE :
REVISION DATES
PROJECT : DRG TITLE:
DRG.NO
PAHWA ARCH-TECH SERVICES
ARCHITECTS, ENGINEERS,
INTERIOR DESIGNER, VALUER
PLOT NO-53, BLOCK-A,SECTOR-49, NOIDA
PH: 0120-4167183
PUNJAB & SIND BANK,
3RD FLOOR ZONAL OFFICE-2
NARAINA , NEW DELHI
PROPOSED LIGHTING
LAYOUT
10-04-2019
PAHS/PSB/ZO OFF-2./-05
ARCHITECT:
KRISHNA SHARMA
Page 70 of 72Tender for Interior Furnishing & Allied works at ZO Delhi -II, Punjab & Sind Bank / Page 68 of 70
LOW HEIGHT STORAGE
HRD
WORKING
13'1 X 9'10"
HINDI
5' X 8'11"
LAW & RECOVERYADVANCES (LOAN)
DGM CABIN
13'-5"X 17'-8"
REST ROOM
12'-5"X8'-5"
TOILET
TOILET
WAITING AREA
12'-5"X9'-3"
STAIRS
DN
LIFT
STORE
17'8" X 11'
SHE TOILET
4'-9"X 6'-9"
GAD & INSPECTION
13' X 16'-2"
HRD
8' 9"X 6'
LOW HEIGHT STORAGE
CHIEF MANAGER CABIN
8'10" X 11'
AGM CABIN
12'-7" X 11'
IT & PE
TOILET
PANTRY
4'-2"X 6'-9"
ELECTRICAL PANEL
A/C Not Required
DB
DATA RACK
DRAWN BY:-
SCALE:DATE :
REVISION DATES
PROJECT :
DRG TITLE:
DRG.NO
PAHWA ARCH-TECH SERVICES
ARCHITECTS, ENGINEERS,
INTERIOR DESIGNER, VALUER
PLOT NO-53, BLOCK-A,SECTOR-49, NOIDA
PH: 0120-4167183
PUNJAB & SIND BANK,
3RD FLOOR ZONAL
OFFICE-2
NARAINA , NEW DELHI
PROPOSED AC
LAYOUT PLAN
KRISHNA SHARMA
SCALE TO FIT
25-05-19
PAHS/PSB/ZO OFF-2./-07
ARCHITECT:
N
NORTH
3# 2.0 HP
HI WALL INDOOR UNIT
1.0 TR SPLIT UNIT
1.5 TR SPLIT UNIT
2.0 TR SPLIT UNIT
1.5 HP HI-WALL UNIT
8#HP OUT DOOR UNIT LOCATION AT TERRACE FLOOR
2# 2.5 HP
HI WALL INDOOR UNIT
3# 2.0 HP
HI WALL INDOOR UNIT
02-04-2019
Page 71 of 72Tender for Interior Furnishing & Allied works at ZO Delhi -II, Punjab & Sind Bank / Page 69 of 70
DRAWN BY:-
SCALE:DATE :
REVISION DATES
PROJECT :
DRG TITLE:
DRG.NO
PUNJAB & SIND BANK,
3RD FLOOR ZONAL
OFFICE-2
NARAINA , NEW DELHI
SLD DIAGRAM
SCALE TO FIT
PAHS/PSB/ZO OFF-2./-08
ARCHITECT:
02-04-2019
25.05.19PAHWA ARCH-TECH SERVICES
ARCHITECTS, ENGINEERS,
INTERIOR DESIGNER, VALUER
PLOT NO-53, BLOCK-A,SECTOR-49, NOIDA
PH: 0120-4167183
Page 72 of 72Tender for Interior Furnishing & Allied works at ZO Delhi -II, Punjab & Sind Bank / Page 70 of 70