Top Banner
Temperature coefficients and LeTID of bifacial PV modules BifiPV workshop Amsterdam – September 2019
42

Temperature coefficients and LeTID of bifacial PV modules

Mar 27, 2022

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Temperature coefficients and LeTID of bifacial PV modules

Temperature coefficients and LeTID of bifacial PV modules

BifiPV workshop Amsterdam – September 2019

Page 2: Temperature coefficients and LeTID of bifacial PV modules

Thank you for reading this whitepaper & we appreciate your feedback

2

Our whitepapers are

about sharing our

knowledge with you.

We would like to

start a dialogue on

continuous

improvement on

both sides.

We need your

feedback, so we can

make things better!

You can contact us at: [email protected] or +31 (0)15-7440161

BifiPV workshop Amsterdam – September 2019

Page 3: Temperature coefficients and LeTID of bifacial PV modules

Two topics with Yield impact for Bifacial PV

BifiPV workshop Amsterdam – September 20193

1. Temperature coefficients

2. LeTID/LID performance

Bifacial PV

Yield!

Page 4: Temperature coefficients and LeTID of bifacial PV modules

Two topics with Yield impact for Bifacial PV

BifiPV workshop Amsterdam – September 20194

1. Temperature coefficients

2. LeTID/LID performance

Bifacial PV

Yield!

Page 5: Temperature coefficients and LeTID of bifacial PV modules

Temperature coefficients are a big challenge for the PV industry

BifiPV workshop Amsterdam – September 2019

[1] MIHAYLOV, B.V. ... et al, 2014. Results of the Sophia module intercomparison part-1: STC, low irradiance conditions and temperature coefficients - C-Si technologies

Round robin between 12 leading laboratories:

+2.8%

-3.6%

-11.6%

+18.3%

Dev

iati

on

of

Pm

ax T

em

per

atu

re

Co

effi

cien

t fr

om

med

ian

Pmax accuracy constantly improving Temp coefficient accuracy has been forgotten

Typical tempco measurement uncertainties OVER 10%

5

Page 6: Temperature coefficients and LeTID of bifacial PV modules

This uncertainty gets little attention, but impact can be significant

BifiPV workshop Amsterdam – September 20196

PV power

Morning Noon Evening

Temperature

Temp. coefficient

uncertainty

In sunbelt area’s with high operating temperatures, the impact is largests

Page 7: Temperature coefficients and LeTID of bifacial PV modules

10% difference in temperature coefficient = 1.2% difference in energy yield for this PV plant location

BifiPV workshop Amsterdam – September 2019

Image adjusted from : [2] Yang Yang, YingBin Zhang…Pierre J. Verlinden, 2014. Understanding the uncertainties in the measurement of temperature coefficients of Si PV modules – PVSyst modelling of energy yield with varying temperature coefficient in Phoenix, USA climatic conditions

The following figure shows the relationship between temperature coefficient and relative energy yield for the specified location (Phoenix, USA) [2]:

7

+1.2%

-0.39%/°C-0.44%/°C

10%

A 10% difference in temperature coefficient equates to a >1% difference in energy yield

Page 8: Temperature coefficients and LeTID of bifacial PV modules

Our Goal: Reduce T.C. measurement uncertainty from

>10% to <5%, for all PV technologies

BifiPV workshop Amsterdam – September 20198

Page 9: Temperature coefficients and LeTID of bifacial PV modules

Outline

BifiPV workshop Amsterdam – September 20199

1. Temperature coefficients

2. LeTID/LID performance

Bifacial PV

Yield!

Illumination

Temperature

Procedure

Page 10: Temperature coefficients and LeTID of bifacial PV modules

Outline

BifiPV workshop Amsterdam – September 201910

1. Temperature coefficients

2. LeTID/LID performance

Bifacial PV

Yield!

Illumination

Temperature

Procedure

Page 11: Temperature coefficients and LeTID of bifacial PV modules

The single side and flip method is now regarded as most accurate

BifiPV workshop Amsterdam – September 201911

Illumination

Page 12: Temperature coefficients and LeTID of bifacial PV modules

Bifacial measurements in the temperature controlled lab flasher: very low rear irradiance

BifiPV workshop Amsterdam – September 2019

IEC requirement: ensure rear side irradiance < 3W/m2

Method: 1. Temperature box special black paint2. Black mask around module

Confirm: measure irradiance at 9 points on PV module

IEC 60904-1-2

<3W/m2

12

Illumination

Page 13: Temperature coefficients and LeTID of bifacial PV modules

Result: on all 9 points rear side irradiance < 3W/m2

BifiPV workshop Amsterdam – September 2019

Voltage measured [mV] Irradiance equivalent [W/m2]

Position on module rear 95.35 1000

P1 0.215 2.25

P2 0.192 2.01

P3 0.247 2.59

P4 0.144 1.51

P5 0.108 1.13

P6 0.157 1.65

P7 0.161 1.69

P8 0.169 1.77

P9 0.176 1.85

The temperature box is suitable for bifacial module testing according to IEC 60904-1-2 in combination with module mask

13

Illumination

Page 14: Temperature coefficients and LeTID of bifacial PV modules

Pulsewidth: HJT modules require a pulse up to 300 ms

BifiPV workshop Amsterdam – September 201914

HJT: 100-300 ms

• Every cell Voc increase of 18mV roughly doubles the carrier concentration, which causes a

doubled sweep time effect [2]

• More cells in series (e.g. 60 to 72 cells) reduces the string capacitance

• Multiflash can be applied in combination with Single Long pulse

[1] Source: Based on 5600 SLP sweep time sequence measurement of PERC module (2016)

[2] Source: Smets et al., Solar Energy: the physics and engineering of photovoltaic conversion technologies and systems (2016)

Illumination

Page 15: Temperature coefficients and LeTID of bifacial PV modules

STI/LTI

Pulsewidth: a stable single long pulse enables lowest uncertainty on high efficiency PV technologies

BifiPV workshop Amsterdam – September 201915

Illumination

Page 16: Temperature coefficients and LeTID of bifacial PV modules

Image adjusted from: Zhang et al.: 335-W World-record p-type monocrystalline module IEEE journal of photovoltaics, VOL. 6, NO. 1 (2016)

Spectrum: a wide, 300-1200 nm spectrum is critical for T.C. measurement on high efficiency cell technology

Sunlight quality

BifiPV workshop Amsterdam – September 201916

The quantum efficiency of solar cells between 400-1000nm is already at 100%

Efficiency gains PERC/Topcon/HJT

All efficiency improvements in new cells MUST occur in the 300-400nm and 1000-1200nm range

Illumination

Page 17: Temperature coefficients and LeTID of bifacial PV modules

Spectrum: when temperature increases, QE changes in 1000-1200 nm

Source: PTB Photoclass

BifiPV workshop Amsterdam – September 201917

Illumination

Page 18: Temperature coefficients and LeTID of bifacial PV modules

Spectral coverage of >99% in 300-1200 nm of EternalsunSpires 5100 & 5600 SLP Flashers enable the lowest uncertainty

BifiPV workshop Amsterdam – September 2019

0,0

0,5

1,0

1,5

2,0

2,5

300 400 500 600

AM1.5 S86-00038

60904-9Edition 3

18

Eternalsun Spire flashers have spectrum coverage starting at 300nm. This is critical for accurately measuring high efficiency technologies

Spire Flasher solar simulator

Illumination

Page 19: Temperature coefficients and LeTID of bifacial PV modules

Outline

BifiPV workshop Amsterdam – September 201919

1. Temperature coefficients

2. LeTID/LID performance

Bifacial PV

Yield!

Illumination

Temperature

Procedure

Page 20: Temperature coefficients and LeTID of bifacial PV modules

Temperature control box added to flasher:

BifiPV workshop Amsterdam – September 201920

• Heating and cooling from 15 C to 85 C• Temperature control chamber moves down to fully enclose PV module for

accurate temperature control

Temperature

Page 21: Temperature coefficients and LeTID of bifacial PV modules

Temperature control: temperature uniformity directly affects uncertainty

Any temperature difference between individual cells in the module causes an error in the coefficient

BifiPV workshop Amsterdam – September 2019

Tem

per

atu

re [°C

]

< +/- 1°C9 sensors

< +/- 1°C9 sensors

21

Temperature

Page 22: Temperature coefficients and LeTID of bifacial PV modules

Outline

BifiPV workshop Amsterdam – September 201922

1. Temperature coefficients

2. LeTID/LID performance

Bifacial PV

Yield!

Illumination

Temperature

Procedure

Page 23: Temperature coefficients and LeTID of bifacial PV modules

The “stable temperatures/dwell” method reduces uncertainty and is therefore recommended by IEC

BifiPV workshop Amsterdam – September 2019

“At each temperature level of interest, the module temperature should be stable”

Tem

per

atu

re [°C

]

9 sensors on PV module

612152016

23

Procedure

Page 24: Temperature coefficients and LeTID of bifacial PV modules

True cell temperature stability is ensured by continuously monitoring Voc

BifiPV workshop Amsterdam – September 2019

29

31

33

35

37

39

41

Vo

c [V

]

Module Voc at temperatures from 85°C to 10°C in steps of 15°C

32

32,1

32,2

32,3

32,4

32,5

32,6

32,7

32,8

32,9

33V

oc

Zoom on Voc at 70°C temperature

Stable Voc = Stable cell temperature

IV performance is determined by the true, internal solar cell temperature, which often differs from the temperature of the backside of the module that is measured.

24

Procedure

Page 25: Temperature coefficients and LeTID of bifacial PV modules

30

40

50

60

70

80

90

0:00 0:10 0:20 0:30 0:40 0:50 1:00 1:10 1:20 1:30 1:40 1:50 2:00 2:10 2:20

Tem

pe

ratu

re [

°C]

Natural cooldown method

Internal cell temperature

Backsheettemperature

∆T = 4°C

∆T = 2°C

∆T = 0.8°C

The error caused by measurement during natural cooldown can be up to 7%

BifiPV workshop Amsterdam – September 2019

Method Power T.C.

Stabilized temperatures -0.381 %/C

Hot potato -0.410 %/C

Error %Rel 7.2%

25

Procedure

Page 26: Temperature coefficients and LeTID of bifacial PV modules

Outline

BifiPV workshop Amsterdam – September 201926

1. Temperature coefficients

2. LeTID/LID performance

Bifacial PV

Yield!

Illumination

Temperature

Procedure

Page 27: Temperature coefficients and LeTID of bifacial PV modules

Bet

ter

yie

ld im

pac

tResults: significant differences between PV technologies

BifiPV workshop Amsterdam – September 2019

Source: Eternalsun Spire temperature coefficients study on 20 different PV modules, using Temperature Controlled Lab Flasher and HPLS for CdTe

27

Page 28: Temperature coefficients and LeTID of bifacial PV modules

Results: behavior is not always linear and the T.C. dependent on the range of interest

BifiPV workshop Amsterdam – September 2019

Source: Eternalsun Spire temperature coefficients study on 11 different PV modules, using Temperature Controlled Lab Flasher

28

Al-BSF p-type

Heterojunction n-type

mono PERC

195

215

235

255

275

295

315

0 10 20 30 40 50 60 70 80 90 100

Pm

ax [

W]

Temperature [°C]

Pmax vs temperature of different technologies

Page 29: Temperature coefficients and LeTID of bifacial PV modules

Results: front and rear temperature coefficients can differ significantly

BifiPV workshop Amsterdam – September 201929

Front side-0.382 %/C

Rear side-0.359 [%/C]

-25%

-20%

-15%

-10%

-5%

0%

5%

10 20 30 40 50 60 70 80 90

Pm

ax

Temperature [°C]

Front and Rear T.C.’s of Bifacial module

STC

γ - Pmax δ - FF β - Voc α - IscFront side -0.382 %/°C -0.136 %/°C -0.285 %/°C 0.028 %/°CRear side -0.359 %/°C -0.123 %/°C -0.290 %/°C 0.039 %/°CDeviation 6% 10% -2% -39%

Page 30: Temperature coefficients and LeTID of bifacial PV modules

Outline

BifiPV workshop Amsterdam – September 201931

1. Temperature coefficients

2. LeTID/LID performance

Bifacial PV

Yield!

Illumination

Temperature

Procedure

Page 31: Temperature coefficients and LeTID of bifacial PV modules

LeTID & LID: the difference

LeTID - Eternalsun Spire Whitepaper - May 2019

BOx+

FeB+

H+

[1] Chan, Catherine et al. (2017). Modulation of Carrier-Induced Defect Kinetics in Multi-Crystalline Silicon PERC Cells Through Dark Annealing. Solar RRL[2] Wenham, Stuart (2016). UNSW Advanced Hydrogenation. SPREE Alumni Event presentation. 8th December, 2016

LID LeTID

Expected cause Boron-Oxygen complexes or metal defects

Diffusing (moving) Hydrogen

Mitigation Add hydrogen Less hydrogen or temperature treatment

Timescale of effect 10-20 hours 50-500 hours

Temperatures 25-50 °C 60-90 °C

Potential extent of effect 0-3% reported c-Si modules 0-8% reported c-Si modules (commercial)

Page 32: Temperature coefficients and LeTID of bifacial PV modules

Outline

BifiPV workshop Amsterdam – September 201933

1. Temperature coefficients

2. LeTID/LID performance

Bifacial PV

Yield!

Illumination

Temperature

Procedure Setup Procedure

Page 33: Temperature coefficients and LeTID of bifacial PV modules

Setup used for LeTID study

LeTID - Eternalsun Spire Whitepaper - May 2019

• 1 sun Class AAA+ illumination• 300 to 1200 nm spectrum• 2 modules simultaneously

• 20 oC to 100 oC module temperature• In-situ IV measurements• Custom IV setpoints (e.g. Mpp)

between IV

Setup

Page 34: Temperature coefficients and LeTID of bifacial PV modules

Outline

BifiPV workshop Amsterdam – September 201935

1. Temperature coefficients

2. LeTID/LID performance

Bifacial PV

Yield!

Illumination

Temperature

Procedure Setup Procedure

Page 35: Temperature coefficients and LeTID of bifacial PV modules

Procedure: 85C, Module in Mpp between In-situ IV’s

LeTID - Eternalsun Spire Whitepaper - May 2019

-5,0

-4,5

-4,0

-3,5

-3,0

-2,5

-2,0

-1,5

-1,0

-0,5

0,0

0 30 60 90 120 150 180 210 240

Rel

ativ

e P

max

dev

iati

on

[%

]

Lightsoaking time at 85C [h]

degradation regeneration

Procedure

Page 36: Temperature coefficients and LeTID of bifacial PV modules

-5,0

-4,5

-4,0

-3,5

-3,0

-2,5

-2,0

-1,5

-1,0

-0,5

0,0

0 30 60 90 120 150 180 210 240

Rel

ativ

e P

max

dev

iati

on

[%

]

Lightsoaking time at 85C [h]

degradation regeneration

LeTID: visibility in EL imaging

LeTID - Eternalsun Spire Whitepaper - May 2019

Procedure

Page 37: Temperature coefficients and LeTID of bifacial PV modules

Alternative procedure: current soaking and interval IV flashing

LeTID - Eternalsun Spire Whitepaper - May 2019

-5,0

-4,5

-4,0

-3,5

-3,0

-2,5

-2,0

-1,5

-1,0

-0,5

0,0

0 30 60 90 120 150 180 210 240

Rel

ativ

e P

max

dev

iati

on

[%

]

Lightsoaking time [h]

Flasher IV measurements

Exposure time [h]

Degradation

Flasher IV Reproducibility

Procedure

Estimated

Page 38: Temperature coefficients and LeTID of bifacial PV modules

Procedure: Benefit of in-situ IV vs current soaking and flashing

LeTID - Eternalsun Spire Whitepaper - May 2019

-5,0

-4,5

-4,0

-3,5

-3,0

-2,5

-2,0

-1,5

-1,0

-0,5

0,0

0 30 60 90 120 150 180 210 240

Rel

ativ

e P

max

dev

iati

on

[%

]

In-situ IV measurements

True values

Flasher IV measurements

Exposure time [h]

Degradation

Procedure

Estimated

Page 39: Temperature coefficients and LeTID of bifacial PV modules

Outline

BifiPV workshop Amsterdam – September 201940

1. Temperature coefficients

2. LeTID/LID performance

Bifacial PV

Yield!

Illumination

Temperature

Procedure Setup Procedure

Page 40: Temperature coefficients and LeTID of bifacial PV modules

LeTID Results

BifiPV workshop Amsterdam – September 201941

-6,0%

-5,0%

-4,0%

-3,0%

-2,0%

-1,0%

0,0%

1,0%

2,0%

0 20 40 60 80 100 120 140 160 180 200 220 240

Rel

ativ

e P

max

dev

iati

on

[%

]

Lightsoaking time [h]

LeTID test at 85C, Mpp between in-situ IV’s

Heterojunction, N-type (manufacturer A)

Mono PERC, N & P-type (manufacturers B&C)

Poly PERC, P-type(manufacturers D&E)

Source: Eternalsun Spire LeTID study on 14 different PV modules, using High Performance Light Soaker

Page 41: Temperature coefficients and LeTID of bifacial PV modules

LeTID Results

BifiPV workshop Amsterdam – September 201942

-6,0%

-5,0%

-4,0%

-3,0%

-2,0%

-1,0%

0,0%

1,0%

2,0%

0 20 40 60 80 100 120 140 160 180 200 220 240

Rel

ativ

e P

max

dev

iati

on

[%

]

Lightsoaking time [h]

LeTID test at 85C, Mpp between in-situ IV’s

Heterojunction, N-type (manufacturer A)

Mono PERC, N & P-type (manufacturers B&C)

Poly PERC, P-type(manufacturers D&E)

Source: Eternalsun Spire LeTID study on 14 different PV modules, using High Performance Light Soaker

Bifacial Technologies

Page 42: Temperature coefficients and LeTID of bifacial PV modules

Thank you!

BifiPV workshop Amsterdam – September 2019

Steady State AAA+ Sun Simulators

Integrated in Climate Chambers

Providing high-end solar testing application knowledge, technology & services

A+A+A+ 270ms Sun Simulators

Advanced Temperature control

IV and EL test services at

Rotterdam harbour warehouse

43