Description & Features Without thermowell Thermowell with threaded process connection Thermowell with flanged process connection Thermowell with sanitary type process connection Please refer to catalogues of thermowells Order Information Series/ Dial Size/ Case Materials/ Wetted Parts/ Configuration/ Connection Size/ Thread/ Range/ Option NO. 1/5 www.winters.com / www.wintersasia.com Series RTD (Resistance Temperature Detector) TEJ RTD (Resistance Temperature Detector) TEJ Caution: reduced ambient temperature when using transmitters Aluminium box and temperature transmitter can be installed in Explosion-proof stainless steel box (EEx d IIC T6) Explosion-proof 304SS box (EEx d IIC T6) Field diaplay LED/LCD Explosion-proof temperature transmitters Explosion-proof aluminium box (EEx d IIC T5) JIS standard Non Intrinsic safety type temperature transmitter 2-wire transmitter with HART protocol Isolated smart temperature transmitter - Thermocouple input Isolated smart temperature transmitter - RTD / input Thermocouple ® Intrinsic safety type temperature transmitter 2-wire transmitter with HART protocol ® Intrinsic safety type temperature transmitter Profibus PA/Foundation Fieldbus bus protocol Code: JT Code:ASX Code:SX Code:TTID Code:BSX Explosion proof (EEx d IIC T5, ) EEx d IIC T6
5
Embed
TEJ Series RTD (Resistance Temperature Detector)wintersasia.com/XlUploadImages/2014527113122.pdf · TEJ Series RTD (Resistance Temperature Detector) / NO. 5/5 RTD (Resistance Temperature
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Description & Features
Without thermowellThermowell with threaded process connectionThermowell with flanged process connectionThermowell with sanitary type process connectionPlease refer to catalogues of thermowells
Order InformationSeries/ Dial Size/ Case Materials/ Wetted Parts/ Configuration/ Connection Size/ Thread/ Range/ Option
NO. 1/5www.winters.com / www.wintersasia.com
Series RTD (Resistance Temperature Detector)TEJ
RTD (Resistance Temperature Detector) TEJ
Caution: reduced ambient temperature when using transmitters
Aluminium box and temperature transmitter can be installed in
Explosion-proof stainless steel box (EEx d IIC T6)
Explosion-proof 304SS box (EEx d IIC T6)
Field diaplay LED/LCD Explosion-proof temperature transmitters
Explosion-proof aluminium box (EEx d IIC T5)
JIS standard
Non Intrinsic safety type temperature transmitter
2-wire transmitter with HART protocol
Isolated smart temperature transmitter - Thermocouple input
Isolated smart temperature transmitter - RTD / inputThermocouple
®
Intrinsic safety type temperature transmitter
2-wire transmitter with HART protocol®
Intrinsic safety type temperature transmitter Profibus PA/Foundation
Fieldbus bus protocol
Code: JT Code:ASXCode:SX Code:TTIDCode:BSX
Explosion proof (EEx d IIC T5, )EEx d IIC T6
Series RTD (Resistance Temperature Detector)TEJ
NO. 2/5www.winters.com / www.wintersasia.com
RTD (Resistance Temperature Detector) TEJ
Series RTD (Resistance Temperature Detector)TEJ
Dimensions (Unit:mm)
NO. 3/5www.winters.com / www.wintersasia.com
RTD (Resistance Temperature Detector) TEJ
EL: Insertion Length
TL: Extension Length
G: Process Connection
D: Outside Diameter of Protection Tube
EL: Insertion Length
TL: Extension Length
D: Outside Diameter of Protection Tube
RTD (Resistance Temperature Detector) with Thread Connection
RTD (Resistance Temperature Detector) with Flanged Connection
Series RTD (Resistance Temperature Detector)TEJ
NO. 4/5www.winters.com / www.wintersasia.com
RTD (Resistance Temperature Detector) TEJ
Terminal Head Form
2.Operating Temperature in ℃
3.Measuring Insert
13
Tolerance Class to EN 60 751
201
202
203
142322
M2
M3
1
2
3
4.
TEJ Series Ordering Code
Code Specifications
-50...+400℃ (standard)-50...+600℃
-200...+600℃
1xPt100 in 3-wire circuit1xPt100 in 4-wire circuit
2xPt100 in 3-wire circuit
2xPt100 in 2-wire circuit
1xPt1000 in 2-wire circuit1xPt1000 in 3-wire circuit
Class B (standard)Class A
1/3DIN
NO. 3/4www.winters.com / www.wintersasia.com
Thermocouples TCJ
1. JT
BSX
Aluminium box and temperature transmitter can be installed in JIS standard
Explosion-proof stainless steel box (EEx d IIC T6)
Explosion-proof 304SS box (EEx d IIC T6)
Field diaplay LED/LCD Explosion-proof temperature transmitters
SX
TTID
ASX Explosion-proof aluminium box (EEx d IIC T5)
Code: JT Code: SX Code: BSXCode: ASX Code: TTID
5.Extenson length TL in mm
00
5075
100
150
ZZZ Special request
6.Protection tube outside diameter D in mm
06
08
09
10
11
1216
ZZ Special request
Explosion proof (EEx d IIC T5, )EEx d IIC T6
Series RTD (Resistance Temperature Detector)TEJ
NO. 5/5www.winters.com / www.wintersasia.com
RTD (Resistance Temperature Detector) TEJ
B
T
10.
G
Thread Type
9.Connection Size
S
E
M
Z
N
0
4
3
2
Z
0
SP
ZZ
11.
FP
Process Connection
TP
00
13.Option
SR
8.Insertion Length EL in mm
050
075
100
160220
250
280400ZZZ Special request
None
Special request
Special request
Special request
None
Without thermowellThermowell with threaded process connectionThermowell with flanged process connectionThermowell with sanitary type process connection
Interchangeable inserts
TEJ Series Ordering Code
Code Specifications
7.Protection tube material
T
SL
Z Special request
304SS316SS
316LSS
12.Transmitter
TTHA
WO Without transmitter
Intrinsic safety type temperature transmitter 2-wire transmitter with HART protocol
TTAF Intrinsic safety type temperature transmitter Profibus PA/Foundation Fieldbus bus protocol
TTYR RTD input two-wire temperature ( )transmitter Isolated
®TTHN Non intrinsic safety type temperature transmitter 2-wire transmitter with HART protocol®
ZZ Special requestTTRC RTD/Thermocouple input two-wire temperature (USB interface, )transmitter Isolated