Top Banner
Features Technor’s EEx p pressurized systems are designed and purpose built according to each client’s requirements. Our ability to deliver “Custom Made”, is one of the main reasons for choosing a Technor solution. Technor deliver turnkey solutions with enclosures made in acid resistant stainless steel, SS316, all certified by DNV. Main advantages by choosing TNCNP: Large flexibility regarding design of panels. Tailor solutions according to clients request. Excellent solution by use of electrical components: With great heat dissipation. With large physical measures and weight. High operational reliability and cost efficiency, reduced lifetime maintenance costs. ATEX approved. Options: Windows (max.size: 0,3m2 for each window) Mounting plates Lifting lugs Socket Transit frames Certified components mounted in door or walls One or several doors Technor as, Dusavikv. 39, P.O. Box 658, NO-4003 Stavanger, Norway Phone: +47 51844100, Fax: +47 51844101, E-mail: [email protected]. www.technor.no TNCNP / ELB F-351 EEx p solutions
6
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
  • FeaturesTechnors EEx p pressurized systems are designed and purpose built according to each clients requirements. Our ability to deliver Custom Made, is one of the main reasons for choosing a Technor solution. Technor deliver turnkey solutions with enclosures made in acid resistant stainless steel, SS316, all certified by DNV.

    Main advantages by choosing TNCNP:

    Large flexibility regarding design of panels.

    Tailor solutions according to clients request.

    Excellent solution by use of electrical components:

    With great heat dissipation.

    With large physical measures and weight.

    High operational reliability and cost efficiency, reduced lifetime maintenance costs.

    ATEX approved.

    Options:

    Windows (max.size: 0,3m2 for each window)

    Mounting plates

    Lifting lugs

    Socket

    Transit frames

    Certified components mounted in door or walls

    One or several doors

    Technor as, Dusavikv. 39, P.O. Box 658, NO-4003 Stavanger, Norway

    Phone: +47 51844100, Fax: +47 51844101, E-mail: [email protected]. www.technor.no

    TNCNP / ELB F-351

    EEx p solutions

  • ApplicationsFor use of standard (non-ex) electrical components in zone 1 and 2.

    Monitoring systems

    Control systems

    Computers (both traditional and LCD monitors)

    Driller consoles

    Large motor starters

    General Specifications

    EEx p solutions

    Material Acid resistant stainless steel SS316

    IP Rating IP66/IP67

    Temperature -40C - +60C

    ATEX approvals DNV-2003-OSL-ATEX-0028 (complete enclosure) DNV-2003-OSL-ATEX-0027U (empty enclosure)

    Standards EN50014, EN50016 IEC60079-0, IEC60079-2

    Ex-Code EEx p II II 2 G

    Lid/Door gasket Neoprene (temp. -40C to +100C) Silicone (temp. -40C to +200C)

    Surface treatment Acidized as standard Electro polished as an option

    Earthing Internal earth bar/bracket External earth bracket

  • EEx d, IIC / IIB Explosion proof enclosures

    EEx p control unit F-351

    EEx p solutions

    Specification for EEx p control unit F-351Material GRP, epoxy resin, black

    IP Rating IP65

    Temperature Operating: -300C - +600C, without condensation

    ATEX approvals TV 02ATEX1801

    Standards EN50014, EN50016, EN50018, EN50019, EN50020, EN50028, EN954-1

    Ex-Code II 2 G EEx e m ia [p] [ia] IIC T4

    Dimensions HxWxD: 122mm x 122mm x 90mm

    Electrical specifications:Current consumption 30mA at 230VAC / 60mA at 115VAC/

    300mA at 24VAC / 200mA at 24VDC

    Mains Voltage 12VDC, 24VDC, 24VAC, 115VAC, 230VAC, 4862Hz

    Contact load AC: U = 250VAC, I =12,0A / cos j = 1

    Terminals 6-7 AC:U = 230VAC, I = 3A

    Terminals 9-10 DC:U = 230VDC, I = 3A

    4xEEx cable glands 2xM16 for cable d = 4,5 10mm, 2xM20 for cable d = 7-13mm

    DisplayPurge time 0-99min.realtime display (only in time

    control mode)

    LCD-Display high reflectivePressure range 0-25 mbar, resolution: 0,1mbar

    Menu and status Text displays: 3 lines x 12 characters

    Errors Via display and acoustic (with remote unit F-411)

    Viewing windowMounted in cover of unit To read the LCD display under operation

    without removing the cover of the controller

    Material Polyacryl, highly visible, diameter 58mm

    MountingPosition of mounting on cabinet

    Without any limitations

    Ambient temperature during storage/transport

    -350C to + 700C, without condensation

    PneumaticMeasure Range 0-25 mbar

    Flow 6,5l/min (0,1 l/sec) 330,0l/min (5,5l/sec)

    Relief valve Patent. Completely maintenance-free air outlet with integrated ex-proofed particle barrier

    Security ClassDuo-tec Technology Fail safe, meets AK4

    (according to EN945-1, cat.3)

    ParameterizePatented wheel shuttle

    Patented wheel-shuttle technology for quick and easy adjusting and configuration

    Configuration With menu on LCD display, different languages selectable: German, English

  • Options for control unit F-351.P / F351.F (for high flow and external air outlet)

    PneumaticFlow Unlimited

    Relief valve N/A, only use together with separate air outlet with integrated spark/particle barrier

    MountingPosition for mounting on cabinet, version F-351.P

    On the cabinet wall or elsewhere in the same room as the cabinet (no limitations to position)

    Position for mounting on cabinet, version F351.F

    On the cabinet wall (no limitations to position)

    EEx p solutions

  • TNCD-TNBCD

    Air processing unit

    General specification ELB500001/500002/500005Material GRP, epoxy resin, black/brass

    Temperature Operating: -300C - +600C, Storage: -400C - +700C, without condensationOther temperature ranges upon request

    ATEX approvals PTB00ATEX2129X

    Standards EN50014, EN50019, EN50028

    Ex-Code II 2 G EEx e m II T4

    Dimensions HxWxD: 205mm x 185mm x 90mm

    Electrical specifications:Current consumption

    30mA at 230VAC / 60mA at 115V / 300mA at 24V

    Mains Voltage 24VAC/DC, 115VAC/DC, 230VAC/DC, 4862Hz

    Limit power 9W

    EEx cable glands 1xM20 for cable d = 6,0-13,0mm

    PneumaticPressure 0,5-10bar

    Flow 1500l/min. Higher flow rates upon request

    Connection 3/8 NPT / 10mm tube fitting. Other connections upon request

    AdjustmentPurge flow External adjustment screw located in nozzle

    Maintenance flow External adjustment screw located at valve body

    MountingPosition of mounting in cabinet

    Without any limitations (inside cabinet)

    EEx p solutions

  • NO

    VEM

    BER

    200

    5 V

    ERSI

    ON

    1.0

    A

    RTD

    IREC

    TOR.

    NO

    SP

    ESIA

    LTRY

    KK

    Technor as, Dusavikv. 39, P.O. Box 658, NO-4003 Stavanger, Norway

    Phone: +47 51844100, Fax: +47 51844101, E-mail: [email protected]. www.technor.no

    Hazardous area information & terminology ATEX Directive

    The ATEX Directive, derived from the French ATmosphres EXplosibles and formally known as 94/9/EC, contains the ESR (Essential Safety Requirements) to which electrical equipment and protective systems used within potentially explosive atmospheres must conform.

    The new ATEX Directive currently in place within the European Union was made mandatory on 1st July 2003. Primarily intended for manufacturers of hazardous area equipment for use in the presence of flammable gases, vapours, fumes or dusts, the new directive requires a quality management system to be implemented.

    Procedures for the design, manufacture and verification of products are to be approved by a notified body (i.e. DNV, NEMKO, etc.) and all equipment conforming to the new directive will feature CE and Ex Marking.

    Zone Classification with the presence of GASZone 1(Category 2)

    An area in which explosive gas is likely to be present during normal operation of the plant.

    Zone 2(Category 3)

    An area in which explosive gas is not continuously present, but may exist for a short period of time.

    Applicable EX protectionEEx p ProtectionThe ingress of the surrounding atmosphere into the housing of electrical equipment is prevented by maintaining an ignition shield gas (air or a different suitable gas) inside it at a pressure above atmospheric pressure. The overpressure is maintained with continuous flushing of the protective gas.

    EEx p solutions