Top Banner
Technische Universität München Status report on SADC feature extraction
15

Technische Universität München Status report on SADC feature extraction.

Mar 28, 2015

Download

Documents

Mia Robinson
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Technische Universität München Status report on SADC feature extraction.

Technische Universität München

Status report on

SADC feature extraction

Page 2: Technische Universität München Status report on SADC feature extraction.

Technische Universität München

Outline

• Feature extraction fitting pulses– General idea– Parameter sets– Implementation

• AC noise suppression• Performance (comp. to std. alg.)

– Energy spectrum for e- calibration

– “0” mass spectrum

• Conclusion

Page 3: Technische Universität München Status report on SADC feature extraction.

Technische Universität München

Feature extraction using functional parameterization

• Describe pulses by analytic function (Silicon, J. Friedrich)

• Fix function parameters (calibration)• Fit/Calculation of time and amplitude

Page 4: Technische Universität München Status report on SADC feature extraction.

Technische Universität München

Typical pulse and its description

Page 5: Technische Universität München Status report on SADC feature extraction.

Technische Universität München

Result of fit (first parameter)

Using three parameter sets for ECAL02

Parameter sets depend on shaper not on cell type!!

Page 6: Technische Universität München Status report on SADC feature extraction.

Technische Universität München

Signals on two different channels

Analytic calculation of function variables due to large amplitude error not desirable

Page 7: Technische Universität München Status report on SADC feature extraction.

Technische Universität München

AC coupling

Page 8: Technische Universität München Status report on SADC feature extraction.

Technische Universität München

AC Coupling suppression (ACS)

• AC coupling signals have amplitude independent length

• Remove all signals with a half-width ≤ 5

• Problems for small signal introduce threshold to apply cut

Page 9: Technische Universität München Status report on SADC feature extraction.

Technische Universität München

40 GeV e- Beam – ECAL calibration(std: green, pf: red)

Page 10: Technische Universität München Status report on SADC feature extraction.

Technische Universität München

40 GeV e- Beam – ECAL calibration(std: green, pf: red)

Page 11: Technische Universität München Status report on SADC feature extraction.

Technische Universität München

40 GeV e- Beam – ECAL calibration(std: green, pf+acs: blue)

Page 12: Technische Universität München Status report on SADC feature extraction.

Technische Universität München

M(0) (PulseFit & AC suppresion) VS std. FE

• slightly improved energy resolution (~ 4%)

• slightly improved signal to bg ratio ~ (0.2%)

• reduced signal integral (~ 8%)

Page 13: Technische Universität München Status report on SADC feature extraction.

Technische Universität München

Deeper analysis:

Feature of shower reconstruction (“instable” against small changes )

M(0) PulseFit VS std. FE

• increased signal integral (~ 4%)

• decreased energy resolution (~ 50%)

• decreased signal to bg ratio (~ 20%)

Page 14: Technische Universität München Status report on SADC feature extraction.

Technische Universität München

Conclusion

• Alternative method for feature extraction available• Electron beam performance (without calibration

adaption) promising• Reconstruction problems for 0 observed

Improvement by adaption of shower reconstruction possible?

• Increased CPU usage (for physics runs 20% of total runtime)

• Fine tuning needed (dep. on shower reconstruction) For the moment std. reconstruction is the preferable

option!!!

Page 15: Technische Universität München Status report on SADC feature extraction.

Technische Universität München

Thank you.