TVR II SPECS Indoor Electrical Data 23 Technical Service Manual TVR II Systems Heat Pump – 220~240/60/3 October 2012
13
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Technical Service Manual TVR II

TVR II SPECS

Indoor Electrical Data 23

Technical Service Manual

TVR II Systems

Heat Pump – 220~240/60/3

October 2012

Page 2: Technical Service Manual TVR II

TVR II SPECS

Indoor Electrical Data 24

TVR II Indoor Units

1 Electric Data .......................................................................

Page 3: Technical Service Manual TVR II

TVR II SPECS

Indoor Electrical Data 25

One-way Cassette Type

Electrical Data

Model

Indoor Unit Power Supply IFM

Hz Voltage Min. Max. MCA MFA KW FLA

4TVE0009B1 60 220-240V 198V 254V 0.2675 5 0.020 0.214

4TVE0012B1 60 220-240V 198V 254V 0.2675 5 0.020 0.214

4TVE0015B1 60 220-240V 198V 254V 0.5025 5 0.055 0.402

4TVE0018B1 60 220-240V 198V 254V 0.5025 5 0.055 0.402

4TVE0024B1 60 220-240V 198V 254V 0.5025 5 0.055 0.402

Remark:

MCA: Min. Current Amps. (A)

MFA: Max. Fuse Amps. (A)

KW: Fan Motor Rated Output (kW)

FLA: Full Load Amps. (A)

IFM: Indoor Fan Motor

Page 4: Technical Service Manual TVR II

TVR II SPECS

Indoor Electrical Data 26

Four-way Cassette Type

Electrical Data

Model

Indoor Unit Power Supply IFM

Hz Voltage Min. Max. MCA MFA kW FLA

4TVC0009B1 60Hz 220-240V 198V 254V 0.5 15A 0.06 0.38

4TVC0012B1 60Hz 220-240V 198V 254V 0.5 15A 0.06 0.38

4TVC0015B1 60Hz 220-240V 198V 254V 0.5 15A 0.06 0.38

4TVC0018B1 60Hz 220-240V 198V 254V 0.5 15A 0.06 0.38

4TVC0024B1 60Hz 220-240V 198V 254V 0.65 15A 0.080 0.5

4TVC0027B1 60Hz 220-240V 198V 254V 0.65 15A 0.080 0.5

4TVC0030B1 60Hz 220-240V 198V 254V 0.85 15A 0.09 0.67

4TVC0034B1 60Hz 220-240V 198V 254V 0.85 15A 0.09 0.67

4TVC0038B1 60Hz 220-240V 198V 254V 0.85 15A 0.09 0.67

4TVC0048B1 60Hz 220-240V 198V 254V 0.85 15A 0.09 0.67

Remark:

MCA: Min. Current Amps. (A)

MFA: Max. Fuse Amps. (A)

kW: Fan Motor Rated Output (kW)

FLA: Full Load Amps. (A)

IFM: Indoor Fan Motor

Page 5: Technical Service Manual TVR II

TVR II SPECS

Indoor Electrical Data 27

Compact Four-way Cassette Type

Electrical Data

Model Indoor Unit Power Supply IFM

Hz Voltage Min. Max. MFA kW FLA

4TVB0007B6 60 220-240 198 254 15 0.039 0.175

4TVB0009B6 60 220-240 198 254 15 0.039 0.175

4TVB0012B6 60 220-240 198 254 15 0.049 0.21

4TVB0015B6 60 220-240 198 254 15 0.049 0.21

Remark:

MCA: Min. Current Amps. (A)

MFA: Max. Fuse Amps. (A)

kW: Fan Motor Rated Output (kW)

FLA: Full Load Amps. (A)

IFM: Indoor Fan Motor

Page 6: Technical Service Manual TVR II

TVR II SPECS

Indoor Electrical Data 28

Two-way Cassette Type

Electric Data

Model

Indoor Unit Power Supply IFM

Hz Voltage Min. Max. MCA MFA KW FLA

4TWG0007B1 60 220-240V 198V 254V 0.384 15A 0.076 0.33

4TWG0009B1 60 220-240V 198V 254V 0.384 15A 0.076 0.33

4TWG0012B1 60 220-240V 198V 254V 0.42 15A 0.081 0.36

4TWG0015B1 60 220-240V 198V 254V 0.62 15A 0.112 0.5

4TWG0018B1 60 220-240V 198V 254V 0.66 15A 0.131 0.58

4TWG0024B1 60 220-240V 198V 254V 1.07 15A 0.202 0.87

Remark:

MCA: Min. Current Amps. (A)

MFA: Max. Fuse Amps. (A)

KW: Fan Motor Rated Output (kW)

FLA: Full Load Amps. (A)

IFM: Indoor Fan Motor

Page 7: Technical Service Manual TVR II

TVR II SPECS

Indoor Electrical Data 29

Low Static Pressure Duct

Electrical Data

Model

Indoor Unit Power Supply IFM

Hz Voltage Min. Max. MCA MFA KW FLA

4TVL0007B1 60 230 207 253 0.175 15 0.03 0.14

4TVL0009B1 60 230 207 253 0.187 15 0.032 0.15

4TVL0012B1 60 230 207 253 0.187 15 0.032 0.15

4TVL0015B1 60 230 207 253 0.35 15 0.053 0.28

4TVL0018B1 60 230 207 253 0.35 15 0.053 0.28

Remark:

MCA: Min. Current Amps. (A)

MFA: Max. Fuse Amps. (A)

KW: Fan Motor Rated Output (kW)

FLA: Full Load Amps. (A)

IFM:Indoor Fan Motor

Page 8: Technical Service Manual TVR II

TVR II SPECS

Indoor Electrical Data 30

Medium Pressure Concealed units

Electrical Data

Model

Indoor Unit Power Supply IFM

Hz Voltage Min. Max. MCA MFA KW FLA

4TVD0007B1 60 208-230 207 253 0.35 15 0.027 0.275

4TVD0009B1 60 208-230 207 253 0.35 15 0.027 0.275

4TVD0012B1 60 208-230 207 253 0.35 15 0.027 0.33

4TVD0015B1 60 208-230 207 253 0.64 15 0.109 0.51

4TVD0018B1 60 208-230 207 253 0.64 15 0.109 0.51

4TVD0024B1 60 208-230 207 253 1.04 15 0.183 0.83

4TVD0027B1 60 208-230 207 253 1.39 15 0.225 1.11

4TVD0030B1 60 208-230 207 253 1.39 15 0.225 1.11

4TVD0038B1 60 208-230 207 253 2.35 15 0.41 1.55

4TVD0048B1 60 208-230 207 253 1.99 15 0.345 1.59

Electrical Data

Remark:

MCA: Min. Current Amps. (A)

MFA: Max. Fuse Amps. (A)

KW: Fan Motor Rated Output (kW)

FLA: Full Load Amps. (A)

IFM:Indoor Fan Motor

Page 9: Technical Service Manual TVR II

TVR II SPECS

Indoor Electrical Data 31

High static pressure duct unit

Electrical Data

Model

Indoor Unit Power Supply IFM

Hz Voltage Min. Max. MCA MFA KW FLA

4TVA0024B1 60 208-230V 207V 254V 1.23 5 0.1 1.17

4TVA0027B1 60 208-230V 207V 254V 1.23 5 0.1 1.17

4TVA0030B1 60 208-230V 207V 254V 1.87 5 0.16 1.71

4TVA0038B1 60 208-230V 207V 254V 2.3 5 0.2 2.18

4TVA0048B1 60 208-230V 207V 254V 2.85 5 0.3 2.56

4TVA0055B1 60 208-230V 207V 254V 4.77 6 0.4 3.52

Remark:

MCA: Min. Current Amps. (A)

MFA: Max. Fuse Amps. (A)

KW: Fan Motor Rated Output (kW)

FLA: Full Load Amps. (A)

IFM:Indoor Fan Motor

Page 10: Technical Service Manual TVR II

TVR II SPECS

Indoor Electrical Data 32

Wall Mounted Type

ELECTRICAL DATA

Remark

MCA: Min. Current Amps. (A)

MFA: Max. Fuse Amps. (A)

KW: Fan Motor Rated Output (kW)

FLA: Full Load Amps. (A)

IFM:Indoor Fan Motor

Model

Indoor Unit Power Supply IFM

Hz Voltage Min. Max. MCA MFA KW FLA

4TVW0007B1

(without electric heater) 60 220-240V 198 254 0.3 15 0.013 0.225

4TVW0009B1

(without electric heater) 60 220-240V 198 254 0.3 15 0.013 0.225

4TVW0012B1

(without electric heater) 60 220-240V 198 254 0.3 15 0.013 0.225

4TVW0015B1

(without electric heater) 60 220-240V 198 254 0.3 15 0.028 0.24

4TVW0018B1

(without electric heater) 60 220-240V 198 254 0.3 15 0.028 0.24

4TVW0007B1

(with electric heater) 60 220-240V 198 254 3.6 15 0.013 0.225

4TVW0009B1

(with electric heater) 60 220-240V 198 254

3.6 15 0.013 0.225

4TVW0012B1

(with electric heater) 60 220-240V 198 254

3.6 15 0.013 0.225

4TVW0015B1

(with electric heater) 60 220-240V 198 254 4.3 15 0.028 0.24

4TVW0018B1

(with electric heater) 60 220-240V 198 254 4.3 15 0.028 0.24

Page 11: Technical Service Manual TVR II

TVR II SPECS

Indoor Electrical Data 33

Ceiling & Floor Type

ELECTRICAL DATA

Remark:

MCA: Min. CircuitAmps. (A)

MFA: Max. Fuse Amps. (A)

KW: Fan Motor Rated Output (kW)

FLA: Full Load Amps. (A)

IFM:Indoor Fan Motor

Model

Indoor Unit Power Supply IFM

Hz Voltage Min. Max. MCA MFA KW FLA

4TVX0012B1 60 220-240V 198 254 0.21 5 0.025 0.15

4TVX0015B1 60 220-240V 198 254 0.64 5 0.055 0.57

4TVX0018B1 60 220-240V 198 254 0.64 5 0.055 0.57

4TVX0024B1 60 220-240V 198 254 0.64 5 0.055 0.57

4TVX0027B1 60 220-240V 198 254 0.8 5 0.08 0.63

4TVX0030B1 60 220-240V 198 254 0.8 5 0.08 0.63

4TVX0038B1 60 220-240V 198 254 1.05 5 0.059*2 0.39*2

4TVX0048B1 60 220-240V 198 254 1.05 5 0.059*2 0.39*2

4TVX0055B1 60 220-240V 198 254 2.2 5 0.09*2 0.39*2

Page 12: Technical Service Manual TVR II

TVR II Indoor units Specs Selection Procedure

Fresh air processing unit

Model

Indoor Unit Power Supply IFM

Hz Voltage Min. Max. MCA MFA KW FLA

4TVF0042B1 60 220-240V 198V 254V 2.4 5 0.3 2

4TVF0048B1 60 220-240V 198V 254V 2.4 5 0.3 2

4TVF0068B1 60 220-240V 198V 254V 5.3 10 0.25(×2) 4.8

4TVF0085B1 60 220-240V 198V 254V 5.6 10 0.25(×2) 4.8

4TVF0095B1 60 220-240V 198V 254V 5.6 10 0.25(×2) 4.8

Remark:

MCA: Min. Current Amps. (A)

MFA: Max. Fuse Amps. (A)

KW: Fan Motor Rated Output (KW)

FLA: Full Load Amps. (A)

IFM: Indoor Fan Motor

Page 13: Technical Service Manual TVR II

TVR II Indoor units Specs Selection Procedure