web: www.panduit.com e-mail: [email protected] phone: 800-777-3300 page 1 TECHNICAL REFERENCE TR113 *MTP is a registered trademark of US Conec Ltd. Panduit Link Scenarios Method A Guidelines for Typical Multimode Duplex Signals 10G Ethernet and Fibre Channel Applications (OM3 Fiber with Standard Loss) Method A Link with OM3 Fiber and Standard Loss - 2 Harness Design Method A Link with OM3 Fiber and Standard Loss – 2 Harness Design Component Description Part Number Description Standard Insertion Loss Quantity Polarity Total Link Loss Harness (End 1) FXTHP6NLSSNF*** Harness MTP* (male) to duplex LC, OM3, 12-fiber, flat plenum jacket 0.50dB Max. IL per mated MTP* 0.25dB Max. IL per mated LC 1 Type A (1-1 wiring) 1.00dB plus cable attenuation (3.5dB per Km) MPO Fiber Adapter Panel (FAP) FAPH0612BLMPO or FQMAP65BL 6-port MTP*/MPO Adapter FAP (Opticom Style) or 6-port MTP*/MPO Adapter SFQ FAP NA – dependent on connector 2 Type A Interconnect or Trunks FXTRP5N5NANF*** or FXWSP5E5EAAF*** Interconnect MTP*- MTP* (female); OM3, 12-fiber round cable with plenum jacket or Trunk MTP*- MTP* (Female); OM3, 48-fiber cable with indoor plenum jacket 0.50dB Max. IL per mated MTP* 1 Type A Harness (End 2) FXTHP6NLSTNF*** Harness MTP* (Male) to duplex LC; OM3, 12-fiber, flat plenum jacket 0.50dB Max. IL per mated MTP* 0.25dB Max. IL per mated LC 1 Type A (Pair-flipped wiring)
7

TECHNICAL REFERENCE TR 113 Panduit Link Scenarios Method A ... · Panduit Link Scenarios . Method A Guidelines for Typical Multimode Duplex Signals . ... Method A Link with OM3 Fiber

Apr 21, 2018

Download

Documents

buitram
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: TECHNICAL REFERENCE TR 113 Panduit Link Scenarios Method A ... · Panduit Link Scenarios . Method A Guidelines for Typical Multimode Duplex Signals . ... Method A Link with OM3 Fiber

web: www.panduit.com e-mail: [email protected] phone: 800-777-3300 page 1

T E C H N I C A L R E F E R E N C E T R 1 1 3

*MTP is a registered trademark of US Conec Ltd.

Panduit Link Scenarios Method A Guidelines for Typical Multimode Duplex Signals

10G Ethernet and Fibre Channel Applications (OM3 Fiber with Standard Loss)

Method A Link with OM3 Fiber and Standard Loss - 2 Harness Design

Method A Link with OM3 Fiber and Standard Loss – 2 Harness Design Component Description Part Number Description Standard Insertion Loss Quantity Polarity Total Link Loss

Harness (End 1) FXTHP6NLSSNF*** Harness MTP* (male) to duplex LC, OM3, 12-fiber, flat plenum jacket

0.50dB Max. IL per mated MTP* 0.25dB Max. IL per mated LC 1 Type A

(1-1 wiring)

1.00dB plus cable attenuation (3.5dB per Km)

MPO Fiber Adapter Panel (FAP)

FAPH0612BLMPO or FQMAP65BL

6-port MTP*/MPO Adapter FAP (Opticom Style) or 6-port MTP*/MPO Adapter SFQ FAP

NA – dependent on connector 2 Type A

Interconnect or Trunks

FXTRP5N5NANF*** or FXWSP5E5EAAF***

Interconnect MTP*- MTP* (female); OM3, 12-fiber round cable with plenum jacket or Trunk MTP*- MTP* (Female); OM3, 48-fiber cable with indoor plenum jacket

0.50dB Max. IL per mated MTP* 1 Type A

Harness (End 2) FXTHP6NLSTNF*** Harness MTP* (Male) to duplex LC; OM3, 12-fiber, flat plenum jacket

0.50dB Max. IL per mated MTP* 0.25dB Max. IL per mated LC 1 Type A

(Pair-flipped wiring)

Page 2: TECHNICAL REFERENCE TR 113 Panduit Link Scenarios Method A ... · Panduit Link Scenarios . Method A Guidelines for Typical Multimode Duplex Signals . ... Method A Link with OM3 Fiber

web: www.panduit.com e-mail: [email protected] phone: 800-777-3300 page 2

T E C H N I C A L R E F E R E N C E T R 1 1 3

*MTP is a registered trademark of US Conec Ltd.

Method A Link with OM3 Fiber and Standard Loss - 1 Harness and 1 Cassette Design

Method A Link with OM3 Fiber and Standard Loss - 1 Harness and 1 Cassette Design Component Description Part Number Description Standard Insertion Loss Quantity Polarity Total Link

Loss

Harness (End 1) FXTHP6NLSSNF*** Harness MTP* (male) to duplex LC, OM3, 12-fiber, flat plenum jacket

0.50dB Max. IL per mated MTP* 0.25dB Max. IL per mated LC 1 Type A

1.25dB plus cable attenuation (3.5dB per Km)

MPO Fiber Adapter panel (FAP)

FAPH0612BLMPO or FQMAP65BL

6-port MTP*/MPO Adapter FAP (Opticom Style) or 6-port MTP*/MPO Adapter SFQ FAP

NA – dependent on connector 1 Type A

Interconnect or Trunks

FXTRP5N5NANF*** or FXWSP5E5EAAF***

Interconnect MTP*- MTP* (female); OM3, 12-fiber round cable with plenum jacket or Trunk MTP*- MTP* (female); OM3, 48-fiber cable with indoor plenum jacket

0.50dB Max. IL per mated MTP* 1 Type A

Cassette (End 2)

FC2XN-24-10AS or FQXN-12-10AS

QuickNet Cassette (Opticom style); OM3; 24-fiber MTP* to duplex LC or SFQ Cassette, OM3; 12-fiber; MTP* to duplex LC

0.75dB Max. Link Loss 1 Type A

Patch Cord (End 2) FX2ERLCLCTNM*** Duplex LC – LC Patch Cord; OM3; with riser

jacket 0.25dB Max. IL per mated LC 1 A-A

Note: There is an alternative configuration for customers who prefer A-B duplex patch cords. In the above list, replace the End 2 Cassette with FC2XN-24-10AF or FQXN-12-10AF (Modified Method A; pair flipped), and replace the End 2 patch cord with FX2ERLNLNSNM*** (A-B polarity)

Page 3: TECHNICAL REFERENCE TR 113 Panduit Link Scenarios Method A ... · Panduit Link Scenarios . Method A Guidelines for Typical Multimode Duplex Signals . ... Method A Link with OM3 Fiber

web: www.panduit.com e-mail: [email protected] phone: 800-777-3300 page 3

T E C H N I C A L R E F E R E N C E T R 1 1 3

*MTP is a registered trademark of US Conec Ltd.

Method A Link with OM3 Fiber and Standard Loss - 2 Cassette Design

Method A Link with OM3 Fiber and Standard Loss - 2 Cassette Design Component Description Part Number Description Standard Insertion Loss Quantity Polarity Total Link

Loss Patch Cord (End 1) FX2ERLNLNSNM*** Duplex LC-LC patch cord; OM3; with riser jacket 0.25dB Max. IL. Per mated LC 1 A-B

1.50dB plus cable attenuation (3.5dB per Km)

Cassette (End 1 & End 2)

FC2XN-12-10AS or FQXN-12-10AS

QuickNet Cassette (Opticom style); OM3, 24-fiber MTP* to duplex LC or SFQ Cassette; OM3; 12-fiber MTP* to Duplex LC

0.75dB Max. Link Loss 1 Type A

Interconnect or Trunks

FXTRP5N5NANF*** or FXWSP5E5EAAF***

Interconnect MTP*- MTP* (female); OM3, 12-fiber round cable with plenum jacket or Trunk MTP*- MTP* (female); OM3, 48-fiber cable with indoor plenum jacket

0.50dB Max. IL per mated MTP* 1 Type A

Patch Cord (End 2) FX2ERLNLNTNM*** Duplex LC – LC Patch Cord; OM3; with riser

jacket 0.25dB Max. IL per mated LC 1 A-A

Page 4: TECHNICAL REFERENCE TR 113 Panduit Link Scenarios Method A ... · Panduit Link Scenarios . Method A Guidelines for Typical Multimode Duplex Signals . ... Method A Link with OM3 Fiber

web: www.panduit.com e-mail: [email protected] phone: 800-777-3300 page 4

T E C H N I C A L R E F E R E N C E T R 1 1 3

*MTP is a registered trademark of US Conec Ltd.

Modified Method A Link with OM3 Fiber and Standard Loss - 2 Cassette Design

Modified Method A Link with OM3 Fiber and Standard Loss - 2 Cassette Design Component Description Part Number Description Standard Insertion Loss Quantity Polarity Total Link

Loss Patch Cord (End 1& End 2) FX2ERLNLNSNM*** Duplex LC-LC patch cord; OM3; with riser jacket 0.25dB Max. IL. Per mated LC 2 A-B

1.50dB plus cable attenuation (3.5dB per Km)

Cassette (End 1)

FC2XN-24-10AS or FQXN-12-10AS

QuickNet Cassette (Opticom style); OM3, 24-fiber MTP* to duplex LC or SFQ Cassette; OM3; 12-fiber MTP* to Duplex LC

0.75dB Max. Link Loss 1 Type A

Interconnect or Trunks

FXTRP5N5NANF*** or FXWSP5E5EAAF***

Interconnect MTP*- MTP* (female); OM3, 12-fiber round cable with plenum jacket or Trunk MTP*- MTP* (female); OM3, 48-fiber cable with indoor plenum jacket

0.50dB Max. IL per mated MTP* 1 Type A

Cassette (End 2)

FC2XN-24-10AF or FQXN-12-10AF

QuickNet Cassette (Opticom style) OM3, 24-fiber MTP* to duplex LC or SFQ Cassette; OM3, 12-fiber MTP to duplex LC

0.75dB Max Link Loss 1 Modified A; pair-flipped

Note: By incorporating a Modified Method A Cassette into this link design, the use of A-B patch cords is uniform at each end and an A-A patch cord is not required.

Page 5: TECHNICAL REFERENCE TR 113 Panduit Link Scenarios Method A ... · Panduit Link Scenarios . Method A Guidelines for Typical Multimode Duplex Signals . ... Method A Link with OM3 Fiber

web: www.panduit.com e-mail: [email protected] phone: 800-777-3300 page 5

T E C H N I C A L R E F E R E N C E T R 1 1 3

*MTP is a registered trademark of US Conec Ltd.

Method A Link with OM3 Fiber and Standard Loss - 2 Harness and 2 Cassette Design

Method A Link with OM3 Fiber and Standard Loss - 2 Harness and 2 Cassette Design Component Description Part Number Description Standard Insertion Loss Quantity Polarity Total Link

Loss Harness (End 1) FXTHP5NLSSNF*** Harness MTP* (Female) to duplex LC, OM3, 12-

fiber, flat plenum jacket 0.50dB Max. IL. per mated MTP* 0.25dB Max. IL. per mated LC 1 Type A

(1-1 Wiring)

2.00dB plus cable

attenuation (3.5dB per

Km)

Cassette (Cross Connect)

FC2XN-24-10AS or FQXN-12-10AS

QuickNet Cassette (Opticom style); OM3, 24-fiber MTP* to duplex LC or SFQ Cassette; OM3; 12-fiber MTP* to Duplex LC

0.75dB Max. Link Loss 2 Type A

Patch Cord (Cross Connect) FX2ERLNLNSNM*** Duplex LC-LC patch cord, OM3 with riser jacket 0.25dB Max. per mated LC 1 A-B

Interconnect or Trunks

FXTRP5N5NANF*** or FXWSP5E5EAAF***

Interconnect MTP*- MTP* (female); OM3, 12-fiber round cable with plenum jacket or Trunk MTP*- MTP* (female); OM3, 48-fiber cable with indoor plenum jacket

0.50dB Max. IL per mated MTP* 1 Type A

MPO Fiber Adapter Panel (FAP)

FAPH0612BLMPO or FQMAP65BL

6-port MTP*/MPO adapter FAP (Opticom Style) or 6-port MTP*/MPO adapter SFQ FAP

NA – dependent on connector 1 Type A

Harness (End 2) FXTHP6NLSSNF*** Harness MTP* (Male) to duplex LC, OM3, 12-

fiber, flat plenum jacket 0.50dB Max. IL. per mated MTP* 0.25dB Max. IL. per mated LC 1 Type A

(1-1 Wiring)

Page 6: TECHNICAL REFERENCE TR 113 Panduit Link Scenarios Method A ... · Panduit Link Scenarios . Method A Guidelines for Typical Multimode Duplex Signals . ... Method A Link with OM3 Fiber

web: www.panduit.com e-mail: [email protected] phone: 800-777-3300 page 6

T E C H N I C A L R E F E R E N C E T R 1 1 3

*MTP is a registered trademark of US Conec Ltd.

Method A Link with OM3 Fiber and Standard Loss – 1 Harness and3 Cassette Design

Method A Link with OM3 Fiber and Standard Loss - 1 Harness and 3 Cassette Design Component Description Part Number Description Standard Insertion Loss Quantity Polarity Total Link

Loss Harness (End 1) FXTHP6NLSSNF*** Harness MTP* (Male) to duplex LC, OM3, 12-

fiber, flat plenum jacket 0.50dB Max. IL. per mated MTP* 0.25dB Max. IL. per mated LC 1 Type A

(1-1 Wiring)

2.00dB plus cable

attenuation (3.5dB per

Km)

MPO Fiber Adapter Panel (FAP)

FAPH0612BLMPO or FQMAP65BL

6-port MTP*/MPO adapter FAP (Opticom Style) or 6-port MTP*/MPO adapter SFQ FAP

NA – dependent on connector 1 Type A

Interconnect or Trunks

FXTRP5N5NANF*** or FXWSP5E5EAAF***

Interconnect MTP*- MTP* (female); OM3, 12-fiber round cable with plenum jacket or Trunk MTP*- MTP* (female); OM3, 48-fiber cable with indoor plenum jacket

0.50dB Max. IL per mated MTP* 2 Type A

Cassette (Cross Connect & End 2)

FC2XN-24-10AS or FQXN-12-10AS

QuickNet Cassette (Opticom style); OM3, 24-fiber MTP* to duplex LC or SFQ Cassette; OM3; 12-fiber MTP* to Duplex LC

0.75dB Max. Link Loss 3 Type A

Patch Cord (Cross Connect & End 2)

FX2ERLNLNSNM*** Duplex LC-LC patch cord, OM3 with riser jacket 0.25dB Max. per mated LC 2 A-B

Page 7: TECHNICAL REFERENCE TR 113 Panduit Link Scenarios Method A ... · Panduit Link Scenarios . Method A Guidelines for Typical Multimode Duplex Signals . ... Method A Link with OM3 Fiber

web: www.panduit.com e-mail: [email protected] phone: 800-777-3300 page 7

T E C H N I C A L R E F E R E N C E T R 1 1 3

*MTP is a registered trademark of US Conec Ltd.

Method A Link with OM3 Fiber and Standard Loss - 4 Cassette Design

Method A Link with OM3 Fiber and Standard Loss - 4 Cassette Design Component Description Part Number Description Standard Insertion Loss Quantity Polarity Total Link

Loss Patch Cord (End 1, Cross Connect & End 2

FX2ERLNLNSNM*** Duplex LC-LC patch cord, OM3 with riser jacket 0.25dB Max. per mated LC 3 A-B

2.00dB plus cable

attenuation (3.5dB per

Km)

Cassette (End 1, Cross Connect & End 2)

FC2XN-24-10AS or FQXN-12-10AS

QuickNet Cassette (Opticom style); OM3, 24-fiber MTP* to duplex LC or SFQ Cassette; OM3; 12-fiber MTP* to Duplex LC

0.75dB Max. Link Loss 4 Type A

Interconnect or Trunks

FXTRP5N5NANF*** or FXWSP5E5EAAF***

Interconnect MTP*- MTP* (female); OM3, 12-fiber round cable with plenum jacket or Trunk MTP*- MTP* (female); OM3, 48-fiber cable with indoor plenum jacket

0.50dB Max. IL per mated MTP* 2 Type A